American Power Conversion MasterSwitch Switch User Manual
Contents
1. In addition if you want to use SNMP to configure and control the MasterSwitch you will need to load and compile APC s Master Switch MIB at any network management station NMS you will use for SNMP control of the MasterSwitch NOTE The MasterSwitch MIB is provided on the diskette that came with the MasterSwitch See the documentation for the NMS you want to use this MIB for instructions on loading and compiling MIBs 7 Operation Check After the MasterSwitch is installed and set up 1 Confirm that the network connection status Link and Status LEDs are on lit 2 Confirm that all eight of the receptacle status LEDs are on lit 8 Troubleshooting No power from any Blown MasterSwitch circuit Reset circuit breaker or receptacle breaker or no input power correct input power problem Network connection LEDs Connection to network is Make sure network cable is do not come on faulty securely connected to the MasterSwitch and network Circuit breaker Amps drawn by load Lim it load equipment to those continuously or frequently equipment exceeds 15 amp devices which together draw trips maximum less than 15 amps Table 2 Troubleshooting If the MasterSwitch requires service 1 Check the MasterSwitch using the troubleshooting chart in section 6 before calling for service 2 Note the model number of the MasterSwitch the serial number and the date purchased See the back cover o
2. AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAM AGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Life Support Policy As a general policy American Power Conversion APC does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness APC does not recommend the use of any of its products in direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances Examples of devices considered to be life support devices are neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dia
3. AMERICAN POWER CONVERSION Thank You Thank you for selecting the MasterSwitch network manageable power distribution unit PDU The MasterSwitch has been designed for many years of reliable maintenance free service in combination with your American Power Conversion APC Uninterrupt ible Power Source UPS APC is dedicated to the development of high performance electrical power conversion and control products and we hope that you will find this product a valuable convenient addition to your computing system Please read this manual It provides important safety installation and operating instructions that will help you get the most from your MasterSwitch Save this manual It includes instructions for obtaining factory service should the proper operation of the MasterSwitch come into question Radio Frequency Interference WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment FCC Statement NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the inst
4. C 15 Amp outlet 4 Refer to Section 4 for information on setting up the MasterSwitch aN Rack Mount Installation To mount the MasterSwitch in a NetShelter or other 19 inch NEMA rack 1 Peel the rubber feet from the bottom of the MasterSwitch 2 Refer to Figure 3 and use a 2 Phillips head screwdriver and two of the supplied screws to attach each mounting bracket to the MasterSwitch NOTE The mounting brackets can be attached at various positions along the side of the chassis Choose a position that will not cause the mounted MasterSwitch or attached cables to interfere with closing the cabinet door or to otherwise protrude from the cabinet If more than two mounting holes are aligned choose the pair that are farthest apart Figure 3 Attaching Mounting Brackets 3 Refer to Figure 4 and use 4 cage nuts and machine screws not supplied with the MasterSwitch to mount the MasterSwitch into the NetShelter cabinet TM If the MasterSwitch is being installed in a cabinet other than a NetShelter use the hardware that is appropriate for the cabinet 4 Plug the male end of your network interface cable not supplied with the MasterSwitch into the RJ45 jack on the front of the MasterSwitch 5 Plug the MasterSwitch power cord into a single phase 120 VAC 15 Amp outlet 6 Refer to Section 4 for information on setting up the MasterSwitch Ll putar
5. LAN e Two LEDs Link and Status for monitoring the network connection e Eight LEDs one for each receptacle to report power on lit or off not lit conditions of the MasterSwitch power outlets TM e A reset button that reinitializes the MasterSwitch without affecting its outlet power warm reboot Reset Network Button Status LEDs Configuration NE of Port 10 Base T Network Port Receptacle Status LEDs Figure 2 MasterSwitch Front Panel 2 Package Contents In addition to this installation guide the MasterSwitch also comes with the following items e Two rack mounting brackets TM Four screws for attaching the rack mounting brackets to the MasterSwitch One 9 pin male to 9 pin female cable APC PN 940 0103 for connecting a terminal or terminal emulator to the MasterSwitch for configuration TM One diskette which contains a pdf formatted copy of the MasterSwitch User s Guide pduguide pdf as well as a copy of the MasterSwitch manage ment information base MasterSwitch MIB that provides the object identifiers OIDs needed to use an SNMP browser to monitor and control the Master TM Switch One copy of the warranty card Note Please fill out and return the warranty card This card not only provides us with valuable welcomed feedback on how we can refine our products to better serve your needs but it also enables us to notify you about important product
6. e COHN Entire contents copyright 1997 American Power Conversion All rights reserved reproduction in whole or in part without permission is prohibited MasterSwitch NetShelter and PowerNet are trademarks of APC All other trademarks are the property of their respective owners 1 Introduction The MasterSwitch is a network manageable intelligent power distribution unit PDU designed to provide control of power for up to eight 120 VAC electrical devices The MasterSwitch allows you to e Individually control each of eight outlets using a web browser an SNMP browser or a terminal program e Remotely and individually reboot hung servers e Remove power to non essential loads e Sequentially apply power to equipment plugged into the MasterSwitch As shown in Figure 1 the MasterSwitch e Has a 15 foot attached input line cord e Has eight 120 VAC 15 Amp power receptacles 4 x NEMA 5 15 e Has a 15 Amp circuit breaker TM Figure 1 MasterSwitch with Rack Mounting Brackets and Configuration Cable As shown in Figure 2 the MasterSwitch also features e A 9 pin configuration port for connecting the MasterSwitch to a terminal or terminal emulator during the setup procedures Section 4 This connection is made using the 9 pin cable APC PN 940 0103 that comes with the MasterSwitch TM e An 8 pin RJ45 jack for connecting the MasterSwitch to a 10Base T Local Area Network
7. e eee TM Figure 4 Mounting in a NetShelter Cabinet 5 Status Indicators The MasterSwitch has eight receptacle status LEDs located on the front panel When a status LED is on it indicates the related recep tacle has power When a status LED is off its receptacle does not have power The MasterSwitch also has two network connection status LEDs also located on the front panel that indicate the following states C E Blinking M asterSwitch is connected to a working Link TX R X Green network Network or MasterSwitch connection failure M asterSwitch is ok Blinking Network configuration values have not been Green i i Status defined for the MasterSwitch Flashing Processing bootp Red Slow Solid Red Hardware Failure Table 1 Network Connection 10Base T Status Indicators 6 Initial Setup TM Before the MasterSwitch can operate over the network it needs to have certain address values defined These values can be set config ured by a BOOTP server the MasterSwitch comes with BOOTP enabled or by using a terminal or terminal emulator connected to TM the 9 pin configuration port on the front panel of the MasterSwitch NOTE Refer to the MasterSwitch User s Guide for information on the initial configuration of the MasterSwitch A copy of this guide in portable data format is provided on the diskette that came with the MasterSwitch
8. er Conversion Corpora tion 4 Rue St Claire Deville Lognes F 77185 France American Power Conversion Corpora tion Omodaka Bldg 5F 1 9 7 Shibaura Minato ku Tokyo 105 Japan Entire contents copyright 1997 American Power Conversion All rights reserved reproduction in whole or in part without permission is prohibited MasterSwitch NetShelter and PowerNet are trademarks of APC All other trademarks are the property of their respective owners Rev 1 0
9. f this manual for the correct telephone number and call customer service A technician will ask you to describe the problem and help solve it over the phone if possible or will give you an RMA If customer service is not available in your area call the dealer that sold the MasterSwitch If it is under warranty repairs are free If not there will be a charge for repair 3 It is important to pack the MasterSwitch properly to avoid damage in transit If possible use the original packing materials Damage sustained in transit is not covered under warranty 4 Include a letter with your name RMA address copy of the sales receipt description of the trouble your daytime phone number and a check if necessary 5 Mark the RMA on the outside of the package The factory cannot accept any package without this marking 6 Return the MasterSwitch by insured prepaid carrier to the address given by the technician 10 Specifications Input Nominal input voltage 120 VAC Acceptable input voltage 100 140 VAC Nominal input frequency 50 60 Hz Overcurrent protection 15 A resettable circuit breaker Input connector 15 foot 4 5 m attached NEMA 5 15 line cord Output Output connectors 8 NEMA 5 15 receptacles Size H x W x D without mounting brackets 2 125 x 17 x 6 5 inches 5 4 x 43 2 x 16 5cm with mounting brackets 1 875 x 19 x 6 5 inches 4 8 x 48 3 x 16 5cm 6 5 Ib 3 0 kg Shipping weight 10 0 Ib 4 5
10. kg Operating elevation storage 0 to 3 000 m 0 to 15 000 m Operating temperature storage 0 to 40 0 to 45 foo UT CsCSY scala laa Ln Table 3 MasterSwitch Specifications TM Limited Warranty American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from APC or an APC service center Products must be returned to APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT
11. lysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators and infusion pumps as well as any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care AMERICAN POWER CONVERSION Toll free technical support Addresses United States and Canada 1 800 800 4272 International Austria Belgium Denmark Finland France Germany Holland Treland Israel Italy Japan Norway Portugal Russia South Africa Spain Sweden Switzerland Turkey UK In areas without toll free numbers 0660 6480 0800 15063 800 18 153 9800 13 374 0 800 09 24 07 0130 818907 0602 24655 1 800 702000 177 353 2206 1678 74731 0120 80 60 90 800 11 632 050 553182 7095 230 6297 0800 994206 900 95 35 33 020 795 419 1556 177 0800 35390275 0800 132990 1 401 789 5735 USA or 353 91 702020 Ireland Serial number MAC Address 990 0154 American Power Conversion Corpora tion 132 Fairgrounds Road P O Box 278 West Kingston RI 02892 USA American Power Conversion Corpora tion A P C b v Ballybritt Business Park Galway Ireland American Pow
12. ruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Canadian Department of Communications Statement This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Depart ment of Communications Le pr sent appareil num rique n emet pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dicte par le minist re d s Communications du Canada Contents NTL POGUC TON casacesccrcsotnconsersecccesectseonatereesseeatcn Package Contents wcrcesccntcrsancisctersnmtscestnateesdes On line Documentation ssoseeseeoeeeeeeeneennenn Installation ee e e Desktop Installation sic teietescscecesccecmensscueceenmeuceciecimgendes Rack Mount Installation cccecssseceeceeeesseeeeeeeeee Status Indicators wa cessasassacevteccertesteoveren dda ic Initial Setup seeecgonoantesceneaeunsvuncsienandneeencseste Operation Check ccccsssssssseeeeeeeeeeeeeeeeees Troubleshooting eevee eccdacstheeseeenecenccennt seen no Bd C Mente anne ane ame ee eee ee Specifications ss scccaiwatveeccnesienttacseaswneaweredecens pe I
13. updates and changes Release notes may also be included to advise you of any information that has become relevant since this installation guide and the on line user s guide included on the diskette were last revised 3 On line Documentation The diskette that comes with the MasterSwitch includes a copy of the MasterSwitch User s Guide in portable data format pduguide pdf This guide can be read using Acrobat Reader a free application available from Adobe http www adobe com If you do not have web capabilities a copy of this guide is available from APC s FTP site apccorp apcc com 4 Installation The MasterSwitch which connects to a 10Base T Local Area Network LAN through the RJ45 jack on the front of the unit can be used as a freestanding desktop unit or mounted in a NetShelter cabinet or other 19 NEMA rack Desktop Installation The MasterSwitch is equipped with rubber feet for desktop use and can be located wherever space permits 1 Place the MasterSwitch in its permanent location Make sure that this location is within 15 feet 4 6 meters of a single phase 120 VAC 15 Amp outlet and that the back of the unit receptacle side will be readily accessible 2 Plug the male end of your network interface cable not supplied with the MasterSwitch into the RJ45 jack on the front of the MasterSwitch 3 Plug the MasterSwitch power cord into the single phase 120 VA