American Power Conversion AP9615 Switch User Manual
Contents
1. Power Input voltage range 18 30 VDC Maximum current draw 45 mA Physical Size H x W x D 1 46 x 4 75 x 4 30 in 3 7 x 12 1 x 10 9 cm Weight 0 25 Ib 0 11 kg Shipping weight Environmental 0 65 Ib 0 30 kg Elevation above MSL Operating Storage Temperature Operating Storage 0 to 10 000 ft 0 to 3000 m 0 to 50 000 ft 0 to 15 000 m 32 to 122 F 0 to 50 C 5 to 158 F 15 to 70 C Relative humidity Operating Storage 0 to 95 non condensing 0 to 95 non condensing Approvals Standards FCC Part 15 Class B EN 55 022 CISPR 22 Class B VCCI Class 2 IEC 1000 4 2 3 4 CE C Tick IEEE 802 3 10Base T Port Configuration Station Ports are MDI X Uplink port is MDI Table 3 Product Specifications 14 Warranty Information Limited warranty Warranty registration Warranty limitations American Power Conversion APC warrants the 5 Port 10Base T Hub to be free from defects in materials and work manship for a period of 2 years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective prod ucts This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser To register your product with
2. 5735 USA or 353 91 702020 Ireland 7095 916 7166 Russia Serial number 2 30 4 Nishi gotanda Shinagawa ku Tokyo 141 Japan APC Europe 143 Bis Avenue de Verdun 92442 Issy les Moulineaux Cedex France Entire contents copyright 1999 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited All trademarks are the property of American Power Conversion 990 0324 7 99
3. APC visit our Warranty Regis tration Web page http www apcc com support warranty Except as provided herein American Power Conversion makes no warranties express or implied including warran ties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equip ment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty Information continued Obtaining service 16 To obtain service for your 5 Port 10Base T Hub follow this procedure 1 Note the serial number and date of purchase of the hub The serial number is located on the top interior surface of the hub s front panel Contact APC Customer Support at the phone number or address on the back cover of this manual Be prepared to provide a description of the problem A technician will help solve the problem o
4. Business Park Galway Ireland UPS Accessory Equipment AP9615 RA9901D00000 RA0001D99999 1999 2000 We the undersigned hereby declare that the equipment specified above conforms to the above directives St Louis MO USA June 24 1999 An lat Place Date Ted Eckert Regulatory Compliance Engineer Galway Ireland June 24 1999 Z A fae Place Date Ray Ballard General Manager Galway www apcc com Toll free Customer Support E mail Customer Support U S amp Canada 1 800 800 4272 Australia anztech apcc com Austria 0660 6480 Europe apceurtech apcc com Belgium 0800 15063 India isbtech apcc com Czech Republic 0 800 102063 Japan jsupport apcc com Denmark 800 18 153 Latin America apctchla apcc com Finland 9800 13 374 SE Asia asetech apcc com France 0 800 906 483 Holland 0800 0224655 U S amp Canada __http support apcc com Hungary 00800 12221 Ireland 1 800 702000 x 2045 Addresses Israel 177 353 2206 American Power Conversion Corporation Italy 1678 74731 132 Fairgrounds Road Japan 0120 80 60 90 P O Box 278 Luxembourg 0800 2091 West Kingston Rhode Island 02892 Norway 800 11 632 USA Poland 00800 353 1202 Portugal 050 553182 APC Ireland South Africa 0800 994206 A P C b v Spain 900 95 35 33 Ballybritt Business Park Sweden 020 795 419 Galway Switzerland 0800 556177 Ireland Turkey 0800 35390275 APC Japan UK 9809 Sane BR Gotanda 7 Floor Areas without toll free numbers 1 401 789
5. xo X Uain Paa straight through cable crossover cable Figure 4 Cascading Hubs in a Star Configuration 10 Removing the Hub Removal To remove the 5 Port 10Base T Hub perform the following procedure steps in the order given 1 Disconnect all cables from the hub 2 Turn off the UPS or device that houses the hub For detailed instructions see Installation procedure on page 5 3 Use a 2 Phillips head screwdriver to remove the 2 screws fastening the hub to the UPS or triple chassis Keep the screws for Step 6 below 4 Carefully grasp the sides of the hub s front panel and gently pull the hub from the SmartSlot panel Do not touch the exposed printed cir cuit board or components Touching the circuit board or components may result in damage to the hub Handle the 5 Port 10Base T Hub by the front 5 Place the hub into its original packaging or other static safe material 6 Replace the SmartSlot coverplate removed during installation of the hub with the screws removed in Step 3 Troubleshooting Troubleshooting suggestions 12 Table 2 provides suggestions for troubleshooting your hub Action Cause Solution Blinking Normal data collisions on the network No action is necessary Blinking Data collisions are occurring because of a high volume of traffic on the network excessiv
6. 5 Port 10Base T Hub AP9615 Thank You Thank you for selecting the APC SmartSlot 5 Port 10Base T Hub AP9615 It has been designed for many years of reliable maintenance free service in combination with your American Power Conversion APC uninterruptible power supply UPS APC is dedi cated to the development of high performance electrical power conversion and control products We hope that you will find this product a valuable convenient addition to your computing system Please read this manual It provides important safety installation and operating instruc tions that will help you get the most from your SmartSlot hub Save this manual It includes instructions for obtaining warranty service Radio frequency interference WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communica tions However there is no guarantee that interference will not occur in a particular installa
7. ase T Hub Hardware requirements The SmartSlot 5 Port 10Base T Hub is an APC accessory that allows you to expand or create a local area network LAN by installing it in the SmartSlot of an APC UPS or expansion chassis The following list shows some of the features of the 5 Port 10Base T Hub Your hub Installs easily into any SmartSlot equipped APC UPS or expansion chassis thus minimizing clutter Has 4 station ports and 1 uplink port Can be used to create a stand alone 5 station 10Base T network or can expand an existing 10Base T network by 4 stations Is powered by the host APC UPS or accessory Has LEDs that show information on the hub s power status and the presence of data collisions Has LEDs on each port that indicate the presence of traffic link and partitioning The 5 Port 10Base T Hub requires An APC UPS or expansion chassis with an available SmartSlot A configured 10Base T port for each device to be attached An unshielded twisted pair UTP communication cable for each device to be attached See Communication cables on page 4 for more information Product Description Front panel APC Communications Compatibility Number This figure shows the front panel of the 5 Port 10Base T Hub The features of the front panel are described in the paragraphs that follow APC Communications Compatibility Number m Collision LED Upl
8. ected device is good Blinking The port is receiving data Partition Yellow The port has been partitioned because of an excessive frequency of collisions The partition condition will automatically clear when the connected device begins operating properly Table 1 Description of LEDs Continued on next page Product Description continued Station ports The Station ports are the first 4 RJ 45 ports which are labeled 1X 4X The Station ports use straight through UTP cables to connect the hub with e Workstations or other non hub devices that you want to include in your network e The Uplink port of another hub in a cascading config uration Note A Station port acts as an Uplink port when it is used with a crossover cable Uplink port The Uplink port is normally used in either of the following ways as shown in Figure 2 o To 2 Corporate LAN La ete x zx eink 1X ae Jt as Uplink ao pA in Lt E B E E m im BE TE ty E m m i l L a E ae a l iL tf straight through cable crossover cable Figure 2 Dual Use of the Uplink Port Connected in cascade with a Station port of another hub or switching device using a straight through cable Connected to a workstation or other non hub device using a crossover cable Communication The hub requires a category 3 4 or 5 UTP 10Base T co
9. ely Make sure connected devices are not operating in full duplex mode they must operate in half duplex mode Segment the network with an Ethernet switch Cables used to connect to the network are defective or of the wrong type Verify that the cable is of the correct type See Communication cables on page 4 for more information Link Traffic Off even with a cable attached Successful link is not being detected by the port Verify that the hub and the connected device are powered Verify that the cable is of the correct type See Communication cables on page 4 for more information Inspect cables for damage cable pairs to see if they are wired correctly and connectors to see if they are loose Table 2 Suggestions for Troubleshooting Continued on next page Troubleshooting continued Troubleshooting suggestions continued Solution 32 consecutive collisions have caused the port to partition Partition Check that the correct cable is in use and verify that the connected equipment is set to operate at 10 Mbit and half duplex mode As collisions reduce the port reconnects and the Partition LED turns off Table 2 Suggestions for Troubleshooting continued 13 Specifications Product specifications 5 Port 10Base T Hub The following table shows the product specifications for the Item Specification
10. he hub all the way into the slot until its front panel is flush with the back panel of the UPS or triple chassis Observe the correct orientation as shown in Figure 3 Note that the sides of the circuit board align with the card guides of the SmartSlot Note While it is not possible to install the hub upside down it is possible to damage the unit in the attempt to do so Figure 3 Orient the hub to fit into the SmartSlot Continued on next page Installing the Hub continued Installation 5 Secure the hub with the screws removed in Step 3 procedure 6 Using straight through UTP cables connect the Sta continued tion ports 1X 4X in any order to each worksta tion s 10Base T port or to the Uplink port of a hub to be connected in cascade See Figure 2 on page 4 7 Connect the Uplink port if applicable If connecting to another hub Use a straight through cable to connect to a Sta tion port See Figure 2 on page 4 Use a crossover cable to connect to the Uplink port See Figure 4 on page 10 If connecting the Uplink port to a workstation or other non hub device Use a crossover cable See Figure 2 on page 4 8 Turn on the UPS or device that now houses the hub To turn on the UPS or device follow the appropriate procedure listed below Smart UPS a Plug the UPS back into the AC power outlet b Press and hold the Power On button until you hear a click and beep or until the power LED illumi
11. ink port Station ports Power LED he Link Traffic Partition 15 1x 2X 3X 4X Uplink L i amr 4 if Hoar H aa D 0 Fra C coa A FLLEELIILE LLLELIE LLLP Pir Smart Slot AP9615 5 Port 10Base T Hub wWww apce com N Link Traffic LED Partition LED r 65 Figure 1 Front Panel and Connector Detail The APC Communications Compatibility Number CCN which appears on the upper left corner of the front panel refers to the ability of an accessory to work with other APC products The CCN for your hub may be different from the example shown in Figure 1 In general we strive to make all APC products compatible with one another however if you want specific information on the compatibility of the 5 Port 10Base T Hub with APC UPSs and accessories visit the APC support page http www apcc com support kbase and search for Communications Compatibility Number Continued on next page Product Description continued LEDs The LEDs provide important information concerning opera tion of the hub and each of its ports Refer to the table below for a description of the conditions indicated by LEDs Activity Description The hub is receiving power Yellow Blinking The network is experiencing data collisions Note that occasional collisions are normal Link Traffic On The link between the port and the conn
12. ion procedure continued Matrix UPS a Shut down and power off the connected equipment b Turn off the circuit breaker on the bottom left side on the back panel of the UPS S ymmetra Power Array a Shut down and power off the connected equipment b Turn off the System Enable switch on the bottom left side on the back panel of the UPS Smart UPS DP a Shut down and power off the connected equipment b Turn off the ON OFF switch on the front panel Triple Chassis for Silcon DP300E Series UPSs a Shut down and power off the connected equip ment b If present unplug the Triple Chassis s power supply from the AC power outlet c Disconnect the cable attached to the To UPS port on the Triple Chassis 2 Unpack the 5 Port 10Base T Hub The shipping materials are recyclable Please save reuse or dis pose of them appropriately A Handle the 5 Port 10Base T Hub by the front panel Do not touch the exposed printed cir cuit board or components Touching the circuit board or components may result in damage to the hub Continued on next page Installing the Hub continued Installation 3 Use a 2 Phillips head screwdriver to remove the 2 procedure screws fastening the SmartSlot cover plate to the continued back panel of the UPS or triple chassis Keep the screws for Step 5 below Save the SmartSlot cover plate for future use e g shipping the UPS 4 Orient the hub to fit into the SmartSlot Slide t
13. m cables munication cable for each device to be attached 4 Installing the Hub Warning A Installing on critical systems Installation procedure Do not operate the 5 Port 10Base T Hub where conditions are outside the limits listed in Product Specifications on page 14 The installation procedure that follows may involve shut ting off power from the UPS However if your setup requires maintaining power to connected equipment throughout installation visit the support page on our Web site http www apcc com support kbase and follow the appropriate procedure in Installation Instructions for APC Management Accessories on Critical Systems To install the 5 Port 10Base T Hub perform the following steps in the order given Note The Smart UPS Matrix UPS Symetra Power Array Smart UPS DP and Triple Chassis for Silcon require different procedures to turn off the UPS or device that will host the hub 1 To turn off the UPS or device that will host the hub follow the appropriate procedure listed below Smart UPS a Shut down and power off the connected equip ment b Press and hold the UPS s Power Off button until you hear a click or until the UPS s power LED extinguishes c Unplug the UPS from the AC power outlet d Press and hold the UPS s Power Off button until you hear a click hold for at least 5 sec onds Continued on next page Installing the Hub continued Installat
14. nates c Power on the connected equipment Matrix UPS a Turn on the circuit breaker on the bottom left side on the back panel of the UPS b Turn on the UPS via the front panel c Power on the connected equipment Continued on next page Installing the Hub continued Installation Symmetra Power Array procedure a Turn on the System Enable switch on the continued bottom left side on the back panel of the UPS b Turn on the UPS via the PowerView display c Power on the connected equipment Smart UPS DP a Turn on the ON OFF switch on the front panel b Power on the connected equipment Triple Chassis for Silcon DP300E Series UPSs a Attach the cable to the To UPS port on the Tri ple Chassis b If applicable plug the Triple Chassis s power supply into the AC power outlet c Power on the connected equipment Continued on next page Installing the Hub continued Maximum Using a star configuration you can cascade up to ten 5 Port configuration 10Base T hubs together to provide network connections for as many as 32 stations as shown below in Figure 4 Note the use of a crossover cable to connect the Uplink ports of the 2 central hubs 1X x E ake velit Sei 1X 2X 3 4X Uplink SASAE S S il Ds i L mo a Ht L OX
15. tion If this equipment does cause harmful interference to radio or television recep tion which can be determined by turning the equipment off and on try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio or TV technician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Contents Introduction i ohicracasaaouiacaaas a ata an Monae ee aan ae 1 Overview 1 Features of the 5 Port 10Base T Hub 1 Hardware requirements 1 Product Description ccc cece eee ees 2 Front panel 2 APC Communications Compatibility Number 2 LEDs 3 Station ports 4 Uplink port 4 Communication cables 4 Installing the Hub 1 00sec eee 5 Warning 5 Installing on critical systems 5 Installation procedure 5 Maximum configuration 10 Removal procedure 11 Troubleshooting 0c eect eee eee 12 Troubleshooting suggestions 12 Product specifications 14 Warranty Information 0 0000 cece eee es 15 Limited warranty 15 Warranty registration 15 Warranty limitations 15 Obtaining service 16 Introduction Overview Features of the 5 Port 10B
16. ver the phone if possible or will give you a return material authorization RMA number If the hub is under warranty repair or replacement is free of charge If the warranty has expired there will be a nominal charge for repair or replacement Pack the hub carefully in its original packaging if possible Do not use polystyrene beads for packing Damage sustained in transit is not covered under the warranty Enclose a letter in the package with your name address RMA number a copy of the sales receipt daytime phone number and check if applica ble Mark the RMA number clearly on the outside of the shipping carton The service center will not accept any materials without this marking Return the hub by insured prepaid carrier to the address given to you by APC Customer Support Declaration of Conformity Application of Council Directives Standards to Which Conformity is Declared Manufacturer s Name and Address Importer s Name and Address Type of Equipment Model Numbers Serial Numbers Years of Manufacture 89 336 EEC EN55022 1995 Class B EN50082 1 1992 including TEC 1000 4 2 1995 TEC 1000 4 3 1995 TEC 1000 4 4 1995 FCC Part 15 Class B VCCI Class 2 American Power Conversion 132 Fairgrounds Road West Kingston Rhode Island 02892 USA or American Power Conversion A P C b v Ballybritt Business Park Galway Ireland American Power Conversion A P C b v Ballybritt