Home
Air King 9898L Fan User Manual
Contents
1. USING YOUR CEILING FAN 1 Restore power to the electrical box 2 Check the operation of the fan by gently pulling the chain switch 3 Toreverse airflow direction turn fan off and wait for the blades to come to a full stop then slide reversing switch to opposite position Figure 9 N Reversing Switch 4 Your ceiling fan is equipped with four position three speed pull chain switch MAINTENANCE Periodic cleaning of your ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to the finish Do not spray water directly onto your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock or fire WARRANTY The ceiling fan you have purchased is warranted by the manufacturer for one year from the date of purchase against defects in workmanship and or materials The motor is warranted for ten years This warranty means that only the parts that prove to be defective during the period of warranty will be either repaired or replaced at our option The right is reserved by the manufacturer to replace the whole product in lieu thereof Should repair become necessary during the warranty period write to AIR KING c o LASKO PRODUCTS INC Appliance Service Department 820 Lincoln Ave West Chester PA 19380 Describe th
2. turned off at the main fuse box before wiring cleaning or servicing b Fan should not be mounted in areas where it might come in direct contact with water RULES FOR SAFE OPERATION 1 Be careful of the fan and moving blades when cleaning painting or working near fan 2 Do not put anything into the blades while they are turning 3 Do not bend the blade brackets when installing the brackets balancing the blades or cleaning the fan 4 WARNING The fan must be hung with at least 7 feet of clearance from floor to blades INSTALLATION INSTRUCTIONS 1 Attach the hanger bracket to the electrical box capable of reliably supporting at least 50 pounds Insert the screws through the slotted holes in the bracket and attach to the electrical box Tighten both screws to the electrical box Figure 1 NOTE If bracket and or electrical box are not securely attached the fan could wobble Electrical Box p S Mounting Pa Bracket 1 Figure 1 2 Install motor leads through the canopy then through the hole in the center of the pipe flange Insert downrod into downrod yoke Make sure to align hole in downrod with hole in downrod yoke Lift canopy and install yoke cross pin through yoke and downrod Insert cotter pin into cross pin until it snaps into place Using a phillips head screwdriver firmly tighten set screws in yoke Figure 2 WARNING Failure to completely install the cotter pin or tighten the set screw could r
3. BLADE ASSEMBLY AND NOTE The blades should be attached to the fan after it is hung and wired to prevent blade brackets from being bent and causing the fan to wobble _ LS7 Remove the three shipping 8 stabilizer tabs from the Remove Remove bottom of the fan a a 1 Using three phillips washer head screws secure one bracket to each of the blades Complete this assembly before attaching blades to ceiling fan Figure 6 E Blade Bracket Phillips Washer Head Screw Screws Figure 6 2 Place one of the phillips pan head screws into one of the recessed holes in the blade bracket Turn screw until it mates with threaded hole in hub Do not tighten screw completely at this time Figure 7 3 Install the second screw in the same manner then tighten both screws firmly Motor Hub 4 Install the remaining blade assemblies by repeating the above Phillips Pan steps Head Screw Figure 7 1 Connect the black wire in the light fitter with the blue wire marked For Light using the supplied wire nuts Figure 8 2 Connect the white wire in the light fitter with the white wire marked For Light using the supplied wire nuts 3 Tuck the wires and wire nuts into switch cup Lift the light fitter into place and insert the three screws and tighten 4 Install light bulb not included and lift globe into place and secure with the three thumb screws Do not overtighten
4. e problem you are having DO NOT SEND FAN This warranty does not apply if the damage occurs because of accident improper handling installation or operation shipping damage abuse misuse or unauthorized repairs made or attempted ALL WARRANTIES EXPRESSED OR IMPLIED LAST FOR ONE YEAR FROM DATE OF ORIGINAL PURCHASE EXCEPT FOR THE MOTOR THIS WARRANTY DOES NOT COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER Some states do not allow limitations on how long any implied warranty lasts or the exclusion or limitations of incidental or consequential damages so that the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may have other rights that vary from state to state FOR REPLACEMENT PARTS Please call 1 800 966 2028 Monday Friday between the hours of 8am and 4 pm EST Reference the type and style of product when you call FOR QUESTIONS OR COMMENTS ABOUT YOUR CEILING FAN Please call 1 800 233 0268 Monday Friday between the hours of 8am and 4pm EST Figure 9 New 11 00 INSTRUCTION MANUAL Model 9898L Ventilation Products CHOTCE 52 PORCH CEILING FAN READ AND SAVE THESE Your new ceiling fan is UL listed and will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The 52 total fan weight is 26 Ibs maximum WARNING To reduce the risk of fire electrical shock or personal inju
5. esult in the fan loosening and possibly falling Cotter Pin N Yoke Cross Pin Set Screw Figure 2 3 Carefully lift the fan and seat the pipe flange and ball assembly on the hanger bracket that was just attached to the electrical box Be sure the notch on the side of the ball is lined up with tab on the hanger bracket Figure 3 WARNING Failure to seat tab on bracket into notch on ball could cause damage to electrical wires and cause fan to fall NOTE Do not pinch wires between the ball and pipe flange assembly and hanger bracket NOTE Ceiling canopy supply wires and fan wires omitted from figure for clarity Electrical Box Pipe Flange Assembly Figure 3 4 Make sure the electrical box is properly secured If romex cable plastic sheathed was used to wire the electrical box the presence of a third wire connected to the electrical box indicates that the box is grounded This ground wire may be bare wire no insulating jacket or a green insulated wire The two supply wires will be white and black insulated wires 5 Ifthe wiring to the electrical box is enclosed in electrical conduit pipe the ground wire may not be present The conduit itself could serve as the ground GROUNDING 6 Romex plastic sheathed Cable If romex cable was used to wire the electric box connect the green ground wire attached to the hanger ball and the green ground wire in the Romex cable using a 72B listed wire nut 6a Co
6. nduit Pipe If the wiring to the electrical box is enclosed in electrical conduit pipe connect the ground wire to the ground screw in the electrical box 7 Electrical Supply Connect the fan motor white wire to the supply white Neutral wire using a listed wire nut Connect the fan motor black wire and blue wire to the supply black hot wire using a listed wire nut Your fan is now wired to be turned on and off from the fan pull chain switch Figure 2 With wire nuts turned upward place green and white connections to one side of box and blue and black connections towards the other side and push carefully up into outlet box Supply Ground Black Supply White Supply Green or Bare Neutral Green Jumper Wire Black Fan White Fan Hot Neutral Figure 4 NOTE Check to see that all connections are tight including the ground and that no bare wire is visible at the wire nuts except for the ground wire 8 Raise canopy up to mounting bracket and fit screws into slots on canopy and rotate to the left to lock into place Tighten both screws Figure 5 NOTE Make sure that the electrical wires are completely inside the electrical box and not pinched between the ceiling canopy and the c I Twn TON D Mounting Bracket
7. ry mount fan at least 7 feet above the floor to an outlet box marked Acceptable for fan support Use screws provided with outlet box Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Your ceiling fan will fit any of the following electrical boxes 4 octagon box 3 octagon box 1 2 deep ceiling pan or a plaster ring with 3 1 2 mounting hole centers mounted on one of the above listed boxes Your new fan will also install on a wiremold No 5738 fixture box The electrical box must be securely anchored an capable of withstanding a load of at least 50 pounds If your ceiling fan does not have one of the above electrical boxes for proper wiring you may wish to contact a licensed electrician for installation RULES FOR SAFE INSTALLATION 1 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician 2 All wiring must satisfy National and Local electrical codes The ceiling fan must be grounded as a precaution against possible electrical shock 3 The electrical outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds 4 WARNING To reduce the risk of fire electrical shock and or personal injury a Be sure electricity is
Download Pdf Manuals
Related Search
Related Contents
OmegaT 2.6 - User`s Guide Sanus Systems ELM430 User's Manual L`installation électrique dans l`habitat : mode d`emploi Impex SB-670 User's Manual ezEdit Log Editor r-520lk r-520lw service manual MAJOR/MAXXOR Régulation D.P.TRONIC Samsung SOULb SGH-U800 Benutzerhandbuch Copyright © All rights reserved.
Failed to retrieve file