1. 8 TROUBLESHOOTING GUIDE 12 Voltage and Circuit Protection 8 REPAIR PARTS 13 OPERATING PROCEDURES 9 10 ESPANOL 15 Know Your Air Compressor 9 HOW TO ORDER REPAIR PARTS back cover SPECIFICATION CHART Model No 919 152350 Running Horsepower 1 Displacement CFM 4 8 Bore 1 7 8 Stroke 1 1 4 Voltage Single Phase 120 Minimum Branch Circuit Requirement 10 amps Fuse Type Time Delay SCFM Q 40 psig 3 7 SCFM Q 90 psig 2 6 FULL ONE YEAR WARRANTY AIR COMPRESSOR If this air compressor fails due to a defect in material or workmanship within one year from the date of purchase RETURN IT TO THE NEAREST SEARS REPAIR CENTER THROUGHOUT THE UNITED STATES AND SEARS WILL REPAIR IT FREE OF CHARGE If purchased from Orchard Supply Hardware return to the nearest Orchard Store and Orchard will repair it free of charge If this air compressor is used for commercial or rental purposes the warranty will apply for ninety days from the date of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates II 60179 08593 2 ENG SAFETY GUIDELINES DEFINITIONS SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the symbols below Please read the manual and
2. 24 PIEZAS DE REPARACI N 13 Conozca su compresor de aire 21 COMO SOLICITAR PIEZAS PARA REPARACI N contratapa HOJA DE ESPECIFICACIONES Modelo 919 152350 Potwncia de trabajo 0 1 CFM de desplazamiento 4 8 Di metro 1 7 8 Carrera 1 1 4 Voltaje Monof sico 120 Requerimientos m nimo por circuito ramal 10 Tipo de fusible Acci n retardada SCFM a 40 PSIG 3 7 SCFM a 90 PSIG 2 6 GARANT A COMPLETA POR UN ANO COMPRESOR DE AIRE Si este compresor de aire fallara por defectos en materiales o mano de obra dentro del lapso de un afio a partir de la fecha de su compra DEVU LVALO AL CENTRO DE REPARACIONES SEARS MAS CERCANO DENTRO DE LOS ESTADOS UNIDOS Y SEARS LO REPARAR LIBRE DE CARGO Si se hubiese comprado a Orchard Supply Hardware devu lvalo al comercio Orchard m s cercano y Orchard lo reparar libre de cargo Si este compresor de aire fuese utilizado para prop sitos comerciales o de alquiler la garant a solo tendr validez por noventa d as a partir de la compra Esta garant a le otorga derechos legales espec ficos aunque usted podr tener otros derechos que podr an variar entre estados Sears Roebuck and Co Dept 817WA Hoffman Estates ll 60179 08593 14 SP DEFINICIONES DE NORMAS DE SEGURIDAD SEGURIDAD Y PREVENCI N DE PROBLEMAS DEL EQUIPO Para ayudar al reconocimiento de esta informaci n hemos utilizado los s mbol
3. El juego de la barra de conexi n Juego de empaquetaduras y sellos Conjunto de sujeci n juego de anillo Manual del propietario R tulo advertencia Cable el ctrico Alambre de puente 08593 CONTENIDO HOJA DE ESPECIFICACIONES 14 Descripci n de operaciones 21 GARANT A 0 000 14 Como usar su unidad 22 NORMAS DE SEGURIDAD 15 18 Como detenerla 22 GLOSARIO l acid ada 19 C mo utilizar z calos y enchufes de ACCESORIOS 19 conexi n rapida 22 ENSAMBLADO 19 C mo utilizar el pico hembra para el inflado Contenido de la caja 19 de los neumaticos 22 C mo extra t el compres r de 39 C mo utilizar la pistola sopladora 22 INSTALACI N 20 Antes de comenzar 22 Ubicaci n delr compresor de aire sin iat 20 C mo dar arranque 22 z SERVICIOS Y REGULACIONES 23 Instrucciones para conectaratierra 20 ER Reemplazo de la manguera de aire 23 Extensiones el ctricas 20 Protecci n del voltaje y del circuito 20 ALMACENAJE UEM RUE I 23 PROCEDIMIENTOS OPERATIVOS _ 21 22 GUIA DE DIAGNOSTICO DE PROBLEMAS
4. TY LIKE ANY OTHER ELECTRICALLY POWERED DEVICE IF ITIS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELEC TROCUTION ELECTRICAL GROUNDING FAILURE TO PROVIDE ADE QUATE GROUNDING TO THIS PRODUCT COULD RESULT IN SERIOUS INJURY OR DEATH FROM ELEC TROCUTION SEE GROUNDING INSTRUCTIONS RISK TO BREATHING WHAT CAN HAPPEN THE COMPRESSED AIR DIRECTLY FROM YOUR COM PRESSOR IS NOT SAFE FOR BREATHING THE AIR STREAM MAY CONTAIN CARBON MONOXIDE TOXIC VAPORS OR SOLID PARTICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOL VENTS PAINT REMOVER INSECTICIDES WEED KILLERS CONTAIN HARMFUL VAPORS AND POISONS 5 ENG r HOW TO PREVENT IT NEVER OPERATE THE COMPRESSOR OUTDOORS WHEN IT IS RAINING OR IN WET CONDITIONS NEVER OPERATE COMPRESSOR WITH PROTECTIV COVERS REMOVED OR DAMAGED ANY ELECTRICAL WIRING OR REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHO RIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELECTRICAL GROUNDING CORRECT VOLT AGE AND ADEQUATE FUSE PROTECTION HOW TO PREVENT IT AIR OBTAINED DIRECTLY FROM THE COMPRESSOR SHOULD NEVER BE USED TO SUPPLY AIR FOR HUMAN CONSUMPTI
5. 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacion Au Canada pour service en francais a domicilio y para ordenar piezas 4 800 LE FOYER 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 www sears ca SEARS O Sears Roebuck and Co Registered Trademark Trademark V Service Mark of Sears Roebuck and Co Marca Registrada TM Marca de F brica SM Marca de Servicio de Sears Roebuck and Co Marque de commerce MD Marque d pos e de Sears Roebuck and
6. DIGOS LOCALES Y FEDERALES PREVIO AL CONSUMO HUMANO TRABAJE EN UN REA CON BUENA VENTILACI N CRUZADA LEA Y SIGA LAS INSTRUCCIONES DE SEGURIDAD PROVISTAS EN EL R TULO O EN LOS DATOS DE LAS HOJAS DE SEGURIDAD DEL MATERIAL QUE EST PULVERIZANDO USE EL RESPIRADOR APROBADO NIOSH MSHA DESIGNADO PARA UTILIZARSE CON SU APLICACI N ESPEC FICA A08593 PELIGRO RIESGO DE QUEMADURAS QU PUEDE OCURRIR TOCAR EL METAL EXPUESTO TAL COMO EL CABEZAL DEL COMPRESOR O LOS TUBOS DE SALIDA DEL ESCAPE PUEDE OCASIONARLE SERIAS QUEMADURAS RIESGO DE PARTES M VILES QU PUEDE OCURRIR PARTES MOVIBLES TALES COMO LA POLEA EL VOLANTE Y LA CORREA PODR AN SER LA CAUSA DE SERIAS LESIONES SI ELLAS ENTRARAN EN CONTACTO CON USTED O SUS ROPAS INTENTAR OPERAR EL COMPRESOR CON SUS PARTES DA ADAS O FALTANTES O LA REPARACI N DEL COMPRESOR CON SUS PROTECCIONES REMOVIDAS PUEDE EXPONERLO A USTED A PARTES MOVIBLES QUE PODR AN RESULTAR EN LESIONES SERIAS C MO PREVENIRLO JAM S TOQUE PARTES DE METAL EXPUESTAS EN EL COMPRESOR DURANTE O INMEDIATAMENTE DESPU S DE LA OPERACI N EL COMPRESOR PERMANECER CALIENTE POR VARIOS MINUTOS LUEGO DE LA OPERACI N NO LO CUBRA CON FUNDAS PROTECTORAS O INTENTE EL MANTENIMIENTO HASTA QUE LA UNIDAD HAYA ALCANZADO SU ENFRIAMIENTO Ok C MO PREVENIRLO NUNCA OPERE EL COMPRESOR SIN SUS DEFENSAS O SUS CUBIERTAS REMOVIDAS O DA ADAS CUALQUIER REPARACI N
7. FUNCIONAMIENTO PUEDE RESULTAR EN LESIONES PERSONALES O DANOS A LA PROPIEDAD 15 5 C MO PREVENIRLO OPERE SIEMPRE EL COMPRESOR EN UN SECTOR BIEN VENTILADO Y LIBRE DE MATERIALES COMBUSTIBLES GASOLINA O EMANACIONES DE SOLVENTE EN UN REA DE ROCIADO DE MATERIALES INFLAMABLES UBIQUE AL COMPRESOR POR LO MENOS A 6 1M 20 PIES DE DISTANCIA DEL REA DE ROCIADO PODR A REQUERIRSE UNA EXTENSI N DE LA MANGUERA ALMACENE LOS MATERIALES INFLAMABLES EN UNA UBICACI N SEGURA ALEJADOS DEL COMPRESOR JAM S COLOQUE OBJETOS APOYADOS O SOBRE EL COM PRESOR OPERE EL COMPRESOR EN UN SECTOR ABIERTO POR LO MENOS A 30 CM 12 PULGADAS ALEJADO DE CUALQUIER PARED U OBSTRUCCI N QUE RESTRINJA EL FLUJO DE AIRE FRESCO A LAS ABERTURAS DE VENTILACI N OPERE EL COMPRESOR EN UN SECTOR LIMPIO SECO Y BIEN VENTILADO NO OPERE LA UNIDAD EN ESPACIOS CERRADOS O CUALQUIER AREA CONFINADA MANT NGASE SIEMPRE ALERTA CADA VEZ QUE EL PRODUCTO ESTE FUNCIONANDO A08593 PELIGRO RIESGO DE EXPLOSI N TANQUE DE AIRE LAS SIGUIENTES CONDICIONES PUEDEN DETERMINAR EL DEBILITAMIENTO DEL TANQUE Y ORIGINAR UNA VIOLENTA EXPLOSI N DEL MISMO SIENDO CAUSA DE DA OS A LA PROPIEDAD O LESIONES SERIAS QU PUEDE OCURRIR 1 DRENAJE INADECUADO DEL AGUA CONDENSADA EN EL TANQUE SIENDO LA CAUSA DEL XIDO QUE REDUCE EL ESPESOR DEL TANQUE DE ACERO 2 MODIFICACIONES O INTENTO DE REPAR
8. Z A08548 Valve Plate Assembly SSG 8169 O Ring AC 0187 1 Outlet Tube Gasket Sub Pump Assembly gt Rod Assembly Pre Formed Compression Ring Connecting Rod Cap D21127 Screw 10 24 x SSF 3147 Screw 3 8 16 UNC Cylinder Sleeve AC 0815 Timing Belt D25731 Pump Isolator 5 CAC 1319 1 Shroud left D21709 Label Tool Rating CAC 1320 Shroud right CAC 1206 1 Clamp CAC 4324 Pressure Valve Assembly and Hose x SUDL 9 1 Screw Ground SSS 16 Switch x SSF 3156 Shroud Screws 5 CAC 1211 Housing Isolator 3 D21708 Label Performance NOT ILLUSTRATED NO SE MUSTRAN 30 45 in lbs x 4929 Fastener Kit gt KK 4964 Connecting Rod Kit D30139 Gasket amp Seal Kit D30324 Ring Kit A08593 Owner s Manual LA 3146 Label Warning D23786 Power Cord D23787 Jumper Wire 13 ENG DESCRIPCI N Tornillo 10 24 x 7 8 4 Cabezal del cilindro Sello del tubo Junta Cabezal Placa de la v lvula Anillo O Tubo de salida Junta Conjunto de Sub Bomba Ensamblaje de la biela Ring Anillo de compresi n preformado Tapa de la barra de conexi n Tornillo 10 24 Tornillo 3 8 16 UNC Manga del Cilindro Correa de regulaci n Aislante de pompe 5 Cubierta izquierda R tulo grado de la herramienta Lubierta derecha Abrazadera V lvula de presi n y manguera Tornillos para Tierra Interruptor Tornillos para la cubierta 5 Aislante del casco 3 R tulo funcionamiento El juego de sujetadores
9. en movimiento o fuentes de aire comprimido quedan Desenchufe el compresor antes de intentar cualquier reparaci n PROBLEMA P rdidas de aire El compresor no entrega suficiente aire El motor no trabaja Alta presi n de descarga No puede ser reducida 08593 CAUSA Conexi n suelta de la manguera Uso excesivamente prolongado del aire Orificio en la manguera Orificio en la manguera Estall el fusible se dispar el interruptor autom tico El cable de extensi n el ctrica tiene una longitud o calibre err neos Conexiones el ctricas sueltas Fallas del motor La v lvula de regulaci n de la presi n no funciona 24 SP expuestas al reparar el compresor Ello podr a ocasionar lesiones personales CORRECCI N Ajustar la conexi n Disminuir la cantidad de uso de aire Su compresor no tiene suficiente capacidad para los requerimientos de aire a los que est siendo sometido Reemplace la manguera Ajuste las conexiones 1 Verifique la caja de fusibles inspeccionando la existencia de fusibles fundidos y reemplace los necesarios Restablezca la posi ci n del interruptor autom tico del circuito No utilice un fusible o interruptor autom tico de mayor valor que el especificado para el ramal de su circuito 2 Verifique que el fusible sea el adecuado Debe utilizar fusibles de acci n retardada 3 Verifique el problema del sumin istro de bajo voltaje 4 Verifique
10. instructions for the air tool or the blow gun adapter has to be assembled to blow device gun A08593 10 ENG SERVICE AND ADJUSTMENTS Air Hose Replacement DO NOT replace the hose with standard hose that is The air hose attached to your compressor has an not equipped with the pressure adjusting integral pressure adjusting valve at the working end of valve appropriate assembly for the hose Should service or replacement be required S your compressor is available at Sears make sure that the pressure adjusting valve is present in the air hose line T Do not allow hose to become kinked or pinched at any time This is important to avoid damage to your compressor and to maintain pressure adjusting valve control ACA STORAGE 1 Setthe On Off switch to OFF and unplug the 3 Protect the electrical cord and air hose from dam cord age by winding them loosely around the air com 2 Relieve all pressure from the air compressor head pressor and air hose by turning the adjustable pressure 4 Store the air compressor in a clean and dry loca valve to 10 PSI tion 11 ENG 08593 TROUBLESHOOTING 1 AH PROBLEM Air Leaks Compressor is not delivering enough air Motor will not run High discharge pressure Cannot be adjusted lower 08593 CAUSE Hose fitting loose Prolonged excessive use of air Hole in hose Air leaks Fuse
11. la extensi n del conduc tor el ctrico 5 Desconecte los otros artefactos el ctricos que estuvieren operan do en el ramal del circuito que le corresponde al compresor Verifique la extensi n del conductor el ctrico Verifique la conexi n en la caja terminal Contacte a un t cnico calificado en servicio Riesgo de explosi n NO opere el compresor si este problema existiera Deber reem plazarse la v lvula de regulaci n de la presi n NOTES NOTAS 25 SP 08593 NOTES NOTAS A08593 26 SP NOTES NOTAS 27 SP A08593 me or ours Get it fixed at Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or night 1 800 469 4663 U S A and Canada www sears com www sears ca Our Home For repair of carry in products like vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears
12. ACIONES AL TANQUE 3 MODIFICACIONES NO AUTORIZADAS A LA V LVULA DE DESCARGA V LVULA DE SEGURIDAD O CUALQUIER OTRO COMPONENTE QUE CONTROLE LA PRESI N DEL TANQUE 4 1 VIBRACI N EXCESIVA PUEDE DEBILITAR EL TANQUE DE AIRE Y CAUSAR SU RUPTURA O EXPLOSI N AGREGADOS Y ACCESORIOS EL EXCESO A LOS VALORES DE PRESI N ESTABLECIDOS PARA LAS HERRAMIENTAS NEUM TICAS PISTOLAS ROCIADO RAS ACCESORIOS ACTIVADOS POR AIRE CUBIERTAS Y OTROS OBJETOS INFLABLES PUEDE CAUSAR SU EXPLOSI N O SER ARROJADOS PUDIENDO OCASIONAR SERIAS LESIONES RIESGO DE OBJETOS ARROJADOS POR EL AIRE QU PUEDE OCURRIR EL CHORRO DE AIRE COMPRIMIDO PUEDE CAUSAR DA OS SOBRE LOS TEJIDOS BLANDOS DE LA PIEL EXPUESTA Y PUEDE PROPULSAR SUCIEDAD ASTILLAS PART CULAS SUELTAS Y PEQUE OS OBJETOS A ALTA VELOCIDAD OCASIONANDO DA OS A LA PROPIEDAD O LESIONES PERSONALES 08593 C MO PREVENIRLO DRENE EL TANQUE DIARIAMENTE O DESPU S CADA USO SI EL TANQUE GENERA UNA P RDIDA REEMPL CELO INMEDIATAMENTE CON UN NUEVO TANQUE O REEMPLACE EL COMPRESOR COMPLETO JAM S PERFORE SUELDE O EFECT E MODIFICACI N ALGUNA AL TANQUE O SUS ACCESORIOS EL TANQUE EST DISE ADO PARA RESISTIR PRESIONES OPERATIVAS ESPEC FICAS JAM S EFECT E AJUSTES O SUSTITUYA PARTES QUE ALTEREN LAS REGULACIONES DE PRESI N ORIGINALES DE F BRICA PARA UN CONTROL ESENCIAL DE LA PRESI N DEBE USTED INSTALAR UN REGULADOR Y UN MEDIDOR DE PRESI N A LA SALIDA DE
13. Cinta selladora para filetes de rosca Usada para aplicar sobre los filetes a fin de eliminar las perdidas de aire Pico hembra para el inflado de los neum ticos Adaptador para el inflado de neum ticos Pistola sopladora Ideal para soplar limpiar e inflar Tobera de seguridad Previene el incremento de la presi n Adaptador para pistola sopladora Conectado a la pistola sopladora o al extremo hembra de la manguera permite el uso del pico c nico del inflador o de la aguja para inflado Aguja para inflado Utilizada para el inflado de pelotas deportivas Inflador c nico Utilizado para el inflado de juguetes inflables o colchones de aire 08593 C mo utilizar su unidad C mo detenerla 1 Coloque la posici n de la llave interruptora On Off en la posi ci n OFF C mo utilizar z calos y conectores de conexi n r pida 1 Aplique cinta selladora sobre los filamentos de los z calos y conectores r pidos 2 Ensamble el conector r pido a la manguera Enchufe el conector a la pistola sopladora y al pico hembra para el inflado de los neum ticos Aj stelo firmemente Ello facilitar el cambio de dichos accesorios 3 Tire hacia atr s la cupla de conexi n del acoplamiento r pido e inserte el enchufe Ver la figura de arriba 4 Deslice la cupla de acoplamiento a su posici n inicial C mo utilizar el pico hembra para el inflado de los neum ticos 1 Conecte a la manguer
14. FEET AWAY FROM SPRAY AREA AN ADDITIONAL LENGTH OF HOSE MAY BE REQUIRED STORE FLAMMABLE MATERIALS IN A SECURE LOCA TION AWAY FROM COMPRESSOR NEVER PLACE OBJECTS AGAINST OR ON TOP OF COMPRESSOR OPERATE COMPRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTI LATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA ALWAYS REMAIN IN ATTENDANCE WITH THE PROD UCT WHEN IT IS OPERATING 08593 HAZARD RISK OF BURSTING AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY WHAT CAN HAPPEN 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATIONS TO THE UNLOADER VALVE SAFETY VALVE OR ANY OTHER COMPONENTS WHICH CONTROL TANK PRESSURE 4 EXCESSIVE VIBRATION CAN WEAKEN THE AIR TANK AND CAUSE RUPTURE OR EXPLOSION ATTACHMENTS amp ACCESSORIES EXCEEDING THE PRESSURE RATING OF AIR TOOLS SPRAY GUNS AIR OPERATED ACCESSORIES TIRES AND OTHER INFLATABLES CAN CAUSE THEM TO EXPLODE OR FLY APART AND COULD RESULT IN SERIOUS INJURY RISK FROM FLYING OBJECTS WHAT CAN HAPPEN THE C
15. L AIRE DE SU COMPRESOR Sl NO ESTUNIER EQUIPADO SIGA LAS RECOMENDACIONES DE LOS FABRICANTES DE SU EQUIPO Y JAM S EXCEDA LOS VALORES M XIMOS DE PRESI N PERMITIDOS PARA LOS ACCESORIOS JAM S USE EL COMPRESOR PARA INFLAR OBJETOS QUE REQUIEREN O BAJA PRESI N TALES COMO JUGUETES PARA LOS NI OS PELOTAS DE F TBOL PELOTAS DE BASQUET ETC C MO PREVENIRLO AL UTILIZAR EL COMPRESOR USE SIEMPRE ANTEOJOS DE SEGURIDAD ANSI Z87 1 APROBADOS CON PROTECCI N LATERAL JAM S APUNTE NINGUNA BOQUILLA O PULVERIZADOR HACIA PARTES DEL CUERPO A OTRAS PERSONAS O ANIMALES APAGUE SIEMPRE EL COMPRESOR Y PURGUE LA PRESI N DE LA MANGUERA DEL AIRE Y DEL TANQUE ANTES DE INTENTAR EL MANTENIMIENTO EL ACOPLE DE HERRAMIENTAS O ACCESORIOS 16 SP PELIGRO RIESGO DE DESCARGA EL CTRICA QU PUEDE OCURRIR SU COMPRESOR DE AIRE EST ACCIONADO POR ELECTRICIDAD COMO CUALQUIER OTRO DISPOSITIVO EL CTRICO IMPULSADO EL CTRICAMENTE SI NO SE LO UTILIZA ADECUADAMENTE PODR A CAUSARLE UNA DESCARGA EL CTRICA LAS REPARACIONES INTENTADAS POR PERSONAL NO CALIFICADO PODRIAN OCASIONAR SERIAS LESIONES O LA MUERTE POR ELECTROCUCI N CONEXI N A TIERRA DEJAR DE PROVEER UNA ADECUADA CONEXI N A TIERRA A ESTE PRODUCTO PODR A OCASIONAR LESIONES SERIAS O LA MUERTE POR ELECTROCUCI N VER INSTRUCCIONES PARA LA PUESTA A TIERRA RIESGO DE INHALACI N QU PUEDE OCURRIR EL AIRE COMPRIMIDO PROVENIENTE DEL COMPRESOR NO ES SANO
16. OMPRESSED AIR STREAM CAN CAUSE SOFT TIS SUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT CHIPS LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY 08593 HOW PREVENT IT DRAIN TANK DAILY OR AFTER EACH USE IF TANK DEVELOPS A LEAK REPLACE IT IMMEDIATELY WITH A NEW TANK OR REPLACE THE ENTIRE COMPRESSOR NEVER DRILL INTO WELD OR MAKE ANY MODIFICA TIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPER ATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTITUTIONS TO ALTER THE FACTORY SET OPERATING PRESSURES FOR ESSENTIAL CONTROL OF AIR PRESSURE YOU MUST INSTALL A PRESSURE REGULATOR AND PRES SURE GAUGE TO THE AIR OUTLET OF YOUR COM PRESSOR FOLLOW THE EQUIPMENT MANUFACTURERS RECOMMENDATION AND NEVER EXCEED THE MAXIMUM ALLOWABLE PRESSURE RATING OF ATTACHMENTS NEVER USE COMPRESSOR TO INFLATE SMALL LOW PRESSURE OBJECTS SUCH AS CHILDREN S TOYS FOOTBALLS BASKETBALLS ETC HOW TO PREVENT IT ALWAYS WEAR ANSI Z87 1 APPROVED SAFETY GLASS ES WITH SIDE SHIELDS WHEN USING THE COMPRES SOR NEVER POINT ANY NOZZLE OR SPRAYER TOWARD ANY PART OF THE BODY OR AT OTHER PEOPLE OR ANIMALS ALWAYS TURN THE COMPRESSOR OFF AND BLEED PRESSURE FROM THE AIR HOSE AND TANK BEFORE ATTEMPTING MAINTENANCE ATTACHING TOOLS OR ACCESSORIES 4 ENG HAZARD RISK OF ELECTRICAL SHOCK WHAT CAN HAPPEN YOUR AIR COMPRESSOR IS POWERED BY ELECTRICI
17. ON IN ORDER TO USE AIR PRODUCED BY THIS COMPRESSOR FOR BREATHING SUITABLE FIL TERS AND IN LINE SAFETY EQUIPMENT MUST BE PROPERLY INSTALLED IN LINE FILTERS AND SAFETY EQUIPMENT USED IN CONJUNCTION WITH THE COM PRESSOR MUST BE CAPABLE OF TREATING AIR TO ALL APPLICABLE LOCAL AND FEDERAL CODES PRIOR TO HUMAN CONSUMPTION WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PRO VIDED ON THE LABEL OR SAFETY DATA SHEETS FOR THE MATERIAL YOU ARE SPRAYING USE A NIOSH MSHA APPROVED RESPIRATOR DESIGNED FOR USE WITH YOUR SPECIFIC APPLICATION A08593 HAZARD RISK OF BURNS WHAT CAN HAPPEN TOUCHING EXPOSED METAL SUCH AS THE COMPRES SOR HEAD OR OUTLET TUBES CAN RESULT IN SERIOUS BURNS RISK FROM MOVING PARTS WHAT CAN HAPPEN MOVING PARTS SUCH AS THE PULLEY FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING ATTEMPTING TO OPERATE COMPRESSOR WITH DAM AGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY RISK OF FALLING WHAT CAN HAPPEN A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COMPRESSOR AND COULD RESULT IN SERIOUS INJURY OR DEATH TO THE OPERATOR RISK OF PROPERTY DAMAQE WHEN TRANSPORTING COMPRESSOR Fire Inhalation Damage to Vehicle Surfaces HOW TO PREVENT IT NEVER TO
18. Owners Manual CRRFTSMRN Permanently Lubricated Compact AIR COMPRESSOR Model No 919 152350 e Safety Guidelines Assembly Operation Maintenance CAUTION Read the Safety Guidelines Service and Adjustments and All Instructions Carefully Before Troubleshooting Operating Repair Parts Espa ol Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman A08593 Rev 0 11 4 04 TABLE OF CONTENTS SPECIFICATION CHART 2 Description of Operation 9 WARRANTY 2 How to Use Your Unit 10 SAFETY GUIDELINES 3 6 Mil oi roule c M et e 10 GLOSSARY 7 To Use Quick Connect Sockets and Plugs 10 ACCESSORIES 7 To Use Female Tire Chuck 10 ASSEMBLY 7 To Use Blow Gun 10 Contents of Carton 7 Before Starting 10 To Remove Air compressor From Carton 7 How to Start uctor A ERE 10 INSTALLATION 8 SERVICE AND ADJUSTMENTS 11 Location of Air Compressor 8 Air Hose Replacement 11 Grounding Instructions 8 STORAGE iyuq 11 Extension Cords
19. PARA RESPIRAR EL CHORRO DE AIRE PUEDE CONTENER MON XIDO DE CARBONO VAPORES T XICOS O PART CULAS S LIDAS PROVENIENTES DEL TANQUE LA INHALACI N DE DICHOS CONTAMINANTES PUEDE LLEGAR A CAUSAR SERIAS LESIONES O LA MUERTE EL ROCIADO DE MATERIALES TALES COMO PINTURA SOLVENTES REMOVEDORES DE PINTURA INSECTICIDAS MATA HIERBAS CONTIENEN EMANACIONES DANINAS Y VENENOSAS 17 SP 24 C MO PREVENIRLO JAM S OPERE EL COMPRESOR A LA INTEMPERIE CUANDO EST LLOVIENDO O EN CONDICIONES DE HUMEDAD NUNCA OPERE EL COMPRESOR SIN SUS DEFENSAS O SUS CUBIERTAS REMOVIDAS O DANADAS CUALQUIER CONEXI N EL CTRICA O REPARACI N REQUERIDA POR ESTE PRODUCTO DEBE SER EFECTUADA POR PERSONAL AUTORIZADO DE LOS SERVICENTROS DE ACUERDO A LOS C DIGOS EL CTRICOS NACIONALES Y LOCALES ASEG RESE QUE EL CIRCUITO EL CTRICO AL CUAL EST CONECTADO EL COMPRESOR SUMINISTRA APROPIADA CONEXI N A TIERRA TENSI N CORRECTA Y UNA ADECUADA PROTECCI N DE FUSIBLES C MO PREVENIRLO EL AIRE OBTENIDO DIRECTAMENTE DEL COMPRESOR JAM S DEBER SER UTILIZADO PARA PROVEER AIRE PARA CONSUMO HUMANO PARA PODER UTILIZAR EL AIRE PRODUCIDO POR ESTE COMPRESOR Y HACERLO RESPIRABLE DEBER N INSTALARSE UN FILTRO ADECUADO Y UN EQUIPO DE SEGURIDAD INTERCALADO LOS FILTROS INTERCALADOS TANTO COMO EL EQUIPO DE SEGURIDAD UTILIZADO EN CONJUNTO CON EL COMPRESOR DEBER N SER CAPACES DE PROCESAR EL TRATAMIENTO DEL AIRE DE ACUERDO A TODOS LOS C
20. REQUERIDA POR ESTE PRODUCTO DEBE SER EFECTUADA POR PERSONAL AUTORIZADO DE LOS SERVICENTROS RIESGO DE CAIDA K QU PUEDE OCURRIR UN COMPRESOR PORT TIL PUEDE CAERSE DE LA MESA EL BANCO DE TRABAJO O DEL TECHO DA ANDO AL COMPRESOR Y PUDIENDO RESULTAR EN SERIAS LESIONES O LA MUERTE DEL OPERADOR RIESGO DE DA OS A LA PROPIEDAD AL TRANSPORTAR EL COMPRESOR Fuego inhalaci n da o a la superficie de veh culos C MO PREVENIRLO OPERE SIEMPRE EL COMPRESOR EN UNA POSICI N ESTABLE Y SEGURA A FIN DE PREVENIR EL MOVIMIENTO ACCIDENTAL DE LA UNIDAD JAM S OPERE EL COMPRESOR SOBRE UN TECHO U OTRA POSICI N ELEVADA UTILICE MANGUERAS ADICIONALES DE AIRE PARA ALCANZAR POSICIONES ALTAS Para unidades que requieran aceite en la bomba o motores a gasolina QU PUEDE OCURRIR 08593 C MO PREVENIRLO DEPOSITE EL COMPRESOR SOBRE UNA ALFOMBRILLA PRO TECTORA CUANDO LO TRANSPORTE A FIN DE PROTEGER AL VEH CULO DE P RDIDAS POR GOTEO RETIRE EL COMPRESOR DEL VEH CULO INMEDIATAMENTE DESPU S DE SU ARRIBO AL DESTINO 18 SP GLOSARIO Familiar cese con los siguientes t rminos antes de operar la C digo de certificaci n Los productos que usan una o unidad m s de las siguientes marcas UL CUL ETL CETL han sido evaluados por OSHA laboratorios independientes cer Cm Cubic feet per minute Pies cubicos por minute tificados en seguridad y re nen los est ndares suscriptos SCFM St
21. UCH ANY EXPOSED METAL PARTS ON COMPRESSOR DURING OR IMMEDIATELY AFTER OPER ATION COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL Or HOW TO PREVENT IT NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAMAGED OR REMOVED ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL M HOW TO PREVENT IT ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE POSITION TO PREVENT ACCIDENTAL MOVE MENT OF THE UNIT NEVER OPERATE COMPRESSOR ON A ROOF OR OTHER ELEVATED POSITION USE ADDITIONAL AIR HOSE TO REACH HIGH LOCATIONS For units requiring oil in pump or gasoline engines WHAT CAN HAPPEN OIL CAN LEAK OR SPILL AND COULD RESULT IN FIRE OR BREATHING HAZARD SERIOUS INJURY OR DEATH CAN RESULT OIL LEAKS WILL DAMAGE CARPET PAINT OR OTHER SURFACES IN VEHICLES OR TRAILERS HOW TO PREVENT IT ALWAYS PLACE COMPRESSOR ON A PROTECTIVE MAT WHEN TRANSPORTING TO PROTECT AGAINST DAMAGE TO VEHICLE FROM LEAKS REMOVE COMPRESSOR FROM VEHICLE IMMEDIATELY UPON ARRIVAL AT YOUR DESTINATION GLOSSARY Become familiar with these terms before operating the Code Certification Products that bear one or more unit of the following marks UL CUL ETL CETL have been evaluated by OSHA certified independent safety laboratories and meet the applicable Un
22. a el pico hembra para inflado de neum ticos 2 Vea el p rrafo como poner en marcha el compresor de aire 3 Coloque el pico hembra de inflado de cubiertas sobre el tallo de la v lvula de la cubierta que debe ser inflada 4 ncremente lentamente el nivel de presi n de la v lvula reguladora hasta el valor PSI recomendado por el fabri cante de la cubierta Nota Para asegurar el valor correcto de la presi n de inflado utilice el calibrador de presi n C mo utilizar la pistola sopladora 1 Conecte la pistola sopladora a la manguera A PR A a Si no se intenta utilizar accesorio alguno con la pistola sopladora DEBE ensamblarse la boquilla de seguridad 2 Ensamble la boquilla de seguridad o el adaptador del extremo de la manguera a la pistola sopladora Vea la pr xima figura NOTA Para poder utilizar la aguja de inflar o el inflador c nico el adaptador del soplador debe estar ensamblado a la pistola sopladora A08593 Boquilla de seguridad Adaptador del soplador Palanca de manguera Aguja para inflar Inflador c nico Boquilla de seguridad Conecte la aguja para inflar o el inflador c nico al adaptador de la pistola sopladora Vea el p rrafo como poner en marcha para dar arranque al compresor de aire Presione la palanca de la pistola sopladora a fin de permitir el paso del aire Antes de comenzar Ts Coloque el interruptor On Off en la posici n OFF Llev
23. ardard cubic feet per minute Pies c bicos est ndar por los laboratorios dedicados a la certificaci n de la por minuto una unidad de medida que permite medir la canti seguridad dad de entrega de aire Ramal Circuito el ctrico que transporta electricidad desde PSIG Pound per square inch Libras por pulgada cuadrada el panel de control hasta el tomacorriente ACCESORIOS Esta unidad es suficiente para abastecer de energ a el ctrica a los siguientes accesorios Estos se encuentran disponibles a trav s del cat logo para herramientas el ctricas y manuales en cualquiera de los comercios que mantiene la l nea completa de SEARS Accesorios Herramientas para carpinter a Juegos de conexi n r pida varias medidas M quina clavadora abrochadora Herramientas por especialidades Cepillo neum tico Pistola infladora sopladora Pistola engrasadora Pistola para aplicaci n de sellador ENSAMBLADO Contenido de la caja de embalaje 1 Compresor de aire con manguera y v lvula reguladora de presi n cant 1 Recept culo para conexi n r pida Cant 1 Enchufe para conexi n r pida Cant 2 Cinta selladora para rosca Cant 1 Pico hembra para llenado de aire a los neum ticos Cant 1 Pistola sopladora Cant 1 Boquilla de seguridad Cant 1 Adaptador para pistola sopladora Cant 1 Aguja para inflado Cant 1 m WD 0 Inflador roscado Cant 1 Para extraer el compresor de aire de su
24. blown circuit breaker tripped Extension cord is wrong length or gauge Loose electrical connections Faulty motor Adjustable pressure valve not functioning 12 ENG Voltage sources moving parts or compressed air sources are exposed when repairing the compressor Personal injury can occur Unplug the compressor before attempting any repairs CORRECTION Tighten fitting Decrease the amount of air usage Your compressor is not large enough for the air requirement Replace the hose Tighten fittings 1 Check fuse box for blown fuse and replace as necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit 2 Check for proper fuse You should be using a Time Delay fuse 3 Check for low voltage prob lem Check the extension cord 5 Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord Check wiring connection inside terminal box area Contact a Trained Service Technician Risk of burst ing DO NOT operate the compressor if this problem exists Adjustable pres sure valve must be replaced 1 AR ER lt OOODOODODODOANDAARWN REPAIR PARTS DIAGRAM 20 Torque 30 ft Ibs PARTNO DESCRIPTION x SSF 995 Screw 10 24 x 7 8 4 CAC 1196 Cylinder Head CAC 1212 Tube Seal CAC 1199 Head Gasket
25. cable de alimentaci n OPERATION Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci n de los distintos controles y regulaciones Conserve este manual para referencias futuras Interruptor ON OFF Z calo para conexi n r pida Descripci n de operaciones V lvula reguladora de presi n La v lvula de presi n controla la cantidad de presi n que circula desde el compresor de aire al accesorio La v lvula reguladora de presi n permite regular la presi n en un rango entre 10 y 125 PSI 125 PSI es el valor de presi n m s elevado que puede entregar este compresor Interruptor de prendido y apagado On Off localizado en el lado opuesto del compresor de aire Usado para prender y apagar el compresor de aire Z calo para conexi n r pida Facilita el recambio r pido de las herramientas Picos de conexi n r pida Instalados sobre las herramientas e insertado en los z calos de conexi n r pida facilita la rapidez del recambio de las herramientas 21 SP Inflador c nico oo d V lvula reguladora de presi n Pico hembra para el inflado de los t neum ticos Cinta selladora de filetes de rosca Picos de conexi n r pida Tobera de seguridad Adaptador para pistola sopladora Aguja para inflar
26. caja 1 Suj telo de la manija y lev ntelo fuera de su caja 2 Extraiga y descarte todo el embalaje del compre sor de aire 19 SP 08593 INSTALACION C MO PREPARAR LA UNIDAD Ubicaci n del compresor de aire Ubique al compresor de aire en una zona limpia seca y bien ventilada La bomba del compresor de aire y su carcasa han sido dise adas para permitir un enfriamiento adecuado Las aberturas de ventilaci n del compresor resultan entonces necesarias para el mantenimiento de una adecuada temperatura de funcionamiento No coloque g neros o contenedores enci ma ni en las proximidades de dichas aberturas INSTRUCCIONES PARA CONECTAR A TIERRA RIESGO DE DESCARGA ELECTRICA Ante la eventualidad de un cortocir cuito la conexi n a tierra reduce el riesgo de elec trocuci n proveyendo un conductor de escape para la corriente el ctrica Este compresor de aire debe estar adecuadamente conectado a tierra h AD H El compresor port til de aire est equipado con un cable que tiene un conductor destinado a tierra con una espiga apropiada para su conexi n ver las sigu ientes ilustraciones El enchufe debe ser utilizado con un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los c digos y ordenanzas locales 1 Elcable que acompa a a esta unidad tiene una espiga para conexi n a tierra Esta DEBE ser utilizada con un tomacorriente conectado a tierra IMPORTANTE El tomacorr
27. compressor are necessary to maintain proper operating temperature Do not place rags or other containers on or near these openings GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded T AR The portable air compressor is equipped with a cord having a grounding wire with an appropriate ground ing plug see following illustrations The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordi nances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the grounded plug DO NOT USE AN ADAPTER See figure po 10 Grounded Outlets Grounding Pin 3 Inspect the plug and cord before each use Do not use if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the com pressor is properly grounded have the installation checked by a qualified electrician A08593 IMPROPER GROUNDING CAN RESULT IN ELEC T AR TRICAL SHOCK Do not modify the plug pro
28. d to blow gun or female hose end to allow the tapered Inflator or inflating nee dle to be used Inflating needle Used to inflate sport balls Tapered Inflator Used to inflate toy inflatables air mattresses 08593 How to Use Your Unit How to Stop 1 To Use Quick Connect Coupling and Studs 1 Set the On Off switch to OFF Apply thread sealant tape Blow Gun Adapter Inflating Needle Tapered Inflator Safety Nozzle Attach the inflating needle or tapered inflator to the blow gun adapter on the blow gun to threads of quick con 4 See the How to Start paragraph to start air nect coupling and studs compressor 2 Assemble the quick con 5 Depress lever on blow gun to release the air nect coupling to the hose Attach the studs to the blow gun and female tire chuck Tighten securely Before Starting This will make it easier to change over these 1 Place On Off switch to OFF accessories 2 Place the adjustable pres sure valve to 10 PSI 2 Attach hose and accessories AWARNING Too much air pressure causes a hazardous risk of 3 Pull quick connect coupling back and insert stud bursting Check the manufacturer s maximum See figure above pressure rating for air tools and accessories 2 Carefully follow the How to Start instruc 4 Slide coupling forward to lock in place tions To Use Female Tire Chuck 1 Attach female tire chuck to hose H
29. derwriters SCFM Standard cubic feet per minute a unit of Laboratories Standards for Safety measure of air delivery CFM Cubic feet per minute 7 Branch Circuit Circuit carrying electricity from elec PSIG Pounds per square inch gauge a unit of meas trical panel to outlet ure of pressure ACCESSORIES This unit is capable of powering the following Accessories The accessories are available through the current Power and Hand Tool Catalog or full line Sears stores Accessories Carpentry Tools Quick Connect Sets various sizes Finishing Nailer Stapler Specialty Tools Air Brush Inflating Blow Gun Grease Gun Caulk Gun ASSEMBLY Contents of Carton 1 Air Compressor with hose and pressure adjustment valve qty 1 Quick Connect Coupling qty 1 Quick Connect Studs qty 2 Thread Sealant Tape qty 1 Female Tire Chuck qty 1 Blow Gun qty 1 Safety Nozzle qty 1 Blow Gun Adapter qty 1 Inflating Needle qty 1 o0 Ur R OCT 0 Tapered Inflator qty 1 To Remove Air Compressor From Carton 1 Grasp handle and lift the air compressor out of the carton 2 Remove all packaging from air compressor and discard 7 ENG A08593 INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean dry and well ventilated area The air compressor pump and shroud are designed to allow for proper cooling The ventila tion openings on the
30. e el control de la presi n de la v lvula reguladora a la posici n 10 PSI Conecte mangueras y accesorios Demasiada presi n de aire ADVERTENCIA crea el riesgo de explosi n Verifique los valores m ximos recomendados por el fabricante para las herramientas de aire y accesorios Siga cuidadosamente las instrucciones dadas en C mo Poner en Marcha C mo poner en marcha 1 2 22 SP Coloque el interruptor On Off en la posici n OFF Enchufe el cable de energ a el ctrica en un tomacorriente conectado a tierra Coloque el interruptor On Off en la posici n ON para dar arranque al compresor Verifique los valores m ximos de presi n admitidos por el fabricante para la herramienta neum tica accesorio o cubierta neum tica del veh culo para la que ser usada La salida de presi n del compresor de aire jam s debe exceder los valores de presi n estipulados Incremente lentamente los valores de presi n desde el regulador de la v lvula de presi n Deber usted escuchar y percibir la presi n del aire que va siendo elevada por acci n de la v lvula reguladora Si dicha presi n no fuese liberada apague inmediatamente el compresor de aire La v lvula reguladora de la presi n deber ser reemplazada El aire comprimido proveniente APRECAUCION de la salida podra contener condensaci n de agua No roc e aire sin filtrar sobre un articulo que pudiese ser da ado Algunas herramientas o dispo
31. iente que ser utilizado deber haber sido conectado a tierra conforme a todos los c digos locales y ordenanzas 2 Aseg rese de que el tomacorriente que ser utilizado tenga la misma configuraci n que el enchufe de conexi n a tierra NO UTILICE UN ADAPTADOR Ver figura Enchufe 1 0 Tomacorrientes conectados a 11 tierra Z Espiga de conexi n a tierra 3 Inspeccione el enchufe y su cord n antes de cada uso No use si existieran signos de da os 4 Silasinstrucciones de conexi n a tierra no fueran comple tamente comprendidas o si se estuviera ante la duda acer ca de que el compresor estuviese adecuadamente conec tado a tierra haga verificar la instalaci n por un elec tricista competente 08593 20 SP ADVER LA CONEXI N INADECUADA A TIERRA PUEDE DETERMINAR UNA DESCARGA EL CTRICA No modifique el enchufe provisto Si el mismo no penetrara el tomacorriente disponible un electricista competente deber instalar uno apropiado La reparaci n del cable o del enchufe DEBER ser efectuada por un electricista competente Cables de extensi n el ctrica Use extensiones de manguera de aire antes que prolonga ciones de cables el ctricos a fin de prevenir ca das de ten si n perdida de la potencia el ctrica al motor y tambi n su recalentamiento Si no obstante debe utilizarse una extensi n de cable aseg rese de que e La extension el ctrica de 3 conductores te
32. nga un enchufe de conexi n a tierra de 3 hojas y que exista un recept culo que acepte el enchufe del producto Est en buenas condiciones No m s largo que 15 2 m 50 pies e Calibre 14 AWG o mayor La medida de los cables se incrementa a medida que su n mero ordinal decrece 12 10 y 8 AWG pueden ser usados tambi n NO USE 16 NI 18 AWG Protecci n del voltaje y del circuito Acerca del voltaje y la m nima cantidad de circuitos requeridos refi rase al Manual de piezas Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las sigu ientes condiciones 1 Que el voltaje suministrado a trav s de los ramales del circuito sea de 15 A D Que el circuito no sea utilizado para alimentar ninguna otra necesidad el ctrica iluminaci n artefactos etc 3 Que los cables de extensi n cumplan con las especificaciones 4 Que el circuito est equipado con un interruptor autom tico de 15 A o un fusible de acci n retar dada de 15 A NOTA Si el compresor estuviese conectado a un circuito protegido con fusibles utilice solamente los de acci n retardada identifi cados como D Si cualquiera de las condiciones enumeradas no pud iese ser cumplida o si el funcionamiento del compre sor causara reiteradas interrupciones de la energ a con la que se lo alimenta podr a ser necesario operar al mismo desde un circuito de 20 A Para ello no ser necesario cambiar su
33. os mostrados abajo S rvase leer el manual y prestar atenci n a dichas secciones fed Indica una situaci n de inminente riesgo la cual Si no es evitada causar la muerte o lesiones APRECAUCI N Indica una situaci n potencialmente peligrosa la cual si no es evitada podr a resultar en lesiones menores o moderadas Indica una situaci n potencialmente riesgosa que si no es evitada podr a resultar en la muerte o lesiones serias APRECAUCI N Usado sin el s mbolo de seguridad de alerta indica una situaci n potencial mente riesgosa la que si no es evitada podr a causar da os en la propiedad INSTRUCCIONES IMPORTANTES DE SEGURIDAD e GUARDE ESTAS INSTRUCCIONES La operaci n o el mantenimiento inadecuados de este producto podr an ocasionar serias lesiones y da os a la propiedad Lea y comprenda todas las advertencias e instrucciones de funcionamiento antes de utilizar este equipo RIESGO DE EXPLOSI N O INCENDIO QU PUEDE OCURRIR PARA LOS CONTACTOS EL CTRICOS ES NORMAL LA EXISTENCIA DE CHISPAS ENTRE EL MOTOR Y EL INTERRUPTOR A PRESI N SI LAS CHISPAS EL CTRICAS PROVENIENTES DEL COMPRESOR TOMARAN CONTACTO CON EMANACIONES DE MATERIALES INFLAMABLES ELLOS PODR AN ARDER ORIGINANDO INCENDIO O EXPLOSI N RESTRINGIR CUALQUIERA DE LAS ABERTURAS DE VENTILACI N CAUSARA UN SERIO RECALENTAMIENTO Y PODRIA PRODUCIR UN INCENDIO DEJAR DESATENDIDO ESTE PRODUCTO MIENTRAS EL MISMO ESTA EN
34. ow to Start 2 Seethe How to Start paragraph to start air 1 Place On Off switch to OFF compressor 2 Plug the power cord into the grounded outlet 3 Place the female tire chuck onto the tire valve 3 Place On Off switch to ON to start compressor stem of the tire to be inflated 4 Slowiy i h fth 4 Check the manufacturer s maximum pressure rat Pl y EBEN tne Sto dg ort i ing for the air tool accessory or vehicle tire being justa RS ES i to 5 ure manutactur used The air compressor outlet pressure must ero ote never exceed the maximum pressure rating tire pressure use a tire pressure gauge 5 Slowly increase the pressure setting of the To Use Blow Gun adjustable pressure valve You should be able to 1 Attach the blow gun to hose hear and feel air pressure being relieved by the adjustable pressure valve If pressure is not being A If relieved turn the air off immediately is not being The pressure valve must be replaced used with the blow gun the Compressed air from the safety noze MUST b Safety Nozzle 44 CAUTION outfit may contain water assembled 7 condensation Do not spray unfiltered air at 2 Assemble the safety nozzle or blow gun adapter an item that could be damaged Some air to blow gun See next figure operated tools or devices may require filtered NOTE To use the inflating needle or tapered inflator air Read the
35. pay attention to these sections Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous sit uation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury T 4 Used without the safety alert sym CAUTION bol indicates a potentially haz ardous situation which if not avoided may result in property damage E SAVE THESE INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUC TIONS BEFORE USING THIS EQUIPMENT RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS THEY MAY IGNITE CAUSING FIRE OR EXPLOSION RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE FIRE UNATTENDED OPERATION OF THIS PRODUCT COULD RESULT IN PERSONAL INJURY OR PROPERTY DAM AGE 3 ENG HOW TO PREVENT IT ALWAYS OPERATE THE COMPRESSOR IN A WELL VEN TILATED AREA FREE OF COMBUSTIBLE MATERIALS GASOLINE OR SOLVENT VAPORS IF SPRAYING FLAMMABLE MATERIALS LOCATE COM PRESSOR AT LEAST 20
36. ry to operate it from a 20 amp circuit It is not necessary to change the cord set 8 ENG OPERATION Know Your Air Compressor READ THIS OWNER S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT Compare the illustra tions with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference On Off Switch Quick Connect Coupling Description of Operation Pressure Adjustable Valve The pressure valve con trols the amount of pressure going from the air com pressor to the accessory The pressure adjusting valve can be used to set approximate pressure between 10 and 125 PSI 125 PSI is the highest pressure this compressor will deliver On Off Switch located on opposite side of air compressor Used to turn air compressor on and off Quick Connect Coupling Makes tool change overs easy Quick Connect Studs Install on tools and insert into the quick connect coupling to make tool change overs easier 9 ENG Tapered Inflator Pressure Adjustment Valve Female Tire Chuck Thread Sealant Tape Quick Connect Studs Safety Nozzle Blow Gun Adapter Inflating Needle Thread Sealant Tape Use on threads to eliminate air leaks Female Tire Chuck Adapter for inflating tires Blow Gun Ideal for blowing cleaning and inflating Safety Nozzle Prevents pressure build up Blow Gun Adapter Attache
37. sitivos accionados por aire requieren aire filtrado Lea las instrucciones dadas para las herramientas neum ticas o los accesorios SERVICIO Y AJUSTES Cambio de la manguera de aire La manguera de aire conectada a su compresor tiene una v lvula para su sistema integral de presi n en el extremo de trabajo de la manguera En caso de que fuese necesario el servicio o la reparaci n fuese requerida aseg rese de que la v lvula de regulaci n de la presi n se encuentre presente en la manguera de aire NO reemplace la manguera utilizando la manguera est ndar que no esta equipada con la v lvula reguladora de presi n El equipo de manguera apropiado para su compresor se encuentra disponible en Sears A AD A No permita que la manguera se retuerza ni sea perforada en momento alguno Esto es importante para evitar da os al compresor y para mantener el control de la v lvula reguladora de presi n meje ALMACENAJE 1 Coloque el interruptor On Off en la posici n OFF y desenchufe el conductor el ctrico 2 Libere toda la presi n del cabezal del compresor de aire y de la manguera girando la v lvula de presi n regulable a 10 PSI 3 23 SP Proteja el conductor el ctrico y la manguera de aire de da os dobl ndolos flojamente alrededor del compresor de aire Guarde el compresor de aire en un sitio limpio y seco A08593 GUIA DE DIAGNOSTICO DE PROBLEMAS AD Las fuentes de tensi n partes
38. vided If it does not fit the available outlet a correct outlet should be installed by a qualified electri cian Repairs to the cord set or plug MUST be made by a qualified electrician Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor and to prevent overheating If an extension cord must be used be sure it is aG3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the product good condition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gauge number decreases 12 AWG 10 AWG and 8 AWG may also be used DO NOT USE 16 OR 18 AWG Voltage and Circuit Protection Refer to the Parts Manual for the voltage and mini mum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If compressor is connected to a circuit protected by fuses use only time delay fuses marked D If any of the above conditions cannot be met or if operation of the compressor repeatedly causes inter ruption of the power it may be necessa