Home

Clear-Com ECLIPSE MATRIX Instruction manual

image

Contents

1. Hard Disk 500 MB free space Input Devices 3 5 inch Floppy Disk Drive CD ROM Drive Display Resolution SVGA User Entry Keyboard Mouse Ports 2 serial ports Network IEEE 802 3 Ethernet Card Operating Systems Windows XP Professional SP2 Server 2003 SP1 2000 SP4 Note For details of software requirements please refer to the ECS User Manual part no 810299 Power Supply Unit Format Euro Cassette Ouantity 2 per matrix Mounting Front Backplane Connectors Positronics AC Power Input IEC 1 per PSU Input Voltage AC 100 V to 240 V 50 60 Hz Power Consumption 400 W maximum Status Indicators LEDs viewable from front of rack Notice About Specifications While Clear Com makes every attempt to maintain the accuracy of the information contained in its product manuals that information is subject to change without notice Performance specifications included in this manual are design center specifications and are included for customer guidance and to facilitate system installation Actual operating performance may vary ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 1 3 1 4 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL GLOSSARY Bus A bus is the channel or path between the components in the matrix along which electrical signals flow to carry information from one component to the next In the Eclipse matrix the bus is located in the etched surface of the midplane Call Signal A call signal is an electronic signal sent from one station or
2. The following conditions trigger an alarm e If any of the voltages produced by the first power supply unit fall below normal levels If any of the voltages produced by the second power supply unit fall below normal levels fan internal matrix alarm condition activates a matrix relay to turn on an external alarm If the active CPU card exceeds a temperature threshold If either of the CPU cards is removed from the matrix If either of the matrix s two cooling fans stop operating f the temperature inside the Eclipse matrix exceeds a set threshold ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 11 MAIN ALARM LIGHT An alarm condition triggers the following events The red main alarm light flashes The matrixs internal alarm buzzer sounds Any installed alarm relay outputs switch to active the normally open contact closes and the normally closed contact opens When the alarm relay activates it can cause an externally connected device like a light or buzzer to switch on One of the six auxiliary red alarm lights may go on to more precisely indicate the source of the alarm condition These lights are discussed in further detail later in this section ALARM RESET BUTTON When you press the alarm reset button the following events take place even if the alarm condition has not been corrected The internal audible alarm buzzer stops buzzing Any wired relay contacts return to their inactive state If
3. each covered by a different warranty period The warranty periods are Cables accessories components and consumable items have a limited warranty of 90 days Headsets handsets microphones and spare parts have a limited warranty of one year UHF wireless IFB products have a limited warranty of one year UHF wireless intercom systems have a limited warranty of three years All other Clear Com and Drake brand systems and products including beltpacks have a limited warranty of two years The warranty starts at the time of the product s original purchase The warranty start date for contracts which include installation and commissioning will commence from the earlier of date of the Site Acceptance Test or three months from purchase TECHNICAL SUPPORT To ensure complete and timely support to its customers VGC s User Support Center is staffed by qualified technical personnel Telephone and email technical support is offered worldwide by the User Support Center The User Support Center is available to VGC s customers during the full course of their warranty period Instructions for reaching VGC s User Support Centers are given below Telephone for Europe Middle East and Africa 49 40 6688 4040 or 44 1223 815000 Telephone for the Americas and Asia 1 510 337 6600 Email vitec support AVC de Once the standard warranty period has expired the User Support Center will continue to provide telephone support if you h
4. from station M42 Input 8 422 Output into Matrix Q from station Audio Output from station Audio Input into station Audio Input into station Audio Input V V Audio Output into Nati from station 8522 Output Jr AA M4 Input from Matri into station RS 422 Output V V RS 422 Input from Mtr 8 into station Audio Input iu into Matrix Audio Output from Matrix Audio Output from Matrix Pair Audio output from Matrix to station Pair 2 R 422 data input from station to Matrix Pair 3 Audio input from station to Matrix Pair 4 N 422 data output from Matrix to station Figure 5 2 Wiring from the Matrix to an Analog Panel Using RJ 45 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 1 5 8 Single Pair Digital Single pair digital wiring is accomplished with double shielded 24 AWG conductor CAT 6E enhanced STP cable Pair 1 transmits and receives multiplexed digital and analog between the matrix and the panel Note Ensure that the select switch on the rear of the panel is in the correct position for the intended use ATT T568B Modular Jumpers Wired One to One Matrix Frame End Station End Pair 2 No Connection NC 1 1 No Connection NC 2 2 Pair 1 No Connection NC 3 3 Multiplexed Data Audio 4 4 Pal Multiplexed Data Audio 5 are 5 No Connection NC 6 6 No Connection NC 7 Fara 7 No Connection NC 8 8 Figure 5 3 Wiring from
5. matrix through the MVX A16 analog circuit card The following Clear Com intercom panels are compatible with the Eclipse Omega matrix system i Station family including expansion panels ICS 2003 intercom panels including expansion panels CS 52 and ICS 92 intercom panels including expansion panels CS 62 and ICS 102 intercom panels including expansion panels ICS 1008 and ICS 1016 intercom panels including expansion panels 4215E 4224E 4226E 4294E 4212E 4222E 4203E 4206E 4230E and 4230VE 4000 Series II panels VI2LD V24LD VI2PD V24PD VI2LDD VI2LDE and VI2PDE V Series panels Each of these panels is described in its own manual For a full description of the operation installation and maintenance of a panel refer to the appropriate panel instruction manual INTERFACES Interface modules convert the 4 wire signals of a central matrix port to other types of signals that communicate with devices such as telephones camera intercoms two way radios and so on In this way non wire devices can communicate with the central matrix Each interface module has hardware connectors to connect to both the central matrix and to the external device that communicates with the central matrix Most interface modules connect to the central matrix via shielded category 5 cable terminated with RJ 45 connectors The DIG 2 digital interface module however connects to the central matrix via double shielded 24 AWG conductor c
6. transmission but there will be no audio path between them Switching to the secondary ring will cause audio breaks or disturbances and temporary loss of crosspoint data The self healing mechanism is performed autonomously by the fiber linking card whereas the switch over between redundant cards and rings requires software or operator intervention ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL If two adjacent nodes are lost on one ring and the other ring has a similar fault this will be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed nodes healing the ring The configuration software will report the failure correctly as two failed nodes If two non adjacent nodes are lost on one ring and the other ring has a similar fault the nodes adjacent to the failures will loop back their connections to the failed nodes healing the ring into 2 separate smaller rings The configuration software will report the failure Note that in this instance the two sub rings will be dependent on their Ethernet connections for configuration and data transmission but there will be no audio path between them Fiber Optic Linking Card Failure This will be handled as for loss of a single node above The configuration software will report the failure FAULT TOLERANCE Dual Card Set Redundant System Full Redundancy In the event of single or multiple cable fault or loss of node conditions occu
7. 3 volt supply is present and supplying power to the card ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 1 RESET BUTTON 2 POWER SUPPLY LIGHTS When lit 3 3 V power supply is on 3 STATUS LIGHTS 8 yellow lights one per port When on light indicates 1 There is a device connected to the port 2 Communications are running properly between the port and the card 4 LAN DATA LIGHT The green LAN DATA light illuminates to indicate data is passing through the ethernet port 5 LAN LINK LIGHT The amber LINK light illuminates to indicate a connection on the LAN port Figure 4 1 Front E Que Card 4 3 3 Status Lights When lit a status light indicates successful communication between the E Que card and a connected device such as an active antenna or splitter Each of the E Que card s 8 yellow status lights corresponds to one of 8 ports to which devices can be connected 2 LAN Data Light The green LAN DATA light illuminates to indicate there is data passing through the ethernet port LAN Link Light The amber LAN LINK light illuminates to indicate a connection to the LAN port E QUE CARD REAR CONNECTIONS The F Que card rear card contains eleven RJ45 connectors 8 E1 T1 ports 2 DECT sync ports and a LAN port 4 4 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL LAN Port RJ45 T DECT Ref in La RJ45 DECT Ref out RJ
8. 4 Gently close both ejector tabs at the same time which will propel the card into the backplane connectors To remove a CPU card from the matrix 1 The two card ejector tabs located at the top and bottom of the CPU card hold the card in place in the matrix To remove a card open the two ejector tabs at the same time until the card unseats from its backplane connectors 2 Pull the card out of the matrix STATIC SENSITIVITY A circuit card s components include CMOS chips that are sensitive to static electricity Before touching a card with your hands touch a grounded metal object such as any unpainted surface on the matrix to dissipate static electricity When handling a card be careful not to bend any of the card s connector pins or component leads Store spare cards in electrically insulated packaging such as anti static heavy duty plastic bags or in unused port card slots in the matrix HOT PATCHING Port and expansion circuit cards are hot patchable and self initializing meaning that a faulty card can be removed and replaced while the system is ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 5 5 6 powered having no effect on any part of the system operation except to the card s assigned sixteen ports Communication to a card s connected devices will be interrupted when that card is removed from the matrix When the card is replaced communication is restored SLOT NUMBERING Each port and expansion card h
9. are servicing the battery make sure that the jumper on CONO is connecting pin 2 common to either pin I on or to pin 2 off If the common is left floating the CPU may behave unpredictably For example the microprocessor may reset itself intermittently VERIFYING THE SHIPMENT When you receive your Eclipse Omega system inspect the boxes for shipping damage Report any shipping damage to the carrier Your Eclipse Omega distributor is not responsible for shipping damage Check the packing list and verify that you received every item on the list Save all P g y y packing materials in the event you need to return any items UNPACKING THE SYSTEM When you receive your Eclipse Omega system the circuit cards power supplies and rear connector panels are pre installed in the matrix chassis You need to supply A standard 19 inch rack in which to install the matrix A personal computer to run the Eclipse Configuration System ECS The Eclipse Configuration System runs on Windows XP Windows Server 2003 and Windows 2000 ECLIPSE OMEGA INSTRUCTION MANUAL Shielded category 5 cables to connect to panels and interfaces INSTALLING THE ECLIPSE OMEGA MATRIX The following overview gives you a summary of the steps required to install an Eclipse Omega matrix More detailed information on each step is provided in the sections that follow To install an Eclipse Omega matrix 1 Remove the Eclipse Omega matrix chassis from its shipp
10. card are lit the electric current has successfully traveled from the matrix s power supplies to the CPU card If a power supply light is not lit on a component the electric current has not reached that component for some reason Knowing where the current has stalled helps to identify the component that needs repair For example if all of the power supply lights on all cards do not light the electricity supply may have given out either in the power supplies themselves or in the matrix s backplane connectors A faulty connector on the backplane or a crack in the backplane can cause all of the matrix s power supply lights to go out because the path on which the electric current is traveling has been blocked This is a rare problem but one to consider as a possibility Repairing the problem in this case would involve determining whether the problem is in the power supplies or the backplane connectors When you identify a problem in the power supplies the backplane connectors or the circuit cards you can then swap out the suspect component with a properly functioning component to see if the problem is repaired ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 6 3 Specific Troubleshooting Examples Troubleshooting more specific problems becomes easier when keeping these general principles in mind The following examples describe specific problems and suggested solutions Problem All of the power supply lights do not illuminate on one
11. ea sect Vr a TE E 2 9 Power Supply Description av EENDE kine ut Cad asa bc MR era 2 10 Diagnosing Power Supply Problems 00000 eee eee 2 10 Conditions that Cause an Alarm is idque od Bek ay ad bt dea Rote per 2 11 Main Alarm Light i2 atl ocd aol veo elc ves ia 2 12 Alarm Reset Buttons eile Ses Kd hays PU iets EE a E OR a Ero 2 12 Auxiliary Alarm Lights Me ode He de de Ee SR de RES 2 12 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL i il External Alarm Ext Alarm 2 0 SS SS eee orsa 2 12 Temp Alarmna EE N SE ES vea Den ah EE oe 2 12 Lan bail Alarmi 128 ER Vox aura SE Ee bol EE bed Geo EE 2 13 PSEDSPAU ES EED EE DE GE epe dh euet 2 13 DS DAP weeds s ee Ta EAD d cys Wt alent tee it DE AE 2 13 Fan On Indicator iy dio Seas eevee game Ghee Wine Rae ki 2 14 Power Supply Lig lite naiewe scito ay heel aee Det dee Debs 2 14 Connecting the Matrix us oie Lucae ath RA se RA Ne dis De dyes 2 15 Connecting the GBU Card od EERS ble s rade Ee ey oe 2 16 GPI RLY Interface Connectors ord i ceo das b poca Ed aa mies 2 16 KEER AR Idee c t t eS etie 2 17 Alarm VO Connector Sua ca Ebrei e pend dq Pb aged ds acr d 2 17 General Purpose Outputs Connector GP OUT 2 17 General Purpose Inputs Connector GP IN 0 0 2 0 0 00008 2 17 Local Area Network 1 Connector CLAN 1 0 0 00005 2 18 Local Area Network 2 Connector CLAN 2 0 0 0 0 00000005 2 18 Connecting Port Cards ix Sosa o
12. interface to another A call signal can be audible and or visual Typically a call signal is sent to get the attention of a station operator who may have turned down their intercom speaker s volume or removed their headset It can also be sent to activate an electronic relay Category 5 cable EIA TIA 568 category specification relating to network cabling Shielded category 5 cabling is required for Eclipse matrix wiring Central Matrix The term central matrix is used to differentiate the central hardware and software of the intercom system from the connected audio devices The central matrix consists of 1 the metal housing for the circuit cards and power supplies 2 the circuit cards 3 the power supplies 3 the rear panel connectors which connect the matrix s hardware to stations and interfaces Destination A device such as an intercom station beltpack or interface to which you send audio signals The device from which you send audio signals is called a source Duplex All real time communication between individuals talking face to face is full duplex meaning that you can both talk and listen simultaneously The Eclipse Omega matrix provides full duplex audio Eclipse Configuration System Software program that guides the operation of the central matrix circuit cards and connected stations Ethernet International standard which describes how information is transmitted across a network Provides for the efficient or
13. meee RIS 6 1 Fail Safe Modess rss nl N RE RI BENE ae Baers GR AMD 6 1 Dual Independent Power Supplies 0 0 cece cee eee 6 2 Power Supply Alarm Output ous sso d d ve Dd ee lee SUP 6 2 Hot Patchability iu esci ak ete OG dede EX Db dte RC dont eb ud 6 2 Omnboaab Processo ER s e et bos bate e e 6 2 Fail Safe Communication oc tiara ae ee nea donates ke Ee 6 2 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL ii iv Troubleshooting 2 2 oos eode tiie tae M a i sn M Wile EE All 6 2 Troubleshooting Power Supply Problems lees eere 6 3 General Principles s iuo ed nene DE ee tok ead o Pu bct aoa 6 3 Specific Troubleshooting Examples i525 X52 DE ap rer ra 6 4 Troubleshooting Data Problems ek eee oS p REL Rena 6 6 General Principles sss entei EE Sora coc d eae aca a ob tt d iae S 6 6 Specific Troubleshooting Examples is soseer oe WE ER ee ad ees 6 7 System Block Diagram oiu iure dard AE dore ER e Re ar dU o ah enun 6 7 SPECIFICATIONS og manae OS n Ret Dt dy me 1 1 Omega Matrix Technical Specifications 1 0 0 eee eee eee eee 7 1 GLOMAR MTM T 8 LIMITED WARRANTY n mee bax 9 Warranty Peto cu uh n pete nepi bee UR ER ae See ERR diu da 9 1 Technical SUpport e raset so o Etre ea cage EE Ae RR RAE Pra AE AU PA 9 i Warranty Repairs and Retire x vues a bac we cath anew dI Et p dU 9 ii Non Warranty Repairs and Retirtis4 9 ios nice yee DNE cheats 9 ii Extended Watrauty d us oe esce owe e t eee er Rs IE goa 9 ii EPI MEHR RO IRR MN NIM
14. mode all eight E1 T1 ports can be used to connect up to eight antennas If the E Que card is configured to support splitters only two ports are active ports 1 and 5 allowing a maximum of two splitters to be connected Each splitter can support up to five antennas There connections schemes are illustrated below ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL E1 T1 E1 T1 E1 T1 E1 T1 E Que Rear E1 T1 E1 T1 E1 T1 E1 T1 Figure 4 3 E Que Card Antenna Connection Antennas EX EX CS CS EX EX C 4 Antennas JA A Antenna Splitter E1 T1 Port 1 NY Matrix aa r ea Vv Port 5 E1 T1 Antenna Splitter lt EK EX EX Figure 4 4 E Que Card Splitter Connection Each antenna can handle up to five beltpacks simultaneously and switch service between antennas under control of the matrix as the beltpack user moves around the site Where multiple matrices are networked together with antennas or splitters connected to E Que cards on more than one matrix the E Que cards should have the DECT Sync links between matrices to ensure the correct operation of the FreeSpeak CellCom system Multiple E Que cards within a single matrix do not need to have external DECT sync cables connected as the signal uses the backplane 4 8 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL LAN Figure 4 5 Multiple Matrices with DECT Sync Interconnect All connections are made usi
15. the Matrix to a Digital Panel Using RJ 45 Note This wiring diagram refers to the Digi 2 unit only WIRING CPU CARD INTERFACES The central processor unit CPU card holds the circuitry for connecting to and communicating with the following interfaces An external personal computer Alarm inputs and outputs Eight general purpose inputs GPIs Eight general purpose outputs GPOs or relays Two separate local area network LAN connections for Ethernet based communication with a network An external GPI RLY interface ECLIPSE OMEGA INSTRUCTION MANUAL D GPI RLY Interface Connector R 45 G Alarm 1 0 Connector female 9 pin D type RS 232 Connector female 9 pin D type 2 General Purpose Outputs Connector 4 male 25 pin D type General Purpose Inputs Connector female 25 pin D type 6 LAN Connector RJ 45 7 LAN 2 Connector RJ 45 Figure 5 4 CPU Card Interface Connectors QD GPI RLY INTERFACE CONNECTOR For wiring pinout information for GPI RLY interfaces see the Relay Interface Module RLY 6 Instruction Manual and the General Purpose Inputs GPI 6 Instruction Manual in the set of manuals that came with your Eclipse system 2 RS 232 DB 9 CONNECTOR The DB 9 connector labeled RS 232 connects the Eclipse matrix to an external computer To connect a computer to the matrix run cable from the matrix s RS 232 connector to the PC s serial port The maximum recommended
16. these relays are connected to external alarm lights or alarm buzzers those lights or buzzers shut off If the original alarm condition still exists the red main alarm light on the matrix s front panel continues to flash The red main alarm light only stops flashing when all original sources triggering the alarm are corrected If a new alarm condition or conditions occur before the original alarm conditions are corrected the internal buzzer and relay contacts will not reactivate They will only reactivate after all original alarm conditions are corrected AUXILIARY ALARM LIGHTS When an alarm condition occurs any of the six auxiliary alarm lights may switch on in addition to the main alarm light to help you diagnose the alarm condition The following sections describe the six auxiliary alarm lights External Alarm Ext Alarm The external alarm labelled EXT ALARM light switches on to indicate that an alarm condition has triggered the built in relay outputs to turn on any externally installed alarms such as lights or bells You connect the external alarm to the matrix through the 9 pin D type connector on the matrix s rear panel labeled Alarm I O Temp Alarm The red temp alarm light switches on to indicate one or both of the following The active CPU card has detected a temperature in the matrix above a threshold ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL One of two CPU cards has been removed fr
17. upper connector on the rear panel Care should be taken when connecting or disconnecting the cables to ensure that they are connected correctly and not reversed Note Normally a protective plug is fitted to the fiber connector sockets to protect them from damage or the entry of foregn materials These should only be removed in order to fit the fiber optic cable and replaced if the cable is unplugged CONFIGURING A FIBER OPTIC CONNECTION There are a number of ways that optical connections can be made between systems depending on the level of redundancy required When a break occurs in the fiber ring a solid red status light will be shown at the fiber card downstream from the break and the link status LEDs may show amber Other fiber cards will intermittently show red as the ring attempts to recover If the system layout is displayed by ECS the faulty links are shown in red In order to diagnose faults or switch between primary and secondary rings or between primary and backup fiber linking cards the My Systems in ECS must be used Ensure that the current configuration is open and click on Live Status in the My Systems toolbar to display the current system state This will allow the operator to intevene to alter the system configuration as required For details of ECS please refer to the ECS instruction manual part number 810299 SIMPLEX FIBER CABLING Single Card Set Redundancy In this case each Matrix Frame contains one fibe
18. 45 Port 1 RJ45 Port 2 RJ45 Port 3 RJ45 Port 4 RJ45 Port 5 RJ45 Port 6 RJ45 Port 7 RJ45 Port 8 RJ45 Figure 4 2 Rear E Que Card When multiple E Que cards are fitted in a rack one of the cards generates a clock signal which all othe cards lock to to ensure that all antennas remain in sync The system is designed such that the leftmost card seen from the front is always the one which generates this signal This means that if the leftmost card is removed or a new card is fitted to the left of existing cards the antennas will lose lock for a few seconds as the cards re configure themselves and a new card starts generating the sync signal ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 4 5 4 6 Where multiple connected matrices are used containing E Que cards the DECT reference ports are connected as a daisy chain between the matrices to ensure that the DECT signals are synchronised through all the E Que cards present in the matrices The LAN port is used for diagnostic purposes E QUE CARD APPLICATIONS The E Que card may be used to connect FreeSpeak CellCom antennas and splitters to an Eclipse matrix system FREESPEAK CELLCOM APPLICATION The E Que cards can be configured for FreeSpeak CellCom use in two modes depending on whether antennas or splitters are to be connected If the E Que card is configured in Antenna
19. ANI and LAN connectors have standard Ethernet pin assignments LANI and LAN2 Ethernet RJ 45 Connectors 87654321 OR wa L1 est n 3 we 3 we Nr MT EN sa 1 Figure 5 13 Pin Assignments for LAN1 and LAN2 Connectors ECLIPSE OMEGA INSTRUCTION MANUAL Due to the complexity of the system field service generally should be limited to isolating the specific component with the problem MAINTENANCE INTRODUCTION The Eclipse Omega matrix system connects a complex network of microprocessor controlled devices Due to the complexity of the system you should limit field service to isolating a problem to the specific circuit board that may be causing the problem Once the circuit board has been identified it can be either repaired or replaced ROUTINE MAINTENANCE RECOMMENDATIONS MAINTAINING THE MATRIX Because the matrix has moving air in it the entire matrix should be cleaned at least once a year To clean the matrix shut off AC power remove all cards and use compressed air to remove any dust buildup in the matrix itself Clean all cards with a brush to remove dust buildup Q WARNING Care should be taken not to induce a static discharge in the cards Use of a grounding wrist strap is recommended Ifa grounding wrist strap is not available touch an unpainted metal surface on the matrix chassis periodically to neutralize static electricity RECOMMENDED SPARE PARTS To facilitate quick re
20. BE DEFECTIVE WITHIN THE WARRANTY PERIOD AS AFORESAID This warranty does not cover any damage to a product resulting from cause other than part defect and malfunction The VGC warranty does not cover any defect malfunction or failure caused beyond the control of VGC including unreasonable or negligent operation abuse accident failure to follow instructions in the manual defective or improperly associated equipment attempts at modification and repair not approved by VGC and shipping damage Products with their serial numbers removed or defaced are not covered by this warranty This warranty does not include defects arising from installation when not performed by VGC lightning power outages and fluctuations air conditioning failure improper integration with non approved components defects or failures of customer furnished components resulting in damage to VGC provided product This limited warranty is not transferable and cannot be enforced by anyone other than the original consumer purchaser This warranty gives you specific legal rights and you may have other rights which vary from country to country WARRANTY
21. E 9 iii ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL FIGURES The Eclipse Omega Matrix Assembly retenciones e edens 1 2 Front Panel of Eclipse Omega Matrix s ssssssrsrsrsersrsrsrrserserssrsrsrrrrssrsrn Eas res 2 1 CPU Cards Front Panel Lights and Controls sesse dest o reet 2 4 Port Card s Lights and Controls yes Es SG iere ee rois 2 8 Power supply modules front door MEER Ri SERE seed baas DRS be ep en rna 2 11 The Eclipse houses three types of rear connector panels 2 15 CPU Cards Rear Connector Panel is Re Re ee utens 2 16 Front Fiber ARE esse es de AN ee RES ee Ee eg Ee boo sis ds 3 3 Rear Fiber Cardi ie EDE EG ED EE Re Ee ba ee ee b Re N De ce RUD Lcd 3 5 Ring Topology Single Card Set Redundancy etes 3 7 Ring Topology Dual Card Set Redundancy sess 3 10 Front E Que Card iu eae eene uit on doe tet tet er de ecu 4 3 Rear E Que Card RSS Ee RURSUS 4 5 E Que Card Antenna Connection iese ses se ek ee eren 4 7 E Que Card Splitter Connection vt ee ee ke es SEE etai enn 4 8 Multiple Matrices with DECT Sync Interconnect eee 4 9 CPU card with detail of CON9 jumper plugs 522212 eodein ederent 5 1 Wiring from the Matrix to an Analog Panel Using RJ 45 5 7 Wiring from the Matrix to a Digital Panel Using RJ 45 iese ses se see se ee 5 8 CPU Card Interface Connectors Sep aeneis Ge Ke Ee Se Se beri cedet pb 5 9 Wiring the Matrix DB 9M to a DB 9F Computer Serial P
22. ELAY 3 RELAY 4 Common Normally Closed Normally Open e Common Normally Closed Normally Open Q 1 Common Normally Closed Normally Open O Common Normally Closed Normally Open Digital Ground 30 VDC at Ampere Common Normally Closed O Normally Open Common Normally Closed Normally Open Common Normally Closed Normally Open HA Common Normally Closed Normally Open Figure 5 9 Pin Configuration of the General Purpose Outputs Connector 5 GENERAL PURPOSE INPUTS CONNECTOR GP IN The DB 25 connector labeled GP IN connects the matrix to eight local general purpose inputs GPIs RELAY 5 RELAY 6 RELAY 7 RELAY 8 The general purpose inputs operate in one of two modes the opto isolated mode or the unisolated mode The opto isolated mode requires the externally connected equipment to provide the current to power the general purpose input The non isolated mode does not require that the externally connected equipment powers the general purpose input The current is supplied by a voltage output on the GP IN connector ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL EXTVIN To select a mode move the J1 jumper on the CPU rear card to one of two positions The J1 jumper is located on the inner matrix side of the DB 25 connector For opto isolated mode fit the J1 jumper across pins 1 an
23. Figure 6 The following sections describe each connector The Installation Chapter of this manual gives pin assignments for each connector and row number Note A matrix only requires one rear panel CPU card because whichever of the two front installed CPU cards is acting as master will work in conjunction with this card All other cards however require their own rear connector panel O GPI RLY Interface Connector R 45 RS 232 Connector male 9 pin D type 2 G Alarm 1 0 Connector female 9 pin D type General Purpose Outputs Connector General Purpose Inputs Connector male 25 pin D type female 25 pin D type LAN Connector RJ 45 7 LAN 2 Connector RJ 45 Figure 2 6 CPU Card s Rear Connector Panel D GPI RLY INTERFACE CONNECTOR The RJ 45 socket labeled GPI RLY Interface connects the CPU card to a GPI 6 or RLY 6 card The GPI 6 provides six general purpose opto isolated logic inputs The RLY 6 card provides six single pole double throw relay outputs Both card types mount in either an IMF 3 interface frame or an IMF 102 interface frame You can operate up to ten GPI 6 or RLY 6 cards at one time 2 16 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL from the matrix by daisy chaining the cards together Each card has an IN and an OUT connector for this purpose The RLY 6 and GPI 6 cards connect to the GPI RLY interface connector using shielded category 5 cable For more information about the GPI 6 a
24. K DIAGRAM A INTERFACE TO LAN1 LAN2 GPI RLY amp GPI GPO GPI RLY ANALOG 2 4 WIRE RS232 SERIAL amp STATION INTERFACES ALARM INTERFACES INTERFACES z 5 Y y POWER POWER m E E T m 7 m SUPPLY SUPPLY a T 2 2 CONN CONN 3 z 2 EQ Fibe Net m CONFIG MVX16A MVX16A ue Z 2 saaie a d REAR REAR REAR rear card rear card 3 m gt 5 CARD CARD CARD optional optional 9 Ed Z o o o o gt gt gt 5 I D 3 o INTERFACE MODULE BACKPLANE MAIN BACKPLANE z E i E ES E Que Fibre Net APER S ER gt CONFIG CONFIG MVX16A MVX16A front card front card ALARM PSU PSU o B CARD CARD CARD CARD optional optional CARD o o i 3 3 o Figure 6 1 System Block Diagram ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 6 1 6 8 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL SPECIFICATIONS OMEGA MATRIX TECHNICAL SPECIFICATIONS 0 dBu is referenced to 0 775 volts RMS Matrix Capabilities Ports per Port Card 16 Maximum Port Cards 15 Maximum CPU Cards 2 included Maximum Fibre Expansion Cards 2 Maximum E Que Expansion Cards 4 Maximum Power Supply Units 2 included Maximum RJ 45 Ports per Matrix 240 Mechanical Height 10 6 inches 267 mm or 6 RU Width 19 inches 482 mm Depth 16 inches 410 mm Front Card Depth 300 mm Weight 20 to 35 kg Power Consu
25. MD Glear Gaar p COMMUNICATION SYSTEMS ECLIPSE OMEGA MATRIX FRAME AND CIRCUIT CARDS INSTRUCTION MANUAL Eclipse Omega Matrix Instruction Manual 2007 Vitec Group Communications Ltd All rights reserved Part Number 810290Z Rev 7 Vitec Group Communications LLC 850 Marina Village Parkway Alameda CA 94501 U S A Vitec Group Communications 7400 Beach Drive Cambridge Research Park Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806 Hua Bin Building No 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing PR China 100022 Clear Com CellCom FreeSpeak and the Clear Com Communication Systems logo are registered trademarks of The Vitec Group plc CONTENTS THE ECLIPSE OMEGA MATRIX SYSTEM AN OVERVIEW I I FOA UCS rg st ee E eov OE ME ER ONE red A os 1 1 The Eclips Omega MAN score EN disini Sie d cerent dipl 1 2 Matrix Assembly s eet oot I ete V p cg 1 2 Matrix Chassis a v basia e en einen ee Ep Sup Ea Db R DOs afa d as 1 3 Circuit Cards Mc cv 1 3 PE Cites uec AR RE EE ER EE DERE 1 3 Port Cards Loco Ee oe kate La ate ER NE EE od fe aR ats 1 3 TUDEr aid uuu i aca roce a ral ace M RE ORR a aia RUE 1 4 E Que Card OE OE EE ER ee deb banded 1 4 Power Supplies c sas pe segt EE RED DE SR PERE EER DE IR RENE ee war 1 4 MVX Rear Panel Connectors Ports 0 0 00 cece cece eas 1 4 Eclipse Configuration System ECS ies pe des ae io ee Ae era 1 4 Inte
26. NG FIBER CARD DESCRIPTION E FIB fiber cards connect Eclipse matrices together to provide a high speed dual redundant link to transfer audio samples and data between systems These connections can be configured in various ways to provide protection against the loss of a link or a node Each fiber card link consists of a front card with various status indicators and a rear card with two Duplex LC Terminated fiber optic connectors TXVRA and TXVRB The fiber cards use Simplex fiber optic cables Each fiber optic front card has a reset button status LEDs for power processor function card status link status and link activity The link status and activity LEDs indicate whether there is activity on a link whether the card is transmitting on a link and the error state of a link Normally fiber cards should be fitted in slots 14 and or 15 of an Omega matrix If fiber cards are fitted to any matrix in a linked system all the linked matrices must be reset to ensure that all matrices correctly recognise the new hardware E FIB FIBER CARD FRONT PANEL LIGHTS AND CONTROLS D Reset Button Pressing the reset button causes the card and all links to momentarily stop their current activity and to restart The card s frame data light goes off when the reset starts and comes back on when the reset is complete During the reset configuration information downloads to the card and its connected matrices from the CPU card If the entire system is o
27. Note Under normal operating conditions it is not necessary to perform a full reset Technical personnel might perform a full reset if they believe that the CPU card is operating incorrectly as a result of corruption of the microprocessor s internal data or instruction sequence ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL PORT CARD DESCRIPTION Port cards connect the central matrix to intercom panels and interfaces In a linked system port cards connect trunk lines The analog card designated the MVX A16 supports normal audio feeds user panels and trunk lines All cards contain a voice detection mechanism VOX that you program from the ECS configuration software VOX detection allows you to know when the audio on a particular channel has exceeded a threshold This is particularly useful for channels that are inactive periodically so that you are visually cued when audio appears on the line Each port card has two system status lights A port card s FRAME DATA light illuminates to indicate the card s successful communication with the CPU card A port card s STATUS light illuminates to indicate a failure in communication between the port card and the CPU card When all port cards are lined up in the matrix the system status lights form a horizontal row showing the overall state of the system PORT CARD FRONT PANEL LIGHTS AND CONTROLS O Reset Button Pressing the reset button causes the card and all connected audio dev
28. The following procedure helps you isolate where the trouble is occurring Check the power supplies alarm lights If the alarm lights are indicating a problem with the power supply swap it out with a new power supply If this repairs the problem the problem was in the power supply If the problem persists even after the power supply has been replaced the problem is in the backplane Send the matrix back to Clear Com for repair or replacement In the meantime another matrix can be substituted for the damaged one Clear Com will send you a substitute matrix to use while the damaged one is being repaired ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 6 5 6 6 TROUBLESHOOTING DATA PROBLEMS General Principles The other type of problem that can occur in the system is when data is not flowing properly between the program software the circuit cards and the attached panels and interfaces A troubleshooting sequence in this situation would be to first check cabling then reset the card or panel then reset the entire system Port Card Reset Button Resetting the port card causes the configuration information for the card and its attached devices to reload to the card from the CPU card s operational memory located in its microprocessors RAM thus clearing up any corruption of data that may have occurred in the port card s microprocessor The card and all connected panels and interfaces momentarily stop their current activity and restart
29. The reset button must be pressed for more than two seconds to take effect If the entire system is operating except for one port card or one or more panels connected to the card press the reset button for that card only Note This button is slightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button CPU Card Reset Button When you reset the CPU card by pressing its reset button the card s non volatile RAM reloads all configuration information to the card s microprocessor Resetting the card clears any corruption of data in the card s microprocessor The card momentarily stops its current activity and restarts The same system configuration that was active before you reset the card will be active after you reset it Note The reset button is slightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button CPU Card Full Reset Button When you press and hold the full reset button and simultaneously press the reset button the system performs a cold restart All cards in the matrix reset regardless of any system preferences in the program software All audio devices connected to the cards such as panels and interfaces reset as well When the cards and connected audio devices reset they momentarily stop their current activity and restart During this process con
30. WER SUPPLY LIGHTS When lit 12 V power supply is on When lit 12 V power supply is on When lit 5 V power supply is on When lit 3 3 V power supply is on 3 ACTIVE LIGHTS 16 yellow lights one per port When on light indicates 1 There is a device connected to the port 2 Communications are running properly between the port and the card 4 VOX LIGHTS 16 green lights one per port When on light indicates I A VOX threshold for the port is programmed in the system software 2 Audio input on the port has exceeded the VOX threshold 5 FRAME DATA LIGHT The green frame data light illuminates to indicate successful communication between the port card and the CPU card 6 STATUS LIGHT The red status light illuminates to indicate a failure in communication between the port card and the CPU card Figure 2 3 Port Card s Lights and Controls ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 Active Lights When lit an active light indicates successful communication between the port g card and a connected device such as an intercom panel or interface Each of the port card s 16 yellow active lights corresponds to one of 16 rear panel connectors or ports to which audio devices can be connected a VOX Lights When lit a VOX light indicates that the audio level on a connected device such as an intercom panel or interface has exceeded a preset threshold You set the threshold audio level throug
31. X INSTRUCTION MANUAL MATRIX CHASSIS The matrix chassis is a metal rectangular box which measures six rack units high and 19 inches wide 26 9 cm x 48 3 cm It has slots for 17 circuit cards and 2 power supplies RJ 45 and fiber optic connectors are located on removable plates on the rear of the chassis These connect the circuit cards to intercom devices and media such as panels interfaces 4 wire audio equipment wireless equipment and fiber optic cables CIRCUIT CARDS The matrix holds two types of circuit cards system cards and port cards The cards slide vertically into the front of the matrix and connect to the matrix s backplane CPU Card The CPU card is the master configuration card in the Eclipse Omega system It provides the serial data and Ethernet connection to the connected PC computer The CPU card also coordinates the data flow between the other cards in the system allowing them to communicate with each other The computer memory chip which stores four complete system configurations is located on the CPU card so that a selected configuration can be retrieved and activated directly from the card Like the other cards in the system the CPU card fits in the Eclipse Omega matrix The card fits vertically in a six rack unit 6 RU space and connects to the matrix s backplane One CPU card is required for each Eclipse Omega system Two cards can be installed to provide redundancy in the case of outages or repair need
32. as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Please familiarize yourself with the safety symbols in Figure 1 When you see these symbols on an Eclipse Omega matrix system they warn you of the potential danger of electric shock if the system is used improperly They also refer you to important operating and maintenance instructions in the manual ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL iii CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol alerts you to the presence of uninsulated dangerous voltage within the product s enclosure that might be of sufficient magnitude to constitute a risk of electric shock Do not open the product s case This symbol informs you that important operating and main tenance instructions are included in the literature accompanying this product Figure Safety Symbols EMC AND SAFETY The Eclipse Omega matrix meets all relevant CE FCC UL and CSA specifications set out below EN55103 1 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emissions EN55103 2 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional u
33. as circuitry to support 16 ports A grid printed on the matrix s rear panel gives the numbering scheme for the ports CONFIGURATION When a port card is physically installed its ports must be assigned functions from the Eclipse Configuration System ECS Refer to the Eclipse Configuration System Instruction Manual for more information VERIFYING PORT CARD INSTALLATION You can check the operating status of the matrix by viewing the front panel status lights The following lights indicate that a port card has been properly installed in the matrix When lit the four power supply lights indicate that the associated power supplies are operating properly The four lights are 12V 12V 5V and 3 3V The column of 16 yellow lights labeled active corresponds to the card s 16 ports When lit an active light indicates that there is a device connected to that port and that communication is running properly between the card and the device The column of 16 green lights labeled VOX corresponds to the card s 16 ports When lit a VOX light indicates the audio level on that port s connected audio device has exceeded a threshold You set the threshold audio level for that port s connected audio device in the ECS configuration software The green frame data light illuminates green when information has successfully passed between the CPU card and the port card The red status light illuminates wh
34. ategory 6 enhanced CAT GE STP cable ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 1 5 The type of cable used to connect the interface module to the non 4 wire device varies with the device Each of these connections is described more fully in the individual manual for each interface The following interface modules are compatible with the Eclipse Omega matrix TEL 14 telephone interface module CCI 22 dual party line interface module FOR 22 four wire interface module GPI 6 general purpose inputs interface module RLY 6 relay general purpose outputs interface module AES 6 digital interface module DIG 2 digital interface module transparent to the system configured in ECS as the type of panel it is connected to Each of these interfaces is described in its own manual For a full description of the operation installation and maintenance of an interface refer to the individual manual for that interface ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL OPERATION THE ECLIPSE OMEGA MATRIX AND CIRCUIT CARDS The Eclipse Omega matrix chassis houses the circuit cards power supplies and connectors that form the central hardware of the system Measuring 19 inches wide and 6 rack units high 48 3 cm x 26 9 cm the matrix chassis installs in a standard equipment rack Various types of Eclipse Omega circuit cards perform unique functions System cards control overall system operation port cards control the operation of connected panels and i
35. ave purchased an Extended Warranty For latest contact information please refer to the Service and Support section at www clearcom com WARRANTY REPAIRS AND RETURNS Before returning equipment for repair contact a User Support Center to obtain a Return Material Authorization RMA VGC representatives will give you instructions and addresses for returning your equipment You must ship the equipment at your expense and the support center will return the equipment at VGC s expense For out of box failures use the following contact information Europe Middle East and Africa Tel 44 1223 815000 Email customerservicesEMEA vitecgroup com North America Canada Mexico Caribbean amp US Military Tel 1 510 337 6600 Email customerservicesUS vitecgroup com Asia Pacific amp South America Tel 1 510 337 6600 Email customerservicesAPAC vitecgroup com VGC has the right to inspect the equipment and or installation or relevant packaging For latest contact information please refer to the Service and Support section at www clearcom com NON WARRANTY REPAIRS AND RETURNS For items not under warranty you must obtain an RMA by contacting the User Support Center VGC representatives will give you instructions and addresses for returning your equipment You must pay all charges to have the equipment shipped to the support center and returned to you in addition to the costs of the repair EXTENDED WARRANTY You can purchase an exten
36. card and the CPU card ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Frame Data LED The red status light illuminates to indicate a failure in communication between the fiber card and the CPU card FIBER CARD REAR PANEL LIGHTS AND CONNECTIONS The fiber card rear card contains a single power supply indicator LED and two fiber connectors Class Laser Product When lit 3 3 V power supply is on Secondary Fiber Port NOTE Primary and Secondary Fiber ports are reversed with respect to the front panel indicators Take care when unplugging the cables to unplug the correct cable Transceiver Lasers 9 Primary Fiber Port Figure 3 2 Rear Fiber Card ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 5 3 6 The fiber optic cable for the primary and secondary circuits are plugged into the appropriate ports Eye Safety This laser based single mode transceiver is a Class 1 product It complies with IEC 60825 1 A2 2001 and FDA performance standards for laser products 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice 50 dated July 26 2001 Note The order of the fiber optic cable connections is reversed between the front and rear panels On the front panel the primary connection is the upper set of indicators but on the rear panel it is the lower connector Similarly the secondary connetion is the lower set of indicators on the front panel but the
37. d 2 For non isolated mode fit the J1 jumper across pins 2 and 3 Note It is recommended that you set the connector to the fully opto isolated mode Opto Isolated Mode Figure 5 10 shows the opto isolated connection 7 24V EXTVIN c D 10uF_25V BYG22D LM78LOSACM ala I0uF 10V EXTERNAL INPUT R29 1 5K EXTERNAL INPUT 2 3V o R 33K2 INPUT I INPUT 2 R30 1 5K MOCD207 M Figure 5 10 Opto Isolated Connection to Eclipse Omega GPI Connector In this mode a DC voltage of between 7 and 24 volts is required at the EXTVIN pin with relation to the EXTVIN pin To cause an input to detect an active signal you must send current from the relevant input pin The external device should draw no current to cause an inactive input and at least 5 mA to cause an active input The opto isolator drive line contains a 1 5 kOhm resistor to limit the current through the opto isolator You can therefore connect the input pins directly to the EXTVIN level to cause an active input The voltage level at the external input pin should not be allowed to go below EXTVIN or above 6 V with respect to EXTVIN Non Isolated Mode Figure 5 11 shows the non isolated connection 3V3 o R29 1 5K 3V3 INPUT I EXTERNAL INPUT I M o o R R 332 332 INPUT 2 EXTERNAL INPUT 2 R30 ISK MOCD207 M Figure 5 1 1 Non Isolat
38. d in modular removable panels Each panel is associated with a corresponding front panel circuit card Eclipse Blank Panels are installed Port Card Rear Panels have The CPU Card Rear Panel in unused portions of the 16 RJ 45 connectors each houses connectors for a computer frame to connect to intercom stations computer network interfaces alarms and and interfaces other matrices Figure 2 5 The Eclipse houses three types of rear connector panels There are five types of rear connector panels e A CPU card rear panel holds the various connectors associated with the CPU card such as the RS 232 connector for the configuration computer This panel s connectors are discussed in the next section titled Rear Connector CPU Card A port card rear panel holds the sixteen RJ 45 connectors associated with its corresponding front panel port card Intercom panels and interfaces connect to the matrix through this rear connector panel A fiber card provides two ports to connect fiber network cables An E Que card provides eight RJ 45 ports for connection to wireless equipment and three RJ 45 ports for DECT sync and LAN connections A blank panel covers an unused slot in the matrix ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 15 You can precisely locate CONNECTING THE CPU CARD a port with its column P The rear connector panel associated with the CPU card holds seven connectors as illustrated in
39. d s status lights and controls which are illustrated in Figure 2 2 D Reset Button Pressing the reset button causes the CPU card to stop its current activity and to restart The same configuration that was active before you reset the system will be active after you reset it During the reset configuration information reloads to the card s operational memory from its non volatile memory and the card starts running again from the beginning Note The reset button is slightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button Power Supply Lights 5 Volt Light When lit the 5V light indicates that the matrix s 5 volt power supply is actively supplying power to the CPU card 3 3 Volt Light When lit the 3 3V light indicates that the matrix s 3 3 volt power supply is actively supplying power to the CPU card Dot Matrix Lights The rectangular array of lights just below the power supply lights displays a number either 1 2 3 or 4 to indicate the currently selected configuration The Eclipse Configuration System ECS controls these lights ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 3 2 4 1 RESET BUTTON POWER SUPPLY LIGHTS When lit 5 volt power supply is on When lit 3 3 volt power supply is on 3 DOT MATRIX LIGHTS Displays the number of the currently selected software configurati
40. ded warranty at the time of purchase or at any time during the first two years of ownership of the product The purchase of an extended warranty extends to five years the warranty of any product offered with a standard two year warranty The total warranty period will not extend beyond five years WARRANTY WARRANTY Note VGC does not offer warranty extensions on UHF wireless intercom systems or on any product with a 1 year or 90 day warranty LIABILITY THE FOREGOING WARRANTY IS VGC S SOLE AND EXCLUSIVE WARRANTY THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY OTHER REQUIRED IMPLIED WARRANTY SHALL EXPIRE AT THE END OF THE WARRANTY PERIOD THERE ARE NO OTHER WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES FOR CONSUMABLES AND OTHER SUPPLIES OF ANY NATURE WHATSOEVER WHETHER ARISING IN CONTRACT TORT NEGLIGENCE OF ANY DEGREE STRICT LIABILITY OR OTHERWISE WITH RESPECT TO THE PRODUCTS OR ANY PART THEREOF DELIVERED HEREUNDER OR FOR ANY DAMAGES AND OR LOSSES INCLUDING LOSS OF USE REVENUE AND OR PROFITS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR THE LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU IN ANY EVENT TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW VGC S LIABILITY TO CUSTOMER HEREUNDER SHALL NOT UNDER ANY CIRCUMSTANCES EXCEED THE COST OF REPAIRING OR REPLACING ANY PART S FOUND TO
41. ed Connection to Eclipse Omega GPI Connector ECLIPSE OMEGA INSTRUCTION MANUAL To cause an input to detect an active signal you must send current from the relevant input pin The external device should draw no current to cause an inactive input and at least 5 mA to cause an active input The opto isolator drive line contains a 1 5 kOhm resistor to limit the current through the opto isolator You can therefore connect the input pins directly to a ground pin to cause an active input The voltage level at the external input pin should not be allowed to go below ground or above 6 V with respect to ground Pin Assignments for General Purpose Inputs Connector DB 25 Female Connector Logic Input1 Logic Input 2 Logic Input 3 Logic Input 4 Logic Input 5 Logic Input 6 Logic Input 7 Logic Input 8 V IN V IN V IN V IN PIN DESCRIPTION 1 Logic Input 1 2 Logic Input 3 3 Logic Input 5 4 Logic Input 7 5 N A 6 N A 7 N A 8 N A 9 Ground 10 Ground 11 Ground 12 Ground 13 Ground 14 Logic Input 2 15 Logic Input 4 16 Logic Input 6 17 Logic Input 8 18 N A 19 N A 20 N A 21 N A 22 Voltage In 23 Voltage In 24 Voltage In 25 Voltage In Figure 5 12 Pin Assignments for Eclipse Omega General Purpose Inputs Connector ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 15 LOCAL AREA NETWORK CONNECTORS LANI AND LAN2 The L
42. el Each MVX connector panel holds 16 RJ 45 connectors Clear Com ships each matrix with the required number of rear connector panels already installed Blank rear panels fill unused card slots INSTALLING REAR RJj 45 CONNECTOR PANELS IN THE FIELD Installing or removing a rear panel from the matrix is a simple procedure allowing you to easily customize the matrix to your operating environment To add a rear panel to the matrix ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 3 5 4 1 Remove the desired blank rear panel by loosening the screws and pulling the panel out The screws are attached and cannot be removed 2 Install the new rear panel by sliding the card into the card s guides at the top and bottom of the Eclipse Omega chassis 3 Tighten all of the screws on the rear panel To remove a rear panel from the matrix 1 Detach any devices connected to the rear panel s connectors 2 Loosen the screws that hold the rear panel to the matrix The screws are attached and will not fall off 3 Remove the rear panel by pulling the panel out INSTALLING CPU CARDS The CPU card s components include CMOS chips which are sensitive to static electricity Before touching the CPU card with your hands touch a grounded metal object such as any unpainted surface on the matrix to dissipate static electricity While handling the CPU card be careful not to bend any of the card s connector pins or component leads Before operating
43. ellCom antenna splitters Each E Que card set consists of a front card with a reset button and various status indicators and a rear card with eleven RJ45 ports giving eight standard ports DECT sync in and out and a LAN port for diagnostic use Each E Que front card has status LEDs for power port activity and LAN status The port activity LEDs indicate whether there is a device connected to an El port and that a connection has been established between this port and the connected device The E Que cards must be fitted in the rightmost available slots furthest away from the CPU cards on the Omega and up to four E Que cards can be fitted on a matrix POWER SUPPLIES Eclipse Omega matrix has two Euro Cassette power supply units that you can easily install or remove as needed One power supply unit can power an entire matrix the second unit provides a backup in case of failure or damage to the first unit In addition the two supplies have separate IEC connectors to AC mains and are designed for completely automatic and transparent changeover between supplies in the event of a power outage in one of the AC mains circuits An over temperature sensor is connected to both an audible failure alarm and a warning light allowing you to diagnose and correct any power anomalies while the system remains operational MVX REAR PANEL CONNECTORS PORTS The matrix s rear panel RJ 45 connectors are called ports You connect shielded categor
44. en the port card fails to communicate with the CPU card WIRING AUDIO DEVICES TO THE MATRIX The instruction manual Jnstalling the Eclipse Matrix System An Overview gives complete details about wiring audio devices to the matrix The Overview manual also discusses RJ 45 cables and other types of cable required for system installation The Eclipse Omega system features two IEC mains AC power connectors that provide separate power inputs for redundant power supply combinations If you ECLIPSE OMEGA INSTRUCTION MANUAL connect each AC input to a different mains AC branch one power supply will continue to operate if the other supplys mains AC branch opens WIRING PANELS TO THE MATRIX Eclipse uses a 4 pair analog or single pair digital wiring scheme between the matrix and panels All Eclipse panels have built in RJ 45 connectors 4 Pair Analog Four pair analog wiring is done with shielded CAT5 RJ 45 cable Matrix Frame R 45 Pin Numbers Pair 1 transmits analog audio from the matrix to the panel Pair 2 transmits digital data from the panel back to the matrix Pair 3 transmits audio from the panel to the matrix Pair 4 transmits digital data from the matrix back to the panel RJ 45 CONNECTOR AT MATRIX PORT RJ 45 CONNECTOR ON STATION OR INTERFACE 8165431 81654371 Views from front of connectors Shielded category 5 cables wired pin to pin Station RJ 45 Pin Numbers 85422 Input u 852 Output into Matrix 000
45. entifies a source destination or control function accessed by your intercom station Labels appear in the displays of the intercom station Labels can identify stations ports interfaced to other external equipment fixed groups party lines and special control functions Non volatile memory Data stored in the CPU s firmware ROM that is not lost when the power is turned off Panel Also referred to as station Any intelligent intercom device connected to the rear panel ports of the central matrix This term does not refer to devices connected through interfaces Port Any of the Eclipse matrix s 208 input output RJ 45 connectors that are used to connect cable from the matrix to stations and interfaces Each port connects to a separate audio channel in the matrix intercom system Program Any separate audio source that is fed into the intercom channels In television applications for example program audio is the audio that is broadcast on air Station Also referred to as panel Any intelligent intercom device connected to the rear panel ports of the central matrix This term does not refer to devices connected through interfaces Rack Unit or RU Standardized unit of mounting space on a rack panel Each rack unit is 1 75 inches 44 45 mm of vertical mounting space Therefore 1 RU is 1 75 inches 44 45 mm of vertical mounting space 2 RU is 3 5 inches 88 9 mm 3 RU is 5 25 inches 133 35 mm and so on Sid
46. er allowing you to instantly reconfigure your system as often as you require The CPU card itself will store up to four complete configurations in its operational memory that you can apply either directly from the CPU card or from the connected computer SETTING THE DEFAULT IP ADDRESS The CPU card LAN ports can be reset to their default IP addresses by pressing and holding the ENG and FULL RESET buttons on the CPU front card and then pressing the RESET button at the top and then holding the ENG and FULL RESET buttons until the card resets This will reset the LANI ethernet port to the factory default address of 172 16 2 100 and all other ethernet ports to the 0 0 0 0 blank address ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL FAIL SAFE OPERATION The CPU card s non volatile memory stores all information about the current operating configuration and the three additional configurations allowing the system to restore itself automatically after a power failure after replacement of a port card or after replacement of a panel An Eclipse Omega system will operate with either one or two CPU cards When you install a second card that card stores the four configurations in its RAM as a backup to the main card If the main card is removed or becomes non operational for any reason the system will automatically switch to the second card as backup CPU CARD LIGHTS AND CONTROLS The following sections describe the CPU car
47. etone The sound of your own voice heard in your own earphone as you speak Source In this manual the term source refers to a device such as an intercom station interface or beltpack that sends audio into the matrix The device to which audio is sent is called a destination VOX In the Eclipse Omega system when audio at a station exceeds a threshold a light switches on at the station s port card to visually cue you The threshold level is set in the Eclipse Configuration Software ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Return Material Authorization RMA numbers are required for all returns Both warranty and non warranty repairs are available WARRANTY LIMITED WARRANTY Vitec Group Communications VGC warrants that at the time of purchase the equipment supplied complies with any specification in the order confirmation when used under normal conditions and is free from defects in workmanship and materials during the warranty period During the warranty period VGC or any service company authorized by VGC will in a commercially reasonable time remedy defects in materials design and workmanship free of charge by repairing or should VGC in its discretion deem it necessary replacing the product in accordance with this limited warranty In no event will VGC be responsible for incidental consequential or special loss or damage however caused WARRANTY PERIOD The product may consist of several parts
48. figuration information is downloaded to the port cards and connected audio devices from the CPU card s microprocessor The same system configuration that was active before you reset the card will be active after you reset it You must press the button for more than two seconds for the reset to take effect ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Note Under normal operating conditions it is not necessary to perform a full reset Technical personnel might perform a full restart if they believe that the CPU card is operating incorrectly as a result of corruption of the microproccessors internal data or instruction sequence Specific Troubleshooting Examples The following examples describe specific problems and suggested solutions Problem A port light on a port card does not illuminate although there is a panel attached to that port 1 Check the panel and the wiring leading to it 2 Check the Frame Data light If there is no indication of matrix communication to this card while the other cards in the matrix are communicating reset the card 3 Replace the card 4 Replace the panel Problem Audio sounds low or distorted from a panel 1 Check the matrix s currently active CPU card s power lights If any of the lights are not lit replace the card 2 Check the port card s input and output gain settings in the program software 3 Check the panel s listen level adjustment settings in the program software SYSTEM BLOC
49. ftware ECS will report any failures in the fiber connection system ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 1 3 8 Loss of a Single Node If a node is lost on the ring the nodes adjacent to the failed node will loop back their connections to the failed node healing the ring using the working remains of the ring The configuration software ECS will report the failure This applies to the situation where the fiber card itself has failed rather than the matrix Loss of Two Fiber Connections If two adjacent fiber connections are lost on the ring this will be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed node healing the ring The configuration software will report the failure correctly as two failed cables If two non adjacent fiber connections are lost on the ring the nodes adjacent to the failures will loop back their connections to the failed cables healing the ring into 2 separate smaller rings The configuration software will report the failure Note that in this instance the two sub rings will be dependent on their Ethernet connections for configuration and data transmission but there will be no audio path between them Loss of Two Nodes If two adjacent nodes are lost on the ring this will be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed nodes healing the r
50. ga Matrix s Double Pole Double Throw Alarm Relay 4 GENERAL PURPOSE OUTPUTS CONNECTOR GP OUT The DB 25 connector labeled GP OUT connects the matrix to eight double pole double throw DPDT relays with contact ratings of 30 VDC at 1A Each general purpose output has a relay inside the Eclipse Omega matrix When a general purpose output is inactive the associated common pin on the GP OUT connector will be shorted to the relevant normally closed pin When a general purpose output becomes active the short between the common pin is broken and a new connection is made between the common pin and the normally open pin ECLIPSE OMEGA INSTRUCTION MANUAL DB 25 Male Connector PIN DESCRIPTION 1 RELAY I Common 2 RELAY I Normally Closed 3 RELAY Normally Open 4 RELAY 2 Common 5 RELAY 2 Normally Closed 6 RELAY 2 Normally Open 1 RELAY 3 Common 8 RELAY 3 Normally Closed 9 RELAY 3 Normally Open 10 RELAY 4 Common 11 RELAY 4 Normally Closed 12 RELAY 4 Normally Open 13 GROUND 14 RELAY 5 Common 15 RELAY 5 Normally Closed 16 RELAY 5 Normally Open 17 RELAY 6 Common 18 RELAY 6 Normally Closed 19 RELAY 6 Normally Open 20 RELAY 7 Common 21 RELAY 7 Normally Open 22 RELAY 7 Normally Closed 23 RELAY 8 Common 24 RELAY 8 Normally Closed 25 RELAY 8 Normally Open RELAY I RELAY 2 R
51. ganization of network components IFB Interruptible Foldback The term foldback refers to sending program audio or some other audio mix back to the announcer while he is on the air Doing so allows the announcer to monitor himself other announcers videotapes of commercials or some mix of sources while he is on the air This is typically found in television news and live broadcast events The announcer typically wears a small ear piece so he can hear the selected foldback audio mix When a director wants to give directions to the announcer on air or to announce changes in the program he must interrupt the foldback To do this he uses a channel specifically set up to interrupt the foldback audio Interface A piece of electronic hardware designed to convert the 4 wire signals of a central matrix port to some other form of communication such as 2 wire ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 8 1 party line telephone etc The interface is connected to a central matrix port The external non 4 wire device is then connected to the interface ISO The ISO function short for station ISOlation allows you to call a destination and interrupt all of that destination s other audio paths and establish a private conversation When you complete your call the destination s audio pathways are restored to their original state before the interruption Label A label is an alphanumeric name of up to five characters that id
52. gh a standard Ethernet connection The green LED indicates the port is connected and the amber LED indicates activity If you use this port you must add a ferrite to the socket end of each cable A suitable ferrite is Wiirth Electronik part 74271132 CONNECTING PORT CARDS Each rear connector panel associated with an MVX 16 port card holds the sixteen RJ 45 connectors that connect the matrix to intercom panels and interfaces Each front installed MVX A16 port card requires a corresponding rear connector panel Blank panels cover unused slots You can locate and identify each port on the matrix by using the rear panel numbering grid Columns 1 through 15 identify cards Rows 1 through 16 identify ports on each card Processor cards are designated P1 and P2 You can identify a port precisely by identifying its card number and port number on the card For exaample the ports on the first card are designated 1 1 1 2 1 3 1 4 and so on the ports on the second card are designated 2 1 2 2 2 3 2 4 and so on Each rear connector panel associated with a fiber card hold two fiber connection ports Each front installed E FIB card requires a corresponding rear connector panel Each rear connector panelassociated with an E Que card hold eleven RJ 45 ports Eight ports for connection to wireless equipment Two ports for DECT sync One port for LAN interface ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL ECLIPSE FIBER CARD LINKI
53. h bee Aso ea bbb Ge se ed 2 18 ECLIPSE FIBER CARD LINKING 1 ee ee eee eee eee 3 1 Fiber Card Description 1 23 4 aad acs BE se ped a Rat Weg 3 1 E FIB FIBER Card Front Panel Lights and Controls 3 1 Reset Button ci iter EE rU RE ORE grates 3 1 Power Supply amp Status Lights Coy ec d ies SEE es reddo 3 1 Primary Link Status LEDS oos tad cas ete enieee a 3 4 Secondary Link Status LEDs 4 esa sewed ee eed Sees Pel ER US 3 4 Status LED Leer ore ads eR caren eee Seite eter eire 3 4 Erame Data LED io tetas vete RR ERE PARA ET 3 5 FIBER Card REAR PANEL Lights and CONNECTIONS 3 5 Eye Safety io eed e tee aec OG apc Doce Reb dao nk nd bie ah 3 6 Configuring A Fiber Optic ConnecHOon 2 sees eese 3 6 Simplex Fiber Cabling ete tette E a acepte 3 6 Single Card Set Redundancy aioe oe VE er e RE AER E 3 6 Loss of Single Fiber Connection er deua vai eek eut 3 7 Lossofa Single Node Fri ens ab ss DEER BE ER ERAS DEER N pe 3 8 Loss of Two Fiber ConnectOnS ese cece eee eee eee 3 8 Loss af Two Nodes ordner XR ERR UM ER eee Wee eae 3 8 Dual Card Set Redundancy EE Some Ee ES DE Ed rer 3 8 Loss of Single Fiber Connection us ak n d aie e saca dete Bae 3 8 Lossora Single Node Sh Pasnew SL dnte de e tan d ID Me dU EA c diti 3 9 Loss of Two Fiber Connections vi SEE es EER ee DRE AER 3 9 Loss oF Two NOdES ns vu paa euo d esci e VeRO ER e MER 3 10 Fiber Optic Linking Card Failure 22 sein ht o dri hh 3 11 Faulf Tolera
54. h the ECS configuration software Each of the port card s 16 green VOX lights corresponds to one of 16 rear panel connectors or ports to which audio devices intercom panels or interfaces can be connected Frame Data Light The green frame data light illuminates to indicate successful communication between the port card and the CPU card 6 Status Light The red status light illuminates to indicate a failure in communication between the port card and the CPU card ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 9 POWER SUPPLY DESCRIPTION Eclipse Omega has two Euro Cassette power supply units that you can easily install or remove as needed One power supply unit can power an entire matrix the second unit provides a backup in case of an equipment failure In addition the two supplies have separate IEC connectors to AC mains power and are designed for completely automatic and transparent changeover between supplies in the event of an outage on one of the AC mains circuits For this feature to work each power supply should be connected to a different AC mains branch If the temperature inside the Eclipse matrix exceeds a threshold both an audible alarm and a warning light switch on allowing you to diagnose and correct power anomalies while the system remains in operation Each cassette has two status lights located on the power supply unit in the upper left corner The green light stays on continuously to let you kn
55. he pins and place it over pins 1 and 2 This is the ON position The Eclipse Omega matrix The battery is now powered installs in a standard Electronic Industry 3 DETAIL OF CON9 Association 9 inch 48 cm equipment rack D CPU CARD iz i i i i i iB l i 3 B Figure 5 1 CPU card with detail of CON jumper plugs ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 1 5 2 Before performing any service on the CPU card you must disconnect the card s battery To do so place the CON9 jumpers in the OFF position as described in the previous procedure PIN STATUS 1 On 2 Common 3 Off Table 5 1 CON9 Pin Configuration If you are going to store the matrix for more than 3 months or if you regularly turn off the power to the matrix you need to temporarily deactivate the CPU backup battery while the matrix is stored To do so put the CON9 jumper in the OFF position as described above When you wish to power up and start operating the matrix reconnect the CPU backup battery by placing the CON9 jumper in the ON position as described above CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type Lithium batteries can overheat or explode if they are shorted When you handle the CPU card or a loose battery DO NOT touch any external electrical conductors to the batterys terminals or to the circuits that the terminals are connected to Whenever you
56. he signal chain producing superior broadcast audio quality The system maintains 24 bit sampling and 30 Hz to 22 kHz frequency response Asix rack unit matrix housing up to 240 RJ 45 ports and dual redundant power supplies Fifteen available port cards supporting 16 ports each Fail safe redundancy achieved by two processor cards and two power supplies Power supplies that automatically switch to the correct voltage for compatibility around the world Eight general purpose inputs and eight relays located directly on the matrix Full compatibility with selected Matrix Plus 3 panels and interfaces selected 4000 Series II panels V Series panels and FreeSpeak CellCom antennas and splitters Matrices that link across cities nations or continents through trunk lines and fiber Uses the same fiber networking cards as the Eclipse Median matrix Connection to FreeSpeak CellCom antennas and splitters using the E Que card Multiple E Que cards can be fitted to a single matrix VOX programmable audio which visually cues you at the matrix when audio transmits at a programmed threshold on a connected intercom panel or interface ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL l l Virtual operation in which a complete networked system can be operated and maintained from anywhere in the world The system provides both local area network and Internet access to the central matrix Visual and intuitive Eclipse Co
57. iber Redundancy In all fault cases involving cable faults or loss of nodes on the ring the remaining nodes may experience audio breaks or disturbances and loss of crosspoint information or data When a ring with non adjacent failures sub divides into two sub rings audio and data from the failed nodes will not be available to the nodes in either sub ring audio and data will continue to be ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 1 available to nodes within the same sub ring but data may still be available to all nodes that are still functioning if there is an intact independent Ethernet connection to those nodes If a Matrix frame connected as a node of the fiber optic link is reset powered down or failed this will constitute a lost or failed node on the ring and this node will experience audio breaks or disturbances and loss of crosspoint information or data for up to 5 seconds after the fault condition is cleared or repaired ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL ECLIPSE E QUE CARD E QUE CARD DESCRIPTION The E QUE card allows the Eclipse matrix connectivity to FreeSpeak CellCom antennas and FreeSpeak CellCom antenna splitters The connection options supported are 8 x FreeSpeak CellCom antenna direct connections 2 x FreeSpeak CellCom splitter connections up to 5 antennas each Up to 40 antennas and 200 beltpacks can be connected to a matrix using E Que cards Each E Que card set consists of a front card with a rese
58. iber connections are lost on the ring this will be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed node healing the ring The configuration software will report the failure correctly as two failed cables If two non adjacent fiber connections are lost on the ring the nodes adjacent to the failures will loop back their connections to the failed cables healing the ring into 2 separate smaller rings The configuration software will report the failure Note that in this instance the two sub rings will be dependent on their Ethernet connections for configuration and data transmission but there will be no audio path between them Switching to the secondary ring will cause audio breaks or disturbances and temporary loss of crosspoint data The self healing mechanism is performed autonomously by the fiber Linking Card whereas the switch over between redundant cards and rings requires software or operator intervention If two adjacent fiber connections are lost on one ring and the other ring has a similar failure this will be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed node healing the ring The configuration software will report the failure correctly as two failed cables If two non adjacent fiber connections are lost on one ring and the other ring has a similar fault the nodes adjacent t
59. ices to momentarily stop their current activity and to restart The card s frame data light goes off when the reset starts and comes back on when the reset is complete During the reset configuration information downloads to the card and its connected audio devices from the CPU card If the entire system is operating except for one port card or one or more panels connected to the card press the reset button for that card only Note The reset button is slightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button 2 Power Supply Lights 12 Volt and 12 Volt Power Supply Lights The matrix s 12 volt and 12 volt power supplies provide electric current to these two green lights When lit these lights indicate that the matrix s 12 volt and 12 volt power supplies are present and supplying electric current to the card 5 Volt Power Supply Light The matrix s 5 volt power supply provides electric current to this green light When lit the light indicates that the 5 supply is present and supplying electric current to the card ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 1 2 8 3 3 Volt Power Supply Light The matrix s 3 3 volt power supply provides electric current to this green light When lit the light indicates that the 3 3 volt supply is present and supplying electric current to the card 1 RESET BUTTON PO
60. ing The configuration software will report the failure correctly as two failed nodes If two non adjacent nodes are lost on the ring the nodes adjacent to the failures will loop back their connections to the failed nodes healing the ring into 2 separate smaller rings The configuration software will report the failure Note that in this instance the two sub rings will be dependent on their Ethernet connections for configuration and data transmission but there will be no audio path between them DUAL CARD SET REDUNDANCY This is shown as in Figure 3 4 with both Card set A and Card set B fitted in each node of the ring In this case each Matrix Frame contains two Fiber optic Linking card sets This approach affords full redundancy offering protection against component failure within a single Fiber optic Linking Card Set Again in the absence of an Uninterruptible Power Supply this configuration will not protect against loss of the node or Matrix Frame itself Loss of Single Fiber Connection Ifa single fiber connection is lost on one ring and the other ring is intact then the active ring always attempts to heal itself by reversing the direction of data flow to bypass the failed connection The self healing mechanism is performed autonomously by the fiber linking card If the extent of the failure is such that the active ring is unable to heal itself the the system will switch to the secondary ring Switching to the secondary ring will cause aud
61. ing as master If there is a backup CPU card in the matrix its master light will not illuminate if the primary card is acting as master LAN A Light When you connect a local area network LAN to the matrix s LAN A port the CPU card s LAN A LED lights to indicate a connection to the Eclipse Configuration System LAN A LAN B Light When you connect a second local area network to the matrix s LAN B port the CPU card s LAN B LED lights to indicate a connection to the Eclipse Configuration System ECS LAN B Sync Light When you connect multiple Eclipse matrices together the sync light illuminates to indicate that the matrices are connected and synchronized SI Light The SI light flashes to indicate communications activity 5 Configuration CONFIG Button The CPU card can hold four complete system configurations in its operational memory When you tap the CONFIG button the number of the currently active configuration either 1 2 3 or 4 appears in the dot matrix display Each time you subsequently tap the button the next configuration number in the series appears in the dot matrix display The numbers cycle forward until all of the choices have been displayed then start again at 1 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 5 When a non active configuration s number appears in the display it flashes to indicate its non active status When an active configuration s
62. ing carton 2 Leave atleast 2 inches 51 mm of clearance on all sides of the matrix chassis to ensure proper airflow Do not block ventilation vents 3 Check the position of circuit cards power supplies and rear connector panels Later sections in this chapter give more information on these items 4 Apply AC power to the unit The unit has two separate AC power entry connectors for the two separate power supplies in the system INSTALLING POWER SUPPLIES The Eclipse Omega systems DC power supplies run on AC mains power Two identical Euro Cassette power supplies are provided to ensure that every matrix will have redundant power that is to ensure that the matrix will continue to operate even if one supply output fails Each of the power supplies must be connected to a dedicated branch of AC mains power The matrix will continue to operate even if one of the AC power branches fails Clear Com ships each matrix with power supplies already installed When you receive the matrix connect the power supplies to AC mains power using the IEC power connectors on the matrix s rear panel A fully equipped Eclipse Omega matrix 13 port cards 2 expansion cards requires 100 to 240 VAC at 40 to 50 Hz with a maximum dissipation of 400 W INSTALLING THE REAR RJ 45 CONNECTOR PANELS The matrix s rear panel is constructed of modular individually installable connector panels Each port or expansion card has a corresponding rear connector pan
63. io breaks or disturbances and temporary loss of crosspoint data ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL The self healing mechanism is performed automatically by the fiber linking card whereas the switch over between redundant cards and rings requires software or operator intervention Loss of a Single Node If a node is lost on one ring due to a single fiber optic linking card set failure and the fiber optic linking card set for the other ring is healthy and the other ring is intact then the active ring always attempts to heal itself The nodes adjacent to the failed node will loop back their connections to the failed node healing the ring using the working remains of the ring If the extent of the failure is such that the active ring is unable to heal itself the the system will switch to the secondary ring Switching to the secondary ring will cause audio breaks or disturbances and temporary loss of crosspoint data The self healing mechanism is performed autonomously by the fiber linking card whereas the switch over between redundant cards and rings requires software or operator intervention If a single node is lost on both rings due to multiple fiber optic linking card set failures etc the nodes adjacent to the failed node s will loop back their connections to the failed node s healing the rings and the most intact ring will be used The configuration software will report the failure Loss of Two Fiber Connections f two adjacent f
64. is manual system 5 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not place naked flame sources such as candles on or near the matrix 6 Do not defeat the safety purpose of the polarized plug or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 7 Protect power leads from being walked on or pinched particularly at plugs at convenience receptacles and at the point where they exit from the apparatus Note A convenience receptacle is an extra AC power outlet located on the back of a piece of equipment intended to allow you to power other equipment 8 Only use attachments accessories specified by the manufacturer 9 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 10 Unplug the apparatus during lightning storms or when unused for long periods of time 11 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such
65. is passing between the CPU card and this card Figure 3 1 Front Fiber Card ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 3 3 4 3 Primary Link Status LEDs These LEDs indicate the status and functioning of the primary A fiber optic link Link LED This LED indicates whether a link has been established on the primary fiber optic circuit transceiver A When illuminated a link is present TXVR LED This LED indicates when data is being transmitted on the primary circuit It is illuminated when data is present on the circuit ACT LED This LED is lit if the primary fiber optic circuit is active ERR LED This LED will be illuminated if an error condition is detected on the primary fiber optic circuit 4 Secondary Link Status LEDs These LEDs indicate the status and functioning of the secondary B fiber optic link Link LED This LED indicates whether a link has been established on the secondary fiber optic circuit transceiver A When illuminated a link is present TXVR LED This LED indicates when data is being transmitted on the secondary circuit It is illuminated when data is present on the circuit ACT LED This LED is lit if the secondary fiber optic circuit is active ERR LED This LED will be illuminated if an error condition is detected on the secondary fiber optic circuit Status LED The green frame data LED illuminates to indicate successful communication between the fiber master
66. length of the cable is approximately 10 feet 3 meters A computer has either a 9 pin serial port or a 25 pin serial port Figure 5 5 shows the wiring for a 9 pin port Figure 5 6 shows the wiring for a 25 pin port ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 9 Matrix Frai IBM PC RS 232 Computer Serial Port DB 9F DB 9M Cable Connector Cable Connector le Transmit TXD Na EE Ground GND Eclipse Frame EYE SM Cable i x able Computer Serial Port Rast Cable Connector onnector Figure 5 6 Wiring the Matrix DB 9M to a DB 25F Computer Serial Port Connector 3 ALARM 1 0 CONNECTOR The DB 9F connector labeled Alarm I O connects the matrix to a control circuit for an external alarm such as a light or bell The external alarm activates whenever an alarm condition is detected in the matrix 5 10 ECLIPSE OMEGA INSTRUCTION MANUAL NOTE If your computer does not have a serial port and only offers USB adapters are generally available from computer parts suppliers The following conditions trigger an alarm 1 If any of the voltages produced by the first power supply unit fall below their normal levels 2 If any of the voltages produced by the second power supply unit fall below their normal levels 3 If an external alarm circuit or other logic circuit connected to the power supply is activated 4 If either of the two power supply unit fans stop operating 5 If software on a ma
67. mption 300 W Maximum Temperature Humidity Maximum Matrix Performance Sample Rate Resolution Frequency Response 48 kHz sampling Crosstalk adjacent channel Nominal Level Matrix headroom Distortion Off Noise On Noise Key Response Intra System Linked Systems Fiber Interface Front Card Height Depth Temperature Humidity Power ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 0 to 50 C ambient 55 to 70 C storage 90 non condensing 48 kHz 24 bit 30 Hz 22 kHz 3 dBu 70 dBu 0 dBu 18 dBu 0 05 96 amp 0 dBu 300 Hz to 10 kHz 0 1 96 0 dBu 100 Hz to 20 kHz 100 dBu relative to 20 dBu 20 Hz 22kHz 85 dB relative to 20 dBu 20 Hz 22 kHz lt 40 ms for audio route 60 ms for audio between matrices 6RU 300 mm 0 to 40 C operating 55 to 70 C storage 40 90 non condensing 3 3V 1 2 Fiber Interface Rear Card Height Depth Temperature Humidity Power E Que Interface Front Card Height Depth Temperature Humidity Power combined cards E Que Interface Rear Card Height Depth Temperature Humidity Analog Port Card Height Depth Audio Interface Input Format Output Format Ground Isolation Port Card Outputs Level Impedance Frequency Response Distortion Port Card Inputs Level Impedance Frequency Response Distortion Data Interface 16 bi directional Input Format Output Format Input Termination Output Termination Isola
68. nce aiios vbi RA e RE RE DEER HE OER DE cba dod 3 11 Dual Card Set Redundant System Full Redundancy 3 11 Single Card Set Redundant System Fiber Redundancy 3 11 ECLIPSE EGUE CARD 2 res EE cee Pia eee pase es 4 1 EQUE Card Descriptions ian eant Seeds ately DE aa ae De ee 4 1 E QUE Card Front Panel Lights cant tah ke dee ehe uet etian 4 1 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Reset Button 0 ccc ae e e e s 4 1 Power Supply amp Status Lights ee Ee Ge De wa wk Te Dept eral 4 1 Status Lights iios EERS SEERDE ES PT FEE dA MEER Go REAR 4 4 LAN Data Light ii ss aisha Die SL tae Ld adu eei eo erie 4 4 FAN DELE fred Speco ae uet ca outs Lm ie N 4 4 E QUE Card REAR CoNNECTIONS ea eg ER ere ra 4 4 E Que Card Applications euasit fien ed ete te etos 4 6 FreeSpeak GellCom Application 15d eec drehte chet ee ira 4 6 INSTALLATION eoo mae RE en arte DO o toe orc 5 Reconnecting the CPU Card s Backup Battery 0 000000 00 5 1 Verifying the Shipment c accusest d aided estie d T otl ee whe Nak 5 2 Unpacking the System 2 Sala cosa o D Urs LO Ea rss rr rese ties 5 2 Installing the Eclipse Omega Matrix iu le 2504S FAG LA YS ATE 5 3 Installing Power Supplies mp oda E POLES p orc oa hee 5 3 Installing the Rear RJ 45 Connector Panels iS Se ES Se ee 5 3 Installing Rear RJ 45 Connector Panels in the Field 0 5 3 Installing CPU G rds an ooo fie Eg OE Lo o rate ular Ge ee 5 4 H
69. nd RLY 6 cards consult their respective manuals in the Eclipse Omega manual set RS 232 CONNECTOR The female 9 pin D type socket labeled RS 232 connects the CPU card to an external computer ALARM I O CONNECTOR The female 9 pin D type socket labeled Alarm I O connects the Eclipse matrix to an external alarm indicator such as a light or buzzer and or to an external alarm source 4 GENERAL PURPOSE OUTPUTS CONNECTOR GP OUT The male 25 pin D type socket labeled GP OUT connects the CPU card to eight general purpose outputs GPOs General purpose outputs are single pole double throw relays with contact ratings of 30 VDC volts direct current at 1 ampere A general purpose output or relay is a switch that you control remotely You program the relay in the ECS configuration program to close a contact whenever an intercom panel s key is pressed When the contact is closed it completes an electronic circuit s signal path so that a remote device such as a light is powered You can program a GPO to mute a speaker to turn on an applause light to turn on a door lock or to perform a variety of other functions For example to get the attention of a panel operator working in a high noise environment such as a control booth you can program a relay to switch on a light at his panel each time he receives an incoming call to ensure that he will not miss the call Note If you use the GP OUT port yo
70. nfiguration System ECS programming software THE ECLIPSE OMEGA MATRIX A complete Eclipse Omega system consists of a central matrix and the remote audio devices intercom panels interfaces 4 wire equipment connected to it Each element of the Eclipse Omega system is briefly described in this chapter and more fully described later in this manual and in the Eclipse set of manuals The Eclipse set of manuals includes individual manuals on each matrix panel and interface in the system as well as Installing the Eclipse System An Overview MATRIX ASSEMBLY As shown in Figure 1 the matrix assembly consists of the following components The metal housing for the circuit cards and power supplies called the matrix The removable and replaceable circuit cards The removable and replaceable power supplies The rear panel connectors which link the circuit cards to devices and media such as intercom panels interfaces wireless equipment and optical fiber mE Edipse Frame RJ 45 Connectors Ports on Back Panel fl ea 16 Port Circuit Cards J Two Expansion Card Dual Redundant Dual Redundant CPU Cards Power Supplies Figure 1 1 The Eclipse Omega Matrix Assembly Note The term central matrix is used to differentiate the system s core bardware and software from the connected intercom panels and interfaces The central matrix itself consists of the matrix hardware and the ECS software ECLIPSE OMEGA MATRI
71. ng CAT3 cable and it is recommended that shielded cable is used Note If an E Que card is fitted in the Omega with antennae or splitters connected and active inserting a second E Que card to the left of the first card seen from the front will cause a temporary loss of audio to beltpacks using the original E Que card usually for about 10 seconds The beltpacks do not go offline and signalisation is not lost ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 4 9 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL INSTALLATION RECONNECTING THE CPU CARD S BACKUP BATTERY MPORTANT Before you install the Omega you must reconnect the CPU backup battery The CPU card has a lithium backup battery that powers the CPU memory if the AC electricity fails This backup battery is shipped disconnected to preserve battery life When you receive the matrix you must reconnect the battery The matrix will operate if you do not reconnect the battery However if you power down the matrix you will lose all configuration information stored in the matrixs CPU card To reconnect the CPU memory s backup battery 1 Please observe anti static procedures The CPU card can be damaged by static electricity Please ground yourself and tools before touching cards 2 Locate CONO on the centermost upper portion of the CPU card Under the CONO heading there are three pins A jumper plug is placed over pins 2 and 3 This is the OFF position 3 Lift the jumper plug off t
72. nserting a CPU can reset the matrix It is advisable to replace CPUs in maintenance down times ECLIPSE OMEGA INSTRUCTION MANUAL VERIFYING THE CPU CARD INSTALLATION You can check the CPU card s operating status by looking at the lights on the front of the card The following lights indicate that the card has been properly installed in the matrix e The two power supply lights labeled 5V and 3 3V illuminate green steadily to indicate that the power supplies are present The dot matrix array of lights displays a number to indicate which of the four stored configurations in the card s memory is currently operating The OK light flashes to indicate that the CPU card software is running The master light illuminates steadily on the currently active CPU card indicating that the CPU card is properly installed and operating correctly INSTALLING PORT AND EXPANSION CARDS Before installing a port or expansion card the card s associated rear connector panel should be installed To install a port or expansion card 1 Carefully place the card in the appropriate slot Make sure the card is aligned with the top and bottom precision guides 2 Push the card toward the backplane connectors 3 When the card has almost reached the backplane connectors open the two ejector tabs allowing them to clear the edges of the matrix Gently insert the card further until it touches the backplane connector guides
73. nterfaces and communications cards allow communication with wireless equipment and fiber optic links Two Euro Cassette power supplies provide fail safe redundancy in the event of a component failure or an AC circuit outage Front panel lights give you information about the condition of the power supplies allowing you to take preventative corrective action Each MVX circuit card connects to an individual panel on the back of the Eclipse Omega matrix This panel holds the RJ 45 sockets for connecting cable to intercom panels and interfaces The Eclipse Omega matrix is completely modular allowing you to add or remove cards power supplies and connector panels to meet the operational needs of your environment FRONT PANEL CONTROLS AND LIGHTS mer le h Two Euro Cassette c o Power Supplies Clear Com Eclipse f i Power Supply Lights and Alarm Reset Button vor met ht nate s I p 7 Port Cards through 15 PI amp P2 Figure 2 1 Front Panel of Eclipse Omega Matrix ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 1 Note General Purpose Outputs are also referred to as relays Note If the configuration does not remain in memory after you power off please see the first section in Chapter 3 Reconnecting the CPU Card s Backup Battery 1 1 CENTRAL PROCESSOR UNIT CPU CARD DESCRIP TION The central processor unit CPU card holds the circuitry that allows the system t
74. number either 1 2 3 or 4 appears in the display it illuminates solidly without flashing to indicate that it is the active configuration To select one of the four configurations from the CPU card 1 Repeatedly press the CONFIG button until the desired configuration s number 1 2 3 or 4 appears in the display 2 When the desired number appears press and hold the CONFIG button until the display stops flashing This should take about three seconds The selected configuration then becomes the system s active operational configuration Engineering ENG Button This button is used to reset the system to the default IP addresses 7 Full Reset Button When you perform a full reset all cards in the matrix reset regardless of any system preferences in the program software and non volatile memory is cleared To perform a full reset 1 Press and hold the card s lower RESET button the full reset button 2 Simultaneously press and release the card s upper RESET button 3 Continue holding the card s lower RESET button for two seconds The card performs a full reset The same configuration that was active before you reset the system will be active after you reset it When the cards and connected audio devices reset they momentarily stop their current activity and restart During this process configuration information is downloaded to the cards and audio devices from the CPU card s non volatile RAM
75. o connect to and communicate with the following interfaces A computer External alarms Eight general purpose inputs GPIs Eight general purpose outputs GPOs Two separate local area network LAN connections for Ethernet based communication with a network An external interface that provides additional GPIs and GPOs In addition the card s operational memory holds four complete preassigned system configurations to access and activate either directly from the CPU card or from the ECS configuration software CREATING AND STORING SYSTEM CONFIGURATIONS A configuration is a complete set of operating parameters for the system which includes talk and listen paths for each connected intercom panel Depending on the interfaces installed the configuration can also include more sophisticated features such as paging call signaling interrupt foldback IFB ISO groups automatic DTMF dialing routing and many other features When you connect an external computer to the matrix you can retrieve the current configuration information stored in the CPU microprocessors memory using the Eclipse Configuration Software and display the configuration on the computer s screen You can then apply the current configuration modify it or create a new configuration with the Eclipse Configuration Software If you create more than one configuration you can store unused configurations on your computer s hard disk or on CD ROM to use lat
76. o the failures will loop back their connections to the failed cables healing the ring into 2 separate smaller rings The configuration software will report the failure ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 9 Note that in this instance the two sub rings will be dependent on their Ethernet connections for configuration and data transmission but there will be no audio path between them Txvr Txvr A B Patch Panels Txvr Txvr R T X X xa ax C FX FX Nl LP Ter A Tr a xx x X x V x d E D xD Ed Txvr T B A Txvr Txvr Figure 3 4 Ring Topology Dual Card Set Redundancy Loss of Two Nodes If two adjacent nodes are lost on the ring this will be handled as for the loss of a single node where the nodes adjacent to the failed node will loop back their connections to the failed nodes healing the ring The configuration software will report the failure correctly as two failed nodes If two non adjacent nodes are lost on the ring the nodes adjacent to the failures will loop back their connections to the failed nodes healing the ring into 2 separate smaller rings The configuration software will report the failure Note that in this instance the two sub rings will be dependent on their Ethernet connections for configuration and data
77. om the matrix Note that this feature only operates if there are two CPU cards installed in the matrix If there is only one CPU card the Temp alarm light does not switch on if the card is removed Fan Fail Alarm The red fan fail alarm light illuminates when either fan in the power supply module stops rotating correctly PSUI Fail When the first power supply unit is operating correctly the red PSUI light stays off while the four green power supply lights 12V 5V 3 3V 12V stay on continuously If a DC output or AC input to the first power supply drops too low the red PSUI light switches on to warn you The amber light on the power supply unit itself also switches on to indicate the same condition One of the green power supply lights may then switch off to help indicate the source of the trouble Note that the PSUI fail light only works if the first power supply is plugged into the matrix s midplane from inside the matrix Note A temperature sensor inside the power supply senses if the power supply overheats and switches on the second matrix cooling fan The red Temp light switches on to indicate that the active CPU card not a power supply has overheated PSU2 Fail When the second power supply unit is operating correctly the red PSU2 light is off while the four green power supply lights 12V 45V 3 3V 12V are on continuously When a DC output or AC input to the second power supply drops too l
78. on STATUS LIGHTS When flashing software is running Blinks when two CPU cards are exchanging information When lit this CPU card is acting as master card Blinks when LAN A is connected and running Blinks when LAN B is connected and running Blinks when multiple matrices are connected and synchronized Reserved for future use 5 CONFIGURATION CONFIG BUTTON 6 DEFAULT IP ADDRESS RESET BUTTON Press with full reset and reset to set default IP address 7 FULL RESET BUTTON When held through a reset cycle results in a full system reset When pressed with the ENG button and reset button sets the default IP address Figure 2 2 CPU Card s Front Panel Lights and Controls ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 4 Status Lights OK Light When flashing the OK light indicates that the CPU card is successfully communicating with the Eclipse Configuration System ECS IPC Interprocessor Communication Light The interprocessor communication IPC light only operates when there are two CPU cards in the matrix When lit the light indicates that the two CPU cards are exchanging information Master Light An Eclipse Omega system can have two CPU cards although the system will operate with only one If the primary card becomes unavailable for any reason the second card can serve as backup while the primary card is repaired or replaced The master light illuminates on whichever CPU card is currently serv
79. ort Connector 5 10 Wiring the Matrix DB 9M to a DB 25F Computer Serial Port Connector 5 10 Wiring the Alarm I O Connector to an Alarm Relay Connector 5 11 Eclipse Omega Matrix s Double Pole Double Throw Alarm Relay 5 12 Pin Configuration of the General Purpose Outputs Connector 5 13 Opto Isolated Connection to Eclipse Omega GPI Connector 5 14 Non Isolated Connection to Eclipse Omega GPI Connector 5 14 Pin Assignments for Eclipse Omega General Purpose Inputs Connector 5 15 Pin Assignments for LAN1 and LAN2 Connectors see 5 16 System Block DIABEam secerni triosi vsaatial shart weeds Po Es ee bisce Cites Pi sed ia 6 7 ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL IMPORTANT SAFETY INSTRUCTIONS Please read and follow these instructions before operating an Eclipse Omega matrix system Keep these instructions for future reference 1 WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 2 Do not use the apparatus near water 3 Clean only with a dry cloth Pease neadiand follow these 4 Do not block any ventilation openings Install in accordance with the instructions before operating manufacturers instructions Install the Eclipse Omega matrix system according an Eclipse Omega matrix to the directions in the Installation Chapter of th
80. ot Patching o oae uns ux vk eal hee te ween he exe SUR e p i 5 4 Verifying the CPU Card Installation 2 hence tee Rd 5 5 Installing Port and Expansion Cards ied d oan d e ERIGI Yt RAE 5 5 Static Sensitivity N s 5 5 F t Patehingfe se ds Scales aas e Eq C ENTE TAE M DER ded a 5 5 Slot Numbering GEENEEN Po Danae tra rr od 5 6 Coifieutatiali cgo TA pep Ee berg AO OPER bud Ra Oed AT 5 6 Verifying Port Card Installatlor u yr ciate ay Fette b Vn rene e Dea d 5 6 Wiring Audio Devices to th Matrix coo eee Oe VES 5 6 Wiring Panels to the Matrix oss oae Pe ecco dee bro eb sees 5 7 4 Pair Analogie teca 2 disc ed sb r ren ioni E ert HUE etel Ee mol CLE dob 5 7 Single Pair Digital ado eeu ona Vo ste eg Le piter 5 8 Wiring CPU Card Interfaces st ae EE Lees Cons ie ad pe 5 8 GPI RLY Interface Connectors x ila ates Ver epe rd at ds 5 9 RS 232 DB 9 Connector ses EE SE SS Se Ee se se se 5 9 Alarm dO Connecter Ls rece PER bed ian Sheed oe bere kane tee es 5 10 General Purpose Outputs Connector GP OUT iese see se 5 12 General Purpose Inputs Connector GP IN 0 0 0 0 0 rss rerna 5 13 Local Area Network Connectors LAN1 and LAN2 5 16 MAINTENANCE ias rtr matic ava ti Ran eto a C t n n eer dote 6 Introduction 5 sube eR V DR E S 6 1 Routine Maintenance Recommendations ssseeerrerrrrererrrr rs 6 1 Maintaining the Matiz i SR Des de soe bedde dares bota deis 6 1 Recommended Spare Parts ord aus aes ER ER DE op enw sage
81. ow the red PSU2 light switches on to warn you The amber light on the power supply unit itself also switches on to indicate the same condition One of the green power supply lights may then switch off to help indicate the source of the trouble Note that the PSU2 fail light only works if the second power supply is plugged into the matrix s midplane from inside the matrix Note A temperature sensor inside the power supply senses if the power supply overheats and switches on the second matrix cooling fan The red Temp light switches on to indicate that the active CPU card not a power supply has overheated ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 13 Fan On Indicator Two fans deliver forced air cooling to the matrix s power supplies The primary fan runs continuously If a temperature exceeding a threshold is detected in a power supply and extra cooling is required a second fan switches on to increase the air flow The fan on alarm light illuminates red to indicate that the second fan is on POWER SUPPLY LIGHTS The green power supply lights illuminate to indicate that the power supplies are receiving 12 V 12 V 5 V and 3 3 V power ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL CONNECTING THE MATRIX The Eclipse Omega matrix connects to devices such as the configuration computer panels interfaces and other matrices through its rear panel hardware connectors often called ports These connectors are house
82. ow that the unit is receiving appropriate power The amber light goes on when a DC output or AC input falls too low DIAGNOSING POWER SUPPLY PROBLEMS Figure 2 4 illustrates the front panel alarm lights power supply lights and reset button An alarm source triggers the main alarm light and also one of the additional six red alarm lights allowing you to identify or correct alarm conditions before they affect the operation of the matrix Each of the four green power supply lights stays on continuously to show that the power supplies are receiving sufficient AC current When one of these lights switches off the power supplies need to be replaced or repaired Under normal operating conditions the red front panel alarm lights stay off while the green power supply lights stay on continuously The power supplies may need to be adjusted if E Que or fiber cards are installed For details of the adjustments please refer to the system upgrade manual ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Euro Cassette Euro Cassette Power Supply I Power Supply 2 Euro Cassette Alarm Lights Alarm Lights Power Supply Lights Main Alarm Light 12 Volt Light External Alarm EXT ALARM Light RN 5 Volt Light Temp Alarm Light ilk 3 3 Volt Light Fan Fail Alarm Light 12 Volt Light PSUI Fail Light PSU2 Fail Light Fan On Alarm Light Clear Pam Eclipse Alarm Reset Button Figure 2 4 Power supply module s front door CONDITIONS THAT CAUSE AN ALARM
83. pair of the system with minimum downtime Clear Com recommends keeping the following spare system components in good working condition at all times One CPU card One port card One Euro Cassette power supply module One of each type of intercom panel in the system One of each type of interface in the system FAIL SAFE MODES High reliability is one of the main objectives of the Eclipse Omega system design The following features of the system minimize the effects of a component failure ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 6 1 6 2 DUAL INDEPENDENT POWER SUPPLIES The Eclipse Omega matrix includes two Euro Cassette power supply units One power supply unit can power an entire matrix the second unit provides a backup in case of an equipment failure In addition the two supplies have separate IEC connectors to AC mains power and are designed for completely automatic and transparent changeover between supplies in the event of a power failure on one of the AC branches CAUTION To reduce the risk of electric shock plug each of the power cords to separate branch circuits with different service ground POWER SUPPLY ALARM OUTPUT The power supplies contain an over temperature sensor that is connected to both an audible alarm and a warning light giving you the necessary forewarning to diagnose and correct any power anomalies while the system remains operational If any individual power supply fails an alarm can be is
84. perating except for one fiber card press the reset button for that card only NOTE The reset button is slightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button Q Power Supply amp Status Lights 3 3 Volt Power Supply LED The matrix s 3 3 volt power supply provides electric current to this green light When lit the light indicates that the 3 3 volt supply is present and supplying electric current to the card Processor LED When lit the LED indicates that the fiber card on board processor is running ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 1 3 2 Front Card LED When lit indicates that the front card in functioning normally Rear Card LED When lit indicates that the rear card is functioning normally ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 1 RESET BUTTON Q POWER SUPPLY amp STATUS LIGHTS When lit 3 3 V power supply is on When lit the processor is running When lit the front card is functioning When lit the rear card is functioning G LINK A STATUS LIGHTS Link active When lit the link is established Indicates link Indicates data transmit error LINK B STATUS LIGHTS Link active When lit the link is established Indicates link Indicates data transmit err 5 STATUS LIGHT When flashing this light indicates card status FRAME DATA LIGHT 6 When flashing this light indicates that information
85. port card Before repairing or replacing card try to determine where the problem is occurring You can try one or both of the following options OPTION 1 Take the bad card out of the matrix and insert it into a known good slot in the matrix If the power supply lights still do not illuminate the problem is probably in the card itself Repair or replace the card If the power supply lights illuminate the problem may be in the matrix s backplane connectors which carry electric current from the power supplies to the cards You can send the matrix to Clear Com for investigation or repair In the meantime you can substitute another matrix for the damaged one Clear Com will send you a matrix to use while the damaged one is being repaired OPTION 2 Take a known good card and insert it into the bad slot If the power supply lights illuminate the problem is probably in the card Repair or replace the card If the power supply lights do not illuminate the problem may be in the matrix s backplane connectors which carry electric current from the power supplies to the cards You can send the matrix to Clear Com for investigation or repair In the meantime you can substitute another matrix for the damaged one Clear Com will send you a matrix to use while the damaged one is being repaired Once you have isolated the problem to the card or the backplane it is easier to take the next step which is to repair or replace the suspec
86. r optic Linking card set This is shown as in Figure 3 3 This approach still affords fiber connection redundancy since each rear card houses two fiber optic transceivers In the absence of an Uninterruptible Power Supply this configuration will not protect against loss of the node or Matrix Frame itself ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Patch Panels Figure 3 3 Ring Topology Single Card Set Redundancy Loss of Single Fiber Connection Ifa single fiber connection is lost on one ring and the other ring is intact then the active ring always attempts to heal itself by reversing the direction of data flow to bypass the failed connection If the extent of the failure is such that the active ring is unable to heal itself then the system will switch to the secondary ring The self healing mechanism is performed automatically by the Fiber Linking Card whereas the switch over between redundant cards and rings requires software or operator intervention Switching to the secondary ring will cause audio breaks or disturbances and temporary loss of crosspoint data If a single fiber connection is lost on both rings the nodes adjacent to the failures will loop back their connections to the failed cables healing the rings and the most intact ring will be used The Eclipse Configuration So
87. rcom Panels and Accessory Panels 02 cee eee eee eee 1 5 ie ee ASE ME UEBER OPE male Meee Ae Rc P EROR EO BEA od 1 5 OPERATION SA ie Ge xu sad dte NA S Desde s 2 The Eclipse Omega Matrix and Circuit Cards 1 0 0 0 eeu 2 1 Front Panel Controls and Lights 2t eere d rado E eus 2 1 Central Processor Unit CPU Card Description llle ee 2 2 Creating and Storing System Configurations ssseesersrrrers 2 2 Setting the Default TP Address AE Re le eu aan e rot erc aes 2 2 Fail Safe Operation ascia bee cae whee Ropa a Sch CR RUE qa 2 3 CPU Card Lights and Controls a ias ad ces BE eee ea 2 3 Reset Button ceu A RIDERS I UE ere ie GE tS tete 2 3 Power Supply Lights qu EEN eb insane coe e pede KEN oe ie a b 2 3 Dot Matrix Lights so Ed es ty oe tee anu bee ER e Et 2 3 Status Lights i slant ue ire OE eue eol REI IN idee Ted aed 2 5 Configuration CONFIG Button i ees Vs ER DERE ebbe 2 5 Engineering ENG Button washes ae toe ct eed EP EER ERA 2 6 Full Reset Buttf ll toe ske ssh EE pie eRe pies EG adits 2 6 Port Guder BEGRENS ee ereer urrera eee 2 7 Port Card Front Panel Lights and Controls sie ses ek eee se 2 7 Reset BUttON c esee Le eH SIS ER LORS GE D REI SHEER diens 2 7 Power Supply Lights i ss Wan aes Vos raped Pape p en ars 2 7 Active LUGE AE AE kine s Da ea b re oe ROC AE EAD M 2 9 VOX Lights EER EE OE Heel EN Dea dede E bean 2 9 Fiame Data Eig Ese EA ssk GEROER Bg ie Ge 2 9 Status Lights e RO Lon eet Cad
88. rix and are not serviceable by field personnel The following procedure helps you to isolate where the trouble is occurring 1 Swap the CPU cards Put the first card in the second CPU slot and the second card in the first CPU slot The problem will follow the card or the slot If the power supply lights do not illuminate on the bad card the card with the lights out when it is inserted in the other CPU slot the problem is probably in the card If the power supply lights on the bad card illuminate when the card is inserted in the other CPU slot the problem is probably not in the card itself The problem may be with the backplane connectors or power supplies 2 Check the power supplies alarm lights If the alarm lights are indicating a problem with the power supply swap it out with a new power supply If this repairs the problem the problem was in the power supply If the problem persists even after the power supply has been replaced the problem is in the backplane Send the matrix back to Clear Com for repair or replacement In the meantime you can substitute another matrix for the damaged one Clear Com will send you a substitute matrix to use while the damaged one is being repaired Problem The power supply lights are out on both CPU cards The problem may be with power supplies since both cards appear not to be receiving power Although less likely the problem may be in the matrix s backplane connectors
89. rring on one ring whilst the other ring remains intact the active ring always attempts to heal itself Switching to the secondary ring will cause audio breaks or disturbances and temporary loss of crosspoint data The self healing mechanism is performed autonomously by the fiber linking card whereas the switch over between redundant cards and rings requires software or operator intervention In all fault cases involving recoverable cable faults or loss of nodes on one or both both rings the remaining nodes may experience audio breaks or disturbances and temporary loss of crosspoint information or data Audio and data from a failed node will not be available to the remaining nodes for the duration of the failure When a ring with non adjacent failures sub divides into two sub rings audio and data from the failed nodes will not be available to the nodes in either sub ring audio and data will continue to be available to nodes within the same sub ring but data may still be available to all nodes that are still functioning if there is an intact independent Ethernet connection to those nodes If a Matrix frame connected as a node of the fiber optic link is reset powered down or failed this will constitute a lost or failed node on both rings and this node will experience audio breaks or disturbances and loss of crosspoint information or data for up to 5 seconds after the fault condition is cleared or repaired Single Card Set Redundant System F
90. s Port Card A port card controls the operation of panels and interfaces connected to it Panels and interfaces connect to the port card through an RJ 45 connector or port on the matrix s rear panel Shielded category 5 cable attaches the panel or interface to the RJ 45 connector The MVX A16 analog port card sends balanced audio and RS 422 data signals to connected audio equipment through 4 pair shielded category 5 cable The card connects up to 16 audio devices such as intercom panels interfaces or 4 wire audio equipment to the central matrix Each audio device connected to a port card communicates with all other audio devices in the system and with the central matrix For intelligent linking shielded category 5 cable is run from a port on one Eclipse Omega matrix to a port on a second Eclipse Omega matrix to form a trunkline connection ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 3 Fiber Card Fiber cards connect Eclipse matrices together to provide a high speed dual redundant link to transfer audio samples and data between systems These connections can be configured in various ways to provide protection against the loss of a link or a node Each fiber card link consists of a front card with various status indicators and a rear card with two Duplex LC Terminated fiber optic connectors TXVRA and TXVRB E Oue Card The E QUE cards allows the Eclipse matrix to connect to FreeSpeak CellCom antennas and FreeSpeak C
91. se Part 2 Immunity UL 60065 7 CAN CSA C22 2 No 60065 3 IEC 60065 7 Safety requirements And thereby compliance with the requirement of Electromagnetic Compatibility Directive 2004 108 EC and Low Voltage Directive 2006 95 EC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL The Eclipse Omega matrix houses up to 240 ports and dual redundant power supplies in a six rack unit chassis THE ECLIPSE OMEGA MATRIX SYSTEM AN OVERVIEW The Eclipse range of matrices comes in three frame formats The Eclipse Omega matrix is the largest with 15 client card slots providing up to 240 ports in six rack units GRU The other members of the Eclipse family are the Median with slots for up to 7 client cards and 8 interface modules in six rack units 6RU and the PiCo with up to 36 panel and 4 wire ports in one rack unit 1RU Clear Com designed the Eclipse Omega matrix with modular components that help you to plan build or customize your communication system to meet the most rigorous demands of modern broadcast performing arts industrial aerospace and military environments FEATURES Features of the Eclipse Omega matrix system include Full audio bandwidth throughout t
92. ster CPU card generates an alarm An alarm condition activates the relay contacts connected to pins 4 5 and 9 These contacts are dry no voltage is supplied to them by the matrix and are rated at 1 A at 24 VDC They should not be used for AC mains line current Pins are provided for adding an additional alarm source to the matrix s alarm system Pin 6 is an alarm input to the Eclipse Omega matrix It is connected to the input of a 3 3 V logic device A logic high on this input will cause the Eclipse Omega matrix to detect an alarm condition A logic low or an open circuit will cause the Eclipse Omega matrix to detect no alarm condition Pin 1 is a voltage source out of the Eclipse Omega matrix It is connected through a 10Kohm pull up resistor to the 5 V supply rail inside the Eclipse Omega matrix A contact closure placed across pins 1 and 6 will also cause an alarm condition The alarm outputs of the PSU 101 power supply could be wired directly to these pins allowing the CPU card to report PSU failures also To Alarm PSU 101 Alarm Relay To Alarm Connector Eclipse Alarm I O DB 9F Connector Relay Normally Closed Relay Normally Open Relay Wiper Common Figure 5 7 Wiring the Alarm I O Connector to an Alarm Relay Connector ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 5 11 gt gt ALARM COM i pL ALARM NC 9 gt gt ALARM NO l 10 E RLI RELAY DPDT Figure 5 8 Eclipse Ome
93. sued to a remote location to alert operators that part of a power supply has failed The failure of a single supply will issue an alarm but the Eclipse Omega system will continue to operate normally powered by the second supply HOT PATCHABILITY All CPU cards port cards and all Euro Cassette power supplies are hot patchable that is they can be plugged in or removed from the matrix while the power is on and they will be neither damaged nor will they cause damage to the system In addition the system smoothly incorporates a newly added card Sometimes re inserting a CPU card can reset the matrix Replace CPU cards during maintenance down times if possible ONBOARD PROCESSORS If one port card malfunctions the malfunction will normally affect only the panels connected to that port card The malfunction should not affect any other cards or panels in the system In all cases removing a faulty card affects only the devices connected to that card FAIL SAFE COMMUNICATION In the event of a CPU card failure the second CPU card takes over operation of the system while the first card is repaired or replaced TROUBLESHOOTING When attempting to identify the cause of the trouble it is helpful to begin with the two most basic areas which cause malfunctions The flow of electric current from the power supplies to the cards ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL The flow of data between the program software the circui
94. t button and various status indicators and a rear card with eleven RJ45 ports giving eight standard ports DECT sync in and out and a LAN port Each E Que front card has status LEDs for power port activity and LAN status The port activity LEDs indicate whether there is a device connected to an El port and that a connection has been established between this port and the connected device The E Que cards must be fitted in the rightmost available slots on the Omega furthest from the config cards and up to four E Que cards can be fitted on a matrix Note It is not necessary to bave an ethernet cable connected to tbe E Que card LAN port for the card to function correctly E QUE CARD FRONT PANEL LIGHTS OD Reset Button Pressing the reset button causes the card and all links to momentarily stop their current activity and to restart During the reset configuration information downloads to the card from the CPU card If the entire system is operating except for one E Que card press the reset button for that card only Note The reset button is slightly recessed from the front panel to prevent it from being accidentally pressed You need a tool such as a bent paper clip to press this button Q Power Supply amp Status Lights 3 3 Volt Power Supply Light ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 4 1 4 2 The matrix s 3 3 volt power supply provides electric current to this green light When lit the light indicates that the 3
95. t cards and the attached audio devices The following sections discuss troubleshooting these two basic categories of problems TROUBLESHOOTING POWER SUPPLY PROBLEMS General Principles Electric current in the matrix starts at the power supplies travels through the matrix s backplane connectors and then travels to the circuit cards themselves When power supply problems occur those three areas the power supplies the backplane connectors and the circuit cards should be explored to identify where the trouble is occurring Solving power supply problems starts with identifying the specific component causing the problem Note The matrixs backplane connectors are part of the matrix s infrastructure and are not serviceable by field personnel If you determine that a problem is in the matrix s backplane connectors you must send the matrix in for repair Backplane connector malfunctions are rare but should be considered as possiblities Clear Com will ship a spare matrix to use while the damaged matrix is being repaired If you need to send any equipment back to Clear Com follow the procedure described in the Warranty chapter of this manual for obtaining a return authorization number from the Clear Com Service Department A lit power supply light on a component indicates that the matrix s electric current has traveled successfully to that component and is powering the component For example if the power supply lights on the CPU
96. t component Problem The power supply lights do not illuminate on all cards in the matrix In this situation the most probable problem is that the matrix s power supplies are not sending out any electric current since none of the cards are receiving power Although less likely the problem may be in the matrix s backplane connectors The following procedure helps you isolate where the trouble is occurring Check the power supplies alarm lights If the power alarm lights are indicating a problem with the power supply swap it out with a new power supply f this repairs the problem the problem was in the power supply If the problem persists even after the power supply has been replaced the problem is in the matrix s backplane connectors Send the matrix back to Clear Com for repair or replacement In the meantime another matrix can ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL be substituted for the damaged one Clear Com will send you a matrix to use while the damaged one is being repaired Problem The power supply lights do not illuminate on one of the two CPU cards When the system is functioning properly the power supply lights on both CPU cards illuminate If the power supply lights on a CPU card fail to illuminate the problem may be with the card itself or with the backplane connectors that carry the electric current from the power supplies to the cards The backplane connectors are part of the infrastructure of the mat
97. the CPU card you must reconnect the card s battery The CPU card is shipped with a disconnected battery to preserve battery life For instructions on reconnecting the battery see RAM Back Up Battery on pages 3 3 and 3 4 Store spare CPU cards in unused slots in the matrix or in electrically insulated packaging such as anti static heavy duty plastic bags To insert a CPU card in the matrix 1 Carefully place the card in the appropriate slot Make sure the card is aligned with the top and bottom precision guides 2 When the card has almost reached the backplane connectors open the two ejectors allowing them to clear the edges of the matrix Gently insert the card further until it touches the backplane connector guides 3 Gently close both ejector tabs at the same time which will propel the card into the backplane connectors To remove a CPU card from the matrix 1 Two card ejector tabs located at the top and bottom of the CPU card hold the card in place in the matrix To remove a card open the two ejector tabs at the same time until the card unseats from its backplane connectors 2 Pull the card out of the matrix HOT PATCHING The CPU cards are hot patchable and self initializing When the matrix is fitted with two CPU cards a faulty CPU card can be removed and replaced while the system is powered because the second CPU card will automatically begin operating when the first card is removed Sometimes re i
98. tion ECLIPSE 6RU 58mm max 0 to 40 C operating 55 to 70 C storage 40 90 non condensing 13 3V 6RU 300 mm 0 to 40 C operating 55 to 70 C storage 40 90 non condensing 3 3V 3 5A 5V 0 7A 12V 0 05A 6RU 58mm max 0 to 40 C operating 55 to 70 C storage 40 90 non condensing 6 RU 300 mm 16 bi directional Balanced Balanced None expected at User Panel Station 0 dBu nominal 100 Ohms balanced 30 Hz 22 kHz 3 dB lt 0 05 0 dBu 300 Hz to 10 kHz lt 0 1 0 dBu 100 Hz to 20 kHz 0 dBv nominal 600 Ohms balanced 30 Hz 22 kHz 3 dB lt 0 05 0 dBu 300 Hz to 10 kHz lt 0 1 0 dBu 100 Hz to 20 kHz RS 422 2400 to 19200 kb s RS 422 2400 to 19200 kb s 100 ohm 1096 None expected at User Station None expected at User Station OMEGA MATRIX INSTRUCTION MANUAL Backplane Connector FCI BERG Metral Port Connector RJ 45 to Clear Com standard pinout Transmission Distance 3000 ft 1000 m maximum System Programming Group Calls 100 Number of Grouped Ports 4000 maximum Conferences per Matrix 64 IFB per Matrix 100 Priority Levels 5 Isolates Any crosspoint Listen Level Control 0 71 dB steps Input Level Control 0 355 dB steps Output Level Control 0 355 dB steps VOX Input Detection Threshold 0 dB to 32 dB adjustable Minimum PC Requirements Processor Pentium III 600 MHz minimum recommended Memory 512 MB RAM minimum
99. u must fit the following filter between the PROC RCC socket and the cable CINCH FA 25PS 1 25W D type in line 1000pF filter UK supplier Farnell 322 2676 5 GENERAL PURPOSE INPUTS CONNECTOR GP IN The female 25 pin D type socket labeled GP IN connects the Eclipse Omega CPU card to eight general purpose inputs GPIs You can connect an external logic device such as an external foot switch a panel mounted switch or the logic output of some other device to the GP IN connector When the external logic device is activated it sends a control signal into the matrix to perform one of several preset functions such as turning an ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL 2 17 intercom panel s microphone on or off muting a microphone s output or turning a panel s speaker off You choose the function to perform and the panel upon which it is performed from the assignment program LOCAL AREA NETWORK I CONNECTOR LAN 1 The RJ 45 socket labeled LAN 1 connects a local area network LAN to the CPU card through a standard Ethernet connection The green LED indicates the port is connected and the amber LED indicates activity If you use this port you must add a ferrite to the socket end of each cable A suitable ferrite is Wiirth Electronik part 74271132 D LOCAL AREA NETWORK 2 CONNECTOR LAN 2 The RJ 45 socket labeled LAN 2 connects a second local area network LAN to the CPU card throu
100. y 5 cable to a port to carry signals from the Eclipse Omega circuit cards to connected intercom panels or interfaces ECLIPSE CONFIGURATION SYSTEM ECS The Eclipse Configuration System ECS controls the operation of the remotely connected audio devices by sending signals to the circuit cards in the matrix which then relay the signals to the audio devices ECLIPSE OMEGA MATRIX INSTRUCTION MANUAL Configurations which are the operating parameters of complete system setups can be created from the connected computer You can store four complete system configurations in the computer s memory to retrieve and activate when needed The Eclipse Configuration System runs on three versions of Windows Windows XP Windows Server 2003 and Windows 2000 When running ECS on the three Windows operating systems the client and server can run on separate machines connected over a network From the Eclipse Configuration Software you can create point to point and fixed group or party line communications among the connected audio devices assign a label to each port panel and inhibit or enable features at any connected panel You can set up the system to run on a client server model over a network allowing you to control the matrix remotely INTERCOM PANELS AND ACCESSORY PANELS All intercom panels connect to the central matrix via shielded category 5 cable terminated with RJ 45 connectors The shielded category 5 cable connects to the