Home
        ZyXEL Communications G-200 User`s guide
         Contents
1.      Encryption    Turn on the encryption to encode the communications between the SP 200E and the  hotspot or service gateway  When you use the encryption  the data is unreadable to  anyone that does not know the secret key  This protects against people stealing  account information or creating illegitimate accounts  To use encryption  you must  also configure the secret key in the following field and on the hotspot or service  gateway        Secret key    When you use encryption  enter a code here  You can use up to 8 ASCII characters   You must also configure the same code as the secret key on the hotspot or service  gateway        Apply    Click Apply to save the changes        Renew Password    Enter a new password for accessing the SP 200E  This field is case sensitive  Make  sure you keep your password in a safe place  If you lose or forget it  you will need to  press the RST  reset  button on the SP 200E rear panel to restore the default  settings  This erases all of your configuration        Confirm Password    Retype your password to make sure you have entered it correctly           Apply       Click Apply to save the changes           4 3 Firmware Upload    To upgrade the firmware  you first have to download the latest firmware from www zyxel com and then  use the web configurator to upload it to the SP 200E  The firmware will include the device name  SP   200E  and end with a  bin extension     SP 200E User    s Start Guide    After you enter the user name and pas
2.     Do NOT allow anything to rest on the power adaptor or cord and do NOT place the product where anyone can  walk on the power adaptor or cord     Do NOT use the device if the power adaptor or cord is damaged as it might cause electrocution   If the power adaptor or cord is damaged  remove it from the power outlet     10       SP 200E User    s Start Guide    e Never disassemble the printer or the adapter   e Do NOT attempt to repair the power adaptor or cord  Contact your local vendor to order a new one     e Do not use the device outside  and make sure all the connections are indoors  There is a remote risk of electric  shock from lightning     e This product is recyclable  Dispose of it properly        8 Procedure to View a Product   s Certification s     1 Go to www zyxel com   2 Select your product from the drop down list box on the ZyXEL home page to go to that product s page   3 Select the certification you wish to view from this page     11    
3.   account information  using the statement          Make sure there is enough printing paper in the statement printer              printer  Make sure you set the gateway to require authentication before allowing Internet access   see the Wizard Setup screens or the Authentication chapter  refer to the gateway User   s  Guide     7 Safety Warnings    Do NOT use this product near water  for example  in a wet basement or near a swimming pool   Do NOT expose your device to dampness  dust or corrosive liquids   Do NOT store things on the device     Do NOT install  use  or service this device during a thunderstorm  There is a remote risk of electric shock from  lightning     Connect ONLY suitable accessories to the device    Never touch the thermal printing head immediately after printing because it becomes very hot    Make sure that the thermal printing head is cool before inserting a paper roll or cleaning the thermal printer   Do not connect the statement printer   s RJ 45 connector to the telephone network    Make sure to connect the cables to the correct ports    Place connecting cables carefully so that no one will step on them or stumble over them     The PoE  Power over Ethernet  devices that supply or receive power and their connected Ethernet cables must  all be completely indoors     Use ONLY an appropriate power adaptor or cord for your device     Connect the power adaptor or cord to the right supply voltage  for example  110V AC in North America or 230V  AC in Europe  
4.   mm   Paper Roll Inside Diameter 12  0 5  0  mm    Printing Speed 25 4 mm   second    Dot Resolution 8 dots   mm  203 dpi     Dot Configuration 384 dots   line    Paper Detection Photo interrupter    Thermal Head Service Life 108 pulses or 50 Km    Paper Thickness 65 um    Dot Resolution 8  dots   mm   203 dpi     Communication Interface Ethernet port  RJ 45   LED on port  100 Mbps Link ACT  yellow   10 Mbps Link ACT  green  Supported Protocols  ARP  IP  ICMP  UDP  TCP  HTTP    Communication Cable Type Ethernet  Communication Cable Length up to 100 meters  PS 2 Keypad Interface PS 2 port for optional 16 Key  PS 2 keypad    PS 2 Keypad Interface Acceptable  0123456789        Enter     Characters    TOW    155    SOFT T    Operating Temperature 0 to 50 degrees Celsius  Storage Temperature  20 to 60 degrees Celsius  Operational Humidity 10   80 RH  non condensing     Storage Humidity 10   95 RH  non condensing     Certification VCCI  C Tick  CE  FCC CSA       SP 200E User    s Start Guide    6 Troubleshooting    Table 5 Troubleshooting       Problem Corrective Action       The push button Make sure that you have the correct power adaptor connected to the printer and plugged in  LEDs are off  to an appropriate power source  Check all cable connections     If the front panel button LEDs still do not turn on  you may have a hardware problem  In this  case  you should contact your local vendor          cannot print the Check that the statement printer is connected to the gateway   
5.  Guide    e Click Setup to log in if you want to configure the SP 200E  see section 4 2      e Click Firmware Upgrade if you want to upload firmware  see section 4 3      admin    irmware Version VAT OOLAN OVCO    O0 S0 0E 01 54 F 4    Firmware Upgrade      Note  The SP 200E automatically logs you out if there is no activity for longer than five minutes after  you log in  If this happens  simply log back in again        4 2 Configuration    The Setup screen displays after you enter the user name and password and click Setup     SETUP    Basic        IP Address 192 fies fi   Subnet Mask ps   ps fs   Destination IP Address he   fes ft  Port foor  10011005        Disable    secret Key     max   amp  characters   Apply      Change Password    Renew Password    max   amp  characters   Confirm Password    max   amp  characters     Apply         Table 3 Setup Screen    SP 200E User    s Start Guide       LABEL    DESCRIPTION       IP Address    The SP 200E uses a static IP address  Enter the IP address in dotted decimal  notation  The default is 192 168 1 7  You must also enter it in the hotspot or service  gateway        Subnet Mask    Enter the subnet mask in dotted decimal notation  The default is 255 255 255 0        Destination IP address    Enter the IP address of the hotspot or service gateway        Port    Enter the port number that the SP 200E uses when communicating with the hotspot  or service gateway  The hotspot or service gateway must also use the same port  number   
6. SP 200E    Statement Printer    User   s Guide    Version 1 00  7 2006  Edition 1       ZyXEL    Copyright    2006 ZyXEL Communications Corporation  All rights reserved     SP 200E User    s Start Guide    1 Introducing the SP 200E    The SP 200E is a 2 inch thermal printer with an integrated  easy to use  push button control panel  It lets you  generate subscriber accounts and print account information with the push of a button  It is also compact and  portable and does not need a computer or printer  It is ideal for offices  coffee shops  libraries  hotels and  airport terminals that provide Internet access for customers     You can connect multiple SP 200Es to a single hotspot or service gateway to generate accounts in different  locations     2 Hardware Descriptions and Connections    2 1 Front Panel  1 Cover  2 Paper roll housing  3 Printing head  4 Buttons A C  5 Cover release button  6 Tear bar       SP 200E User    s Start Guide    2 2 Rear Panel  1 Reset button  2 Power switch  3 DC power socket  4 Ethernet port  RJ 45   5 PS 2 keypad port       Table 1 Rear Panel Hardware                Label Description   RST Press this button for 10 seconds to restore the factory default settings  The default IP  address is 192 168 1 1    ON OFF Use this power switch to turn the printer on or off    DC Use the printer   s included power adaptor to connect this power socket to a power supply        POE RJ 45 port Use an Ethernet cable to connect this port to the gateway  You can us
7. e a mid span POE   Power Over Ethernet  injector  not included  instead of the power adaptor    Yellow LED  100 Mbps Link ACT  This LED comes on when there is a 100 Mbps connection  and blinks when sending or receiving traffic    Green LED  10 Mbps Link ACT  green  This LED comes on when there is a 10 Mbps  connection and blinks when sending or receiving traffic        PS 2 keypad port   Connect an optional PS 2 keypad to this port  Refer to the hotspot gateway User   s Guide for  information on how to configure the gateway for use with the SP 200E and the optional PS   2 keypad                 SP 200E User    s Start Guide    2 3 Front Panel Push Buttons    Push the power switch to ON  The buttons on the front panel light up when the statement printer is receiving  power  The following table describes push button   s LED status and functions     Note  If the printer prints continuously for two minutes  you must stop printing for at least eight minutes     Table 2 Front Panel Push Buttons       LED Status   Printer mode   Function          All Button All of the printer   s functions are stopped   LEDs Off Hold button A down while you turn on the power to have the printer print a self   test     All Button On  Ready  Push a button to create a customer account with the configured account service       LEDs On period  Refer to the gateway User   s Guide for information on how to configure the   Green  gateway for use with the SP 200E    Button A Out of paper    No function    Bl
8. inking Cover open    Green              3 Loading Paper Rolls    Use the following steps to prepare the statement printer for use with a gateway     1 Push the cover release button  2 Open the cover           SP 200E User    s Start Guide    3 Set a paper roll in the printer so that it unrolls 4 Pull some paper out to start the roll   from the bottom     Press down on the middle of the cover to close it  do  not press on only one side of the cover   Press firmly  until you feel the cover lock into the closed position     5 Hold button A down to print a self test  Pull the paper  down across the tear bar from one side to the other  to cut it        4 Web Configurator    The web configurator allows you to change the SP 200E   s IP address or encryption key  You should also  change the SP 200E   s password     4 1 Web Configurator Login  Follow the steps below to access and use the web configurator   Note  The SP 200E allows only one web configurator session at a time     1 Give your computer a static IP address between 192 168 1 1 and 192 168 1 254  but do not use  192 168 1 7  and connect your computer directly to the Ethernet port     2 Launch your web browser and type 192 168 1 7 as the web address    File Edit View Favorites Tools Help    4m Back          fai   Search  Ge  Favor  Address    3 A login screen displays  Type    admin     default  as the user name and  1234   default  as the password   The user name and password are case sensitive        SP 200E User    s Start
9. sword and click Firmware Upgrade in the login screen  you need to wait  a moment and click Continue to display the Firmware Upgrade screen     Firmware Upgrade  File Location   Hame Browse      APPLY      CANCEL       Hote  System will be rebooted when press Apply or Cancel      Upgrading firmware may take 60 seconds     jee    Upgrade must NOT be interrupted         Specify the name of the firmware file in the Local PC File Path field or click Browse to locate the file and click  Apply to start the file transfer process  The firmware must be a binary file and should have a  bin extension     Note  WARNING   Do not close the browser or disconnect or turn off the SP 200E  as interrupting the file  upload process may PERMANENTLY damage the device     When the upgrade is completed successfully  click Re Login to return to the login screen where you can check  the firmware version     5 Specifications    Table 4 Specifications  Power Adapter MUT15 050250    Power Adapter Input Voltage AC 100   240 Volts  Power Adapter Output Power 5V  2 5A    Power Power Consumption   12 12 Watts Max  Max     Power eee Ethernet  POE  Ha with mid span Power Over Ethernet  PoE  injectors  receives  power on pins 4  5  7 and 8        SP 200E User    s Start Guide    Paper Width 58  0  1  mm   Number of Statements Per Paper   A single account statement is around 15 cm in length  You should be able to  Roll print about 333 account statements on a 50 m paper roll    Paper Roll Outside Diameter 63  2  2
    