Home

Carrier 48GL Datasheet

image

Contents

1. E I O Functions Stat Starts time measurement Interrupts time measurement and resets time measurement value No time measurement is made and control output is OFF while the reset input is ON Prohibits time measurement Outputs Control output Outputs are turned ON according to designated output mode when preset value is reached Solid state Timer H3BA N 5 ll Basic Setting Setting of Selector The selectors can be turned clockwise and counterclockwise to select the desired time unit time range output type only for H3BA N8H or operating mode Each selector has a snap mechanism that secures the selector at a given position Set the selector at a position at which it is secured Do not set it midway between two securing positions or a malfunction could result from improper setting Operating mode selector Output type selector UE Operating mode Output type display window D Groove for screwdriver Selection of Operating Mode with H3BA N Turn the operating mode selector with a screwdriver until the desired operating mode A B B2 C D or E appears in the display window located above the selector Selection of Output Type with H3BA N8H Turn the output type selector with a screwdriver until the desired out put type A or H appears in the display window located above the selector Selection of Time Unit and Time Range The desired time unit sec min hrs or 10h
2. Solid state Timer HSBA N T Operating mode Timing chart D Signal OFF delay Power 2 and 10 Start 2 and 6 Reset 2and7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator Basic operation E Interval Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator Basic operation Gate Signal Input in Operating Mode A ON delay Operation t ON 3 Power OFF amp ON Start OFF ON Gate OFF ON Reset OFF Output ON relay OFF Note The set time is the sum of t Solid state Timer H3BA N OMRON H3BA N8H Output Type A Type A ON delay Power 2 and 7 Output relay NC 8 and 5 1 and 4 Output relay NO 8 and 6 1 and 3 and output indicator Power indicator Basic operation Power Output H3BA N8H Output Type H Type H ON delay with E TN instantaneous output g contact Power 2 and 7 Output relay 8 and 5 NC Output relay 8 and 6 NO output indicator E Instantaneous 1 and 4 output relay NC Instantaneous 1 and 3 output relay NO Power indicator _ Basic operation Power Output Solid state Timer H
3. application will be able to use a time setting as close as the full scale time setting of the Timer Others When conducting a dielectric test impulse voltage test or insulation resistance test between the electric circuit and non current carrying metal parts of the Timer mounted to a control panel be sure to take the following steps These steps will prevent the internal circuitry of the Timer from damage that may be caused if a machine on the control panel has an improper dielectric strength or insulation resistance 1 Separate the Timer from the circuitry of the control panel by disconnecting the socket from the Timer or wires 2 Short circuit all terminals of the Timer If any device with no contact output such as a proximity sensor photoelectric sensor or SSR is directly connected to the Timer current leakage from the device may cause Timer malfunction Be sure to test the device with the Timer before using the device for actual applications Before using the Timer to switch inductive loads be sure to connect a surge absorbing element to the Timer in order to prevent the Timer from malfunction and damage A diode is an example of a surge absorbing element for DC circuits and a surge absorber is an example of a surge absorbing element for AC circuits Do not leave the Timer in time up condition for a month or longer in places with high temperatures otherwise the internal parts such as an electrolytic capacitor of the Tim
4. 847 843 7900 800 556 6766 www omron247 com OMRON CANADA INC HEAD OFFICE OMRON ARGENTINA SALES OFFICE Toronto ON Canada 416 286 6465 866 986 6766 www omron247 com Cono Sur 54 11 4783 5300 OMRON ELETR NICA DO BRASIL LTDA HEAD OFFICE OMRON CHILE SALES OFFICE S o Paulo SP Brasil e 55 11 2101 6300 www omron com br Santiago 56 9 9917 3920 OMRON ELECTRONICS MEXICO SA DE CV HEAD OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca N L e 52 811 156 99 10 001 800 556 6766 mela omron com 54 11 4783 5300 2009 Omron Electronics LLC Cat No LO93 E1 02A Specifications are subject to change without notice Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery amp Lifecycle Information Omron H3BA N8H 110VAC H3BA N8H 220 VAC H3BA N 110 VAC
5. and range Panel Cover Y92P 48GL 48GB or 48GA Y92S 27 Y92S 28 Y92S 28 Time Setting A Time Setting B Time Setting C Y92P 48GL Y92P 48GB Light Gray Black Hold down Clip Y92H 1 For PLO8 Socket Y92P 48GM Medium Gray Y92H 2 For PF085A Socket Solid state Timer H3BA N 13 omnmnon Installation Terminal Arrangement H3BA N Contact Output y 0g A 4 oo H3BA N8H Contact Output Reset input Start input Gate input Note The delayed contacts of conventional timers are shown as follows The contact symbol of the H3BA N is ex e pressed as follows because of its multiple op ag erating modes oA O i HO i H Exc sul The instantaneous contacts of conventional MODE See note Power supply timers are shown as follows ar 3C Note The output contact can be set to either instantaneous or time limit contact using the output type selector located at the upper right corner of the front panel eve 14 Solid state Timer H3BA N Input Connections The inputs of the H3BA N are no voltage short circuit or open inputs No voltage Inputs No contact Input Connection to NPN open collector output sensor 12 to 24 VDC sensor power supply supply Tim
6. is displayed in the window below the time setting knob by turning the time unit selector located at the lower right corner of the front panel A time range 1 2 3 12 or 30 is selected with the time range selector at the lower left corner of the front panel and the selected time range appears in the window at the lower right part within the plastic frame of the time setting knob N Operating mode display window Time range selector Time unit selector Time unit display window Setting of Time Use the time setting knob to set the desired time OMRON E Using the Setting Ring Setting a Specific Time Mount the Panel Cover on the Timer set the desired time with the time setting knob and place Time Setting Ring A onto the time setting knob so that the time setting notch of Time Setting Ring A is in the center of the reset lock position of the Panel Cover Time setting Reset lock position notch gt gt Time setting ring Panel cover Example To set the time to 10 s Limiting the Setting Range Example To set a range of 10 and 20 s Mount the Panel Cover on the Timer set the time setting knob to 10 s the lower limit of the setting range and place Time Setting Ring C onto the time setting knob so that the stopper of Time Setting Ring C is on the right edge of the reset lock position of the Panel cover Next set the time setting knob to 20 s the upper limit of the setting range p
7. shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases but the following is a non exhaustive list of applications for which particular attention must be given i Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document ii Use in consumer products or any use in significant quantities iii Energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equip ment and installations subject to separate industry or government regulations iv Systems machines and equipment that could present a risk to life or prop erty Please know and observe all prohibitions of use applicable to this Prod uct NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON S PRODUCT IS PROP ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is pro
8. the Timer is used continuously at a high ambient temperature Solid state Timer H3BA N 3 OMRON B Characteristics H3BA NSH Accuracy of operating time 0 3 FS max 0 3 10 ms in a range of 1 2 s Setting error 5 FS 0 05 s max Reset time Min power opening time 0 1 s max Min pulse input time 50 ms Influence of voltage 0 5 FS max 0 5 10 ms in a range of 1 2 s Influence of temperature 2 FS max 2 10 ms in a range of 1 2 s Insulation resistance 100 MQ min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying metal parts and exposed non current carrying metal parts 2 000 VAC 50 60 Hz for 1 min between control output terminals and operating circuit 1 000 VAC 50 60 Hz for 1 min between contacts not located next to each other 750 VAC for H3BA N8H Impulse withstand voltage 1 kV between power terminals 2 kV between current carrying terminal and exposed non current carrying metal parts 1 5 kV for 24 VDC models Noise immunity AC models 1 5 kV between power terminals and 600 V between input terminals square wave noise by noise simulator pulse width 100 ns 1 us 1 ns rise DC models 480 V between power terminals and 600 V between input terminals square wave noise by noise simulator pulse width 100 ns 1 us 1 ns rise Static immunity Malfunction 4 kV ___ _ _ ___ Vibration resistance Destruction 10 to 55 Hz with 0 75 mm
9. 3BA N 9 omrRon Dimensions Note All units are in millimeters unless otherwise indicated H3BA N 44 8 x 44 8 sd s D 2 v Lars LOTT 2 S mS SN V Time setting ring Panel cover Dimensions with Y92F 30 Flush Mounting Adapter P3G Back Connecting Socket sold separately Panel Cutout Note The mounting panel thickness should be 1 to 5 mm 0 5 R max 06 N 4510 10 Solid state Timer H3BA N Dimensions with Y92F 70 Flush Mounting Adapter 45 0 15 58 Flush Mounting Y92F 30 P3GA 11 P2CF 11 2 3 P2CF 08 23 Note These dimensions vary with the kind of DIN track reference value RO 5 max 52 to 53 Panel Cutout OMRON Adapter mounting hole Two 4 5 dia Neb 31 or 65 to 66 76 0 2 RO 5 max 45705 EN 55105 y Note The mounting panel thickness should be 1 to 3 2 mm Solid state Timer H3BA N 11 omn on Accessories Order Separately Track Mounting Front Connecting Socket P2CF 08 cn Terminal Arrangement 4 7 5 sems 7 8 Internal Connections Top View Surface Mounting Holes Two 4 5 dia or two M4 f J zel Bel 70 max 6 ENA ol Y Ci oy LT Two 4 5 dia holes 20 3 Two 4 5 dia or two 4 M 40 0 2 gt 31 2 max
10. Back Connecting Socket P3G 08 Terminal Arrangement 27 dia Internal Connections Bottom View 27 dia Mounting Track PFP 100N PFP 50N L Length 1m PFP 100N 50 PFP 50N PFP 100N2 12 Solid state Timer H3BA N End Plate PFP M Protective Cover Y92A 48B The protective cover protects the front panel particularly the time setting section against dust dirt and water It also prevents the set value from being altered due to accidental contact with the time setting knob Note 1 The Y92A 48B Protective Cover is made of a hard plastic and therefore it must be removed to change the timer set value 2 The Protective Cover cannot be mounted if the Panel Cov er sold separately is used on the Timer Y92A 48B OmRON Time Setting Ring Panel Cover There are three types of Panel Covers Y92P 48GL Y92P 48GB Y92P 48GM all of which are available in three colors Use the most suitable type of Panel Cover with the design of the scaling plate according to the application When setting a given time for the Timer use of the Y92S 27 or Y92S 28 Time Setting Ring facilitates the time setting operation and minimizes possible setting errors by operators The Time Setting Ring and Panel Cover should be used as a pair Setting a specific time Time Setting Ring A Y92S 27 and Panel Cover Y92P 48GL 48GB or 48GM Limiting the setting Time Setting Ring or Y92S 28
11. DT time limit lt instantaneous Ordering Information B List of Models Control output Supply voltage 11 pin models 8 pin models Contact output DPDT time limit output 110 VAC 50 60 Hz H3BA N 110 VAC 220 VAC 50 60 Hz H3BA N 220 VAC 24 VDC H3BA N 24 VDC Contact output Time limit SPDT and 110 VAC 50 60 Hz H3BA N8H 110 VAC switchable SPDT 220 VAC 50 60 Hz H3BA N8H 220 VAC time limit lt instantaneous Accessories Order Separately Name specifications Models Flush Mounting Adapters lt lt lt Q P N Tin o PFP 50N PFP 100N PFP 100N2 PFP M PFP S Y92A 48B P2CF 08 P2CF 11 P3G 08 P3GA 11 925 27 925 28 Y92P 48GL Y92P 48GB Y92P 48GM Y92H 1 Y92H 2 Mounting Tracks 50 cm x 7 3 mm t 1 m 1 x 7 3 mm t 1 m 1 x 16 mm t End Plate Protective Cover Track Mounting Front Connecting Sockets Back Connecting Sockets Time Setting Ranges Setting a specific time Limiting the setting range Light gray 5Y7 1 Black N1 5 Medium gray 5Y5 1 Hold down Clips See note 2 For 08 Socket For PF085A Socket Note 1 The Time Setting Ring and Panel Cover are sold together 2 Hold down Clips are sold in sets of two Panel Covers See note 1 2 Solid state Timer H3BA N omnon Specifications B General a H3BANSH Operating mode A ON delay A ON delay B Flicker OFF start H ON delay with instantaneous output contac
12. OMRON Solid state Timer H3BA N Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Refer to Warranty and Application Considerations page 20 and Safety Precautions page 16 Solid state Timer with Valuable Multiple time Ranges and Multiple operating Modes Handles a wide range of applications through six operating modes e With H3BA N8H models the output type can be switched between time limit DPDT and time limit SPDT instantaneous SPDT using a selector Setting rings order separately to enable consistent settings and to limit the setting range Panel Covers order separately to enable various panel designs Conforms to LR and approved by UL and CSA Broad Line up of H3B N Series Multi functional Timer Twin Timer Star delta Timer Power OFF delay Timer H3BA N 11 model H3BF N8 8 pin model H3BG N8 8 pin model H3BH N8 8 pin model H3BA N8H 8 pin with H3BG N8H 8 pin with instantaneous instantaneous contact output contact output and time limit output Note Refer to the H3BF N BG N BH N Datasheet Cat No LO94 E1 1 for details Solid state Timer H3BA N 1 omnon Model Number Structure Model Number Legend H3BA NUJ 1 1 Number of Pins Output None 11 pin models Time limit DPDT 8H 8 pin models Time limit SPDT and switchable SP
13. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products without regard to conflict of law princi ples d Amendment These Terms constitute the entire agreement between Buyer and Omron relating to the Products and no provision may be changed or waived unless in writing signed by the parties e Severability If any provi sion hereof is rendered ineffective or invalid such provision shall not invalidate any other provision f Setoff Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice g Definitions As used herein including means including without limitation and Omron Compa nies or similar words mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof Certain Precautions on Specifications and Use 1 Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyers application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Prod uct in combination with the end product machine system or other application or use Buyer
14. Time limit SPDT and Operating Mode Selector Select a mode from A B B2 C D and E Lit when Timer outputs p instantaneous SPDT Time Range Selector Scale Range Display Select one from Windows 1 2 3 12 and 30 Scale Range Display Time Range Selector Windows Select one from 1 2 3 12 and 30 a omRON H3BA omnon Time Unit Selector JA Time Unit Selector Time setting knob set time Select a unit from Time setting knob set time Select a unit from sec sec min hrs and 10h min hrs and 10 h 4 Solid state Timer H3BA N omnon Operation Block Diagrams H3BA N AC DC input Time range Operating unit selectors mode selector Power suppl Oscillation Countin circuit iis circuit circuit 9 Output circuit Reset input start input and gate input Input circuit gt gt wW wW Power ON Output ON indicator indicator H3BA N8H DC input Time range Output type unit selectors selector Z Power cupoly Oscillation Counting gt circuit circuit circuit Indicator circuit zr ET Power ON Output ON indicator indicator Instantaneous gt output circuit
15. e input signal terminals of the Timer when one of the input terminals terminals 5 6 and 7 and the common terminal terminal 2 for the input signals are short circuited Do not attempt to connect any input terminal to any terminal other than the common terminal or to apply voltage across other than the specified input and common terminals or the internal circuits of the Timer may be damaged L S Power supply See notez 5 6 7 G S Y Input contact Input terminal 2 see note 1 Y Note 1 Power supply terminal 2 is a common terminal for the input signals G S R to the Timer Never use terminal 10 as the common terminal for this purpose otherwise the internal circuit of the Timer may be damaged 2 Do not connect a relay or any other load between these two points otherwise the internal circuit of the Timer may be damaged due to the high tension voltage applied to the input terminals 16 Solid state Timer H3BA N Operating Time Setting When setting the operating time do not turn the setting knob beyond its scale range For precise time setting conduct operation tests by adjusting the setting knob The accuracy of the operating time of the Analog Timer is indicated by the percentage value on the basis of the full scale time The absolute fluctuation value will not be improved by changing the time setting Therefore when selecting the model be sure that the
16. e supply voltage is being applied otherwise an electric shock may occur B Precautions for Correct Use Changing the Setting Do not change the time unit time range or operation mode while the Timer is in operation otherwise the Timer may malfunction Connecting the Operating Power Supply The H3BA NL contains a capacitor drop power circuit Use a sinusoidal power supply with a commercial frequency Do not use power supplies with a high frequency component such as inverter power supplies for Timers with 110 or 220 VAC specifications Using these power supplies can damage internal circuits If voltages other than the rated voltage is applied the internal components may be damaged The internal element varistor will be damaged if a voltage of higher than 100 VAC is applied to the 24 VDC line Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately or the Timer may not be reset or a timer error could result A DC power supply can be connected if its ripple factor is 2096 or less and the mean voltage is within the rated operating voltage range of the Timer If the wiring to the terminal 2 common terminal for both the power supply and input signals is broken the internal circuit will be destroyed 5 6 7 Is G 5 ys M Input terminal T H3BA N Closed Input Output An appropriate input will be applied to th
17. er Sensor Start reset gate Input 0 V O No 2 pin Operates with transistor ON No voltage Input Signal Levels No contact 1 Short circuit level input Transistor ON Residual voltage 1 V max Contact Input Timer Start reset gate Input 0 V O No 2 pin Operates with relay ON Impedance when ON 1 max 2 Open level Transistor OFF Impedance when OFF 200 kQ min Use contacts which can adequately switch 0 1 mA at 5V No contact Input Connection to a voltage output sensor DC power supply 12 to 24 VDC sensor power supply Timer Start reset gate Input 0 V No 2 bin Operates with transistor ON OMRON Solid state Timer H3BA N 15 Safety Precautions OMRON PAN Ye Minor electric shock may occasionally occur Do not disassemble the product or touch the interior of the Timer Minor burns may occasionally occur Do not touch the product while power is being supplied or immediately after power is turned OFF Minor fires may occasionally occur Tighten terminal screws to a torque of 1 08 N m so that they do not become loose Minor electric shock may occasionally occur during operation Install the terminal cover Minor electric shock fire or malfunction may occasionally occur Do not allow metal fragments lead wire scraps or chips from processing during installati
18. er may be damaged Use the Timer with an appropriate relay so that the Timer will not be left in time up condition for a long time If the Timer is mounted in contact with a mounting surface the service life of internal parts may be shortened Provide at least 10 mm between the Timer and the mounting surface to prolong the service life of the Timer When the Timer is reset right after the Timer goes into time up condition be sure to provide the Timer with an appropriate circuit configuration considering the resetting time of the Timer so that a sequential error will not result The Timer uses the constant value read method Be careful when changing the set value because the output of the Timer will be ON when the set value coincides with the count value Be sure that the casing of the Timer is free from organic solvents such as paint thinner and benzene strong acid and alkali solvents which will damage the casing Note It is impossible to connect more than two Timers in parallel omnon E Mounting Surface Mounting There is no particular restriction on surface mounting directions but be sure that the Timer is securely mounted horizontally P2CF Socket When mounting the Timer vertically with the P2CF Socket consider the movable hooks and be sure that there is a 20 mm space on each of the upper and lower parts of the Socket P2CF 08 Solid state Timer H3BA N 17 PL Socket 1 Secure the Socket to the panel su
19. hall be responsible for and shall bear all costs involved in obtaining any government approvals required for the impor tation or sale of the Products Taxes All taxes duties and other governmental charges other than general real property and income taxes including any interest or penalties thereon imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture production sale delivery importa tion consumption or use of the Products sold hereunder including customs duties and sales excise use turnover and license taxes shall be charged to and remitted by Buyer to Omron Financial If the financial position of Buyer at any time becomes unsatisfactory to Omron Omron reserves the right to stop shipments or require satisfactory security or payment in advance If Buyer fails to make payment or otherwise comply with these Terms or any related agreement Omron may without liabil ity and in addition to other remedies cancel any unshipped portion of Prod ucts sold hereunder and stop any Products in transit until Buyer pays all amounts including amounts payable hereunder whether or not then due which are owing to it by Buyer Buyer shall in any event remain liable for all unpaid accounts Cancellation Etc Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses Force Majeure Omron shall not be liable for any de
20. lace Time Setting Ring B onto the time setting knob so that the stopper of Time Setting Ring B is on the left edge of the reset lock position of the Panel Cover Stopper Reset lock position c ots Time setting Time setting Panel cover ring B 6 Solid state Timer H3BA N OMRON E Timing Chart Note 1 The minimum power opening time Rt is 0 1 s and the minimum pulse width is 0 05 s 2 The letter t the timing charts stands for the set time and t a means that the period is less than the time set H3BA N Operating mode Timing chart A ON delay Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay NC 1 and 4 11 and 8 Output relay NO 1 and 3 11 and 9 and output indicator Power indicator B Flicker OFF start Power 2 and 10 Start Basic operation 2 and 6 Reset 2 and 7 Output relay NC 1 and 4 11 and 8 Output relay NO 1 and 3 11 and 9 and output indicator Power indicator B2 Flicker ON start Power 2 and 10 Start Basic operation 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator C Signal ON OFF delay Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator
21. lay or failure in delivery resulting from causes beyond its control including earthquakes fires floods strikes or other labor disputes shortage of labor or materials accidents to machinery acts of sabotage riots delay in or lack of transportation or the requirements of any government authority Shipping Delivery Unless otherwise expressly agreed in writing by Omron a Shipments shall be by a carrier selected by Omron Omron will not drop ship except in break down situations b Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer All sales and shipments of Products shall be FOB shipping point unless oth erwise stated in writing by Omron at which point title and risk of loss shall pass from Omron to Buyer provided that Omron shall retain a security inter est in the Products until the full purchase price is paid d Delivery and shipping dates are estimates only and e Omron will package Products as it deems proper for protection against nor mal handling and extra charges apply to special conditions Claims Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans portation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed Warranties a Exc
22. lusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS IMPLIED ABOUT NON INFRINGEMENT MERCHANTABIL 14 ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or oth erwise of any intellectual property right c Buyer Remedy Omron s sole obli gation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsi ble for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were prop erly handled stored installed and maintained and not subject to contamina tion abuse
23. misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Compa nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environ ments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Indemnities Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities losses claims costs and expenses including attorney s fees and expenses related to any claim inves tigation litigation or proceeding whether or not Omron is a party which arises or is alleged to arise from Buyer s acts or omissions under these Terms or in any way with respect to
24. olid state Timer H3BA N 19 Terms and Conditions of Sale OMRON 5 7 10 11 12 13 Offer Acceptance These terms and conditions these Terms are deemed part of all quotes agreements purchase orders acknowledgments price lists catalogs manuals brochures and other documents whether electronic or in writing relating to the sale of products or services collectively the Products by Omron Electronics LLC and its subsidiary companies Omron Omron objects to any terms or conditions proposed in Buyer s purchase order or other documents which are inconsistent with or in addition to these Terms Prices Payment Terms All prices stated are current subject to change with out notice by Omron Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders Payments for Products are due net 30 days unless otherwise stated in the invoice Discounts Cash discounts if any will apply only on the net amount of invoices sent to Buyer after deducting transportation charges taxes and duties and will be allowed only if i the invoice is paid according to Omron s payment terms and ii Buyer has no past due amounts Interest Omron at its option may charge Buyer 1 1 2 interest per month or the maximum legal rate whichever is less on any balance not paid within the stated terms Orders Omron will accept no order less than 200 net billing Governmental Approvals Buyer s
25. on to fall inside the Timer eoo B Precautions for Safe Use Please observe the following precautions for safe use of this product Environmental Precautions Store the Timer within specified ratings If the Timer has been stored at 10 C or lower let it stand for 3 hours or longer at room temperature before turning ON the power supply Use the Timer within the specified ratings for operating temperature and humidity Do not operate the Timer in locations subject to sudden or extreme changes in temperature or locations where high humidity may result in condensation Do not use the Timer in locations subject to excessive dust corrosive gas or direct sunlight Do not use the Timer in locations subject to vibration or shock Extended use in such locations may result in damage due to stress Install the Timer well away from any sources of static electricity such as pipes transporting molding materials powders or liquids Usage Precautions Install a switch or circuit breaker that allows the operator to immediately turn OFF the power and label it to clearly indicate its function Pay careful attention to polarity to prevent wrong connections when wiring terminals Internal elements may be destroyed if a voltage outside the rated voltage is applied Maintain voltage fluctuations in the power supply within the specified range The Timer uses a transformerless power supply Do not touch the input terminals while th
26. rface with screws and insert the F shaped hook into the sockets by hand Panel Mounting When the Y92F 30 Flush Mounting Adapter is used insert the Timer into the square hole from the front side of the panel and put on the Flush Mounting Adapter from the rear side of the Timer Press the Flush Mounting Adapter so that the space between the Flush Mounting Adapter and the panel is reduced as much as possible and secure the Flush Mounting Adapter with screws Panel Y92F 30 When using the USOS be sure to use 10 5 dia max multi conductor cable or 3 dia max insulated stranded wire for wiring When the Y92F 40 Y92F 70 or Y92F 71 Flush Mounting Adapter is used just insert the Timer into the square panel hole If the panel coating is too thick and the hooks do not click spread open the hooks appropriately to the left and right after inserting the Timer to the hole Spread open the hooks to the left and right Panel The illustration is an ex ample with the Y92F 70 Spread open the hooks to the left and right OMRON Dismounting Surface Mounting with P2CF Panel Mounting Loosen the screws of the Flush Mounting Adapter spread open the hooks and remove the Mounting Adapter When the Y92F 40 Y92F 70 Y92F 71 Mounting Adapter is used press the hook inwards with the thumb and index finger of both hands and press the Timer towards the front side 18 Solid state Timer H3BA N OMRON S
27. single amplitude each in three directions Malfunction 10 to 55 Hz with 0 5 mm single amplitude each in three directions Shock resistance Destruction 1 000 m s approx 100G each in three directions Malfunction 100 m s approx 10G each in three directions Ambient temperature Operating 10 C to 55 C with no icing Storage 25 C to 65 C with no icing Ambient humidity Operating 3596 to 8596 Life expectancy Mechanical 20 million operations min under no load Mechanical 10 million operations min under no at 1 800 operations h load at 1 800 operations h Electrical 100 000 operations min 5 A at 250 VAC Electrical 100 000 operations 5 A at 250 resistive load at 1 800 operations h VAC resistive load at 360 operations h Light gray Munsell 5 7 Enclosure ratings IEC IP40 panel surface Weight sg Note For setting the time limit of the Timer to a cycle of less than 3 seconds or applying the forced reset use the H3BA N in mode D signal OFF delay Nomenclature H3BA N H3BA N8H Power Indicator Green Operating Mode Display Window Power Indicator Green Output Type Display Window Lit when Timer operates Lit when Timer operates i o Output Indicator Orange B Lit when Timer outputs Output Type Selector Select a type from A and H A Time limit DPDT UP er default setting Output Indicator Orange 9 i ge H
28. t B2 Flicker ON start C Signal ON OFF delay D Signal OFF delay E Interval input type No voliage Output type DPDT time limit SPDT time limit and switchable SPDT time limit lt gt instantaneous Mounting method DIN track mounting surface mounting and flush mounting Approved standards UL508 CSA C22 2 No 14 Conforms to LR currently under application and approval is expected by the end of Feb 2006 Time Ranges s amp e mm hw paon O o oe O Ratings H3BAN _____________ Rated supply voltage 110 VAC 50 60 Hz 220 VAC 50 60 Hz 24 VDC See notes 1 and 2 Operating voltage range 8596 to 110 of rated supply voltage See note 3 Minimum power opening time 0 1 s No voltage input ON impedance 1 ON residual voltage 1 V max OFF impedance 200 min Power consumption 110 VAC Approx 4 6 VA 1 5 W 110 VAC Approx 3 6 VA 1 6 W 220 VAC Approx 7 9 VA 1 3 W 220 VAC Approx 5 4 VA 1 4 W 24 VDC Approx 0 6 W 24 VDC Approx 0 9 W Control outputs Contact 5 A at 250 VAC resistance load cos 1 Note 1 DC ripple rate 20 max 2 Models other than 24 VDC H3BA N models cause an inrush current Pay careful attention when attempting to turn on power to such models with non contact output from a device such as a sensor 3 90 or higher if
29. the Products Without limiting the foregoing Buyer at its own expense shall indemnify and hold harmless Omron and defend or set tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party Property Confidentiality Any intellectual property in the Products is the exclu sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron Notwithstanding any charges to Buyer for engineering or tooling all engineering and tooling shall remain the exclusive property of Omron All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party Export Controls Buyer shall comply with all applicable laws regulations and licenses regarding i export of products or information iii sale of products to forbidden or other proscribed persons and ii disclosure to non citizens of regulated technology or information Miscellaneous a Waiver No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron b Assignment Buyer may not assign its rights hereunder without Omron s written consent c Law
30. vided as a guide for the user in determining suitabil ity and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application require ments Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our prac tice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifica tions of the Product may be changed without any notice When in doubt spe cial part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions Note This datasheet is provided as a guideline for selecting products Do not use this document to operate the Unit ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 OMRON OMRON ELECTRONICS LLC e THE AMERICAS HEADQUARTERS Schaumburg IL USA