1. 0 1785 813748 e mail techne barloworldscientific com www barloworldscientific com Barloworld Scientific Barloworld Scientific Ltd Beacon Road Stone Staffordshire ST15 OSA United Kingdom Tel 44 0 1785 812121 Fax 44 0 1785 813748 www barloworld scientific com Barloworld Scientific France Ltd BP 79 77793 Nemours Cedex France Tel 33 1 64 45 13 13 Fax 33 1 64 45 13 00 e mail bibby bibby sterilin fr Techne Inc 3 Terri Lane Suite 10 Burlington NJ 08016 United States Tel toll free 800 225 9243 Fax 609 589 2571 e mail labproducts techneusa com www techneusa com Barloworld Scientific Italia Ltd Via Alcide de Gasperi 56 20077 Riozzo Di Cerro Al Lambro Milano Italy Tel 392 983 8969 Fax 392 982 30211 www bibby sterilin it Afora S A Calle Aribau 240 08006 Barcelona Spain Tel 343 93 306 98 00 Fax 343 93 306 98 23 e mail marketing afora com www afora com
2. connected to the instrument BEFORE connection to the mains supply Should the mains lead need replacement a cable of 0 5mm to BS6500 amp CENELEC HD21 5 should be used IF INDOUBT CONSULT A QUALIFIED ELECTRICIAN 4 2 Touse the Gelation Timer mount the instrument clamping post onto a suitable retort stand or fixture at the desired height for operation Ensure that the instrument is clamped firmly 4 3 Screw the appropriate paddle to the end of the paddle connector on the sliding contact 4 4 Connect the instrument to the electricity supply and switch on 4 5 The instrument will perform an automatic self test at switch on All segments will illuminate momentarily before displaying a single zero on the right hand side a buzzer will sound and the LED should illuminate green The gelation timer is now ready to use 5 Operation DISPLAY START amp RESTART LED BUTTON HOLD amp STOP BUTTON 5 1 Sample preparation The test requires about 100ml of sample in a container at least 38mm internal diameter The top of the paddle stroke should be not less than 32mm below the sample surface and the bottom of stroke not closer than 13mm to the bottom of the container Standard sample cups for use with the instrument are available catalogue number F7846 5 2 Starting Gelation Having prepared the sample in the manner described gelation time measurement can be started in one of the following ways 5 2 1 If
3. restarted from when it was stopped therefore the elapsed time between stopping and restarting the timer is not recorded 5 4 Stopping during gelation measurement The instrument can be stopped during gelation by pressing the Stop button once The paddle stops reciprocating the LED is extinguished and the word STOP is indicated on the display To restart the gelation process just press the Restart button once Note While in stop mode the timer will continue to run and when restarted will indicate actual gelation time However if the Stop button is pressed a second time having just stopped it the timer will reset and the instrument will enter the Hold state see 5 2 2 above 6 Maintenance Servicing amp Repair WARNING Ensure the unit is disconnected from the mains electricity supply before attempting maintenance or servicing This range of equipment does not require routine servicing The only maintenance required is to clean external surfaces with a damp cloth and mild detergent Spillages or splashes should be cleaned up straightaway after isolating the unit from the mains electricity supply 6 1 Repairs Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel Only spare parts supplied or specified by Barloworld Scientific Ltd or its agent should be used Fitting of non approved parts may affect the performance of the safety features designed into the instrument
4. you want to set up your sample under the paddle start reaction and gelation timer simultaneously Press the start button once This starts the timer incrementing the LED will flash Green and the paddle will start to reciprocate up and down When the sample has gelated to the extent that paddle movement is halted circuit is closed the timer is stopped along with the paddle the buzzer sounds and the display will alternate between the word GEL and the indicated gelation time This is the normal gelation mode 5 2 2 Alternatively if you want to start the timer as soon as the sample reaction is started Press the Hold button once as soon as the sample is mixed the timer starts incrementing as gelation has started the LED will illuminate Red the paddle will reciprocate up and down and the display will alternate between the word HOLD and accumulated time If the paddle switch is closed in the HOLD state the timer is not stopped and the paddle continues to reciprocate This allows you time to place the sample under the paddle and get ready for gelation measurement To commence gelation measurement once everything is set up just press Start button once and then follow instructions shown above in 5 2 1 5 3 Accidental tripping during gelation measurement If the paddle is accidentally tripped during gelation the timer can be restarted by pressing Restart button once Note that the timer is
5. FGTS amp FGT6 Gelation Timer Instructions for use Barloworld Scientific CLAMPING BAR PADDLE CONNECTOR PADDLE 1 Introduction Thank you for purchasing this piece of Techne equipment To get the best performance from the equipment please read these instructions carefully before use For your own safety and that of others please read and understand the safety advice given below before using the equipment Before discarding the packaging check that all parts are present and correct 2 Safety Advice before use If the equipment is not used in the manner described in this manual and with accessories other than A those recommended by Barloworld Scientific the protection provided might be impaired This equipment is designed to operate under the following conditions _ For indoor use only _Use in a well ventilated area Ambient temperature range 5 C to 40 C Altitude to 2000m Relative humidity not exceeding 80 _Mains supply fluctuation not exceeding 10 Over voltage category II IEC60364 4 443 Pollution degree 2 Use with a minimum distance all around of 200mm from walls or other items The unit should be carried using both hands Do not use in a hazardous atmospheres or with hazardous materials Never move or carry the unit when in use or connected to the mains electricity supply In the case of mains interruption the unit will not restart on restoration of the electricity supply In
6. For a comprehensive list of parts required by service engineers conducting internal repairs or to receive a service manual please contact the Sales Department of Barloworld Scientific Ltd quoting both the model and serial number If in any doubt please contact the Service Department of Barloworld Scientific Ltd 6 2 Calibration Your Gelation Timer has been carefully factory calibrated and is provided with a calibration certificate If you require your unit to be re calibrated at any time please contact our Service Department of Barloworld Scientific Ltd 6 3 Accessories A range of accessories detailed below is available for use with the Gelation Timer Description Catalog Number Code 22mm Stainless Steel Plunger 6020985 F0985 19mm Stainless Steel Plunger 6020979 F0979 7 Warranty Barloworld Scientific Ltd warrants this instrument to be free from defects in material and workmanship when used under normal laboratory conditions for a period of three 3 years In the event of a justified claim Barloworld Scientific will replace any defective component or replace the unit free of charge This warranty does NOT apply if damage is caused by fire accident misuse neglect incorrect adjustment or repair damage caused by installation adaptation modification fitting of non approved parts or repair by unauthorized personnel Barloworld Scientific Ltd Stone Staffordshire ST15 OSA United Kingdom Tel 44 0 1785 812121 Fax 44
7. the case of mains interruption the unit will reset on restoration of the electricity supply 3 General Description The Techne Gelation Timer is the ideal instrument for accurate measurement and quality control for the gelation of resin or adhesive based samples in the laboratory Before leaving the factory each instrument is calibrated and certificated All models have digital timers with the output time in 1 minute increments up to 9999 minutes for the 1 RPM model GT5 and in tenths of a minute up to 999 9 minutes for the 10 RPM model GT6 Accuracy of indicated gelation time is 2 at a specific temperature 4 Preparation for Use All models 4 1 Electrical Installation THIS INSTRUMENT MUST BE EARTHED Before connection please read and understand these instructions and ensure that the line supply corresponds to that shown on the rating plate Voltage variants for these instruments are 230V 50Hz 230V 60Hz 120V 50Hz amp 120V 60Hz The power consumption of each unit is 5W This unit is supplied with a mains lead which requires a rewirable mains plug to be fitted IT IS IMPORTANT THAT THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN NOTE Refer to the equipment s rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated The wires in the mains cable are coloured as follows LIVE BROWN NEUTRAL BLUE EARTH GREEN YELLOW The appropriate mains plug should be