Home
Chief MIWRF6000B flat panel wall mount
Contents
1. Regolare Afstellen Ajuster Installation Instructions MIWRF SERIES TOOLS REQUIRED FOR INSTALLATION AND PARTS a 1 8 7 16 9 16 1 ga NOTE O Listed MSBU interface bracket provided with Listed Model MIWRFUB but not shown A Listed MSBV interface bracket provided with Listed Model MIWRFVB but not shown e 5 16 x 2 1 2 5 16 4 B 2 C 4 we D 4 S E 2 U F 1 G 2 eh L 4 gl K 4 Po 8 5 16 18 Figure 1 MIWRF SERIES Installation Instructions INSTALLATION WARNING IMPROPER INSTALLATION CAN RESULT IN DEATH OR SERIOUS PERSONAL INJURY This accessory should be installed by qualified personnel only WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT DO NOT deviate from installation instructions provided DO NOT substitute hardware The MIWRF Series is designed to accommodate up to 3 1 2 of lateral shift adjustment right or left display offset from center of studs This is accomplished by aligning the upper and lower mounting studs on the housing with either the right hand or left hand mounting holes in the upper and lower mounting brackets See Figure 3 IMPORTANT Using the lateral shift feature will impact the location of the Listed J Box not included installatio
2. FPA 70 1999 Refer to communication equipment manufacturer s specifications for minimum spacings MIWRF Series contains the following models e MIWRF e MIWRFUB e MIWRFVB MIWRF SERIES Installation Instructions DIMENSIONS F 20 34 pa o oUo o o O o EI 17 20 I 13 38 8 95 1 0 HEIGHT ADJUST T 1 67 ADDED DEPTH ag i A S J ob D Gi p 14 38 14 96 WL Gi 1 LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations 4 Open Ended Wrench Llave de boca Gabelschlussel Chave de bocas Chiave a punte aperte Steeksleutel Cl a fourche Adjust Ajustar Einstellen Ajustar
3. INSTALLATION INSTRUCTIONS Medium Flat Panel In Wall Mount CHIEF MIWRF SERIES Our Mounts Your Vision MIWRF SERIES Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief and ClickConnect are trademarks of Milestone AV Technologies All rights reserved A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury dama
4. covers E and sliding tabs in until end caps D are flush with wall channel covers E See Figure 8 Figure 8 MIWRF SERIES Installation Instructions Trim Installation To install optional trim 1 Orient two trim pieces G See Figure 9 2 Slide slat in trim edge over lip in mount enclosure and press trim G onto enclosure See Figure 9 Figure 9 Display Installation WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT DO NOT install display in a manner other than that specified by the manufacturer Certain displays may require the use of an interface bracket for proper installation of the display If an interface bracket is not installed or there are any other questions regarding the installation of the display immediately contact a Chief Customer Service representative WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT Displays can weigh in excess of 40 Ibs 18 1kg ALWAYS use two people and proper lifting techniques when installing display WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT Make sure mounting buttons on display are properly
5. ge to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for the installation of this kit can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this kit is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to this accessory does not exceed 125 Ibs 57 kg SUITABLE FOR USE IN OTHER ENVIRONMENTAL AIR SPACE IN ACCORDANCE WITH SECTION 300 22 C OF THE NATIONAL ELECTRICAL CODE The equipment shall be installed and assembled by qualified service personnel The maximum specified ambient temperature of the cabinet system is 40 120 F 4 49 Minimum spacings between the accessories and components and the housing for Information Technology Communication Equipment shall be maintained for safe operation of the equipment when installed in accordance with the National Electric Code ANSI N
6. ged nuts K See Figure 3 and See Figure 4 Figure 4 7 Install Listed J box s not included and route all in wall cables and wiring to mount enclosure keeping in mind the lateral shift offset determined during Step 3 above See Figure 3 WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT Wiring of equipment must be performed by properly trained and certified persons following all applicable codes 8 Slide mount A enclosure into opening in wall See Figure 5 A x 1 Figure 5 9 Place spacers C provided between wall and upper and lower mounting rails B if required See Figure 6 Figure 6 10 Secure mount to studs using four flat washers F2 and four lag screws F1 See Figure 7 MIWRF SERIES Installation Instructions Cover and Trim Installation Cover Installation To install covers O F1 x4 F2 x 4 1 Install upper and lower wall channel covers E by tipping cover top down and positioning as shown in end view of figure below See Figure 8 2 Tap firmly across bottom of channels to lock in place as shown in figure below See Figure 8 3 Install four R H and L H end caps D by aligning tabs on end caps D with slots in wall channel
7. ide See Figure 14 Check for desired tension 1 Locate and install cable tie clips J where desired for proper 3 Repeat Steps 1 and 2 until desired tension is obtained cable routing See Figure 12 points o Figure 12 2 Route cables down arms on mount See Figure 13 3 Position cable covers L over arm and cable and press cable covers L down onto arms to secure cables See Figure 13 WARNING IMPROPER INSTALLATION CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT DO NOT route cables through holes in faceplate Figure 14 Roll Adjustment The mount allows for the horizontal alignment Roll of the display to be adjusted up to 2 right or left to level the display after installing To adjust Roll 1 Loosen the roll tension adjustment nut located on the back side of the faceplate assembly See Figure 15 2 Level display NOTE If display will not level slightly loosen top nut as well 3 Tighten roll tension adjustment nut See Figure 15 From Display Figure 13 MIWRF SERIES Installation Instructions Figure 15 Extend Retract Tension Adjustment Arm Extend and Retract tension is pre set at the factory and is adjusted to accommodate displays with weights near the top of the mounts capacity If smaller displays are used it may be difficult to repositi
8. n on the housing If housing lateral shift is used any Listed J box must be installed to the side opposite the direction of adjustment 1 2 3 4 Determine desired mounting location and locate studs using a stud finder or similar method Accurately locate center of studs Determine desired lateral shift required See Figure 3 Using a level mark housing opening location on wall using the dimensions identified See Figure 2 Cutout Area Figure 2 Upper Mounting Bracket Lower Mounting Bracket Figure 3 MIWRF SERIES Installation Instructions WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of gas water waste or any other plumbing before cutting drilling or installing fasteners 5 Cut drywall on outside edge of lines and remove 6 Assemble upper and lower mounting rails B to mount A in slots that correspond to the desired lateral shift offset identified during step 3 above using four flan
9. on the display after mounting Arm Extend and Retract tension can be adjusted to compensate for smaller display The display must be mounted prior to adjusting swing arm tension 1 With display installed tighten or loosen adjustment screw using hex wrench See Figure 16 2 Check for desired tension 3 Repeat Steps 1 and 2 until desired tension is obtained NOTE If changing from a smaller display to a larger display it may be necessary to increase tension 10 on back side in this view Di Figure 16 Display Height Adjustment The mount is designed to accommodate up to 1 of display height adjustment e Bn To adjust display height 1 With display installed loosen adjustment locking screw using hex wrench See Figure 17 2 Adjust display height by turning adjustment nut in desired direction See Figure 17 3 Tighten adjustment locking screw when display is at desired height See Figure 17 Figure 17 Installation Instructions MIWRF SERIES YAW Tension Adjustment The mount is designed to accommodate up to 37 5 of travel to left and right of center To adjust YAW tension 1 With display installed loosen adjustment screw using hex wrench See Figure 18 2 Check for desired tension 3 Repeat Steps 1 and 2 until desired tension is obtained NOTE If changing from a smaller display to a larger display it ma
10. seated in mounting holes in faceplate 1 Install Listed interface bracket following the installation instructions provided with the interface bracket 2 Move mount faceplate to extended position by grasping faceplate and pulling outward away from wall See Figure 10 3 While supporting both sides of display align four mounting buttons on display or interface bracket with four mounting holes in faceplate See Figure 10 4 Lower display into place listening for audible click to ensure recessed area of mounting buttons are properly seated in lower area of mounting holes and click lock mechanism has engaged See Figure 10 and See Figure 11 Figure 10 NOTE Holes are provided in the faceplate for use with a padlock or similar locking device if desired In addition the pin and nut may be removed from the upper holes and moved to the lower holes for use as a more permanent locking device See Figure 11 and nuts and move to lower holes A padlock or bolt may be placed through latch holes Figure 11 Installation Instructions MIWRF SERIES CABLE MANAGEMENT ADJUSTMENTS Pitch Tension Adjustment WARNING IMPROPER INSTALLATION CAN LEAD TO To adjust display pitch tension SERIOUS PERSONAL INJURY OR DAMAGE TO aa EQUIPMENT Make sure cables do not run through pinch 1 With display installed tighten or loosen two screws one on each s
11. y be necessary to increase tension EACH DIRECTION Figure 18 11 MIWRF SERIES Installation Instructions O CH E F USA International Our Mounts Your Vision F ae Europe Chief Manufacturing a products division of Milestone AV Technologies Asia Pacific 8805 000249 RevB 2009 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 11 09 Pn 0 Pn 0 P TU 8401 Eagle Creek Parkway Savage MN 55378 800 582 6480 952 894 6280 877 894 6918 952 894 6918 Fellenoord 130 5611 ZB EINDHOVEN The Netherlands 31 0 40 2668620 31 0 40 2668615 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 7 S em d O o roowauggf
Download Pdf Manuals
Related Search
Related Contents
MDF - Musiques et Danses en Finistère Manuales sistema ultravioleta UV CA-SERIES - Home Depot Manuel de l'utilisateur User Manual Benutzerhandbuch Bedienstation M3i Utilitaire de contrôle LAN Manuel d`utilisation TARIFS ET DATES - CERCLE PHILATELIQUE FRANCE RUSSIE et commune de beaulieu-les-loches cahier des clauses techniques Copyright © All rights reserved.
Failed to retrieve file