1. allel RRA SD16A Instruction Manual 8 Specification Display Digital display Measured value PV 7 segment Red 4 digit LED Action indication SET green _ lit when parameter value is displayed COM green lit when communication mode is set AL1 AL2 red lit when alarm signal is output Analog output type 0 10mV Output resistance 100 0 10V Load current 1mA max 4 20mA Load resistance 300Q max Output resolution Approx 1 14000 Display accuracy 0 3 FS 1 digit within measuring range Excluding cold junction temperature compensation accuracy of thermocouple input 5 FS for temperature below 400 C 752 F of thermocouple B Accuracy of thermocouple T or U is 0 5 FS at above 100 C and 0 C or below and 1 FS at 100 C or below Display accuracy maintaining range 23 C 5 C 18 28 C Display resolution Differs depending on the measuring range 0 001 0 01 0 1 1 Measured value 10 110 of measuring range Accuracy is only guaranteed display range when the value is within the measuring range For R T D input of 199 9 600 0 C 240 0 680 0 C 199 9 500 0 C 240 0 570 0 C For thermocouple K of 199 9 800 0 C 273 1 900 0 C Display update cycle 0 25 5 00 secs 0 25 secs step When 0 50 secs or more is set a difference may occur among the displayed value the analog output and the communi
2. AN CAUTION To avoid damage to the connected equipment facilities or the product itself due to a fault of the product safety countermeasure must be taken before usage such as proper installation of the fuse and the overheating protection device e An alert symbol A is printed on the terminal nameplate attached to the case It warns not to touch the electrical charging parts when the power is being supplied so as to avoid the risk of electrical shock e Install a switch or breaker on the external source power circuit connecting to the source power terminal as a means to shut down the power The switch or breaker should be installed adjacent to the instrument in a position that allows the operator easy access e Regarding the fuse Since this instrument has no built in fuse make sure to install a fuse in the electric circuit connecting to the source power terminal Install the fuse in a position between the switch or breaker and the instrument and attach it to the L side of the source power terminal Fuse Rating 250V AC 1 0A Time lag T or Medium Time lag M e The load of voltage and current to be applied to the output terminal analog output and the alarm terminal must be within the rated range If the range is exceeded the instrument will overheat causing the risk of the instrument being damaged and its life reduced As for the rating please refer to 8 Specification The unit connected to the output terminal should conform
3. Alarm setting value Hysterisis PV measured value ON i ON Alarm signal OFF OFF Time gt The latching feature is enabled Release of latching Not allowed Allowed Not allowed Allowed j Operation of latching release Alarm action region Alarm H setting value PV measured value ON Alarm signal OFF Time 7 2 Analog output Analog output is a feature that outputs PV value based analog voltage or analog current By setting the analog output scaling lower limit value screen 1 15 or higher limit value 1 16 the analog output signal can be gained by PV value base within a specified measuring range Ao_L lt Ao_H Ao_L gt Ao_H reverse scaling 100 100 F Analog output 0 i 0 H i Ao L Ao_H Ao_H Ao_L lt gt Measuring range Measuring range 7 3 Sensor power supply In case the optional DC sensor power supply 24V DC 25mA is selected the instrument can be used with the Humidity Sensor H71 TH71 series Note that if 08 of power 24V AC DC from type code is selected the sensor power supply cannot be specified iring example using with Humidity Sensor H71 TH71 For voltage V Input For current mA Input 24V DC 25mA v p 5 H71 TH71 Ta ma H71 TH71 h a E fs naj 19 tr IN OUT iole leee SD16A 6A oboleo bebbe
4. R nnnn n nnn Ini n n 1 7__Input scaling lower limit value The scaling lower limit value for voltage current mV Lah input is displayed or can be set V mA Other than voltage current input display only Note The span between lower limit and higher limit is 10 10000 Reverse scaling is available R 1999 9999 Unit Ini 0 Unit 1 8 Input scaling higher limit value The scaling higher limit value for voltage current mV En_H y input is displayed or can be set Other than voltage current input display only Note The span between the lower limit and the higher limit is 10 10000 Reverse scaling is available R 1999 9999 Unit Ini 1000 Unit 1 9 Alarm 1 code zi The Alarm 1 action type is displayed or can be AL I mun 1 set As for action types refer to Action type of 7 1 Alarm output non none HA Higher limit absolute value LA Lower limit absolute value HA_L Higher limit absolute value with latching LA_L Lower limit absolute value with latching So Scale over Note Once the alarm code is changed the preset values are initialized However they are not initialized when the code is changed HA lt gt HA_L or LA lt gt LA_L R non HA LA HA_L LA_L So Ini HA 1 10 Alarm 1 hysterisis The Alarm 1 hysterisis is displayed or can be set AL This screen is not displayed when non or So scale over is selected on the Alarm 1 code screen 1
5. 199 9 300 0 300 600 Note 3 L 11 0 600 0 1100 p WRe5 26 12 0 2300 0 4200 2 Pt 31 199 9 600 0 300 1100 Note 4 a 32 100 0 100 0 150 0 200 0 JPt 33 199 9 500 0 300 1000 Note 4 34 100 0 100 0 150 0 200 0 0 10mV 71 gp Orv 81 0 0 100 0 Scaling available 1 5V 82 __ Scaling range 1999 9999 Unit 0 10V 83 Span 10 10000 Unit Current 4 20MA 95 Note 1 In case universal input type is selected K Code 05 0 1200 C is set at factory default Note2 The accuracy of 400 C or below of thermocouple B is 5 FS Note 3 The accuracy of thermocouple T or U is 0 5 FS at above 100 C and 0 C or below and 1 FS at 100 C or below Note4 In case of Pt Code 31 or JPt Code 33 scale over occurs at 240 0 C 400 F 5 Error messages One of the following error messages is displayed on the basic screen 0 0 When the thermocouple or A of R T D is burnt out Also indicated when the PV value exceeds the higher limit of the measuring range by about 10 HHHH When the B of R T D terminal No 7 is burnt out When the PV value is below the lower limit of the measuring range by about 10 for such a reason as the reverse polarity of the input wiring type HH When the cold junction CJ is abnormal on the higher 4 side in the thermocouple input When the cold junction CJ is abnormal on the lower side in the thermocouple input When the B of the R T D terminal
6. 4 Decimal places This screen is displayed in case Alarm 2 code 1 12 The decimal place with without status is is selected from the one with latching and when the displayed or can be set instrument is in the latching state Set the parameter dp_y with decimal places at RSET to stop the alarm output dp_n without decimal places As for the latching feature refer to Latching feature In case the measuring range that doesn t support decimal places is specified of 7 1 Alarm output this screen is not displayed KEEP Alarm output is ON with latching feature Once this setting is modified from with decimal places to without decimal RSET Releasing the alarm with latching feature Note places the values of input scaling analog output scaling alarm setting alarm hysterisis and PV bias are rounded to the nearest integer Then that Note The Alarm 2 output signal with latching feature can also be set to OFF by setting is modified to with decimal places again the value after the decimal pressing key on the Basic screen 0 0 places remains 0 R KEEP RSET Ini KEEP R ap_y dp_n Ini dp_y SD16A Instruction Manual 1 5 Input unit me link R C F The input unit is displayed or can be set ni c 1 6__Input scaling decimal places The scaling decimal places for voltage current mV system input are displayed or can be set V mA Note Other than voltage current system input display only
7. be set R 1 100 Ini 1 l The communication data format is displayed or ce JAER can be set The setting value is composed of three alphanumerical characters Left character Data length bits 7 or 8 Middle character Parity E even or N none Right character Stop bit 1 or 2 For MODBUS ASCIl specify one of the 7 bit format types The default value is 7E1 For MODBUS RTU specify one of the 8 bit format types The default value is 8E1 R 7E1 7E2 7N1 7N2 8E1 8E2 8N1 8N2 fini 7E1 Note 1 21 Communication start character ir Lg 1 The start character of communication data is D 5 c h A displayed or can be set STX Start character STX 02H Text end ETX 03H End character CR 0DH ATT Start character 40H Text end 3AH End character CR 0DH Note MODBUS ASCII RTU doesn t use a start character R STX ATT Ini STX 1 22 Communication BCC operation n The BCC operation method is displayed or can be set Co l 5 cc L 1 ADD operation from the start character to the text end character 2 2 s complement after ADD operation from the start character to the text end character 3 XOR operation from after the start character to the text end character 4 BCC operation is not performed Note MODBUS ASCII RTU doesn t use BCC R 1 4 Ini 1 1 23 Communication speed l The communication speed is displayed or can be i b P 5 set Note In case of 19
8. 200 bps 1920 is displayed on the screen R 1200 2400 4800 9600 19200 bps Ini 9600 Analog output 1 24 Communication dela i ru i The delay time by communication between time 1 det 4 I of receiving a command and sending the reply is displayed or can be set R 1 100 msec Ini 20 ee ree 7 Optional features overview 7 1 Alarm output The instrument supports two points of alarm optionally Action type The following alarm output action types screen 1 9 or 1 12 are supported The lower limit absolute value alarm The higher limit absolute value alarm ON j a ON 0 fA OFF 100 0 OFF f 100 Alarm setting value Alarm setting value Scale over ON ON Alarm OFF OFF 10 0 100 110 SD16A Instruction Manual Inhibit action When the alarm output inhibit action is set to ON on screen 1 11 or 1 14 the inhibit action at power on is performed as follows PV measured value Alarm setting value Hysterisis i Alarm standby gt Alarm signal j ON Power ON Time Latching feature The latching feature outputs the alarm signal constantly once PV is detected in the alarm action region even if PV is out of the alarm action region later When PV is in the alarm action region latching cannot be released To release the latching refer to the description of screen 0 0 0 1 or 0 2 The latching feature is disabled Alarm action region
9. 9 Ini 20 Unit R 1 999 Unit Note 1 11 Alarm 1 inhibit The Alarm 1 inhibit status is displayed or can be Q it tly set This screen is not displayed when non or So scale over is selected on the Alarm 1 code screen 1 9 Ini OFF R OFF oN Note 1 12 Alarm 2 code Trege The Alarm 2 action type is displayed or can be AL i Ae ny set As for action types refer to Action type of 7 1 Alarm output non none HA _ Higher limit absolute value LA _ Lower limit absolute value HA_L Higher limit absolute value with latching LA_L Lower limit absolute value with latching So Scale over Once the alarm code is changed the preset values are initialized However they are not initialized when the code is changed HA lt gt HA_L or LA lt gt LA_L R non HA LA HA_L LA_L So Ini LA Note 1 13 Alarm 2 hysterisis l 1 The Alarm 2 hysterisis is displayed or can be set Hed This screen is not displayed when non or So scale over is selected on the Alarm 2 code screen 1 12 Ini 20 Unit R 1 999 Unit Note 1 14 Alarm 2 inhibit VoD a The Alarm 2 inhibit status is displayed or can be AL fad Pad I h i set This screen is not displayed when non or So scale over is selected on the Alarm 2 code screen 1 12 Ini OFF R OFF ON Note 1 15 Analog output scaling lower limit value The analog output s
10. Digital Indicator SD16A Series Instruction Manual c aC ae EJEJ SHIMADEN Please ensure that this instruction manual is given to the final user of the instrument Thank you for purchasing Shimaden products Please check that the delivered product is the correct item that you ordered This instruction manual is meant for those who will be involved in the wiring installation operation and routine maintenance of the SD16A series and describes about cautions mounting wiring functions and operation Please observe the contents and always keep the manual close at hand when handling this instrument The following headings give a description of matters requiring user attention concerning safety damage to machines and equipment additional explanations and commentaries are described under the following headings Items concerning matters that may lead to an accident producing human injury or death if the warning is not observed Items concerning matters that may lead to AN WARNING an accident producing damage to machines A CAUTION or equipment if the caution is neglected E Additional explanations and commentaries Preface eena a dni A a a A Aaaa 1 COMENS aaeeea A r N A A 1 Safety CAU ON Scio eaa a eaa raa aa a iiaa 1 A JUIMMOGUCUON esea ia EEEE EEE E E EEA 1 1 Check before use 1 2 Notes for use 2 Installation and WITING esisiini aaa aaia aa 2 2 1
11. Group 0 3_PV bias The following information is displayed automatically The PV bias value is displayed or can be set The value is used for compensating input errors by Model name the sensor etc When the value is set the The model name SD16A is displayed compensated Py isidigplayed R 1999 2000 Unit Ini 0 Unit EEEa 0 4 PV filter The input type is displayed The PV filter time is displayed or can be set The type is either TC thermocouple Pt R T D mV V or mA The value is helpful for reducing the adverse effect of noise from a PV input The PV filtering is temporarily disabled when the instrument is recovering from scale over Note Measuring range lower limit value The lower limit value of the input is displayed R 0 100 seconds Ini 100 0 5 Alarm1 setting value 7 7 a lo tue Alarm 1 setting value is displayed or can be set AL Measuring range higher limit value I A I HA I One of the following Alarm 1 action types 1 9 is displayed on the screen A P ot A1HA Higher limit absolute value The higher limit value of input is displayed AILA Loweclinitabeolute valie A1H A Higher limit absolute value with latching A1L A Lower limit absolute value with latching This screen is not displayed when non or So scale over is selected on 6 3 Mode 0 Screen Group Note Alarm 1 code screen 1 9 The following informational icons ar
12. Installation site environmental Conditions eceeeeeeeee 2 2 2 Mounting 2 3 External dimensions and panel cutout 2A WINN irah e E ESAE 2 2 5 Terminal arrangement cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeenee 3 ad 3 2 Functions 4 Measuring range code table eecceeeseeceeeeeeeeeeeeeneeeeeeeeteeeseeeeeeeee 3 5 Error MESSaHE Sirenian crina ca a a a aaar aa eaaa 3 6 Instruction for each screen 6 1 Screen sequences 6 2 Power ON Screen Group 6 3 Mode 0 Screen Group 6 4 Mode 1 Screen Group aissein idasi diiine aeiiae 5 7 Optional features Overview seeeseeeeeeeeeeeeenteeeeereerneseenrennennnsre neeme 7 7 1 Alarm output 7 2 Analog output A 7 3 Sensor power supply Bi SPOCiiCati On oe ceeceaceceee sv cev end e EEE EE AEAEE 8 MSD16A E01 A May 2006 Safety Cautions A WARNING The SD16A Series indicator is designed to indicate temperature humidity and other physical data for general industrial equipment Do not apply this instrument to other objects in a way that may cause grave effects on human safety e In using this product be certain to house it for example in a control panel so that the terminals cannot come into contact with personnel e Do not take this instrument out of its case or put your hand or any conductor inside the case Such conduct may lead to an accident that endangers life or causes serious injury due to electric shock
13. No 9 is burnt out or two or more wires of A B B are broken SD16A Instruction Manual 6 Instruction for each screen 6 1 Screen sequences Power ON Mode 0 Mode 1 Screen Group Screen Group O Screen Group 0 i Model name Basic screen For approx two secs Input type OO Alarm 1 Key lock latching release Measuring range DOO lower limit value Alarm 2 Display latching release update cycle Measuring range higher limit value OO PV bias Measuring range O PV filter Decimal places D O Alarm 1 Input unit setting value l D O Alarm2 i Input scaling setting value AcLA Tag Di decimal places w 28 D C to A Basic screen Input scaling lower limit value DOL Each screen is classified by the screen frame as follows ___ Input scaling higher limit value Screens always displayed DO Screens displayed or not displayed Alarm depending on some conditions Screens displayed when any option is added aE L hysterisis Key operations on screens of Power ON Screen Group a Sete hig pe era ce Te en raat eee arm No key operation is required as screens alter automatically inhibit within Power ON Screen Group DO Alarm 2 Key operations on screens of Mode 0 Screen Group code Mode 0 Screen Group consists of screens that are often used under a J control operation The commonly used key operations are as follows hysterisis Shifting a display screen to th
14. amage or discrepancy Confirmation of the type code Check the type code printed on the label on the packing case with the following table to confirm that the delivered goods meet your order Item Code Specifications 1 Series SD16A 48 x 96 DIN size Digital Indicator Universal input Thermocouple R T D Pt100 JPt100 Voltage Input impedance Refer to 4 Measuring range code table for details In case voltage input o 500 kQ min scaling reverse scaling is 2 Input Note 1 0 10mV DC available 0 5 1 5 0 10V DC Note 2 Current 4 20mA DC An external receiving resistor is provided Scaling reverse scaling available Note 2 A I90 100 240V AC 10 50 60Hz 3 Power supply 08 24V AC 50 60Hz DC 10 0 None Separate setting separate output 2 point a contact COM used commonly Contact rating 240V AC 1 5A resistive load 4 Alarm output option 0 None 3 0 10mV DC Output resistance 10Q Scaling reverse 14 20mA DC Load resistance 3009 scaling available 5 Analog output or sensor power supply 4 max Within option Note 3 e O 10V DC Load current 1mA max measuring range 8 Sensor power supply 24V 3V DC 25mA max Fee cator RCH 0 None Communication function 5 IRS 485 option 7 RS 232C 0 Without 7 Remarks Sy 9 With Note 1 The instrument supports full un
15. caling lower limit value is Ao displayed or can be set Reverse scaling is available Note The same value cannot be set for the lower limit value and the higher limit value on screen 1 16 Measuring range lower limit value to Ini Lower limit value higher limit value 1 16 Analog output scaling higher limit value The analog output scaling higher limit value is Ao displayed or can be set Reverse scaling is available Note The same value cannot be set for the lower limit value on screen 1 15 and the higher limit value Measuring range lower limit value to Ini Higher limit value higher limit value 1 17 Communication mode I TII The communication mode is displayed or can be Ce a 1 Aan set LOC Local mode Data can be read out via communication COM Communication mode Data can be set and read out via communication Once the communication mode is modified to COM via communication the setting can no longer be made with front panel keys However the Note modification from COM to LOC is available For details refer to the separated Communication Interface Instruction Manual Ini Loc R Loc com 1 18 Communication protocol The communication protocol is displayed or can be set SHIM Shimaden protocol ASC MODBUS ASCII RTU MODBUS RTU R SHIM ASC RTU Ini SHIM 1 19 Communication address I The communication address is displayed or can i Addr i
16. cation data Setting method Using four key switches on the front panel Setting protection feature by key lock ON OFF is provided Setting range Same as the measuring range Input type Thermocouple R T D voltage mV V Universal input Thermocouple B R S K E J T N U L DIN43710 WRe5 26 For details refer to the Measuring range code table Lead wire tolerable resistance 1000 max Input impedance 500kQ min Burnout Standard feature up scale Cold junction C within accuracy maintain range 18 28 C A 1 compensation o P 419 ABS accuracy 2 C ambient temperature 5 18 C 28 45 C R T D JIS Pt100 3 wire type JPt100 3 wire type Amperage Approx 0 25mA Output accuracy 0 3 FS of display value Scaling Within measuring range or within input scaling range reverse scaling can be set Output update cycle 0 25 secs Isolation Isolated between analog output and input between analog output and alarm output between analog output and communication or between analog output and system Sensor power supply option Output rating 24V 3VDC 25mA max Depending upon instrument s power ON OFF status Isolation Isolated between sensor power supply and input between sensor power supply and alarm output between sensor power supply and communication or between sensor power supply and system Restrictions Senso
17. e layout in 2 5 Terminal arrangement e Use ring tongue terminals of 7mm or narrower width to meet M3 5 screws e Incase of thermocouple input use a compensation wire with the type of thermocouple selected The external resistance should be100Q or less e Incase of R T D input the resistance value per lead wire should be 50 or less and all three wires should have the same resistance value e Avoid arranging the input signal line to pass through the same conduit or duct with high voltage power lines e The shield wire one point grounding is effective to eliminate electrostatic induction noises e Aneffective way to eliminate the magnetic induction noises is to twist the input wire in short and equal intervals e For the source power connection use a wire or cable having a cross section of 1mm or larger and a performance capacity equivalent to 600V vinyl insulation wire e The grounding wire should have a cross section of 2mm or larger and the grounding work should ensure a ground resistance of 1000 or less e The symbol expresses the functional earth terminal Please connect it to the ground as much as possible to avoid the adverse impact from noise e Screw the terminal connection securely Tightening torque 1 1 Nm 11kgf cm e Noise filter In case the instruments are affected by the power supply noise install a noise filter to avoid operational errors Mount the noise filter on the grounded panel and connect the noi
18. e next display screen OO Alarm 2 Shifting a display screen to the setting screen ED inhibit Returning from a setting screen to the display screen D ORO Analog output scaling Shifting from 0 0 screen to 1 0 screen approx 2 secs lower limit value D Key operations on screens of Mode 1 Screen Group Analog output scaling higher limit value Mode 1 Screen Group consists of screens that are used less often DO than Mode 0 screens and are required according to the input type or controllability The commonly used key operations are as follows Communication mode Shifting a display screen to the next display screen DO Returning from a display screen to the previous display screen rO Commu neanen Shifting a display screen to the setting screen DO Communication Returning from a setting screen to the display screen CD address Returning from any display screen of Mode 1 DO to 1 0 screen Communication y data format Returning from 1 0 screen to 0 0 screen approx 2 secs or OR M Communication start character Auto return feature LOLO Ra a tr S ee Communication If no key operation is executed on any screen but the Basic screen BCC operation 0 0 for three minutes or more the screen returns to the Basic screen automatically LOLO Communication speed OO 1 e Communication rut n delay igEL i lt gt __ eii Dlo 22 to 1 0 screen SD16A Instruction Manual 6 2 Power ON Screen
19. e used from this sub section R Measuring range lower limit to higher limit value Ini Higher limit value AL Setting display is available Setting display is available when z when the alarm option is the analog output option is 0 6 Alarm 2 setting value supported supported 2 A 2 setti lue is displ d b t Setting display is available Ag pad I am 2 56 i ing va ve isp aye y CAN RE AL ars 3 I L I One of the following Alarm 2 action types 1 12 is displayed on the screen when the communication option a Aa h ae is supported A1HA Higher limit absolute value x A1LA Lower limit absolute value mV Setting display is available x Setting display is not available A1H A Higher limit absolute value with latching nA when the voltage or current V when the voltage or current input A1L A Lower limit absolute value with latching input is specified is specified R Setting range Ini Initial value Note This screen is not displayed when non or So scale over is selected on Alarm 2 code screen 1 12 0 0 Basic screen RJ Measuring range lower limit to higher limit value Ini Lower limit value PV measured value is displayed 6 4 Mode 1 Screen Group In case the Alarm 1 or 2 signal is output with the latching feature use 1 0_Mode 1 initial screen Note t key on this screen to release the Alarm 1 latching or use This is the heading screen of Mode 1 screens D key on this screen to release the A
20. ew point e Strong vibrations or impacts are generated or transferred e High voltage power lines exist in the neighborhood or induction interference e Exposure to direct sunlight or dew drops e The elevation is above 2000m Note The environmental conditions fall under installation category Il of IEC 60664 and the pollution degree is 2 2 2 Mounting 1 Cuta fitting hole by referring to the panel cutout dimensions in section 2 3 The applicable thickness of the panel is 1 0 4 0mm 2 Insert the indicator into the hole from the front of the panel as it has catching claws to fix it in position Note As the SD16A is a panel installation type indicator use it by mounting on a panel 2 3 External dimensions and panel cutout External dimensions 96 11 100 m a OS s U S E q a cha m 0 A OMa 0 qm SrainaADER by A Unit mm Panel cutout 920 3 E 3 110min Unit mm 2 4 Wiring AN WARNING e When wiring the unit be sure to cut the power supply OFF or there will be a risk of electric shock e Make sure the protective conductor terminal is grounded Otherwise a serious electric shock may result e After completing the wiring do not touch the terminals and electrically charged parts while the power is ON e Make wiring according to th
21. iversal input however please select one of two codes as an external receiving resistor 2500 is supplied for current input If no external receiving resistor is required a code 8 specification product can be used for current input Note 2 Scaling range 1999 9999 Unit Span 10 10000 Unit Note 3 When the 08 power supply code 24V AC DC is selected the sensor power supply cannot be selected Accessory list check e Unit label seal 1 sheet e Instruction Manual 1 copy e Communication Interface Manual in case the optional communication option is selected 1 copy Contact our local agent or exp dept shimaden co jp via e mail for any problems about the product accessories or related items AOG 1 2 Notes for use e Avoid operating the front panel keys with hard or sharp objects Lightly touch the operating keys with your fingertips for operation e When cleaning do not use a solvent such as a thinner Wipe the instrument with a dry cloth lightly 2 Installation and wiring 2 1 Installation site environmental conditions A CAUTION Do not install the instrument in such environmental conditions as those listed below Otherwise damage may be caused to the instrument even resulting in fire e Flammable or corrosive gas oil soot or dust that deteriorates the insulation is generated or abundant e Ambient temperature is below 10 C or above 50 C e Ambient humidity is higher than 90 RH or below d
22. larm 2 latching 0 14 Alarm 1 latching release i EA q This screen is displayed when Alarm 1 is in the AL ie E E latching state and is used for releasing it from that aiai aes state 1 1 Key lock Key lock status is displayed or can be set When the key lock is set to ON parameter value modification is not allowed This screen is displayed in case Alarm 1 code 1 1 is selected from the one with latching and when the R OFF ON ini OFF instrument is in the latching state Set the parameter RSET to stop the alarm output 1 2 Display update cycle As for the latching feature refer to Latching feature of 7 1 Alarm output The display update cycle of PV is displayed or can be set KEEP Alarm output is ON with latching feature RSET Releasing the alarm with latching feature R 0 25 5 00 secs Set by 0 25 secs fini 0 25 25 5 Set by 0 Note The Alarm 1 output signal with latching feature can also be set to OFF by pressing A key on the Basic screen 0 0 1 3 Measuring range R KEEP RSET Ini KEEP The input type is displayed or can be set Refer to 4 Measuring range code table for input type 0 2 Alarm 2 latching release details RLF This screen is displayed when Alarm 2 is in the R 01 12 31 34 71 81 83 95 Ini 05 K TC 0 1200 C Oa E E latching state and is used for releasing it from that Sere ay ee state 1
23. one 81 3 3931 7891 Fax 81 3e3931 3089 E mail expedept shimaden co jp Any questions should be directed to your local agent or send an e mail to exp dept shimaden co jp Printed in Japan
24. r power supply can t be selected when the analog output is selected Sensor power supply can t be selected when the power supply 24V is selected Communica Communication type n option RS 232C RS 485 Communication system Half duplex asynchronous communication method Communication 1200 2400 4800 9600 19200 bps connectable devices speed Data format 7E1 7E2 7N1 7N2 8E1 8E2 8N1 8N2 Communication 1 100 address Number of 31 devices max for RS 485 Delay 1 100 msec Communication Shimaden standard protocol MODBUS ASCII MODBUS protocol RTU start character and BCC operation method can be selected for Shimaden standard protocol Isolation Isolated between communication and input between communication and alarm output between communication and analog output sensor power supply or between communication and system Lead wire tolerable 5Q max wire each wire should have the same resistance resistance os mV 0 10mV DC Input impedance 500kQ gaj v 0 5 1 5 0 10VDC iii Current 4 20mA DC External receiving resistor 2500 supplied if specified Input scaling function Available in case of voltage mV V or current mA input Reverse scaling can be set Scaling range 1999 9999 counts Miscellaneous Data storage By nonvolatile memory EEPROM 2 Temperature 10 50 C 5 Humidi
25. rameter setting screen 3 Key switches Parameter key e On a display screen shifts the screen to the next e Switches from Mode 0 screen group Mode 1 screen group to Mode 1 screen group Mode 0 screen group By pressing this key for two seconds or longer on screen 0 0 or screen 1 0 shifts to the screen 1 0 or to the screen 0 0 respectively Down key e Onasetting screen decrements the value The last digit decimal point blinks until the value is registered by pressing the Entry key Up key e On a setting screen increments the value The last digit decimal point blinks until the value is registered by pressing the Entry key Entry key e On a setting screen registers the value that is modified by the Up Down key The last digit of the decimal point blinks until this registration by pressing the Entry key e Shifts between a display screen and the setting screen In this case the light of the last digit of decimal point goes out 100 4 Measuring range code table Input type Code Measuring range Measuring range Note C F B 01 0 1800 0 3300 Note 2 R 02 0 1700 0 3100 S 03 0 1700 0 3100 o K 04 199 9 800 0 300 1500 2 05 0 1200 0 2200 8 E 06 0 700 0 1300 J 07 0 600 O 1100 2 2 T 08 199 9 300 0 300 600 Note 3 z 5 N 09 0 1300 0 2300 3 U 10
26. se filter output and the power supply terminal of the indicator with the minimum possible distance Make wire with the mini a possible distance 100 200V AC 100 200V AC Noise filter Recommended noise filter Grounding ZMB2203 13 from TDK 2 5 Terminal arrangement Alarm outs oe AL1 oe RS 232C Com Rs a8s 11 12 3 DOGO OO Oee eo LG 100 240V AC 50 60Hz SD16A Instruction Manual Analog out S sorfower Note Do not connect other than the specified input type to terminal 3 Names and functions for front panel 3 1 Names Front panel 1 Monitoring LEDs 2 LED display for measured value 3 2 Functions 1 Monitoring LEDs AL1 Alarm 1 output monitoring LED red The LED lights when the assigned alarm is ON AL2 Alarm 2 output monitoring LED red The LED lights when the assigned alarm is ON SET parameter setting monitoring LED green The LED lights when the screen displayed is not the basic screen 0 0 COM communication monitoring LED green The LED lights when the communication mode is on remote control 2 LED display for measured value red The current PV value is displayed on the basic screen 0 0 The type of parameters is displayed on each parameter display screen The set value is displayed on each pa
27. ted between alarm output 1 and alarm output 2 Distributed in New Zealand by gt Intech instruments LTD Christchurch Ph 6433430646 Fx 6433430649 Auckland i 098271930 www intech co nz 098271931 Sales intech co nz Power supply voltage 100 240V AC 10 50 60Hz frequency 24V AC 50 60Hz DC 10 option Power consumption 11VA 100 240V AC 8VA 24V AC 5W 24V DC p Safety IEC61010 1 EN61010 1 a G age EMC EN61326 1997 A1 1998 A2 2001 A3 2003 Ed hd s EMC testing display accuracy 3 FS Dust proof drip proof IP66 equivalent Isolation resistance Between all input output terminals and power terminal 500V DC 20MQ min Between all input output terminals and ground terminal 500V DC 20MQ min Dielectric strength Between all input output terminals and power terminal 2300V AC for one minute Between power terminal and ground terminal 1500V AC for one minute Case material Black PPO resin molding equivalent to UL94V 1 External dimensions H48 x W96 x D111 mm inside of panel 100mm Mounting Push in panel one touch mount Panel thickness 1 0 4 0 mm Panel cutout H45 x W92 mm Weight Approx 250g The contents of this manual are subject to change without notice Temperature and Humidity Control Specialists SHIMADEN CO LTD http www shimaden co jp Head Office 230 10 Kitamachi Nerimaeku Tokyo 179 0081 Japan Ph
28. to the requirements of IEC61010 1 e Do not apply over rated voltage or current to the input terminal That will cause the risk of the instrument being damaged and its life reduced As for the rating please refer to 8 Specification In case the input type is voltage mV or V or current 4 20mA the unit connected to the output terminal should conform to the requirements of IEC61010 1 e Take care to prevent metal or other foreign matter from obstructing the ventilating hole for heat radiation It will cause damage to the instrument and may even result in fire e Do not block the ventilating hole Also avoid dust accumulation Any rise in temperature or insulation failure may result in a risk of the instrument being damaged and its life reduced As for the clearance space for installing the instrument refer to 2 3 External dimensions and panel cutout e Repeating withstanding tests on voltage noise surging may lead to the deterioration of the instrument so please be careful e Strictly refrain from remodeling and using the instrument improperly Copyright SHIMADEN CO LTD All rights reserved SD16A Instruction Manual 1 Introduction 1 1 Check before use Although the instrument passes thorough quality checks before shipment when the instrument is delivered please confirm the type code number check the external conditions and the list of accessories to make sure that there is no apparent d
29. ty 90 RH max no dew condensation E Height 2000m above sea level or lower fe amp Installation 5 o catego m KE gory z Degree of 2 pollution 2 Span 10 10000 counts Decimal places None 0 0 0 00 0 000 Sampling cycle 0 25 secs PV bias 1999 2000 PV filter 0 100 secs PV filter is set to OFF when 0 sec Isolation Isolated between input and analog output sensor power supply or between input and communication Not isolated between input and system Number of alarm points Alarm output option 2 points AL1 and AL2 normally open COM is commonly used Alarm type One of the following six types can be assigned to each alarm None higher limit absolute value alarm with latching higher limit absolute value alarm without latching lower limit absolute value alarm with latching lower limit absolute value alarm without latching Scale over Setting range Within measuring range or within scaling range Alarm action ON OFF action Hysteresis 1 999 Unit Inhibit action ON OFF can be selected for each alarm output Output type Contact 1a COM is commonly used Rating 240V AC 1 5A resistive load Output update cycle 0 25 secs Isolation Isolated between alarm output and input between alarm output and analog output sensor power supply between alarm output and communication or between alarm output and system Not isola