Home

Na-de 10100 Owners Manual

image

Contents

1. wu 6 1 of 2 Wall mount sensor detection range from side large motion Wall mount sensor detection range from top large motion 8m e ee Motion Sensor Settings and Adjustments The motion sensor is a Passive Infra Red PIR type electronic occupancy detector which in turn switches the lights when connected to the motion sensor There are two adjustments that can be made to influence the operation of the motion sensor 1 TIME time delay after motion sound until shut off 2 LUX LIGHT level of ambient light sensitivity The two adjustment settings are as follows Time setting range 10sec to 35min Lux light sensitivity 2 to 2 000 LUX Manual Override For manual control the 10100 motion sensor features a convenient manual override switch If the switch is set to AUTO the motion sensor will be active Setting the switch to OFF will turn the lights off and ON will turn the lights on Motion Sensor Adjustments TIME LUX Manual override switch The motion sensor s settings can be adjusted as follows Step 1 Adjust the TIME setting to minimum Turn the TIME control fully anti clockwise to set to the 10sec testing setting Step 2 Adjust the LUX LIGHT ambient light setting With the LUX LIGHT control turned fully anti clockwise gently cover the sensor lens until the light turns off approximately 10sec Uncover the sensor lens and adjust the LUX LIGHT control until the light comes on If the
2. LUX LIGHT control is set to maximum fully clockwise the lights will turn ON whenever the room is occupied even in full daylight If the LUX LIGHT control is set to minimum fully anti clockwise the lights will only turn ON when the room is occupied AND is receiving low natural light Step 3 Adjust the TIME setting Turn the TIME control clockwise until the required delay is reached Min 10sec max 35min Factory time out is pre set to 10 seconds NOTE All the time intervals are within approximately 10 seconds of the stated time out interval Eco Heat Equipment August 2015 WARNING Controlling a load in excess of the specified ratings will damage the unit and lights and could pose risk of fire and electric shock WARNING Do not install this unit to control a power socket OTHER CAUTIONS Disconnect power when working on electrical outlets or components Do not push on the surface of the lens The 10100 motion sensor is intended to replace a standard wall mounted light switch Cleaning Carefully wipe sensor with a soft damp cloth Do not apply pressure to the lens Recycling Please recycle all packaging material that came with the motion sensor Trouble Shooting The unit will No mains power not switch No movement is Move towards the unit in on detected in detection detection zone zone Adjust setting on the LUX LIGHT Wrong LUX LIGHT level settings setting Refer to the Elec
3. Remove mounting box from back of sensor 3 Affix mounting box to wall or ceiling 4 Pass wires through hole in mounting box 3 Connect sensor to wires as per diagram 4 Reattach sensor to mounting box 5 Restore power at circuit breaker or fuse Sensor calibration Note The sensor will calibrate for up to 10 minutes after it has been connected for the first time Ensure that there is no motion within the sensor s range during this period This is only necessary during installation or when the mains supply is disconnected Eco Heat Equipment August 2015 Mounting box diagram Holes for mounting Wire pass through hole 80mm x 80mm Installation wire diagram Live In Live In Power Supply 220 240V AC 50 60Hz Sensor Neutral Neutral Operation and Field of View The motion sensor detects motion within its coverage area of 64m ceiling mount and 25m wall mount and controls the associated lighting connected to the sensor The passive infra red PIR sensor is sensitive to the heat emitted by the human body In order to trigger the sensor the source of heat must move from one zone of detection to another The device is most effective in sensing motion across its field of view and less effective sensing motion towards or away from its field of view Ceiling mount sensor detection range from side large motion a 9M Ceiling mount sensor detection range from top large motion
4. Wall or Ceiling Mount Motion Sensor 10100 User Manual 10100 General The 10100 is a wall or ceiling mount motion sensor using PIR technology This sensor is ideal for small offices corridors and parking bays If after reviewing this guide you require additional information or assistance please contact Eco Heat Equipment at info ecoheat co za 27 0 861 999 887 or www ecoheat co za Technical Specifications Voltage 230 240V AC Frequency 50Hz Load Incandescent 1 000W Fluorescent 400W CFL 600W Detection Range Ceiling mount 360 9m Wall mount 180 8m Light level 2 2 000 LUX Time setting 10 seconds 35 minutes Installation height Ceiling 2 8m Wall 1 2m Safety Any incorrect use or installation procedure not recommended by the manufacturer may cause fire electrical shock or injury to persons Box Contents Your box should contain the following items Sensor including mounting box Installation Instructions WARNING ALL WIRING MUST BE DONE IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES AND STANDARDS Note motion sensors respond to rapid changes in temperature so care should be taken not to mount the device near a climate control source i e heaters or air conditioners Hot or cold draughts will seem like body motion to the sensor and will trigger the device Recommended distance from climate control devices is 2m 1 Turn power off at circuit breaker or fuse 2
5. trical Electrical circuitry faulty Installation section to ensure Electrical Installation not correct installation done correctly Have a certified electrician Unit may be faulty disconnect and test the unit Contact Eco Heat Equipment Check mains power is on Unit stays Continuous movement in on detection zone settings Adjust setting on the LUX LIGHT The sensor is not mounted correctly for reliable operation Wrong LUX LIGHT level setting Time setting control is set too far Unit may be faulty Adjust the time setting control Contact Eco Heat Equipment permanently Warranty The sensor has a three 3 year warranty after the date of the original purchase Please keep your original receipt as this will be required for any claims under this warranty The warranty is a strictly carry in policy The sensor s must be returned to Eco Heat offices for a claim to be processed The warranty does not cover damage from misuse neglect or abuse products that have been modified in any way shipping and handling cost associated with the product damage resulting from accidents lightning fire water power surges natural disasters and or incorrect installation For more information view the Return Refund Policy at ecoheat co za terms ohp Due to minor improvements in design or otherwise the product you purchase may differ from the one shown in this leaflet For more information or ad
6. vice on this or any other Eco Heat Equipment products visit www ecoheat co za or phone 27 0 861 999 887 Indemnity The Author and supplier shall not be held liable for any loss injury or damage of whatsoever nature whether consequential or not either contractual sustained to or caused by or which may arise through the use of any comments suggestions circuitry services or equipment offered for purchase The User indemnifies the author and supplier and agrees not to hold him her responsible for any damages losses and or liabilities including legal costs on a scale as between attorney and user arising from or through the use of circuit diagrams equipment and services whether such circuit diagrams equipment and services were used with the consent of the User or not All risks attached to the use of circuit diagrams equipment and the connection thereof to the User s equipment shall be deemed to have passed onto the User once having purchased such equipment from the author or supplier is V ec sensor 2 of 2

Download Pdf Manuals

image

Related Search

Related Contents

Kicker 2006 ZX300.1 Owner's Manual  Product Manual - The Safety Equipment Store  Bedienungsanleitung de testo 350 M/XL · Logger  全ページ一括ダウンロード  仕様書ダウンロード(PDF形式  OWNER´S MANUAL - Powertec Outboards  IVA user manual  Formalités, mode d`emploi - Chambre de Commerce et d`Industrie  2015-J-0558  KE-M2 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file