Home
        Multimeter with IR Thermometer
         Contents
1.     IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME  the batteries should be  removed to prevent damage to the unit     BATTERY and FUSE Replacement    WARNING  To avoid electric shock  disconnect the test leads from any source of voltage before  removing the battery cover     PS    Turn power off and disconnect the test leads from the meter   Lift the meter stand to expose the battery cover     Open the rear battery fuse compartment by removing the Phillips head screw on the lower rear of  the meter     Carefully pull down on the cover just enough to release the latch and then lift it off  The cover will  not pull down all the way     Remove the old battery or fuse and install a new one of the correct rating   Place the battery fuse cover back in place  Secure with the screw     WARNING  To avoid electric shock  do not operate the meter until the battery cover is in place and  fastened securely     NOTE  If the meter does not work properly  check the fuses and replace the battery to make sure that    they are still good and that they are properly inserted     Battery Safety Reminders    o Please dispose of batteries responsibly  observe local  state  and national regulations   o Never dispose of batteries in a fire  batteries may explode or leak   o Never mix battery types  install new batteries of the same type     10 EX210_EX210T en US_v1 5 9 15    Specifications                                                                                     Function Range Resol
2.  Rotate the function switch to the D position     2  Insert the black lead banana plug into the negative COM jack   Insert the red test lead banana plug into the positive 2  jack     3  Press the MODE button to indicate   M   on the display  4  Touch the test probe tips to the circuit or wire you wish to check   5  If the resistance is less than the continuity threshold  the audible signal will sound     DIODE TEST  1  Rotate the function switch to the green    position     2  Insert the black test lead banana plug into the negative COM jack and the red test  lead banana plug into the positive Dt jack     3  Press the MODE button to indicate     gt     and    V    on the display     4  Touch the test probes to the diode under test  Forward voltage will typically indicate  0 400 to 0 700V  Reverse voltage will indicate    OL     Shorted devices will indicate  near OV and an open device will indicate    OL    in both polarities     7 EX210_EX210T en US_v1 5 9 15    NON CONTACT INFRARED TEMPERATURE MEASUREMENTS    1  Rotate the function switch to the IR position  The upper right four digit temperature display will  switch on     2  Press the MODE button to select  F or  C   3  Aim the infrared sensor  top of meter  at the surface to be measured     4  Press and Hold the IRT   button to turn on the IR thermometer and laser pointer  The laser  pointer identifies the surface spot to be measured and    SCAN    will flash in the display     5  Read the temperature in the display     
3.  of shipment  a six month limited warranty applies to sensors and cables   If it should become necessary to return the  instrument for service during or beyond the warranty period  contact the Customer Service Department for authorization  Visit  the website www extech com for contact information  A Return Authorization  RA  number must be issued before any product is  returned  The sender is responsible for shipping charges  freight  insurance and proper packaging to prevent damage in transit   This warranty does not apply to defects resulting from action of the user such as misuse  improper wiring  operation outside of  specification  improper maintenance or repair  or unauthorized modification  FLIR Systems  Inc  specifically disclaims any implied  warranties or merchantability or fitness for a specific purpose and will not be liable for any direct  indirect  incidental or  consequential damages  FLIR s total liability is limited to repair or replacement of the product  The warranty set forth above is  inclusive and no other warranty  whether written or oral  is expressed or implied        Calibration  Repair  and Customer Care Services       FLIR Systems  Inc  offers repair and calibration services for the Extech Instruments products we sell   NIST certification for most products is also provided  Call the Customer Service Department for  information on calibration services available for this product  Annual calibrations should be  performed to verify meter performance an
4. 3063 USA  Certificado ISO 9001       Copyright O 2013 2015 FLIR Systems  Inc     Reservados todos los derechos  incluyendo el derecho de reproducci  n total o parcial en cualquier medio    www extech com    15 EX210_EX210T en US_v1 5 9 15    
5. 6  The area of the surface to be measured must be larger than the spot size as determined by the  distance to spot size values listed in the specification table     7  Release the IRT O button to turn the IR thermometer and laser pointer off     HOLD    and the  final measured value will remain in the display     WARNING  Do not directly view or direct the laser pointer at an eye  Low power visible lasers    do nat normally present a hazard  but may present some potential for hazard if viewed directly for  extended periods of time           AVOID EXPOSURE  ATM Laser radiation is emitted  from this aperture  LASER RADIATION DO NOT STARE INTO BEAM  OUTPUT lt 1mW WAVELENGTH 630 670nm  CLASS 2 LASER PRODUCT  Complies with  FDA 21 CFR 1040 10 and 1040 11  IEC 60825 1  2001 08  Edition 1 2  EN 60825 1 1994 A11 1996 A2 2001 A1 2002          IR Spot to Distance Diagram    The 4 1 spot to distance ratio determines the size of the measured surface area with respect to the  distance the meter is held away from the surface                             IR Measurement Notes    1  The object under test should be larger than the spot  target  size calculated by the field of view  diagram     2  Ifthe surface of the object under test is covered with frost  oil  grime  etc   clean before taking  measurements     3  If an object s surface is highly reflective  apply masking tape or flat black paint to the surface  before measuring     4  The meter will not make measurements through glass steam  
6. User Guide    EXTECH    INSTRUMENTS          Multimeter with IR Thermometer    Extech EX210 and EX210T  True RMS                                                  Introduction       Thank you for selecting the Extech EX210 EX210T True RMS  EX210T only  Autoranging Multimeter   This meter measures AC DC Voltage  AC DC Current  Resistance  Diode Test  and Continuity plus  non contact InfraRed Temperature  Proper use and care of this meter will provide many years of  reliable service  Please visit the Extech Instruments website  www extech com  to check for the latest  version of this User Guide  Extech Instruments is an ISO 9001 certified company     Safety       This symbol adjacent to another symbol  terminal or operating device indicates  that the operator must refer to an explanation in the Operating Instructions to  avoid personal injury or damage to the meter     This CAUTION symbol indicates a potentially hazardous situation  which if not  CAUTION A  avoided  may result damage to the product     This WARNING symbol indicates a potentially hazardous situation  which if not  avoided  could result in death or serious injury     MAX    600V This symbol advises the user that the terminal s  so marked must not be  connected to a circuit point at which the voltage with respect to earth ground  exceeds  in this case  600 VAC or VDC     voltages  For maximum safety  the meter and its test leads should not be handled  when these terminals are energized     This symbol indicates tha
7. com       R  parations et retours   Option 4   E mail   repair extech com  Les sp  cifications produit sont sujettes    modifications sans pr  avis   Pour les toutes derni  res informations  veuillez visiter notre site Web   www extech com  FLIR Commercial Systems  Inc   9 Townsend West  Nashua  NH 03063 USA    Certifi   ISO 9001       Copyright O 2013 2015 FLIR Systems  Inc     Tous droits r  serv  s  y compris la reproduction partielle ou totale sous quelque forme que ce soit     www extech com    14 EX210_EX210T en US_v1 5 9 15    Garantia       FLIR Systems  Inc   garantiza este dispositivo marca Extech Instruments para estar libre de defectos en partes o mano de obra  durante un a  o a partir de la fecha de embarque  se aplica una garant  a limitada de seis meses para cables y sensores   Si fuera  necesario regresar el instrumento para servicio durante o despu  s del periodo de garant  a  llame al Departamento de Servicio a  Clientes para obtener autorizaci  n  Visite www extech com para Informaci  n de contacto  Se debe expedir un n  mero de  Autorizaci  n de Devoluci  n  AD  antes de regresar cualquier producto  El remitente es responsable de los gastos de embarque   flete  seguro y empaque apropiado para prevenir da  os en tr  nsito  Esta garant  a no se aplica a defectos resultantes de las  acciones del usuario como el mal uso  alambrado equivocado  operaci  n fuera de las especificaciones  mantenimiento o  reparaci  n inadecuada o modificaci  n no autorizada  FLIR S
8. d accuracy  Technical support and general customer  service is also provided  refer to the contact information provided below     Support Lines  U S   877  439 8324  International   1  603  324 7800    Technical Support  Option 3  E mail  support extech com  Repair  amp  Returns  Option 4  E mail  repair extech com  Product specifications are subject to change without notice  Please visit our website for the most up to date information  www extech com  FLIR Commercial Systems  Inc   9 Townsend West  Nashua  NH 03063 USA  ISO 9001 Certified       Copyright O 2013 2015 FLIR Systems  Inc     All rights reserved including the right of reproduction in whole or in part in any form    www extech com    13 EX210_EX210T en US_v1 5 9 15    Garantie       FLIR Systems  Inc  garantit que cet appareil Extech Instruments est exempt de d  fauts mat  riaux et de fabrication pendant un  an    partir de la date d envoi  une garantie limit  e de six mois s applique aux capteurs et aux c  bles   Si le renvoi de l appareil  pour r  paration devient n  cessaire durant ou apr  s la p  riode de garantie  contactez le service client pour autorisation  Pour  obtenir les coordonn  es  visitez le site Web suivant   www extech com  Un num  ro d autorisation de retour  AR  doit   tre d  livr    avant tout retour de produit  L   exp  diteur prend    sa charge les frais d exp  dition  le fret  l assurance et l emballage correct de  l appareil afin de pr  venir toute d  t  rioration durant le transport  Cett
9. dust  and smoke     5  To find a hot spot  aim the meter outside the area of interest then scan across  in an up and  down motion  until the hot spot is located     8 EX210_EX210T en US_v1 5 9 15    AUTORANGING MANUAL RANGE SELECTION    When the meter is first switched on  it automatically enters the AutoRanging mode  This  automatically selects the best range for the measurements being made and is generally the best  mode for most measurements  For measurement situations requiring that a range be manually  selected  perform the following     1  Press the RANGE button  The    AUTO    display indicator will turn off    2  Press the RANGE key to step through the available ranges until the range desired is selected   3  Press and hold the RANGE button for 2 seconds to exit manual ranging    Note  Manual ranging does not apply to the Temperature  Diode and Continuity functions     MAX  MAXIMUM READING  MODE  1  Press the MAX button to activate the MAX mode  The display icon  MAX  will appear  The meter  will display and hold the maximum reading and will update only when a new maximum value is  detected   2  Press the MAX button again to exit the mode   Note  Max does not apply to the Resistance  Diode and Continuity functions     DISPLAY BACKLIGHT  Press and hold the IRT      8 button for 2 second to turn the backlight on  The backlight will  automatically turn off after approximately 10 seconds or press and hold the button again for 2  seconds to manually turn it off     HOLD  T
10. e garantie ne s applique pas aux dommages imputables     l utilisateur  tels que l usage impropre ou abusif  un mauvais c  blage  une utilisation non conforme aux sp  cifications  un  entretien ou une r  paration incorrecte  ou toute modification non autoris  e  FLIR Systems  Inc  d  clinera sp  cifiquement toute  garantie ou qualit   marchande ou aptitude    l emploi pr  vu  et ne sera en aucun cas tenu responsable pour tout dommage  cons  quent  direct  indirect ou accidentel  La responsabilit   totale de FLIR est limit  e    la r  paration ou au remplacement du  produit  La garantie d  finie ci dessus est inclusive et aucune autre garantie    crite ou orale  n   est exprim  e ou implicite     Calibrage  r  paration et services apr  s vente       FLIR Systems  Inc  offre des services de calibrage et de r  paration pour les produits Extech  Instruments que nous commercialisons  Nous fournissons   galement une certification NIST pour la  plupart des produits  Contactez notre service client pour toute information sur les services de  calibrage disponibles pour ce produit  Un calibrage doit   tre effectu   chaque ann  e pour v  rifier les  performances et la pr  cision du m  tre  Nous offrons   galement une assistance technique et un  service    la client  le  Veuillez vous reporter aux coordonn  es fournies ci dessous     Lignes d   assistance    tats Unis  877  439 8324  international   1  603  324 7800    Service d   assistance technique   Option 3   E mail   support extech 
11. e input jack  12  COM input jack    X  D OL       Note  Tilt stand  test lead holders  and battery compartment are on rear of unit     Symbols and Enunciators        lt a  Continuity    gt t Diode test   u micro  10     amps   m milli  10     volts  amps   A Amps   k kilo  10     ohms    M mega  10     ohms   Q Ohms   V Volts   AC Alternating current  DC Direct current     F Degrees Fahrenheit    C Degrees Centigrade  MAX Maximum    AUTO Autoranging  HOLD Display hold  SCAN _ IR temperature in progress       HoD HN CL aio          EX210_EX210T en US_v1 5 9 15    Operating Instructions       WARNING  Risk of electrocution  High voltage circuits  both AC and DC  are extremely dangerous       and should be measured with great care     1  ALWAYS turn the function switch to the OFF position when the meter is not in use     2  If    OL    appears in the display during a measurement  the value exceeds the range you have  selected  Change to a higher range     AC DC VOLTAGE MEASUREMENTS  CAUTION  Do not measure DC voltages if a motor on the circuit is being switched ON or OFF   Large voltage surges may occur that can damage the meter     1  Rotate the function switch to the VAC or VDC position     2  Insert the black test lead banana plug into the negative COM jack  Insert the red  test lead banana plug into the positive V jack     3  Touch the black test probe tip to the negative side of the circuit   Touch the red test probe tip to the positive side of the circuit     4  Read the v
12. f the test leads and the meter itself for any damage before operating the  meter     e Use great care when making measurements if the voltages are greater than 25 VAC rms or 35  VDC  These voltages are considered a shock hazard     e Warning  This is a Class A device  This device can cause interference in residential areas     e Always discharge capacitors and remove power from the device under test before performing  Diode  Resistance or Continuity tests     e Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty  of connection to the recessed electrical contacts  Other means should be used to ensure that  the terminals are not  live      e If the equipment is used in a manner not specified by the manufacturer  the protection provided  by the equipment may be impaired     e This device must not be used by children  It contains hazardous objects as well as small parts  that the children could swallow     e Do not leave batteries and packing material lying around unattended  they can be dangerous  to children     e Inthe event that this device will be stored for an extended period of time  remove the batteries     e Expired or damaged batteries can leak and can be hazardous to skin  Use suitable hand  gloves in such cases     e Do not short circuit the battery  Do not place the battery near a fire     e Never mix battery types  Always install new batteries of the same type     3 EX210_EX210T en US_v1 5 9 15    SAFETY INSTRUCTIONS    Th
13. he HOLD function freezes the reading in the display  Press the HOLD button momentarily to  activate or to exit the HOLD function   Note  The HOLD button does not function in the IR measurement mode     AUTO SLEEP  If no button is pressed the auto sleep feature will place the meter in sleep mode after approximately  15 minutes of operation  If this happens  press any button to wake the meter or switch the meter to    OFF if it no longer in use     9 EX210_EX210T en US_v1 5 9 15    Maintenance       WARNING  To avoid electric shock  disconnect the test leads from any source of voltage before  removing the back cover or the battery or fuse covers    WARNING  To avoid electric shock  do not operate the meter until the battery and fuse covers are  in place and fastened securely     This MultiMeter is designed to provide years of dependable service  if the following care instructions  are followed     1    6       KEEP THE METER DRY  If it gets wet  wipe it off   2     USE AND STORE THE METER IN NORMAL TEMPERATURES  Temperature extremes can  shorten the life of the electronic parts and distort or melt plastic parts       HANDLE THE METER GENTLY AND CAREFULLY  Dropping it can damage the electronic parts    or the case       KEEP THE METER CLEAN  Wipe the case occasionally with a damp cloth  DO NOT use    chemicals  cleaning solvents  or detergents       USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE  Remove old or    weak batteries so they do not leak and damage the unit 
14. is meter has been designed for safe use  but must be operated with caution  The rules listed below  must be carefully followed for safe operation     1     NEVER apply voltage or current to the meter that exceeds the specified maximum                       Input Protection Limits  Function Maximum Input  V AC DC  Resistance  Diode Test  Continuity 600 VDC AC rms  yA or mA AC DC 200mA fused  A ACIDC 10A fused             USE EXTREME CAUTION when working with high voltages     DO NOT measure voltage if the voltage on the  COM  input jack exceeds 600V above earth  ground     NEVER connect the meter leads across a voltage source while the function switch is in the  current  resistance  or diode mode  Doing so can damage the meter     ALWAYS discharge filter capacitors in power supplies and disconnect the power when making  resistance or diode tests     ALWAYS turn off the power and disconnect the test leads before opening the covers to replace  the fuse or batteries     NEVER operate the meter unless the back cover and the battery and fuse covers are in place  and fastened securely     If the equipment is used in a manner not specified by the manufacturer  the protection provided  by the equipment may be impaired     4 EX210_EX210T en US_v1 5 9 15    Controls and Jacks       IR Thermometer   Laser Pointer   2000 count LCD   MAX button   MODE button   FUNCTION switch   mA  pA and 10A input jacks    O  NO ANA    IR Thermometer button  9  HOLD button  10  RANGE button    11  Positiv
15. old 20 to 50Q  test current  lt 1 5mA    Input Impedance  AC Response  ACV Bandwidth    IR Spectral response    IR Emissivity   IR distance ratio  Laser pointer  Display    Overrange indication    Auto Power Off  Polarity  Measurement Rate  Battery   Fuses    Operating Temperature  Storage Temperature  Operating Humidity    Storage Humidity  Operating Altitude  Weight   Size   Safety    Approvals    10MQ VDC VAC   True rms  EX210T only    40Hz to 1000Hz   6 to 16um   0 95 fixed   4 1   Class 2 laser  lt  1mW power  Wavelength is 630 to 670nm   2 000 count backlit liquid crystal display      OL    is displayed   15 minutes  approximately    Automatic  no indication for positive   Minus     sign for negative   2 times per second  nominal   One 9 volt  NEDA 1604  battery   mA  HA ranges  200mA 250V ceramic fast blow      A    range  10A 600V ceramic fast blow   14  F to 122  F   10  C to 40  C    14  F to 140  F   10  C to 60  C    Max 80  up to 31  C  87  F  decreasing linearly to 50  at 40  C  104  F    lt 80    7000 ft  2000m  maximum   9 17 oz   260 g    5 8x2 9x1 6     147x76x42 mm    This meter is intended for origin of installation use and protected  against  the users  by double insulation per IEC EN 61010 1 2001 and IEC EN  61010 031 2002 to Category III 600V  Pollution Degree 2    CE    12 EX210_EX210T en US_v1 5 9 15       Warranty    FLIR Systems  Inc  warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year  from date
16. oltage in the display     AC DC CURRENT MEASUREMENTS  1  Insert the black test lead banana plug into the negative COM jack   2  Press the MODE button to indicate    DC    or    AC    on the display     3  For current measurements up to 2000pA  set the function switch to the pA position  and insert the red test lead banana plug into the pA mA jack     4  For current measurements up to 200 mA DC  set the function switch to the mA  position and insert the red test lead banana plug into the HA mA jack     5  For current measurements up to 10A DC  set the function switch to the 10A position  and insert the red test lead banana plug into the 10A jack        6  Connect the test leads in series with the circuit under test        7  Apply power to the circuit   8  Read the current in the display     6 EX210_EX210T en US_v1 5 9 15    RESISTANCE MEASUREMENTS    WARNING  To avoid electric shock  disconnect power to the unit under test and discharge all    capacitors before taking any resistance measurements  Remove the batteries and unplug the line  cords        1  Rotate the function switch to the Q position     2  Insert the black test lead banana plug into the negative COM jack   Insert the red test lead banana plug into the positive Q jack     3  Touch the test probe tips across the device under test   4  Read the resistance in the display     CONTINUITY CHECK    WARNING  To avoid electric shock  never measure continuity on circuits or wires that have a       voltage potential     1 
17. t a device is protected throughout by double insulation or  reinforced insulation     This symbol adjacent to one or more terminals identifies them as being associated  with ranges that may  in normal use  be subjected to particularly hazardous  PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY  OVERVOLTAGE CATEGORY I  Equipment of OVERVOLTAGE CATEGORY   is equipment for connection to circuits in which  measures are taken to limit the transient overvoltages to an appropriate low level   Note     Examples include protected electronic circuits   OVERVOLTAGE CATEGORY II  Equipment of OVERVOLTAGE CATEGORY ll is energy consuming equipment to be supplied from  the fixed installation   Note     Examples include household  office  and laboratory appliances   OVERVOLTAGE CATEGORY III  Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations   Note     Examples include switches in the fixed installation and some equipment for industrial use  with permanent connection to the fixed installation   OVERVOLTAGE CATEGORY IV  Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation   Note     Examples include electricity meters and primary over current protection equipment    2 EX210_EX210T en US_v1 5 9 15    CAUTIONS    e Improper use of this meter can cause damage  shock  injury or death  Read and understand  this user manual before operating the meter     e Always remove the test leads before replacing the battery or fuses     e Inspect the condition o
18. ution Accuracy  DC Voltage 200 mV 0 1 mV   0 8  reading   6 digits   2V 0 001V    0 5  reading   2 digits   20V 0 01V  200V 0 1V    0 8  reading   2 digits   600V 1V  AC Voltage 200 mV 0 1 mV   50 60Hz  2V 0 001V  20V 0 01V   1 5  reading   6 digits   True RMS 200V 0 1V   EX210T only   600V 1V  All AC voltage ranges are specified from 5  of range to 100  of range  DC Current 200 pA 0 1 pA  2000 pA 1 pA    1 5  reading   5 digits   20 mA 0 01 mA  200 mA 0 1 mA  2 000 0 001 A    2 5  reading   5 digits   10A 0 01A  Note 10A for 30 sec max  AC Current 200 pA 0 1 HA   50 60Hz  2000 pA 1 pA    1 5  reading   8 digits   20 mA 0 01 mA  True RMS  200 mA 0 1 mA   EX210T only   2 000 0 001       3 0  reading   5 digits   10A 0 01 A                Note  10A for 30 sec max       NOTE  Accuracy is stated at 18  C to 28  C  65  F to 83  F  and less than 75  RH     EX210_EX210T en US_v1 5 9 15                                                                            Function Range Resolution Accuracy  Resistance 200 Q 0 1Q   0 8  reading   5 digits   2kQ 0 001 kQ  20 kQ 0 01 kQ   0 8  reading   2 digits   200 kQ 0 1 KQ  2MQ 0 001 MQ    2 5  reading   8 digits   20 MQ 0 01 MQ  Temperature IR  20 to 0  C  4  C  0 to 93  C   2 0 rdg or 2  C   93 to 230  C   3 0 rdg or 3  C   0 1  C   F   5 to 32  F   8  F  32 to 200  F   2 0 rdg or 4  F   200 to 446  F   3 0 rdg or 6  F   Enclosure Double molded  Diode Test Test current of 0 9mA maximum  open circuit voltage 2 8V DC typical  Continuity Thresh
19. ystems  Inc   rechaza especificamente cualesquier garant  as  impl  citas o factibilidad de comercializaci  n o idoneidad para cualquier prop  sito determinado y no ser   responsable por  cualesquier da  os directos  indirectos  incidentales o consecuentes  La responsabilidad total de FLIR est   limitada a la reparaci  n  o reemplazo del producto  La garant  a precedente es inclusiva y no hay otra garant  a ya sea escrita u oral  expresa o impl  cita     Servicios de calibraci  n  reparaci  n y atenci  n a clientes       FLIR Systems  Inc   ofrece servicios de reparaci  n y calibraci  n para los productos que vendemos  de Extech Instruments  Adem  s ofrecemos certificaci  n NIST para la mayor  a de los productos   Llame al Departamento de Servicio al Cliente para solicitar informaci  n de calibraci  n para este  producto  Para verificar el funcionamiento y precisi  n se debe realizar la calibraci  n anual  Adem  s  se provee Soporte T  cnico y servicios generales al cliente  consulte la informaci  n de contacto en  seguida     L  neas de soporte  EE UU   877  439 8324  Internacional   1  603  324 7800    Soporte T  cnico Opci  n 3  correo electr  nico  support extech com  Reparaci  n   Devoluciones  Opci  n 4  correo electr  nico  repair extech com  Las especificaciones del producto est  n sujetas a cambios sin aviso  Por favor visite nuestra p  gina en Internet para la informaci  n m  s actualizada  www extech com  FLIR Commercial Systems  Inc   9 Townsend West  Nashua  NH 0
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Olympus Digital Vision software User's Manual  392KB  Plan de cuisson à gaz  Jabra BT5020 User's Manual  Page 1 Page 2 .目 次  PathAway GPS 3 for Windows Mobile  Flush--trimming unit Operating Instructions  Configuración inicial  Samsung DVD-HD935 User Manual  "Voyelles Formations" septembre-décembre 2014    Copyright © All rights reserved. 