1. Figure 8 shows some pictures of the burn in cooling system The thermal control was provided by Huber CC415 circulator 10 controlled through a RS232 interface The parameters of the chiller that suited the needs of the burn in system are shown in Table 1 In order to avoid moisture condensation on the bath surroundings the reservoir was sealed and a nitrogen flow of about 4 5 l h was used to keep the internal environment dry The coolant liquid used is a low viscosity silica oil also provided by Huber Its relevant properties for the burn in operation extracted from the safety data sheet are listed in Table 2 The liquid was cycled in the temperature range between 37 0 C and 30 0 C All safety measures for handling were followed when evacuating the bath container or replacing the thermo fluid 2 The silica coolant type used in the burn in was SilOil M60 115 05 Its specifi cations and safety data sheet can be found at 11 10 cooling block Nes A By we A flexible hoses Figure 8 Four photographs of the cooling system in the burn in setup The top left picture shows the chiller front panel Tubes were connected to the bath to provide nitrogen flow and keep a dry atmosphere On the top right the hoses to conduct the coolant liquid connected at the back of the unit are shown On the bottom left the cryogenic feedthroughs connected to the vacuum chamber lid are shown On the bottom right the flexibl
2. It is a Bipolar CMOS ASIC fabricated in 0 25 um technology designed to be radiation hard It will operate in 40MHz analogue readout mode and trigger rates up to 1 1 MHz can be sustained Technical details on design requirements and specifications are found at 5 The VELO module has a total of 4096 strips with 2048 per sensor The signals are read out from the strips using Beetle front end chips Each Beetle chip reads out 128 strips hence 32 Beetle chips are necessary to read out the module with 16 chips per sensor One single Beetle chip has its readout channels arranged in a set of four ports on the readout multiplexing analogue mode Therefore one port has 32 channels In total 1344 chips will be operated on the 42 modules of the VELO 1 3 3 Hybrid The hybrid is implemented as a flexible kapton circuit which encapsulates a substrate to provide apropriate thermal conductivity to allow the removal of the heat from the front end and sensors The hybrid bulk is an Thermal Pirolytic Graphite substrate TPG wrapped by layers of carbon fibre to provide it with strength and for safe handling The main purpose of the hybrid of the VELO module is to provide electronic support for the sensors The electronic components such as kapton connectors thermistors Beetle chips pitch adaptors are mounted onto the hybrid The bias voltage is also supplied to the sensors via the hybrid In addition it mechanically supports the sensors and minimises material
3. cut the mains power of this in case of a burn in system failure The high voltage unit has a safety loop mechanism to cut off the outputs in case this circuit is opened The safety loop is the standard mechanism offered by the manufacturer and was adopted in the burn in The Iseg HV unit also has a current overflow protection system in its output 4 5 1 Temperature Monitoring The temperatute monitoring interlock protects against any possible overheating of the module This could happen in four situations that were identified during the burn in commissioning All the situations are directly related to the cooling system operation 1 The first possibility is when the chiller continues to function properly but the coolant liquid does not circulate inside the hoses and cooling block It has been observed that water condensation in the surroundings of the bath inside the chiller reservoir can occur since it is not a closed container If this happens some ice is formed in the mixture of the thermofluid and condensed water blocking the normal flow of the liquid through the thin cooling pipe The efficiency of the final module cooling is then drastically reduced and during operation of the chips the module could over heat due to insufficient cooling 2 The thermal connection between the cooling block and the module in the burn in is highly dependent on the cooling block positioning and overheating could also occur if the cool ing block mounting is not do
4. on the analogue receiver side The Telll board can accept electrical or optical signal input cards depending on the sub detector it will read out To perform the main preprocessing of the 1 1MHz LO accepted data the Telll boards have 4 PP FPGAs Pre Processor FPGAs Some of the data processing steps that the Telll can perform on the data from the Beetle chips on the VELO modules are the pedestal subtraction data reordering clusterization Finite Impulse Response filter correction FIR and common mode correction In the burn in lab only the digitised raw data was saved and the processing was performed afterwards The SyncLink FPGA collects the data from the PP FPGAs and assembles the data fragments Then various events are put together into multiple events packages MEP before its transmission to the DAQ network The SyncLink FPGA also distributes the synchronisation signals to the PP FPGAs The data is then delivered to the DAQ network via a Gigabit Ethernet card GBE A Linux machine equipped with a Gigabit Ethernet card is used to acquire the data from the Telll boards and write it in binary files The files are analysed with the Gaudi based Vetra package 22 It is used to perform processing stages such as the pedestal evaluation and the common mode suppression of the data saving the results in ROOT files The final analysis to estimate noise signal to noise and number of bad strips on the silicon sensors is done using ROOT scripts 4 6 2 So
5. screws to allow the cooling cookies attachment For simplicity the modules can be referred to as R glued or glued because they can either have the R or side of the hybrid glued to the paddle The module in figure 1 is a glued module The paddle is made of a low mass carbon fibre piece attached to a carbon fibre base 1 3 1 Silicon Sensors The LHCb VELO sensors are 300 um nt on n oxygenated silicon They were optimised for long term operation under the LHCb radiation environment The maximum fluence rates on this non uniform environment were estimated to be 1 3x10 n q cm per year The VELO module should operate over a minimum period of 3 years at the nominal luminosity of 2 x 10 em 7s As already mentioned there are two different patterns of strips on the silicon sensors of the VELO modules The strips on the R sensors have annular shape with length increasing from 4 0 mm to 34 0 mm from the innermost region to the outermost region respectively The inner strip pitch size varies from 40 um to 92 um The strips are set in an arrangement of 4 sectors Each sector has the same size and contains the same number of strips The strips on the sensors have a radial geometry and are divided in inner and outer strips The length of the inner and outer strips are 9 3 mm and 24 9 mm respectively The pitch size on the sensors vary between 37 um and 98 um 1 3 2 Beetle Chips The Beetle chip is a readout device for silicon strip detectors
6. to determine the position of the primary and secondary vertices in the observed events The VELO system is composed of a series of silicon detectors stations placed along the beam direction There are two halves of the VELO detector Each half contains 21 modules The nominal distance of the sensors to the beam during operation will be 7mm The halves can sensor me Kapton l connectors js a Figure 1 A photograph of a glued LHCb VELO module and its components be retracted during LHC beam injection by 30 mm each side Each module has two sensors back to back The sensors are strip detectors with a half disk shape The strip pattern depends on the kind of measurement that the sensor performs It can be an R or measurement and every module contain both types of sensors The modules have an angular coverage of 182 perpendicular to the beam 1 3 Module Description The VELO module is composed of two silicon strip detectors attached on a hybrid which is glued to a carbon fibre support paddle 4 Figure 1 shows the sensor of a production module The electronic components are also mounted and connected on the hybrid The charge readout of each sensor is performed by 16 Beetle chips 5 whose location is indicated in Figure 1 The kapton cable connectors and negative temperature coefficient thermistors NTCs on the hybrid are also shown in Figure 1 The cooling interface where the hybrid is glued to the paddle has 5 captive
7. to perform resistance measurements one could record the settings on disk and load it again afterwards The data display application allowed graphs of the monitored parameters to be displayed as a function of time For each parameter it was neccessary to set up the eletronic channel used to read out the device and a suitable calibration An example is the calibration required to obtain temperatures from an NTC probe To monitor a given NTC it was necessary to set the channel number of the Keithley multimeter which was connected to the NTC and the calibration that should be used Then the channel configuration and corresponding calibration could also be recorded in XML files 4 5 Interlock System The modules were protected by a hardware interlock system against any malfunction of the burn in system that could harm their physical integrity Interlocks were developed for moni toring the temperature on the hybrid and the pressure inside the tank the protected parameters were the high voltage and low voltage The burn in interlock had two monitoring units in order to turn off both high voltage and low voltage supplies in case of a system failure As mentioned in Section 4 3 an Agilent E364BA unit was used to power up the Beetle chips with 3 5V and an Iseg GCH 224L unit provide the high voltage applied to the silicon detectors The Agilent unit can not be turned off via an external signal but only manually or via software commands Hence it was decided to
8. visual inspection setup It consisted of fine integrity verification of all the module components Some examples of typical problems that can be found with the microscope such as lifted bonds and defects on the pitch adaptors are also shown in Figure 4 After the completion of the burn in test a second visual inspection was done in order to verify if any changes have happened during the period of tests 3 1 Module Handling An important aspect of the system was enabling the safe handling of a VELO module through out the different stages of testing A frame was designed to incorporate the following points as well as being compatible with the burn in setup e Easy and safe mounting and dismounting of modules to the frame e Thin enough for the module to be placed underneath the visual inspection microscope e Allow access to either the R and faces of the module during visual inspection and burn in e A mounting system compatible with the standard connections on the feet of the module to Minimise unnecessary stresses Removable bridge frame i m4 screws protection Transfer jig gi gp Figure 5 An LHCb VELO Module mounted in the mechanical frame on the transfer jig The frame designed to meet all of these requirements is shown in Figure 5 together with the transfer jig The transfer jig was employed to transfer modules to and from the frame in a safe manner The diagram shows how the sides of module frame ca
9. 2 Overview The VELO modules are comprised of a number of different materials with different physical properties and the functionality of the active components need to be tested under long term operation For example latent defects can be hidden in its components or be introduced during its assembly Any dynamic component can also suffer from infant mortality which refers to the malfunction of the component after a short time of operation The long term testing and stressing under realistic environmental conditions is one way to detect faulty components that can result in the compromise of the long term operation of the unit The faulty components can then be fixed or replaced Verifying the long term operation of each VELO module is a primary concern due to the harsh and inaccessible environment that it operates in and the loss of coverage the vertex de 3 tector could suffer as a result of a malfunctioning unit The main aspects to be covered by the long term stressing are the operation under vacuum the temperature cycling the module will be subjected to and any infant mortality that the electronic components may suffer A number of guidelines have been developed from experience to perform long term testing that results in improving the long term operation of the unit Documents 6 7 describe guidelines for similar applications these were used in determining the procedure for the VELO module tests The other aspect that can affect the long term
10. GLAS PPE 2007 08 Department of Physics amp Astronomy 74July 2007 Experimental Particle Physics Group aioe RSIEY Kelvin Building University of Glasgow of Glasgow G12 8QQ Scotland GLASGOW Telephone 44 0 141 339 8855 Fax 44 0 141 330 5881 A facility for long term evaluation and quality assurance of LHCb Vertex Detector modules F Marinho A Bates R Dimattia F Doherty R Dumps M Gersabeck J Melone C Parkes A Saavedra M Tobin Corresponding authors The University of Glasgow Dept of Physics and Astronomy gt European Laboratory for Particle Physics CERN University of Liverpool Dept of Physics d Now at Sidney University NSW Australia Abstract This note describes the facility developed for long term evaluation and quality assur ance of the LHCb Vertex Detector modules known as the Glasgow Burn in System This facility was developed to ensure that the modules conform to stringent quality levels The system was able to uncover any weaknesses that could be introduced during the manufac turing and assembly of the components or during the transport of the modules to CERN The system consisted of a high resolution microscope for visual inspections and a burn in system to operate cooled modules in vaccuum The main components of the burn in system were a vacuum system a cooling system and a DAQ system 1 Introduction The aim of this note is to describe the system developed to exercise L
11. HCb VELO modules under realistic conditions for long periods of time This is colloquially referred to as the burn in of the module The aim of the Glasgow burn in system is to uncover any weaknesses introduced into the modules during manufacturing or in the components themselves The system is able to verify that all the modules which are tested conform to a certain level of quality The LHCb modules were produced at Liverpool and then transported to CERN where they were received visual inspected and tested in the burn in setup This document is divided into a number of sections detailing these tests and describing each sub system s purpose construction and performance An overview of the laboratory area and discussion of the tests performed is given in Section 2 The different aims of these tests are also explained Section 3 describes the hardware equipment used on the reception and visual inspection in more detail It also lists all the items verified on the modules Section 4 describes the burn in setup and its components Each of the burn in components is described in separate sub sections of Section 4 where details on the construction and performance are given The burn in sub systems were used together to replicate the environmental conditions of the experiment and to operate the modules Section 5 concludes the report by providing an overview of the performance of the system and commenting on how the environmental conditions of the experiment we
12. and the module a thin plastic layer was kept in between removing this layer would improve the thermal conduction however it would need to be checked that his pad did not leave a sticky residue on the modules Four PCB cards were used to supply the modules with low and high voltages The PCBs were placed in the lid of the vacuum chamber and sealed with Variant Torr Sealant Inside the vacuum chamber short kapton cables were used to connect the the PCB cards to the mod ules As PCB cards are quite fragile the procedure of attachment of the short kapton cables was difficult and could potentially break one of the cards Fortunately no such problem occurred during the burn in operation However the replacement of one of these PCB cards and installa tion in the chamber lid would be time consuming An additional mechanical support could be manufactured in order to avoid stresses on the PCB cards during the kapton cable attachment The monitoring software used was satisfactory for the burn in purposes but its operation was temperamental and its full capabilities were not explored yet So far a number of temperatures and the high voltage were measured using the software algorithms However algorithms were also developed to measure the pressure low voltages and currents and address the software sta bility issues This second version of the software was not deployed during the burn in operation as the continuity of operation was considered to be more importan
13. con sensors is not yet well defined but the pressure value of 1 x 1074 mbar was set as a minimum value for the safe operation of the modules above 100 V in the burn in The Controller 201 unit in the vacuum system provided a set of 3 output relays Two of them gives one output ON OFF and the third provides two outputs ON OFF amp OFF ON A voltage of 5 V was connected to one of the relays in order to provide a step signal in case the pressure goes above a certain threshold range of pressure A few situations where the pressure interlock system should take action were identified during the burn in setup commissioning All were directly related with the functioning of the vacuum pumps since all the potential air leaks were eliminated during the burn in commissioning The most probable is when the power supply of the vacuum system is off due to excessive power demands In this case the relays in the pressure interlock system are triggered immedi ately and not when the pressure reaches the maximum pressure level allowed for operation The relays are used to interrupt the power supply to the high voltage and low voltage systems as described below The less probable cases would be of proper degradation of the vacuum making the turbo pump turn itself off This could happen due to outgassing of the plastic arm that supports the module frame or for example some small piece of kapton tape that could be released and dragged into the vacuum tube causing a bl
14. cuum chamber while in contact to an internal liquid cooling circuit Achieving the vac uum and module cooling was only part of the challenge The module handling the monitoring of the environment module parameters and interlocks to ensure safe module operation were all aspects of the burn in system that also required development for the long term testing to be performed The purpose of each system together with its description follows 4 1 Vacuum System The burn in of the LHCb modules is only fully effective if the operational environment in the experiment is approximately recreated during testing Hence in order to evaluate the function ing of the modules a vacuum system was constructed A vacuum environment was needed not only to mimic the experimental conditions but also to allow the operation of the modules with the same parameters as on the experiment To safely apply the bias voltage default on the sensors it was necessary to have the module at very low pressure condition to avoid any discharge Studies performed on the burn in system have shown that discharges don t occur at atmospheric pressure or very low pressure conditions but a mid pressure range should be avoided 9 The heating and cooling of the module could be performed when the module was in vacuum with no concerns of the formation of condensation on the surface of the module The burn in vacuum system consisted of a vacuum pump setup and stainless steel chamber The vacuum pum
15. e hoses and cooling block located on the opposite side of the lid can be seen 11 Table 2 Silica coolant liquid specification parameters Boiling point 300 C at 1013 mbar Density 0 923 g cm at 25 C Vapour pressure 0 01 mbar at 20 C Kinematic viscosity 5 mm7 s at 25 C Heat capacity 1 63 J g x K Thermal conductivity 0 133 W K x m Solubility in water insoluble Flash point DIN 51376 gt 120 C Ignition temperature DIN 51794 gt 400 C The unit does possess a number of hardware alarms such as low or high fluid level in its bath overheating and malfunctioning Given the small volume of coolant liquid necessary and temperature requirements for the burn in operation it was possible to set all the safety parameters to values even more stringent than those proposed by the manufacturer These values were also chosen in order to fully satisfy the coolant specifications In the situation where one of these hardware alarms was triggered the chiller unit turns off its cooling and stops pumping the coolant liquid through the cooling system If the module was to over heat after a cooling system failure then the burn in interlock system is triggered and the module voltage supplies are turned off More details on the burn in interlock system are discussed on Section 4 5 The coolant was conducted to the vacuum chamber via insulated hoses that were connected to the cryogenic feedthroughs on the lid of the vacuum chamber The feedthroughs mak
16. e temperature was obtained by converting from the resistance read on the NTC on the module The resistance input connectors were also located at the front panel of the unit At the back of the device a set of two 230 V plugs INPUT OUTPUT and 2 banana plugs INPUT OUTPUT were available to connect the Agilent and Iseg devices The unit supply cable was also connected at the back 19 metallic box Figure 12 Temperature interlock schematic and pictures of the unit The input signal was the resistance read from one NTC on the hybrid The current temperature was shown in the front panel display The unit used two relays to interlock both high voltage and low voltage units On the back panel the HV safety loop and Agilent power cable were connected If a module overheats both connections are opened and the module power supplies are turned off 20 Table 4 BROICE relay parameters list Parameter Values Input voltage range 0 5 10 0 V 3 0 60 0 V 30 0 600 0 V Over voltage 0 100 Hysteresis 5 50 Time delay 0 1 3s Reset time 60 ms Latching facility selectable Relay inversion selectable In normal operation the temperature interlock unit had the HV safety loop and the power supply cables of the low voltage connected When the temperature interlock detected an abnor mal temperature on the hybrid the connections were opened and the modules power supplies were turned off The functioning of the temperature interlock unit was te
17. e the connection between the external part of the cooling system and the flexible metallic hoses at tached to the cooling block inside the vacuum chamber The cryogenic feedthroughs were required to minimise the thermal conductivity between the hoses carrying the coolant and the chamber lid Two triple insulated hoses of 1 5 m length were the most appropriate tubing choice to con duct the coolant from the chiller to the vacuum chamber The hosing operational temperature range is between 100 0 C and 200 0 C The fittings are female M16 x 1 External and internal diameters are respectively 42 mm and 10 mm The insulating layers used are glass silk 3 mm thick silicon foam tubing 6 mm thick and a black poly braiding cover An external layer of rubber insulation was also added to the tubes in order to reduce the heat loss as much as possible To connect the hoses to the swagelock fittings of the tube of the cryogenic feedthroughs a M16X1 to 3 8 inches adaptor was installed between them The feedthroughs were connected to flexible metallic hoses inside the chamber with swagelock fittings The flexible hoses can be bent with a minimum radius of 4 0 cm in dynamic applications In the burn in system the radius was estimated to be bigger than 5 0 cm and it is a quasi static application On the other extreme of the flexible hoses the cooling block was attached as shown in Figure 9 The length of the tubes has been chosen such that low stress was applied
18. ed in an aluminium frame with clear plastic covers on both sides Figure 4 shows the visual inspection 1 A transportation box was developed for the transportation of the modules 8 4 see e 8 Communication Lines Cooling Block meal ybrid Sensor Li Control meal Analysis ll First Module PC Short Kapton Cable Cooling System Alarms Vacuum Pump System Hardware HV and Low Interlock Al Supplies Cuts HV and LV to module VeLo Module Thermal Vacuum emperature urn in One Chamber Figure 2 The burn in setup is composed of vacuum system cooling system interlocks DAQ system low voltage supplies high voltage supply and 2 PCs to control monitor and perform data analysis A C Desktop PC s Visual Inspection Figure 3 The burn in area layout On the left side the visual inspection microscope the data analysis PCs and the DAQ hardware are shown On the right side the cooling system the vacuum system and reception area are shown Lifted bonds Ota Mi wet ide Figure 4 A Lynx microscope equipped with coolpix camera is used to perform the visual inspections On the left side a module is mounted on the visual inspection frame Various items are verified on the visual inspection Problems as the lifted bonds and defects on the pitch adaptors seen on the right hand side picture are typical problems that can be found during the
19. ed using the burn in vacuum system but also without a module mounted The pumps were turned off and the pressure hardware interlock relays opened their electrical contacts for the low voltage and high voltage as expected 4 6 Control and Data Acquisition The data acquisition setup DAQ used in the burn in lab was able to fully operate the electronics of the module and acquire data from both sides of the module simultaneously inside the vacuum chamber This DAQ electronics was quite similar to the ones that will be used in the final 21 Agilent 240 V a Safe metallic box 0 5V Broice unit Broice unit Figure 13 The top picture shows the pressure interlock schematic The input signal was the 0 5 V delivered by the Controller 201 unit in the vacuum pump system It used two relays to interlock both high voltage and low voltage units The state of the relays can be verified from the LEDs on the front panel The overvoltage and hysteresis are tuned on the front panel buttons On the back panel the HV safety loop and Agilent power cable are connected 22 Readout supervisor Odin TTC signals Data stored Tell 1 Control board Linux machine Data acquired Repeater boards Signals sent to beetles Figure 14 Diagram of the DAQ system in the burn in The readout supervisor sends TFC signals to the Beetle front end chips in order to configure them The data acquired is received and digitised by the Telll boards a
20. edure The burn in frame sits in a plastic cantilever attached to the vacuum chamber lid This plastic piece is suitable for vacuum applications and prevents heat flow from the lid to the frame The cooling block was attached to the frame using plastic L shapes to reduce the heat flow from the frame to the cooling block A support at the opposite side was used to attach the cooling connection and position the cooling block correctly Additional clamps were attached to the flexible tubes to avoid the mechanical stresses that could happen due to thermal expansions or contractions during the temperature cycles To achieve the required temperature for the thermal cycling the circulator was operated at 38 C The cooling block temperature at this point achieves a minimum of 30 C with and without a module mounted No significant temperature difference was observed when the module low voltage was switched off The minimum temperature measured on the hybrid with the readout electronics off was between 20 C to 25 C showing that the cooling system was capable of thermally stress the modules The cooling system was able to vary the temperature of the module hybrid from 30 C to its minimum in about 20 minutes It allows the burn in system to thermal cycle the modules in temperature ranges compatible to those in the experiment 4 3 Voltage Supplies and Monitoring Devices There are a number of voltages that are required by the VELO module to be fully ope
21. ented Data Analysis Framework http root cern ch October 2005 14 QTROOT Qt Interface to ROOT http wwwlinux gsi de go4 qtroot html qtroot html December 2005 15 CAREL Via del Industria 11 35020 Brugine Padova Italy Universal Infrared Series user manual 16 BROICE Broyce Control Ltd Pool Street Wolverhampton West Midlands WV2 4HN England 45050 voltage relay instructions 17 Readout Supervisor design specifications LHCB 2001 012 28 18 Control and Monitoring of VELO and Pile Up Level 0 Electronics EDMS 596194 19 Telll Specification for a common read out board for LHCb LHCb 2003 007 20 The LHCb Timing and Fast Control System LHCb 2001 016 DAQ 21 SPECS the Serial Protocol for the Experiment Control System of LHCb LHCb 2003 004 22 Vetra Gaudi application for Velo data decoding http ppewww physics gla ac uk LHCb Simulation velosim html July 2007 23 PVSS Introduction for Newcomers http itcobe web cern ch itcobe Services Pvss Documents PvssIntro pdf August 2006 24 Distribution Information Management System http dim web cern ch dim August 2006 29
22. es during the tests is ensured by a hardware interlock system monitoring both pressure and temperature of the module 6 Future Improvements A facility for the long term evaluation and quality assurance of the LHCb VELO modules has been designed commissioned and successfully operated No significant failures occurred during the complete testing of all the production modules and all the procedures went smoothly The only failure during operation was of the rotary pump which was replaced It is planned that a replacement set of sensors will be produced for the VELO This section describes recommended changes to the burn in facility for the testing of these future sensors These improvements can be implemented in order to increase the reliability of the system and extend the range of tests that can be performed In addition some elements such as the vacuum system should be serviced again before long term operation The main possible improvements are related to the cooling system the fragile PCBs installed on the vacuum chamber lid and the operation of the monitoring software The cooling system was capable of keeping the modules at a safe and stable temperature level However the minimum temperature that was reached was strongly dependent on the mounting procedure of the cooling block on the module Improving the flatness of the cooling block would allow a better thermal interface with the module A thermal gel pad was used between the cooling block
23. eveloped to allow the modules to be operated under the required environmental conditions Satisfactory performance of these components has been achieved such that the VELO modules can be operated according to the requirements specified for the burn in tests The vacuum system consists of a set of vacuum pumps and a vacuum chamber The obtained values of pressure obtained in the burn in setup are adequate to test the module in a environment similar to the LHCb experiment The system achieved pressure levels of the order of 5 10x10 mbar within a period of 20 to 40 minutes Running overnight values of about 0 5 1 x 10 mbar were reached The cooling system was designed to provide appropriate heat transfer from the module to the coolant liquid used The critical part of the design of this system is the cooling block A set of mechanical constraints lead the cooling block to be a two piece cooper pipe connected by a U tube This connection allows the cooling pipe to expand and contract according to the temperature changes without applying mechanical stress on the module The final cooling block is able to cool down a mounted module from 30 0 C to 20 0 C in about 20 minutes A similar period of time is taken to bring the module temperature up again The burn in DAQ system has been used to acquire data from the modules It can read out both sides of the module simultaneously using two Telll boards To set up the correct chip configuration a control boa
24. f the cooling block was mainly limited by the area of the module thermal interface The size of the cooling block was also constrained by the distance between the module kapton cables and the module thermal interface Figure 10 shows a 3D diagram of the cooling block attached on a module mounted on the burn in frame The cooling block was composed of a copper pipe and two aluminium blocks as indicated in Figure 10 The aluminium pieces make the connection between the metallic flexible tubes and the copper pipe closing the circuit where the coolant liquid flows inside The design of the cooling pipe with two flat pieces connected by a cooper U allows the block to slightly deform due to temperature variations without applying any mechanical stress on the module The two copper flat pieces were made of 6 mm copper blocks machined out and lids attached with high 13 temperature braising This avoided any leaks while operating at low pressure Thermal film COH 4000 with 0 5 mm thickness was used as a thermal interface to attach the copper pipe to the module cooling face The film interface improves the thermal connection filling the small gaps due to the cooling block surface irregularities Its low outgassing properties were compatible with the system Figure 10 shows the cooling block installed on the chamber lid and also attached to one of the modules The module was placed in the burn in frame which had a hood to protect the silicon sensors during the proc
25. ftware The software panels to control the hardware in LHCb are made within the PVSS framework 23 It is an application that allows the development of supervisory control and data acquisition systems SCADA It has been used in the LHC experiments and is widely used on industrial applications to control distributed system from a master location In LHCb it is used to access the DAQ hardware slow controls such that it can be initialised configured and operated It can connect to the hardware devices acquire data and monitor their behaviour The communication between the PVSS applications and the CCPCs in the burn in lab are done with the client server paradigm These applications allows the user to initialise and operate all the boards in order to run the data acquisition system Hence the VELO modules operation is also controlled by the system user via the PVSS applications The credit card PCs CCPC runs a server while the PVSS applications run clients By means of the client the application demands the server to execute some task it can perform according to the functionality it has implemented To perform the FPGAs programming directly a generic server is available on the CCPCs It is referred to as the DIM server since it was implemented with the Distributed Information Management package 24 To operate the whole DAQ system a set of servers has to be initialised To set up the Odin 25 one has to start its server and depending on the type
26. ked before assembly This cleaning procedure has been repeated a few times for the plastic pieces of the mechanics e Gloves were always used when handling anything that was to be placed inside the vacuum and measures were taken to keep the vacuum tank clean The operation of the vacuum system with its mechanics inside the chamber has achieved appropriated vacuum quality and stability The rotary pump sustained the secondary vacuum at levels of 0 1 Torr after 10 minutes of operation The turbo pump reached levels of 5 10x 107 mbar after 20 40 minutes of operation on the primary vacuum Pressure values of the order of 0 5 1 0x10 mbar were obtained after overnight runs No quality degradation of the vacuum or turbo pump failures was observed during the assembly and test phases 4 2 Cooling System The VELO cooling system has been designed to keep the silicon detectors in a temperature range of 7 0 C to 5 0 C while the temperature of the Beetle chips and other electronics components should be kept below 40 C To mimic the environment in the LHCb experiment a cooling system was set up in the burn in lab It was meant to control the temperature of the modules and to perform thermal cycles in order to stress them thermally and mechanically The cooling system developed for the burn in consisted of a chiller insulated hoses cryo genic feedthroughs flexible metallic hoses and a custom designed cooling block that was at tached to the module
27. m chamber On the right hand side picture the control panel is shown To provide the appropriate vacuum environment to operate the VELO modules any leak on the vacuum system connections should be avoided and the outgasing of the components used inside the vacuum should be minimised A set of measures were taken in order to achieve the desired vacuum quality e The additional mechanics and electronic components used inside the chamber were suit able for high quality vacuum applications vacuum chamber Ex s ball valve iN Pi mom c io iS i he gt AT mechanical support Figure 6 Picture of the stainless steel vacuum tank Its dimensions are 40 cm diameter and 60 cm length The tubing has 40 mm diameter and a 1 m length A set of valves were installed to facilitate the vacuum operation procedures turbo pump turbo controller T Figure 7 Three photographs showing the vacuum pump system The left hand photograph shows both pumps and their respective accessories The centre photograph shows the turbo pump and its connections The right hand photograph shows the control panel Table 1 The specification parameters for the Chiller Temperature range 40 C 200 C Cooling power 50 W at 40 C 200 W at 30 C Heating power 1 5 kW Maximum power 2 5 kW Control Interface RS232 RS485 via CC3 Tubing connections male M16x1 e All the mechanics pieces were properly cleaned in a ultrasound bath dried and ba
28. monitored voltages are digitised on the control board and sent to the experiment control system ECS The repeater board acts as a signal amplifier of the TFC and configuration commands from the control board as for the data signals read from the detector front end The control commands to the repeater boards are sent only by the control board It also contains drivers and multiplexers for the monitoring signals The monitoring signals are of two types temperature monitoring signals and voltage monitoring signals In the LHCb experiment the monitoring signals will 24 be routed either to the so called temperature board or to the control board The temperature monitoring and interlock of the modules and repeater board will be made by the temperature board However in the burn in system the temperature monitoring is performed using a Keithley and the temperature interlock done by a custom made unit see Sections 4 4 and 4 5 A FPGA based acquisition board was developed for the LHCb experiment The so called Telll board is used on all sub detectors in the experiment Its design and functionality is con strained by the maximum LO output event rate of 1 1MHz Its makes the interface between the sub detectors front end electronics and the DAQ network It can also perform basic data preprocessing The Telll works as a receiver card of the front end electronics signals On the VELO such data is delivered via analogue electronic signals which are digitised
29. n be removed allowing the module to be easily mounted or dismounted on its base as it is held by the transfer jig The R and faces of the module were protected by clear plastic panels that were removed during visual inspection A similar aluminium frame was used to place the modules into the burn in vacuum chamber It had the same dimensions as the one used on the visual inspection but modifications were made in order to satisfy the mechanical requirements Details on the burn in system are given in Section 4 4 Burn in Setup The most important design consideration of the VELO was to optimise the impact parameter resolution of the reconstructed tracks This was achieved by keeping the material to a minimum and by placing the sensors as close as possible to the interaction point The first condition results in the modules being operated under vacuum in order to get close to the beam The second condition results in high levels of radiation being incident on the sensors during operation The sensors were designed to withstand high levels of radiation In order to minimise the effects of radiation damage the sensors are kept at temperatures around 5 7 C This condition implies that during the lifetime of the modules they will undergo a large number of temperature cycles as either the cooling or its front end electronics are switched on or off These two features were recreated in the burn in by operating the modules inside a stainless steel va
30. nd then stored in binary files in a Linux machine experiment Figure 14 illustrates how the DAQ used in the burn in was set up The Odin readout supervisor was responsible for the control of the modules readout 17 It was done by sending TFC signals to the control board 18 and Telll mother boards 19 The control board sent these signals to the Beetle chips in the modules via the repeater boards in order to configure and operate them The data acquired was sent back to the Telll boards passing through the repeater boards The Telll boards digitise the data and it was finally acquired by a Linux machine by means of Gigabit Ethernet cards The Linux machine saved the data in a binary file for further analysis 23 Odin ctrl board 2Telliboards 2 repeater boards 8 data cables 2 control cables m SY f 3 TTC fibres A Figure 15 The DAQ setup in the burn in system 4 6 1 Data Readout The DAQ hardware consists of two Telll mother boards two repeater boards one control board and one Odin readout supervisor The Tell1 mother boards control board and readout supervisor were located in a single crate The repeater boards were placed close to the chamber lid Figure 15 shows the setup The Tell1 boards are connected to the repeater boards via 8 data cables each 5 m long Two control cables connect the repeater boards to the control board and each cable is 20 m long To connect the repeater boards to the hybrid fou
31. ne properly such that its surface is not fully attached to the 17 module thermal interface However this problem would be rectified since it would be no ticed and corrected during the start up of the burn in procedures and before the interlock being triggered 3 The third situation is when the chiller mains could be turned off due to the chiller draw ing more power than that specified as maximum for operation or due to the mains fuse blocking if the drawn current is too high The maximum current allowed in a standard fuse for mains is 10 A and the maximum current operation of the chiller is 11 5 A 4 Human error could also lead the interlock system to trigger if the module is turned on with the cooling system off or set up to run in a non safe temperature level In each of these three scenarios the module temperature would rise and at a hybrid temperature of 50 C both the low voltage and high voltage would be turned off thereby reducing the temperature of the module 4 5 2 Pressure Monitoring Monitoring of the pressure was necessary since a vacuum system failure could cause a raise in the pressure inside the chamber while the module was operated in high voltage and at low tem perature conditions In this case condensation could occur over the silicon surface and electronic components of the modules if they were operated at low temperatures in an air environment The pressure level for operation of the high voltage applied on the sili
32. ockage In these cases since the gauge unit was completely independent of the turbo pump the relays would change their state if the pressure readings passed the maximum level allowed 4 5 3 Interlock Unit Devices The burn in system had two independent devices to protect the modules in case of failure which were a temperature unit and a pressure unit They worked in a series arrangement such that the 18 high voltage and low voltage supplies would be turned off both in the case of the temperature passed certain limits or the pressure was bove the acceptable threshold Figure 11 shows a diagram of the interlock system 240 V 24V 6mA Temperature interlock unit Pressure interlock unit Low voltage High Voltage Agilent Iseg Figure 11 Interlock diagram It uses two units to protect the module inside the chamber The arrangement of the interlock units ensure that high voltage and low voltage will be turned off in case of a system failure Temperature Interlock Unit To protect the system against overheating accidents a temperature monitoring device was built It uses a regulator CAREL IR32 15 with a resistance input It is simple to program and has a set of prearranged functions that allow operation in different modes parameter values and calibration offsets Figure 12 illustrates how the unit was set The front panel of the unit shows the current hybrid temperature and the working parameters were set on the front panel Th
33. of task it will perform different recipes are loaded The Odin server runs automatically In order to operate the control board correctly the Specs server have to be running properly In the final experiment the Telll boards will also run servers but up to now it has been operated by direct Linux commands in the burn in lab 5 Conclusion A facility has been developed and commisioned to perform the reception visual inspection and burn in of the VELO modules The reception and visual inspection checks aim to verify the physical integrity of the modules on their arrival and after the burn in tests The burn in setup can be used to perform a long term evaluation of the modules in environmental conditions similar to those in the real LHCb experiment The modules are thermally stressed in order to uncover any latent weakness intrinsic to the components of the module or introduced during the assembly phase Procedures and suitable mechanics have been developed for the safe handling of the modules during reception and visual inspection A transfer jig and an aluminium frame with a base compatible with the module attachment points have been made When the module is mounted on this frame transparent plastic plates are used to protect the module The frame fits safely under the microscope to allow visualisation of the different elements of the module The burn in setup is composed of vacuum cooling DAQ interlock and monitoring systems These components were d
34. on is requested by the user the system class gives the updates to the monitoring thread that runs independent of the GUI and communicates with the hardware via the device class To avoid conflicts when accessing memory the system class locks the addresses where the new command information is written to disable the thread from trying to access the same address at that time After the information is updated the memory location is unlocked The device class was implemented with all the functionality provided by the drivers in a user friendly manner and tuned to the operation of the devices used in the lab Once the hardware status is obtained the information is written back and the system class is notified that there is data to be updated via a posted event by the thread If required the data is passed to the GUI by the system class The System class also writes the data in a memory address shared with the data display software It uses the signal slots mechanism to notify the data display that there is more data available to be added to the graphs 16 Additional features were implemented using ROOT I O classes The application controlling devices were able to save acquired data in ROOT files for further analysis Configuration files to operate the devices could be saved in XML files For example the files were saved for the Keithley controller used to read out the NTCs on the module and cooling block After all the necessary channels used were configured
35. operation of a module is any physical damage that the module could suffer due to handling at the assembly stage during transportation or test ing The damage can range from subtle effects such as misshaped wire bonds to serious damage such as chipped or scratched silicon sensors The modules were transported from Liverpool the assembly site to Geneva where they were integrated into the VELO detector The modules were received at the Glasgow test facility at CERN using procedures designed to verify the in tegrity and quality of the delivered modules These tests consisted of a visual inspection using a high resolution microscope and a burn in procedure The aim of the inspection was to verify the physical integrity of the module after trans portation It consisted of a high resolution visual inspection over all the bonds components and silicon on both sides of the module for any visual signs of damage Electronic components were verified Photographs of the modules may be taken for later analysis if necessary The kapton cables were shipped with its corresponding module and were also inspected The burn in system was used to perform a series of tests to stress the modules when func tioning in similar conditions to its normal operation in the experiment It has been built to perform periodic thermal cycles while the modules are operated as in the real experiment To reproduce such conditions the modules have to be enclosed in a vacuum chamber and it
36. p system is based on the traditional arrangement of rotary pump and turbo pump The turbo pump model was a Pfeiffer TPH 330 and the rotary pump was a Pfeiffer DUO 012A Additional mechanics were developed to locate the module safely inside the vacuum chamber Figure 6 shows the vacuum tank Its has a diameter of 40 cm and length of 60 cm Con nection to the vacuum system was done through the back of the tank A diaphragm valve and an air inlet valve were attached in a 40 25 mm reducing tee connection which allows air to be released inside the tank when tests were finished A 40 mm ball valve was installed to close the connection between the vacuum pumps and tank The diameter of the flexible hose is 40 mm and it has a length of 1 m Figure 7 shows the vacuum pump system in the burn in lab The picture at the left side shows the pumps inside the plastic box used to isolate the system from the clean room since the pumps were not rated for class 100 000 clean rooms The rotary pump had its exhaust connected to outside of the clean room because of the toxic and contaminating nature of its gases In order to avoid any oil reaching the vacuum chamber a foreline trap was placed between the rotary and turbo pump In the centre photograph in Figure 7 the header vessel mounted on the turbo pump is shown It has one 25 mm connection to a vacuum pressure reading penning gauge and four 40 mm connections available One was used to attach the flexible hose to the vacuu
37. r pcb patch cards are plugged on the lid of the vacuum tank and sealed on the outside and inside of the chamber Between the pcb patch cards and repeater boards there are 8 flat 50 pin cables 10 cm long with strain relief connectors Finally the modules kapton cables are connected directly to the patch cards In the LHCb experiment the timing and fast control TFC distributes the information that has to arrive synchronously at different points of the experiment 20 The readout supervisor is the component of the LHCb TFC that is responsible for the distribution to the front end electronics of the timing trigger and control commands necessary for the synchronous readout It also acts as trigger rate controller avoiding buffer overflows using the status of the different components of the system The control board receives the timing signals and fast commands from the Readout Super visor and distributes them to the Level O electronics Each control board can support up to 6 VELO modules The configuration data on the control board are translated and distributed to the configurable components via I C by the Specs Slave on the board 21 Specs is a 10 Mbit s serial link based on master multi slave paradigm designed for the configuration of remote elec tronics elements It is used to read the configuration of the electronics located on the detector It allows fast efficient and error safe communication between electronic elements On the ex periment the
38. rated For nominal operation a module requires 24 5 W A set of electronics devices were used to supply the electronics with appropriate voltages currents and to read out the NTCs mounted on the modules hybrid repeater boards cooling block and vacuum chamber walls To supply the modules with low voltage and high voltage two component units were used An Agilent E364BA was employed to supply two channels for the module low voltage Each channel was used to supply 16 Beetle chips on each side of the module Each Beetle chip was powered with 3 5 V and consumes 0 22 A An 8 channel Iseg GCH224L unit provided the bias voltage to deplete the module sensors Each sensor was biased by an individual channel The voltages were supplied to the module via the repeater boards The repeater boards are the components of the burn in DAQ which not only serve the modules with the voltages but also drive and amplify the read out signals More details on the DAQ electronics on the burn in is given in Section 4 5 A second Agilent E364BA was also used to power the repeater boards themselves A chan nel was available on each of the two repeater boards used To monitor the NTCs on the mod ules hybrid repeater boards cooling block and vacuum chamber walls a Keithley multimeter equipped with two cards of 20 and 40 channels was used The resistances of the NTCs were measured and the temperatures were calculated using the manufacturer s calibration formulas The Iseg uni
39. rd is used Repeater boards are necessary to shape and amplify the signals read out from the Beetle chips and serve the modules with voltages and currents The acquired data is digitised by the Telll boards and them saved onto disk using Gigabit Ethernet cards to transfer the data to the Linux machine available in the lab Afterwards the data is stored and can be analysed with the data analysis software that has been developed A set of possible failure modes were identified in the burn in system and to protect the modules against any possible malfunction an interlock system was developed It consists of two units which are used to monitor the temperature of the modules inside the tank and the pressure 26 If a failure in the cooling system causes overheating the temperature hardware interlock will shut down the low voltage and high voltage supply to the module If the vacuum system stops pumping down raising the pressure then the pressure hardware interlock units will also turn off the module The Glasgow burn in facility has been commisioned and achieved the requirements neces sary to allow the testing of the VELO modules suitably replicating the LHCb environment The vacuum system provides the low pressure needed within a reasonable time scale The cooling system is able to thermal cycle the cooling block and control the hybrid temperature A DAQ system to readout both sides of the module simultaneously has been operated The safety of the modul
40. re replicated The analysis and results obtained on the testing of the modules in the burn in facility are presented in a second note 1 1 1 LHCb The LHCb detector 2 is an experiment primarily designed to study CP violation and rare decays studies in the b hadron sector It is essential for these investigations that the detector reconstructs the particle tracks to a great precision inside its volume and locates the primary interaction and decay vertices The vertex reconstruction is performed by the Vertex Locator of the experiment The detector was designed to reconstruct the position of the vertices with high precision For primary vertices the resolution is about 42 um in the beam direction z axis and 10 wm in the transverse plane xy plane Such measurements are necessary for accurate calculations of the lifetime and impact parameter of the b hadrons The resolution for decay length ranges from 220 um to 330 um depending on the decay process of interest An impact parameter resolution of 20 um is expected for those tracks with higher values of transverse momentum gt 10 GeV c 1 2 Vertex Locator For this experiment the VErtex LOcator VELO 3 plays an important role It will make precise measurements of the coordinates of the tracks close to the interaction region The VELO covers not only the angular aperture of the LHCb spectrometer but also has limited coverage in the opposite hemisphere Using these measurements it is possible
41. s tem perature must be controlled by a cooling system The module was powered on and its front end readout chips were exercised by providing a clock commands and triggers Figure 2 shows a diagram to illustrate the burn in setup It was composed of a vacuum system cooling sys tem interlocks DAQ system low voltage supplies high voltage supply and two PCs to control monitor and perform data analysis The photo in Figure 3 shows the laboratory where the modules arrived and the burn in took place from a number of angles The pictures shows the whole setup from the left and from the right side On the left side the visual inspection microscope the data analysis PCs and the DAQ hardware are shown On the right side the cooling system the vacuum system and reception area are shown 3 Reception and Visual Inspection The VELO modules on arrival from Liverpool university underwent the module reception pro cedure A check list was followed to verify if any visible problem could have happened dur ing the transportation This reception procedure included a check on the clamps feet captive screws paddle cooling face hybrid bond wires chips and silicon The integrity of the mod ule s kapton cables and respective clamps were also verified These components are shown in Figure 1 A high resolution visual inspection was done with a Lynx microscope equipped with cam era Photos were taken for further analysis For the inspection a module is mount
42. s used In order to optimise the GUI development Qt was taken as the main tool It is a cross platform application development framework provided by Trolltech It includes a library with a rich set of classes and functionality for GUI programming Manuals tutorials how to lists mailing lists and brownsable documentation are available A GUI layout designer is also avail able Qt designer ROOT was the straight forward choice to display data and save it into a recognisable format This set of tools and classes have been proven to be easy to use and robust enough for the burn in lab needs To integrate both Qt and ROOT the so called QtROOT 14 interface developed and maintained by GSI was used Nowadays this package is available in ROOT versions above 5 11 02 A simple software architecture was chosen in order to simplify the programming activities and maintenance Each of the devices mentioned had an application that runs independent of the others A basic set of four classes composes the applications a system class GUI class monitoring thread class and device class were implemented for each device The GUI class is the interface to the user It reads out the inputs and commands given by the user and displays the current status of the device The GUI has a pointer to the system class such that the instructions given by the user can be delivered to the hardware device The signal slots mechanism provided by Qt is used for this purpose When an acti
43. sted without a module using just a 10KQ NTC directly connected to the input The unit was triggered heating the NTC with a hot air gun and the unit relays opened their electrical contacts for the low voltage and high voltage as expected Pressure Interlock Unit The pressure interlock unit was composed of two BROICE 45050 unit relays 16 They could operate in two modes This model was able to operate in three different input voltage ranges In the burn in setup the latching mode was used in such a way that if they were triggered it would be necessary to manually turn them off and restart again The overvoltage hysteresis and time delay from a fault were adjustable The latching facility and relay inversion were selectable features Table 4 lists the possible values the parameters mentioned could assume The relays were triggered via the 5 V delivered by the Controller 201 device in case of a vacuum system failure Figure 13 illustrates the electrical connections of the unit On the front panel of the pressure interlock unit values for the hysteresis could be set A set of two 230 V plugs male and female and two banana plugs were available at the back to connect the Iseg safety loop and the Agilent power cable One BROICE unit was used to interlock the low voltage supply and the other was used to interlock the High voltage safety loop The mains power cable connection for the unit was also located at the back panel The pressure interlock was verifi
44. t This second version should 27 be tested and employed for the future use of the burn in system Acknowledgements The authors would like to thank all the VELO group for the valuable input on the burn in comissioning special thanks to Doris Eckstein Jan Buytaert Kazuyoshi Akiba Lars Eklund Paula Collins Peter Cooke Richard Jacobsson Themis Bowcock and Tony Smith References 1 VELO module characterisation Results from the glasgow LHCb VELO module burn in LHCb 2007 103 2 Reoptimized LHCb Detector Design and Performance TDR CERN LHCC 2003 030 3 LHCb Technical Design Report Vertex Locator CERN LHCC 2001 011 4 LHCb Liverpool Home http hep ph liv ac uk Ihcb index html November 2006 5 The Beetle Manual Reference LHCb 2005 105 6 Test Method for Standard Microcircuitry MIL STD 883F 7 General Environmental Specification for STS ELV payloads Subsystems and Compo nents GEVS SE Rev A 8 VELO module transport box document and operational guide Syracuse University note SU LHCb 2006 02 03 9 Vacuum studies with a VELO module LHCb 2007 104 10 Huber Peter Huber Kaultemaschinenbau GmbH Werner von Siemens Strasse 1 D 77656 Offenburg Germany Operating instructions for units with CC1 CC2 CC3 1 0 05 edition 11 Huber webpage http www huber online com October 2005 12 Qt Trolltech http www trolltech com products qt October 2005 13 ROOT An Object Ori
45. t and the Keithley multimeter were controlled by the software suite described in Section 4 4 14 har r Figure 10 The cooling block has a two piece design connected by an U of cooper that enables deformation without buckling It can bend inwards and outwards in the plane of the cooling block to take into account the expansion and contraction of the whole cooling block The cooling block was attached to the module during the mounting procedure The module was placed in a special frame which had a hood to protect the silicon during the mounting The cooling block was attached to the frame and a support at the opposite side was used to optimise the cooling connection and position the cooling block correctly 15 Table 3 List of devices drivers and protocols in the monitoring software Device Protocol Chiller Huber RS232 Keithley GPIB Acilent GPIB Iseg USB 4 4 Monitoring and Control Software System To monitor and control the components of the system during the burn in tests software algo rithms were developed There was a separate graphical user interface application GUI for each device running independently of the others To display the data read out from different devices a data display program was made All the code was written using C coding and a single set of technologies based on Qt 12 and ROOT 13 Table 3 lists the devices controlled by software their function on the burn in driver names and communication protocol
46. to the cooling block The curved shape of the hoses was designed such that the cooling block was not pushed against the module In fact it tends to bring the cooling block to the lid direction The cooling block was the part of the cooling circuit that was attached to the module cool ing face to provide the actual removal of the heat from the module to the coolant liquid that 12 Figure 9 The flexible hoses were connected on the feedthroughs and cooling block The length of the tubes has been chosen such that low stress was applied to the cooling block The curved shape of the hoses was such that the cooling block was not pushed against the module circulates inside it Its mechanical design satisfies the following set of requirements e The thermal interface between the cooling block and the module should be such that no mechanical stress is applied to the module e The cooling block shape must maximise the contact area with the module cooling face e The cooling block should fit in the 5 mm gap between the module cooling face and the kapton cables If the displacement of the paddle or hybrid with respect to its original position is of the order of 100 um it could cause a permanent deformation and therefore a systematic misalignment of the module It could also damage the hybrid and or the sensors The second item directly affects the performance of the cooling system to remove heat from the module The size of the contact surface o