Home

User Manual - Transition Networks

image

Contents

1. m Verify that you are using the right power cord adapter Using a power adapter output higher than the rated power input may damage the switch m Select the proper UTP STP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Q Category 3 4 or 5 cable for 10Mbps connections or 1000 Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet m Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through the front panel LED indicators which describe common problems the user may encounter and where the user can find possible solutions m IF the power indicator does not light on when the power cord is plugged in you may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet If you still cannot resolve the problem contact your local dealer for assistance m If the LED indicators are normal with the correctly connected cables and the packets still cannot transmit please check your system s Ethernet devices configuration or status 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600
2. This assures that data is properly transmitted Dual Power Input To reduce the risk of power failure the Industrial switch provides 12 48 Vpc dual power inputs If there is power failure the Industrial switch will automatically switch to the secondary power input Flexible Mounting The industrial switch is extremely compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Advanced Protection The power inputs provide up to 3 000 Vpc EFT protection which secures the equipment against unregulated voltage and makes the system safer and more reliable The RJ 45 Ethernet ports include 6 000 Vpc ESD protection 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Extended Operating Temperature The operating temperature of the Industrial switch is between 40 65 C extended operating temperature model or 10 50 C standard model With such a wide range you can use the Industrial switch in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and Fault help you diagnose immediately 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0
3. 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below Insert the wires to an external alarm system or indictor Fault status will be signaled by the alarm contacts if the power fails or there is a port link failure for managed model and form an open circuit Note The wire gauge for the terminal block should be in the range between 12 24 AWG 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch at the factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw on the DIN Rail on the industrial switch 2 Toremove the DIN Rail reverse the step 1 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T 3 First insert the top of DIN Rail into the track 4 Then lightly push the button of DIN Rail into the track 5 Check the DIN Rail is tightly on the track 6 Toremove the industrial switch from the track reverse steps above 24 Hour Technical Support 1 80
4. 10 100TX 2 93 Watts max 8 port 10 100TX 4 71 Watts max 2 x Unregulated 12 48 Vpc 1 Relay Output 30 x 95 x 140 International 00 1 952 941 7600 Transition Networks Enclosure Mounting Protection ESD Ethernet Surge EFT for power Power Reverse Environment Standard Operating Temperature Extend Operating Temperature LRT models only Operating Humidity Storage Temperature Certifications Safety EMC 24 Hour Technical Support 1 800 260 1312 SISTF1010 2X0 LR T IP 30 Metal shell with solid mounting kits DIN35 rail Wall 6 000 Vpc 3 000 Voc Yes 100 500 32 F 140 F 40 75 C 40 F 167 F 5 95 non condensing 40 85 C 40 F 185 F UL cUL CE EN60950 1 Class 1 Division 2 FCC Class A CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE EN61000 4 8 ESD RS EFT Surge CS Magnetic Field i ge pew pes Gr International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T CE EN61000 4 11 Voltage DIP CE EN61000 6 2 CE EN61000 6 4 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Packing List m 1x5 port 10 100TX Industrial Ethernet Switch or 1x 8 port 10 100TX Industrial Ethernet Switch m 1x User Manual m 2x Wall Mounting Bracket and Screws Compare the contents of the industrial switch with the standard checklist above If any
5. Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive Fault Red on Power input 1 and 2 are both functional or no power inputs On Connected to network Link Active Green Flashing Networking is active 1 5 or 1 8 Off Not connected to network On Ethernet port full duplex Duplex Collision 1 5 or 1 8 Orange Flashing Collision of packets occurs Off Ethernet port half duplex or not connect to network 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks Ports SISTF1010 2X0 LR T RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T or 100Base TX device connections Auto MDI MDIX means that you can connect to another switch or workstation without changing to straight through or crossover cabling See figures below for straight through and crossover cable schematic m RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of
6. LR T Features Provides 5 x 10 100 Mbps 5 port 10 100TX model or 8 x 10 100 Mbps 8 port 10 100TX model Ethernet ports m Supports full half duplex flow control m Supports MDI MDI X auto crossover m Supports surge EFT protection 3 000 Vpc for power line m Supports 6 000 Vpc Ethernet ESD protection m Provides broadcast storm protection m Embedded with a switch controller supports auto negotiation m Embedded with memory buffer supports store amp forward transmission m Supports redundant 12 48 Vpc power input m Provides flexible mounting DIN rail Panel Mounting m Supports Extended operating temperatures from 40 65 C LRT model or 10 50 C LR model 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Technical Specification The technical specifications of the Industrial Switch are listed as follows Communications Compatibility LAN Transmission Distance Transmission Speed Broadcast Storm Rate Limit Interface Connectors LED Indicators Power Power Consumption Power Input Fault Output Mechanism Dimensions WxHxD 24 Hour Technical Support 1 800 260 1312 IEEE 802 3 802 3u 10 100Base TX Up to 100 m Up to 100 Mbps 200pps 100M 20pps 10M 5 x RJ 45 5 port 10 100TX 8 x RJ 45 8 port 10 100TX 6 pin removable screw terminal power Unit P1 P2 Fault TX port Link Active Full Duplex Collision 5 port
7. item is damaged or missing please contact the local dealer for service Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Hardware Description The following will introduce the Industrial switch s hardware spec port cabling information and wiring installation Front Panel The Front Panel of the 5 port and 8 port 10 100BaseTX Industrial Switch is shown as below LED Indicator RJ 45 Port Front Panel of the 5 port amp 8 port 10 100BaseTX Industrial Switch 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Top View The top panel of the 5 port amp 8 port 10 100BaseTX Industrial Switch is equipped with a terminal block connector for connecting input power and providing the fault output contacts Top Panel of the 5 port amp 8 port 10 100BaseTX Industrial Switch 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T LED Indicators There are a few LEDs to display the input power and network status located on the front panel of the Industrial switch each of them has its own specific meaning as illustrated in the table below LED
8. 0 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loosen the screws to remove the DIN Rail 2 Place the wall mount plate on the top amp bottom side of the industrial switch Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse steps above w 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Hardware Installation Below we will describe how to install the 5 port or 8 port 10 100Base TX Industrial Switch in the application I Add SE dd Data collect server Human Management Interface Enterprise Switch Industrial Industrial Industrial Switch Switch Switch po a Field Management Programmable logic controller Distribute 1 0 control system F Device Server t Field Automatic device Field Automatic device Field Automatic device Installation Steps 1 Unpack the Industrial switch packing 2 Check the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail 24 Hour Technica
9. 5 port amp 8 port 10 100BaseTX Industrial Switch User Manual SISTF1010 250 LR T amp SISTF1010 280 LR T aa eee V1 10 Jun 2009 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna M Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected m Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content FOC Warning ENE EE i G
10. EGEN i OVE ON E MN FAN PN Technical Specification ssiccviss arasrectorasarssevswavisevivgsans PACKING REE inane Safety Precauion u mirmminununeismisomntnssknue Hardware Description ccccccccccseessssssssseeeeeees 2 PNL TN LED NIE eee Go EE NN NE Wiring the Power Inputs eererrronrnnnnnnnnnnnnnnnnnnennn Wiring the Fault Alarm Contact rrnnnnnnnnnrnnnnnnnn Mounting Installation Larvene nmnda Transition Networks SISTF1010 2X0 LR T PIN FA MON kanne d eteen 9 Wall Mount Plate Mounting eeerrrnrrnnnnnnnnnnnnnnnnr 11 Hardware Installation cccccccecccceeeeeeeeeeeeeeees 12 Installation Steps esrrnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnennne 12 Troublesnoonmngu uusrmnmsnsmennnisnssennnv 14 Transition Networks SISTF1010 2X0 LR T Overview Introduction This user manual is suitable for the products as follows e 5 port 10 100TX Unmanaged Industrial Switch e 8 port 10 100TX Unmanaged Industrial Switch The unmanaged industrial switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications High Speed Transmissions The Industrial switch includes a switch controller that can automatically sense transmission speeds 10 100 Mbps The RJ 45 interface can auto detect so MDI or MDI X is automatically selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanism
11. l Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T installation If you want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch For instructions on how to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of Category 5 cables into the Industrial switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch PC or server The UTP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light meaning Note Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 cable 7 When all connections are all set and LED lights all show in normal the installation is complete 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Troubleshooting
12. the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Switch Router or PC 3 TD s gt 3 RD 6 TD gt 6 RD 1 RD lt TD 2 RD 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic Cabling Use the four twisted pair Category 5 cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SISTF1010 2X0 LR T Wiring the Power Inputs Please follow the steps below to insert the power wire V V V V 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 Tighten the wire clamp screws to secure the wires 24 Hour Technical Support

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation  eLib: System Requirements Specification  取扱説明書 - サウンドハウス  switch - Brondi  View/Open  TeleWell TW-EA501 v2 ADSL2+ Router 4 x 10/100Mbps switch  hand dyer - Control Zone Products  Sistema JKA211    取扱説明書 - Honda  

Copyright © All rights reserved.
Failed to retrieve file