1. c ROOM TEMPERATURE is defective open short circuited varies more than 20 0 F in a one minute period ATTACHMENTS e Parameter Table e Labels e Wiring Diagram 6M70F0 Page 11 of 16 08 25 2006 PARAMETER TABLE E RYE Ei mer I ROOM TEMPERATURE ge oes mm F3 Hi Lo so 1e M 2 DESIRED ROOM TEMP h e n J F2 Adjust Day mois de E 397 7 TREES F3 Adjust Temperature F 120 0 780 750 70 0 65 0 3 INSIDE TEMP 1 e so is E F2 Probe Input Z F3 Hi Lo dg F CLR 60 1086 ww 4 INSIDE TEMP 2 so 1686 mem F3 Hi Lo deg F CLR 60 1686 er 5 INSIDE TEMP 3 a UNE a F3 Hi Lo sfar so 16 M 6 INSIDE TEMP 4 is v F2 Probe Input F3 Hi Lo 7 HEATER RSP F2 Heater Diff 8 FAN 1 RSP pm 00 F2 Fan 1 Min Speed none 12 100 so F3 Fan 1 Mod Band deg F none 0s 309 20 _ 9 FAN 2 RSP deg F none 10 0 300 20 F2 Fan 2 Min Speed none 11 10 so F3 Fan 2 Mod Band deg F prone 8189 1 L 10 MIN VENT TIMER DUTY CYCLE F2 Min Vent Timer Period min F3 Fan 2 On Timer I yes FEST CN DU a rT See 1309 40 I F2 Fan 3 Diff deg Flnone 05 50 10 anars 891390 1 89 F2 Fan 4 Diff ee 1 13 INLET PO
2. EXERCISE CLOSE This parameter is used to activate the curtain exercise feature that is used to remove the conditions water rodents etc that can cause premature curtain failure If this parameter is set to ON the curtain will close for CURTAIN EXERCISE DURATION every time the CURTAIN EXERCISE DAY COUNTER reaches the CURTAIN EXERCISE FREQUENCY After the closing delay if the ROOM TEMPERATURE is above DRT CURTAIN RSP CURTAIN DEAD BAND the curtain will open for CURTAIN EXERCISE DURATION Adjusting this parameter to 0 no will reset the day counter Ex See CURTAIN EXERCISE FREQUENCY CURTAIN EXERCISE FREQUENCY This parameter is used to adjust the frequency at which the curtain exercise function will activate When the CURTAIN EXERCISE DAY COUNTER reaches this parameter the curtains will close for CURTAIN EXERCISE DURATION If the temperature is still above DRT CURTAIN OPEN RSP CURTAIN DEAD BAND the curtain will open for CURTAIN EXERCISE DURATION This parameter is adjusted in 1 day increments from 1 to 100 days Ex CURTAIN EXERCISE FREQUENCY 60 days CURTAIN EXERCISE DURATION 3 minutes If the control is powered or the CURTAIN EXERCISE CLOSE is set to ON at 6 26pm every 60 days at 6 26pm the curtain will close for 3 minutes After the closing delay if the ROOM TEMPERATURE is above DRT CURTAIN RSP CURTAIN DEAD BAND the curtain will open for 3 minutes CURTAIN EXERCISE DURATION This parameter is used to adjust the amount of time
3. will be activated Each INSIDE TEMPERATURE is displayed to the nearest 0 1 F from 6 0 F to 168 6 F See note 1 Notel In addition to the readout of the probe the probe parameters can record the lowest and highest values reached To access the Hi Lo recorded values press F3 at the respective probe parameter To clear the respective Hi Lo values after pressing F3 press and hold the and buttons until CLR appears on the LED display Parameters 7 F2 HEATER RSP This parameter is used to establish the temperature RSP at which the heater begins to operate HEATER RSP is adjusted in 0 5 F increments from 10 0 F to 5 0 F HEATER DIFF This parameter is used to establish the differential of the heater output The HEATER DIFF is adjusted in 0 5 F increments from 0 5 F to 5 0 F Parameter 8 FAN 1 RSP This parameter is used to establish the temperature RSP at which fan 1 begins to modulate When ROOM TEMPERATURE reaches FAN 1 RSP fan 1 will start to modulate from FAN 1 MIN SPEED at FAN 1 RSP to finish at 100 when temperature is at the end of FAN 1 MOD BAND When the ROOM TEMPERATURE is below FAN 1 RSP fan 1 will run according to the minimum ventilation timer at FAN J MIN SPEED This parameter is adjusted in 0 5 F increments from 10 0 F to 30 0 F 6M70F0 Page 3 of 16 08 25 2006 F2 F3 FAN 1 MIN SPEED This parameter is used to establish the minimum speed of fan 1 When the ROOM TEMPERATURE is below the
4. CONTROL LOGIC DESCRIPTION DOCUMENT Configuration 6M70F0 Input Output Table Outputs Inside Temperature Variable Speed Stage Single Speed Stage Inlet Curtain Heater Cooling Stage Alarm Equipment Required Description Intelligent Control 6 inputs 10 outputs Curtain Inlet Position Variable Power Module 2 Outputs 10 Amperes Temperature Probe Red 6 0 F to 168 6 F Configuration Versions 08 16 2006 6M70F0 Page 1 of 16 08 25 2006 1 GENERAL The IC 610 is a powerful control which can be programmed to work in many types of buildings just by changing the configuration logic The configuration logic is the software that makes the relation between the sensor readings the parameters and the outputs This software is stored in a chip identified with the configuration number as shown in the title of this document and as it appears on your left hand side label of your control Please always provide this configuration number when you discuss with your provider To install properly and fully understand your IC 610 it is important to read both the IC 610 user s manual and this Control Logic Document The user s manual informs you on safety issues warranty sensors how to change parameters and many others characteristics of the IC 610 whereas this document explains all particularities of this configuration logic Section 2 explains what the user can control with adjustable
5. FAN RSP fan 1 will run according to the minimum ventilation timer at minimum speed The FAN MIN SPEED is adjusted in 1 increments from 12 to 100 FAN 1 MOD BAND This parameter is used to establish the range of temperature where fan 1 speeds up as ROOM TEMPERATURE increases Fan 1 increases its speed from its minimum speed FAN 1 MIN SPEED at FAN 1 RSP to its maximum speed at the end of the FAN 1 MOD BAND The FAN 1 MOD BAND is adjusted in 0 5 F increments from 0 5 F to 10 0 F Parameter 9 F2 F3 FAN 2 RSP This parameter is used to establish the temperature RSP at which fan 2 begins to modulate When ROOM TEMPERATURE reaches FAN 2 RSP fan 2 will start to modulate from FAN 2 MIN SPEED at FAN 2 RSP to finish at 100 when temperature is at the end of FAN 2 MOD BAND When ROOM TEMPERATURE is below FAN 2 RSP fan 2 will run according to the minimum ventilation timer at FAN 2 MIN SPEED if the FAN 2 ON TIMER option is set to ON The FAN 2 RSP is adjusted in 0 5 F increments from 10 0 F to 30 0 F FAN 2 MIN SPEED This parameter is used to establish the minimum speed of fan 2 When ROOM TEMPERATURE is below the FAN 2 RSP fan 2 will run according to the minimum ventilation timer at minimum speed if FAN 2 ON TIMER is set to ON The FAN 2 MIN SPEED is adjusted in 1 increments from 12 to 100 FAN 2 MOD BAND This parameter is used to establish the range of temperature where fan 2 speeds up as ROOM TEMPERATURE increases Fan 2 in
6. LENGTH whichever is shorter COMMUNICATION WIRING SHIELDED LOW CAPACITANCE WIRE Capacitance between conductors 1Khz 24PF FT TWISTED PAIR 8 twist FT AWG 18 TO 22 750 FT 250 M MAX LENGTH Ex BELDEN 8761 HIGH VOLTAGE WIRE INSTALLED ACCORDING TO LOCAL WIRING CODE INSTALL LOW VOLTAGE WIRES PROBES COMPUTER LINK OR POTENTIOMETER WIRES AT LEAST 12 INCHES 30cm AWAY FROM HIGH VOLTAGE WIRES 120 230VAC 24VDC ALWAYS CROSS HIGH AND LOW VOLTAGE WIRES ATA 90 DEGREE ANGLE RELAYS 10A 250VAC RESISTIVE MOTOR 1HP 250VAC 1 2HP 120VAC AT EACH OUTPUT OUT 1 6 MAXIMUM 2 WIRES OF SAME SIZE PER BLACK TERMINAL NO BIGGER THAN AWG 12 NO SMALLER THAN AWG 22 1 WIRE ONLY PER GREEN TERMINAL USE WIRE CONNECTOR IF YOU WANT TO CONNECT MORE THAN 1 WIRE CHECK INSTALLATION GUIDE FOR ALARM WIRING USE SHIELD FOR SHIELDING PURPOSE ONLY CONNECT THE SHIELD TO THE CONTROL CIRCUIT COMMON END ONLY NEVER LEAVE THE SHIELD UNCONNECTED AT BOTH ENDS NEVER CONNECT BOTH ENDS OF THE SHIELD TO COMMON THE USE OF A SHIELD FOR ALL PROBES AND POTENTIOMETERS IS MANDATORY THESE MODULES MUST BE ON SAME POWER PHASE AND LINE VOLTAGE AS THE CONTROLLER Page 16 of 16 08 25 2006
7. SITION FANI MIN mm o 100 1 T F2 Inlet Position Fan 1 Max none 9 1 0 20 14 INLET POSITION FAN2MIN none 0 10 30 F2 Inlet Position Fan 2 Max none 09 1 70 4 15 INLET POSITION FAN 3 none 9 10 o F2 Inlet Position Fan 4 prone 2 f o j ff 16 COOLING RSP deg F nof 200 f o0 f iso L F2 Cooling Diff deg F none 6M70F0 Page 12 of 16 08 25 2006 DESCRIPTION ee S M CONTROL VALUES PRESET 17 COOLING DUTY CYCLE 10 F2 Cooling Period min 20 18 CURTAIN OPEN RSP deg F 7 0 F2 Run Time Open sec 20 F2 Run Time Close sec 40 F2 Curtain Delay Between Move min 3 F2 First Natural Move sec 30 F2 Curtain Dead Band deg F 3 i F2 of Cycle to Stop Fans 19 ACCELERATED OPEN 0 no F2 Seconds Increase sec 20 CURTAIN EXERCISE CLOSE 0 no F2 Curtain Exercise Frequency day F3 Curtain Exercise Duration min 21 CURT EXE DAY COUNTER day 22 FAN 1 OPERATION IN NATURAL on off F2 Fan 2 Operation in Natural on off F2 Fan 3 Operation in Natural on off F2 Fan 4 Operation in Natural on off 23 ALARM HI TEMP RSP deg F F2 Alarm Lo Temp RSP deg F OUT DN RU RN ERA 24 MANUAL OVERRIDE FAN 1 mone autoo 10 aum F2 Manual Override Fan 2 F2 Manual Override Fan 3 F2 Manual Override Fan 4 25 MANUAL OVERRIDE HEATER F2 Manual Override Cooling F3 Manual Override Curtain 0 Stop 1 Close 26 GROWTH DAY d
8. ay F2 Adjust day day AUTO 0 1 OPEN AUTO 1 Ee rop om poppe E T Restriction legend Parameter adjustable by the user and the supervisor Invisible to the user when supervisor mode is OFF Read only to the user when supervisor mode is OFF Follow a growth curve when ramping function is ON Cannot be changed Press simultaneously to clear 6M70F0 Page 13 of 16 08 25 2006 6M70FO 1 Room Temperature 2 Desired Room Temp DRT 3 6 Inside Probe 1 4 7 Heater Settings 8 Fan 1 Settings 9 Fan 2 Settings 10 Min Vent Settings 11 Fan 3 Settings 12 Fan 4 Settings 13 15 Inlet Position Settings 16 17 Cooling Settings 18 Curtain Settings 19 Accelerated Open 20 Curtain Exercise Settings 21 Curt Exercise Day Counter 22 Fan Operation in Nat 23 Alarm Settings 24 25 Manual Override 26 Growth Day 6M70FO 1 Room Temperature 2 Desired Room Temp DRT 3 6 Inside Probe 1 4 7 Heater Settings 8 Fan 1 Settings 9 Fan 2 Settings 10 Min Vent Settings 11 Fan 3 Settings 12 Fan 4 Settings 13 15 Inlet Position Settings 16 17 Cooling Settings 18 Curtain Settings 19 Accelerated Open 20 Curtain Exercise Settings 21 Day Counter 22 Fan Operation in Nat 23 Alarm Settings 24 25 Manual Override 26 Growth Day 1 Curtain Open 1 Curtain Open 2 Curtain C
9. ccur The ALARM HI TEMP RSP is adjusted in 0 1 F increments from 0 0 F to 40 0 F See also the alarm section 3 for other alarm conditions ALARM LO TEMP RSP This parameter is used to establish the temperature RSP at which a low temperature alarm condition will occur When the ROOM TEMPERATURE is lesser than DRT ALARM LO TEMP RSP an alarm will occur The ALARM LO TEMP RSP is adjusted in 0 1 F increments from 20 0 F to 1 0 F See also the alarm section 3 for other alarm conditions Parameter 24 F2 F2 F2 MANUAL OVERRIDE FAN 1 MANUAL OVERRIDE FAN 2 These parameters are used to control manually the respective fan 1 2 When this parameter is set to AUTO the respective fan 1 2 will follow the configuration logic When this parameter is set to 0 the respective fan 1 2 will be deactivated When this parameter is set to a value between 1 and 100 the respective fan 1 2 will run at the corresponding speed MANUAL OVERRIDE FAN 3 MANUAL OVERRIDE FAN 4 These parameters are used to control manually the respective fan 3 4 When this parameter is set to AUTO the respective fan 3 4 will follow the configuration logic When this parameter is set to 0 the respective fan 3 4 will be deactivated When this parameter is set to ON the respective 3 4 will be activated Parameter 25 F2 F3 MANUAL OVERRIDE HEATER These parameters are used to control manually the heater When this parameter is set to AUTO the heater
10. closing according to the curtain timer The CURTAIN DELAY BETWEEN MOVE is adjusted in 1 minute increments from 1 minute to 10 minutes Ex See CURTAIN DEAD BAND for example FIRST NATURAL MOVE This parameter is used to establish the time for which a curtain will open on the first opening cycle When temperature has fallen below DRT CURTAIN OPEN RSP the next opening cycle will use FIRST NATURAL MOVE instead of RUN TIME OPEN The FIRST NATURAL MOVE is adjusted in 1 second increments from 5 to 120 seconds Ex See CURTAIN DEAD BAND for example CURTAIN DEAD BAND This parameter is used to establish the temperature range within which the curtain will not move When temperature is below DRT CURTAIN OPEN RSP CURTAIN DEAD BAND and above DRT CURTAIN OPEN RSP the curtain will stay put Above this range curtain will open and below this range curtain will close This parameter is adjusted in 0 1 F increments from 0 5 F to 2 0 F Ex DRT 70 F CURTAIN OPEN RSP 7 0 F CURTAIN DEAD BAND 2 0 F CURTAIN DELAY BETWEEN MOVE 5 min FIRST NATURAL MOVE 120 sec RUN TIME OPEN 60 sec RUN TIME CLOSE 120 sec HEATER RSP 4 0 F When the ROOM TEMPERATURE increases the curtain will react as follows until 67 0 F closes continuously between 67 0 F and 77 3 F closes on a timer close for 120 seconds and stay put for 5 minutes between 77 4 F and 78 9 F does not move this is the dead band at 79 0 F and up opens on a timer open
11. creases its speed from its minimum speed FAN 2 MIN SPEED at FAN 2 RSP to its maximum speed at the end of the FAN 2 MOD BAND The FAN 2 MOD BAND is adjusted in 0 5 F increments from 0 5 F to 10 0 F Parameter 10 F2 MIN VENT TIMER DUTY CYCLE This parameter is used to establish the cycle of a period of time for the minimum ventilation timer When ROOM TEMPERATURE is below the FAN 1 2 RSP that fan will be activated during a cycle of time MIN VENT TIMER DUTY CYCLE of a period MIN VENT TIMER PERIOD The MIN VENT TIMER DUTY CYCLE is adjusted in 1 increments from 0 to 100 Ex See MIN VENT TIMER PERIOD for example MIN VENT TIMER PERIOD This parameter is used to establish the period for the minimum ventilation timer When ROOM TEMPERATURE is below the FAN 1 2 RSP that fan will be activated during a cycle of time MIN VENT TIMER DUTY CYCLE of a period MIN VENT TIMER PERIOD The MIN VENT TIMER PERIOD is adjusted in 1 minute increments from 1 minute to 20 minutes Ex DRT 70 0 F FAN RSP 2 0 F MIN VENT TIMER DUTY CYCLE 50 MIN VENT TIMER PERIOD 2 minutes When inside temperature is below 72 0 F Fan will cycle ON 1 minute at minimum speed and OFF 1 minute 6M70F0 Page 4 of 16 08 25 2006 F3 FAN 2 ON TIMER This parameter is used to determine if fan 2 will work off the minimum ventilation timer If this option is set to 1 YES fan 2 will cycle on minimum ventilation timer when ROOM TEMPERATURE is below its RSP If t
12. eter 18 F2 CURTAIN OPEN RSP This temperature is used to adjust the temperature at which the curtain will stop closing and the control exits natural mode When the ROOM TEMPERATURE reaches DRT CURTAIN OPEN RSP 0 3 F the curtain will stop closing The control exits natural mode when the ROOM TEMPERATURE drops to DRT CURTAIN OPEN RSP This parameter is adjusted in 0 1 F increments from 5 0 F to 20 0 F RUN TIME OPEN This parameter is used to establish the duration of the run time when the curtain opens When temperature rises to DRT CURTAIN OPEN RSP CURTAIN DEAD BAND the curtain will open during RUN TIME OPEN and will keep its position for CURTAIN DELAY BETWEEN MOVE The RUN TIME OPEN is adjusted in 1 second increments from 5 to 300 seconds Ex See CURTAIN DEAD BAND for example 6M70F0 Page 6 of 16 08 25 2006 F2 F2 F2 F2 F2 RUN TIME CLOSE This parameter is used to establish the duration of the run time when the curtain closes When temperature drops to DRT CURTAIN OPEN RSP the curtain will close during RUN TIME CLOSE and keep its position for CURTAIN DELAY BETWEEN MOVE However if ROOM TEMPERATURE drops below DRT HEATER RSP the curtain will close continuously The RUN TIME CLOSE is adjusted in 1 second increments from 5 to 300 seconds Ex See CURTAIN DEAD BAND for example CURTAIN DELAY BETWEEN MOVE This parameter is used to establish the time for which the curtain will not move when it is opening or
13. for 120 seconds and stay put for 5 minutes on the first cycle then open for 60 seconds and stay put for 5 minutes for all other cycles When the ROOM TEMPERATURE decreases the curtain will react as follows until 78 7 F opens on a timer open for 60 seconds and stay put for 5 minutes between 78 7 F and 77 0 F does not move this is the dead band between 76 9 F and 67 0 F closes on a timer close for 120 seconds and stay put for 5 minutes at and below 67 0 F closes continuously OF CYCLES TO STOP FANS This parameter is used to adjust the number of open cycles RUN TIME OPEN CURTAIN DELAY BETWEEN MOVE it takes before the control enters natural mode and the fans shut down OF CYCLES TO STOP FANS is adjusted in 1 cycle increments from 1 to 6 cycles 6M70F0 Page 7 of 16 08 25 2006 Parameter 19 F2 ACCELERATED OPEN This parameter is used to activate the accelerated open feature when the ROOM TEMPERATURE is above DRT CURTAIN OPEN RSP CURTAIN DEAD BAND 5 0 F If this parameter is adjusted to I yes the RUN TIME OPEN will be increased by SECONDS INCREASE The ACCELERATED OPEN can be adjusted to 1 yes or 0 no SECONDS INCREASE This parameter is used to adjust the amount of time that will be added to RUN TIME OPEN when the ROOM TEMPERATURE is above DRT CURTAIN OPEN RSP CURTAIN DEAD BAND 5 0 F This parameter is adjusted in 1 second increments from 0 to 30 seconds Parameter 20 F2 F3 CURTAIN
14. g layout and the wiring schematics in attachment for a typical installation 6M70F0 Page 2 of 16 08 25 2006 2 PARAMETER DESCRIPTION Parameter 1 F3 ROOM TEMPERATURE This parameter displays the average of the four temperature probes All outputs will follow this temperature The ROOM TEMPERATURE is displayed to the nearest 0 1 F from 6 0 F to 168 6 F See note 1 Parameter 2 F2 F3 DESIRED ROOM TEMPERATURE DRT This parameter is used to establish the target room temperature The DRT is used as the reference point for other relative settings When the GROWTH DAY is activated the control takes charge of this parameter so to have access to this parameter GROWTH DAY must be set to OFF The DRT is adjusted in 0 1 F increments from 32 0 F to 120 0 F ADJUST DAY 4 points This parameter is used to establish the days on the growth curve function The ADJUST DAY is adjusted in 1 day increments from day 1 to day 127 For more details see User s Manual ADJUST TEMP 4 points This parameter associates a temperature value for each day defined on the growth day function The ADJUST TEMP is adjusted in 0 1 F increments from 32 0 F to 120 0 F For more details see User s Manual Parameters 3 6 F3 INSIDE TEMPERATURE 1 4 These parameters display the temperature of the respective temperature probe The logic also checks this parameter to determine 1f a temperature is too high or too low at which point the alarm
15. his option is set to 0 NO fan 2 will be inactive when ROOM TEMPERATURE is below its RSP Parameter 11 F2 FAN 3 RSP This parameter is used to establish the RSP at which fan 3 begins to operate When ROOM TEMPERATURE reaches DRT FAN 3 RSP fan 3 will be activated The FAN 3 RSP is adjusted in 0 5 F increments from 10 0 F to 30 0 F FAN 3 DIFF This parameter is used to establish the differential for fan 3 When the ROOM TEMPERATURE reaches DRT FAN 3 RSP FAN 3 DIFF fan 3 will be deactivated The FAN 3 DIFF is adjusted in 0 5 F increments from 0 5 F to 5 0 F Parameter 12 F2 FAN 4 RSP This parameter is used to establish the RSP at which fan 4 begins to operate When ROOM TEMPERATURE reaches DRT FAN 4 RSP fan 4 will be activated The FAN 4 RSP is adjusted in 0 5 F increments from 10 0 F to 30 0 F FAN 4 DIFF This parameter is used to establish the differential for fan 4 When the ROOM TEMPERATURE reaches DRT FAN 4 RSP FAN 4 DIFF fan 4 will be deactivated The FAN 4 DIFF is adjusted in 0 5 F increments from 0 5 F to 5 0 F Parameter 13 F2 The inlet will close continously 1 minute after the curtain opens INLET POSITION FAN 1 MIN This parameter is used to establish the position of the inlet when only fan 1 is running at its minimum speed The NLET POSITION FAN 1 MIN 1s adjusted in 1 increments from 0 to 100 INLET POSITION FAN 1 MAX This parameter is used to establish the position of the inlet
16. lose 2 Curtain Close 3 Fan 3 Fan 4 Fan2 4 Fan2 5 Fan3 5 Fan3 6 Fan4 6 Fan4 7 Heater 7 Heater 8 Cooling 8 Cooling 7 9 Curtain Exercise 9 Curtain Exercise 10 Natural Mode 10 Natural Mode 6M70F0 Page 14 of 16 08 25 2006 WIRING DIAGRAM CONFIGURATION 6 7 INTELLIGENT COMPUTER 1 1 1 1 SEE NOTES ON NEXT PAGE 6M70F0 THESE MODULES MUST BE ON SAME PHASE AN AND LINE VOLTAGE THAN THE IC 610 2 VARIABEE SPEED CONTROLMODULE MHP G 115V MODULE 10A 120 240VAC LINE CURRENT VOLTAGE DETECTOR 5 L2 N L2 N L1 L1 Page 15 of 16 IC 610 1059E WARNING TO CORRECT VALUE BEFORE A A ATTEMPTING TO OPERATE THE COMPUTER SET LINE VOLTAGE LINE VOLTAGE SELECTOR REL1 2 REL3 REL4 RELS REL6 LINE NO C NO C NO C NO C NO C NO C NCL 1vexv L2 N i l L2 N L2 N L2 N L2 N L2 N L2 N L1 L1 L1 L1 L1 L1 COOLING CURTAIN OPEN CURTAIN CLOSE Varifan WIRING DIAGRAM E 04 08 06 Yanick Alain JDIAGIC GMTOF O 6M70FO 08 25 2006 PPP 0 E 6M70F0 6M70F0 Electrician s notes Wiring tips and hints see guide for details PROBE WIRING SHIELDED WIRE AWG 18 WITH 16 30 STRANDING 500FT 150M MAXIMUM LENGTH Ex DECA 73 310 For other probe refer to specific probe manual for appropriate maximum length and wire size or use AWG 18 500FT 150M MAXIMUM
17. parameters while the section 3 contains information for the alarm Definition Throughout this document the following terminology is used DRT Desired Room Temperature This is the temperature goal for the room and it is also the reference temperature for all relative settings Note that the DRT is affected by the growth curve function See the user s guide for more detail RSP9 Relative Set Point This 1s the number of degrees relative to the DRT where a function begins Differential Number of degrees changed before stopping the output For example with a differential 1 0 F the IC 610 turns on a fan at 70 0 F when temperature increases but it will shut it off only at 69 0 F when the room is cooling down The differential is necessary to avoid oscillations Modulation Band Number of degrees a variable speed fan takes to reach its full speed Expressions in TALICS are user s parameters Ventilation System Overview This configuration controls 2 variable speed stages both of which can work off a minimum ventilation timer when below their RSPs There are 2 On Off stages that run full time at maximum speed when above their respective RSP There is also an inlet that will open according to stage activation and a natural curtain that will be controlled according to the temperature A cooling output will be activated on a timer when above its RSP A heater output will be used when temperature is too low Refer to the buildin
18. perate When the ROOM TEMPERATURE reaches DRT COOLING RSP the cooling output will be activated according to its timer The COOLING RSP is adjusted in 0 5 F increments from 20 0 F to 30 0 F COOLING DIFF This parameter is used to establish the differential for the cooling output When the ROOM TEMPERATURE reaches DRT COOLING RSP COOLING DIFF the cooling output will be deactivated The COOLING DIFF is adjusted in 0 5 F increments from 0 5 F to 5 0 F Parameter 17 F2 COOLING DUTY CYCLE This parameter is used to establish the active cycle of a period of time for the cooling When ROOM TEMPERATURE is equal to or above the COOLING RSP cooling will be activated during a cycle of time COOLING DUTY CYCLE of a period COOLING PERIOD The COOLING DUTY CYCLE is adjusted in 1 increments from 0 to 100 Ex See COOLING PERIOD for example COOLING PERIOD This parameter is used to establish the duration of the cooling period When the ROOM TEMPERATURE is above or equal to the COOLING RSP cooling will be activated during a cycle of time COOLING DUTY CYCLE of a period COOLING PERIOD The COOLING PERIOD is adjusted in 1 minute increments from 1 minute to 20 minutes Ex DRT 70 0 F COOLING RSP 12 0 F COOLING DIFF 1 0 F COOLING DUTY CYCLE 10 COOLING PERIOD 10 minutes When ROOM TEMPERATURE reaches 82 0 F the cooling will cycle ON 1 minute and OFF 9 minutes Cooling will deactivate when temperature drops to 81 0 F Param
19. the curtain will open close when the curtain exercise occurs This parameter is adjusted in 1 minute increments from 1 to 5 minutes Parameter Z 21 CURTAIN EXERCISE DAY COUNTER This parameter displays how many days have passed since the last curtain exercise The curtain exercise is done every CURTAIN EXERCISE FREQUENCY This parameter is displayed to the nearest day from 1 to 100 days Parameter 22 F2 FAN 1 OPERATION IN NATURAL This parameter is used to activate or deactivate the fan 1 in natural mode If this parameter is set to ON the fan 1 will be allowed to function in natural mode FAN 2 OPERATION IN NATURAL This parameter is used to activate or deactivate the fan 2 in natural mode If this parameter is set to ON the fan 2 will be allowed to function in natural mode 6M70F0 Page 8 of 16 08 25 2006 F2 F2 FAN 3 OPERATION IN NATURAL This parameter is used to activate or deactivate the fan 3 in natural mode If this parameter is set to ON the fan 3 will be allowed to function in natural mode FAN 4 OPERATION IN NATURAL This parameter is used to activate or deactivate the fan 4 in natural mode If this parameter is set to ON the fan 4 will be allowed to function in natural mode Parameter 23 F2 ALARM HI TEMP RSP This parameter is used to establish the temperature RSP at which a high temperature alarm condition will occur When the ROOM TEMPERATURE is greater than DRT ALARM HI TEMP RSP an alarm will o
20. when fan 1 is running at its maximum speed ROOM TEMPERATURE is equal to or above FAN 1 RSP FAN 1 MOD BAND The INLET POSITION FAN 1 MAX is adjusted in 1 increments from 0 to 100 Parameter 14 F2 The inlet will close continously 1 minute after the curtain opens INLET POSITION FAN 2 MIN This parameter is used to establish the position of the inlet when only fan 2 is running at its minimum speed The NLET POSITION FAN 2 MIN is adjusted in 1 increments from 0 to 100 INLET POSITION FAN 2 MAX This parameter is used to establish the position of the inlet when fan 2 is running at its maximum speed ROOM TEMPERATURE is equal to or above FAN 2 RSP FAN 2 MOD BAND The INLET POSITION FAN 2 MAX is adjusted in 1 increments from 0 to 100 Parameter 15 The inlet will close continously 1 minute after the curtain opens INLET POSITION FAN 3 This parameter is used to establish the position of the inlet when fan 3 is activated ROOM TEMPERATURE is equal to or above FAN 3 RSP INLET POSITION FAN 3 is adjusted in 1 increments from 0 to 100 6M70F0 Page 5 of 16 08 25 2006 F2 INLET POSITION FAN 4 This parameter is used to establish the position of the inlet when fan 4 is activated ROOM TEMPERATURE is equal to or above FAN 4 RSP INLET POSITION FAN 4 is adjusted in 196 increments from 0 to 100 Parameter 16 F2 COOLING RSP This parameter is used to establish the temperature RSP at which the cooling begins to o
21. will follow the configuration logic When this parameter is set to 0 the heater will be deactivated When this parameter is set to ON the heater will be activated MANUAL OVERRIDE COOLING These parameters are used to control manually the cooling When this parameter is set to AUTO the cooling will follow the configuration logic When this parameter 1s set to 0 the cooling will be deactivated When this parameter is set to ON the cooling will be activated MANUAL OVERRIDE CURTAIN These parameters are used to control manually the curtain When this parameter is set to AUTO the curtain will follow the configuration logic When this parameter is set to 0 the curtain will stp moving If the parameter is set to 1 the curtain will close and when this parameter is set to open the curtain will be open Parameter 26 GROWTH DAY This parameter is used to program the current day of the growth curve function The GROWTH DAY is adjusted in 1 day increments from day 1 to day 127 For more details see User s Manual 6M70F0 Page 9 of 16 08 25 2006 F2 ADJUST DAY This is to adjust the growth day Growth day can be turned OFF or adjusted to any day value from 1 to 127 6M70F0 Page 10 of 16 08 25 2006 3 ALARM The alarm relay is normally activated but it will deactivate 2 6 seconds or more after a power failure or after one of the following events occurs a IC 610 is defective ROOM TEMPERATURE exceeds the limits ALARM HI or LO TEMP RSP