Home
Questions and Answers
Contents
1. Questions and Answers Biomedical ProSim Vital Signs Simulators Other FAQ Question Answer Question Answer Question Answer Question was demonstrating ProSim IBP simulation feature to a customer on a Philips patient monitor the IBP waveform seemed to be correct but no numerical display occurred Is there something wrong with the monitor or ProSim No Ensure both ProSim 4 or 8 and patient monitor are properly zeroed before starting the IBP simulation Below is the step by step procedure on how to properly zero both patient monitor and ProSim 8 for IBP number to display Please note the zero procedure on different patient monitors may be different Please refer to patient monitor user manual for details The example below uses HP Philips Viridia vital sign patient monitor e Connect ProSim 8 and HP Viridia monitor with proper IBP cables e Select IBP on ProSim 8 ZERO both IBP channels e OnHP Viridia select MODULE SETUP e Then select PRESS 1 ABP e Press ZERO XDUCER e ZERO IN PROCESS should display on the monitor e Initiate the ProSim 8 IBP simulation IBP numbers should display on the HP Viridia monitor need a simulator that has four or more IBP Invasive Blood Pressure channels ProSim 8 only has two channels The more IBP channels a simulator has the larger and more expensive the simulator will be The majority of our fleet of customer design partners reported they do not have to use more tha
2. n two IBP channels at the same time those who do need to test three or more IBP channels have chosen to test two IBP channels at a time then two more and so on This preference avoids that extra cost size and weight and still yields faster easier testing in the end Which 8 main parameters does ProSim 8 test ProSim 8 simulates following 8 parameters 1 ECG including normal and Arrhythmias 2 Respiration 3 IBP Invasive Blood Pressures Cardiac Catheterization 4 Temperature 5 Cardiac Output 6 NIBP Non Invasive Blood Pressure 8 Masimo Rainbow Which 4 main parameters does ProSim 4 test 6045 Cochran Rd Cleveland OH 44139 USA Tel 440 248 9300 Fax 440 349 2307 Email sales flukebiomedical com www flukebiomedical com Questions and Answers Answer Question Answer Question Answer Question Answer Question Answer Biomedical ProSim 4 simulates following 4 parameters 1 ECG including normal and Arrhythmias 2 Respiration 3 IBP Invasive Blood Pressures 4 NIBP Non Invasive Blood Pressure Why is it important to test alarms in a patient monitor Alarm hazards ranks second on the Heath Technology Hazards of 2011 The Boston Globe recently reported the death of a patient whose treatment have been delayed because a critical physiologic monitoring alarm had been turned off What are the two USB ports on ProSim 8 used for The mini B USB Device Port labeled Device unde
3. rneath the port is used to connect to a PC for remote control or download test results data toa PC USB A Controller Port labeled Host underneath the port is for external keyboard barcode reader or printer What does ACLS stand for ACLS means Advanced Cardiac Life Support ACLS ACLS algorithms includes waveforms from Ventricular Fibrillation Atria Fibrillation to Complete Heart Block What is Swan Ganz Procedure After insertion of a Swanz Ganz catheter into a vein usually the basilic vein of the forearm the catheter is gently guided by the flow of the blood into the pulmonary artery A monitor attached to the distal lumen port supplies a reading of pulmonary artery pressure PAP Pulmonary capillary wedge pressure PCWP is determined by inflating the balloon which becomes wedged when this wedge blocks blood flow it provides a reading of the pressure in the left side of the heart 6045 Cochran Rd Cleveland OH 44139 USA Tel 440 248 9300 Fax 440 349 2307 Email sales flukebiomedical com www flukebiomedical com
Download Pdf Manuals
Related Search
Related Contents
`lèchnical Furman Sound PST-10D Surge Protector User Manual Santa Rita Experimental Range Digital Database: User's Guide GRAVEUR DE DVD Case Logic LNEO-12 新事業分野開拓者認定制度 募集要項 溝掘機 OM1000A Find & Replace It! User Manual Copyright © All rights reserved.
Failed to retrieve file