Hardware Configuration Manual

image

Contents

1. The matching of power supply of switch and power required If the power switch open 7 2 Configuration System Failure After The power of VAid823It EPON OLT is on if the system works normally the booti ng information will be displayed in configuration terminal if there is failure in configurati on system it will display nothing or illegible characters 7 2 1 Troubleshooting on No Displaying After the power is on and if the configuration terminal displays nothing please examine the device as following m The power works normally m The correct connection of Console cable 232 www vaidsys ru ee Systems Hardware configuration manual If there is no problem in above examination maybe there is something wrong with the parameter configuration of the terminal such as hyper terminal or the configuration cab le 7 2 2 Troubleshooting on displaying Illegible Characters If illegible characters are displayed parameter configuration of terminal Such as hyper terminal is incorrect Please affirm parameter configuration of terminal such as hyper terminal baud rate is 9600 data bit is 8 and parity check is none stop bit is 1 flow control is none and choose terminal emulation as auto detect 33 www vaidsys ru Systems Hardware configuration manual Chapter 8 Appendix RJ 45 Connector 8 1 RJ 45 Connector 1000Base TX interface and debug network interface of VAid823It
2. EPON OLT uses RJ 45 connector Picture 9 1 describes the plug of standard RJ 45 connector and function of each pin of RJ 45 in each mode Picture 9 2 9 3 describe the connecting of parallel reticle and crossing reticle Table 9 1 describes the function of each pin of RJ 45 in MDI mode Table 9 2 describes the function of each pin of RJ 45 in MDI mode LY hr 87654521 Picture 8 2 Parallel reticle 34 www vaidsys ru es Systems Hardware configuration manual Picture 8 3 Crossing reticle Table 8 1 Pin distribution of RJ 45 MDI interface Pin 10 100Base T 1000Base T number Signal Function Signal Function 1 Tx Sending data BIDA Ato the data 2 Tx Sending data BIDA Ato the data Receiving 3 Rx BIDB B to the data data 4 Reserved BIDB B to the data 5 Reserved BIDC C to the data 6 Rx Receiving data BIDC C to the data 7 Reserved BIDD D to the data 8 Reserved BIDD D to the data Table 8 2 Pin distribution of RJ 45 MDIX interface Pin 10 100Base T 1000Base T number Signal Function Signal Function 1 Rx Receiving data BIDB B to the data 2 Rx Receiving data BIDB B to the data 3 Tx Sending data BIDA Ato the data 4 Reserved BIDC C to the data 5 Reserved BIDC C to the data 6 Tx Sending data BIDA Ato the data 7 Reserved BIDD D to the data 35 www vaid
3. Hardware configuration manual IEEE 802 3x flow control full duplex IEEE 802 1p CoS WRR SP and FIFO queue scheduling algorithm To support 802 1P DSCP priority Mark Remark Limit function based on the uplink and downlink of each ONU Support the function of the DBA and SLA stream classification Support for priority based flow mark packet redirection Limit the maximum number of users per port Port Isolation Packet storm control Security Feature ACL access control functions based on the data stream PON port to transfer data encryption Support 802 1X authentication IGMP v1 v2 v3 Multicast IGMP Snooping Multicast VLAN managed multicast Port Mirroring Support Support SNMP management support for network management system CLI Web SNMP TELNET cluster and other management methods RMON V1 group 1 2 3 9 SSHv1 v2 Through TFTP and FTP software upgrades and bootrom upgrade Configuration and Management Local or server log recording system syslog In English the command prompt Ping traceroute and other network testing tool 10 www vaidsys ru ee Systems Hardware configuration manual Debug output debug Lightning protection Service port with lightning protection ability Maintain Support Telnet remote maintenance Working temperature 0 C 45 C Working humidity 10 90 fie www vaidsys ru ee Systems www vaidsys ru aiia OS Systems
4. Parity None w Stop bits 1 v Flow control Hardware Restore Defaults Picture 5 3 Serial parameter configuration Click configure in hyperterminal attribution to configure serial interface attribute as following 26 www vaidsys ru s ee Systems Hardware configuration manual EPON Properties 2 X Connect To Settings Devon Country region United States 1 Enter the area code without the long distance prefix Area code Phone number Connect using COMI E onfigure Usec ountry region code and area code Redial on busy Picture 5 4 configure serial interface attribute in hyperterminal attribution interface After configuring serial parameter click yes to enter hyperterminal interface as following ITa www vaidsys ru ee Systems Hardware configuration manual Ose og on g Connected 0 00 25 ute Geta Ato dett ons mr Picture 5 5 hyperterminal window Choose Cattribution in typerterminal window to enter attribution window Click configure to enter attribution configuration window as in following picture Choose terminal emulation as auto detect then click yes 28 www vaidsys ru ee Systems Hardware configuration manual EPON Properties Connect To Settings Function arrow and ctrl keys act as Terminal keys O Windows keys Backspace key sends CtkH Del Ctr4H Space Ctri H E
5. the electromagnetic interference resistance ability The device attached to the chassis ground end randomly received equipment panel after grounding pole the other end of the nearest good grounding Requirements for grounding resistance less than 4 ohm If the device is mounted on the standard 19 cabinet it also requires 19 inch standard cabinet earthing 19 www vaidsys ru ee Systems Hardware configuration manual 4 3 Connect to Switch Console Port 4 3 1 Console Cable Console cable is a shield cable of 8 cores One end is crimped RJ 45 connector whi ch is inserted to Console interface the other end is a connector with DB 9 holes T he Console cable is as the following picture A Direction 8P8C PLUG magnify DBS B Direction magnify PIN 9 B f pii PIN 1 PIN 8 Picture 4 2 Console cable Table 4 1 Console cable connection RJ45 Signal Direction DB 9 1 CTS gt 8 2 DSR gt 6 3 RXD gt 2 4 GND 5 5 GND 5 6 TXD 3 7 DTR 4 8 RTS lt 7 20 www vaidsys ru ee Systems Hardware configuration manual 4 3 2 Connect to Console Port After configuring the device the steps of cable connection as below Step 1 Put DB 9 to the configured host or console Step 2 Connect RJ 45 to console A Caution Please recognize the interface identification to avoid inserting the other interfaces b
6. 2 1 Temperature Humidity To guarantee normal working and life span of the switch certain temperature and humidity can be maintained in the equipment room If the humidity is to o high the insulating of insulating material may be not good even creepage and sometimes may cause the change of mechanical performance and rustin ess of metal parts If the related humidity is low the insulated gasket will be shrinkable which will cause the looseness of captive screw In the dry climat e electrostatics may be caused which is harmful for the CMOS circuit of swit ch The higher the temperature is the more dangerous it is It will greatly re duce the reliability of the switch and long term high temperature will affect th e life span of the switch Over high temperature may accelerate the aging of the insulated materials 3 2 2 Neatness Dust is harmful for the operation of the switch The dust in the room fell on the equipment may cause the absorption of the electrostatics which may influ ence the life span of the switch and cause the communication failure The re quirement for the dust and the grin size is as following Table 3 1 The requirement for the dust in switching room The maximum thickness the 1 4x107 2 4x10 1 3x105 14 www vaidsys ru ies Systems Hardware configuration manual Besides dust switching room also strictly requires the content of salt acid and sulfide This harmful gas may accelerate the rusting and agin
7. 2 3 EPON OLT back panel 1 2 power input options 2 ground column A Caution EPON OLT supports AC and DC DC AC or single DC or single AC 2 3 2 Optional power The VAid823It EPON OLT Optional support dual AC power input dual DC power input AC DC power input 2 4 VAid823It EPON OLT System Features Table 2 4 EPON OLT system features Items VAid823lt Size WxHxD 1RU Cassette 442mm L x315mm W x44mm H Weigh lt 3kg Input voltage AC 90V 240V 47 63Hz www vaidsys ru ais Systems Hardware configuration manual DC 36V 72V Max power consumption lt 32W 8 GE Combo ports Port 8 PON port Switching mode Store and forward Store and forward Switching capacity 32Gbps IEEE 802 3ah EPON IEEE802 3 10Base T IEEE802 3u 100Base TX IEEE802 3z 1000BASE X IEEE802 3ab 1000Base T IEEE802 1Q VLAN IEEEE802 1d STP Standard IEEEE802 1W RSTP IEEEE802 1S MSTP IEEE802 1p COS IEEE802 1x Port Control IEEE802 3x flow control IEEE802 3ad LACP Each OLT interface hangs up to 64 ONU Each OLT transmission distance is up to 20Km VLAN QinQ Link aggregation broadcast storm control Layer 2 feature Support up to 4096 VLAN Support 16K MAC address table Supports bandwidth control Aggregation group 127 groups of up to eight members To support entrance egress ACL ACL QOS Back pressure flow control half duplex www vaidsys ru es Systems
8. FP ports and eight Gigabit Combo ports Table 2 2 EPON OLT SFP selected module description SFP module Center wavelength Connector Fiber interface Maximum name types of fiber specification transmission interface distance of optical fiber Receive 1310nm Single mode SFP EPON LH10 10km send 1550nm T fiber Receive 1310nm Single mode SFP EPON LH20 20km send 1550nm fiber Table 2 6 GE SFP interface selected module description SFP module name Center Connector Fiber interface Maximum wavelength types of fiber specification transmission interface distance of optical fiber Multimode SFP GE SX MM850 850nm f 550m fiber SFP GE SM1310 LH10 10km SFP GE SM1310 LH20 1310nm LC 20km Single mode SFP GE SM1310 LH40 fib 40km iber SFP GE SM1550 LH40 40km 1550nm SFP GE SM1550 LH60 60km Li Caution The module types of GE SFP updates when the time changes so if you need the accurate module type information please require the marketing of New 2 3 VAid823It EPON OLT Back Panel 2 3 1 Back Panel www vaidsys ru ee Systems Hardware configuration manual The VAid823It EPON OLT rear panel as shown below comes standard with an AC 220V power supply interface Supported by the device according to the user needs to modify the power supply module configurable dual AC or dual DC power supp ly can also be modified for single DC power supply Picture
9. Hardware configuration manual Chapter 3 Installation Preparation 3 1 Security Notice To avoid device damaging and bodily injured caused by unsuitable operation please follow these notices Before cleaning switch pull out the plug of switch Do not wipe it with wet cloth and liquid Do not locate switch near water or humid place and prevent water and humidity entering switch Do not locate switch on unstable case or desk Falling may cause severe damage to switch m Keep the ventilation of the room and the switch Switch can work normally under correct power pressure Please affirm the power pressure of switch is the same as that marked To avoid the danger of electricity attacking do not open the cabinet shell though the switch is power off 3 2 Examine Installation Location VAid823lt EPON OLT must use indoor no matter install in the cabinet or put the pla tform directly it should ensure below conditions 13 www vaidsys ru Systems Hardware configuration manual Make sure there is space between the wind inlet and vents to hot dissipation Make sure the cabinet or platform has the good vents dissipation system Make sure the cabinet or platform is firmed to bear the device weight Make sure the cabinet or platform is connected to the ground To ensure the device works normally and prolong the service life the installation en vironment also need to fulfill the below requirements 3
10. aration ccc ccecccscsecescseesscseeseeseseceecseeseees 13 3 1 Security Notice 0 sscsceccescesssssmesesenspnsessasnyesoesesatgnsntnscbssovsvssghaessneescoes 13 3 2 Examine Installation Location eee ceeecceeseceesecseeeeeeseeseneeeetens 13 3 2 1 Temperature HUMIILY 0 ee ceeceseeceeeeeeeeeeeeseeeeseeeceeeeenees 14 3 2 2 INGA GSS os s5 ca cesbteecsees E A ENEE 14 3 2 3 Immunity requireMent cece cceeeeteceeecetetseeeteeeneeseeeees 15 3 3 Tools for Installation ce ccsesecsesesesenseseecseseecesesseeecseasseaeeesaeecneneeees 16 Chapter 4 Installation ececesescesesesceseeeeseseseeceeeseecsesceescseneeeeeeaeeeeeeeeataees 17 4 4 Installation Step cece cesesensesesesenseecscseseeesessssesesessesesseaneenens 17 4 1 1 Install tothe RACK sisccdiiancicias daca aica ates 17 www vaidsys ru ee Systems 4 1 2 Install to the Platform cseeseeescreseeeeeeeeneeesaesenes 18 4 2 Connectto Ground cuiccsiiiniinaaasiasdoniusinaestenseaniee 18 4 2 1 AC power Installation ccccccscessescssseseeseeeeseeseeeeneenes 19 4 2 2 DC power Installation ccc ccecesecseeeceeeeseeeeeecsecseeeeeaes 19 4 2 3 Connect to Ground cece ceeteeenseseeceneeesscaseetesesaeeenes 19 4 3 Connect to Switch Console Porta ce eeeecsseseceeeceeeecseeeceeneeseeeees 20 4 3 1 Console Cab 6 c c0e5 a eeviiseeetshu heeriloninn Sikeniee aus 20 4 3 2 Connect to Console Porta eececeeesceeeceeteeeee
11. ared by user 16 www vaidsys ru cs OS Systems Hardware configuration manual Chapter 4 Installation A Caution There is an anti dismantle seal remarked New on the installation screw outside the case When the agents maintain the device it is required that seal is entire So before user opens the device please get the permit from local agent or user will take the responsibility with unauthorized operation maintenance 4 1 Installation Step 4 1 1 Install to the Rack VAid823lt EPON OLT can install on the rack the process is as below Step 1 Examine grounding and stability of the cabinet Use screw to fasten hanger to the two sides of the front board and back board of the switch Step 2 Locate switch on the salver of the cabinet Move it to the suitable location along with the slide of the switch Keep some space between switch and the slide Step 3 Fasten hanger to the fixed slide of the cabinet to guarantee the bracket of eac h slot and hanger of the switch are fastened to the cabinet 17 www vaidsys ru Systems Hardware configuration manual Figure 4 1 EPON OLT installation am Caution The fixed angle iron is only for fixation not for load bearing The device install on the cabinet slide fix on the cabinet under the device is to bear the weight 4 1 2 Install to the Platform At more situations users always put the device to the clear platform The operation is simple please be noted of be
12. d also u pload configuration files by xmodem tftp and ftp 1 Upload configuration file through TFTP refer to software configuration manual 2 Download configuration file through TFTP refer to software configuration manual 3 Download application file through TFTP refer to software configuration manual Download application file through TFTP The command is load application tftp fftp server filename Download application file through TFTP Step 1 Enable TFTP server and configure download destination path Step 2 Imput TFTP download command Example Download application program app arj from IP address 192 168 0 100 Enabl e TFTP server and configure download destination path Configure it in privileged mod e Optiway load application tftp 192 168 0 100 app arj There will be displaying as following if succeed Application file has been downloaded via tftp successfully The new application will not be effective until the device is rebooted A Caution The new application will not be effective until the device is rebooted 2011 All Rights Reserved 31 www vaidsys ru es Systems Hardware configuration manual Chapter 7 Troubleshooting 7 1 Power System Failure VAid823It EPON OLT can check the power system failure according to the power indicator on the front board when the power system works normally the power indicator keeps on if it is off please examine as following m The correct connection of power wire
13. etect The configuration is as following 93 3 www vaidsys ru Systems Hardware configuration manual 6b Click start program accessory communication hyperterminal to set up new con nection System will display interface as following Input the name of the new conne ction in name such as EPON Connection Description ai New Connection Enter a name and choose an icon for the connection Name EPON Icon SSo3euk Lilt Picture 5 1 Explanation of hyperterminal connecting interface Click yes to the interface connecting to as following Choose serial interface used by connect ion in use in connection 94 lt www vaidsys ru ee Systems Hardware configuration manual Connect To D EPON Enter details for the phone number that you want to dial t Country region ted States 1 Area code a Phone number Connect using COM1 Picture 5 2 Configuration of using serial interface in hyperterminal After choosing serial interface click yes to display corresponded serial attribution interface as followi ng Configure baud rate to be 9600 data bit to be 8 parity check is none stop bit is 1 flow control is none 25 www vaidsys ru ee Systems Hardware configuration manual COM1 Properties x Fort Settings Bits per second 9600 Databits 8 M
14. figuration manual Chapter1 Product Introduction 1 1 VAid823lt EPON OLT Introduction VAid811It has two three speed forwarding capability used primaril y for industrial electricity networks in the field of digital management works for the National Grid distribution automation and electricity infor mation collection to provide comprehensive intelligent strong advanc ed professional solution Splitting ratio of up to 1 64 mixed networkin g support different types of ONU operators investments do minimized 1 2 VAid823lt EPON OLT Typical Application The VAid823It typical networking is as shown below www vaidsys ru ee Systems Hardware configuration manual Distribution management Distribution room Apartment master station Electric meter Intelligence exchange terminal Pc i AR If Distribution room om oe 4 eases sth paa Convertin ng stati n 1 32 FT Intelligence appliance i S 3 b i RF Termin l toe oo gt E 1 32 Splitter cia hi z Master station 485 Electric meter BAPS SDH MSTP Intelligence exchange terminal Pc 5 1 32 Monitoring 1 32 Splitter Bar t eee i ws 485 Bus Intelligence appliance Distribution room 5 Sustauion x sf ee onverting station T T 485 Electric meter Chapter 2 Specifications and features 2 1 VAid823It EPON OLT appearance Picture 2 1VAid823lt EPON OLT appearance www vaidsys ru 2 2 VAid823It EPON OLT Front Pane
15. g of same parts Such harmful gas must be prevented as SO2 H20 NO2 NH3 and CL2 The restricted value is as following Table 3 2 The limitation of harmful gas Average mg m Maximum mg m ee a ee 3 2 3 Immunity requirements In the use of equipment may be derived from the system external interference such interference by capacitive inductive coupling electromagnetic radiation public impedance including the grounding system coupling and wires power line the signal lines and the output lines conduction mode on the equipment influence Therefore we should pay attention to AC power supply system for TN system AC power source socket should be equipped with protective earth PE of single phase three wire power supply socket so that the device can effectively filter the filter circuit interference of electric network Equipment location away from the high power radio transmitter radar transmitter high frequency large current device Necessary to take the electromagnetic shielding method such as interface cable with shielded cables 15 www vaidsys ru ies Systems Hardware configuration manual 3 3 Tools for Installation Tools needed Cross screwdriver m Antistatic wrist strap m Wire stripper Cable needed m Power cable m Console cable m RJ 45 connector reticle Device needed Configuration terminal can be PC A Caution EPON OLT doesn t provide installation tools which are prep
16. l 2 2 1 Front Panel Systems Hardware configuration manual VAid823It EPON OLT front panel are arranged as shown in the following diagram the front panel contains 8 Gigabit Combo ports and 8 PON port a number of LED in dicators a console port and an AUX port Picture 2 2 VAId823ItEPON OLT front panel The front panel LED indicator label are described in Table 2 1 Table 2 1 EPON OLT master card front panel indicator Indicator Panel Status Meaning Indicator Flash System operates normal Always SYS on or System operates abnormal Always off Always System power supply is System status on normal lights PWR1 Always System power failure off Always System power supply is on normal PWR2 Always i System power failure 0 www vaidsys ru ies Systems Hardware configuration manual System power supply is on PWR normal off System power failure on Debug mode is turned on AUX off Debug mode is turned off on Connection is normal Port LEDs GE Flash Send or receive data off Port is not connected ONU registration on the PON on port REG m The PON port no ONU fe registration on PON indicator The port ongoing data on transceiver ACT m The port is not performing 0 data transceiver www vaidsys ru ies Systems Hardware configuration manual 2 2 2 EPON OLT SFP Port Feature The VAid823lt OLT front panel 8 PON OLT S
17. low steps Make sure the platform is stable and good connected to the ground Leave 10cm space for the heat dissipation around the device Don t put the heavy things to the device 4 2 Connect to Ground VAid823It Epon oLt adopts hot swappable power box It also supports AC and D C power backup for each other mixed mode There are two kinds of power box AC and DC the range of power is AC 100V 240V 18 www vaidsys ru es Systems Hardware configuration manual DC 36V 72V 4 2 1 AC power Installation 1 The input range of AC 100V 240V 50 60Hz AC 2 Connect to the AC power cord The device randomly with the power line is inserted into the enclosure on the rea r panel of the power socket another end is inserted to provide AC power outlet 4 2 2 DC power Installation 1 The input range of DC 36V 72V DC 2 Connect to the DC power cord Plug the DC power cord into outlet on the rear panel the other end red wire inserts into the DC power positive electrode black wire inse rts to the DC power negative electrode 4 2 3 Connect to Ground A Caution The device well connected can protect switch from lightning and jamming user must correctly connect the ground carefully VAid823It EPON OLT power supply input end connected with noise filter which is directly connected with the chassis protection so it must be well grounded so that the induction electric electric leakage can be safely into earth and improving
18. mulation l Auto detect v Telnet terminal ID ANSI Backscroll buffer lines 500 C Play sound when connecting or disconnecting Input Translation ASCII Setup x Cera Picture 5 6 Configuration of terminal emulation in attribution configuration 5 2 Booting 5 2 1 Examine before the power on Examine as following before the power of VAId823ItEPON OLT is on The correct connection of power wire The consistency of the power supply and the power that switch needed The correct connection of configuration cable The terminal or PC for configuration has been configured 29 www vaidsys ru ee Systems Hardware configuration manual 5 2 2 Booting After the power is on followings will be displayed Username 1 32 chars Input username and press enter button The prompt of inputting password is as foll owing Password 1 16 chars After inputting password followings are displayed Optiway gt At this time user can check and configure system information of device 30 www vaidsys ru cs OS Systems Hardware configuration manual Chapter 6 Software Upgrade General software upgrading uses serial interface which is very slow cost long time and inconvenient VAid823It EPON OLT introduces xmodem tftp and ftp to realize the conv enience of software upgrading and file downloading EPON OLT can upgrade application program on line load configuration file by xmodem tftp and ftp an
19. orange 4 blue 4 blue 5 white blue 5 white blue 6 green 6 orange 7 white brown 7 white brown 1234 5678 8 brown 8 brown SIDE2 Picture 8 5 Make crossing reticle 37
20. seecneeeeneeeens 21 44 Check after the Installation eee cneeeeeeecseeeteseeseeeenaeeenes 21 Chapter 5 Booting and Configuration 0 cccccccecsessccseseesseseesesscsseseeeees 23 5 1 Local terminal Configuration 0 cccccecceseeeeeesseeesestecseeeeeteeseeeeees 23 5 1 1 Configuration environment 23 5 1 2 Connect configuration Cable ccc cccceeseeeeteeeeeeneees 23 5 1 3 Configure terminal parametel cece eeeereeeeees 23 5 2 BOON seictestcvssessexsavvesct ops occnhadsssusvsshscesitvesnssssasescetcloxpuenedes iedoudesdhjensubeoroaes 29 5 2 1 Examine before the power ON eeeceeseeeseeeeeeeeeeseneeeees 29 5 2 2 BOO Deene cotentaripaisidensseve abs 30 Chapter 6 Software Upgrade ccc cccccccscsecsscscesscscsseescseceecsscsecsecsesseeseeeees 31 Chapter 7 Trouble SHOOtING ceeeceeeceseeeeeeseeeseeeseeceecaeeceeeeeseseeeeetseeeaeeeeatees 32 7 1 Power System Failure ce ccecssescseeseseeseeeseeeeseeeeaeeecaeeecaeeecaeeeeaeeeeaeeas 32 7 2 Configuration System Failure ee eeeeeeceseeeeeeceeeceeeeeeneeeeeeeenees 32 7 2 1 Troubleshooting on No Displaying 32 7 2 2 Troubleshooting on displaying Illegible Characters 0 ee 33 8 1 RI 45 COnne Ctl ci0 cess torind es a AEREE E 34 8 2 Make the Cable cecccecccssessseseseesesceseceeeseeeeeeceeseceesecseeecaeeesaeeeseeeeeeeees 36 www vaidsys ru cs OS Systems Hardware con
21. sys ru Systems Hardware configuration manual 8 Reserved BIDD D to the data 8 2 Make the Cable Appendix picture 2 is the example of making Ethernet cable of RJ 45 connector by usi ng categories 5 twisted pair Blue Pair 1 White Blue Pair 2 __ Orange White orange _ Green Pair 3 hi te green oo Brown Pair 4 whi te brown Picture 8 4 The picture of categories 5 twisted pair Categories 5 twisted pair consists of 8 core filament with the color on the insulated laye r being grouping sign Usually it uses a single color and single color with white to be a pair of standard and sometimes uses color points to be a pair of sign Here take th e former as an example Categories 5 twisted pair consists of 8 core filament with the color on the insulated laye r being grouping sign Usually it uses a single color and single color with white to be a pair of standard and sometimes uses color points to be a pair of sign Here take th e former as an example 36 www vaidsys ru Systems Hardware configuration manual SIDE1 SIDE 1 SIDE 2 1 234 5678 1 white orange 1 white orange 2 orange 2 orange 3 white green 3 white green 4 blue 4 blue 5 white blue 5 white blue 6 green 6 green 7 white brown 7 white brown 1 23 45678 8 brown 8 brown SIDE2 Picture 8 5 Make parallel reticle SIDE1 SIDE1 SIDE2 1234 56 78 1 white orange 1 white green 2 orange 2 green 3 white green 3 white
22. www vaidsys ru es Systems VAid823Ilt EPON OLT User Manual Hardware Configuration Manual 1 Product Introduction 2 Specification and Features 3 Installation Preparation 4 Installation 5 Setup and Configuration 6 Update Software 7 Troubleshooting oe Optional interface module o Appendix RJ 45 Connector www vaidsys ru ee Systems Content Chapter1 Product INtroduction cccccccccsecseescesessccsesecseeseesesscesesecsecseeseesees 3 1 1 VAId823It EPON OLT Introduction cececeeseeseseeeeteeeeeesteeeeeeneneees 3 1 2 VAid823It EPON OLT Typical Application ceececeeeeteereeeeeees 3 Chapter 2 Specifications and features ccc cccccessscescsecsecseeseceesseeeeseeees 4 2 1 VAIdB23It EPON OLT appearance seses 4 2 2 VAid823lt EPON OLT Front Panel cccceceseeceseseeseseseseenenesestees 4 2 2 1 From Pane escsscscsciscescecesexsss a 5 2 2 2 EPON OLT SFP Port Feature 7 2 3 VAid823It EPON OLT Back Pannel c cccccccccsecseseseseteseseseteeseeees 7 2 3 1 BACK Pein leccesscescteretstscacecsSatzecteuencttantas eaptectencer eeveistonianianmess f 2 3 2 Optional POWED ccecccecssesceesssescescsseeeseecsecsesessecseceesaeeaeees 8 The VAid823It EPON OLT Optional support dual AC power input dual DC power input AC DC power input uu cess eeecnecneeeeesecseseeeecsaecaeeecerenaeeeteees 8 2 4 VAid823It EPON OLT System Features 8 Chapter 3 Installation Prep
23. y mistake 4 4 Check after the Installation e Check the selected power is the same as identification power or not e Check the ground wire is connected or not e Check the console power input cable are connected or not 9il www vaidsys ru ee Systems www vaidsys ru cs OS Systems Hardware configuration manual Chapter 5 Booting and Configuration A Caution EPON OLT can provide two ways of configuration for users First Local terminal configuration Terminal can be PC connects to the Console by serial interface Second Terminal Telnet configuration Configuration terminal connects to device by IP network Pay attention to configure IP address net mask before using Telnet terminal 5 1 Local terminal configuration 5 1 1 Configuration environment Use configuration interface cable connect Console interface to terminal such as P 5 1 2 Connect configuration cable Step 1 Connect DB 9 connector to PC or serial interface of terminal Step 2 Connect RJ 45 to Console of the switch 5 1 3 Configure terminal parameter Step 1 Boot PC and run terminal emulation program such as hyperterminal in Win dows Step 2 Configure terminal parameter take the configuration of parameter ofhyperter minal in Windows 2000 as an example Parameters are baud rate is 9600 data bit is 8 and parity check is none stop bit is 1 flow control is none and cho ose terminal emulation as auto d