1. Mitsubishi General Purpose Programmable Controller Renewal Tool Conversion Adapter Models ERNT ASQT62DA ERNT ASQT68DA User s Manual ERNT ASQT62ZDA ERNT ASQT6GDA 50CM D180090 C 1409 SAFETY INSTRUCTIONS Always read these precautions prior to use Before attempting to use the Conversion Adapter or the Products read all instructions contained in this manual carefully to ensure safe and correct operation The safety instructions appearing in this manual are limited to those that apply to the Products For safety instructions to be heeded in regard to your programmable controller system as a whole refer to the user s manual supplied with the MELSEC Q Series CPU module you use In this manual the safety precautions are ranked as Warning and Caution Indicates an immediately hazardous situation which if not Z WARNING properly dealt with will result in death or serious injury Indicates a hazardous situation which if not properly deal with N CAUTION will result in moderate or mild injury or property damage alone eS lees ee Even a safety instruction marked with Caution could have serious consequences under certain conditions All the safety instructions regardless of their classification of criticality carry important points to be noted Observe them without fail Save this manual for reference when needed while at the same time ensuring that it i
2. Vibration IEC 61131 2 Under 5 to 8 4Hz 4 75mm continuous y vibration 8 4 to 150Hz 4 9m s Compliant with JIS B 3502 and IEC 61131 2 147 mis 3 times each in 3 directions X Y Z Operating atmosphere No corrosive gases Operating altitude 1 0 to 2000m Installation location Inside a control panel Overvoltage category 2 Il or less Pollution degree 3 2 4 Do not use or store under pressure higher than the atmospheric pressure of altitude Om 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities 3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally Shock resistance 3 Product Specifications For detail specifications which do not appear in the specification comparison charts contained herein see the user s manual supplied with the MELSEC Q Series module you use Those parts of the specification that differ between the MELSEC AnS Series and the MELSEC Q Series are where a switch from the first series to the second is subjected to
3. 8000 12000 10V IS User range 4000 to 4000 0 75mV 12000 to 12000 0 333mV Digita 4000 8000 12000 20ma setting E input 2000 4000 6000 12ma fe 0te20mA oto 4000 SpA Oto 12000 1 S6uA 8 value o a o ama E 4 to 20mA 4uA 1 33pA m 3 User range 4000 to 4000 4 5pA 12000 to 12000 0 83pA setting Voltage Output Current Output Maximum resolution 774000 _2 5mV 10V SuA 20mAy 1 8000 1 25MV 10V 2 5yA 20mA 4 1200 0 83mV 10V 1 7uA 20mA Ambient temperature 2545 C Within 0 1 Voltage 1 0 100mV Voltage 10mV Current 20pA Current 1 0 200pA Ambient temperature 0 to 55 C Within 0 3 Voltage 30mV Current 60uA Overall accuracy Maximum Maximum 25 ms 2 channels 80 us channel conversion time same for 1 channel Absolute maximun Voltage 12 V 12 V output Current 28 mA 21 mA Analog output points 2 channels module 2 channels module Between the output terminal and Photocoupler insulation Photocoupler insulation programmable Insulation controller power method Between channels Non insulation Non insulation Between extemal supply power and Transformer insulation analog output No of occupied points 32 points 16 points Connected terminal block 20 points terminal block 18 points terminal block Current cons
4. Eier rer TB13 ope VE TB13 ouy VH TESTET TB14 COM TB14 COM fTB19 TB15 Vail TB15 Veit TB2 1 TB16 H com TB16 H8 com i TB17 opg Vt TB17 24V f zavoc TB18 COM TB18 24G EDH TB19 Open 24V f TB20 FG 24G iF l E gt x FG terminal 1 X i Q68DAVN and Q68DAIN are not provided with a terminal for Output Hold Clear setting purposes Make Output Hold Clear setting by choosing an appropriate Q68DAVN Q68DAIN intelligent function module switch setting For details about Output Hold Clear setting see the Q68DAVN Q68DAIN User s Manuals Disconnect the FG wire from the FG terminal TB20 of A1S68DAV A1S68DAI and reconnect it to the FG terminal at the bottom of Q68DAVN Q68DAIN Q68DAVN Q68DAIN requires power supply Therefore use the opened terminal TB19 and the FG terminal TB20 of A1S68DAV A1S68DAI to provide 24VDC power supply to Q68DAVN Q68DAIN lt Specification Comparison Chart gt Item A1S68DAV Q68DAVN Signed 16 bit binary Signed 16 bR binary Digital input cab oust normal resolution mode 4096 to 4095 high resolution mode 12288 to 12287 16384 to 16383 Aisian ai 10 to 0 to 10V DC 10 to 10V DC oe External load resistance 2kQ to 1MQ External load resistance 1kQ to 1M0 Digital input Analog output Analog Normal resolution mode High resol
5. For detail information see the user s manual furnished with the MELSEC Q Series CPU module you use 4 3 Installation Environment 5 Part Names and Installation Procedure Base Adapter attaching screw M5 x 12 supplied with Base Adapter Mounting bracket retaining screw Ma5 x 6 Gupplied with Conversion Adapter Conversion Adaptor attaching screw M3x25 MELSEC AnS Series terminal block attaching screw M4 MELSEC Q Series Base module Compatible module under Base Adapter MELSEC O Series Mounting bracket Supplied with Conversion Adapter If the existing system is installed on a DIN rail the Base Adaptor is not Conversion Adapter necessary The MELSEC Q Series HEUSES Ana Sais Base Module you use can be terminal block mounted onto the DIN rail Take note that a DIN rail installation adaptor made by Mitsubishi is required to mount MELSEC Q Series Base Module onto a DIN rail The separately sold Conversion Adapter DIN rail Mounting Bracket ERNT ASQDINO D is required to use the Conversion Adapter with a fixture on this Base module MELSEC AnS Series terminal block cover Supplied with Conversion Adapter 5 1 Installation Procedure 1 Secure the MELSEC Q Series Base Module to the Base Adapter with the supplied attaching screws M4 x 10 Secure it in four places 2 Mount a compatible module under the MELSEC Q Series onto the
6. rail 2 g G Ss s 4 2 Instructions for Use Item Description Width dimension Because the module is reduced in width dimension 34 5mm 27 4mm and thus in of module area available for wiring check dimensional data before installing the module lt MELSEC AnS Series gt lt MELSEC Q Series gt ga ed Unit mm Item A1S68DAI Q68DAIN Signed 16 bit binary normal resolution mode 4096 to 4095 Signed 16 bit binary high resolution mode 12288 to 12287 16384 to 16383 Digital input urns 4 to 20mA DC 0 to 20mA DC Analog output External load resistance 0 to 6000 External load resistance 0 to 6000 Digital input Analog output Analog Normal resolution mode High resolution mode value value output Digital input Maximum Digital input Maximum VO characteristics 4000 20mA range value resolution value resolution 2000 12mA Oto 20M 5pA 1 66pA 0 AmA Ao amaj 2O00 4pA 9 19 12000 7 330A User range Fammen mA vatima 4000 0 4000 1 5uA 12000 to 12000 0 83 Ambient temperature 2545 C Within 0 1 20pA Overall accurac 1 0 4200pA matty if a200n4 Ambient temperature 0 to 55 C Within 0 3 60uA Maximum Maximum 4 ms 8 channels 80 us channel conversion time Absolute maximun output x 21mA Analog output points 8 channels module 8 channels module Between the output terminal and Photocoup
7. MELSEC Q Series Base Module Also remove the terminal block installed to the MELSEC Q Series Module by undoing the terminal block attaching screws one at the top and the other at the bottom _ MELSEC Q Series terminal block attaching screw Secure it in two places top and bottom 3 Secure the mounting bracket to a compatible module under the MELSEC Q Series with retaining screws M3 5 x 6 Secure it in two places top and bottom 4 Mount the Conversion Adapter onto the mounting bracket and secure it with the Conversion Adapter attaching screws M3 x 25 Secure it in two places top and bottom Precaution Before tightening the installation screws check that the Conversion Adapter has been securely installed on the MELSEC Q Series module Tightening the screws in floating off state or tilting state will damage the Conversion Adapter installation screws and the mounting bracket 5 Secure the Base Adapter to the panel with the supplied attaching screws M5 x 12 Secure it in four places 6 Secure the MELSEC AnS Series terminal block to the Conversion Adapter with the supplied attaching screws M4 7 Remove the terminal block cover from the MELSEC AnS Series terminal block and fit the terminal block cover supplied with the Conversion Adapter in place 5 2 Tightening Torque Tighten the module attaching screws by applying
8. all the Unit or carry out the necessary wiring make certain that the external power supply used in the system is shut off on all three phases Failure to do so may result in electric shock or damage to the product Do not touch live terminals There is a danger of electric shock or malfunction Do not modify the Conversion Adapter or take it apart Doing so will cause failure malfunction personal injury or fire 4 Do not touch the energized part of the Conversion Adapter directly Contact will cause malfunction or failure in the system Fasten the Conversion Adapter and the Fittings securely with retaining screws and tighten the screws by applying torque within specified limits Loose screws can lead to the dropping of the converter adapter or fittings possibly causing breakage thereof Excessive tightness of the screws can lead to breakage of the screws converter adapter fittings or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof Use care to prevent foreign materials including cuttings and wiring debris from entering the Conversion Adapter or the MELSEC Q Series module These will be cause for fire failure or malfunction 7 Do not drop the Conversion Adapter and Fittings and avoid giving a strong impact to them Otherwise breakage will result If the existing system is installed on a DIN rail the Base Adaptor is not necessary The MELSEC Q Series Base Module you use can be mounted onto the DIN
9. e switch setting For more details about the Offset Gain setting and Output Hold Clear setting see the Q62DAN User s Manual Q62DAN requires power supply Therefore use the opened terminals TB18 TB19 of A1S62DA to provide 24VDC power supply to Q62DAN Be sure to establish a ground for the FG terminal TB18 of Q62DAN using the open terminal TB20 of A1S62DA lt Specification Comparison Chart gt ltem A1S62DA Q62DAN Signed 16 bit binary Voltage Output Current Output Signed 16 bit binary Digital input 1 4000 4000 to 4000 0 to 4000 normal resolution mode 4096 to 4095 1 8000 B000 to 8000 0 to 8000 high resolution mode 12288 to 12287 16384 to 16383 4 12000 42000 to 12000 0 to 12000 PN 10 to 0 to 10V DC 10 to 10V DC ii External load resistance 2k to 1MQ External load resistance 1k to 1MQ Analog output Aaa 0 to 20mA DC 0 to 20mA DC External load resistance 00 to 6000 External load resistance 0 to 6000 Analog Resolution 13000 1780001112000 output Normal resolution mode High resolution mode value Analog output range Digital input Maximum Digital input Maximum 2 Digital aaea ma aa ie value resolution value resolution 2 Oto 5V 1 25mV 0 416MV O characteristics 3 mot o 0 o ov f itos 214000 fiom t 12000 o 333mv gt value 2000 4000 6000 5v S 10 to tov 2 5mV_ 16000 to 16000 _0 625mV 4000
10. e their products are compliant to the EMC and Low Voltage Directives are required to declare that print a CE mark on their products Authorized representative in Europe Authorized representative in Europe is shown below Name Mitsubishi Electric Europe BV Address Gothaer Strasse 8 40880 Ratingen Germany REVISION HISTORY Date of print Number of User s Manual Description Apr 2011 50CM D180090 A The first version is printed Apr 2014 50CM D180090 B Description of Base adapter deleted Correction SAFETY INSTRUCTIONS Chapter 3 4 5 6 Addition Chapter 2 September 2014 50CM D180090 C Correction Section 2 Nothing herein shall be construed as Mitsubishi s guarantee for or endorsement of the implementation of any industrial properties or other rights by any party or as granting any party a license for the use of such properties or rights Mitsubishi shall not be liable for any problems whatsoever which pertaining to such properties or rights arise out of the use of what is described herein 2011 MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED TABLE OF CONTENTS SAFETY INSTRUCTIONS EMC AND LOW VOLTAGE DIRECTIVES REVISION HISTORY STABLE CORI ONTENTS sear ieee aera ease aera ea saa es ND ates ahaha nN General Description General Specifications Product Specifications Mounting and Installation etetett ttet eee teeta nee nenteneeneeeenseneeeeenensensenesersenensentens 7 Part Names and I
11. ler insulation Photocoupler insulation ___ programmable Insulation controller power method Between channels Non insulation Non insulation Between external supply power and Transformer insulation analog output No of occupied points 32 points 16 points Connected terminal block 20 points terminal block 18 points terminal block Current consumption 0 85 A 0 38 A External supply Voltage 5 24V DC 20 15 power Current B 0 27A 1 A1S68DAI and Q68DAIN differ from each other in the way input output signals X Y and buffer memory addresses are allocated Therefore you need make necessary changes to the sequence program that is used Depth dimension Because the module is increased in depth dimension check dimensional data before of module installing the module MELSEC Q Series Conversion Adapter Base Adapter 110 1575 Increased by 47 5mm Unit mm 7 Item Description Terminal block The terminal block cover for MELSEC AnS Series is bigger than the width of the cover MELSEC Q Series Module Therefore it is necessary to replace it with the terminal block cover supplied with the converter adapter lt MELSEC AnS Series gt lt MELSEC Q Series gt Terminal block cover for the MELSEC AnS Series Replace the terminal hk block cover with the N one supplied with the Conversion Adapter 5 Unit mm
12. nd snagged on the fittings or the like Injury may result When installing or removing the MELSEC Q Series Module complete with a converter adapter be sure to hold it with both hands Dropping may lead to breakage iring Precautions Before attempting to install the Unit or carry out the necessary wiring make certain that the external power supply used in the system is shut off on all three phases Failure to do so may result in electric shock or damage to the product When energizing the Products or putting them into operation after the completion of installation or wiring work always have a cover placed over the terminal block for the MELSEC AnS Series components Without the cover placed in position electric shock can result Ground the FG terminals to the protective ground conductor dedicated to the programmable controller Failure to do so may result in electric shock or malfunction Carry out wiring for the Conversion Adapter correctly after checking the specification and terminal arrangement for the module used Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure Tighten the MELSEC AnS Series terminal attaching screws and terminal screw secirely by applying torque within the specified limits Loose screws will cause short circuit fire or malfunction Excessive tightening will damage the screws or the Conversion Adapter which in turn will cause dropping of parts
13. nstallation Procedure Dimensional Outline Drawing a E adi ai A 3 1 General Description This manual provides information about the Conversion Adapter ERNT ASQT62DA ASQT68DA available as Renewal Tools for the Mitsubishi General Purpose Programmable Controller The Conversion Adapter is a product for effecting conversion to transcend difference in pin assignment between the MELSEC AnS Series and the MELSEC Q Series Before attempting to make a switch from MELSEC AnS Series to MELSEC Q Series in your installation consult the user s manual supplied with individual module under the latter series to learn about how they differ in various aspects including performance and function Upon unpacking your Adapters check to see that the following items are included in their shipping carton Item name Quantity Adapter sl Fittings 1 Fittings attaching screws M3 5 x 6 2 Terminal block cover i 2 General Specifications Item Specifications Operating ambient temperature Storage ambient temperature Operating ambient humidity Storage ambient humidity 0 to 55 C Maximum surrounding air temperature 55 C 25 to 75 C 5to 95 RH non condensing Constant Half acceleration amplitude Under 5 to 8 4Hz 3 5mm 10 times each in intermittent xX Y Z directions Frequency Sweep count Compliant with 2 resistance JIS B 3502 and Vibration 8 4 to 150Hz 9 8m s
14. other work carried out by the user es in Product Specifica The specifications given in the catalogs manuals and technical documents are subject to change without notice This document is a new publication effective September 2014 Specifications are subject to change without notice Developed September 2014 50CM D180090 C
15. s always passed on to the ultimate user Precautions Prior to use When making a switch from the MELSEC AnS Series to the MELSEC Q Series be sure to consult user s manual supplied with individual module under the MELSEC Q Series to confirm differences in various aspects including performance and function between the two series Installation Precautions Use the Conversion Adapter in the environmental conditions that are specified in the general specification If the Products are used in any environment beyond the bounds of the general specification electric shock fire malfunction or damage to or degradation of the Products will result Do not touch live uninsulated part directly Contact will cause malfunction or failure in the system Fasten the Conversion Adapter and the Fittings securely with retaining screws and tighten the screws by applying torque within specified limits Loose screws can lead to the dropping of the converter adapter or fittings possibly causing breakage thereof Excessive tightness of the screws can lead to breakage of the screws converter adapter fittings or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof Always check for correct match between MELSEC Q Series and the Conversion Adapter Incorrect match can cause damage to the MELSEC Q Series module A 1 Installation Precautions When installing the converter adapter take care not to get your ha
16. short circuit or malfunction Use care to prevent foreign materials including cuttings and wiring debris from entering the Conversion Adapter or the MELSEC Q Series module These will be cause for fire failure or malfunction Startup and Maintenance Precautions Do not touch live terminals There is a danger of electric shock or malfunction Shut off the external power supply for the system in all phases before cleaning or retightening the terminal screws Failure to do so may result in electric shock or cause the MELSEC Q Series module to fail or malfunction Loose screws can lead to dropping shorting and malfunction Excessive tightness of the screws can lead to breakage of the screws converter adapter fittings or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof Do not modify the Conversion Adapter or take it apart Doing so will cause failure malfunction personal injury or fire The Conversion Adapter comes in a resin case Do not drop the Adapter or give a strong impact to it This will cause damage to the Adapter Disposal Precautions When you dispose of the Products handle them as industrial waste A 2 EMC AND LOW VOLTAGE DIRECTIVES Compliance to the EMC Directive which is one of the EU Directives has been a legal obligation for the products sold in European countries since 1996 as well as the Low Voltage Directive since 1997 Manufacturers who recogniz
17. specification related restrictions Check the specification of the devices to be connected for more details Conversion Adapter MELSEC AnS Noat a MELSEC Q Mass of Conversion model name Series ana og inp Series Adapter g points ERNT ASQT62DA A1S62DA 2 Q62DAN 75 Internal circuit diagram of ERNT ASQT62DA Terminal Signal Terminal Signal number name number name TBI TEST TBI V TB2 HLD CLR TB2 CH1 COM TB3 TEST TB3 T TB4 HLD CLR TB4 Open TBS Open TBS V Q62DAN A1S62DA TB6 Open TB6 CH2 COM terminal block terminal block TB7 V TB7 T aE TBS A Ve TBS Open cA 7521183 TB9 T TB9 Open T8485 Teej es TB10 E TB10 Open Teale TBE HB9 TBI Open TB11 Open rato medre TB12 Open TB12 Open TB12FB73 EE TB13 o V TB13 Open erst rete T4 pO V TB14 Open T510 87 B18 STI BE E TB15 Open E2 TB16 E TB16 24V 24v DC TB17 Opne TB17 24G E gt TB18 Open 24V TB18 FG TB19 Open 24G E gt TB20 Open FG E Q62DAN is not provided with a terminal for Offset Gain setting or Output Hold Clear setting purposes Make Output Hold Clear setting by choosing an appropriate Q62DAN intelligent function modul
18. t after manufacture and shipment from MEE the maximum distribution period shall be six 6 months and the gratis warranty period after manufacturing shall be limited to eighteen 18 months In addition the gratis warranty period for repaired products shall not exceed the gratis warranty period established prior to repair Gratis Warranty Range The gratis warranty range shall be limited to normal use based on the usage conditions methods and environment etc defined by the terms and precautions etc given in the instruction manual user s manual and caution labels on the product Warranty Period after Discontinuation of Production 1 MEE shall offer product repair services fee applied for seven 7 years after production of the product has been discontinued Discontinuation of production shall be reported via distributors 2 Product supply including spare parts is not possible after production has been discontinued Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability Regardless of the gratis warranty period MEE shall not be liable for compensation for damages arising from causes not attributable to MEE opportunity losses or lost profits incurred by the user due to Failures of MEE products damages or secondary damages arising from special circumstances whether foreseen or unforeseen by MEE compensation for accidents compensation for damages to products other than MEE products or compensation for
19. torque listed in the table blow Application of improper tightening torque will cause dropping short circuit failure or malfunction Component attached with screw Range of tightening torque Base Adapter attaching screw M5 2 75 to 3 63N m Q Series module attaching screw M4 1 39 to 1 89N m Mounting bracket securing screw M3 5 0 68 to 0 92N m Conversion Adaptor attaching screw M3 0 43 to 0 57N m MELSEC AnS Series terminal block attaching screw M4 0 78 to 1 18N m 9 6 Dimensional Outline Drawing Unit mm Fitting Terminal block cover y A JO PPS Ola p gt 10 Please confirm the following product warranty details prior to product use is Warranty Range If any fault or defect hereinafter referred to as Failure attributable to Mitsubishi Electric Engineering Company Limited hereinafter referred to as MEE should occur within the gratis warranty period MEE shall repair the product free of charge via the distributor from whom you made your purchase Gratis Warranty Period The gratis warranty period of this product shall be one 1 year from the date of purchase or delivery to the designated place Note tha
20. umption 080A 0 33 A External supply Voltage 24V DC 20 15 power Current 0 15A POINT 1 A1S62DA and Q62DAN differ from each other in the way input output signals X Y and buffer memory addresses are allocated Therefore you need make necessary changes to the sequence program that is used 3 Conversion Adapter MELSEC AnS Number of MELSEC Q Mass of Conversion model name Series analog input Series Adapter g points A1S68DAV 8 Q68DAVN ERNT ASQT68DA 75 A1S68DAI 8 Q68DAIN i Internal circuit diagram of ERNTASOTEEDA r T Q6SDAVN Terminal Signal Terminal Signal Q68DAIN number name number name 1 TBI HLD CLR TBI Jop LV TB2 HLD CLR TB2 COM eiseca TB3 Vail TB3 Vet ECO TB4 41 com TB4 2 com Series MELSEC AnS 7g5 Vali TBS Vile terminal block Series T86 CH2 COM Ta6 CH3 com ma terminal block T57 Vaii TB7 V Taahe TB5 i Tex 81 Tes C43 com Tee com Mer TB4 TBO Veit TBO Veit Teg TBS TB1 I T5817 TB10 H4 com B0 CS com fea TB9 TB11 VIl TB11 Valle ea TB1 TB 15 if rere TBi2_ CH5 com Tez 06 com
21. ution mode value value output Digital input Maximum Digital input Maximum 2000 10V range value resolution value resolution VO characteristics 1000 5v Oto 5V 7 25mV 0 416mV 0 ov Ttosv 914000 a omy 912 12000 f o333mv 1000 5V 10 to 10V 2 5mV_ 16000 to 16000 _0 625mV 2099 10v User range 4000 to 4000 4 75my 12000 to 12000 0 333mv setting Maximum resolution 5mV F Ambient temperature 25 5 C Within 0 1 10mV Overall accuracy 1 0 4100mV Ambient temperature 0 to 55 C Within 0 3 30mV Hea ihe Maximum 4 ms 8 channels 80 ps channel Absolute maximun output n 12V Analog output points 8 channels module 8 channels module Between the output terminal and Photocoupler insulation Photocoupler insulation programmable controller power Insulation on method PPY Between channels Non insulation Non insulation Between external supply power and Transformer insulation analog output No of occupied points 32 points 16 points Connected terminal block 20 points terminal block 18 points terminal block Current consumption 0 65 A 0 38A External supply Voltage E 24V DC 20 15 power Current B 0 2A 1 A1S68DAV and Q68DAVN differ from each other in the way input output signals X Y and buffer memory addresses are allocated Therefore you need make necessary changes to the sequence program that is used POINT 4 Mounting and Installation 4 1 Handling Instructions 1 Before attempting to inst