        Extech FM100 Formaldehyde (CH2O or HCHO) Monitor
         Contents
1.    USER GUIDE    EXT    INSTRUMENTS    Digital Formaldehyde Meter    Model FM100       EXTECH INSTRUMENTS  Introduction    Thank you for selecting the Extech Instruments Model FM100  The FM100 measures  Formaldehyde CH O  HCHO  concentration  Air Temperature  and Relative Humidity  The alarm  feature alerts the user when the Formaldehyde 0 08ppm limit is exceeded     The FM100 can be wall mounted or used as a table top device     This device is shipped fully tested and calibrated and  with proper use  will provide years of  reliable service  Please visit our website  www extech com  for the latest version of this User  Guide  Product Updates  and Customer Care     Features    e Alternately displays Formaldehyde concentration  Air Temperature  and Relative  Humidity at 6 second intervals    e Bright multicolor LED displays green for safe HCHO levels  yellow for caution  and red for  danger    e Alarm display icon and audible beeper alerts user when Formaldehyde concentration  limit of 0 08ppm is exceeded    e Selectable Formaldehyde unit of measure ppm or mg m   e ZERO calibration function   e Manual temperature and Relative Humidity compensation  e Designed with electrochemical CHO  HCHO  sensor   e Low battery indicator    Meter Description    1  Offset adjustment potentiometer    2  Control Button       3  AC Power Adaptor Port                4  LCD Display    5  Multi color LED Indicator    Note  Battery compartment  tilt stand   and wall mount located on rear of EXTECH  m
2.  slotted openings on the meter housing  these are where the sensors are located   Otherwise  accuracy may be compromised        Change Formaldehyde Unit  ppm or mg m        When P75 is shown on the display  press and hold the control button to enter the unit  selection mode  Choose the units  ppm or mg m     by momentarily pressing the control  button  Once the desired units are chosen  press and hold the control button to save the  setting  The LCD display will return to the normal measurement mode     HCHO PPM HCHO PPM HCHO  mg m  mg m  p o OG   gt    gt     Beeper Activate or Inactivate Selection                            When bPrb is shown on the display  press and hold the control button to enter the alarm   beeper  setting mode  Momentarily press the control button to toggle the beeper  condition ON or OFF  Once selected  press and hold the control button to save and return  to the normal mode of operation                     N    HCHO HCHO   HCHO    b  rb     b on  gt  b of                         5 FM100 en GB_v1 6 12 14    EXTECH INSTRUMENTS  Revert to Factory Default Settings    When rF 5  is shown on the LCD display  press and hold the control button to reset the  meter to its default  factory  settings     HCHO    F      Escape Return Function          r  When ESES is shown on the LCD display  press and hold the control button for 3 seconds to  abort the current programming step and return to the normal measurement mode     HCHO    ESO    Maintenance             
3.  temperature unit  Momentarily press the Calibration control button to toggle   C and   F  units  To save setting  press and hold the control button  The meter will return to the  normal mode     HCHO HCHO HCHO  a e i   F    Temperature Compensation Adjustment          When S    3 is shown on the display  press and hold the control button  The factory default     0 0    value will flash  Turn the compensation potentiometer clockwise to increase the  temperature offset or counterclockwise to decrease offset   The range is  5 4  F to  5 4  F     3 0  C to  3 0  C   When done  press and hold the control button to save the setting  The  meter will return to the normal measurement mode and will reflect the offset when  temperature readings are displayed     HCHO UU tho    SEER do                  4 FM100 en GB_v1 6 12 14    EXTECH INSTRUMENTS  Relative Humidity Compensation Adjustment  When 5ErW is shown on the display  press and hold the control button to enter the relative  humidity compensation adjustment mode  Momentarily press the control button to make a  step change in the RH  offset  the range is  9 to  9 RH    When done  press and hold the  control button to save the setting  The meter will return to the normal mode   Warning  While performing the compensation adjustments  do not touch the sensor  as  accuracy may be lost when adjusting the temperature values     Hno acto     Ses Og    Warning  While performing temperature or RH  compensation adjustments do not touch  the
4.  the specified measurement range    E 3  Relative Humidity  RH    readings are outside of the specified measurement range    Specifications   Display Multifunction LCD  Dimensions 48 x 28mm  1 89 x 1 10      Front Panel LED indicator Green for normal  yellow for caution  and red for danger  Formaldehyde CH 0  HCHO  measurement range 0 00 to 5 00ppm  mg m gt    HCHO accuracy  5  of reading  0 03ppm  baseline drift     Accuracy Note  Accuracy meets NIOSH acceptance criterion within   25  of the true value at 95  confidence level    Air Temp  Measurement range 0  C to 50  C  32  F to 122  F    Air Temperature Resolution 0 1  C  0 1  F    Air Temperature Accuracy  1 0  C  1 8  F    Relative Humidity range 20 to 90 RH   RH Resolution 1  RH   Relative Humidity Accuracy  5    Power AAA batteries x 4 pcs or universal AC adaptor  included   Meter dimensions 113 x 108 x 53mm  4 4 x 4 3 x 2 1       Weight 159g  5 6 oz      Copyright O 2014 FLIR Systems  Inc     All rights reserved including the right of reproduction in whole or in part in any form    www extech com    7 FM100 en GB v1 6 12 14    
5. Low Battery Condition and Battery Replacement    When the battery icon      appears on the LCD  the batteries must be replaced  If the meter is  low on battery voltage  erratic or inaccurate readings may result  Never use the meter with the  low battery icon displayed     The battery compartment is on the back of the instrument  Slide the battery compartment cover  off of the meter to access the batteries  Replace the 4 AAA batteries observing proper polarity  and replace the compartment cover before switching the meter ON     Battery Safety Reminders  o Please dispose of batteries responsibly  observe local  state  and national regulations   o Never dispose of batteries in a fire  batteries may explode or leak   o Never mix battery types  install new batteries of the same type   Never dispose of used batteries or rechargeable batteries in household waste     As consumers  users are legally required to take used batteries to appropriate  collection sites  the retail store where the batteries were purchased  or wherever  batteries are sold        Disposal  Do not dispose of this instrument in household waste  The user is  obligated to take end of life devices to a designated collection point for the  disposal of electrical and electronic equipment     6 FM100 en GB_v1 6 12 14    EXTECH INSTRUMENTS    Display Error Codes  The following errors may appear on the display     E 1  HCHO readings are outside of the specified measurement range  E 2  Temperature readings are outside of
6. eter        2 FM100 en GB v1 6 12 14    EXTECH INSTRUMENTS  Operation    Powering the meter    If the meter is supplied without batteries installed  install the supplied batteries in the rear  battery compartment to power the meter  Please observe proper polarity     If the meter is supplied with the batteries installed  and a protective battery strip is installed in  the battery compartment  remove the protective strip to power the meter     Alternatively  plug an AC adaptor into the jack on the side of the meter and then into an AC  power source to power the meter     Normal Operating Mode    When switched ON  the LCD displays  0000  for a period of time  depending on the time that the  meter has been inactive  The meter will then proceed to the normal mode of operation where  the LCD displays the current HCHO level in ppm  the Temperature    C   F   and RH   relative  humidity  alternately at 6 second intervals     Multi Color Status Indicator LED    The Front panel status LED uses a color coding system to inform the user as to the measured  HCHO concentration  Green for Good  Yellow for Hazard  Red for Danger  If the LED fails to  illuminate please return the unit for service     Alarm indication    When the Formaldehyde limit of 0 08ppm is exceeded the meter audibly beeps and flashes an  alarm icon on the LCD  Refer to the CONTROL BUTTON section to learn how to silence the  beeper     Control Button    The Control button located on the left side of the meter is used to c
7. ontrol and program a variety  of meter functions  Press and hold the Control button to enter the function mode  Repeated  presses of the control button cycle through the available parameters  These parameters  in  order  are     e ZERO Calibration   e Temperature Unit selection    C   F    e Temperature compensation  used in conjunction with side potentiometer adjust   e Humidity compensation  used in conjunction with side potentiometer adjust    e Unit of measure change  ppm or mg m       e Alarm Beeper ON OFF   e Factory Default setting reset   e Escape Return  abort operation and return to normal operation     Note  A removable cover protects the offset adjustment and prevents unintentional  adjustment  Remove the protective cover to perform an offset adjustment     3 FM100 en GB_v1 6 12 14    EXTECH INSTRUMENTS  ZERO Calibration  Ensure that calibration is performed in a clean air environment  no VOCs or HCHO gases    Press and hold the control button for 3 seconds  until CAL  appears on the LCD screen    Press and hold the button again to start calibration   Release the control button and wait 300 seconds for the calibration to complete  The meter    will display    END    for 2 seconds when calibration is complete and will then return to the  normal mode of operation          HCHO 77    rai   gt  300   gt  End    A             m             Changing Temperature Units   C   F    When f  F2 is shown on the display  press and hold the control button to display the current 
    