        Elite User Manual
         Contents
1.     Do not use phenolic based products for cleaning     Dry the mattress on a SUNLESS capitalised area    after cleaning     During cleaning procedures  suitable protective clothing  should be worn  Ensure that the mains power supply to    the pump has been disconnected prior to cleaning     Follow the national requirements for the correct disposal    of the pump unit        1  To store the mattress  lay the mattress out flat and upside down   2  Roll from the head end towards the foot end     A NOTE    7  Maintenance    Do not fold  crease or stack the mattresses     Avoid direct sunlight        The entire timer assembly should be replaced every 3 years of service     If a fault occurs please refer to troubleshooting or contact Park House Healthcare     Elite User Manual    8  Troubleshooting    The pump is showing no  indication it is working         Check if the plug is connected to the mains          Check that the hoses are all connected     Check if there is any leakage in the mattress system     Check that the CPR tag is still in place     The low pressure light is  constantly on         Disconnect hoses from pump and check if air is coming  out    G Check that all hoses are connected securely      Check that the CPR is in place    The pump is on but not   Check that there are no obvious leaks in the mattress   inflating the mattress system      Check that the pressure is in the suggested range for  the weight of the patient      Check that there are no kinks in the tu
2.    Park   House       Healthcare    ELITE    PA5550 Mattress Replacement System       User Manual       CONTENTS         On       Introduction    1 1 General Information  1 2 Intended Use    Product Description  Installation    3 1 Unpacking  3 2 Setting Up    Operation  4 1 Transport Mode    4 2 CPR Requirement  4 3 Support Setting Procedure    Cleaning    5 1 Pump Unit  5 2 Mattress    Storage   Maintenance  Troubleshooting  Technical Description  Guarantees and Warranty    10 1 Pump Unit   10 2 Mattress   10 3 Guarantee   10 4 Warranty   10 5 Claims relating to Guarantee and Warranty    O O    NN    IMPORTANT SAFEGUARDS  READ ALL INSTRUCTIONS BEFORE USING    DANGER   To reduce risk of electrocution     Always unplug this product immediately after using    Do not use while bathing    Do not place or store product where it can fall or be pulled into a tub or sink   Do not place in or drop into water or other liquid    Do not reach for a product that has fallen into water  Unplug immediately     MeO Na    WARNING   To reduce risk of burns  electrocution  fire  or injury to persons     This product should never be left unattended when plugged in    Close supervision is necessary when this product is used on or near children    Use this product only for its intended use as described in this manual  Do not use attachments  not recommended by the manufacturer    4  Never operate this product if it has a damaged cord or plug  if it is not working properly  if it  has been dropped 
3.  declination and provide the customer with an estimate on either the repair    or replacement cost     Park House Healthcare reserves the right to alter or amend this document without prior  notice     Elite User Manual    Notes                                                                      New Corporate Headquarters opened in October 2006    The Company    Founded in 1984  Park House Healthcare Ltd is recognised as one of the leading manufacturers of specialist  pressure relieving and pressure reducing equipment in the U K     Park House Healthcare Ltd has an extensive product portfolio and the facility to customise products to suit  customer needs whilst offering solutions in pressure care  postural management and moving and handling     Employing over 100 full time staff at our 60 000 sq  ft state of the art Corporate Headquarters in West Yorkshire   Park House Healthcare are proud to offer in house manufacturing  a full product audit and decontamination  service and a network of distribution centres as part of our continued commitment to Customer Care     24 hour care  365 days a year dedicated internal personnel manage specific regions and divisions ensuring one   on one personal customer service at all times  With distributors in over 25 countries  Park House Healthcare  are a truly international company and we place important emphasis on providing high levels of customer care to  ensure we exceed customer expectations at all times     Additional support nationwid
4. I Equipment    E  bt    BI    SAVE THIS MANUAL FOR REFERENCE    1  Introduction       This manual should be used for initial setup of the system and for reference purposes   1 1 General Information    The Elite is an alternating mattress replacement system suitable for the treatment and  prevention of pressure ulcers     1 2 Intended Use  This product is intended to reduce the incidence of pressure ulcers whilst optimising    patient comfort     A NOTE   Equipment not suitable for use in the presence of a  flammable anaesthetic mixture with air  oxygen or nitrous    oxide     2  Product Description       The Elite Mattress Replacement System provides a cost effective solution for both  the prevention and treatment of pressure ulcers  suitable for patients up to Very High  Risk  Easy to install and operate  the Elite is suitable for both hospital and homecare  environments  The Elite offers a comfortable support surface whose cells gently inflate  and deflate in accordance with established alternating procedures  With an underlayer  of fully encased visco elastic foam for added support  the Elite mattress combines  alternating therapy with optimum user comfort     3  Installation       3 1 Unpacking    The pump unit and mattress are packaged in separate boxes to secure the contents  inside  When unpacking the boxes to remove the pump unit and mattress  check for any  damage which may have occurred during shipping  Please report any damages to Park  House Healthcare and remove 
5. bing running  down the side of the mattress        The system does not appear      Check that there are no kinks in the tubing running  to be alternating down the side of the mattress        The pump is operating    noisily   Make sure the pump is resting against a solid surface                 If your problem cannot be resolved using the above information  please contact Park  House Healthcare     WE Flite User Manual    9  Technical Description              PA5550       Product Code       Specification          Power Supply     refer to rating label on the product  AC 230V  50Hz                           Fuse Rating T1A   Dimension  L x W x H  30 x 19 x 9 5  cm    Weight 2kg   Environment Temperature Operation   40  C to 70  C  Storage   40  C to 70  C  Shipping   40  C to 70  C              10  to 100  non condensing  10  to 100  non condensing  10  to 100  non condensing    Humidity Operation   Storage     Shipping                    Class II       Classification       Mattress Specification         Dimension  L x W x H   Weight    200 x 89 x 17 5  cm   3kg   30   80 mmHg   159 kg or 25 stones          Pressure Range                   Maximum Patient Weight    Contact the distributor or EU representative for further technical documents     A  NOTE   1  The specifications also apply to those areas  operating with the same power supply   2  The manufacturer reserves the right to modify the  specification without notice   3  The earth terminal is functional earth  not a prot
6. deflation  of the mattress is required  disconnect the two hoses from the pump     Elite User Manual    4 3 Support Setting Procedure    It is important to follow the correct support setting procedure so to ensure the patient  recieves adequate support  maximum pressure relief and comfort  Failure to do this  could result in the patient being put at risk    1  Lie the patient on the mattress    2  Reset the pressure dial on the pump according to the patient   s weight  Ensure the  correct pressure setting has been selected  Yellow weight settings indicate where  to position the dial if the patient is lying down  white weight settings indicate where  to position the dial if the patient is sitting up    NB   for pump models without weights indicated on the dial  use the weight guide table below    3  Maximum patient weight limit 159kgs  350lbs   25 stones     Minimum patient weight limit 31kgs  7Olbs   5 stones   For patients weighing 31 kgs to 60 kgs set turn the pressure dial to 60 kgs or below                    Pressure Range Dial Weight  kg  Weight  Ib  Weight  st  amp  Ib   Soft 31   50 kg 70   110 Ib 5 st 7 st 12 Ib   Tree eta 51 75 kg 112   165 Ib 8 st  11 st 11 Ib   ai Sa 76   100 kg 168 220lb   12st 15st10lb  Firm 100   159 kg 220 350lb   15 st10 lb   25 st                   NB   The above is a guide only and the dial can be adjusted according to the individuals    comfort    requirements     5  Cleaning       The following guidelines are suggested by Park House Healt
7. e is available through our service centres situation strategically around the country   Park House Healthcare Ltd is a respected member of the British Healthcare Trade Association and has BS EN    ISO 9001 and EN 46002 accreditation which is the specific quality standard for Medical Devices  All products are  CE marked in accordance with the European Directive 93 42 EEC   ty    ce   Sj  Registered Healthcare                      ISO Certificate No  8019 Park House Healthcare Ltd  CE Certificate No  CA001810 Whitehall 26 Business Park   Master Indemnity Assurance No  IFA 2433 0451 CCI 1 Heathfield Lane  Birkenshaw   West Yorkshire  BD11 2HW  UK    Due to its policy of continued development and 0845 0600 333  improvement  Park House Healthcare Ltd 0845 0600 334  reserves the right to amend any details sales parkhouse he com  and specifications without notice   44  0 1274 475000   44  0 1274 475046       Copyright Park House Healthcare Ltd  2012 1 international  parkhouse he com    www parkhouse he com    UM PA5550 15FEB2012 REV3    
8. ective    earth     Elite User Manual D    10  Guarantees and Warranty       10 1 Pump Unit  All new pumps have a guarantee for a period of 2 years following the date of dispatch   10 2 Mattress    All new mattresses have a guarantee for a period of 2 years following the date of  dispatch     10 3 Guarantee    Park House Healthcare guarantees to repair or place any equipment issued to its  customers  which is found to be faulty during the relevant guarantee or warranty period   The Company   s guarantees are subject to following conditions     a  That the equipment has been used for the purpose for which it was intended   b  That the usage has been on a    fair wear and tear    basis    c  That the Company   s cleaning   disinfection guidelines have been followed    d  That the Company   s maintenance guidelines have been followed    e  That maintenance has been carried out by a Park House approved engineer     10 4 Warranty    Extended warranties can be purchased from Park House Healthcare  for more  information contact Customer Services on 0845 0600 333     10 5 Claims relating to Guarantee and Warranty    In the event of a fault being discovered within the warranty period  the customer must  notify Park House Healthcare at the earliest opportunity     If upon inspection  Park House Healthcare accepts liability then the equipment shall be  repaired or replaced immediately     If Park House Healthcare does not accept liability it shall inform the customer of its  reasons for
9. hcare Ltd as being suitable  infection control procedures  Further information is available upon request     5 1 Pump Unit    It is important to follow the cleaning procedures for single patient use  General cleaning  may be affected by using a cloth dampened with a mild detergent and water solution   This approach may be followed either by wiping with a sodium hypochlorite solution to  a dilution of 1000 ppm or by using an alcoholic wipe     Wipe the pump unit with a damp cloth and a mild detergent  and keep it away from  dust  If another detergent is used  choose one that will have no chemical effects on the  surface of the plastic case of the pump unit   A CAUTION   Do not immerse or soak pump unit   Do not use hyper carbonate or phenol based cleaning  solutions     Do not use any abrasive compounds or cleaning pads     WS Flite User Manual    5 2 Mattress    During general use the mattress and tube set may be cleaned by using a mild detergent  solution  Where appropriate mattress covers may be completely removed for laundering  or sterilisation  Whenever there is staining or body fluids on the mattress  including the  cells and tubing  then a sodium hypochlorite solution to a dilution of 1000 ppm should  be used following thorough cleansing with soap and water     All mattress covers may be laundered as follows     Pre Wash 80  C   15 minutes  Main Wash 80  C   15 minutes  Followed by cold rinses and extraction    A CAUTION  A CAUTION  A CAUTION    A CAUTION    6  Storage
10. or damaged  or dropping in water  return the product to a service centre for  examination and repair     oN      5  Keep the cord away from heated surfaces    6  Never block the air opening of this product or place it on a soft surface  such as a bed or  couch  where their openings may be blocked  Keep the air opening free of lint  hair  and other  similar particles    Ds Never drop or insert any object into any opening or hose    8    Connect this product to a properly grounded outlet only  See grounding instructions     NOTE  CAUTION AND WARNING STATEMENTS    NOTE   Indicates some tips    CAUTION   Indicates correct operating or maintenance procedures in order  to prevent damage to or destruction of the equipment or other  property    WARNING   Calls attention to a potential danger that requires correct    procedures or practices in order to prevent personal injury     SYMBOLS       BF    symbol  indicates this product is according to the degree or  protecting against electric shock for type BF equipment     Attention  should read the instructions     Grounding terminal  for 230V system     Disposal of Electrical  amp  Electronic Equipment  WEEE     This product should be handed over to an applicable collection  point for the recycling of electrical and electronic equipment  For  more detailed information about recycling of this product  please  contact your local city office  household waste disposal service  or the retail store where you purchased this product     Class I
11. the system from use     Elite User Manual    3 2 Setting Up   1  Place the pump at the foot end of the bed    2  Remove the existing mattress and place the Elite system directly onto the bed  frame with the cell or vapour cover uppermost  The inflation tubes should be at the    foot end of the bed     A NOTE i The Elite pump must only be used with the    Elite mattress or seat     3  Connect the tubes leading from the mattress to the outlet ports  Inflation tubes  should be at the foot end of the bed on the pump     4  Refer to the comfort control setting and adjust the dial according to the patient   s  weight   see the patient weight guide  section 4 3     5  Connect the pump to the mains power supply and switch on at the pump  At this  stage both the mains power and low pressure indicators will illuminate     6  Cover the support surface with a loosely fitting sheet     7  When the low pressure indicator has extinguished  patient may be placed on the  support surface and further bedding can be added     8  Test the low pressure alarm by pushing the button on the side of the pump and  disconnecting the hoses     4  Operation       A NOTE   Always read the operating instructions before use   4 1 Transport Mode    If required  disconnect the hoses from the pump and join together  The system will then  equalise and retain mattress pressure once the pump has been shut off     4 2 CPR Requirement    In the event of an emergency pull the CPR tag to deflate the mattress  If rapid 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung NX3000 Hướng dẫn sử dụng  "service manual"  Wayne-Dalton 347610 Garage Door Opener User Manual  TW - Wiener lab.  KEY CUTTING MACHINE Operating manual  IP Door Phone IP39-4x User`s Manual  KN 6400-JLMS  PSI Graphic Transport Framework User Manual  Guia del Usuario Operación Access    Copyright © All rights reserved. 