Home
ELATION ELAR QUAD BAR - USER MANUAL 2.0
Contents
1. ETATION ELAR QUAD BAR User Manual 2 0 22 www elationlighting com 2 ELAR QUAD BAR User Manual 2 0 www elationlighting com CONTENTS General Information 4 Safety Instructions 6 General Guidelines 7 Features 8 Fixture Overview 9 Mounting and Installation 10 Understanding DMX 13 Fixture Menu 18 DMX Channel Values 34 Cleaning and Maintenance 36 Photometric Data 37 Dimensional Drawings 37 Circuit Schematic 38 Warranty 39 Technical Specifications 40 Optional Accessories 41 3 ELAR QUAD BAR User Manual 2 0 www elationlighting com 1 GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable lighting fixtures on the market today The ELAR QUAD BAR has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance IP65 RATED An IP rated lighting fixture is one which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress entry of external foreign objects such as dust and water The International Protection IP rating system is commonly expressed a
2. 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Initial Status is displayed and tap ENTER 3 Tap UP DOWN to select desired function Strobe Dimmer Chase Effect Chase Speed Red 1 16 Green 1 16 Blue 1 16 White 1 16 Color Temp Color Mode and tap ENTER to confirm selection 4 Tap UP to select desired position 0 255 and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu 26 ELAR QUAD BAR User Manual 2 0 www elationlighting com PERSONALITY Reset Default Restore factory settings function ON or OFF the default is OFF 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Reset Default is displayed and tap ENTER 3 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection EFFECT ADJUST Test Channel Test each DMX function 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Effect Adjust is highlighted and tap ENTER 2 Tap UP DOWN until Test Channel is displayed and tap ENTER 3 Tap UP DOWN to select desired function Strobe Dimmer Chase Effect Chase Speed Red 1 16 Green 1 16 Blue 1 16 White 1 16 Color Temp Co
3. The DMX address is set electronically using the controls on the LCD menu DATA CABLE DMX Cable REQUIREMENTS For DMX and Master Slave Operation Your fixture and your DMX controller require a standard 3 pin or 5 pin XLR connector for data input and data output see figure below If you are making your own cables be sure to use two conductor shielded digital DMX cable rated at 120 ohms this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers Your cables should be made with a male and female XLR connector on either end of the cable Also remember that a DMX line must be daisy chained and cannot be split unless using an approved DMX splitter such as the Elation Opto Branch 4 or DMX Branch 4 13 ELAR QUAD BAR User Manual 2 0 www elationlighting com DMX Output DMX Input DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket 5 Pin XLR Socket 5 Pin XLR Socket 1 Ground 1 Ground 2 Data 2 Data e 3 Data 3 Data 4 Open 5 Open Be sure to follow the above figure when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR outer casing Grounding the shield could cause a short circuit and erratic behavior DMX 512 CONTROLLER CONNECTION Connect the provided XLR cable to the fe
4. Chase Speed Red 1 16 Green 1 16 Blue 1 16 White 1 16 Color Temp Color Mode Fade Time Secne Time Input By Out and tap ENTER to confirm selection 5 Tap UP DOWN to select desired position 0 255 and tap ENTER to confirm selection For Secne Time tap UP DOWN to select the desired time 00 2s 99 9s and tap ENTER to confirm selection 6 MODE ESC to return to the main menu EDIT PROGRAM Record Controller The moving head features an integrated DMX recorder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head EDIT PROGRAM Record Controller Working With Built In Program A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Progra
5. suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times e Never look directly into the light source of this fixture You risk injury to your retina which may induce blindness Do not attempt to operate this fixture if the power cord has become damaged or frayed Be sure the power cord is never crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating This device falls under protection class 1 therefore it is essential that this device be grounded properly Only qualified personnel should perform all electrical connections Be sure the available voltage matches the voltage requirements of this device e Always disconnect fixture from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end Never pull out the plug by tugging the wire portion of the cord 6 ELAR QUAD BAR User Manual 2 0 www elationlighting com 3 GENERAL GUIDELINES NEVER OPEN THIS FIXTURE WHILE IN USE During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This fixture is a professional lighting effect designed for use on stage in nightclubs the
6. surface weekly to avoid dust accumulation Never use alcohol or solvents MAINTENANCE Regular inspections are recommended to insure proper function and an extended life There are no user serviceable parts inside this fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections Adetailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Besure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person s Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 36 ELAR QUAD BAR User Manual 2 0 www elationlighting com 11 PHOTOMETRIC DATA Beam angle 11 5 ense LOX Red leds 1810 461 220 Green leds 3220 244 370 1 2 3 Distance m 0 2 0 4
7. 0 6 11 5 Diameter m 0 37 0 74 111 2 Diameter m Please Note Specifications and improvements the design of this unit and this manual subject to change without prior written notice 37 ELAR QUAD BAR User Manual 2 0 EraTiow 22 www elationlighting com 13 CIRCUIT SCHEMATIC c usse POWER SUPPLY 38 ELAR QUAD BAR User Manual 2 0 22 www elationlighting com 14 2 YEAR LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional amp products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional amp will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are
8. 0 Black 255 100 Blue U 0 255 White 0 Black 255 100 White 34 ELAR QUAD BAR User Manual 2 0 www elationlighting com ELATION ELAR QUAD BAR ver 1 0 DMX Channel Functions Values Function SHUTTER STROBE All LEDs OFF All LEDs ON Strobe Effect SLOW to FAST All LEDs ON Pulse Effect In Sequences All LEDs ON Random Strobe Effect SLOW to FAST All LEDs ON DIMMER INTENSITY Intensity O to 10096 CHASE MACROS ALL LEDs OFF Chase Macro 1 Chase Macro 2 Chase Macro 3 Chase Macro 4 Chase Macro 5 Chase Macro 6 Chase Macro 7 Chase Macro 8 CHASE SPEED FAST to SLOW COLOR TEMPERATURE ALL LEDs OFF White 2700k White 3200k White 4300k White 5600k White 6500k White 8000k Store White Balance Enabled COLOR MODE Whi Whi Whi e Balance Disabled e Balance Disabled Balance Disabled White Balance Disabled White Balance Disabled Store a New White Balance 35 ELAR QUAD BAR User Manual 2 0 PROFESSIONAL Mode Channel 0 31 32 63 64 95 96 127 128 159 160 191 192 223 224 255 0 255 0 10 0 255 0 31 32 63 64 95 96 127 128 159 220 230 www elationlighting com 10 CLEANING AND MAINTENANCE CAUTION Disconnect from mains before starting maintenance operation CLEANING Frequent cleaning is recommended to insure proper function and an extended life Clean LED lens
9. 3 Tap UP DOWN until RDM PID is displayed and tap ENTER 4 MODE ESC to return to the main menu 24 ELAR QUAD BAR User Manual 2 0 www elationlighting com PERSONALITY Display Setting Shutoff Time Shut off the Control Panel display after 02 to 60 minutes default is 05 minutes 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER Tap UP DOWN until Display Setting is displayed and tap ENTER Tap UP DOWN until Shutoff Time is displayed and tap ENTER Tap UP DOWN to select time 02 60 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 8 5 PERSONALITY Display Setting Display Reverse Rotate Flip the Control Panel display by 180 default is OFF 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Display Setting is displayed and tap ENTER 3 Tap UP DOWN until Display Reverse is displayed and tap ENTER 4 Tap UP DOWN to select desired mode or OFF and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu PERSONALITY Display Setting Key Lock Lock the Control Panel buttons automatically after exiting main menu for 15 seconds Unlock by keeping the MODE ESC button pressed for 3 seconds Default is OFF 1 Tap MODE ESC to access the main menu tap
10. DOWN until Software Version is displayed and tap ENTER 3 The display will show VX X software version 4 Tap MODE ESC to return to the main menu PERSONALITY Status Settings Address Via DMX Adjust the desired DMX address via an external controller default is ON Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 1 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Address Via DMX is displayed and tap ENTER 5 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings No DMX Status Fixture runs in Auto Run if no DMX signal is detected Options include Hold Close Shutter Music Control Auto Program default is Hold Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 UP DOWN until Status Settings is displayed tap ENTER 3 Tap UP DOWN until No DMX Status is displayed and tap ENTER 4 Tap UP DOWN to select desired mode Hold Close Shutter Music Control Auto Program and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 23 ELAR QUAD BAR User Manual 2 0 www elationlighting com PERSONALITY Service Setting Password The Password is 050 1 Tap MODE ESC to access the main
11. EM MENU The ELAR QUAD BAR comes with an easy to navigate system menu The next section will detail the functions of each command in the system menu LCD CONTROL PANEL The control panel see image below located on back of the fixture allows you to access the main menu and make all necessary adjustments to the ELAR QUAD BAR During normal operation tapping the MODE ESC button once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting tap the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Tapping the ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by tapping the MODE ESC button Era TIO NP ELAR QUAD BAR 2100 240 50 80Hz Power consumption 70W f CE Y 4 4 1 5 17 ELAR QUAD BAR User Manual 2 0 www elationlighting com DMX Address Setting DMX Value Display Slave Setting Auto Program Power On Running Time Fixture Running Time Fixture Last Times Clear Timer Password 038 Clear Fixture Last time Temperature In The Head Software Version Of Each IC Address Via DMX Auto Run If No DMX Service Password 050 RDM PID Code Display Shut Off Time Display Reverse 180 Key Lock Display Flashes If No DMX Temperature sw
12. N LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN buttons until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Current Time is displayed tap ENTER and XXXXXh Hours is displayed 4 MODE ESC to return to the main menu INFORMATION Time Information Total Run Time Display the total running time of the fixture 1 Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Total Run Time is displayed tap ENTER and XXXXXh Hours is displayed 4 MODE ESC to return to the main menu INFORMATION Time Information Last Run Time Display last the running time of the lamp 1 Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Last Run Time is displayed tap ENTER and XXXXXh Hours is displayed 4 Tap MODE ESC to return to the main menu 21 ELAR QUAD BAR User Manual 2 0 www elationlighting com INFORMATION Time Information Timer Password Display the timer password 038 Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER Tap UP DOWN until Time Information is d
13. Patterns On Off Cycling Control and Dimming OPTICAL 11 5 Beam Angle 21 Field Angle COLOR MIXING RGBW Additive Color Mixing 16 7 Million Color Possibilities STROBE DIMMER Strobe effect with variable speed 1 18 flashes per second 0 100 Dimmer DMX CHANELS 4 5 8 10 16 DMX DRIVE USITT DMX 512 3 pin IP65 rated XLR Pin 3 Pin 2 Ground Piin 1 Starting DMX 001 SIZE and WEIGHT 19 7 L x 5 9 W x 6 1 H 500mm L x 150mm W x 156mm H Weight net 12 lbs 5 4 kgs RATINGS IP Rating P65 Maximum Ambient 45 C 113 F Temp Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 40 ELAR QUAD BAR User Manual 2 0 www elationlighting com 16 OPTIONAL ACCESSORIES ORDER CODE ITEM DESCRIPTION ELARQUAD GFH Gel Frame for ELAR QUAD Series 41 ELAR QUAD BAR User Manual 2 0 Elation Professional USA 6122 5 Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu
14. Programs To Be Run Testing Program Program In Loop Save And Exit Save And Automatically Return Manual Scenes Edit Automatic Scenes Recorder 4CH Mode 5CH Mode 8CH Mode 10CH Mode 16CH Mode User Mode A User Mode B User Mode C Max Channel Strobe Dimmer Chase Effect Chase Speed Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Temp Color Mode Auto Pro Part1 Program 1 10 Program 1 Auto Pro Part2 Program 1 10 Program 2 Auto Pro Part3 Program 1 10 Program 3 Program 1 Pro Test Program 10 Step 01 Step 64 Strobe Dimmer Chase Effect Chase Speed Red 1 4 Scene 001 Green 1 4 Blue 1 4 Scene 250 White 1 4 Color Temp Color Mode Fade Time Scene Time Input By Out XX XX 19 ELAR QUAD BAR User Manual 2 0 User Mode Edit User Mode A Edit User Mode B Edit User Mode C Select Program Edit Program Edit Scenes Record Controller PROFESSIONAL USER MODE SETTING EDIT PROGRAM Default Settings Shaded www elationlighting com FUNCTION Set DMX Address Adjust the desired DMX address via the Control Panel 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap the UP DOWN until Set DMX Address is displayed and tap ENTER 3 Current DMX address is displayed 001 503 tap the UP DOWN to select desired DMX address 001 503 and ENTER to confirm selection 4 Tap MODE ESC to return to the mai
15. UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Display Setting is displayed and tap ENTER 3 Tap UP DOWN until Key Lock is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu 25 ELAR QUAD BAR User Manual 2 0 www elationlighting com PERSONALITY Display Setting Disp Flash Control Panel display will flash if no DMX is signal is detected default is OFF 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Display Setting is displayed and tap ENTER 3 Tap UP DOWN until Disp Flash is displayed and tap ENTER 4 Tap UP DOWN to select desired mode or and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu PERSONALITY Temperature C F Display the temperature in Celsius or Fahrenheit default is Fahrenheit 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Temperature C F is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Celsius or Fahrenheit and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu PERSONALITY Initial Status Display the initial effect position for DMX functions
16. atres etc Do not attempt installation and or operation without proper knowledge of how to do so Do not permit operation by persons who are not qualified for operating this type of theatrical fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come Do not shake fixture avoid brute force when installing and or operating the device Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the base of the fixture Please use the original packaging and materials to transport the fixture in for service 7 ELAR QUAD BAR User Manual 2 0 www elationlighting com 4 FEATURES 4x 10W Cree Quad LEDs 100 000 Hours Rated LED Life May vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming P65 Rated Die Cast Aluminium Body e USITT DMX 512 with 4 5 8 10 and 16 DMX Channel Operation Strobe Effect with 1 18 flashes per second e 0 100 Dimming and Blackout for all LEDs Excellent Color Mixing and Rainbow Effect e Single Pixel Control Mode e Flicker Free Operation for TV and Film Built In Co
17. com EDIT PROGRAM Record Controller Working With Built In Program continued The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture Part 1 ese set om m H Part 2 m D Part 3 33 ELAR QUAD BAR User Manual 2 0 www elationlighting com PROFESSIONAL 9 DMX CHANNEL FUNCTIONS AND VALUES ELATION ELAR QUAD BAR ver 1 0 DMX Channel Functions Values Mode Channel Function ow pom ELE 20 Red 0 Black 255 100 Red Green 0 Black 255 100 Green Blue 0 Black 255 100 Blue ajae White x 0 Black 255 100 White Hmm 0 255 Red 1 0 Black 255 100 Red C GEE 0 255 Green 0 Black 255 100 Green CO Blue 0 Black 255 100 Blue 0 LED 1 White 0 Black 255 100 White Red 0 Black 255 100 Red ERN LED 2 Green 0 Black 255 100 Green EmA 0 255 Blue 0 Black 255 100 Blue WHITE LED 2 0 255 White 0 Black 255 100 White RED LED 3 Red 0 Black 255 100 Red GREEN LED 3 Green 0 Black 255 100 Green BLUE LED 3 Blue 0 Black 255 100 Blue mE LED 3 White 0 Black 255 100 White E Red 0 Black 255 100 Red GREEN LED 4 Green 0 Black 255 100 Green BLUE LED 4 0 255 Blue
18. contacting customer support at 323 582 3322 IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 5 ELAR QUAD BAR User Manual 2 0 www elationlighting com 2 SAFETY INSTRUCTIONS The ELAR QUAD BAR is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual e For stage operation follow the Mounting and Installation guide described in Chapter 6 of this manual Operating the fixture without suited safety aids such as safety cables and or clamps can increase the risk of damage and or personal injury Installation should only be performed by qualified and certified personnel When mounting this fixture use only the original rigging parts included with this fixture Any structural modification will void the original manufactures warranty and may increase the risk of damage and or personal injury Those
19. d PIN 3 DMX of the last fixture 1200 lil PIN2 5 Pin XLR DMX CONNECTORS Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The following chart details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conversion 3 Pin XLR Female 5 XLR Male In Data True signal Pin 3 15 ELAR QUAD BAR User Manual 2 0 www elationlighting com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture You can set the same starting address for all fixtures or a group of fixtures or set different address for each individual fixture Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the f
20. isplayed and tap ENTER Tap UP DOWN until Timer Password is displayed and tap ENTER Tap UP DOWN to select 3 digit password and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 1 x I INFORMATION Time Information Clear Last Run Clear the last run time of the fixture default is OFF Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 10 2 Tap UP DOWN until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Clear Last Run is displayed and tap ENTER to Clear Last Run time NOTE A correct password must be entered in the Timer Password menu in order to clear last run time MODE ESC to return to the main menu INFORMATION Temperature Information Head Temperature Display the temperature of the fixture default is Celsius MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 1 2 Tap UP DOWN buttons until Temperature Info is displayed and tap ENTER 3 Tap ENTER and XXX degrees C F is displayed 4 Tap MODE ESC to return to the main menu 22 ELAR QUAD BAR User Manual 2 0 www elationlighting com INFORMATION Software Version Display the software version of the fixture Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 1 2 Tap UP
21. itch Between C or F Initial Effect Position Restore Factory Settings Test Function Fine Adjustment Of The Functions 001 503 ALL 1 Slave2 Slave3 Master Alone Current Time XXXX Hours Total Run Time XXXX Hours Last Run Time XXXX Hours Timer Password Password XXX Clear Last Run ON OFF Head Temperature V2 0 Address Via DMX ON OFF No DMX Status Close Hold Auto Music Password Password XXX RDM PID XXXXXX Shutoff Time 02 60m 05m Flip Display ON OFF Key Lock ON OFF Disp Flash ON OFF Fahrenheit Celsius Strobe Dimmer Chase Effect Chase Speed Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Temp Color Mode ON OFF Strobe Dimmer Chase Effect Chase Speed Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Temp Color Mode Strobe Dimmer Chase Effect Chase Speed Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Temp Color Mode 18 ELAR QUAD BAR User Manual 2 0 Set DMX Address DMX Value Slave Mode Auto Program Time Information Temperature Info Software Version Status Settings Service Setting Display Setting Temperature C F Initial Status Reset Default Test Channel Manual Control FUNCTION INFORMATION PERSONALITY EFFECT ADJUST Default Settings Shaded www elationlighting com Select DMX amp User Modes Preset User Modes Select
22. ixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the ELAR QUAD BAR when in 16 channel mode default can also be set to 4 5 8 10 or 16 you should set the starting DMX address of the first unit to 1 the second unit to 17 1 16 the third unit to 33 17 16 the fourth unit to 49 33 16 and so on Note During start up the ELAR QUAD BAR will automatically detect whether a DMX data signal is being received or not If DMX data signal is being received the display will show XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following The 3 PIN or 5 PIN XLR input plug cable with DMX signal from controller is not connected or is not inserted completely into the DMX input jack of the fixture The DMX controller is switched off or defective The DMX cable or connector is defective A DMX terminator has been inserted into the last fixture in your DMX chain 16 ELAR QUAD BAR User Manual 2 0 www elationlighting com 8 FIXTURE MENU ON BOARD SYST
23. jack 13 Power Out Power connection to daisy chain to another unit 9 ELAR QUAD BAR User Manual 2 0 www elationlighting com 6 MOUNTING AND INSTALLATION CAUTION Please consider the GB7000 15 EN60598 2 17 and the other respective national norms during the installation The installation must only be carried out by a qualified person CAUTION The electric connection must only becarried out by a qualified electrician CAUTIONS The recommended temperature for this fixture is 13 F to 113 F 25 C to 45 C Do not use the fixture under or above this temperature For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 150 Ibs 680 kgs Includes Omega Bracket Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture 10 ELAR QUAD BAR User Manual 2 0 www elationlighting com MOUNTING POINTS Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation
24. layed and tap ENTER 1 3 Tap UP DOWN to select desired mode 4CH Mode 5CH Mode 8CH Mode 10CH Mode 16CH Mode User Mode User Mode B User Mode and tap ENTER to confirm selection MODE ESC to return to the main menu USER MODE SETTING Edit User Mode A B 6 Adjust the rest user defined channel order Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until User Mode 56 is highlighted and tap ENTER Tap UP DOWN to select desired user Edit User Mode A Edit User Mode B Edit User Mode C is displayed and tap ENTER Tap UP DOWN to select desired mode Max Channel Strobe Dimmer Chase Effect Chase Speed Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Temp Color Mode and tap ENTER to confirm selection Tap UP DOWN to select desired channel and tap ENTER to confirm selection 1 5 Tap MODE ESC to return to the main menu 28 ELAR QUAD BAR User Manual 2 0 www elationlighting com EDIT PROGRAM Select Program Select Auto Programs default for Auto Pro Part1 is Program 1 for Auto Pro Part2 is Program 2 and for Auto Pro Part3 is Program 3 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Edit Program is highlighted and tap ENTER Tap UP DOWN until Select Program is displayed and tap ENTER Tap UP DOWN to select desi
25. lor Macros Auto amp Manual Control Full Color LCD Menu Control Display And Touch Panel Reversible Control Display Option 180 Flip Power In Out Linkable Holds Last State When Power Off e Software Upload by Optional Accessory via DMX line 8 ELAR QUAD BAR User Manual 2 0 www elationlighting com 5 FIXTURE OVERVIEW LED Array Mounting Ears Omega Bracket Power IN 2 3 4 3 Pin DMX IN 1 42 5 LCD Menu Control Display F 6 MODE ESC Button 7 ENTER Button 8 LEFT Button 9 DOWN Button 10 RIGHT Button 11 UP Button 12 3 Pin DMX OUT 13 Power OUT LED Array Group of 4 LEDs Mounting Ears Omega Bracket Used to mount fixture Power In Power connection powerCON to power source 3 Pin DMX In Accepts incoming DMX signal via a male 3 pin XLR jack LCD Menu Control Display Full color LCD animated menu display MODE ESC Button Used to access the menu functions and exit the current command ENTER Button Used to enter into or lock a certain menu function LEFT Button Used to toggle through the menu display DOWN Button Used to toggle down or back through the menu functions and settings 10 RIGHT Button Used to toggle through the menu display 11 UP Button Used to toggle forward through the menu functions and settings 12 3 Pin DMX Out Used to send incoming DMX signal to the next fixture the DMX chain via a female 3 pin XLR
26. lor Mode and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu EFFECT ADJUST Manual Control Adjust the lamp more easily All effects will be canceled the shutter opens and the dimmer intensity will be set to 100 With the individual functions you can focus the light on a flat surface wall and perform the fine lamp adjustment 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Effect Adjust is highlighted and tap ENTER 2 Tap UP DOWN until Manual Control is displayed and tap ENTER 3 Tap UP DOWN to select desired function Strobe Dimmer Chase Effect Chase Speed Red 1 16 Green 1 16 Blue 1 16 White 1 16 Color Temp Color Mode and tap ENTER to confirm selection 4 Tap UP to select desired value 0 255 and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu 27 ELAR QUAD BAR User Manual 2 0 www elationlighting com USER MODE SETTING Select different channels list by different sequence For example after the user enter this manual if select Auto Program CH 22 means in this User s mode the Dimmer is in Channel 16 USER MODE SETTING User Mode Create user defined channel orders the default is 4CH Mode Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until User Mode Set is highlighted and tap ENTER Tap UP DOWN until User Mode is disp
27. m Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 30 ELAR QUAD BAR User Manual 2 0 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued To start an Auto Program proceed as follows 1 Slave Setting Select Function Mode by turning on the encoder Press the ENTER button to confirm e Select Set to Slave by turning the encoder Press the ENTER button to confirm Turn the encoder to select Slave 1 Slave 2 or Slave 3 Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 2 Automatic Program Run Select Function Mode by turning on the encoder Press the ENTER button to confirm Select Auto Program by turning on the encoder Press the ENTER button to confirm Turn the encoder to select Master or Alone The selection Alone means Stand Alone mode and Master that the device is defined as master Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 3 Program selection for Auto Pro Part Select Edit Program by turning the encoder Press the ENTER button to confirm e Select Select Programs by turning the encoder Press the ENTER button to confirm e Turn the encoder to select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and thus select which Slave progra
28. m is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 31 ELAR QUAD BAR User Manual 2 0 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued 4 Program Selection for Edit Program e Select Edit Program by turning the encoder Press the ENTER button to confirm Select Edit Program by turning the encoder Press the ENTER button to confirm Turn the encoder to select the desired program With this function you can edit specific scenes into a specific program Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 5 Automatic Scene Recording Select Edit Program by turning the encoder Press the ENTER button to confirm e Select Edit Scenes by turning the encoder Turn the encoder to select the desired scene numbers You can program a maximum number of 250 scenes Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 32 ELAR QUAD BAR User Manual 2 0 www elationlighting
29. male 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the ELAR QUAD BAR Please refer to the diagram below You can chain multiple panels together through serial linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4 or DMX Branch 4 DMX512 is 120 Ohms DMXc controller Address 1 Address 5 Address 9 DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a ine terminator Elation part DMX T PACK will decrease the possibilities of erratic behavior 14 ELAR QUAD BAR User Manual 2 0 www elationlighting com Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX an
30. material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in any mounting position hanging upside down side mounted or on any flat level surface and will remain steady no matter the angle of the fixture head e Be sure the fixture is kept at least 0 5m 1 5 feet away from any flammable materials decoration ES SSE WIT 246 2 25 FV Z ant 0 O 0 O S SZ 6 af AS ON d Sv ci XY MIC 2 ZS SS gt SAS 4 af Se oZ Sa SZ VS S35 2 EN no ZA SL 22 NN A e O O O VS 5 E a 1 ELAR QUAD BAR User Manual 2 0 www elationlighting com 1 Omega Bracket amp 8 Screws included 2 Clamp optional 3 Safety Cable included INSTALLATION VIA OMEGA BRACKET e Attach the included Omega Bracket to the fixture using included 8 small screws Attach clamp to center 13 hole the Omega Bracket e Pull the included Safety Cable through the hole on the side of the base and over the trussing system or a safe installation This step is a very important to ensure the fixture will not drop if the clamp fails 12 ELAR QUAD BAR User Manual 2 0 www elationligh
31. menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER Tap UP DOWN until Service Setting is displayed and tap ENTER Tap UP DOWN until Password is displayed and tap ENTER Tap UP DOWN to select 3 digit password and tap ENTER to confirm selection Tap MODE ESC to return to the main menu x IS PERSONALITY Service Setting RDM PID With this function you can call up various submenus via RDM This device is RDM ready RDM stands for remote device management and makes remote control of devices connected to the DMX bus ANSI E1 20 2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol Manual settings like adjusting the DMX starting address are no longer needed This is especially useful when the fixture is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX line The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices If DMX splitters are used and RDM control is to be used these splitters must support RDM The number and type of RDM parameters depend on the RDM controller being used NOTE A correct password must be entered in the Service Setting menu in order to access the RDM PID menu 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Service Setting is displayed and tap ENTER
32. n menu FUNCTION DMX Value Display the DMX 512 value of each channel 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until DMX Value is displayed and tap ENTER 3 Tap UP DOWN to select desired DMX Value and ENTER to confirm selection 4 Tap MODE ESC to return the main menu FUNCTION Slave Mode Define the fixture as a slave 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until Slave Mode is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Slave1 Slave2 Slave3 and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu FUNCTION Auto Program Define the fixture mode Master or Alone for running Auto Programs Select the desired internal programs under Select Program set the number of steps under Edit Program and edit the individual scenes under Edit Scenes 1 MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until Auto Program is displayed and tap ENTER 3 UP DOWN to select desired mode Alone and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu 20 ELAR QUAD BAR User Manual 2 0 www elationlighting com INFORMATION Time Information Current Time Display the run time of the fixture from last power ON The counter is reset after each time the device is powered OFF 1 Tap MODE ESC to access main menu tap UP DOW
33. n to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professional amp in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional amp be liable for any loss or damage direct or consequential arising out of the use of or inability to use this product G This warranty is the only written warranty applicable to Elation Professional amp Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 39 ELAR QUAD BAR User Manual 2 0 www elationlighting com 15 TECHNICAL SPECIFICATIONS POWER SUPPLY Voltage Requirements 100 240V 50Hz 60Hz LIGHT SOURCE 4 x 10W CREE QUAD LEDs Life Time 100 000 Rated Hours May vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage
34. red Auto Program Part Auto Pro Part1 Auto Pro Part2 Auto Pro Part3 and tap ENTER to confirm selection Tap UP DOWN to select desired Program number Program 1 Program 10 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 1 EDIT PROGRAM Edit Program Edit the internal programs Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Edit Program is highlighted and tap ENTER Tap UP DOWN until Edit Program is displayed and tap ENTER 1 3 Tap UP DOWN to select desired Program number Program 1 Program 10 and tap ENTER to confirm selection Tap UP DOWN to select desired test or step Pro Test Step 01 Step 64 and tap ENTER to confirm selection Tap UP DOWN to select desired scene Sc001 Sc125 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 29 ELAR QUAD BAR User Manual 2 0 www elationlighting com EDIT PROGRAM Edit Scenes Edit the scenes of the internal programs 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Edit Program is highlighted and tap ENTER 2 Tap UP DOWN until Edit Scenes is displayed and tap ENTER 3 Tap UP DOWN to select desired scene number Scene 001 Scene 125 and tap ENTER to confirm selection 4 Tap UP DOWN to select desired function Strobe Dimmer Chase Effect
35. rews 1 Safety Cable Manual amp Warranty Card eS MANUAL UPDATES Please check www elationlighting com for the latest revision update of this manual CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or suggestions For service related issue please contact Elation Professional Service Hours are Monday through Friday 8 00 a m to 5 00 p m PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com Forum www ElationLighting com forum WARRANTY REGISTRATION The ELAR QUAD carries a two year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customers expense You may obtain a R A number by
36. s IP Ingress Protection followed by two numbers i e IP65 where the numbers define the degree of protection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture such as the ELAR QUAD BAR is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 UNPACKING Thank you for purchasing the ELAR QUAD by Elation Professional Every ELAR QUAD BAR has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible 4 ELAR QUAD BAR User Manual 2 0 www elationlighting com BOX CONTENTS e 1 68 Rated Power Cable e 1 3 Pin XLR Cable 1 Omega Bracket amp 8 Mounting Sc
37. shipped with the product Elation Professional amp shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professional amp concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professional amp factory unless prior written authorization was issued to purchaser by Elation Professional if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional amp under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional amp reserves the right to make changes in design and or improvements upon its products without any obligatio
38. ting com 7 UNDERSTANDING DMX DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers DMX allows all makes and models of different manufactures to be linked together and operate from a single controller This is possible as long as all the fixtures and the controller are DMX compliant A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light DMX data is sent out as serial data that travels from fixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use proper DMX cables and a terminator When using several DMX fixtures try to use the shortest cable path possible Never split a DMX line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain The ELAR QUAD BAR can be controlled via DMX 512 protocol The ELAR QUAD BAR is a 64 channel DMX fixture
Download Pdf Manuals
Related Search
Related Contents
WorkCentre M123/M128, WorkCentre Pro 123/128 CD Player Mode d`emploi détaillé tiptel VoiceRECORDER 300 alicate digital para corrente de fuga modelo: et-3140 Embedded System Tools Reference Manual Alpine SWR-10D4 XEMIO-858 LECTEUR MP4 / ECRAN TACTILE Manuel d`utilisation DRAGONE - ShopMania BIZ Copyright © All rights reserved.
Failed to retrieve file