1. After making any adjustments press SET again to get the OFF2 time displayed Repeatthis operation for the ON3 and OFF3 settings This may be set up to 23 hours 50 minutes after the first switch on time Further operations of the SET button will take you through any remaining days of the week to be programmed before arriving at the operating mode and ready to work at the times you have set HELPFUL HINTS 1 The and buttons are used to change times Press and release for small changes press and hold down and the time will run 2 You cannot set the first switch on time ON1 before mid night but you can set the OFF3 afte midnight so long as you don t try to exceed 23 hour 50 mins after ON1 3 The switching times have to be in sequence ON1 OFF1 ON2 OFF2 ON3 and OFF3 if you try to set OFF1 earlier than ON1 the display will stop at the ON1 time with the OFF symbol flashing The same thing will happen with other switching times e g be tween OFF1 and ON2 this time the ON symbol will flash 4 If you attempt to set the ON1 after the OFF1 time the ON symbol will flash and the OFF1 setting will follow the ON1 time being set to prevent incorrect programming The same feature applies with the other ON and OFF times and also between the OFF and ON times 5 Touse only two switching per day set the ON2 amp OFF2 times both to 12 00 6 If you get confused and wish to start the whole programming procedure again press the
2. SET and buttons together fora moment The module will revert to a mid night time display and the built in standard programme You will now have to set the clock again and then enter the programme you want 12 7 When you are making adjustments to timings if no button is pressed for 1 to 2 minutes the module will automatically revert to the normal operating mode 8 Toshutthe CH down for the Summer simply select the OFF option by means of the CH SELECT button Mynute SETTING INSTRUCTIONS FOR THE VOKERA 24HR 2 CHANNEL PROGRAMMER The Vokera 2 channel 24hr programmer will automatically switch your central heating system ON and OFF once or twice a day whichever you wish and at whatever times you choose You also have the option to obtain continuous ON or OFF operation It incorporates a rechargeable battery back up system to protect the programme during power cuts of up to 24 hours even though display will go blank The clock in the programmer has to be set to the actual time of day It must then be told at what times you want it to switch your Central Heating CH and Hot Water HW system ON and OFF This set of switching times is known as aprogramme The programmer has an in built programme of standard switching times They may well be right for you but if they are not exactly what you want you can change them The standard programme is shown in the table overleaf and for simplicity the switching oper
3. be changed press the YES button The display will show SET MON TUE WED THU FRI PROG NOTE the grouping of days in this way is to enable timings which apply to each and all of the weekdays to be set first followed by the opportunity to change one or more timings for any single day If you wish to set timings which will be the same for each weekday press the YES button The display will show SET cH MON TUE WED THU FRI PROG press YES and make the changes or press SET if no changes are required SETxHw The display will now show MON TUE WED THU FRI PROG press YES to make changes or SET if no changes are required SET The display will now show fen PROG press YES if you wish to make changes to Monday timings or press SET to change the display to SET TUE PROG Again press YES to make changes to Tuesday timings or continue to operate the SET button to access each weekday in turn If you press YES to make changes to the settings for a particular day the display will firstly show SET CH Press YES will allow changes to be made to the central heating settings but pressing SET will cause the display to show SETHW Press YES will allow the changes to be made to the hot water settings a further press of SET will move the display on the next day After any Friday changes have been made press SET The display will show mas SET SAT SUN PROG This gives you the ch
4. power surges can sometimes Mynute Fig 6 SETTING INSTRUCTIONS FOR THE VOKERA 7 DAY 2 CHANNEL PROGRAMMER The Vokera 2 channel 7 day programmer will automatical ly switch your central heating system ON and OFF once twice or three times a day whichever you wish and at whatever times you choose each day of the week It incorporates a rechargable battery back up system to protect the programme during power cuts of up to 24 hours even though display will go blank The clock in the programmer has to be set to the actual day of the week and time of day It must then be told at what times you want it to switch your Central Heating CH and Hot Water HW system ON and OFF for each day of the week This set of switching times is known as a programme The programmer has an in built programme of standard switching times They may well be right for you but if they are not exactly what you want you can change them The standard programme is shown in the table on the following page and for simplicity the switching opera tions are described as ON1 OFF1 ON2 OFF2 ONS OFF3 from now on SETTING THE CLOCK Use the chart to plan your own programme before proceeding Switch on the mains supply to the boiler then switch the mode selector switch 1 ON Press and release the button marked SET The display will show SET CLOCK Press and release the button marked YES to answer the ques
5. press the yes button if not you press the SET button again and this will change the display question to SET HW PROG Again you have to answer the question either with the YES button or by pressing the SET button which returns the programmer to the normal operating mode with the time of day displayed If you answer YES to SET CH PROG the display will show the time set for the first CH ON ON1 This can be altered in steps of 10 minutes by the use of the amp buttons When the display is showing the time you want press SET and the CH OFF OFF1 time will be seen Again changes can be made using the amp buttons before pressing SET to display the time for CH ON ON2 After making any adjustments press SET again to get the CH OFF OFF 2 time displayed This may be adjusted up to 23hrs amp 50 mins after the first switch on time Press the SET button again and the question SET HW PROG will be displayed SEP PROG By answering YES the same procedure can be followed for adjusting the HW timings before pressing SET one final time to go back to the time of day HELPFUL HINTS 1 The and buttons are used to change times Press and release for small changes press and hold down and the time will run 2 You cannot set the first switch on time ON1 before mid night but you can set the OFF2 after midnight so long as you don t try to exceed 23 hour 50 mins after ON1 3 The four swit
6. will be energised as will the circuit being controlled If you release the YES button the display will stop running and give you more than 2 3 seconds to think about a switching time Continue pressing YES andthe display will now run to the OFF1 time when it will pause again and the time switch will switch off It will then run to the ON and OFF times in turn pausing at each before moving to the next day and identifying the ON and OFF times in the same way The programmer will continue identifying the ON and OFF times in this way for each day in sequence until you press the SET button when it changes to the holiday setting mode Pressing SET button again returns the module to normal operating mode HOLIDAY SETTING NOTE this useful feature allows you to set the number of days you want your system to be permanently off before automatically switching on at the programmed time The programmer counts each pass through mid night as one day so if on Saturday morning you don t want the system on again until Tuesday morning you setthe counter to 3 If when the display shows SET H DAY you press the YES button the display will show OO By using the and buttons you can now set the number of days you want the system to be off a maximum of 99 days is possible Now press SET again and the display will be blank apart from H DAY Having counted down to zero the programmer will switch the system on at the times set for that da
7. Mynute Vokera heating for life standard efficiency system boiler 12e 16e 20e Users Instructions CE THESE INSTRUCTIONS TO BE RETAINED BY USER THE MARK OF QUALITY FOR THE INSTALLATION COMMISSIONING AND SERVICING OF DOMESTIC HEATING AND HOT WATER SYSTEMS Vok ra is a licensed o of the Benchmark scheme which ameo Pa e the standards of installation and commissioning of araor lomestic hot water systems in the UK INTRODUCTION Contents Page Introduction Dear customer N Do s and don t s Things you should know 1 1 gas appliances 1 2 electrical supply 1 3 guarantee registration card 1 4 benchmark log book 1 5 how does it work 1 6 dimensions 1 7 clearances Getting started 2 1 before switching on 2 2 appliance controls 2 3 lighting the boiler How to 3 1 top up the system 3 2 reset the appliance 3 3 shut down the system for short periods 3 4 shut down the system for long periods 3 5 care for the appliance What if 4 1 suspect a gas leak 4 2 frequently have to top up the system 4 3 the reset light is on 4 4 the appliance is due its annual service 4 5 need to call an engineer Setting the Vokera 5 1 Mechanical clock Mynute 5 2 Digital clock WIN DID AOA OIOI AAA a HR HR HR UOU ol oloon PP 5 3 Twin channel progra
8. an be found on pages 6 10 Ifan external time clock or programmer has been fitted please refer to the instructions supplied with such LIGHTING THE BOILER Ensure the gas and electrical supply to the boiler are turned on Turn the mode switch to the on position Refer to the particular instructions for the type of program mer or time clock fitted and ensure there is a demand for heating and or hot water If there is a room thermostat and or hot water cylinder ther mostat you should ensure these are also calling for heat When there is a demand for heating and or hot water via the above controls the boiler will go through an ignition sequence whereby the burner will light If the appliance fails to ignite during the ignition sequence allow a period of two minutes before re setting To adjust the output temperature of the appliance turn the thermostat knob clockwise to increase or anti clockwise to decrease When the appliance reaches the set temperature the burner will go off for minimum period of ap proximately 3 minutes When the programmer time clock or external ther mostats heating request has been satisfied the appliance will switch off automatically Mynute HOW TO 3 1 3 2 3 3 3 4 3 5 HOW TO TOP UP THE SYSTEM PRESSURE fig 2 The system pressure must be checked periodi cally to ensure the correct operation of the boiler The needle on the gauge should be reading be twee
9. ance for you WHAT IF NEED TO CALL AN ENGINEER If you think your boiler may have developed a fault please contact your installer or Vokera Customer Services 0870 333 0220 UK or 05655057 ROI have all your details to hand including full address and postcode relevant contact numbers and your completed appliance log book Mynute VOKERA TIMECLOCKS 5 1 5 1 1 SETTING THE MECHANICAL CLOCK The Vokera mechanical time clock can automati cally switch your boiler on and off at the same time every day of the week The minimum on or off period can be as little as 15 minutes The outer clock face consists of 96 black pins Each pin represents a time period of fifteen min utes When a pin is pushed towards the outside of the clock face the time clock is in an on position consequently when it is pushed towards the inner part of the clock face it is in an off position SETTING THE ON amp OFF TIMES Push the necessary amount of pins towards the outer clock face for the time period that you want the boiler to be on for example if you wanted the boiler to be on between 4 00PM and 8 00PM push out the 16 pins located between 16 and 20 on the clock face SETTING THE TIME OF DAY Grasp the outer clock face and turn clock wise until the correct time of day is opposite the black pointer SELECTOR SWITCH The time clock has a three position switch This switch over
10. ance to set timings which will apply to both weekend days by answering YES Further opera tion of the SET button accesses SAT and SUN for individual timing changes Pressing SET after finishing any weekend programme changes or pressing SET in answer to SET PROG returns the module to TEST Pressing SET again display SET HOL Pressing SET again returns the module to the normal operating mode MONDAY FRIDAY SATURDAY SUNDAY SWITOHING H W C H H W C H ON1 Start of first timed period of day ON 6 30am 6 30am 6 30am 6 30am OFF1 End of first timed period OFF 8 30am 8 30am 9 00am 9 00am ON2 Start of second timed period ON 12 noon 12 noon 12 noon 12 noon OFF2 End of second period OFF 12 noon 12 noon 12 noon 12 noon ON3 Start of third period ON 4 30pm 4 30pm 4 00pm 4 00pm OFF3 Final switch OFF 10 30pm 10 30pm 11 00pm 11 00pm Mynute 11 SETTING INSTRUCTIONS FOR THE VOKERA 7 DAY 2 CHANNEL PROGRAMMER If you answer YES to any of the detailed programming questions the following steps will apply The display will show the time set for the first switch on ON1 to occur for the day s concerned This can be altered in steps of 10 minutes by use of the and buttons When the display is showing the time you want press SET and the OFF1 time will be seen Again changes may be made with the and buttons before pressing SET to show the time for ON2 to occur
11. ations are described as ON1 OFF1 ON2 OFF2 from now on SETTING THE CLOCK Use the chart overleaf to plan your own programme before proceeding Switch on the mains supply to the boiler then switch the mode selector switch ON Press and release the button marked SET The display will show SET CLOCK Press and release the button marked YES to answer the question and the hour part of the display will flash Use the and buttons to change to the correct hour check AM or PM then press SET again This will cause the minutes part of the display to flash Use the and buttons to change the minutes as required then press SET again SET PROG The display will now show see later instructions for changing your programme Press the SET button again and the display will now show the time of day you have set Your programmer is now in the operating mode and ready to work using the built in standard programme times CHANGING YOUR PROGRAMME With the module in the operating mode and the display showing the actual time of day press the SET button The display will again show SET CLOCK but this has already been done so push the SET button again The display will now show SET PROG and as it is the programme settings which are to be changed press the YES button The display will show SET CH PROG Mynute NOTE If you wish to make changes to the ON or OFF timings for CH you
12. ching times have to be in sequence ON1 OFF1 ON2 OFF2 if you try to set OFF1 earlier than ON1 the display will stop at the ON1 time with the OFF symbol flashing The same thing will happen with other switching times e g between OFF1 and ON2 this time the ON symbol will flash 4 lf you attempt to set the ON1 after the OFF1 time the ON symbol will flash and the OFF1 setting will follow the ON1 time being set to prevent incorrect programming The same feature applies with the other ON and OFF times and also between the OFF and ON times 5 If you get confused and wish to start the whole programming procedure again press the SET and buttons together for amoment The module will revert to a mid night time display and the built in standard programme You will now have to set the clock again and then enter the programme you want 6 When you are making adjustments to timings if no button is pressed for 1 to 2 minutes the module will automatically revert to the normal operating mode 7 To shut the CH down for the Summer simply select the OFF option by means of the CH SELECT button 13 SETTING INSTRUCTIONS FOR THE VOKERA 24HR 2 CHANNEL PROGRAMMER PROGRAMMER OPTIONS Hot water and central heating can be operated independ ently The programmer gives you 4 options for both CH amp HW OFF Off all the time TIMED On Off at all periods set in programme ONCE On for one period each day ON1 gt OFF2 ON On a
13. efore switching the appliance on please familiar ise yourself with e How to isolate the appliance from the gas water and electricity supplies e How to check and top up if necessary the system water pressure e The time clock or programmer e Any external thermostats and their functions e The appliance controls APPLIANCE CONTROLS see fig 1 The appliance controls are concealed behind the front flap To gain access to the controls simply press the bottom centre of the flap and lift upward to engage the holding clip The appliance has a mode switch variable ther mostat system pressure gauge and an aperture for an integral clock or programmer The mode switch has three positions e Reset e Off e On The variable thermostat allows you to set the temperature of the water to your radiators and hot water cylinder not the hot water to your taps between 40 C min and 80 C max The pressure gauge shows the current pressure of the system the gauge should be set between 1 and 1 5 BAR When the appliance is operating the gauge may rise or fall slightly this is quite normal The minimum permissible level for the safe and efficient operation of the appliance is 0 5 bar Should the pressure fall below 0 5 bar the boiler shuts off automatically Depending on the type of controls specified by your installer you may have an integral Vokera time clock or programmer fitted to the appliance if so instructions c
14. esday 3 Wednesday etc e If setting the clock during British summertime press the 1h button once use a pencil or similar e Press the h button until the actual hour is shown in the display e Press the m button until the actual minutes are showing in the display e Now release the O button e The symbol between the hours and minutes display will start to flash this indicates that the clock is now keeping time see fig 3 8 Reset Button British Summertime Button Programme Button 4 amp gt Hour Button Fig 1 Select Button Minute Button Clock Button Display Day Button Vokera Digital Time Clock Fig 2 Fig 3 5 2 3 ENTERING on COMMANDS e Repeatedly press the Prog Button until the symbol appears in the clock display see fig 4 e Press the Day button until the desired group of days or desired day is shown e Press the h button until the desired hour for switching the boiler on is shown e Press the m button until the desired minutes are shown e Press the Select button until the symbol is shown see fig 5 e Press the button Fig 4 Fig 5 5 2 4 ENTERING _ off COMMANDS e Repeatedly press the Prog Button until the symbol appears in the clock display fig 4 e Press the Day button until the desired group of days or desired day is shown e Press
15. g This appliance must be earthed GUARANTEE REGISTRATION CARD Please take the time to fill out your guarantee registration card The completed warranty card should be posted within 30 days of installation BENCHMARK LOG BOOK The Benchmark Log Book is supplied with your boiler This important document must be completed during the installation commissioning of your boiler All CORGI Registered Installers carry a CORGI ID card and have a registration number Both shoulf be recorded in your Benchmark Log Book You can check your installer by calling CORGI direct on 01256372300 Failure to install and commission the appliance in accordance with the manufacturers instructions may invalidate the warranty This does not affect your statutory rights HOW DOES IT WORK Your Mynute boiler is a central heating boiler which supplies heated water to your radiators and hot water cylinder It is controlled by the time clock or programmer and any thermostats that your installer may have fitted The Mynute lights electronically and does not have a pilot light Inthe unlikely event of a fault developing with your boiler the supply of gas to the burner will be terminated automatically Mynute 1 6 DIMENSIONS HEIGHT 740mm WIDTH 366mm DEPTH 315mm 1 7 CLEARANCES REQUIRED ABOVE 150mm BELOW 150mm SIDES 12mm FRONT 600mm GETTING STARTED 2 1 2 2 2 3 BEFORE SWITCHING ON B
16. ll the time Obtain the options you require by using the SELECT buttons for CH amp HW to move the arrows in the display to the appropriate position Press the SET button again and the question SET HW PROG will be displayed STANDARD PROG H W C H ON 1 Start of first timed period of day ON 6 30am 6 30am SWITCHING OFF 1 End of first timed period OFF 8 30am 8 30am ON 2 Start of second timed period ON 4 30pm 4 30pm OFF 2 Final switch OFF 10 30pm 10 30pm STANDARD PROGRAM FOR 24HR 2 CHANNEL PROGRAMMER 14 Mynute Vokera heating for life Registered address Vok ra Ltd Borderlake House Unit 7 Riverside Industrial Estate London Colney Herts AL2 1HG enquiries vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 0999 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limited reserve the right to change specification without prior notice Consumers statutory rights are not affected A Riello Group Company Company Reg No 1047779 Cod 10023278 12 04 Ed 2
17. mmer oO INTRODUCTION Dear Customer Your Mynute boiler has been designed to meet and exceed the very latest standards in gas central heating technology and if cared for will give years of reliable use and efficiency Please therefore take some time to read these instructions carefully Do s and Don ts e Doensure that the system pressure is periodically checked e Do ensure that you know how to isolate the appliance in an emergency e Do ensure that you are familiar with the appliance controls e Do ensure that your installer has completed the appliance log book e Do not attempt to remove the appliance casing or gain internal access e Do not hang clothes etc over the appliance Fig 1 variable pressure Vokera thermostat gauge clock or programmer if fitted mode switch reset warning light 2 Mynute THINGS YOU SHOULD KNOW 1 1 1 2 1 3 1 4 1 5 GAS APPLIANCES Gas Safety Installations and Use Regulations In the interests of your safety and that of others it is a legal requirement that all gas appliances are installed and correctly maintained by a competent person and in accordance with the latest regula tions ELECTRICAL SUPPLY Please ensure that this appliance has been prop erly connected to the electrical supply by means of a double pole isolator or un switched socket and that the correct size of fuse 3 amp has been fitted Warnin
18. n 1 and 1 5 bar when the boiler is in an off position and has cooled to room temperature If the pressure requires topping up use the follow ing instructions as a guide e Locate the filling valve connections external to the boiler e Attach the filling loop to both connections e Open the filling valve slowly until you hear water entering the system e Close the filling valve when the pressure gauge on the boiler reads between 1 and 1 5 BAR e Remove the filling loop from the connections HOW TO RESET THE APPLIANCE When the reset light is illuminated the appliance will require to be reset manually Using the mode switch turn it two clicks to the left reset position then turn it back to the on position Allow a period of two minutes to elapse before turning the mode switch to the reset position IMPORTANT If the appliance requires to be reset frequently it may be indicative of a fault please contact your installer or Vokera Customer Services for further advice HOW TO SHUT DOWN THE SYSTEM FOR SHORT PERIODS The system and boiler can be shut down for short periods by simply turning the programmer or time clock to the off position see pages 6 10 or the instructions supplied It is also advisable to turn off the main water supply to the house HOW TO SHUT DOWN THE SYSTEM FOR LONG PERIODS If the house is to be left unoccupied for any length of time especially during the winter the system should be
19. rides the timed settings on amp off times of the clock Correct Time Pointer Vokera 24 Hour Mechanical Clock Mynute Selector Switch boiler on continously boiler working via time clock 0 boiler off continously VOKERA PROGRAMMERS 5 2 SETTING THE DIGITAL CLOCK The Vokera digital time clock will automatically switch your boiler on and off It has a total of twenty different switching commands consisting of ten on commands and ten off commands Each on or off command can be used to switch the boiler on or off at the same time e Every day of the week e Monday to Saturday e Monday to Friday e Saturday and Sunday Example Group of days On Off Commands used Mon to Fri 06 00 09 00 2 Mon to Fri 16 00 21 00 2 Sat amp Sun 08 30 10 30 2 Sat amp Sun 17 00 23 00 2 Total 8 used Commands free 12 unused 5 2 1 BEFORE PROGRAMMING Gently press and release the Res button with a pencil or similar this will clear the memory of all information This should only be done when you want to change or insert a complete new pro gramme 5 2 2 SETTING THE TIME OF DAY The real time clock has to be set to the actual day of the week and time of day to do this e Press and hold the button see fig 2 e Press the Day button until the actual day shows in the display 1 Monday 2 Tu
20. the h button until the desired hour for switching the boiler off is shown e Press the m button until the desired minutes are shown e Press the Select button until the C symbol is shown see fig 6 e Press the 6 button Mynute VOKERA PROGRAMMERS Once the programming has been completed you will have to press the Select button once only to the on position if the boiler has been programmed to be on at that particular time 5 2 5 ADVANCING OR LOCKING PROGRAMME COMMANDS By pressing the Select button you can advance the time clock to the next command setting from on to off or off to on or lock the time clock to a particular command on continuously or off continuously ON e OFF e ON CONTINUOUSLY e O OFF CONTINUOUSLY NOTE The actual time can be changed to account for British summertime by simply pressing then re leasing the 1h button HELPFUL HINTS e You can check and or alter the programme settings at any time by pressing the Prog but ton e The number of unused commands can be checked by pressing the Prog button until FR is displayed alongside the number of unused commands e In the event of a power failure the clock has a battery back up The programme will be held in the memory for approximately 2 weeks Charging time is 70 hours e Take a note of the settings you have pro grammed as local
21. thoroughly drained of all water The gas water and electricity supply to the house should also be turned off For more detailed advice contact your installer HOW TO CARE FOR THE APPLIANCE To clean the outer casing use only a clean damp cloth Do notuse any scourers or abrasive cleaners Mynute Fig 2 WHAT IF 4 1 4 2 4 3 4 4 4 5 WHAT IF I SUSPECT A GAS LEAK If you suspect a gas leak turn off the gas supply at the gas meter and contact your installer or local gas supplier If you require further advice please contact your nearest Vokera office WHAT IF HAVE TO FREQUENTLY TOP UP THE SYSTEM If the system regularly requires topping up it may be indicative of a leak Please contact your installer and ask him to inspect the system WHAT IF THE RESET LIGHT IS ON If the reset light is on it indicates that the boiler has failed to ignite or has overheated when this hap pens the boiler automatically shuts down and requires to be reset manually see 3 2 WHAT IF THE APPLIANCE IS DUE ITS AN NUAL SERVICE Advice for tenants only Your landlord should arrange for servicing Advice for homeowners Please contact Vokera Customer Services 0870 333 0220 UK or 05655057 ROI if you would prefer a Vokera service engineer or agent to service your appliance Alternatively your local CORGI registered engineer may be able to serv ice the appli
22. tion and the day part of the display will flash Use and buttons to change to the correct day then press SET again This will cause the hour part of the display to flash Use the and buttons to change to the correct hour check AM or PM then press SET again This will cause the minutes part of the display to flash Again use the and buttons to change the minutes as required then press SET again The display will now show SET PROG see later instructions for changing your programme Press the SET again The display will now show TEST again see later instructions Press the SET button again The display will show as SET H DAY 10 again see later instructions about this holiday setting feature Press SET once again and the display will show actual time of day and day of the week you have set PROGRAMME TEST As described earlier there is a place in the programming sequence where you will be given the opportunity to press YES when the display shows TEST This feature is available so you can quickly run through the ON and OFF times set to make sure they are what you want Answer YES and the display will show a time just past midnight on the morning of the day of the week you are actually in Now press and hold down the YES button again The time display will start to run and will pause for 2 3 seconds when it reaches the ON1 time for that day the ON indicator light
23. y If you wish to cancel the H DAY setting press any button and normal operation will be resumed Your module is now in the operating mode and ready to work using the built in standard programme times Mynute SETTING INSTRUCTIONS FOR THE VOKERA 7 DAY 2 CHANNEL PROGRAMMER PROGRAMME OPTIONS Hot water and central heating can be operated independantly The programmer gives you 4 options for both CH and HW OFF Off all the time TIMED On Off at all periods set in programme ONCE On for one period each day ON1 gt gt OFF3 ON On all the time Obtain the options you require by using the SELECT buttons to move the arrows in the display to the appropri ate positions Your module is now working using the standard programme times If these suit your needs there is nothing else to do You can temporarily override the normal switching times by pushing a button marked ADVANCE This switches ON to OFF to ON as you require but the normal programme switching times will not be permanently affected If you want to make changes to the programme it is suggested you write them down before making the changes CHANGING YOUR PROGRAMME With the module in the operating mode and the display showing the actual time of day press the SET button The display will again show SET CLOCK but this has already been done so push the SET button again The display will again show SET PROG and as itis the programme settings which are to