        INFRARED TEMPERATURE THERMOCOUPLE METER Model AX
         Contents
1.   3  Indication to measurement    4  Emissivity             5  Display zone    6  Display zone   i uR     i  D   DI    7  Average Maximum minimum Pi    Es   8  Indication to laser firing    rd  P i    9  Indication to back light                               10  Temperatuere units    11  Indications to low voltage of the batteries    4  OPERATION INSTRUCTION    TYPE  1  Press the ON OFF key to turn the Power on and Press the key again to Shift the measurement mode  between infrared or thermocouple     ELILIIIII WWW AXIOMET EU    2  Press the LASER key under the infrared state  The meter will enter the measurement state and  lunched a beam of red laser  Point the laser to the measured object and press the SCAN H key to  achieved the continuous temperature measurement     3  Press the SCAN H key under the thermocouple state and data will be held  Press the SCAN H key  again to return the measurement state      If you still need more operations  plaese see the desription of keys instruction   5  KEYS INSTRUCTION  1  TYPE ON OFF key    ON OFF  Press the key to turn the power ON and press the key once more  gt  2 sec  To turn the  power OFF     TYPE  Press the key to select the mode of infrared or thermocouple         SIA    2  aes key   Control the back Ligot on or off    3  UNIT key   Press the key to select alternate the two temperature units of   C and   F   4  MODE key   Press the key to select the mode of AVG  MAX or MIN    5  LASER key   Control the laser on or off in the i
2. AXIO       HHHH ME T    INFRARED TEMPERATURE  THERMOCOUPLE METER    Model AX 5002       USERS MANUAL    1  INTRODUCTION   Thank you for purchasing the infrared temperature thermocouple meter from us  Please take a few  minutes to browse through this user manual before you begin to operate the meter to ensure that  you are fully familiarized with how best to operate the meter as accurately and safely as possible     This meter combines two precision thermometers in one unit  a noncontact infrared thermometers  and a thermocouple thermometer  This meter can match standard type K sensor     A WARNING     Do not point laser directly At eye or reflective surface   1 1 Precautions safety measures    To get the best service from this meter  please read this user s manual carefully and observe the  detailed safety precautions strictly     1 1 1  During use    1  After abrupt ambient temperature changes  allow instrument temperature to stabilize for  30 minutes before using for measurement     2  Do not expose thermometer to excessive ambient temperatures   3  Keep the thermometer clean     4  The center spacing of the standard small thermocouple jacks is 7 9mm between the two prongs     5  When the battery voltage is under proper operation requirement  the  5 Esymbol will show on  the LCD and the battery need to be replaced with new     6  Do not use solvents to clean the meter   1 1 2  Maintaining the product  e Do not measure at a high temperature  high humidity places     e When n
3. he ideal working range of  the noncontact thermometer is between 25 mm and 250mm  1 and 10 inches   The field of view is  a circular measurement area approximately equal to the distance from the target to the unit     divided by 2  To ensure accurate measurements   measurement target must fill or exceed the field  of view     7  MAINTENANCE  1  Cleaning Instructions    The meter may be wiped down with a wet sponge or cloth using a mild water based detergent or  anti bacterial soap and rinsed under a gentle stream of cold water     NOTE   This unit is not designed for complete submersion or washing in water  2  Battery replacement    Use the following procedure     When the battery voltage drop below proper operation range the EE symbol will appear on the  LCD display and the battery need to be replaced     e Press the battery cover and towards arrowhead direction to open the battery cover   e Replace the battery with three new 1 5V batteries  AAA     e Replace the battery cover     ELILIIIII WWW AXIOMET EU    
4. nfrared state    6  SCAN H key    In the infrared state  press the key to measure the temperature  In the thermocouple state     Press the key a  Al icon will display on the LCD and the readout held in  Press the key once more  to cancel the hold function     7  Auto power of setting    When the meter is powered on  it is under auto power off mode  The meter will power itself off  after 25 seconds  infrared  or 20 minutes   thermocouple  if no key operation     Cancelled auto power off function  press the LASER key when power on unit the LCD display all  icons and the back light is on     MAMA NAO  WWW AXIOMET EU    5  EMISSIVITY AND FIELD OF VIEW   Emissivity  Emissivity is a term used to describe the energy emitting characteristics of a material   The higher the emissivity value a material has  the more infrared energy it will emit at a particular  temperature  Most organic materials range in emissivity between 0 85 and 0 98  This thermometer  has a fixed  non adjustable  emissivity of 0 95   Measuring objects with an emissivity of less then  0 95 will result in a lower than actual temperature reading on the display  Be aware of this  characteristic when measuring low emissivity objects e g  shiny  reflective metal objects     An effective solution is that using the black adhesive tape to cover the object surface  starting the  measurement until the adhesive tape   s temperature is same as the object   Field of View  The distance to spot ratio for this thermometer is 2 1  T
5. ot using the instrument for a long time  please remove the battery and avoid storing in  high temperature and high humidity     2  FEATURES  1  Display  Adigits LCD Display  2  Resolution  0 1  C 0 1  F    1  C 1  F thermocouple above 1000  C     ELILIIIII WWW  AXIOMET EU    3  Range     Infared   50 300  C   58  572  F   Thermocouple   200 1300  C   328 2372  F   4  Accuracy    Infared   50  20  C   5  C 9  F     20 300  C    1 5  odczytu   3  C 5  F   Thermocouple   200  100  C    0 2  odczytu   1  C 2  F      100 1300  C   0 1  odczytu  0 7  C 1 4  F                                   5  Emissivity  0 95   6  Field of view  2 1   7  Laser Power  less than 1 mw   8  Response time  0 5 second   9  Auto power off  25 seconds  infrared  or 20 minutes  thermocouple   10  Low battery indicator  EE   11  Operating environment  0 50  C  32 122  F   0 90 RH   12  Storage environment   10 60  C  14 140  F   0 80 RH   13  Dimension and Weight  121 L x60 W x30 H mm  about 180g     14  Accessories  DC1 5V AAA  x 3 pcs       A oO       K type thermocouple wire       String x 1 pcs                Plastic box x 1 pcs       Infrared temperature  thermocouple meter         User manual x 1 pcs    3  NAMES OF PARTS   3 1  Instrument Familiarization  1  sensor cover   2  infrared sensor   3  thermocouple jack   4  LCD display    5  function key    3 2  LCD Display   The meaning of the symbols represented by following   1  Indicating it is now in the data holding state   2  Type of thermocouple 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Bijlage 12 User manual for kluwer.cls  BIJSLUITER: INFORMATIE VOOR DE GEBRUIK(ST)ER  Operating Instructions for Evaluation Electronics Model  Lexmark X646ef MFP  Jamo i200 Black iPod Soundsystem  User`s manual Primor 1000 / 3000 / 3010 / Level 15    Manual Téc. CHT (pdf 0,8 MB)  King Canada 8488 User's Manual    Copyright © All rights reserved. 