1. standard IEC 601 1 item 6 8 2b The manufacturer is only responsible for effects on the safety the reliability and the performance of the appliance if e Installation additions adjustments modifications or repairs are carried out by personnel authorized by the manufacturer e The electrical installations within the room concerned satisfy the requirements laid down by IEC e The appliance is used in full accordance with the instruction manual which is solely a guide and no substitute for professional training The safe and effective use of this product largely depends on the skill of the operator We are not liable for any damages due to mishandling or improper and unauthorised use e The company reserve the right to change technical specifications designations and catalogue numbers without prior notice Note Ensure that your electrical wirings are well earthed with 1 line and 1 neutral phase and your voltage is between 220V 240V 50 Hz Ensure that the suction unit should not be lifted above human body level Dispose of used product packaging in safe manner so as not to harm stray cattle children and environment WARRANTY CARD Model No ____LL eee Lee LLL LLL INN eee eee Date of Purchase Dealer Name taal ANAND MEDICAIDS PRIVATE LIMITED Regd Office 33 16 Punjabi Bagh Extn New Delhi 110026 India Tel 91 11 25225225 25229206 42464264 Fax 91 11 25225062 E mail sales anandind com Works 146
2. 0 M I E Bahadurgarh Haryana 124507 India EC REP KALEIDOS SH VIA PONTIOA 4 2012 MILANO ITALY www anandind com Page 5 DOC ID NO 6304 REV 01 DATE 09 10 2010 www suction india com
3. An ISO 9001 2008 13485 2012 Certified Company Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For INSTAD CE 2195 Vacuum marked nozzle Bacterial Filter Vacuum Control Safety Jar with On Off Switch auto motor shut off system Connector for Battery Level Patient use Vacuum Gauge 1 Itr jar Dear Customer Congratulations on your purchase of this versatile and need oriented suction unit It will serve you well for years if properly looked after The medical professions have long felt the need for a light weight easy to move safe dependable and easy to regulate suction unit INSTAD fills this healthcare need to a degree unmatched by any other unit It is designed for use in hospitals nursing homes doctor s offices paediatric care ICU and home care Non corrosive and shockproof enclosure is pressure moulded in engineering plastic ABS giving smooth and easy to clean surface ASSEMBLY The pump based on piston system batteries and PC card are housed in the enclosure The panel has a vacuum gauge release valve for vacuum adjustment push to on push to off switch filter upon a motor shut sensor fitted safety jar and four neon lights indicating External power mains AC on Internal battery Vehicle battery Internal battery charging level NS N SA 1 2 3 3 The first is for AC mains second for internal battery pack third for vehicle battery and the last shows battery charging lev
4. agents as well as by the manufactures of sterilization disinfection units must also be followed where 1 Ltr PC Jar application temperature process duration and airing etc are concerned www anandind com page 2 DOC ID NO 6304 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For INSTAD BACTERIAL FILTER The replaceable filter element filters evacuated air before it enters the pump thereby infecting the environment It must be changed on normal days but immediately after vapours have entered or after infective suction has been done PUMP Bacterial Filter The unit is fitted with Piston type oil free pump provides reduced maintenance cost a Open the unit with the aid of an allen key provided and disconnect the tube from the inlet point on the pump housing b Take out the motorized pump fitted on and together with the platform c The fly valves sheet is placed in the top the four screws of which can be opened one for vacuum and the other for outlet The piston is fitted below the top and over the eccentrically rotated came Just wipe clean these parts and set the unit again d There are two openings small and U type large in both the top portions While fitting see that large U of the one face towards the small round of the other and small of the first face the large of the screws can be put back and tightened in their positions e Please run the unit an
5. cuum reading may be noted As a reference the table below shows several factors by which the indicated maximum vacuum value must be multiplied according to the altitude of location where the measurement is carried out Location Maximum Vacuum Location Sea level 1000m 2000m 4000m Factor 1 00 0 88 0 78 0 60 GUIDELINES FOR USE Before the unit is put on please see that 1 Two hexa bolts used as holdfast in transportation must be removed by ae rotating anticlockwise with the aid of a simple hand tool F 2 Jar be checked for any crack tubing and lid be tightly placed on the jar The angular connector must be inserted as far as the stop While unplugging twist and pull 3 O rings on the push in connector and safety jar are intact 4 Adjust vacuum before use Fully tightened clockwise knob means full vacuum Pust in connector JAR CLEANING AND DISINFECTING Polycarbonate jar PC is superior to glass 3 4th filling is recommended After each use jar lid over flow cut off valve catheters etc should be cleaned thoroughly When cleaning is necessary after infective fluid has been evacuated the jar lid safety jar filter housing tube cut off valve can be sterilized by autoclaving upto 120 C for 20 minutes Alkaline cleaning agents and disinfectants based on phenyel may not be used Adherence to hospital directives on hygiene is of prime importance The instructions provided by the suppliers of cleaning
6. d see its satisfactory functioning before housing is screwed up Unlike the rotary design NO LUBRICATION IS REQUIRED IN THIS PUMP The unit has not to be tampered with by any mechanic other than our factory engineer or the person authorized Pump Exhaust Outlet y DC Motor BATTERY REPLACEMENT Open the back plate of the unit remove negative and positive connections on the battery Remove the battery from the hook and install new battery Remember to charge the new battery for 8 10 hours for optimum performance Patient Sensor Filter Gauge Safety Release To e00 Jar t Valve Vehicle E EE Charging W Cord PC CARD Inlet Outlet MOTORIZED PUMP www anandind com Page 3 DOC ID NO 6304 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For INSTAD TROUBLE SHOOTING Possible source of trouble Check Action to be taken Power Supply Voltage power socket Main switch Set at ON Electrical cord Plug type plug connections damaged cord Motor does Not Run Check if the safety jar is activated Open the safety jar clean amp dry the jar and replace the cap for re use Leak within the pump or in the external Isolate the source of trouble by carrying out suction circuit the checks outlined External cause Push in connector O rings Lid gasket Condition Inadequate Suction Performance Bacteria filter housing o
7. el The patient tube is to be connected to the other nozzle on the lid Vehicle charging cord is to be connected on socket with threading provided on the side Antibacterial Filter element replaceable is slipped into the safety jar on top and the other end is connected to the slot on the jar lid The second angular nozzle tube goes to the patient The release valve for adjusting the negative pressure and the vacuum gauge are on the panel An on off switch cum pilot lamp fuse and the removable main lead connector are on the side www anandind com rages DOC ID NO 6304 REV 01 DATE 09 10 2010 www suction india com l Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For INSTAD TECHNICAL Housing Engineering moulded ABS plastic cabinet with built in handle and jar hangers Capacity 0 575 mm Hg 10 regulable at 14 Itrs min Pump type Oil free piston pump Jar 1 Itr collection jar Polycarbonate with mechanical overflow cut off system Tubing 8 mm ID x 2 mtr Silicon Vacuum Gauge Bourden type 5 cms 0 760mm Hg calibration Filter Bacterial filter Power 110 to 220 V AC and in built maintenance free 12 VDC 2 2 Ah battery or ambulance car socket cable provided Dimension amp Weight 33 x 14 x 29 cms 7 Kg Battery Backup 120 minutes on full charge VACUUM AT ALTITUDES The specified maximum vacuum refers to sea level According to local conditions and barometric pressure slight deviations in va
8. n Safety jar top Condition and absence of leaks Filter paper Condition position of housing BATTERY Charge the unit for 4 6 hours or replace battery Inadiquate battery back up Blockage or kink in tubing within the Isolate source of trouble as follows pump or in the external suction circuit Remove the safety jar leave the suction connection open If the vacuum gauge now indicates zero vacuum the cause is external External cause Bacteria filter safety jar overflow valve in the Investigate the whole external suction circuit lid float valve push in connectors tubing etc for blockage s float valve sticking kinked tubing and rectify If the vacuum gauge still indicates a vacuum Vacuum gauge indicates a vacuum Pump does not suck however the cause is internal www anandind com Page 4 DOC ID NO 6304 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For INSTAD TERMS OF WARRANTY Anand Medicaids Private Limited warranty the high quality and workmanship of each Anand s HI VAC for a period of one year subsequent to the date of delivery by the company During this period faulty material will be replaced free of charge This warranty does not extend to components that are subject to wear and tear in the course of normal operation or due to improper treatment maintenance as per instructions Further conditions in accordance with international

Download Pdf Manuals

image

Related Search

Related Contents

INSTRUCTION HANDBOOK - TA Triumph  Blanco Large Single Bowl Undermount 501-113-12 User's Manual  inno inh306 tire hold trailer hitch bike rack 3rd bike add on  ا ة ا  Manual de instalación  The complete, hand-held tester for RS-232 is many  Bpz 150.771    code sante pubilq liv 3 titre 1-2-1 R4312-1 à R4312-32  Toshiba Satellite 1115  