1. Usually it is 256 IWellIdx is the index of the charge well size saved in the NVRAM of the detector board It indicates the index of the assigned charge well size Valid charge well sizes are 1pF index 0 4pF index 1 7pF index 2 10pF index 3 11pF index 4 14pF index 5 17pF index 6 and 20pF index 7 The three arguments above will be retrieved when the spTestBoard work with no problem You can use the retrieved data IArrayMode is the array or mux order mode The Cal Sensors PbS PbSe detector uses array order mode and the Sens Array s PbS PbSe uses mux order mode It can be 1 for Cal Sensor s and 0 Sens Array s Usually SP uses the Cal Sensor s PbS PbSe detectors so if there is no special note for this value just set it as 1 RETURN If the board works successfully the function will return 1 If the board doesn t work properly the function will return other number and error message Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com spSetTECoolerEx long spSetTECoolerEx long const sSTECoolerOn TE Cooler On Off option 1 On 0 Off This function is used to turn on or off the TE cooler ITECoolerOn Informs whether the TE Cooler will be run or not If this value is 1 then the TE co
2. pixel The criteria to adjust the integration is to try different lengths of time with a reference signal representing the maximum possible signal level during the measurement until the peak value across the range of pixels is close to but not at 65535 We recommend trying to get the peak about 65000 This way you can be sure that you are getting an optimized measurement condition with no saturation of PbS PbSe detector elements Generating Meaningful Values The information you collect from the system is only the relative signal size at each detector pixel until it has been calibrated to absolute certified reference values That is in the raw data the pixel location represents spatial distribution of the PbS PbSe detector elements and the corresponding intensity is represented by a digital value Since we can adjust the strength of the light source and the integration time of the PbS PbSe detector this A D value only provides a relative representation of the real world parameters We address both of these problems We connect pixels to wavelengths by use of known emission lines e g SP calibration light sources or narrow band Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com filters across the range of pixels together with a table relating pixels to wavelength
3. prior to returning data to the calling procedure Valid values are 1 2 or 4 samples IpPixArray points to a read memory address with the long integers of the same pixel number as that of the detector The detector is usually installed inversely in the SM301 spectrometer so the memory location has to be also reversed RETURN If there is no problem on running it returns 1 Otherwise it returns other value and error message spStoreAllEx long spStoreAllEx This function is used to store all mux detector array operational data amp settings currently resident in the PIC processor s run time memory to the PIC processor s NVRAM for future retrieval to a known operating state after a mux controller board power cycle RETURN If there is no problem on running it returns 1 Otherwise it returns other value and error message Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com spCloseEx short spCloseEx This function is called to reset all default valued for spTestBoard upon closing of the application RETURN If there is no problem on running it returns 1 Otherwise it returns other value and error message Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Driv
4. 2Pro to correlate the physical locations of pixels on the detector with the known wavelength of the radiation falling on them This is done by identifying the pixel locations where the maximal of the known wavelength is at These peak intensity wavelengths and pixels are used Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com by spPolyCalc and spPolyFit to generate a correlating polynomial function which best represents all the data points We have found that using a third order polynomial function produced the most desirable results for most cases In cases where high dispersion elements are used lower order polynomial functions may have to be utilized due to the limited known wavelengths available from the calibration lamps Calibration Files Each unit s calibration set is included in the SM32Pro software settings This text file contains calibration data of the form DataX Wavelength Pixel The file also contains the regression coefficients AO value A1 value B3 value that satisfy the equations Li A0 A1 Pi A 2 Pi2 A 3 Pi3 Pi B0 B11i B21i2 B 3 I i3 The A values are the coefficients for conversions from a pixel number to a wavelength in nm by use of the above first third order polynomial function The B values allow the co
5. Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com SM32Pro SDK Spectrometer Operating Software USER MANUAL SM301 SM301EX Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Table Of Contents Warranty And bAbtysanssassksensNeatnda tale da lend hilt dead 3 Quick Start Installation Guide 22 4 System REQUIFEMENMS cece cece eeeeeeeee cette ee eeeeeeeaaaeeeeeeeeeeeeeeceaaaeeeeeeeeeeeeeeeeneeeeeeeees 5 Getting rotated eet ae tae te ate he hoe en eden eh one ten ote cement aauedemeahed 6 Using the SP PIO anes ua on sesvnensee eee 8 General Overview rrnnnnnnnnnnnonnnnnnrvnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnennnnnnnnnnnennnnnennee 9 SPR EUNCHONS surrer E E ee 11 Alphabetical SDK Functions aars RANG 13 18 PIE BOT Noi Ea aee aea EEEE EE EAEE EE E cette E EA T ETT 13 5 bes 60 gt EE 14 SPE ST TEMP steph ced ai cect ct neta hanadeetcceteecnesutderaasncdttcrundanndnitececrandatanaadeees 14 see GRE 15 spBalance EX se ce ea ee Sc ae Sete eee eet eee 15 SPREDTE Se ieee ea 16 5 be 10 CAM EX EN 16 SPCIOSCEN seerne eee 17 SPPOMF ee 18 SPA vr 19 Spectral Products
6. Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Warranty And Liability This SM product is warranted against defects in material and workmanship for a period of one year from the date of shipment During the warranty period Spectral Products SP will without charge repair or replace at its discretion the defective product or component parts For warranty service or repair this product must be returned to a service facility designated by SP For products returned under warranty the Buyer shall prepay shipping charges including shipping charges duties and taxes for products returned to SP from another country and SP will pay for shipping charges to return the product to the Buyer This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations modifications or repairs if the serial number is altered defaced or removed the improper or inadequate maintenance by the Buyer Buyer supplied software or interfacing operation outside of the environmental specifications for the product or improper site preparation or maintenance No other warranty is expressed or implied SP shall not be liable for any consequential damages including without limitation damages resulting from loss of use as permitted by law Spectral Produc
7. alue and error message spBalanceEx long spBalanceEx long const ITECoolerOn TE Cooler On Off 1 0 long const IWellIndex Charge well size index 0 3 This function is used to balance the detector The input light should be turned off or blocked completely before running this function ITECoolerOn Informs whether the TE Cooler will be run or not If this value is 1 then the TE cooler will be on If 0 the cooler will be off IWellIndex is the index of the charge well size saved in the NVRAM of the detector board It indicates the index of the assigned charge well size Valid charge well sizes are 1pF index 0 4pF index 1 7pF index 2 10pF index 3 11pF index 4 14pF index 5 17pF index 6 and 20pF index 7 RETURN If there is no problem on running it returns 1 Otherwise it returns other value and error message Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com spReadDataEx long spReadDataEx long const IBit A D conversion resolution 16bit long INumAve Number of data samples to average 1 2 or 4 long pIPixArray The array in which spectral data is stored IBit is the A D conversion resolution bit The current ADIC board has 16bit INumAve indicates the number of data samples to average
8. ation about all DLL functions in the ADICLib dll refer to the help file ADICLib256Help chm for it First spTestBoard should be called to get the appropriate information of the board You can trace some basic setting values from this function To turn on or off the TE cooler run spSetTECoolerEx With spReadTemp you can check the current cooling temperature status The spSetIntTimeEx is for setting the integration time You can set it from 10usec to 220msec Integration time is the time period the detector pixels are exposed to light before the resulting charges are read out A longer integration time can allow you to detect a lower light level signal The longer your integration time is the more background signal will accumulate The PbS PbSe detector should be balanced before getting the signals from the detector spBalanceEx is for the balance of the detector Please be sure that this spBalanceEx is for setting the stable base line The input light should be turned off or blocked completely before running this function Reading the signals from the detector is carried out by spReadDataEx By using the spStoreAllEx you can store all detector array operational data and settings currently resident in the PIC processor s run time memory to the PIC processor s NVRAM for future retrieval to a known operating state after a mux controller board power cycle Using Curve Fitting to Calibrate SM32Pro Curve fitting is used in SM3
9. ctral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Using the SP Libraries For Visual C C you must include the correct include file and lib file for the functions you are calling For Visual Basic please include the correct BAS file The function declarations listing in this file demonstrate the correct data types To passa pointer or array to a DLL from Visual basic simply pass the first element of the array IE SampleData 0 Please refer to the samples or contact us if you need any further technical assistance Procedure for using the dll with VC 1 Copy SPAbUSBIRCS dlI from SDKs SDK_SM301 to your work or windows system folder 2 Copy SPdbUSBIRCS lib from SDKs SDK_SM301 to your work or release folder 3 Add this SPdbUSBIRCS lib to the project settings link object library module Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com General Overview Some basic fundamentals of utilizing the SP SDK functions All SP s DLL functions are based on the ADICLib dll that the manufacture provided To get more detailed inform
10. e Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com spPolyFit long spPolyFit float x Array of independent variables float y Array of dependent variables short numPts Number of points in independent and dependent arrays float coefs Pointer to array to hold calculated coefficients index from 0 to order short order Order of polynomial This curve fitting function is used to find a polynomial function to calculate the wavelength of a given pixel This function is used for calibration purposes Either a calibration light source or a series of narrow band filters are scanned and the pixel locations of all known peaks are identified along with the known wavelength at that peak These peak locations and wavelengths are stored in the arrays x and y respectively The arrays indices should range from 0 to Number of Points 1 They are passed to the function along with a requested order for the polynomial fitting function and an array large enough to hold the coefficients This array is then used with spPolyCalc to calculate wavelength from pixels x is an array containing the independent variables It should range from 0 to numPts 1 y is an array containing the dependent variables It should range from 0 to numPts 1 numPts is the number of points in the variable arrays coefs is a pointer to the array that will contain the polynomial coefficients It should
11. nversions from a desired wavelength in nm to a pixel number Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com SDK Functions Data Acquisition spTestBoard Used by the program to test the acquisition board spSetTECoolerEx Used by the program to turn on or off the TE cooler spReadTemp Used by the program to read the current TE cooler temperature status spSetintTimeEx Used by the program to set integration time spBalanceEx Used by the program to balance the PbS PbSe detector spReadDataEx Used by the program to collect spectral data spStoreAllEx Used by the program to store all operational data and settings spCloseEx Used by the program to reset all board options upon resetting the software Calibration spPolyFit This function calculates the coefficients for a polynomial curve fitting function given an array of independent variables and a corresponding array of dependent variables Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Used by the program to generate a calibration function from pixels to wavelength spPolyCalc This function calculates a
12. oler will be on If 0 the cooler will be off RETURN If there is no problem on running it returns 1 Otherwise it returns other value and error message spReadTemp long spReadTemp long ITemp TE cooler temperature status This function is used to read the TE cooler temperature status This function has to be run only when the TE cooler is ON ITemp is the TE cooler temperature status returned The returned value will be between 100 and 100 If the TE cooler is running properly it is supposed to be 0 RETURN If there is no problem on running it returns 1 Otherwise it returns other value and error message Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com spSetintTimeEx long spSetIntTimeEx long const IIntegTime new integration time 3 65535 This function is used to change the integration time IIntegTime is the integration time The real integration time to be set in the detector board is IIntegTime X10 3 microseconds This number should range between 3 and 65535 The minimum integration time possible is 10usec lIntegTime 3 and the maximum is 220msec lintegTime 65535 To set 1msec set the IIntegTime as 300 RETURN If there is no problem on running it returns 1 Otherwise it returns other v
13. polynomial function given the independent variable and a coefficient array Used for determining the wavelength for a given pixel location Procedure of getting data spTestBoard Test the detector board to see if it is working properly spSetTECoolerEx Turn TE cooler on off spSetintTimeEx Set integration time spBalanceEx Balance the PbS PbSe detector spReadDataEx Read acquired data spStoreAllEx Store all operational data and settings spCloseEx Reset all the values to default values should be called at the exiting of program Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Alphabetical Function Reference spTestBoard long spTestBoard long IIntTime Integration time long IPxINum Pixel number of the detector long 1WelllIdx Charge well size index 0 1pF 1 4pF 2 7pF and 3 10pF long IArrayMode Array mode 0 Sens Array 1 Cal Sensors This function is used to test the resources of the IO board If the communication with the PbS PbSe detector board works well some basic operational data amp settings will be retrieved from the EEPROM NVRAM on the board IIntTime is the integration time saved in the NVRAM of the detector board IPxINum is the total pixel number saved in the NVRAM of the detector board
14. range from 0 to order 1 order is the desired order of the polynomial We have determined third order to be the optimum for wavelength calibration for most cases RETURN This function will return 1 if the function is successful Otherwise it will return negative Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com spPolyCalc void spPolyCalc float coefs pointer to an array containing the polynomial coefficients short order the order of the polynomial equation float x the pixel number float y the value to be calculated This function calculates for the following formula y 20 a1 1 a2 x 2 aN x N where specified multiplication and specifies to the power of coefs is a pointer to an array containing the polynomial coefficients These can be calculated using spPolyFit order specified the order of the polynomial equation and must be less than or equal to the number of elements in coefs x is the independent variable in this case the pixel number y is the value to be calculated RETURN None
15. s in nanometers Curve fitting functions can then be applied to generate a polynomial function for the conversion of all other pixels to wavelengths We address the second problem in one of two ways Both ways involve normalization Normalization involves measurements of signal strength based on its ratio with respect to reference signal intensity If we are only interested in the spectral distribution of the sample signal then we can normalize a sample signal scan to one reference value by for example intensities of all the array elements divided by the peak intensity If we want to measure percent transmission the light can be measured first with only air in the light path as 100 reference and then the sample can be inserted into the light path anda sample scan followed Consequently the divisions of sample scan readings by the 100 reference yields the relative transmission values or percent transmission when multiplied by 100 For reflectance measurement similar practice can be applied and a high reflector can be used as a reference air in many cases Background Scan It is strongly recommended that a measurement be taken prior to any sample scan in which no external light but only the detector noise will be sensed and subsequently subtracted from all the following measurements This will subtract thermally generated background DC offset level and statistically establish a baseline of zero for all subsequent measurements Spe
16. ter A D board unless a different interface was requested Cable and Adapter Any accessories ordered Note Package contents may vary from unit to unit and order to order If you have any questions about the contents of your package please contact the support team referred to in the back of this manual Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Getting Started Welcome to the Spectral Products SM32Pro Software Development Kit This kit documents a library of functions for accessing the USB Data Acquisition board used by the PbS PbSe detector units SM301 and SM301EX Two fundamental detector imaging concepts are the Collection of Data and Generating Meaningful Values from that data Collection of Data In our PbS PbSe detector spectrometer the light is dispersed across PbS PbSe 256 pixel detector array Data is collected by each pixel and converted to a relative value by the analog to digital A D converter ranging from 0 to 65535 16bit and representing the intensity of the light at each pixel We are able to control the amount of time that the pixels collect light and thus read signals of varying strengths Using this library of functions you will be able to adjust the signal capture time Integration Time and collect the converted signals from each
17. ts Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com Quick Start Installation Guide This quick start installation guide will walk you through the quick and easy installation of the SM software package you have chosen Please follow the instructions closely to complete the installation of your product 1 Insert the SM installation CD into the appropriate CD Rom drive 2 When the auto run starts cancel the installation 3 Explore the contents of the CD and copy the SDKs SDK_SM301 folder to any folder or directory on your local drive Spectral Products Spectrometers Spectrophotometers Color Instruments Spectrographs Monochromators 111 Highland Drive Putnam CT 06260 USA PHONE 860 928 5834 FAX 860 928 2676 http www spectralproducts com System Requirements Check that your computer meets the minimum requirements for the SM32Pro system Requirements for the Software Any IBM compatible computer A hard drive with at least 50 MB free space A CD ROM A VGA or compatible display 32 MB RMA or higher mouse or other pointing device Microsoft Windows 98 98SE ME NT 2000 and XP Check System Package Contents Check that your SM system package contains all of the required components Common system packages contain the fallowing Spectrome