Home
        NI PXI-1045 Power Supply Shuttle User Guide
         Contents
1.    3 3 V  lt 0 5     12 V  lt 0 5     5 V  lt 0 5     12 V  lt 0 5                    National Instruments Corporation 5 NI PXI 1045 Power Supply Shuttle User Guide    Maximum ripple and noise  20 MHz bandwidth                          Voltage Maximum Ripple and Noise   3 3 V 50 mV pp    12 V 120 mV pp    5 V 50 mV pp   12 V 120 mV pp          Over current protection           eee All outputs protected from short  circuit and overload with  automatic recovery when the  short or overload is removed   Over voltage protection     140 to 150  above nominal  output voltage    E EEEE 120 to 130  above nominal  output voltage    5 V   12 V   12 V    Power supply shuttle MTTR    Replacement in under 5 minutes       1 To reset over voltage protection  remove the MAINS for 30 seconds and then power up     NI PXI 1045 Power Supply Shuttle User Guide    ni com       National Instruments     NI     and ni com    are trademarks of National Instruments Corporation   Product and company names mentioned herein are trademarks or trade names of their respective  companies  For patents covering National Instruments products  refer to the appropriate location   Help  Patents in your software  the patents  txt file on your CD  or ni com patents        2003 National Instruments Corp  All rights reserved     323693A 01       Sep03    
2.  1045 Power Supply Shuttle  you need the  following items        Q PXI 1045 chassis  the unit being repaired    Q PXI 1045 power supply shuttle   UO Read Me First  Safety and Radio Frequency Interference  Q    NI PXI 1045 User Manual  provided with the chassis  also available  at ni  com  support        D    Number 1 Phillips screwdriver    Description       Refer to Figure 1 to locate user accessible components on the power supply  shuttle                    A REE a O  R ood    S  y  LI    a                                                                                                                                                                                                                                                                                                 1 Circuit Breaker 7 Remote Inhibit and Voltage Monitoring Connector  2 Chassis Ground Screw 8 Fan Speed Selector Switch   3 Filter Cover 9 Power Supply Shuttle   4 Filter Retainer Screws 10 Mounting Screw   5 10 MHz REF OUT BNC 11 Universal AC Inlet   6 10 MHz REF IN BNC          Figure 1  PXI 1045 Power Supply Shuttle Rear Panel    NI PXI 1045 Power Supply Shuttle User Guide 2 ni com    Installation and Maintenance       The information in this section is for qualified service personnel only  Read  the Read Me First  Safety and Radio Frequency Interference document  included with your kit before using the power supply shuttle     UN Caution Many components within the PXI 1045 chassis under repair are sus
3. A  USER GUIDE    NI PXI 1045 Power Supply Shuttle    This document explains the installation and maintenance of the  NI PXI 1045 power supply shuttle  The NI PXI 1045 power supply shuttle  is a replacement part for the PXI 1045 chassis     Introduction       To minimize downtime caused by a power supply failure  the PXI 1045  chassis has a modular power supply shuttle  This power supply shuttle  includes the chassis power supply  cooling fans  and fan control circuitry   Key features of the power supply shuttle include     e Universal AC input with automatic voltage and frequency ranging  e  Over current protection through push reset circuit breaker  e Remote voltage monitoring and inhibit through a rear panel connector    e Temperature sensing module that can adjust fan speed based on  air intake temperature to minimize audible noise    e Circuitry to control a front panel LED that indicates power supply  failure    Unpacking       Carefully inspect the shipping container and the power supply shuttle for  damage  Check for visible damage to the metal work  Check to make sure  all handles  hardware  and switches are undamaged  Visually inspect the  inside of the shuttle for any possible damage  debris  or detached  components  If damage appears to have been caused during shipment  file  a claim with the carrier  Retain the packing material for possible inspection  and or reshipment     Qr NATIONAL  p INSTRUMENTS     What You Need to Get Started    To set up and use the NI PXI
4. back of the chassis     Installation    Ensure that there is no visible damage to the new power supply shuttle   Verify that the housing and connector on the new power supply shuttle  have no foreign material inside  Remove the protective cap on the   10 MHz REF D sub connector that interfaces with the chassis backplane   Install the new power supply shuttle into the opening on the rear of the  chassis  Replace and tighten the ten mounting screws with a Phillips  screwdriver  maximum torque of 5 in  lbs         National Instruments Corporation 3 NI PXI 1045 Power Supply Shuttle User Guide    Configuration    Connecting Safety    The fan speed selector switch is on the rear panel of the power supply  shuttle  Refer to Figure 1 to locate the fan speed selector  Select HIGH for  maximum cooling performance  recommended  or AUTO for quieter  operation  When set to AUTO  air intake temperature determines the fan  speed     Ground    UN Caution The power supply shuttle is designed with a three position NEMA 5 15 jack that  connects the ground line to the chassis ground  To minimize shock hazard  make sure the  electrical power outlet you use to power the chassis has an appropriate earth safety ground     Specifications    AC Input    If your power outlet does not have an appropriate ground connection  you  must connect the premise safety ground to the chassis grounding screw   Refer to Figure   to locate the chassis grounding screw  To connect the  safety ground  complete the follo
5. ceptible to  static discharge damage  Service the chassis only in a static free environment  Observe  standard handling precautions for static sensitive devices while servicing the chassis   Always wear a grounded wrist strap  or equivalent  while servicing the chassis     Caution Always disconnect the AC power cable before cleaning or servicing the chassis      gt   gt     Caution Never connect the AC power cable to the power supply shuttle until you install it  in a PXI 1045 chassis  Do not use  test  or configure the power supply shuttle outside of a  chassis     The power supply shuttle is a replacement part for the PXI 1045 chassis   The MI PXI 1045 User Manual contains all of the most up to date chassis  service procedures  including removal and replacement of power supply  shuttles  The chassis includes a hardcopy of the NI PXI 1045 User Manual   additionally  you can download a softcopy from ni com support     Removal    Before attempting to replace the power supply shuttle  verify that there is  adequate clearance behind the chassis  Set the power switch on the front  panel to the Off  nonrecessed  position and disconnect the power cable  from the power supply shuttle on the back of the chassis  Identify the   10 mounting screws that attach the power supply shuttle to the chassis   Refer to Figure 1 for the mounting screw locations  Using a number 1  Phillips screwdriver  remove the screws  Pull the two rear handles of the  power supply shuttle to remove it from the 
6. wing steps     1  Connect a 16 AWG  1 3 mm  wire to the chassis grounding screw  using a grounding lug  The wire must have green insulation with a  yellow stripe or must be noninsulated  bare      2  Attach the opposite end of the wire to permanent earth ground using  toothed washers or a toothed lug     Input voltage range n e e 100 240 VAC  Operating voltage range  oo    90 264 VAC   Input frequency    eee eects eeeeeees 50 60 Hz   Operating frequency range             ee 47 63 Hz   Input current rating    seese 10 5 A  Over current protection          cee 12 A circuit breaker         The operating range is guaranteed by design     NI PXI 1045 Power Supply Shuttle User Guide 4 ni com    Line regulation    SiS UN egnan EEEE R a  lt t1   OV AEE  lt t1   I2 NVocrinn inean Ss  lt t1   EFFICIENCY sistens ienien iiaa 70  minimum  Power disconnect       sssseseeseseesseeesereesereee The AC power cable provides    main power disconnect   Depressing the front panel power  switch controls the internal  chassis power supply that  provides DC power to the  CompactPCI PXI backplane  You  also can use the rear panel 9 pin  D sub connector to control the  internal chassis power supply     DC Output    DC current capacity  Imp                    Voltage 0 45   C 45 50   C 50 55   C    3 3 V 40 A 37A 32A   5 V 59 A 55 A 48 A   12 V 8 5 A 8 5 A 8A   Peripheral slots   12 V 05A 05A 0 5 A  System slot   12 V 4 5 A 45A 45A             Load regulation                      Voltage Load Regulation
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Tanita BF-625 User's Manual  PECTINE RUBAN JAUNE  m68evb908ql4 operation  Passport Moxi 3G user guide,360 BTEgd_eng  BTscale User manual - Computer Systems @ JSI  Cassetto scaldavivande - V  Télécharger l`index en PDF - Transrural initiatives La revue des  MANUEL D`UTILISATION Tablette tactile Wi  3A2841D GBL 7500 Box Lubricator Pump or GBL Shaft  Pourquoi les murs auraient-ils des oreilles ? : Vers un    Copyright © All rights reserved. 