1. 2 99 002
2. Digi Pas A division of VENTURA Group of companies USER MANUAL Waterproof Torpedo Digital level DWL 280Pro 0 05 Resolution a P67 certified bY T V i Please take note that the device contains STRONG MAGNET This user manual is printed in small font size for paper saving purpose to protect the environment Softcopy is available at http www digipas com catalog manual CE FE fous Product of Singapore Calibration Instruction 1 Turn off the device press amp hold Alternate Zero and then ON OFF buttons simultaneously release when the display show flashing CAL1 2 a Place the device on a flat and clean surface press MODE button once the screen will display countdown wait until screen countdown reach 1 and show CAL2 b Rotate the device 180 parallel to the surface then press MODE button again the screen will display countdown wait until screen countdown reach 1 and show CAL3 c Position the device right side vertically 90 on a level surface press MODE button again the screen will display countdown wait until screen countdown reach 1 and show CAL4 d Rotate the device 180 parallel vertically to the surface 90 then press MODE button again the screen will display countdown wait until screen countdown reach 1 3 Calibration Done Note Ensure the device is kept still during ca
3. Temp 30 C 70 C Battery 3 x AAA 1 5V Battery Compartment Loosen screw 1 then pull rubber cap in the direction 2 Next turn the battery cap counter clockwise to remove batteries amp Caution Please note that the battery cap must be tightened until the O Ring is compressed into the space between the battery cap and battery compartment Failure to do so could result in water seeping into the battery electronics compartment Features Power on off Press amp hold the ON OFF button for 2 second to turn ON the device Press the ON OFF button again to turn OFF the device Note The device will auto turn off if idle for 7 minutes Hold Function Press the Hold button to freeze measurement value on the display Press again to unfreeze Mode Function Press the Mode button to switch between Degree slope mm M amp In Ft measurement Buzzer Sound Function Press amp hold the Alternate Zero button to turn ON or turn OFF the buzzer sound at 0 amp 90 Sound indicator icon diagram item 18 will be displayed on screen when the buzzer sound is turned ON Alternate Zero Function At any point of time press the Alternate Zero button to activate the function to set any angle to 0 as reference Once activated the alternate zero icon diagram item 13 will appear on screen To exit the function for actual angle measurement press the Alternate Zero butt
4. libration A Caution Digi Pas device is calibrated in the factory for maximum accuracy User can re calibrate when necessary Please refer to www digipas com for video demonstration on how to calibrate the device Cleaning Keep the level dry and clean Remove any moisture or dirt with a soft dry cloth Do not use harsh chemicals strong detergents or cleaning solvents to clean the level Do not submerge device in water while cleaning Wiping or cleaning on device surface is sufficient Device Overview 1 Rubber end cap 2 Vertical spirit vial 3 LED display 4 ON OFF button 5 HOLD button 6 MODE button Degree mm M In Ft amp slope 7 Alternate Zero button 8 Horizontal spirit vial 9 Magnet 10 AAA Battery 1 5V Not Included 11 Battery cap 12 Battery screw 13 Alternate zero indicator 14 Battery indicator Calibration Illustration STEP 1 E g STEP 2a Table Surface Press amp hold Alternate zero amp ON OFF buttons simultaneously Press Mode button ONCE Press Mode button ONCE 2 C F 90 Press Mode button ONCE 2 B 2 Press Mode button ONCE 15 Level directional arrow indicator 16 Level measurement value 17 Unit indicator 18 Sound Indicators 19 HOLD Indicators Registered Design Technical Specification Dimension 230 x 57 x 28 Weight 370 Gram Operating Temp 20 C 60 C Storage
5. on again to turn OFF the function Warranty Digi Pas Digital level is warranted to the original purchaser to be free from defects in workmanship and material JSB Tech will at its option repair or replace any detective part which may malfunction under normal and proper use within a warranty period of 1 one year from the date of shipment This one year warranty clause is NOT applicable to European Union EU member states Purchases made in EU member states will be covered by the existing consumer laws across the European Union which provide statutory warranty rights in addition to the coverage of one year warranty period The foregoing warranty shall not apply to defects resulting from misuse abuse or transfer by the Buyer Buyer supplied software or interfacing unauthorized modification or operation outside of environmental specifications for the product JSB Tech does not warrant that the operation of the instrument software or firmware will be uninterrupted or error free The exclusive remedy under any and all warrants and guarantees expressed herein and we shall not be liable for damages from loss or delay of equipments uses consequential or incidental damage No other warranty is expressed or implied JSB Tech specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Distributed by Manufactured by JSB TECH Pte Ltd Email info digipas com www digipas com JIM 2 0008

Download Pdf Manuals

image

Related Search

Related Contents

Philips Sync & Charge Cable DLC2407  Operating Instructions for Pressure Sensor with Ceramic Sensor  GNU/Linux AI & Alife HOWTO - The Linux Documentation Project  manual - NRL Refrigeration    Alcatel-Lucent APX 1000 User's Manual    ZENworks 11 SP3-Server-Installationshandbuch  LCR-915/916 Series User Manual  Serie 914X  

Copyright © All rights reserved.
Failed to retrieve file