Home
Product Catalog English 2011 - 5.cdr
Contents
1. Close Talk Conference System is designed for and all it s certifications are based on the use of the industry standard Cat 6 S FTP grade Ethernet cable type The S FTP formerly known as S STP grade means double shielding i e all four signal pairs have an individual shield and then the four pairs have a common outer shield There are several other Ethernet cable types and categories on the market namely U UTP UTP Unshielded Twisted Pair F UTP FTP Foil Shielded Twisted Pair and U FTP STP Shielded Twisted Pair Although the system will work with other cable types thanS FTP S STP it will not operate according to specifications it s safety against eavesdropping is severely reduced and the warranty is void Power under voltage states may occur resulting in system instability Close Talk Conference System supplies ready made cables in lengths of 5 10 15 25 30 and 50 meters which enables quick and problem free installation please see next page for ordering information Itis also possible to use custom built cables but please note Always use Cat 6 S FTP S STP cables Use shielded connectors When using RJ 45 Cable Joiners Extenders use a shielded type Use the industry standard straight RJ 45 Ethernet patch cable pin out Follow the installation rules found in the full product catalog Important Close Talk Conference System uses proprietary signaling not Ethernet Only connect Close Talk equip ment to a Clos
2. Avoid moisture to enter the unit Approvals CE and FCC approval Order code TU 100 02 Tender Specification The Transceiver Unit is to comply with all relevant CE regulations The unitis intended for vertical transmission and reception of infrared light with an 875nm wavelength Emission power shall be of harmless nature The unit shall transmit two channels and have a broadband receiver for analog FM modulated signals in the 2 6MHZz carrier frequency range The unit shall be connected to the system using industry standard CAT 6 S STP grade network cables Operating power shall be provided via the cable at up 30 metre segment lengths Operating power voltage levels and power consumption shall provide for safe mounting without special cooling arrangements The unit shall be flush mounted face down in a standard BOSE 112x112mm ceiling speaker pattern using four screws for fastening The unit is to be of round front plate design Front plate material is to be steel and be of white colour At request other colours can be provided Transceiver Unit model Close Talk type TU 100 02 or equivalent Transceiver Unit TU 100 03 The TU 100 03 Transceiver Unit is an infrared light transmitter and receiver unit Designed for flush mounting ona ceiling it acts like an infrared antenna receiving the signals sent from the Delegate Units and transmitting the signals to the Delegate Units Twenty four transm
3. Power and charging status should be indicated via easily read LED lamps Charger shall be a combination unit that besides battery charging can be used as a storage and transportation solution Battery charger power supply should be safe low voltage DC operation Tray battery charger Close Talk type CH 103 or equivalent 176mm 7 60mm 2 4 300mm 11 8 CTPS 101 is a high capacity power supply designed to provide power to the CH 103 Charger Holder unit At 100W output power it can supply up to eight CH 103 directly Using a sturdy steel box it is intended for quick and safe mounting on the CT 10 trolley frame but can just as easily be used stand alone in applications where the trolley is not needed Completely silent operation using fan less box self ventilation Easy installation with screw less low voltage connectors for up to eight units Easy operation plug in and turn on no settings required 29 Clade lithe CONFERENCE system Data Physical Size WxHxD 300x60x176mm 11 8x2 4x7 Weight 2 2ke 4 8lbs Cable gland Mains power input Electrical for ae voltage ae a Input power output and fuse holder Voltage 100 120VAC or 200 240VAC Internal range selec tion switch Frequency 50 60Hz Power Max 150W Fuse 2AT TIOVAC 1AT 230VAC Output Voltage 9 0 2VDC Current Max 11ADC INSTALLATION GUIDELINES Warning Installation should only be carried out by a qualifi
4. Each charging holder is connected to the power supply at the bottom of the frame using a sim ple low voltage two wire cable Power supply is connected using a regular power cord for easy operation simply plug in to mains power and turn on to start charging Easy to assemble and can be upgraded later with more charger holders Compact design saves storage space 26 Order code CT 10 This order code is for the trolley frame only add one CTPS 101 and one to eight CH 103 per trolley Data Size Width 50mm 29 5 Depth 510mm 24 Height 1210mm 47 6 Weight Frame 12 9kg 28lbs Holder 2 5kg 6lbs Supply 2 2ke 4 8lbs Frame eight holders and a power supply is about 35kg 771bs Twenty four Delegate Units adds 29kg 64lbs resulting in a maxi mum weight of 64kg 141 Ibs Electrical Voltage 100 120VAC 200 240VAC Frequency 50 60Hz Power Max 150W Delegate Unit Battery Charger CH 103 24mm 0 94 720mm 28 4 CH 103 is a fully automatic battery charger for the DU 111 02 Delegate Unit With a three unit capacity and active charging control keeping the Close Talk Conference System ready for action is now easier than ever The CH 103 removes the need to manual ly connect each unit to a charger using a connector simply place the delegate unit in it s holder and charging starts automa tically Charging is actively controlled to minimi ze charging time while preserving maxi mu
5. any time and at the users convenience be expanded in room size more delegate units teleconferencing recording camera follow big screen projection of speaker lists and voting results voting speaker and reply list control attendance management and more there are no future technology dead ends waiting around the corner because of system design decisions today The PC software Close Talk Control has been and still is being developed in close co operation with municipalities and councils to provide the world markets most powerful conference system solution for formal conference and discussion control Being wireless the system provides super flexibility for room re use By using infrared light the system investment has a virtually unlimited in time operational guarantee whereas radio based systems are experiencing increasing problems with ether congestion making Close Talk Conference Systema very good long time investment Basic components for a conference system Delegate Unit DU 111 02 Transceiver TU 100 02 03 or 04 Central Unit CU 110 11 Trolley Charger CT 10 Catalogue Contents J System Introduction pages Describes the system principles product selection installation and usage 1 DU 111 02 Delegate Unit page 7 Updated DU 111 02 Delegate Unit is the main microphone and voting unit There is no special chairman unit in Close Talk Conference System any unit can be chairman via controller programming J CU 110 11 Cen
6. camera follow all pack aged in an easily learned user interface Central Unit Close Talk Control Transceiver Unit Split Box Delegate Unit The delegate unit has an elegant case design suitable for all environments and is very easy to use only two buttons to operate Battery operated with built in speaker several microphone alternatives and headphones output Battery operating time is typically over twenty hours of listen only over eight hours of speaking No special charging arrangements continuous charging supported without degrading the battery Battery is of industry standard type and can easily be replaced in the field Setting up a system is very easy for the end customer simply turn the central unit on place the dele gate units in the room turn them on and start using the system Chairman priority functionality includes speaking channel guarantee and control in several manners to fit all meeting cultures Close Talk Conference System is equally suitable as a ten delegate teleconferencing system as a full 100 large conference room installation 6 EEE Delegate Unit DU 111 02 The DU 111 02 Delegate Unit is a wireless micro phone and voting station with built in speaker and headphones functionality Updated Beginning December 2014 an updated version is shipping with enhanced audio quality The unit uses infrared light as transmission media and has full duplex audio capability The mi
7. independent use by a single person and shall be able to transmit and receive audio in full duplex It shall have a built in speaker and a 3 5mm stereo mini tele connector for optional headphones use The volume levels should be independently presettable for speaker and headphones and the speaker audio should be automatically shut off when a headphone is used The unit should be fully wireless using harmless eavesdrop safe infrared light as transmission media Infra red light is to be transmitted vertically relative to operators position Audio and data is to be transmitted using analog Frequency Modulation and use carrier frequencies in the range 2 to 6MHz and use infrared light with 875nm wavelength The unit power source shall be a rechargeable maintenance free battery of industry standard type and be able to be replaced by the end user The operating time of a fully charged battery shall be minimum 20 hours of listen only and 8 hours of effective speaking time The re charging time of a fully discharged battery shall be no longer than 14 hours A low battery indication shall be included using an LED lamp indicator The unit should power down automa tically 2 minutes after the loss of the main audio carrier Unit type shall be of universal use including built in voting and chairman functionality Unit functionality should be easily upgradeable via wireless firmware updates Operation of the unit shall consist of a clearly organised
8. pre conference security Includes and extends all Central Unit functionality Adds powerful database functionality including delegate and seating lists Speaking time can be limited automatically on individual basis using the delegate list Separate program window displays speaker lists and voting results suitable for video projection Powerful roll call functionality includes traditional roll call and Free Arrival mode Basic functionality easily learned for inexperienced computer user s Included is a basic Agenda manager where the meeting can be structu red Current matter is included in all reports Attendance and Fee management is a function used for creating atten dance reports for conference delegates During a conference tools in the Seating List is used to update the arrival and departure of delegate Each event is noted in the time log After a conference detailed attendance reports can be produced for each seat The attendance data can also be used to produce fee reports for all participating delegates 31 Clade lithe CONFERENCE system EN With a simple mouse click the dele gate units become voting stations Simple vote result selection using single delegate unit button Vote result displays include table time counter bar graph summary and seating view Seating View result display is fully configurable geo placement display using the built in editor Delegate s have individual vote weight including
9. system OO 14 Technical Data Power 10 3 13VDC operation Power consumption 3 6W at12VDC Powered through cable Transmission Broadband receiver and two channel transmitter Receiver frequency range 2 4 5 6MHz infrared light wavelength 875nm Operating range is equipment dependent see diagram on other side Minimum distance to reflective object including a Delegate Unit is two metres vertically Physical EMC shield box size 98x98x60mm wxdxh front plate diameter 150mm Weight approx 0 55kg White steel front plate Flush mounted two spring fastener wall mounting not supported To avoid excessive safety ground currents to enter the system do not connect case to or mount ona grounded surface Environment Indoor home or office use only Temperature 10 35 deg celsius Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only Avoid moisture to enter the unit Approvals CE and FCC approval Order code TU 100 03 Tender Specification The Transceiver Unit is to comply with all relevant CE regulations The unit is intended for vertical transmission and reception of infrared light with an 875nm wavelength Emission power shall be of harmless nature The unit shall transmit two channels and have a broadband receiver for analog FM modulated signals in the 2 6MHZz carrier frequency range The unit shall be connected to the
10. three units per charger It is normally a part of the CT 10 Charger Trolley but can just as easily be mounted on a wall in cupboard ora third party trolley 1 CTPS 101 Battery Charger Power Supply page 29 CTPS 101 Battery Charger Power Supply is a high powered power supply for the CT 10 Charger Trolley CH 103 Tray Battery Charger charger products O Close Talk Control PC software page 31 Close Talk Control is a Windows compatible PC software that greatly expands Close Talk Conference Systems functionality including voting camera follow and much more System Installation Application Note page 33 Updated This application note is an instruction for installing the system J Camera Follow Application Note page 35 Camera follow functionality is implemented via the PC software Close Talk Control as described in this application note 091 1 Language Application Note page 37 Although expands Close Talk Conference System is primarily a single language system it is possible to do 1 1 as described in this application note 4 Clad Vilbe n Introduction to the Close Talk Conference System The Close Talk Conference System is a wireless discussion system based on infrared light transmission which ensures easy installation superior reliability and security The basic system components are the Delegate Unit which is the microphone unit used by the confer ence participants the Central Unit that controls the system functionality the Tr
11. two button operator panel with 4 LED lamps showing power status microphone activity and voting result selection A volume knob should be easily accessible for speaker and headphones level setting The microphone shall contain an LED lamp for activity indication The activation time of the microphone should be less than 1 second using a single button press In the situation of no available speaking channels the unit should clearly indicate that it has been placed in a speaker queue using an LED lamp status indicator The unit shall be able to switch between audio and voting mode without operator assistance The state of voting shall be clearly visible using the status LED lamps Casting a vote should be done using a single or double button operation Delegate Unit model Close Talk type DU 111 02 or equivalent Central Unit CU 110 11 The CU 110 11 Central Unit is a controller unit for Close Talk Conference System Updated Beginning December 2014 an updated version is shipping with enhanced audio quality Acting as the system hub it controls all aspects of the system using microprocessor technology Supports an unlimited number of Delegate Units all units within infrared signal range are operatio nal Up to three simultaneously active microphones Intelligent functionality includes automatic speaker list chairman priority audio level con trol remote controlling and more All functions are easily reached using the 1
12. type settings Begin by selecting the correct serial port number VISCA has preset serial port settings so only the port number is important the other parameters have no effect 35 Clade lithe CONFERENCE system OX Camera configuration _ n met Selecting the VISCA Generic branch will show the VISCA programming and control panel After selecting the correct serial port number connect the cameras to ci Communication VI SCA VISCA 16 an AS 232 seral port camera Ue protocol Fi Sony which is the port and turn them on Wait until the cameras have We Y many MAT achyrers A settled and click the Update button in the Bus control Only the COM port number 18 important fi 4 Th b f d ihe pott ething aie preset bythe group see figure 4 The number of connected cameras standard should be shown within a second at Cameras If not verify port settings cables and cameras and try again The Position entries in the Seating Table must be mat ched to actually programmed positions here Click the New button to start adding positions Besides delegate positions Voting and Neutral can be added where Voting is a position for vote mode and Neutral is the resting Selected system VISCA Generic Disable eae si _ re positions for the camera Use Erase to remove a position Fis 2 Camera configuration vanel use the 1x and 5x to navigate the position list The 1 to 7 G and P buttons are Goto and Program buttons for up to Came
13. 1254 Pre conl active Delegate Volume Mas B S ial a Min Number of speakers Three Speaker te 256 Speaker ket contok Manual 7 Frivi automatic Repl function On Fr Chaman channel Stealchannel Roll call Rod call method F Show eph ist Rec list size 16 Connect unit IL Seat Delegate 1 User One Organisation Apodosis 4B Attendance as Excel Fee as RTF Fee as Excel Line Out Security Attendance Logging Wam at bine beft 00 01 00 Intenupt speaker F Limit reply time Warning sourd Use warming sound Close Function Present Charman Ho Unit D Cancel 1276 Speaker list amp Close Talk Control File Wew Control Help T Ee 284 08 O y 1 Available x 2 Avaliable x 2 Available Avaiatle Reply bist Function Shatak Chaman Orgareration Close Talk Close Talk potoci AB Apodosi AB Mane User Thres Shraetwolden Shane Use Five User Two De ja Le gt hi ee le i ia et gt bi e Ele Manualit 4 delegatefshmspesker ist English Demo Conference tated Yobe about mvestmert proposal System audio settings are easily accessible Fully configurable position and size of all control panels are saved Vital parts of the software such as audio settings can be password protected Delegate unit contact and battery test function for easy
14. 6x2 character LED backlit LC display together witha two button and one rotary knob control panel Unit settings can be PIN code protected Supports up to eight High Frequency signal connections including the TU 100 02 TU 100 03 and TU 100 03 Transceiver Units directly con nected to the CU 110 11 Supports four received channels three audio and one data and two transmitted channels one audio and one data Powered by a safety grounded 12VDC switch mode power supply provides superior reliability and safety World power input range ensures easy installation Sturdy 1U steel case for 19 rack mounting Low power consumption Unit firmware can be easily be updated via the RS 232 serial port Millimeter Mi RS 232 HF signal connectors Fuse RS 232 serial port for remote control applica tions such as Close Talk Control PC software for conference control and Close Talk Install PC software for system testing All connections are easily accessible on the rear panel Rear panel contains 8 HF signal connectors RS 232 serial port system fuse microphone signal insert power input four balanced XLR Line and Tele in and outputs four unbalanced 1 4 Tele Line and Tele in and outputs The number of Transceiver Units can be expanded above eight using the Split Box SB 110 01 or equivalent W006 Vilbe nn 10 Technical Data Audio 200Hz 7500Hz 3dB frequency range S N ratio g
15. Automatic power switching using signal from Central Unit Capabilities Two input and two output ports Controls two systems with automatic port switcthing Acts as a signal amplifier extending the maximum cable length capabilities Outputs can be connected directly to a singe Transceiver Unit but the use of Split Boxes is strongly recommended Physical Size 185x110x28mm wxdxh Weight approx 0 7kg White steel case Four screw fastening To avoid excessive safety ground loop currents do not connect case to or mount ona grounded surface Environment Indoor home or office use only Temperature 0 40 deg celsius Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only Approvals Tender Specification The Switcher Unit is to comply with all relevant CE and FCC regulations The unit should be self powered by the system controller units Switching between system should be automatic and not require any manual operation at the unit Switcher Unit model Close Talk type SU 110 01 or equiva lent Systems are color coded by LED CE and FCC approval The system that is active on the output is indicated by the LED s on the Output ports green or yellow Screw holes for mounting Order code SU 110 01 green for System 1 and yellow for system 2 28 Millimeter Input and Output for system 1 and 2 Installation cables
16. CONFERENCE SYSTEM Wireless Conference System Technology Using Infrared Light In the beginning The history of Close Talk started in Sweden 1988 with a vision of a completely wireless telephone conference system for board rooms and other high end installations The use of radio was quickly discarded and infrared light was chosen as carrier In 1989 the first delivery of this hand made high grade wooden box microphone system was made During the coming five years over 500 units where sold on the Scandinavian market to a wide selection of state municipal and well known local and international companies In 1997 Close Talk decided it was time to introduce it s idea to the world The development of a new generation for the mass market was started to include products and components designed for ease of use quick installation reliability long life and a reasonable price At the turn of the millennium the first generation of this new product line saw the light of day The following two years included a hectic time to build the local Scandinavian market and finally in 2002 generation two was introduced inter nationally at the annual ProLight amp Sound trade show in Frankfurt to intense market interest In 2005 generation three was introduced world wide with a host of new features laying the founda tion for the solid conference technology product range available today Building on a long time of product experience Close Talk Conference Sy
17. STRALIA generally available 24 Order code DC 110 45 Delegate Unit Charger and Transportation Trolley CT 10 CT 10 is a combined battery charger and transpor tation trolley for the DU 111 02 Delegate Unit and can hold up to 24 units The sturdy frame and wheels provides safe transportation and storage Using the CT 10 any conference system size can be setup and removed in minutes The trolley size makes it easy to roll around in the conference room using a suitable wheel size to provide easy passing over thresholds Wheel locks are provided for safe storage 750mm 29 5 TF TTT Oi SO The Delegate Unit holders have built in battery chargers with automatic connection no need for a manual charger cable connector insertion Easy operation simply place the Delegate Unit s in their holders roll the trolley to the storage room and plug it in to mains power Charging is controlled automatically 1210mm 47 6 Each holder has an individual charging status indicator clearly showing the OFF CHARGING and READY states Charging time is typically 10 hours for a fully discharged battery see holder data sheet Units can safely be left in the charger during storage making them ever ready for the longest 510mm 24 of meetings _ Ey 25 CT 10 can be equipped to suit any installation The trolley supports up to eight CH 103 Charger Holders and one CTPS 101 Power Supply which are ordered individually
18. The SB 110 01 Split Box is a one input six outputs High Frequency signal distributor for the Close Talk Conference System The primary function is to expand the number of supported Transceiver Units the distributor input is typically connected to the controller output multiplying the possible number of Transceiver Units by six and the outputs are connected to the Transceiver Units Another important use is to reduce the total cable lengths needed for an installation The Split Box is recommended to be placed as close to the Transceiver Units as possible minimizing their cable segment lengths and making it possible to have only one longer cable running to the control ler The unit is powered by a double isolation ungrounded 12VDC switch mode power supply that provides superior reliability and safety World power input range ensures easy installa tion Power switching is done automatically using a status signal from the controller when the controller shuts down all Split Boxes and Transceiver Units are switched off Split Boxes may be daisy chained in a tree fashion for even greater support of Transceiver Units or to reduce total cable lengths even more Sturdy steel case with four screw fastening Low power consumption produces less heat for easy and safe mounting Connectors are quick connect RJ 45 for fast and trouble free installation Status lamps shows power input and on off state New The Split Box now su
19. able to provide intended functionality without end user assistance The unit shall provide the connection of up to eight High Frequency infrared transmission units The wireless transmission of audio shall be in full duplex using analog FM modulation with carrier frequencies in the 2 to 6MHz range Line level audio in and outputs shall be provided for the transmission of audio to external equipment and the reception of audio from external equipment Balanced audio in and outputs are to be facilitated using industry standard XLR connectors Unbalanced audio in and outputs are to be facilitated using industry standard 1 4 Tele connectors An Insert connector shall be provided for external audio processing of the delegate microphone signal The unit is to be powered by a safe low level direct current voltage using an external power converter with world power input range 100 240VAC System power shall be operated using a single switch on the unit front panel Unit functionality should be easily field upgradeable via firmware updates The unit shall provide an activation time of microphones to be less than 1 second Delegate Unit dependent support up to three simultaneously active microphones provide an automatic first in first out speaker list in the situation of no available speaking channels and provide chairman override functionality By means of a built in RS 232 serial port the system shall be able to be remote c
20. ansceiver Unit which is the infrared transmitter and receiver unit and the Split Box which is used as a signal distributor for easy installation The system has a total of six channels four audio and two data where the Central Unit receives up to three audio and one data and transmits one audio and one data The transceiver units acts as infrared anten nas and are positioned face down on the ceiling Directly below are the delegate units that receives the outgoing audio and data channel When a user wants to speak he presses the microphone activation button and if there is a free audio channel the micro phone will be activated in less than a second if not the unit is placed in an automatic speaking list Fig 1 Transceiver Units positioned in the ceiling The microphone will remain active until the user releases it by pressing the button again A maximum of three microphones can be active atthe same time The transceiver and delegate unit transmits infrared light in a cone shaped form where the transmission effective surface area increases with height up to a limit at about seven metres see unit data sheets for actual data Several transceiver units are used in a grid pattern to provide operation for the required area Fig 2 Delegate Units transmits in the opposite direction Several types of transceiver units are available both for surface and flush mounting The transceivers are connected to the Central Unit usi
21. arely necessary to have complete wall to wall coverage determine the actual operating area and its location Step 3 Use the coverage area diameter and layout all the necessary transceivers and their positions to cover the ope rating area Fig 3 Use the resulting coverage diameter and fill the operating area with the necessary number of transceivers In our example with a ceiling height of 3 5 metres a single line of transceivers will not completely cover the area so a dual row adds plenty of safety margin Fig 4 The Transceivers red are connected to the Split Box yellow using 10 metre cables The cable slack for the two upper Transceivers have been rolled together The Split Box is then connected to the Central Unit blue using another 10 metre cable Ground rule two A cable connected to a Transce iver cannot be longer than 30 metres Ground rule three The cable between a Split Box and the Central Unit cannot be longer than 50 metres T 33 Ground rule four Do not place Transceivers vertically closer to another object including a Delegate Unit than 1 metres Too much IR light intensity will overload the system Ground rule five Transceivers should optimally be mounted face down on the ceiling Mounting the trans ceivers angled is possible but requires some testing Horizontal transmission on wall mounting is not recommended It is strongly recommended to use C
22. atabase and seating arrangements Attendance and fee management shall be implemented Person databases seating arrangements attendance and fee functionality and voting functionality shall all provide detailed mid and post conference report capabilities both in physically printed form and as exported electronic documenta tion Audio system settings and usage system operation status speaker lists shall be easily verified and controlled The Software is to support multiple graphic display outputs for video projection and broadcasting purposes Camera follow functionality is to be provided with multi camera and multi zone programming support Vote result display should include bar graph summary and geo placement display modes Software Close Talk Close Talk Control or equivalent Close Talk Control has three base functions Conference Management Voting and Attendance and Fee Management Conference Management is always included resulting in four available software packages Order Number CTC OPT 1 CTC OPT 2 CTC OPT 3 CTC OPT 4 32 Includes Conference Management Conference Management Voting Conference Management Attendance and Fee Management Conference Management Voting Attendance and Fee Management System Installation Step 1 Determine the actual operating area i e the area where the Delegate Units are used Step 2 Determine the ceiling height at the opera ting area and use a diagram similar to fi
23. crophone amplifier From Controller Line Out Conference system To Controller Line In From Controller HF out of 38 These are the required settings for the Central Unit consult the Central Unit User Manual for a detailed description of each parameter Parameter EO Low EQ High Delegate Volume Line In Line Out Micro Compens Speaker Volume Headphones Vol Setting X Off 36 36 2 x3 y 16 26 Comment Does not affect the delegate unit microphone signal going to the PA no effect Does not affect the delegate unit microphone signal going to the PA no effect Removes the incoming delegate microphone audio from the outgoing audio to the delegate units Recommended setting is for Line Level signals adjust as needed Recommended setting provides Line Level signals adjust as needed If no external feedback destroyer is available adjust as needed With external feedback destroyer set to 203 0 Turns the delegate unit speaker off Sets the delegate unit headphones output level span adjust to the actual headphones used Other Central Unit parameters are not directly related to the 1 1 language configuration consult the user manual and set as required for the desired system operation
24. crophone features include high audio qual ity low noise and variable length Supports four transmitted channels three audio and one data and two received channels one audio and one data Powered by an industry standard lead acid battery ensures fully wireless operation exceptionally long operating time and superior reliability Easy battery handling supports continuous charg ing Simple operation only two buttons No setup required all settings are controlled remotely Simply place the unit within range turn power on and start using Single audio volume knob with individual opera tion for speaker and headphone levels Universal design no special chairman unit or voting station versions Excellent audio characteristics using high quality driver and base reflex box tuning design Unit firmware can be easily be updated via infrared data link The use of infrared light ensures full security from eavesdropping Industry unique variable length microphone suits all users Power amp Speak Buttons Millimeter Variable length 4 microphone IR Transmitter amp Receiver 73 Code Vilbe ooo Technical Data Audio 200Hz 7500Hz 3dB frequency range S N ratio gt 80dB Individual level settings for speaker and headphones Built in high quality polypropylene cone 2 5 speaker 3 5mm stereo mini tele connector for headphones minimum impedance 8 ohms Automatic s
25. d in a grid pattern on the ceiling to cover all common room types Emits safe and harmless infrared light with an 875nm wavelength Standard case colour is white other colours available on request Mounting is by two screws through the back cover Unit is self fastened to the back cover using a screw less snap on grip Opening is easily done with mid size flat nose screw driver Designed for the 2 6MHz signal range makes it insensitive to visible and fluorescent light Connects directly to the Central Unit or via a Split Box Millimeter Receiver RJ 45 connector EMC shield S STP grade cable 5 43 210 1 2 3 4 Smeter Operating range is equipment dependent The figure above shows a radiation diagram together with the DU 111 02 Delegate Unit where the horizontal axis shows radiation diameter at ceiling heights up to seven metres _ EEE 15 Clade lithe CONFERENCE system OO 16 Technical Data Power 10 3 13VDC operation Power consumption 3 6W at 12VDC Powered through cable Transmission Broadband receiver and two channel transmitter Receiver frequency range 2 4 5 6MHz infrared light wavelength 875nm Operating range is equipment dependent see diagram on other side Minimum distance to reflective object including a Delegate Unit is two metres vertically Physical Size 98x98x23mm wxdxh Weight approx 0 33kg White steel case Ceiling surface mounted two screws wal
26. de SB 110 01 2 Tender Specification The Split Box is to comply with all relevant CE regulations The unit shall have one High Frequency signal input and automatically distribute all system signalling to six individual outputs without configuration or user assistan ce The six outputs shall be able to handle one infrared transcei ver unit or be able to connect to another Split Box for expansion purposes The unit is to be powered by a safe low level direct current voltage using an external power converter with world power input range 100 240VAC Unit power shall be controlled automatically by the system controller The unit self heating shall be low enough for safe mounting without special cooling arrangements The unit case shall be of steel white colour and havea four screw mounting method Split Box model Close Talk type SB 110 01 or equivalent Clad llh n Switcher Unit SU 110 01 The SU 110 01 Switcher Unit is designed for automatic switching between two physically adjacent systems e g a room with a removable divider wall where the systems need to be used as two indivi dual systems in separate rooms and as one system in both rooms with very little setup time Two Central Units are required which are connected to the SU 110 01 Central Unit One input and SU 110 01 Central Unit Two input respectively The transceiver section of the area to be controlled by Central Unit One is connected to the SU 110 01 Sy
27. e Talk system or property damage may occur 22 Close Talk Conference System provides six standard cable lengths 5 meter length 10 meter length 15 meter length 20 meter length 30 meter length 50 meter length order code 08 101 05 order code 08 101 10 order code 08 101 15 order code 08 101 20 order code 08 101 30 order code 08 101 50 DC 110 45 is a cost effective battery charger for the DU 111 02 Delegate Unit It supports five units per charger and has fully automatic charging functionality simply plug the charger to the delegate unit charger connector Delegate Unit Charger Connector The DC 110 45 is designed with the standby charging method for Lead Acid battery types This means very long battery life at the expense of charging times which increases slightly a full charge is about 14 hours Using the standby charging method means that the charger can be connected to the delegate units continuously there is no maximum charging time It is recommended to have the charger connected whenever the system is not used providing an ever ready conference system The LED charging indicator is an easy way to check charging status a fully lit LED indicates charging where the brightness slowly decreases to dimmed indicating done The power supply is uses world power voltage range and is ungrounded for easy use in large systems The DC 110 45 battery charger is a very cost effective and easy to use s
28. ed technician improper installation may result in property damage and or personal injury Only mount unit with free ventilation airways leave at least 25mm 1 free air space around unit surfaces Select the correct mains voltage range and input fuses Do not overload the power supply Maintain correct low voltage output polarity Always unplug from mains when opening cover See the CT 10 Installation Manual for more detailed Ventilation Mounting holes information about installation including mounting and inlet outlet for 5mm screws connecting the CH 103 charger holders on top cover Mains voltage range selector Low voltage output fuse Low voltage output connector terminals Mains voltage filter Order code CTPS 101 30 o M Code Vibe Conference Control Software Close Talk Control Close Talk Control is a Microsoft Windows 2000 XP Vista 7 compatible PC software that enhances the Close Talk Conference System with expanded conference control voting attendance and fee management Conference management includes fully controllable Speaker and Reply lists Audio channel usage is easily visible and managed Speaker list size and control fully configu rable No limit to the number of Delegate Units supported Central unit Equalizer Low High Min Min ays Conference Voting Hardware Program Charman unit 1235 Frionty ura 223 Use as platform mic Pre conf unit
29. fractions for share holder meetings Voting period can be timed or operator controlled Vote results can be printed and or exported as RIF document for archiving purposes Close Talk Control gets even more powerful by the addition of camera follow functionality Using the VISCA camera bus control develo ped by SONY any VISCA capable camera can be used Supporting up to seven cameras where each can be programmed for a variety of confe rence events complex video suppor ted conferencing scenarios can be implemented Intelligent camera selection logic makes the best use of available cameras The database functionality makes it easy to store and retrieve multiple conference configurations Close Talk Control is very resource efficient and will run on any modern Personal Computer One RS 232 serial port is required one optional for camera control A second compu ter display output is recommended Matter Investment of eco cars Ti Approve Yes 4 Reject Abstain No Total vote weight Tender Specification The Software is to provide advanced conference control functionality including voting The Software shall be designed to execute on a Personal Computer running any of the Microsoft Windows 2000 XP Vista or7 operating systems Database functionality shall be implemented for easy configuration of multiple conferencing scenarios The database functionality shall include a comprehensive person d
30. gure 2 to get the range diameter 9 4 3 2 1 0 1 2 3 4 5S metre a oe on N O E Fig 2 Use the ceiling height to find the IR signal coverage for a single transceiver for example at 3 5 metres ceiling height the diameter is 6 metres 6x 0 9 is 5 4 metres It is normally enough to connect the area borders when placing the transceivers the area in betwe en will be filled by the co operation of the trans ceivers In our example we have an overlap verti cally but only since two transceivers would not be enough Step 4 We now have the positions for the trans ceivers Determine where the Central Unit and if used the Split Boxes will be placed Ground rule one Each transceiver must have the same cable length with in a one metre margin between the Transceiver and the Central Unit When using Split Boxes sim ply ignore the box and add the length of cable for the Transceiver and the length of the cable betwe en the Split Box and Central Unit When using more than one Split Box in the same room itis only the total length of the cable that mat ter i e if the cables between Split Box 1 and the Transceivers is 5 metres and the cable between Split Box 1 and the Central Unit is 10 metres a to tal cable length of 15 metres the total length for Split Box 2 must be the same but can be a different configuration for example 10 5 metres CONFERENCE SYSTEM Room size 15x10 metres Fig 1 It is r
31. ith two free RS 232 serial ports the Close Talk Control software and one or more cameras The Central Unit is connected to the first serial port on the PC using a null modem cable The cameras are connec ted to the second RS 232 port using an industry standard VISCA to PC serial cable With more than one camera the cameras are daisy chained using a standard VISCA cable see the camera documentation VISCA to PC cable between PC and first camera VISCA daisy chain cable between cameras Null modem cable between PC serial port and controller serial port The following description assumes familiarity with the Close Talk Control software functionality the user manual will provide more Votes unitib Position information Yes 1276 1 Yes 3220 1 E Yes 21581 Added to the Close Talk Control softwares Seating Table is a Position vee sel column Position is simply a list of programmed camera positions Bs PE es 4 connected to one or more Seat Numbers Any Position number can Yes 5677 1 be used one or more times for any Seat Number making it possible to ve a program detailed close ups for each delegate or only a few section ves al shots of the entire conference room Fig 1 Seating Table To program the camera control system start the Camera configuration function on the software main menu The configuration panel con tains two selection trees communication port settings and camera
32. itter LED s are used for two outgoing channels one audio and one data Eight photodetectors converts the received IR signals into an electric signal that is sent to the controller TU 100 03 is connected to the system using an industry standard CAT 6 S STP grade cable with quick connect RJ 45 connectors The unit is self powered via the cable and can accept cable segments of up to 30 metres using a standard AWG26 cable Low power consumption and weight makes safe and easy ceiling positioning easy Several Transceiver Units can be placed in a grid pattern on the ceiling to cover all common room types Emits safe and harmless infrared light with an 875nm wavelength Standard front plate colour is white other colours available at request Mounting is by two springs ideal for false ceiling use cut a square hole connect the cable and slip it in Designed for the 2 6MHz signal range makes it insensitive to visible and fluorescent light Connects directly to the Central Unit or via a Split Box Front diameter Spring fastener 150mm Receiver a ea Transmitter Millimeter Cable inlet 5 3 2 1 0 1 2 3 4 5 meter OO NO oO A W N Operating range is equipment dependent The figure above shows a radiation diagram together with the DU 111 02 Delegate Unit where the horizontal axis shows radiation diameter at ceiling heights up to seven metres D EE 13 Clade lithe CONFERENCE
33. l mounting not supported To avoid excessive safety ground currents to enter the system do not connect case to or mount ona grounded surface Environment Indoor home or office use only Temperature 10 35 deg celsius Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only Avoid moisture to enter the unit Approvals CE and FCC approval Order code TU 100 04 Tender Specification The Transceiver Unit is to comply with all relevant CE regulations The unit is intended for vertical transmission and reception of infrared light with an 875nm wavelength IR emission power shall be of harmless nature The unit shall transmit two channels and have a broadband receiver for analog FM modulated signals in the 2 6MHZz carrier frequency range The unit shall be connected to the system using industry standard CAT 6 S STP grade network cables Operating power shall be provided via the cable at up 30 metre segment lengths The unit shall be mounted face down on a ceiling surface using two screw for fastening Operating power voltage levels and power consumption shall provide for safe mounting without special cooling arrangements The unit is to be of square case design Case material is to be steel and be of white colour At request other colours can be provided Transceiver Unit model Close Talk type TU 100 04 or equivalent Split Box SB 110 01
34. lk Control to use camera control click the Select button and close the Camera configuration panel When starting the conference the selected sys Camera usage mode Eae c tem type will be initialized To disable camera follow Rs ne pane click the Disable button figure 3 D Maximize usage Selected system VISCA Generic Select Fig 4 VISCA programming panel 36 ha 1 1 Language application Although Close Talk Conference System is a single channel conference system it is still possible to use for dual language applications By breaking the signal path for the incoming delegate unit microphone audio and instead sending it via the controller Line Out to an external PA the conference system out going audio is freed for an additional language The PA audio is also routed to the interpreter booth headphone amplifier which means the interpreter will only hear what is spoken into the delegate unit microphones The amplified interpreter microphone signal is connected to the controller Line In port The delegate unit speaker audio is turned off and the headphones signal is set to a comfortable range where the delegates can set their own level using the delegate unit volume knob Each delegate unit is equipped with a headphone where the delegates listen to their own language using the PA and use the headphones for the second language Conference room PA Delegate Unit microphone audio Interpreter booth headphone and mi
35. lose Talk Conference System cables they are ready made cables in lengths of 5 10 15 20 30 and 50 meters which enables quick and problem free installation Close Talk Conference System is designed for and all its certifications are based on the use of the ISO IEC 11801 in dustry standard Cat 6 S FTP grade Ethernet cable type The S FTP formerly known as S STP grade means double shielding i e all four signal pairs have an individual shield and then the four pairs have a common outer shield Do not use UTP FTP or STP grade cables it may cause system stability pro blems and will void system warranty Itis also possible to use custom built cables but please note e Always use Cat 6 S FTP S STP cables e Use shielded connectors e Always test the cable before connecting it to any Close Talk products a faulty cable may cause product damage not covered by warranty e When using RJ 45 Cable Joiners Extenders use a shielded type e Use the industry standard straight RJ 45 Ethernet patch cable pin out e Faulty custom built cables either from using the wrong components or by poor manufacturing may seriously compromise the system stability and its protection against eavesdropping e Roll up cable slack using bow ribbon shape not a coil e Minimum cable bending radius is 30mm lower than that may damage the cable and cause system instability Important Close Talk Conference System uses proprietary signaling not Ethernet Only connect Clo
36. m battery life and is designed for stand by use supporting continuous charging Three unit capacity Charging status indicators shows the OFF CHARGING and DONE states When charging is ready simply lift the unit out of it s holder and start using CH 103 is powered by the CTPS 101 power sup ply using simple quick connect cable terminals Although primarily designed for use with the CT 10 Charger Trolley the unit can just as easily be mounted ona shelve a wall etc using the supplied brackets Power and charging status indicators gt 27 Mounting bracket kit Code talk o oo 28 Mounting holes __ K for 8mm screws 710mm 27 95 Power input connectors Bracket mounting Technical Data Physical Size WxHxD 720x24x142mm 28 4x0 94x5 6 Weight 2 5kg 5 5lbs Colour Black Electrical Supply voltage 9 0 2VDC Supply current Max 1 25ADC Charging current Max 0 38 0 02ADC Charging voltage 6 8 0 1VDC Order code CH 103 This order code is the tray charger only add a CTPS 101 as power supply Each power supply supports up to eight CH 103 Power input connection Tender Specification The battery charger should be designed for Lead Acid battery type Charging method should be according to the stand by method to maximize battery life The battery charging cycle shall be fully automatic and not require any operator assistance other than initial unit seating
37. nal range makes it insensitive to visible and fluorescent light Connects directly to the Central Unit or via a Split Box Transmitter 12 112 Millimeter Front diameter 180mm RJ 45 connector EMC shield S STP grade cable 1 2 3 4 9 meter 10 Operating range is equipment dependent The figure above shows a radiation diagram together with the DU 111 02 Delegate Unit where the horizontal axis shows radiation diameter at ceiling heights up to seven metres D 11 Clade lathe CONFERENCE system 6 12 Technical Data Power 10 3 13VDC operation Power consumption 3 6W at 12VDC Powered through cable Transmission Broadband receiver and two channel transmitter Receiver frequency range 2 4 5 6MHz infrared light wavelength 875nm Operating range is equipment dependent see diagram on other side Minimum distance to reflective object including a Delegate Unit is two metres vertically Physical EMC shield box size 92x92x8mm wxdxh front plate diameter 180mm Weight approx 0 32kg White steel front plate Flush mounted four screws fastener wall mounting not supported To avoid excessive safety ground currents to enter the system do not connect case to or mount ona grounded surface Environment Indoor home or office use only Temperature 10 35 deg celsius Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only
38. ne or more DU 111 02 Delegate Unit usu ally one per conference participant one CU 110 11 Central Unit which is the system controller a num ber of TU 100 xx Transceiver Unit where the required number depends on the required room usage area of the system a battery charger solution for the delegate units and finally some cables to connect the transceiver units to the central unit The delegate unit is a battery powered all inclusive unit there are no special models for chairman voting etc The system supports unlimited delegate units with a limit of three active microphones A central unit acts as the controller of the system with built in automatic speaker queue and more Transceivers acts as transmitter receiver antennas for the IR signals and are connected to the central unit using RJ 45 Cat 6 cables The central unit supports up to eight direct connected transceivers supporting the most common installation sizes For larger installations or with complex cabling an SB 110 01 Split Box is available that acts as a one to six port expander Two battery charger solutions are available for the delegate units the low cost DC 110 45 Cord Battery Charger and the CT 10 Trolley Charger that besides battery charging also provides a very convenient transportation and storage functionality Close Talk Conference System deluxe Close Talk Conference System is a completely modular conference system the basic audio only system described above can at
39. ng Cat 6 S STP grade RJ 45 cables for easy installation While the central unit can accept up to eight directly connected transceiver units a Split Box can be used to expand that number Another important use for the split box is to reduce the cable lengths in an installation running a lot of cables from a ceiling down to a technical room where the central unit is usually placed is impractical and expensive The split box is placed as close to the transceiver units as possible reducing the num ber of cables needed for the central unit _ EEE 5 Clade lithe CONFERENCE system DD DD iii _ The central unit is a microprocessor based control unit for the system It provides the basic conference system functionality such as audio channel management speaker list and chairman override without operator assistance In addition it has an extensive set of audio in and out connections microphone insert HF infrastructure connectors and RS 232 serial port A clean and easy to use front panel makes it very simple to access the settings The unit functionality can easily be upgraded on the field via firmware upgrade The unit also has an extensive control command set via RS 232 for system testing and remote controlling applications Close Talk Control is a powerful PC software that via the RS 232 port expands the system dramatically to provide the tools for professional conferencing including voting speaker lists advanced database technology and
40. olution for a more powerful charging and transportation solution the CT 10 Charger Trolley is available please see separate data sheet O EEE 23 Clade lithe CONFERENCE system Technical Data Physical Size Box WxHxD 80x55x25mm Size Power Supply WxHxD 95x45x30mm Total Weight 0 4kg Cable length PS gt Charger Box 170cm Cable lengths Charger Box gt DU 45cm Electrical Voltage 100 240VAC Automatic range selection Frequency 50 60Hz Power Max 30W Mains plug Ungrounded double isolation Indication Green LED for power on Charging Method Fully automatic standby Lead Acid charging Charging time Max 14 hours Indication Five red LED indicators Tender Specification The battery charger should be designed for Lead Acid battery type Charging method should be according to the stand by method to maximize battery life The battery charging cycle shall be fully automatic and not require any operator assistance other than initial cable connections Power and charging status should be indicated via easily read LED lamps Charger should support a minimum of five target units per charger Battery charger power supply should be of ungroun ded double isolation type have world power range input of at least 100 240VAC and support both 50 and 60Hz power frequency Battery charger Close Talk type DC 110 45 or equiva lent Please specify mains plug type when ordering EU USA UK and CHINA AU
41. ontrolled in all major aspects of the system functionality Audio feedback reduction functionality shall be built in The unit case shall be of steel black color and suitable for standard 19 rack mounting Central Unit model Close Talk type CU 110 11 or equiva lent A006 Wilt Transceiver Unit TU 100 02 The TU 100 02 Transceiver Unit is an infrared light Receiver transmitter and receiver unit Designed for ceiling flush mounting it acts like an infrared antenna receiving the signals sent from the Delegate Units and transmitting the signals to the Delegate Units Twenty four transmitter LED s are used for two outgoing channels one audio and one data Eight photodetectors converts the received IR signals into an electric signal that is sent to the controller TU 100 02 is connected to the system using an indu stry standard CAT 6 S STP grade cable with quick connect RJ 45 connectors The unit is self powered via the cable and can accept cable segments of up to 30 metres Low power consumption and weight makes safe and easy ceiling positioning easy Several Transceiver Units can be placed in a grid pattern on the ceiling to cover all common room types Emits safe and harmless infrared light with an 875nm wavelength Standard front plate colour is white other colours available on special order Mounting is by four screws standard BOSE ceiling speaker pattern Designed for the 2 6MHz sig
42. peaker shut off when inserting headphone Power Built in 6 volt 3 2Ah lead acid battery Industry standard battery type Battery easily replaced does not require return to factory Operating time fully charged 20 hours listen only 8 hours effective speaking time Estimated battery life greater than 5 years in normal use Charging time fully discharged 10 14 hours Fully automatic charging Continuous charging without battery degradation Transmission Fully wireless operation using infrared light Vertical transmission 6channels four transmitted and two received Frequency range 2 4 5 6MHz IR wavelength 875nm Insensitive to visual light including fluorescent Analog FM modulation Audio channel S N ratio 60dB companded to greater than 80dB Data channel bit phase modulated 1 67kb s Physical Size 205x125x73mm wxdxh Weight approx 1 2kg Grey plastic case Microphone length 270 480mm Environment Indoor home or office use only Temperature 10 35 deg celsius Battery contains lead recycle according to local laws and regulations Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only Approvals CE and FCC approval Unit emits safe and harmless infrared light Order code DU 111 02 Tender Specification The Delegate Unit is to comply with all relevant CE regulations The unit is to be designed for
43. pports having Transceivers directly connected to the Central Unit in parallel with the Split Box add 5 meter cable length per Split Box for directly connected transceivers A006 Wilt Millimeter 110 Six HF signal outputs Screw holes for mounting HF signal input with Status lamps S STP grade cable Power supply input O EEE 17 Clade lithe CONFERENCE system OO 18 Technical Data Power 11 13VDC operation 12VDC nominal World power range 100 240VAC input power supply Power consumption 6W no transceivers connected Power supply supports up to six directly connected Transceiver Units type dependent Automatic power switching using signal from controller Capabilities One input port six output ports distributor Input can be connected to controller or daisy chained with other Split Boxes Outputs can be connected directly to Transceiver Units or daisy chained with other Split Boxes Physical Size 185x110x28mm wxdxh Weight approx 0 7kg White steel case Four screw fastening To avoid excessive safety ground loop currents do not connect case to or mount ona grounded surface Do not use a safety grounded power supply Environment Indoor home or office use only Temperature 10 35 deg celsius Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only Approvals CE and FCC approval Order co
44. ra configuration Fo o mS seven cameras Click the P button to program the posi Communication Select COM port number and tion for the corresponding camera number The camera eu state is stored in the position number type shown at Position Click G to send the corresponding camera to the programmed position Click Shift P to delete a specific cameras position The PSpeed and TSpeed set tings are the Pan Speed and Tilt Speed for the cameras Different camera types accepts different speeds if the camera misbehaves after changing these two settings reduce it until the camera responds or verify the setting with the camera specifications Camera selects the current camera to be controlled Click Lft Rgt Up Dwn to pan and tilt in single steps use Shift Click to move in OM gt Port available Selected system VISCA Generic sa multiples of 10 Control Click to move in steps of 100 and Shift Control Click to move in steps of 1000 The In Fig 3 Serial port selection and Out buttons control zoom use Shift Click to move in larger steps Be patient with the movement controls let the camera move in its own pace following the linet ue progress on a video monitor Bus control c ap Time amers To Neutral Update 0 eee Several methods of camera handling are available Position including Exclusive camera Most recent microphone and 7 Maximize usage Camera configuration 2 El Communication To configure Close Ta
45. se Talk equip ment to a Close Talk system or property damage may occur After connecting the components the system is ready for power on When turning on the system pay attention to the power lights on the Central Unit and Split Boxes they should all be brightly lit Use the analyser software Close Talk Install freely downloadable from www closetalk se to test the IR signal coverage When the IR signals are considered OK the system can then be tuned using the Central Unit settings as described in the supplied Central Unit User Manual It can also be downloaded from www closetalk se Important This document is a quick introduction to the system installation principles Always consult the full product documentation such as product manuals and web site before making an actual installation 34 Clad llh n Camera Follow An introduction Camera follow is implemented in the Close Talk Conference System via the PC software Close Talk Control With its powerful database functionality it provides easy configuration of the system for a variety of applications The camera follow functionality is based on the VISCA camera control bus protocol from SONY enabling any VISCA capable camera to be used Up to seven cameras can be controlled for maximum flexibility where each can be programmed for specific events during the conference To start using camera follow with the Close Talk Conference System all that is needed is a regular PC w
46. stem One output and the second area is connected to the SU 110 01 System Two output Although it is possible to connect a Transceiver Unit directly to the Switcher Unit outputs itis strongly recommended to use a Split Box to connect the transceivers With both Central Units turned on the two systems works independently Turning off either Central Unit connects the transceivers from both areas to the remaining active Central Unit Any of the two Central Units can be shut down making special applications possible using different Central Unit setups The SU 110 01 Switcher Unitis self powered by the Central Units via the signal cables The Switcher Unit is also parallel capable i e Transceivers can be connected directly to the Central Unit in parallel with the Switcher Unit node if the cabling is planned correctly Similar to the Split Box the Switcher Unit adds or is equivalent to 5 meters of cable which means that cables for directly connected equipment in parallel with the Swicther Unit should be 5 meters longer totally Switcher Unit SCEN System Two Split Box Two lt Max 30 meters gt Max 50 meters System One Central Unit One Central Unit Two Split Box One PE Code talk n Technical Data Power 11 13VDC operation 12VDC nominal Powered by the Central Units no external power supply needed Power consumption 3W no outputs connected 3 8W one output connected and4 3W both outputs connected
47. stem will continue towards the goal of becoming the worlds most price worthy wireless conference and voting system Project history and market impact Close Talk Conference System has been sold in many thousands of units to numerous prestigious custom ers such as presidential and governmental offices United Nations World Bank US Senate numerous municipalities and corporations all over the world Key features highly appreciated by the customers are ease of installation ease of use excellent design excellent reliability total safety to eavesdropping and excellent value for money Company information Close Talk Conference System is owned and run by the Swedish company Apodosis AB that handles product development marketing and production The system is fully produced in Sweden using local subcontractors Visit us at www closetalk se e mail us at sales closetalk se or call us at 46 0 8 7645227 Copyright 2012 2015 Close Talk Conference System Apodosis AB Sweden All rights reserved All copying either in whole or in part by any means of this document for any purposes or use other than to promote Close Talk Conference System is strictly prohibited For best results this document is supposed to be printed dual sided Documentversion 5 Released 2015 March 22 All specifications subject to change without prior notice 2 o EEE The Close Talk Conference System A basic audio only Close Talk Conference System consists of o
48. system using industry standard CAT 6 S STP grade network cables Operating power shall be provided via the cable at up 30 metre segment lengths Operating power voltage levels and power consumption shall provide for safe mounting without special cooling arrangements The unit shall be flush mounted face down on a ceiling using two springs for fastening The unit is to be of round front plate design Front plate material is to be steel and be of white colour At request other colours can be provided Transceiver Unit model Close Talk type TU 100 03 or equivalent A006 Ville Transceiver Unit TU 100 04 The TU 100 04 Transceiver Unit is an infrared light transmitter and receiver unit Designed for ceiling surface mounting it acts like an infrared antenna receiving the signals sent from the Delegate Units and transmitting the signals to the Delegate Units Twenty four transmitter LED s are used for two outgoing channels one audio and one data Eight photodetectors converts the received IR signals into an electric signal that is sent to the controller TU 100 04 is connected to the system using an industry standard CAT 6 S STP grade cable with quick connect RJ 45 connectors The unit is self powered via the cable and can accept cable segments of up to 30 metres using a standard AWG26 cable Low power consumption and weight makes safe and easy ceiling positioning easy Several Transceiver Units can be place
49. t 80dB Equalizer for Delegate Unit microphone signal Insert connector for Delegate Unit microphone signal Balanced and unbalanced Line and Tele audio connectors Power 12VDC operation World power range 100 240VAC input power supply Power consumption 11W no transceivers connected Power supply supports up to eight directly connected Transceiver Units type dependent Front panel system power switch Transmission 6channels four received and two transmitted Frequency range 2 4 5 6MHz Analog FM modulation Audio channelS N ratio 60dB companded to greater than 80dB Data channel bit phase modulated 1 67kb s Physical Size 480x281x44mm wxdxh Weight approx 4 5kg Black steel case 1U 19 rack mounting Environment Indoor home or office use only Temperature 10 35 deg celsius Recycle case and contents according to local laws and regulations Clean using soap water damped cloth only Approvals CE and FCC approval Order code CU 110 11 Tender Specification The Central Unit is to comply with all relevant CE regula tions The configuration of the unit shall be facilitated by an easily readable LC display and status lamps The display shall be backlit An easy to use two button and rotary switch panel provides access to the unit The unit configuration shall be able to protect using a PIN code With proper installation configuration the unit shall be
50. tral Unit page 9 Updated CU 110 11 Central Unit is the main system controller The built in microprocessor controls the entire system including an RS 232 port for remote control applications O TU 100 02 Transceiver Unit page 11 A Transceiver Unit acts as the system antenna The TU 100 02 Transceiver Unit is for flush mounting using a BOSE ceiling speaker mounting pattern O TU 100 03 Transceiver Unit page 13 TU 100 03 Transceiver Unit is for flush mounting using spring fastener suitable for false ceilings 1 TU 100 04 Transceiver Unit page 15 TU 100 04 Transceiver Unit is suitable for surface mounting O SB 110 01 2 Split Box page 17 Updated SB 110 01 2 Split Box is used to expand the number of supported system transceivers O SU 110 01 Switcher Unit page 19 New SU 110 01 Switcher Unit provides automatic switching of adjacently installed systems O Cables page 21 Installation cables for the Transceiver units O DC 110 45 Cord Battery Charger page 23 DC 110 45 Cord Battery Charger is a low cost battery charger for the DU 111 02 Delegate Unit and supports five units per charger O CT 10 Charger Trolley page 25 CT 10 Charger Trolley is a combined battery charger transportation and storage trolley for the DU 111 02 Delegate Unit and supports up to twenty four units per trolley 1 CH 103 Tray Battery Charger page 27 CH 103 Tray Battery Charger is a fully automatic battery charger for the DU 111 02 Delegate Unit and supports
Download Pdf Manuals
Related Search
Related Contents
gentleMACS™ Dissociator - QB3 Samsung W/W Laser MFP SCX-4200 取扱説明書印刷はコチラ Graco 3A0537G User's Manual Simidur Press X - Wieland Dental END USER GUIDE Istruzioni per l`uso 2013 Accord Nouvelles sur la réparation des - Techinfo Mode d'emploi Copyright © All rights reserved.