For your own safety, please read this user manual carefully before
Contents
1. I E y An Pan Reverse With this function you can reverse the Pan movement 1 Select RPAN by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or press DOWN button to OFF if you don t 4 Press ENTER to confirm or Press MODE ESC to return to the main menu In 1 bb 1 Switch 16 bit 8 bit With this function you can switch the device from 16 bit to 8 bit resolution 1 Select 16BT by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or press DOWN button to OFF if you don t 4 Press ENTER to confirm or Press MODE ESC to return to the main menu LILI Pan degree select With this function you can select pan angle 630 or 540 1 Select DEGR by pressing UP or DOWN button 2 Press ENTER the display shows 630 or 540 3 Press UP or DOWN button to select 630 or 540 4 Press ENTER to confirm or Press MODE ESC to return to the main menu 5 P E E Pan Tilt speed mode select With this function you can select Pan Tilt speed mode Select SPEE sing LOW or HIGH button Press ENTER the display shows LOW or HIGH Press UP or DOWN button to select LOW or HIGH Press ENTER to confirm or Press
2. A lt z O N N LL LL O Q A DESIGN PROMO 360 USER MANUAL KEEP THIS MANUAL FOR FUTURE NEEDS For your own safety please read this user manual carefully before installing the device CAUTION Keep this device away from rain and moisture CAUTION Unplug mains lead before opening the housing Every person involved with the installation operation and maintenance of this device has to be qualified follow carefully the instructions of this manual INTRODUCTION Thank you for having chosen this professional advertisement lighting You will see you have acquired a powerful and versatile device Unpack the device Inside the box you should find 1 The fixture device 2 A power cable 3 An XLR connection cable 4 Asafety cable and this manual Please check carefully that there is no damage caused by transportation Should there be any consult your dealer and don t install this device Features 16 bit resolution Movement 540 630 optional For smooth and precise resolution Can rotate continuously While Channel 4 on DMX value 0 63 channel 1 2 3 can do 16 bit high resolution movement While Channel 4 on DMX value 64 127 the base rotates continuously in clockwise direction While Channel 4 on DMX value 128 191 the base rotated continuously in counterclockwise direction While Channel 4 on DMX value 236 245 reset after 8 seconds SAFETY INSTRUCTIONS CAUTION Becareful with your oper
3. JUDO Program Run JFF 1 Select REC by pressing UP or DOWN button LINE EDO 2 Press ENTER the display shows RE XX XX stangs for ILIE ee the number from 1 to 400 999 3 Press ENTER to confirm or Press MODE ESC to return to n OOF the main menu crys a LU 1 Editing the channels of the individual scenes With this function you can edit the program to be called up in Run a Editing via the Control Board 1 Select SC01 by pressing UP or DOWN button 2 Press ENTER the display shows SCXX X stands for the scene no to be edited 3 Change the scene no by pressing UP or DOWN button 4 Press ENTER the display shows C X X stands for the channel no Such as C 01 it means you are editing channel 1 of the selected scene 5 Select the channel no you would like to edit by pressing UP or DOWN button 6 Press ENTER to enter editing for the selected channel the fixture reacts to your settings The display shows the DMX value of the edited channel Such as 11 XX it stands for in the channel 11 of the editing scene the DMX value is XX XX is a hexadecimal number value 01 FF 7 Adjust the desired DMX value by pressing UP or DOWN button 8 Press ENTER in order to edit other channels of this scene 9 Repeat steps 5 9 until you finish setting all the DMX values for all channels of this sc
4. A Restore factory settings With this function you can restore the factory settings of the device All settings will be set back to the default values shaded Any edited scenes will be lost 1 Select LODA by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or press DOWN button to OFF if you don t 4 Press ENTER to confirm or Press MODE ESC to return to the main menu LIE Software version With this function you can display the software version of the device 1 Select VER by pressing UP or DOWN button 2 Press ENTER the display shows V X X X X stands for the version number e g V 1 0 V 2 6 3 Press MODE ESC to return to the main menu Fr ZJ m Main menu 2 E E MAE CLME 1 Press MODE ESC to enter the main menu display flashing 2 Press UP or DOWN button to select TIME MAL l Fixture running time With this function you can display the running time of the device 1 Select MATT by pressing UP or DOWN button 2 Press ENTER the display shows XXXX X stands for the number of hours 3 Press ENTER to confirm or Press MODE ESC to return to the main menu FT i ZJ 3 co mT Te 00 XM080 V1 0 NR EL ME Clear fixture time With this fun
5. Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually CAUTION Never touch the device during operation The housing may heat up Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals GENERAL GUIDELINES This device is a lighting effect for professional use on stages in discotheques theatres etc This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual the device was designed for indoor use only Lighting effects are not designed for permanent operation Consistent operation breaks may ensure that the device will serve you for a long time without defects Do not shake the device Avoid brute force when installing or operating the device While choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust The minimum distance between light output from the projector Always fix the fixture with an appropriate safety cable if you use the clamp to hang up the fixture When fixing the device on a raised from the ground support be sure to use no less than screws and nuts of M10 x 25 mm and insert
6. them in the pre arranged screw holes in the base of the fixture If you use the quick lock cam in hanging up the fixture please make sure the 4 quick lock fasteners turned in the quick lock holes correctly Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional 0 XMO080 V1 0 NR operation Please use the original packaging if the device is to be transported For safety reasons please be aware that all modifications on the device are forbidden If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to short circuit burns electric shock lamp explosion crash etc INSTALLATION INSTRUCTIONS Mounting the device CAUTION Please consider the EN 60598 2 17 and the other respective national norms during the installation The installation must only be carried out by a qualified person The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture The operator has to make
7. 00 AN gt PINO ES ES j E U ae 0 Que j QUe Y 7 QQe ie id i Va a al J dnc 120 Ohms DMX 512 Controller lt lt lt N address 9 address 5 address 1 Projector DMX starting address selection All fixtures should be given a DMX starting address when using a DMX signal so that the correct fixture responds to the correct control signals This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device You can set the same starting address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to listen to the same control signal from the same channel number In other words changing the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected fixture In the case of the ad lighting which is a 4 channel fixture you should set the starting address of the first unit to 1 the second unit to 5 4 1 the third unit to 9 5 4 a
8. MODE ESC to return to the main menu UD NIF 1I I I Mic sensitivity With this function you can adjust the sensitivity of the microphone 1 Select MIC by pressing UP or DOWN button 2 Press ENTER the display shows M XX XX stands for the number from 0 to 99 M 70 is defaulted value 3 Press ENTER to confirm or Press MODE ESCT to return to the main menu A LEL Automatic Run by no DMX With this function you can automatic run the device by no DMX 00 XM080 V1 0 NR Select AUTO by pressing UP or DOWN button Press ENTER the display shows ON or OFF Press UP to select ON if you wish to enable this function or OFF if you don t Press ENTER to confirm or Press MODE ESC to return to the main menu AO co 5 HAY Sound Run by no DMX With this function you can sound run the device by no DMX 1 Select SOUN by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or OFF if you don t 4 Press ENTER to confirm or Press MODE ESC to return to the main menu FESE Reset With this function you can Reset the device via the Control Board 1 Select REST by pressing UP or DOWN button 2 Press ENTER to confirm or Press MODE ESC to return to the main menu IIi L Ud
9. ations W ith a dangerous voltage you can Suffer a dangerous electric shock when touching wires This device has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual 0 XMO080 V1 0 NR I Important Damages caused by the disregard of this user manual are not subject fo warranty The dealer wil nat accepi abilty for any resulting defects or problema If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature If the external flexible cable or cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard This device falls under protection class I Therefore it is essential that the device be earthed The electric connection must carry out by qualified person Make sure that the available voltage is not higher than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it
10. ction you can clear the running time of the device 1 Select CLMT by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or press DOWN button to OFF if you don t 4 Press ENTER to confirm or Press MODE ESC to return to the main menu Z Eg iE Main menu 3 Ed It StEP S 0 1 5 40 1 Press MODE ESC to enter the main menu display flashing Ta en 2 Press UP or DOWN button to select EDIT re FE ii CANF 0 1007 SLO I L 0 I G 100 SEEP pen g O IFE Define the number of steps in Run l With this function you can define the number of steps in the Program C 30 3000 Run 30 F 1 Select STEP by pressing UP or DOWN button 2 Press ENTER the display shows S XX X stands ENINEJED for the total amount of steps you want to save so you can z call up to 48 scenes in RUN For example if the XX is 05 it 939 means that RUN will run the first 5 scenes you saved in EDIT cn n A DEF 3 Press ENTER to confirm or Press MODE ESC to return to the main menu SC 4g E 0 1 0100 D IFF rel Auto Save Tan With this function you can automatic save the number of steps in the L 30
11. d the scenes can be called up under RUN CRADARWNE INSTRUCTIONS ON USE DMX channel s functions and their values 4 DMX channels Channel 1 PAN movement 8bit Channel 2 Pan fine 16bit Channel 3 Speed pan movement 0 255 PAN max to min speed Channel 4_ PAN Function 0 63 Normal 64 127 forwards Pan rotation from 128 191 Backwards Pan rotation 192 235 no function 236 245 Motor reset 246 255 no function O0 XMO080 V1 0 NR ERROR CODES When power is applied the unit will automatically enter reset test mode This mode brings all the internal motors to a home position If there is an internal problem with one or more of the motors an error code will flash in the display in the form of XXer were as XX will represent a function number For example when the display shows 05Er it means there is some type of error with the channel 5 motor If there are multiple errors during the start up process they will all flash in the display For example if the fixtures has errors on channel 1 channel 1 and channel 1 all at the same time you will see the error message 01Er 02Er and 03Er flash repeated 5 times If an error does occur during the initial start upprocedure the fixture will self generate a second reset signal and try to realign all the motors and correct the errors if the error persist after a second attempt a third attempt will be made If after a third attempt all th
12. e errors have not been corrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand by mode until subsequent repairs can be made 2 Less than 3 errors The fixture has less than 3 errors therefore most other functions will work properly The fixture will attempt to operate normally until the errors can be correct by a technician The errors in question will remain flashing in the display as a reminder of internal errors 01 Er pan movement wheel error The pan movement wheel is not located in the default position after start upor after a reset command This message will appear after a fixture reset if the pan movement wheel s magnetic indexing circuit malfunctions sensor failed or magnet is missing or there is a stepper motor failure defective motor or a defective motor IC drive on the main PCB CLEANING AND MAINTENANCE The following points have to be considered during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 1 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 2 The electric power supply cables must not show any damage ma
13. ene 10 Once all the channels completed the display will flash TIME 11 Press ENTER to edit the time needed the display shows TXXX XXX stands for the time needed to run the current scene value 001 999 E g 002 means you need 0 4ms 002 0 2ms to run the current scene O0 XMO080 V1 0 NR 12 Adjust the desired time by pressing UP or DOWN button 13 Press ENTER to save the settings for the scene you are editing the display will change to the next scene automatically 14 Repeat step 3 14 to edit and other scenes you can edit and save a maximum of 48 scenes 15 Press MODE ESC to exit The number of steps can be defined under STEP and the scenes can be called up under RUN b Editing via the external controller Call up the first scene in your controller now Select SC01 by pressing UP or DOWN button Press ENTER the display shows SCO01 Press ENTER the display shows C 01 Select CNIN by pressing UP or DOWN button Press ENTER the display shows OFF Press UP or DOWN button the display shows ON Press ENTER the display shows SC02 You successfully downloaded the first scene Adjust the Step time as described above under point 12 Call up the second scene in your controller now 10 Repeat steps 5 11 until all desired scenes are downloaded 11 Press MODE ESC to exit The number of steps can be defined under STEP an
14. es on the bottom of the device Tighten the quick lock fasteners fully clockwise Install the second Omega holder Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the ad lighting You can chain multiple ad lighting together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX output DMX input XLR mounting sockat XLR mounting sockat 1 Ground 1 Ground Sd 2 Signal 2 Signal 3 Signal 3 Signal DMX 512 connection with DMX terminator e XM080 V1 0 NR For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 12
15. n Lamp can be turned on via DMX controller XMO080 V1 0 NR Main functions EE E mE fido rn oO nr Lr AAC OE Main menu 0 1 Press MODE ESC to enter the main menu MODE display flashing 2 Press ENTER and select ADDR RUN or DISP by pressing UP or DOWN button 3 Press ENTER for selecting the desired sub menu nOdE lBadr cun d ISP A 1 OC C DMX address setting Slave setting MOdE Addd LALU AOD A51 1 SL AU Dn 0FF HALL i DMX address setting With this function you can adjust the desired DMX address via the Control Board 1 Select VALU by pressing UP or DOWN button 2 Press ENTER the display shows AXXX XXX stands for the DMX address from 001 to 511 3 adjust the DMX address by pressing UP or DOWN button 4 Press ENTER to confirm or pressing MODE ESC to return to main menu 75 5 l AL Slave setting With this function you can define the device as slave Select SLAV by pressing UP or DOWN button Press ENTER the display shows ON or OFF Press UP to select ON if you wish to enable this function or press DOWN to select OFF if you don t Press ENTER to confirm or press MODE ESC to return to main menu PR Fr Li n Program Run Master setting With the function RUN yo
16. nd so on 0 XM080 V1 0 NR Note The modes of DMX 512 data and lamp are shown via the display ADOS ADO AO AGOI DMX OK AA NO DMX loe Lamp on Lamp on Lamp off Lamp off 1 After switching on the device will automatically detect whether DMX 512 data is received or not If the data is received the the display will show A 001 with the actually set address If there is no data received at the DMX input the display will flash A001 with the actually set address This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the device the controller is switched off or defective if the cable or connector is defective or the signal wires are swap in the input connector It s necessary to insert the XLR termination plug with 120 Ohm in the last lighting in the link in order to ensure proper transmission on the DMX data link 2 If the lamp is on the the display will show A00 1 with the actually set address If the lamp is off the the display will show A001 with the actually set address 0 XMO080 V1 0 NR Control Board The Control Board offers several features you can simply set the starting address switch on and off the lamp run the pre programmed program or make a reset The main menu is accessed by pressing the Mode esc button until the display starts flashing Browse through the menu by pressing the Up button or Down button Press the Enter bu
17. only show the DMX value of the 14 channel Press ENTER to confirm or Press MODE ESC to return to the main menu __ Jo ro 15 Reverse display With this function you can rotate the display by 180 l 2 3 4 Select RDIS by pressing UP or DOWN button Press ENTER the display shows ON or OFF Press UP to select ON if you wish to enable this function or press DOWN button to OFF if you don t the display will rotate by 180 Press ENTER to confirm or Press MODE ESC to return to the main menu Fr 1 Cid i Shut off LED display With this function you can shut off the LED display after 2 minutes l 2 3 4 Select CLDI by pressing UP or DOWN button Press ENTER the display shows ON or OFF Press UP to select ON if you wish to enable this function or press DOWN button to OFF if you don t Press ENTER to confirm or Press MODE ESC to return to the main menu 0 XMO080 V1 0 NR un TT E Main menu 1 SEE Eee ee a a ls MAN ARM ib 1 dES SPEE nic Hued GEUN LESE LOJA HEr ON OFA ON OFF 630 590 104 2198 M00 F0 ON OFF En FF ON OFF D 0 0 49 1 Press MODE ESC to enter the main menu display flashing 2 Press UP or DOWN button to select SET
18. sure the safety relating and machine technical installations are approved by an expert before taking the device into operation for the first time These installations have to be approved by a skilled person once a year CAUTION Before taking into operation for the first time the installation has to be approved by an expert Cautions The effect should be installed outside areas where persons may reach it walk by or be seated Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury CAUTION The electric connection must only be carried out by a qualified electrician Before mounting make sure that the installation area can hold a minimum point load of 10 times the 0 XMO080 V1 0 NR device s weight Connect the fixture to the mains with the power plug Installation method via clamp Please refer to the picture below 2 0 1 Omega holders 1 2 3 Safety rope 4 Quick lock fastener ay ES Screw one clamp each via a M12 screw and nut onto the Omega holders Insert the quick lock fasteners of the first Omega holder into the respective hol
19. terial fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed CAUTION Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the lamp Please refer to the instructions under Installation instructions Should you need any spare parts please order genuine parts from your local dealer 00 XM080 V1 0 NR TECHNICAL SPECIFICATIONS Power supply 098VAC 50Hz 0 120VAC 50Hz 07208VAC 50Hz 07220VAC 50Hz 0230VAC 50Hz 7240VAC 50Hz 098VAC 60Hz 0120VAC 60Hz J208VAC 50Hz 07220VAC 60Hz 107230VAC 60Hz 107240VAC 60Hz Power consumption max 45W Motors 1 micro motors PCB model MH 250 PT 05D PCB fuse F1 4L F2 5L 2PCS Packing dimensions 45x31x49cm Net weight 10 5 KGS Gross weight 14KGS Remark errors and omissions for every information given in this manual excepted All information is subject to change without prior notice 00 XM080 V1 0 NR
20. tton in order to select the desired menu You can change the selection by pressing the Up button or Down button Confirm every selection by pressing the Enter button You can leave every mode by pressing the Mode esc button The functions provided are described in the following sections Default settings shaded ADDR VALU A001 A511 AXXX DMX address setting SLAV ON OFF SLAV Slave setting AUTO ALON AU A Automatic Run in Stand Alone MAST AU M Automatic Run as Master RUN ALON SO A Sound controlled Run in Stand 0 MODE SOUN Alone MAST SO M Sound controlled Run as Master VALU D XX Bl00 DXXX a e 512 value of DISP RDIS ON OFF Reverse display CLDI ON OFF Shut off LED display RPAN ON OFF Pan Reverse 16BI ON OFF Switch 16 bit 8 bit DEGR 630 540 Pan degree select SPEE LOW HIGH Pan Tilt speed mode select i SET MIC M XX M 70 Mic sensitivity AUTO ON OFF Automatic Run by no DMX SOUN ON OFF Sound Run by no DMX REST Reset LODA ON OFF Restore factory settings VER V 1 0 V 9 9 Software version MATI 0000 9999 hours Fixture running time 2 TIME CLMT ON OFF Clear fixture time STEP S 01 S 48 Steps of Program Run REC RE XX Auto Save Scene 3 EDIT ay C 01 C 30 5u OO Edit the channels of each scene SC48 TIME T XXX 001 999 Time for each scene CNIN ON OFF Edit program via controller Note By default setting the lamp is not ignited with power o
21. u can run the internal program You can set the number of steps under Step You can edit the individual scenes under Edit You can run the individual scenes either automatically AUTO i e with the adjusted Step Time or sound controlled SOUN The selection ALON means Stand Alone mode and MAST that the device is defined as master 0 XM080 V1 0 NR gt m al gt rr co ja F Ley ca HASE SOU AL a I ASE 1 Select AUTO or SOUN by pressing UP or DOWN button 2 Press ENTER for selecting the desired extension menu 4 Select ALON or MAST by pressing UP or DOWN button 5 Press ENTER to confirm or Press MODE ESC to return to the main menu IGP Ota Display the DMX value Reverse display Shut off LED display Hdd El id 15P MALU d 00 I rd 15 OM OFF I LLa I O GFF ic td LW Ht LW Display the DMX 512 value of each channel With this function you can display the DMX 512 value of each channel l 2 3 4 Select VALU by pressing UP or DOWN button Press ENTER to confirm the display shows D 00 In this setting the DMX adjustment of every channel will be displayed The display shows D XX XX stands for the DMX value of the selected channel Press UP or DOWN button in order to select the desired channel If you select D 14 the display will