Home

HM 110 - HITMA Instrumentatie

image

Contents

1. regulator PLC passive type 2 wires CONFIGURATION VIA LCC S SOFTWARE option An easy and friendly configuration with the software It is possible to configure an offset Example the instrument could be configured from 30 to 50 RH In order to compensate a possible drift of the transmitter it is possible to add an offset to the displayed value by the HM110 instrument it shows 48 RH a standard instrument shows 45 RH It is then possible via the software to integrate an offset of 3 to the displayed value by the HM110 instrument e To access the configuration via software Connect the cable of the LCC S to the connection of the transmitter Please refer to the user manual of the LCC 100 to make the configuration MOUNTING To mount the transmitter mount the ABS plate on the wall drilling 6 mm screws and pins are supplied Insert the transmitter on the fixing plate see A on the drawing beside Rotate the housing in clockwise direction until you hear a click which confirms that the transmitter is correctly installed 23 5 mm Ambient model does not have any mounting plate 4 fixing holes are present inside the back housing Use them to install the transmitter on the required location 68 mm MAINTENANCE Please avoid any aggressive solvent Please protect the transmitter and its probes from any cleaning product containing formalin that may be used
2. KIMO INSTRUMENTS Humidity transmitter HM 110 KEY POINTS Measuring range from 5 to 95 RH 0 10 V output active power supply 24 Vac Vdc 3 4 wires or 4 20 mA output passive loop power supply from 16 to 30 Vdc 2 wires ABS V0 housing IP65 duct or remote model or IP20 ambient model with or without display Ya turn system mounting with wall mount plate Housing with simplified mounting system FEATURES OF HOUSING Duct model 41 mm 46 mm Technical Data Sheet Pressure Temperature Humidity Air Velocity Airflow Sound level coo Da ee DE Pan HR M 110 On HM 119 O oe 7 Se aE T Sz 2 K Cav il Material ABS V0 as per UL94 Protection IP65 remote and duct models IP20 ambient model Display LCD 10 digits Size 50 x 17 mm Height of digits Values 10 mm Units 5 mm 109 mm PART NUMBER To order just add the codes to complete the part number mL Ol Cd S Ambient Power supply Output A Duct A Active 24 Vac Vde 0 10 V D Remote P Passive 16 30 Vdc 4 20 mA Display O with display N without display iN Cable gland remote and duct models For cables 8 mm maximum 150 mm Weight 145 g ambient model 223 g remote and duct models Cable of remote probes length 2 m and 4 8 mm in silicone Example HM110 ANS Ambient
3. for cleaning rooms or ducts OPTIONS AND ACCESSORIES e KIAL 100A Power supply class 2 230 Vac input e Stainless steel sliding e Stainless steel connections 24 Vac output fittings e Wall mount plate for e LCC S configuration software with USB cable e PC cable gland humidity remote probe e ABS connection with connection gland Distributed by irae EXPORT DEPARTMENT Tel 33 1 60 06 69 25 Fax 33 1 60 06 69 29 Qualit e mail export kimo fr FTang transmitter_HM110 08 03 13 RCS 24 P rigueux 349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice
4. humidity transmitter HM110 active 0 10 V without display TECHNICAL FEAUTURE IN HUMIDITY Measuring range from 5 to 95 RH Accuracy 1 5 RH if 15 C lt T lt 25 C on remote and duct models 2 RH if 15 C lt T lt 25 C on ambient model Drift linked to temperature 0 04 x T 20 RH if 15 C lt T lt 25 C Unit of measurement RH Response time 1 e 63 4 s Type of sensor Capacitive on remote and duct models CMOS on ambient model Resolution 0 1 RH Factory adjustment uncertainty 0 88 RH Type of fluid Air and neutral gases All the accuracies indicated in this technical datasheet were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with calibration compensation As per NFX 15 113 and the Charter 2000 2001 HYGROMETERS GAL Guaranteed Accuracy Limit which has been calculated with a coverage factor value of 2 is 2 58 RH between 18 and 28 C on the measuring range from 3 to 98 RH Sensor drift is less than 1 RH year TECHNICAL SPECIFICATIONS Output Power supply active sensor 0 10 V power supply 24 Vac Vdc 10 3 4 wires passive loop sensor 4 20 mA power supply 16 30 Vdc 2 wires maximum load 500 Ohms 4 20 mA minimum load 1 K Ohms 0 10 V Consumption 2 VA 0 10 V or max 22 mA 4 20 mA Electromagnetical compatibility EN61326 Electrical connection Screw terminal block for cables 0 05 to 2 5 mm PC co
5. mmunication Kimo USB mini Din cable Environment Air and neutral gases Operating temperature of the From 0 to 50 C housing Operating temperature of the From 20 to 80 C probe Storage temperature From 10 to 70 C CONNECTIONS Inside the front housing Fixed back housing Removable front face yo muane st mus anses ATL ee i i seer SN O aana le pan a aueneeee Output terminal i Power supply terminal block block LCC S connection Inactive Active Cable gland switch switch S1 ELECTRICAL CONNECTIONS as per NFC15 100 standard A This connection must be made by a qualified technician To make the connection the transmitter must not be energized For HM110 AO and HM110 AN models with 0 10 V output active To make a 3 wire connection before powering up the transmitter please connect the output ground to the input ground See drawing below GND VRH 3 GND VRH 1 2 3 4 5 6 7 QO 0 10 V output Power supply 24 Vdc V Display regulator PLC passive type Display regulator PLC Passive type 0 10 V output Power supply 24 Vac class Il Power supply 24 Vac 4 wires Ni class II wwe ee ee ee eee ee ee ee ee ee ee ee ee ee ee eee For HM110 PO and HM110 PN models with 4 20 mA output passive IRH Vde 1 2 3 4 5 6 7 Power supply 16 30 Vdc Display regulator PLC passive type 4 20 mA output 4 20 mA output Display