Home

Grandstream GXV3674 User Manual

image

Contents

1. Customizable email subject for user convenience e Email Content Customizable email body for user convenience Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 28 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video NOTE gt Click Save to save the email configuration information gt Click Test after configuration if setting is correct a test email will send out and Test successful orange bar will display like below Enable SMTP Vv SMTP Server smtp gmail com SMTP Server Port 465 User Management Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 29 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video FTP Settings Page Upload Alarm This page allows user to configure FTP parameters to upload the alarm or video recording FTP Settings Enable FTP Vv FTP Server myftp cloud net FTP Server Port 21 User Management User Name subscriber12 Maintenance SMTP Password scsse Path AlarmRecording Alarm Server Valid DNS server is required for hostname Motion Detection Save Test Syslog Figure 13 FTP Setting Page e Enable FTP When checked built in FTP client is enabled e FTP Server IP or Domain name of FTP site or server e FTP Server Port TCP port for FTP server default port number 21 e User Name FTP server User ID e Password FTP server user passwor
2. Focal Length 2 8 12 mm Aperture F1 4 DC IRIS Field Angle FOV 90 28 Horizontal Field IR Cut Filter Yes Mechanical Day amp Night Mode IR LED covering up to 25m Minimum Illumination 0 05 Lux 0 lux with IR Responsivity 5 48V lux sec 550nm 1 9V lux sec 550nm Pixel Dynamic Range Wide Dynamic Range of Wide Dynamic Range of 120dB with SNRuax 44dB 100dB with SNRmax 39dB Supported Maximum Video 1280x960 25fps 2048x1536 15fps Resolution and Frame Rate 1280x720 30fps 1920x1080 30fps Video Bit Rate 32 Kbps 8 Mbps multi rate for preview amp recording Audio Input Line In 1500 ohms 0 1Vrms 0 707Vrms Audio Output Line Out 600 ohms 0 707Vrms Audio Compression G 711u a AAC Embedded Analytics Motion Detection up to 16 target areas Pre post alarm Buffer 8MB 3MB Snapshots Triggered upon events send via email FTP Network Protocol TCP UDP IP RTP RTCP RTSP DHCP DDNS HTTP HTTPS SMTP FTP NTP SIP VolP Support Yes Power over Ethernet PoE IEEE 802 3af Class 0 External Cable Connection Network RJ45 10M 100M auto sensing 3 5mm Line In 3 5mm Line Out Power Input Dimensions L x W x H 255mm L x 104mm W x 187mm H Weight 1 10kg Temperature Humidity Operating 20 C 50 C 4 F 122 F 10 90 RH non condensing Storage 30 C 60 C 22 F 140 F Power Adapter Output 12VDC 1A Inp
3. 14 ALARM HTTP SERVER SETTING PAGE cccccccsccssessscecececsessnnsaecececeesesseaesecececeeeaaeeeeececsessuaseeseesesenenaeseseeeens 31 FIGURE 15 1 MOTION DETECTION CONFIGURATION PAGE cc ccccccceesssssceceeececsenseaeseeececeessaeseeeceesensaaeseseceesenensaeeeeeens 32 FIGURE 15 2 MOTION DETECTION SCHEDULE CONFIGURATION PAGE ccccccsessssesecececeessaeeeeeceesensuaesesececeesenasaeseeeens 33 FIGURE 16 ALARM SERVER SETTING PAGE cccccccssesssseseeececeseseeececeessaacaesececcesenseaesecececeeseaaesesececsensuaesecececeeneasaeseeeens 34 FIGURE 17 FIRMWARE UPGRADE AND PROVISIONING ccceceesescececececessccecececeeneseaececececsesssesececeesesaaseeeececsensaseeeeeees 35 FIGURE 18 FACTORY RESET FROM WEB INTERFACE ccccssssssscecececeesssccecececeeseueaecececeeseseaeceecceesesnsaseeeceseeensaaseeeeeeces 37 TABLE OF TABLES GXV3674_HD FHD_VF USER MANUAL TABLE 1 GXV3674 HD FHD VF TECHNICAL SPECIFICATIONS errvvvvvvrvnvvnvevevvvevevenevenenevevenerenevenerenvnenenenenenennnensnveveen 10 Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 3 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video WELCOME Thank you for purchasing Grandstream s GXV3674 series Outdoor Day Night Vari focal High Definition IP Camera an innovative powerful weatherproof infrared next generation high definition network camera Its advanced ISP Image Sensor Processor powered wit
4. Connect the other end of the RJ 45 cable to your PoE switch Please refer to following connection diagram to hook up the camera Power Port Option A Power Adapter To AC Outlet 5 Option B RJ45 Ethernet Cable to Power over Ethernet PoE Switch NOTE Choose Option A if using the power supply or choose Option B if using a Power over Ethernet PoE switch Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 8 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Product Overview GXV3674 HD FHD VF Camera EE ere g 1 Screw and Top Cover GXV3674_HD FHD_VF screw and top cover 2 IR LED Light IR LED light for night mode 3 LENs Adjustable Vari focal Lens 4 IR CUT Sensor IR Cut Photonic Sensor 5 Far Near Adjustment Light Sensor for mechanical IR Cut switching 6 Focus Adjustment Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 9 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream GXV3674 HD FHD VF Specifications Table 1 GXV3674 HD FHD VF Technical Specifications Model GXV3674 HD VF GXV3674 FHD VF Video Compression H 264 MJPEG Image Sensor Resolution 1 3 1 2 Megapixel 1 3 3 1 Megapixel Progressive Scan CMOS Progressive Scan CMOS 1280H x 960V 2048H x 1536V Image Sensor Sensitivity Day amp night mode exceptionally low noise levels and low light sensitivity Shutter 1 10000 1 30 second
5. Firmware Version 1 0 2 12 Last Updated 06 2013 ndstream Innovative IP Voice amp Video Motion Detection Configuration Page Set Alarm This page allows user to configure motion detection to trigger alarms Motion Detection Region Settings User Management Maintenance W Enable Motion Detection SMTP W Show Motion Detection Regions FTP 0 gt Select a Region 50 Sensitivity Save Edit Remove Save Alarm Server Motion Detection Alarm Action Record Video From Pre Alarm Up to 10 gt seconds to After Alarm Up to 20 gt seconds Voice Alarm to SIP Phone Upload to Alarm HTTP Server Record Video and Upload to FTP Server Vv ra Z Upload to Alarm Center W Email and FTP upload JPEG Save Motion Detection Time Schedule Figure 15 1 Motion Detection Configuration Page e Enable Motion Detection When checked Motion Detection enabled e Show Motion Detection Regions When checked Motion Detection region with number will be displayed in White Rectangle in the screen when Edit clicked the Rectangle will become Red as shown in Figure 16 1 e Select a Region Pull down to select and configure alarm region altogether 16 alarm region available from 0 to 15 e Sensitivity Select configured alarm region number input number for sensitivity to trigger alarm 100 is the maximum sensible value Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 32 of 41 Firmware
6. User Manual Page 20 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Networking Setting Page IP Address Configuration C Dynamically Assigned via DHCP Statically Configured as IP Address 192 168 1 68 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 DNS Configuration Obtain DNS Server Address Automatically amp Use the Following DNS Server Address Primary DNS Server 64 119 143 2 Secondary DNS Server 71 243 0 12 HTTP HTTP Port 8088 Save Figure 6 Networking Setting Page e IP Address Configuration Camera IP address configuration o Dynamically Associated via DHCP Default setting DHCP server assign IP to camera o Statically Configured as Static IP address configuration e DNS Configuration DNS server IP must be configured correctly if using static IP e HTTP Web access TCP port default 80 NOTE gt If camera behind SOHO router with port forwarding configuration for remote access static IP or static DHCP has to be used to avoid IP address change after router reboot gt TCP port above 5000 suggested if port forwarding HTTP remote access due to some ISP would block port 80 inbound traffic For example change the default HTTP port from 80 to 8088 to make sure the port forwarding not likely be blocked gt In addition to HTTP port RTSP port also required to be configured for port forwarding in order for remote party viewing the
7. Zan Innovative IP Voice amp Video Grandstream Networks Inc GXV3674 HD VF GXV3674 FHD VF Outdoor Day Night Vari focal HD IP Camera GXV3674 HD FHD VF User Manual www grandstream com Firmware Version 1 0 2 12 http esupport grandstream com andstream Innovative IP Voice amp Video TABLE OF CONTENTS GXV3674 HD FHD VF User Manual WELCOME enn 4 SAFETY COMPLIANCES L l u l L nn nn a 5 WARRANT Y aeee aaa Susa aasaasqdaskuyakasssua pakke edda de dre nej eee aden tata neben id dacs teulleedevaeeeaeuvidddussvaauedusniddeseeess 6 CONNECT YOUR GXV3674 HD FAD VEZ u a Susa aasawa taasaqassussk 7 EQUIPMENT PACKAGE CONTENTS L I I nn n SSS 7 CONNECTING THE GXV3674 HD FHD VF eenen eneerensneeerensnneerenanneerenanseerenanseerenanneeeenanneenenn 8 PRODUCT OVERVIEW i u u L enone eaten eee ee el 9 GXV3674 HD FHD VF CAMERA mnnavsernnnavvennnnnvsennnnavsennnnnvsvnnsnavsernsnansvnnsnnvsvsnsnnvsnnnnnnssnsnnnnvsnnnsnnvsesnnnnvseensnns 9 GXV3674 HD FHD VF SPECIFICATIONS c0 cccesssssecsssessecsesensecsesensecseseesecsesensecsesensecseenssecsesenseesesenaess 10 INSTALLATION GUIDE ae nen ene eet ee 11 MINIMUM RECOMMENDED COMPUTER SYSTEM REQUIREMENT I enennenssnse eenen ensen 11 CONFIGURE THE GXV3674 HD FHD VF VIA WEB BROWSER aaneen eneen eneneneereneere n naa 11 GXV3674_HD FHD_VF HOME WEB PAGE nano eneenensnneenenenneenenenneer
8. allow only white list number to call in for security e Enable Dual way Audio Warning Check to enable two way audio when call established Default e SIP Proxy Compatibility Mode Check to enable more proxy compatibility with cost of bandwidth Self define Warning Audio Upload self defined warning message audio follow the format e Phone List Phone Number Callee or call receiver s number when alarm call trigged e White List Phone Number Phone numbers allowed calling into the camera Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 24 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 Status Page This page shows the GXV3674 HD FHD VF operation status andstream System Video amp Audio CMOS Settings Networking DDNS SIP Status ndstream Innovative IP Voice amp Video System Statistics Product Model Hardware Version Part Number Bootloader Version Core Version Base Version Firmware Version System Up Time Since V1 0A 9670004710A 1 0 2 8 1 0 2 8 1 0 2 8 1 0 2 8 10 hours 27 minutes Network Status MAC Address LAN IP Address LAN Subnet Mask LAN Default Gateway DDNS Status SIP Registered 00 0B 82 27 F8 C2 192 168 89 179 255 255 255 0 192 168 89 1 Disabled Offline Camera Type Camera Type Aptina AR0130 Pixels 1280 960 Figure 9 Status Page NOTE gt When SIP account registered the status w
9. the camera enabled anonymous access Click Configuration the browser will ask credentials to authorize configuration Enter the administrator user name and password to access the Web Configuration Interface the default user name and password are both set to admin 9 In step 6 browser will indicate that This website wants to install the following add on GS ViewerX cab from Grandstream Networks Inc allow the installation 10 The plug in can be download here http www grandstream com products tools surveillance webcontrl_plugin zip NOTE gt Please temporarily disable Antivirus or Internet Security Software and close all browsers when download and install the Grandstream Plug in Software Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 12 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Connect to the Camera using Static IP If no DHCP server in the network or the camera does not get IP from DHCP server user can connect the camera to a computer directly using static IP to configure the camera The default IP if no DHCP server or DHCP offer time out 3 minutes is 192 168 1 168 Connect the computer RJ 45 via an Ethernet cable directly to the IP camera GXV3674 HD FHD VF 2 Configure the computer using Static IP 192 168 1 XXX 1 lt XXX lt 255 but NOT 168 and configure the Subnet mask to 255 255 255 0 Leave the Default Ga
10. 11 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Connect the Camera to network with DHCP server Recommended The GXV3674_HD FHD_VF by default enabled as DHCP client it will automatically get IP address from the network with DHCP server running User can know the IP address assigned to the camera from DHCP server log or using SearchTool from Grandstream GSurf_Pro free VMS software 1 Download and install the GSurf_Pro software from Grandstream website http www erandstream com products tools surveillance gsurf_pro zi 2 Run the Search Tool in the pull down Menu of Manage Tool tag 3 Click on 88 button to begin device detection 4 The detected devices will appear in the Output field like below Search Ol x Index Model Version DeviceName 1P HTTP Port RTSPPot MAC 1 IPCAMERA GXV3615WP_HD 1 0 1 75 192 168 22 144 80 554 00 08 82 2 IPCAMERA 3601HD 1 0 4 38 GXV3601HD 4 19216822116 80 554 00 08 82 el Cen PD Add IP Address Configuration wifi Configuration js Old IP I I Use DHCP Sub net mask Gate way 5 Double click the column of the detected camera the browser will automatically open and link to the device IP and the web configuration page 6 The browser will ask for plug in or ActiveX if not installed otherwise it will get to Home page and start to show the video captured by the camera by default
11. 40 43 z 256 gt kbps 30 gits zo Frame 1 100 m Audio Settings Preferred Audio Codec Microphone Volume Speaker Volume Power Frequency Power Frequency Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Firmware Version 1 0 2 12 Page 17 of 41 Last Updated 06 2013 ndstream Innovative IP Voice amp Video On Screen Display OSD Display time stamp and text on the video screen OSD Text OSD Position Display Time Display Text oo 070 e Video Settings Video Settings Primary Stream Settings Preferred Video Codec Resolution Bit Rate Maximum Frame Rate Bit Rate Control Image Quality frame Interval Secondary Stream Settings Preferred Video Codec Resolution Bit Rate Maximum Frame Rate Bit Rate Control frame Interval Input text to identify the camera shown on the screen Show the OSD in either top or bottom left position on screen When checked time stamp will display on video screen When checked input text will display on video screen H264 gt 1280 720 16 9 gt 2048 gt kbps 30 fps oc CBR lt VBR Very High po Frame 1 100 H264 320 240 4 3 gt 256 kbps 30 fps CBR VBR 30 Frame 1 100 Figure 4 2 Video amp Audio Settings Page e Primary Stream Settings Preferred Video Codec Resolution Bit Rate Maximum Frame Ra
12. H 264 video gt If change the default port from TCP 80 to port A then RTSP port should be 2000 A Both TCP port A and 2000 A should be configured for port forwarding in the router For example the HTTP port changed to 8088 the RTSP port should be 10088 both 8088 and 10088 should be configured for port forwarding in order for remote camera video access Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 21 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video DDNS Settings Page This page allows user to configure dynamic DNS related parameters GXV3674 HD VE Administration Interface lt r Dynamic DNS Settings DDNS Active r DDNS ISP Type dyndns org Self Define DDNS Address Video amp Audio Site Name CMOS Settings i Networking DDNS Account DDNS Password w SIP STUN Server Save Status Figure 7 DDNS Setting Page e DDNS Active Enable DDNS by check this field e DDNS ISP Type Select the DDSN service provider from the pull down menu list e Self Define DDNS Address Input the self defined DDNS address e Site Name DDNS site name e DDNS Account DDNS account name e DDNS Password DDNS password e STUN Server Stun server FQDN or IP If device behind a non symmetric router STUN server can help to penetrate amp resolve NAT issue Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 22 of 41 F
13. IIS web server Configuration File Download Grandstream SIP Device can be configured via Web Interface as well as via Configuration File through TFTP or HTTP HTTPS Config Server Path is the TFTP or HTTP HTTPS server path for configuration file It needs to be set to a valid URL either in FQDN or IP address format The Config Server Path can be same or different from the Firmware Server Path A configuration parameter is associated with each particular field in the web configuration page A parameter consists of a Capital letter P and 1 to 3 Could be extended to 4 in the future digit numeric numbers i e P2 is associated with Admin Password in the ADVANCED SETTINGS page For a detailed parameter list please refer to the corresponding firmware release configuration template When Grandstream Device boots up or reboots it will issue request for configuration file named CfQXXXXXXXXXXXX XMI where xxxxxxxxxxxx is the MAC address of the device i e cfg000b820102ab xml The configuration file name should be in lower cases Currently GXV3674_HD FHD_VF only support XML configuration Grandstream Networks Inc GXV3674 HD FHD VF User Manual Page 36 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 RESTORE FACTORY DEFAULT SETTING WARNING dstream Innovative IP Voice amp Video Restoring the Factory Default Setting will DELETE all configuration information of the camera Please BACKUP o
14. Plug in Software Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 13 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 ndstream Innovative IP Voice amp Video GXV3674 HD FHD VF Home Web Page The Home Page of GXV3674 HD FHD VF shown as Figure 1 GXV3674 HD VF Figure 1 Home Page of GXV3674 HD FHD VF bed rn SPINA 11 12 13 14 15 16 17 18 Control Console ZOOM FOCUS PTZ SPEED Default Button D BRIGHTNESS CONTRAST SATURATION View Size Configuration Language Play Stop Snapshot Capture Record Sound On Off Talk Playback Local Configuration Motion Detection Alarm Indicator PTZ Console controller for ePTZ function Zoom in or Zoom out during ePTZ operation Adjust the focus of image Not Applicable to GXV3674 HD FHD VF Adjust the rotate speed of the control console Not Applicable Default Button to reset the video brightness contrast and saturation value from auto or manual adjusted value to factory default value Adjust the image or video brightness Adjust the image or video contrast Adjust the image or video saturation Adjust the size of viewed image or video Click to enter Configuration Page to configure the parameters of GXV3674_HD FHD_VF Administration privilege required Click to switch webpage language Current support Chinese English and Russian Start Stop playing the video stream at emb
15. Server Upgrade via HTTP gt Motion Detection Firmware Server Path firmware grandstream com Syslog Config Server Path config grandstream com XML Config File Password eee Automatic Upgrade Interval Minutes 10080 Automatic Upgrade Vv _Save Figure 17 Firmware Upgrade and Provisioning NOTE gt Grandstream recommends end user use the Grandstream HTTP server gt Currently the HTTP firmware server is firmware grandstream com For large companies or user without Internet connection we recommend maintaining their own TFTP HTTP HTTPS server for upgrade and provisioning procedures Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 35 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video Instructions for local firmware upgrade using TFTP server 1 Unzip the file and put all of them under the root directory of the TFTP server 2 Putthe PC running the TFTP server and the device in the same LAN segment 3 Please go to File gt Configure gt Security to change the TFTP server s default setting from Receive Only to Transmit Only for the firmware upgrade 4 Start the TFTP server in the phone s web configuration page 5 Configure the Firmware Server Path with the IP address of the PC 6 Update the change and reboot the unit End users can also choose to download the free HTTP server from http httpd apache org or use Microsoft
16. Version 1 0 2 12 Last Updated 06 2013 Alarm Action e Record Video From e Voice Alarm to SIP Phone e Upload to Alarm Center e Upload to Alarm HTTP Server e Record Video and Upload e Email and FTP upload JPEG NOTE andstream Innovative IP Voice amp Video Allow user to configure how long pre post alarm trigger moment the video to be captured by the camera When checked and SIP proxy configured and IPCam registered SIP alarm call will be made to pre configured number When checked the alarm video will be transferred to Alarm Center like Grandstream free GSurf Pro VMS software When checked the alarm will be sent to Alarm HTT Server Third Party Server also can be used via GS HTTP API When checked and FTP server configured the recorded video will be FTPed to the configured FTP server When checked snapshots of trigger moment will be generated and be emailed to pre configured email account also upload to FTP server if configured gt Grandstream free GSurf Pro VMS software can be downloaded here http www grandstream com products tools surveillance gsurf_pro zip Motion Detection Time Schedule This page allows user to configure Motion Detection Operation Schedule Motion Detection Time Schedule Region ID Date Start Time End Time 0 sf Everyday 00 00 08 00 Add 0 Everyday 20 00 23 59 2 0 Everyday 00 00 08 00 2 7i Un Check All Delete Figure 15 2 Motion Detection Schedule Config
17. WARE UPGRADE inbitte etset rentene aent ae aaaea aE nda 35 SOFTWARE UPGRADE VIA TTFP HTTP OR HTTPS nanne nnenensensenensersenensersenenserseneserssnensensnnensevenn 35 INSTRUCTIONS FOR LOCAL FIRMWARE UPGRADE USING TFTP SERVER nn nasa 36 CONFIGURATION FILE DOWNLOAD U 36 RESTORE FACTORY DEFAULT SETTING susen wns 37 RESET FROM WEB INTERFACE ninnan aaant naana aaa a aa aaa ean a aa aa aaa aa a aa a aa aa aaa aa aa a aa 37 IP SURVELLANCE FAQ nimeer eenen ee aY 38 Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 2 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video TABLE OF FIGURES GXV3674 HD FHD VF USER MANUAL FIGURE 1 HOME PAGE OF GXV3674 HD FHD VF ihororvrononnnnnorvrnrnrnnennnnrnrnenssernanrrnnsnnsnnnsnnrnnnsnssnennnnrnnnenssennannrnnsenssnennne 14 FIGURE 2 WEB LANGUAGE SWITCH unnarennet redene des 15 FIGURE 3 SYSTEM SETTINGS PAGE ung u uuu a a aqu ua berede N 16 FIGURE 4 1 VIDEO amp AUDIO SETTINGS PAGE cccsssscccccecsesessececececsesessscecececeeseneaeceeccseseesaeceecceceeaaeeeeeesceeseaeeeeeeeees 17 FIGURE 4 2 VIDEO amp AUDIO SETTINGS PAGE urrnnnorornrrrrnennnnrnrnensersnennnnrnensnresannnnnnensnrsnannnnnnensnssnnnannrnenenessenannrnnnenssnnnene 18 FIGURE 5 CMOS SETTINGS PAGE rrrrrnnnnnornrnrnrsnensnnrnrnerssnenannrnrnenserenennrnnnensnsenannnnnnensnssnannnnnnensnssnena
18. al computer Set the Time Manually Manually input the time o Keep Current D T Select to use camera current displayed time e OSD Date Format Pull down to select date format displayed on video screen e Device Name The name of device which will be shown in the result of Search Tool of GSurf_Pro VMS program NOTE If select this option a valid DNS server must be preconfigured under Basic Settings gt Networking gt Save button has to be clicked to save all the changes made to the device Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 16 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 Video amp Audio Setting Page This page allows user to configure the video and audio related settings System Video amp Audio CMOS Settings Networking DDNS SIP Figure 4 1 Video amp Audio Settings Page _VE Administration Interface a Gin Innovative IP Voice amp Video OED Text OED Position Dispiay Time Display Text Gxv3674 HD VF 109 F ra Video Settings Primary Stream Settings Preferred Video Codec Resolution Bit Rate Maximum Frame Rate Bit Rate Control Hrame Interval Secondary Stream Settings Preferred Video Codec Resolution Bit Rate Maximum Frame Rate Bit Rate Control frame Interval H264 280 720 169 2048 gt kbps 30 fps CBR VBR fo Frame 1 100 H264 3202
19. arts e g electrolytic capacitor of the equipment shall be replaced regularly according to their average life time The average life time varies from the differences between operating environments and usage history Regular maintenance checks are recommended for all users Please contact your dealer for more details Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 5 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video Warranty If you purchased your GXV3674 HD FHD VF from a reseller please contact the company where you purchased the device for replacement repair or refund If you purchased the product directly from Grandstream please contact your Grandstream Sales and Service Representative for a RMA Return Materials Authorization number before you return the product Grandstream reserves the right to remedy warranty policy without prior notification Caution Changes or modifications to this product not expressly approved by Grandstream or operation of this product in any way other than as detailed by this User Manual could void your manufacturer warranty Please do not use a different power adaptor with the GXV3674_HD FHD_VF as it may cause damage to the products and void the manufacturer warranty e This document is subject to change without notice The latest electronic version of this user manual is available for download at http www grandstream com products su
20. ate bandwidth and storage before installation http www grandstream com support tools bandwidth storage calc Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 19 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video CMOS Settings Page This page allows user to adjust the CMOS parameters GXV3674 HD VE Administration Interface ndstrean a System Video amp Audio CMOS Settings Networking DDNS SIP Status Flip Horizontal amp Vertical gt Iris Setting DCAuto Shutter Speed Auto gt IR CUT Setting Automatic IR sensor control gt IR CUT Sensitivity 3 gt Color Mode Auto gt Save Figure 5 CMOS Settings Page Flip Pull down to choose video flip either vertical or horizontal or both Iris Setting Pull down to choose Mechanical Manual DC Auto and DC Manual Default Auto e Shutter Speed Camera Shutter Speed There are 10 options with Auto 1 30 1 60 1 125 1 250 1 500 1 1000 1 2000 1 5000 and 1 10000 Default Auto IR CUT Setting Manual or Automatic IR sensor controlled mechanically switching IR CUT Sensitivity Sensitivity for IR CUT trigged total five levers from lever 1 to 5 e Color Mode Camera Color Mode There are three options Color Black White Auto Default NOTE gt Auto option recommended for Iris Setting Shutter Speed IR CUT Setting and Color Mode Grandstream Networks Inc GXV3674 HD FHD VF
21. ce amp Video 6 Why does IE indicate to install Grandstream Video Viewer add on after a firmware upgrade The add on was properly installed before the firmware upgrade process New firmware will often upgrade the add on as well To watch the live video stream you must install the newest version of the add on 7 How do you watch secondary video stream Login to the home page of the GXV3674 HD FHD VF web GUI click Play to watch the video stream To watch a secondary video stream right click on the video and select Secondary Stream on the pop up menu Try reinstalling the Grandstream Viewer add on for IE if you cannot see the video stream 8 What is DDNS Is it important for IP surveillance product to have DDNS support DDNS is an acronym for Dynamic Domain Name Service It is important to choose an IP network camera that has DDNS support for dynamic IP addresses Chances are that the network has a dynamic IP address which changes with every log on A DDNS service makes sure that the camera s IP address always matches up to the current server address DDNS also allows a website to be linked to the IP camera that is constantly updated with the correct information and has a reliable feed 9 Why is Windows Media Player unable to play the recorded video files The GXV3674 HD FHD VF uses the H 264 video codec Windows Media Player may lack the proper H 264 decoder to play the recorded video Please download the Microsoft FFDShow H 264 decoder
22. d 06 2013 dstream Innovative IP Voice amp Video Safety Compliances These instructions are intended to assist users with the operation of the GXV3674 HD FHD VF and to instruct on how to avoid dangerous situations or damage to the device Warnings Serious injury or death may be caused if any of the warnings below are neglected Cautions Injury or damage to the equipment may occur if any of the following caution messages are neglected Warnings Follow these safeguards to prevent Cautions Follow these precautions to serious injury or death prevent potential injury or material damage A Warnings Input voltage should meet both the SELV Safety Extra Low Voltage andthe Limited Power Source with DC 12V according to the IEC60950 1 standard Please refer to the technical specifications for more details Do not use athird party power adapter or power cord When the device is installed on the wall or ceiling make sure that it is firmly attached Notice Make sure that the power supply voltage is correct before using the camera Do not drop the device or expose it to physical shock Do not expose the device to temperatures outside the range of 10 C to 60 C when the device is in operation Do not expose the device to damp w et conditions or high electromagnetism radiation To avoid heat accumulation make sure that your operating environment has proper ventilation Do not attempt to open disassemble or modify the device Afew p
23. d e Path Path in the server where upload files are stored NOTE gt Click Save to save the FTP configuration information gt Click Test after configuration if setting is correct a test FTP operation will be performed and Test successful orange bar will display if the operation is successful Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 30 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Alarm Server Settings Page Upload Alarm to supported VMS or HTTP Server This page allows user to configure alarm HTTP server to upload alarms Alarm HTTP Server Settings Server Name Security Solution URL server911 cloud net 9999 User Name subscriber 110 User Management Password PPT Maintenance SMTP _Save FIP Alarm Server Motion Detection Syslog Figure 14 Alarm HTTP Server Setting Page e Server Name The name of HTTP server or VMS system e URL URL of the Server e User Name User ID from that Server e Password Password for that User ID NOTE gt Grandstream provide HTTP API to help third party companies by using HTTP server or VMS to develop further solutions for their customers http www grandstream com products surveillance general documents grandstream_http_api pdf gt Grandstream IP Camera and Encoder include GXV3674_HD FHD_VF are ONVIF certified Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 31 of 41
24. d Russian Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 15 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video BASIC SETTINGS EXPLANATION System Settings Page This page allow user to configure the system settings of GXV3674 HD FHD VF GXV3674_HD_VE_Administration Interface Se Aindstream ee Current System Time Date Time 03 58 06 System Video amp Audio Set the System Time CMOS Soliga Time Zone Using self defined Time Zone vil Networking Self Defined Time Zone EST 5EDT 4 M3 2 0 M11 1 0 DDNS Update via NTP Server Enable NTP Server Vv NTP Server time nist gov Synchronize with Local Computer Set the Time Manually Keep Current Date and Time _Save OSD Date Format OSD Date Format MM DDIVYYY vi Save Device Name Setting Device Name GXV3674 HD VF Save Figure 3 System Settings Page e Current System Time Display time current system is running at e Set the System Time Configure the time system is running o Time Zone Select from pull down menu the time zone unit located o Self Defined Time Zone Use the self defined time zone for automatic daylight saving time adjustment Format please refer to the help over mouse o Update via NTP Server Synchronize time using NTP protocol with a Time Server over the Internet cloud o Synchronize with Local Computer Synchronize time with loc
25. edded webpage Click to capture and save a snapshot of current video frame displayed Default directory C Capture Click to Start Stop record of current video stream into a file Default directory C Record Toggle to listen stop the sound from camera microphone Toggle to talk to camera speaker if provided PC microphone and related speaker hardware required Click to playback the recorded video file Click to configure the file path of snapshot and recorded video files Also adjust the video delay or smoothness If motion detection alarm triggered the indicator will flash in red if configured Click the indicator icon to turn off the alarm indication Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 14 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video GXV3674 HD FHD VF Configuration amp Language Page e When click the Configuration tab web page will link to page to configure the related parameters of the GXV3674 HD FHD VF e There are two big categories of settings Basic Settings and Advanced Settings Details will be illustrated in the later Chapter e When click the Language tab supported languages will be displayed in Figure 2 Click to select the related webpage display language Figure 2 Web Language Switch Configuration BER English Pyccku e Currently firmware only support English default Simplified Chinese an
26. enanneensnanneersnanneensnanneensnanneeens 14 GXV3674 HD FHD VF CONFIGURATION amp LANGUAGE PAGE a ensen 15 BASIC SETTINGS EXPLANATION mende ee tee ee eee 16 SYSTEM SETTINGS PAGE sadun uka aan asthalMasaasbaqasaykanmushisswa upasasakaykikhh reduserende 16 VIDEO amp AUDIO SETTING PAGE uu u uu uuu au aus aaa iaa aeta aaa aiaeei aa i aaa aani a aai 17 CMOS SETTINGS PAGE u unu u uuu rantan aae raa aai aaa aeaa aia a aada keepere qasa 20 NETWORKING SETTING PAGE U U U 21 DDNS SETTINGS PAGE svunne aiaa aaa ea aia a a eaae aaa eA aia 22 SIP SETTING PAGE EE EE EE 23 STATUS PAGE EE aaa aiea aaea a aa aE a EEEE N NEEE aa A a 25 ADVANCED SETTINGS EXPLANATION LLI III AA a a asssrssqaasssaaasaasasaqasqavaaqaawssaqqasssaaausae 26 USER MANAGEMENT PAGE u aa gm abbed 26 MAINTENANGE PAGE pressede benene maa ae eee da 27 SMTP SETTING PAGE EMAIL ALARM L L n sua 28 FTP SETTINGS PAGE UPLOAD ALARM nuno ansonerenseererenseerenenseersnenseerenenstereneneereneneeeenenseeennenteennensen 30 ALARM SERVER SETTINGS PAGE UPLOAD ALARM TO SUPPORTED VMS OR HTTP SERVFER 31 MOTION DETECTION CONFIGURATION PAGE SET ALARM nnn nn enenenerensnenerensnererensnneerenanneerenanneerenanneeeenn 32 SYSLOG SETTINGS PAGE TROUBLESHOOTING annae oennenensnneenenennvenenenseenenanneensnanneersnanneensnanneensnanneeens 34 SOFT
27. from http sourceforge net projects ffdshow tryout and install it 10 Alarm Triggered Events do not work with GSurf_Pro Please double check the Alarm Action on your GXV3674 HD FHD VF Login to the web GUI of the GXV3674 HD FHD VF go to the Motion Detection or Alarm Events page and make sure option Upload to Alarm Center is checked 11 Recommended to save the video files in different directories when using GSurf Pro It is better to save video files in different directory to prevent accidental deletion of the recorded files you need 12 How to use a cell phone to watch the GXV3674_HD FHD_VF video stream You must set the video resolution to QCIF to watch the GXV3674 HD FHD VF video stream from a cell phone Make sure to set the bit rate to 64kbps to ensure the best video quality 13 What Smartphone application should I use to view the video There are free application and paid version application for this like IP Cam Viewer http hit mob com Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 39 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video 14 Why the IP address of the device NOT reset when clicking the Restore button The GXV3674 HD FHD VF could be installed in areas that are not easy to access For example it could be installed on the roof of a building or the ceiling of an office This makes it difficult to reinstall the device therefore the Rest
28. ge3 Graphics SiS 661FX GX Mirage Graphics Intel G33 G31 Express Works normally Works normally Works normally S3 Graphics ProSavageDDR Microsoft Corporation Works normally XGI Velari Z7 Z9 Z9S V1 08 12 There is some delay when playing videos Intel 965 Express Chipset Family Works normally ATI Mobility Radeon X1300 Works normally Intel G45 G43 Express Chipset Works normally Mobile Intel 965 Express Chipset Family Works normally Mobile Intel 4 Series Express Chipset Family Works normally Mobile Intel 945GM Express Chipset Family Works normally Mobile intel 915GM GMS 910GML Express Chipset Family ATI Technologies RAGE XL PCI Intel G45 G43 Express Chipset Works normally Works normally This display adapter cannot display videos Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Firmware Version 1 0 2 12 Page 41 of 41 Last Updated 06 2013
29. h state of the art auto exposure auto white balance algorithm and a high quality lens ensures high fidelity video quality that matches digital still camera color grade in a wide range of light environments It features cutting edge H 264 real time video compression with excellent image clarity 720p for GXV3674 HD VF 1080p for GXV3674 FHD VF and color fidelity industry leading SIP VoIP for 2 way audio and video streaming to smartphones and video phones integrated PoE IR CUT mechanical for day or night mode and advanced security protection using strong encryption The GXV3674 HD FHD VF can be managed with GSurf Pro Grandstream s intuitive FREE VMS video management systems software that controls up to 36 cameras simultaneously It is fully compliant with ONVIF standard and offers flexible HTTP API and an SDK for advanced integration Designed for weatherproof applications the GXV3674 HD FHD VF Outdoor Day Night Vari focal HD IP camera is a new addition to the popular GX V3XXX series IP surveillance product family It ensures ease of use integration and deployment with multilingual graphical user interface provides powerful solution to professional surveillance applications This manual will help you to learn how to operate and manage your GXV3674_HD FHD_VF Outdoor Day Night Vari focal HD IP camera and make the best use of it Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 4 of 41 Firmware Version 1 0 2 12 Last Update
30. ill display Online in Green gt When SIP account unregistered the status will display Offline in Red as below SIP Registered Offline Grandstream Networks Inc GXV3674 HD FHD VF User Manual Firmware Version 1 0 2 12 Page 25 of 41 Last Updated 06 2013 dstream Innovative IP Voice amp Video ADVANCED SETTINGS EXPLANATION The supports all the traditional and advanced telephony features User Management Page This page allows user to do user management GXV3674 HD VE Administration Interface SS Manage User Existing User Name Add New User User Name User Management Maintenance SMTP FTP Privilege User Password Confirm User Password Administrator Administrator Manage Anonymous Viewing Alarm Server Allow Anonymous Viewing Motion Detection _Save Syslog Figure 10 User Management Page Existing User Name User Name User Password Confirm User Password Privilege Allow Anonymous Viewing Allow revise existing user or add new user The name of user need to be revised New password if revise password Re enter the new password for verification Choose user privilege When checked no security enhanced Any person can view the camera if knowing the IP or FQDN of the camera but can NOT change anything just view ONLY Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Firmware Version 1 0 2 12 Page 26 of 41 La
31. irmware Version 1 0 2 12 Last Updated 06 2013 SIP Setting Page dstream Innovative IP Voice amp Video This page allows user to configure SIP related parameters GXV3674 HD FHD VF can be configured as SIP endpoint to call out when alarm trigged or allow permitted number to call in to check the audio video if Grandstream IP videophone used General Phone Settings Registered Offline Jnregistar On Reboot O System p l SIP Settings Videov amp Audic Account Name IPPBX CMOS Settings Networking SIP Server gs_ucm isp com DDNS Outbound Proxy SIP User ID 6175669300 Status Authenticate ID 0039665716 Authenticate Password eee STUN Server mystun freebox net Stream Secondary gt Preferred Vocoder PCMU x Register Expiration Second 3600 local SIP Port 5060 local RTP Port 5004 Auto on Hook Timer 300 Disable Audio in SIP Call n Enable Keep Alive PM Accept Direct IP Call VW Figure 8 1 SIP Setting Page e Registered Unregistered on Reboot SIP registration status Display Online in Green Offline in Red If checked and server support reboot camera will unbind all registration in same SIP account e Account Name SIP account name e SIP Server FQDN or IP of SIP server from VoIP service provider Outbound Proxy IP or FQDN of Outbound proxy server helps penetrate NAT Firewall e SIP User ID SIP username or telephone number from ITSP e Authenticate ID Au
32. nnrnnnsnssnenannrnnnensnnnnene 20 FIGURE 6 NETWORKING SETTING PAGE rorvrvrnrrnnnnnnrnrnenssnensnnrnrnenssrenannrnnnensnsesannnnnnenssssnannnnnnensnssnnannrnnnenesnenannnnnnenssennene 21 FIGURE 7 DDNS SETTING PAGE rrrnrernnnnnnnrnrnrnrsnensnnrnrnerrsnenannrnrnenssrenennrnnnensnsenannnnnnensnssnanannnnensnssnenannrnnnenesnenannrnnnenssennene 22 FIGURE 8 1 SIP SETTING PAGE ccccccccccsssssecceececsesesaeeecccecseseaececececsenssssecececeeseseaeeeeeceesessaaeceesesceenaaeceeeesesenesaeeeeeeeees 23 FIGURE 8 2 SIP SETTING PAGE cc cccccccccssssssecccececsesssaeeeccceccenssaececececsessaaseesececeeseneaececececsesaaeseeceeesesnsaeeececeeseseaaeeeeeeeens 24 FIGURE 9 STATUS PAGE L cccccccssssccecececsessenececececeenssaececccecsensaaececececsessaseeeceeeceeneaseaeeecececsessaaeceeececeesnaaeeecececeeneaaeeeeeeeens 25 FIGURE 10 USER MANAGEMENT PAGE scsssccsccecsesssesecececcesessesesececeessnaeaesececeesensuaesecececeesuaaesececessessaaesesececeeseasaeteeeens 26 FIGURE 11 MAINTENANCE PAGE cccccccecssssscececececseseecceecceseaaesesecceeessaasaeseesceesensuaesecececeesuaaesececeesesuaesesececeesensnaeeeeeens 27 FIGURE 12 SMTP SETTING PAGE ccccccessssseccecsessesececececseseausesececeessaasaesececeesenseaeseeececseseaaeseeeesesesaassesececeenenseaeesesens 28 FIGURE 13 FTP SETTING PAGE c cccccccccssssscecececsesssececececceseauesesececsessaasaeseeeecesessuaeseeececeeseaaecesececsessaaesesecsceeneneaeseeeens 30 FIGURE
33. ore function will not clear the IP address 15 Why can t the live video stream be viewed using a mobile phone or GSurf Pro after changing the HTTP Port of the device Make sure that the RTSP port of the device is set to 2000 plus the HTTP Port number For example if the HTTP port is 88 then the RTSP port of the device that you configured on GSurf_Pro or mobile phone should be 2088 16 Port forwarding Two ports must be forwarded on your router to watch video from a GXV3674 HD FHD VF that is located on a private network from a PC in a public network The web port HTTP and the RTSP port Please make note that the RTSP port number changes according to the web port If the web port is 80 then the RTSP port is 554 If the web port is not 80 then the RTSP port equals the web port 2000 For example if the web port is 88 then the RTSP port will be 2088 Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 40 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 17 Tested PC display adapters andstream Innovative IP Voice amp Video Display Adapter Test Result SIS 650 651 740 661 FX 741 760 Series Works normally Intel 82945R Express Chipset Family Works normally VIA S3G UniChrome Pro IGP Works normally NIVDIA Geforce 7300GS Works normally SiS 661 FX Works normally SiS Mirage Graphics Works normally SiS 661 Series Works normally SiS Mira
34. r PRINT out all the settings before approach to following steps Grandstream will not take any responsibility if you lose all the parameters of setting or cannot connect to your VolP service provider FACTORY RESET Reset from Web Interface This page allows user to configure dynamic network related parameters Restart the device Restart the device Restart User Management Restore the device Maintenance Reset settings except IP address to factory default Restore Firmware Upgrade and Provisioning FTP Alarm Server Motion Detection Upgrade via HTP E Syslog Firmware Server Path firmware grandstream com Config Server Path config grandstream com XML Config File Password eee Automatic Upgrade Interval Minutes 10080 Automatic Upgrade Vv Save Figure 18 Factory Reset from Web Interface Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Firmware Version 1 0 2 12 Page 37 of 41 Last Updated 06 2013 andstream Innovative IP Voice amp Video IP SURVEILLANCE FAQ 1 What is the default IP address of the GXV3674 HD FHD VF A The default IP configuration is DHCP 2 Why can I not view the live video stream in Microsoft Internet Explorer A Please double check whether the Grandstream Plug in Active X is installed correctly Once you log into the GXV3674 HD FHD VF web interface Internet Explorer will indicate that this website wants to install to following add on GSVie
35. rks Inc GXV3674_HD FHD_VF User Manual Page 27 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 ndstream Innovative IP Voice amp Video SMTP Setting Page Email Alarm This page allows user to configure email client to send out email when alarm trigged SMTP Server Settings Enable SMTP 2 SMTP Server smtp gmail com SMTP Server Port 465 User Management From E Mail address my_gmail_id gmail com Maintenance To E Mail address 1 guard safety com FTP To E Mail address 2 6179116110 verizon net Alarm Server To E Mail address 3 worker abc_corp com Motion Detection User Name my_gmail_id Syslog Password eee SSL Vv Email Subject Front Door Motion Detected There is something wrong at the front door Please check out the camera immediately Ene Contest http IPCam myDDNS 0rg 10020 Port Mapped via Router 1 Required Fields 2 Valid DNS server is required for hostname Save Test Figure 12 SMTP Setting Page e Enable SMTP When checked email client is enabled e SMTP Server SMTP Email Server IP or Domain Name e SMTP Server Port Port number used by server to send email e From Email address The email address of alarm email sending from usually client email ID e To E Mail address The email address to receive the alarmed email total 3 included e User Name Email client User ID e Password Email client password SSL Check if the SMTP email server requires SSL e Email Subject
36. rveillance GXV361 Ohd documents GXV3674 HD FHD VF usermanual engli sh pdf Reproduction or transmittal of the entire or any part in any form or by any means electronic or print for any purpose is not permitted without the express written permission of Grandstream Networks Inc Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 6 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video CONNECT YOUR GXV3674 HD FHD VF Equipment Package Contents The GXV3674 HD FHD VF package contains GXV3674 HD FHD VF IP Camera 12V DC Universal Power Adaptor Ethernet Cable 1 Hex Key and 4 Screws and Wall Anchors Quick Installation Guide X GXV3674_HD FHD_VF I x 12V Power Supply D 1 x Ethernet Cable 4 x Wall Anchors l 4xScrews 1 x Hex Key x Quick Stori Guide Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 7 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Connecting the GXV3674 HD FHD VF Using the Power Adapter as power supply gt Connect the RJ 45 Ethernet cable to the NETWORK port of the GXV3674 HD FHD VF gt Connect the other end of the RJ 45 cable to your network switch or router or PC gt Connect the power supply to the DC 12V power jack on the back of the GXV3674 HD FHD VF Using PoE as power supply gt Connect the RJ 45 Ethernet cable to the NETWORK port of GXV3674 HD FHD VF gt
37. st Updated 06 2013 dstream Innovative IP Voice amp Video Maintenance Page This page allows user to maintain the camera GXV3674 HD VE Administration Interface Restart the device Restart the device Restart User Management Restore the device Maintenance Reset settings except IP address to factory default Restore Firmware Upgrade and Provisioning FTP Alarm Server Motion Detection Upgrade via HTTP Syslog Firmware Server Path firmware grandstream com Config Server Path config grandstream com XML Config File Password eee Automatic Upgrade Interval Minutes 10080 Automatic Upgrade Vv _Save Figure 11 Maintenance Page e Restart When clicked the camera will reboot or restart e Restore When clicked the camera will be reset to factory default wiping out all the configurations except IP address Firmware Upgrade and Provisioning e Upgrade via Upgrade firmware via TFTP HTTP or HTTPS e Firmware Server Path Server path holding the firmware e Config Server Path Server path holding the configuration file auto provisioning e XML ConfigFile Password Password for encrypt the XML based configuration file e Automatic Upgrade Interval Minutes Time interval for automatic upgrade default 10080 e Automatic Upgrade Checked to enable automatic firmware upgrade and provisioning NOTE gt Only XML based automatic provisioning is supported by GXV3674_HD FHD_VF Grandstream Netwo
38. te Bit Rate Control Image Quality I frame Interval ooo 0000 e Secondary Stream Settings MJPEG and H 264 supported H 264 recommended The video resolution in pixels used in video of camera Video bit rate used Maximum frame rate used More data if big frame used Constantly bit rate or variable bit rate Image quality selection when Variable Bit Rate used I frame interval Pull down to select same as Primary steam Grandstream Networks Inc GXV3674 HD FHD VF User Manual Page 18 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video e Audio Settings Pull down to select Audio Codec PCMU PCMA AAC supported Audio can also be disabled via choice o Microphone Volume Slide to adjust microphone gain o Speaker Volume Slide to adjust the speaker volume connected e Power Frequency Select correct local power frequency to avoid video flicking effect under fluorescence light condition Default is Outdoor NOTE v H 264 suggested if camera needs to be viewed via Internet v If MJPEG selected reduce max frame rate to min value to save bandwidth and get better image v Grandstream IP Camera provides two video streams user can use them with flexibility For example the high resolution stream for local recording another low or high resolution for remote monitoring or vice versa depending application scenarios gt Use below link to calcul
39. teway to Blank like below ax General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings C Obtain an IP address automatically Use the following IP address IP address 192 168 1 10 Subnet mask 255 255 255 0 Default gateway p as C Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server validate settings upon exit Advanced 3 Power on the GXV3674_HD FHD_VF 4 Start the browser when the network connection is up 5 Enter 192 168 1 168 in the address bar of the browser 6 The browser will ask for plug in or ActiveX if not installed otherwise it will get to Home page and start to show the video captured by the camera by default the camera enabled anonymous access 7 Click Configuration the browser will ask credentials to authorize configuration 8 Enter the administrator user name and password to access the Web Configuration Interface the default user name and password are both set to admin 9 The plug in can be downloaded from here http www grandstream com products tools surveillance webcontrl_plugin zip NOTE gt Please temporarily disable Antivirus or Internet Security Software and close all browsers when download and install the Grandstream
40. thenticate ID used by SIP proxy e Authenticate Password Authenticate password used by SIP proxy e STUN Server STUN server used to resolve NAT if have Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Firmware Version 1 0 2 12 Page 23 of 41 Last Updated 06 2013 dstream Innovative IP Voice amp Video e Steam Which stream used for SIP call e Preferred Vocoder Audio codec used for SIP call NOTE e Registration Expiration Registration expiration time default 3600 seconds e Local SIP Port Local SIP port default 5060 e Local RTP Port Local RTP port for media default 5004 e Auto on hook Timer Auto On Hook timer default 300 seconds e Disable Audio in SIP Call Checked to disable audio for SIP call e Enable Keep Alive Checked to enable help NAT resolution e Accept Direct IP Call Check to accept peer to peer IP call Accept Direct IP Call VW Enable White List Number Filter T Enable Dual way Audio Warning Mode SIP Proxy Compatibility Mode O Self define Warning Audio Upload Delete Note You must restart the device to apply the changes Phone List Phone Number Remark Name Remove 6179114110 Local Security Staff Add Note You must restart the devc2 to apply the charges White List Phone Number Remove 6175669300 Add Note You must restart the device to apply the changes Figure 8 2 SIP Setting Page e Enable White List Number Filter Check to
41. uration Page e As shown in Figure 15 2 user can configure the Motion Detection Region with related Start and Stop time to control the motion detection operation Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 33 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 dstream Innovative IP Voice amp Video Syslog Settings Page Troubleshooting This page allows user to enable the Syslog to help troubleshooting problems SysLog Settings Syslog Server syslog myserver com Syslog Level User Management Maintenance SMTP FTP Alarm Server Motion Detection Figure 16 Alarm Server Setting Page e Syslog Server Syslog server IP or Domain Name Syslog Lever Lever of syslog message sent to the syslog server None Debug Info Warning Error Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 34 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 am Innovative IP Voice amp Video Software Upgrade Software upgrade can be done via either TFTP HTTP or HTTPS The corresponding configuration settings are in the ADVANCED SETTINGS configuration page Software Upgrade via TTFP HTTP or HTTPS This page allows user to configure firmware upgrade Restart the device Restart the device Restart User Management Restore the device Maintenance Reset settings except IP address to factory default Restore FTP Firmware Upgrade and Provisioning Alarm
42. ut 100 240VAG 50 60Hz Casing IP66 compliant weather proof metal case Compliance FCC Part 15 Subpart B Class B EN 55022 Class B EN 61000 3 2 EN 61000 3 3 EN 55024 EN 60950 1 C tick AS NZS CISPR 22 Grandstream Networks Inc GXV3674_HD FHD_VF User Manual Page 10 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voice amp Video INSTALLATION GUIDE Minimum Recommended Computer System Requirement To install GXV3674 HD FHD VF you have to have a computer PC recommend The minimum recommended PC system requirement listed below Windows XP Windows Vista Windows 7 and Windows 8 CPU Intel Pentium 4 or higher 2 GHz RAM 1 GB 4 GB recommended for larger systems Support for DirectX 8 0 and above Configure the GXV3674 HD FHD VF via Web Browser The GXV3674 HD FHD VF has embedded Web server to respond to HTTP GET POST requests Embedded HTML pages allow user to configure the IP camera through Microsoft Internet Explorer 7 0 or above Firefox and Chrome plug in from Grandstream required e Download Plug in from Grandstream website http www grandstream com products tools surveillance webcontrl plugin zip NOTE gt Apple Safari is NOT yet supported and status pending gt Please temporarily disable Antivirus or Internet Security Software when download and install the Grandstream Plug in Software Grandstream Networks Inc GXV3674 HD FHD VF User Manual Page
43. wer cab from Grandstream Networks Inc Please install this add on when prompted by IE 3 How do you manually uninstall the Grandstream video viewer add on for IE Please follow these steps to uninstall the add on 1 Delete the GS ViewerX Control from C WINDOWS Downloaded Program Files directory 2 Delete GSNetClient all GS Replay exe GSViewerX ocx hi h264dec w all lik VoiceEngine dall dill and GSViewerX inffrom C WINDOWS system32 4 Why can t I access the GXV3674 HD FHD VF web configuration interface Q 1 Is your internet service down A 1 Connect a PC to the internet to test the connection Q 2 Are the PC and the device in different subnets A 2 Check the subnet mask and default gateway of the device and PC Q 3 Is there a conflict with another IP address A 3 Try to change the IP address of the device Q 4 Has the HTTP port been changed A 4 Contact the administrator of the device for more information 5 The GXV3674 HD FHD VF web configuration page is not displayed correctly in IE8 In IE8 Compatibility View might need to be enabled for the GXV3674 HD FHD VF web configuration page to load properly To enable compatibility view open IE8 click Tools Compatibility View Setting and add the GXV3674 HD FHD VF web configuration pages to the Compatibility View Grandstream Networks Inc GXV3674 HD FHD VF User Manual Page 38 of 41 Firmware Version 1 0 2 12 Last Updated 06 2013 andstream Innovative IP Voi