        BYC08HE Programming Heating Thermostat User Manual
         Contents
1.   LCD Clock Down    Display area  60 x 32 mm Up    Setting Unit  0 5  C step    Display resolution  0 1  C Power On Off      Inside sensor  NTC B 3380 10k  25degrees Clsius     Extra sensor  NTC B 3380 10k  25 degrees Clsius  length 3 meters     When the working temperature of thermostat is below 0 degrees or thermostat   s detected temperature is below 0 degrees  screen would  display as 0 degrees         Temperature control mode     According to the sensor setting of thermostat  there are three different control modes  enter the advance function to set    Internal control  IN   Only enable built in sensor temperature measurement  the temperature control is based on the built in temperature sensor  It  is suitable for the detection of air temperature or the room temperature    External control  OUT   Only enable external sensor to temperature measurement  the temperature control is based on the external sensor  It is  suitable for the detection of the heating body temperature    Dual temperature control  ALL   Temperature control is based on the built in temperature sensor and an external temperature sensor        over temperature protection   It is suitable for the detection of room temperature and heating body whether over temperature monitoring  If the  external sensor is over temperature  thermostat will shuts down the heater      Display three kinds of temperature    The thermostat   s main screen shows air temperature or room temperature when it is under IN or ALL temp
2. BYCO8HE Programming Heating Thermostat    User Manual      General     This thermostat is applicable to water system and electric heated system with high power  According to the preset temperature value   thermostat will automatically start or stop the controlled object  such as valve  heating floor  heating wall  electric heater etc   It will enable you to  live in an energy saving and comfortable living environment    e With the latest single chip computer control technology  the heating equipment is anti jamming and extremely stable    e Multiple time modes  5 2 6 1 7days  the heating equipment supports different temperature setting accordingly with 6 time modes daily   Users are free to choose manual mode or full automatic mode for different purposes      The clock would continue to run even if power was cut off and it will not affect the period setting value      Keypad locking function is designed to prevent the children from misusing                                                            Technical parameters  Manual mode Auto model Air temperture      Power Supply  85 250VAC 50 60 Hz Heating   The maximum switch power  2A 16A Floor temperture    Internal sensor measurement range  0   40  C  Measured values  Setting range  5   35  C  factory settings  25  C  Stage Socenos  5 Week    External sensor measurement range  0   95  C  vaie Sai i  g   j PRA alue for ettings values  Setting range  0   90  C  factory settings  50  C  Week or Stage System clock    Monitor type
3. L  gt Sat  gt dEF    The thermostat   s monitors displaying type is LCD segment displaying  There are some differences between the displayed value and practical  value     Please make reference to the specific figure                                                                                                                                                              m m no HL m L m                                     You can press m to switch the system parameters  At the same time press A or y to modify settings  Select a set value  If you do not       press the or v  the parameters would not be modified  If you want to save the data  you must go through all the functions then exit the  system menu                 Display Set the content Adjustment range The default value  temperature correction  5  C  5  C  2 5  C  AdJ Used to correct the sensor value  screen would show the value needed to be revised when adjusting  the revised    value will be displayed after 3 seconds   PrG The period time mode 5 2 6 1 7 5 2                                                                         5 2  Monday to Friday is set as the same  Saturday to Sunday is set as the same   6 1  Monday to Saturday is set as the same  Sunday is individually controlled   7  Monday to Sunday is set as the same   Antifreeze On  Enable   OFF  Disable OFF  LtP Low temperature protection  what is suitable for the water system To prevent the pipe from freezing at low  temperature   Sensor or temperature co
4. e panel  align this position    6  Close frame  the installation is complete                      
5. erature controlling mode  The AIR icon  would be lit  the vice monitor would alternatively display temperature value and current time every 5 seconds    When the thermostat is under OUT temperature controlling mode  the FLOOR icon would be lit   the main screen would display floor  temperature or the tested temperature of the external sensor location     When the temperature is under ALL temperature controlling mode  press and y the main screen would display floor temperature or the    tested temperature of the external sensor location  And the FLOOR icon would be lit  The main screen will automatically display air temperature    5 seconds later  Then the AIR icon would be lit     Operation Guide   On and off  3    Press    keys you can turn on or turn off the thermostat           The display would be as the left picture when turning off  a                       System time     You need to adjust system time when it comes to use at the first time How to set the system time  Keep pressing L for 5 seconds  it will enter  into the time setting  The current revisable object will flash and display  Press    and choose time you want to revise  week   hour   minute    press Aor V to modify the current setting  If you need to modify the previous parameters  please press CL key  After modified minute you    can press    to exit the system clock settings      Automatic   manual switch     Press m you can choose the manual mode or automatic mode    Manual mode  System will control tempe
6. n shows  You can use the D o back to the previous setting  HDW    The system   s default period is 5 2  For specific data  please see the following table  User can modify the period by entering into the programming  interface                                               5 2 mode ID P1 P2 P3 P4 P5 P6  Start time 06 00 08 00 11 30 12 30 17 00 22 00  Monday to Friday  Set value 22  C 15  C 15  C 15  C 22  C 15  C  Start time 06 00 08 00 11 30 12 30 17 00 22 00  Saturday to Sunday  Set value 22  C 15  C 15  C 15  C 22  C 15  C       For example When the system time is Friday 08 20 under automatic mode  display would show as  STAGE 2 and the setting temperature value  would be 15 degrees      Lock      Press key E MT for 2 seconds at the same time  the controller keypad would be locked  Screen would show    Press the    CL atthe same time for 2 seconds under the locked status  keypad would be unlocked      System setting     Warning  System setting is used to set some important parameters of the system  that   s only for professionals     operation  Do not make any improper modification by yourself  The item has already been debugged and tested by    professionals  there is no need to reset   Enter the system setting  Press  O  to switch on the thermostat when the unit is turned off  Within the next second please press Key M as    soon  you will enter into system setting   The system menu parameters in order of appearance  AdJ  gt PrG  gt LtP  gt SEn  gt Top  gt dt0  gt dt1  gt b
7. nnect correctly   5  Power supply box and the motherboard Coupling are opposite inserted  please mind the direction  6  Power supply box and the motherboard Coupling is broken  please don t overexert  Coupling length is 6cm  the installation must be  careful  If damaged  no warranty and replacement   2  Fault phenomenon   Display rupture   Reason solution  Display encounters hard objects or sudden force  no replacement and warranty       3  Fault phenomenon   Display a black screen  Reason solution  If the display surface temperature is too high  please note whether there is heater nearby  if so please remove        4  Fault phenomenon  Display ERO or ER1       Reason solution   ERO  If built in sensor is abnormal  please pay attention to whether the small black dot in temperature sensing window was damaged during  removal  ER1  The system is set in the dual temperature control  ALL  mode  or it is not connected with an external sensor  or the external sensor is  abnormal   5  Fault phenomenon  No pen on LCD  Reason solution  Please check whether the iron plate is deformation when installation  If it is deformation  please correct it        6  Fault phenomenon   No backlight  Reason solution  Please check whether backlight lamp connection is broken when removing in the panel        7  Fault phenomenon  Backlight always bright  Reason solution  1  The ON is set in the system menu bL 2  If it is damaged  please replace it        8  Fault phenomenon  Large deviation of measureme
8. nt temperature and the actual temperature  Reason solution  1  The thermostat should be installed at ventilated place  It can not be installed at the place in direct sunshine or nearby the       heater 2  Back connection screw is not locked  causing terminal serious fever  9  Fault phenomenon  Display 0 degrees  Reason solution  Itis normal if thermostat display 0 degrees when the actual environment is below 0 degrees                                                                               Dimension in mm     Wiring diagram    re   PS A    N f        ING     NS Pia N N   ac in 85 250v ac in 85 250v          Imax 2A 4   Imax 16A z   J    H1 WIRE DIGRAM          H3 WIRE DIGRAM                                        wogan                                                                                             Relay1 _Relay2  L   To boiler  IITE  Pee p  L Dom       extra sensor extra sensor    LOAD      Installation Diagram    1  Separate a box to start the installation  2  Using a screwdriver and gently pry the position as shown   separate panel and the iron plate  3  Separate coupler  please note the direction of lead   4  After the panel is separated  please pay attention to the  interior components of the panel  handled  with care and properly placed   5  Strip length  lt   9MM  Wiring up as picture  you must tighten the  terminal screws  the iron plate  screws can not be too tight to prevent iron plate to deformation  5  Plug in the join line  fasten the panel  Buckl
9. ntrol mode Peed QUT External IN  ALL Dual temperature control  sen IN  internal control  room sensor Out  external control  floor sensor ALL  double temperature double  control  the internal room temperature sensor  external sensor overheating protecting  External temperature sensor limit 40 80  C 50  C  9p The sensor is set to ALL  the temperature limit external sensor value  Internal sensor hysteresis 0 5 4  C ke  ae Built in temperature sensor hysteresis  External sensor hysteresis 0 5 5  C FE  at External temperature sensor hysteresis  Backlighting status puna ON OFF  bL OFF  Auto turn off after 5sec  Backlight lighting mode  can be set according to personal preference  Siat  si  tre powet OFF  off status at every time OFF  Sat On  the same as previous   Used to control the power state of the boot  deF Restore factory settings Restore factory settings To restore the default settings                        The common errors and solutions of the system      1  Fault phenomenon   There is no display       Reason  amp  solution   1  Power supply system is having problems or power is supplied incorrectly  please check if the inlet wire is normal   2  If the connection is not right  please wired up as the wiring diagram on the back side   3  Actual temperature is too low  please note the thermostat temperature range  If the temperature is lower than  5   C  the unit cannot  normally display   4  Power supply box and the motherboard Coupling is not connected correctly  please co
10. rature under the set value without any change  The set temperature is going to be the most comfortable  temperature  There would be no icon iC  or week  Stage displaying    Automatic mode  System would control temperature according to the preset temperature values in different time  The icon iC  will lit  which  means that the system is running under automatic mode  The week and Stage icon would alternately display every 5 seconds  1 7 is  systematic reuse  When screen shows WEEK  1 7 would display the values of the week  When screen shows STAGE  1 6 would display the  current values      Setting the periods of time modes    The periods setting can realize the control of temperature and time under automatic mode  Once setting up  the values could be saved and  reused in the thermostat forever    The thermostat can save three kinds of schedules  5 2   6 1   7  in 6 periods  One week for a cycle    Each data is saved as the start time  hours  minutes  and the temperature degree of this period  The end time of the period would be saved as the  start time of next period  You can also shut down a certain period according to your actual needs     Press the  A for 5 seconds  you will enter into the period setting  See the right picture following        Press button M to select the object you want to modify  the period start time  hours  minutes and  set temperature   press Aor Vito modify the corresponding value  If you want to turn off a period   please press vy until the OFF optio
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
TEMPERATURE RECORDER (0 ÷ 300°C)  Samsung HT-TXQ100 Kullanıcı Klavuzu  MARZ ATTACK SERVICES MANUAL  IBM 380Z Laptop User Manual  Bose SoundDock Original Digital System  MODELS PCIe-COM232-8 and PCIe-COM232  Samsung L300 manual de utilizador  Delta 138265 Instructions / Assembly    Sony CDX-52RF User's Manual    Copyright © All rights reserved. 