Home
Slimline Q5 Series - Prolight Concepts
Contents
1. and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA cable DMX cable requirements for DMX operation This fixture can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output see image below Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Please quote CABL10 2m CABL11 5m
2. the unit e Do not open the equipment and do not modify the unit e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again OPERATING DETERMINATIONS If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly stop use immediately Pack the unit securely preferably in the original packing material and return it to your Pro Light dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be car
3. CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split www prolight co uk Slimline Q5 Series User Manual 9 LeD DMX setup Notice Be sure to follow the diagrams below when making your own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR EN ROR EN OO RAN SORES OMT RE OO XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Q Pin 2 Negative 3Hot 3Hot Pin 3 Postive Special note Line termination When longer runs of cable are used Termination reduces signal transmission you may need to use a terminator on problems and interferance it is always the last unit to avoid erratic behaviour advisable to connect a DMX terminal _ resistance 120 Ohm 1 4 W between pin 2 Using a cable terminator will decrease DMX and pin 3 DMX of the last fixture the possibilities of erratic behaviour 3 pin Order ref CABL9O 5 pin Order ref CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diag
4. LED Slimline Q5 Series 5W quad colour LEDs RGBW RGBA User Manual Order codes LEDJ58 505 RGBW Black housing LEDJ58A 505 RGBW White housing LEDJ59 7Q5 RGBW Black housing LEDJ59A 7Q5 RGBW White housing Sail LEDJ59B 7Q5 RGBA Black housing LEDJ59C 7Q5 RGBA White housing Order ref LEDJ9O0C LeDJ WARNING Safety advice FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP e Before your initial start up please make sure that there is no damage caused during transportation e Should there be any damage consult your dealer and do not use the equipment e To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual e Please note that damages caused by user modifications to this equipment are not subject to warranty CAUTION KEEP THIS EQUIPMENT AWAY FROM RAIN MOISTURE AND LIQUIDS CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCKH IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from
5. O e Now press the 2 button and the white amber LEDs will come on the third digit 5 has been set The full DMX address setting has been changed e Now press the DMX MODE button to save the new address into memory e Set the DMX address on each fixture before plugging into the DMX controller e The IR remote cannot be used when the fixture s are being controlled with a DMX controller e The maximum IR transmitter distance is 10m Please make sure that you have the IR remote aimed directly at the front panel of each fixture to be programmed e If you do not press the DMX MODE button after you have changed the DMX address when you power down the fixture it will lose the address you have set www prolight co uk Slimline Q5 Series User Manual 8 LeD DMX setup Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 512 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures
6. ents red L green b blue A amber and F Q strobe The 3 digits after are the brightness setting from OOD 255 or the strobe speed from O 4 For example If you setr L b A all to zero your unit will have no LEDs lit up blackout lf you set r OOD to 255 and G b and A to zero your unit will show only red LEDs Press the ENTER button to confirm the setting and move to the next colour To exit out of any of the above options press the MENU button Built in program mode To access built in program mode press MENU until the display shows Fr on the LED display Press the ENTER button and use the UP and DOWN buttons to select between Pr OO Pr 2a Press the ENTER button and use the UP and DOWN buttons to select the speed between F O 5P 9 Press the ENTER button and use the UP and DOWN buttons to select the flash speed between F O F 4Y To exit out of any of the above options press the MENU button Slave mode Press the MENU button on the rear of the unit to show 5L ALI on the LED display and press the ENTER button to confirm the setting The unit will now run in sequence with the master unit To exit out of any of the above options press the MENU button Please ensure that all slave units are set to the same DMX channel mode as the master unit www prolight co uk Slimline Q5 Series User Manual 6 LeD Operati
7. ge the flash frequency 04 Sets the run speed use the and buttons to change the desired speed note only available in the colour change or colour fade modes 05 Sets the LEDs into DMX mode 06 Sets the LEDs into sound active mode 07 Sets the LEDs into slave mode 08 Sets the DMX address for the LEDs O9 Sets the LEDs colour then use the and buttons to change the brightness DMX address examples To set the DMX address 245 e Press the S button the red LEDs will come on you can now start to set the DMX address e Now press the 2 button the green LEDs will come on this means the first digit has been set at 2 e Now press the 4 button the blue LEDs will come on this means the second digit has been set at 4 e Now press the 5 button and the white amber LEDs will come on the third digit 5 has been set The full DMX address setting has been changed e Now press the DMX MODE button to save the new address into the memory Important notes Operating instructions Optional IR remote Order code LEDJ9OC To set the DMX address 002 e Press the S button the red LEDs will come on you can now start to set the DMX address e Now press the O button the green LEDs will come on this means the first digit has been set at O e Now press the O button the blue LEDs will come on this means the second digit has been set at
8. hannel mode 000 240 Master dimmer 0 100 241 255 2 3 channel mode 4 channel mode RGBW White 0 100 7 channel mode RGBW 5 e 5 7 www prolight co uk 4 channel mode RGBA Red 0 100 Green 0 100 7 channel mode RGBA 4 5 e 4 5 Blue 0 100 Amber 0 100 7 151 255 Slimline Q5 Series User Manual 5 LeD Operating instructions RGBW colour mix mode In this mode you can set the fixture to any colour and any brightness To access the colour mix mode press the MENU button on the rear of the unit to show r with 3 digits after on the LED display Press the ENTER button to confirm The r represents red L green b blue Li white and F D strobe The 3 digits after are the brightness setting from OOD 255 or the strobe speed from UY Y For example If you setr G 6 Li all to zero your unit will have no LEDs lit up blackout lf you set r OOD to 255 and L b and a to zero your unit will show only red LEDs Press the ENTER button to confirm the setting and move to the next colour To exit out of any of the above options press the MENU button RGBA colour mix mode In this mode you can set the fixture to any colour and any brightness To access the colour mix mode press the MENU button on the rear of the unit to show r with 3 digits after on the LED display Press the ENTER button to confirm The r repres
9. ion 7Q5 RGBA version 25 Lux 3040 753 337 186 184 25 Lux 7725 2280 945 535 335 O n n on a C m en u u Om 1m 2m 3m 4m 5m Om 1m 2m 3m 4m 5m www prolight co uk Slimline Q5 Series User Manual 3 LeD Technical specifications POWER INPUT POWER OUTPUT DMX OUTPUT DMX INPUT LeDJ 100 240V 50 60Hz FUSE T1A T2A 250V 616 MENU ENTER UP DOWN 01 LED display 04 IEC power input O7 3 Pin DMX input In the box 1 x fixture 02 Function buttons 05 IEC power output 08 Fuse T1A 250V 5Q5 1 x power cable amp 03 Earth point 06 3 Pin DMX output T2A 250V 7Q5 1 x user manual www prolight co uk Slimline Q5 Series User Manual 4 LeDJ DMX channel mode Operating instructions Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently nt To access the DMX channel mode press the MENU button on the rear of the unit to show fuu i on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the desired DMX address Now press the ENTER button to choose one of the 2 3 4 or 7 DMX channel modes use the UP and DOWN buttons and press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button 2 c
10. ng instructions Sound active mode To access the sound active mode press the MENU button on the rear of the unit to show SUODO on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from SHOO 5499 and press the ENTER button to confirm the setting Value 00 99 00 low 99 high To exit out of any of the above options press the MENU button Menu system RGBW Menu system RGBA Static colour mode Static colour mode Built in program mode Built in program mode PrOO Pr20 PrOO Pr20 Pr 508 RW P 09 GW Pr 10 RB Pr ii RGB Pr Ig RGW Pr 13 RBW Pr 14 GBW Pr 15 RGBW Pr I6 Colour change 15 colours I6 Colour change 15 colours Pr 11 Colour fade 15 colours 17 Colour fade 15 colours IB Colour change 4 colours IB Colour change 4 colours 19 Colour fade 4 colours 19 Colour fade 4 colours a 20 Colour change 3 colours P 2G Colour change 3 colours 5 Au SLAY uoo uo0 2CH 3CH 4CH 7CH 2CH 3CH 4CH 7CH AOD 1 A5 12 ROO IAS i www prolight co uk Slimline Q5 Series User Manual 7 LeDJ Optional IR remote functions Button functions 01 Sets the LEDs into power on or off modes 02 Runs the built in programs use the and buttons to go through the programs 03 Sets the LEDs to flash on and off use the and buttons to chan
11. peration and feature a 25 beam angle The 4 push button LED menu or optional IR remote allows easy access to the functions including DMX master slave sound active and stand alone e 5x 5W quad colour LEDs 5Q5 e 7x 5W quad colour LEDs 7Q5 e Beam angle 25 field angle 40 e AOQOHz refresh rate e DMX channels 2 3 4 or 7 selectable e Static colour colour change colour fade auto run sound active and master slave modes e 0 100 dimming and variable strobe e Bracket allows for multiple rigging or floor standing applications e Rubber feet allow the panel to sit flat on the floor for uplighting e A push button menu with LED display Specifications Slimline 5Q5 e Side entry XLR and power connections Power consumption 38W e IEC power input output Power supply 100 240V 50 60Hz e 3 Pin XLR input output Fuse T1A 250V Convection cooled Dimensions 224 x 202 x 99mm e Optional IR remote LEDJ90C Weight 2kg Order codes LEDJ58 RGBW Black housing e Linkable with the Slimline 12Q5 Slimline 7Q5 45W 100 240V 50 60Hz T2A 250V 224 x 202 x 99mm 2 5kg LEDJ59 RGBW Black housing LEDJ59A RGBW White housing 202mm 99mm 7 LEDJ58A RGBW LEDJ59B RGBA Black housing White housing x Z S j LEDJ59C RGBA White housing O 7Q5 RGBW version N N 25 Lux 7725 2280 945 535 335 3 3 er EE a Om 1m 2m 3m 4m 5m 505 RGBW vers
12. ram below details the correct cable conversion F B A E 5 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR socket 3 pin XLR socket Pin 1 GND screen Pin 1 GND screen 8 Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal Pin 4 N C Pin 5 N C www prolight co uk Slimline Q5 Series User Manual 10 LeD WEEE notice Correct Disposal of this Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries SS with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with o
13. ried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS This lighting fixture is for professional use only it is not designed for or suitable for household use The product must be installed by a qualified technician in accordance with local territory regulations The safety of the installation is the responsibility of the installer The fixture presents risks of severe injury or death due to fire hazards electric shock and falls Warning Risk Group 2 LED product according to EN 62471 Do not view the light output with optical instruments or any device that may concentrate the beam WARRANTY One year from date of purchase If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns and electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and or property www prolight co uk Slimline Q5 Series User Manual 2 LeDJ Slimline Q5 Series Product overview amp technical specifications Housing 5W quad colour LEDs the Slimline Q5 Series give smooth colour mixing from rich saturated hues to subtle pastel shades These units have rugged all metal housings and measure only 99mm in depth for easy transportation and installation They are also convection cooled for silent o
14. ther commercial wastes for disposal CE fe www prolight co uk Slimline Q5 Series User Manual 11 LeD Optional accessories Please contact your local retailer to purchase these accessories 00000 SIO 0O OO 00O Optional IR remote Optional Quad Case Holds 4 x fixtures Order code LEDJ90C Order code CASE71 To keep up to date on the latest accessories and product range additions please visit www prolight co uk LeD www prolight co uk Slimline Q5 Series User Manual 12
Download Pdf Manuals
Related Search
Related Contents
Brodit ProClip 654993 708930-0 G7 User manual - Export.indd Bowers & Wilkins DM 309 User's Manual Le Réseau fiscalité - Union des villes et communes de Wallonie Betriebsanleitung MCH-6 Minox MX Operating Instructions Installation Instruction - Maytag Commercial Laundry 取扱説明書 (22.70 MB/PDF) Copyright © All rights reserved.
Failed to retrieve file