Home

Shanghai Diebold Security Equipment Co., Ltd.

image

Contents

1. and G1 710 need to turn the knob clockwise to open the door A Note The time interval between two button pressings shall not exceed 20 seconds otherwise the LCD screen will turn off automatically and the current operation will become invalid toctose Close the container door Model G1 410 G1 510 G1 610 and G1 710 need to turn the knob counterclockwise 4 first and turn the main key counterclockwise 4 to its proper position the key stem shall assume a horizontal position to lock the container Then pull out the main key IEBOLD i De TO OPEN IN EMERGENCY The override key can be used in combination with the main key to open the container in emergency Disk board Override keyhole Figure 6 Turn the LCD disk board counterclockwise as the above figure shows and remove it from the panel You will see the override keyhole behind the disk board Insert the override key into its hole and insert the main key into the main lock keyhole Turn the override key counterclockwise 4 followed by turning the main key clockwise to open the door A Note The override keys are for emergency use Please keep them in a safe place Don t place them in this container MIEBOLD a TO REPLACE THE BATTERIES When the prompt 4 is displayed on the LCD screen during you are operating the container this indicates that the batteries are low and need to be replaced with new ones in time Replacing Method Pu
2. go out after 20 seconds Turn off the function for shock alarm The shock function can be turned off by any of the following operations Input a correct combination Input a correct combination in the process of changing combination Press the combination setting button TO PESENT INFORMATION O If you provide the following information to service people you will get quicker assistance Product Serial Number See label on the right side of product Product Model Purchase Invoice of Product Maintenance Guarantee 11 CUSTOMER SUPPORT HOW TO OBTAIN ASSISTANCE answer when using this product please take one of the O If you have any question that this User s Manual cannot following approaches to obtain assistance L To call SDSEC Technical Advisory Service at 86 21 6480 9355 13386290300 ext 6320 6321 6322 or 6323 L To send questions through SDSEC s fax response system to get product specifications Fax 86 21 6480 3291 O To contact our local dealers or distributors O To visit our website Http www diebold cn 12 Al j SFEBOLD ELECTRIC PARAMETERS AND ACCESSORY LIST Work power 4 pieces of 1 5V AA batteries Voltage limit 10V DC Voltage range 4V 7V Current during sleep lt 2pA ACCESSORY LIST O User s Manual 1 piece 1 piece for each upper door and lower door of model G1 810S O Main k
3. user code Please replace the battery compartment cover after completion of changing the user code 5 With the door opened enter your new user code 2 8 numbers followed by pressing GD button The LCD screen will flash your new user code three times and turn off by itself 6 Turn the main key counterclockwise 4 to extend out the locking bolts to lock the container door Model G1 410 G1 510 G1 610 and G1 710 need to turn the knob counterclockwise 4 first New user code has been successfully set up A Please operate the container with your new user code according to the above steps 1 3 and 6 to confirm that your new user code can open the container door Close the container door turn the main key counterclockwise te and pull out the main key Now your user code has been changed successfully A The time interval between two button pressings shall not exceed 20 seconds otherwise the LCD screen will turn off automatically and the current operation will become invalid IEBOLD a TO OPEN CLOSE To open LJ Step 1 Insert the main key into the main lock keyhole See Figure 3 and Figure 4 in the panel Step 2 Enter your user code and the number you entered will be displayed on the LCD screen See Figure 2 Step 3 Press the GD button and the prompt ef will be displayed on the LCD screen See Figure 2 Step 4 Turn the main key clockwise Model G1 410 G1 510 G1 610
4. Compartment Figure 1 2 DEBOLD SAFE WITH ELECTRONIC COMBINATION LOCK Keypad Knob Door Body Figure 1 3 OT ooo a Inner door le Pol Inner door lock Figure 1 4 IEBOLD i o BUTTONS AND LCD SCREEN Buttons Function O De O The ten numeric buttons from 0 to 9 are used to enter the combination GD The button is used to disable the combination display and clear the entered combination GD The button GD is used to confirm and complete the combination entering 1 2 3 4 Os Sotto EP HHHBH8H8 Figure 2 LCD Prompts used to display or indicate the entered combination the unlocking delay time and various statuses 1 The prompt s will be highlighted to indicate that changing the user code is under process 2 The prompt amp will be highlighted to indicate that the electronic combination lock is locked 3 The prompt amp will be highlighted to indicate that the electronic combination lock is unlocked 4 The prompt will be highlighted to indicate that the batteries are low and the user should replace them with new ones e ___ will be displayed to indicate that the keypad is under dead lock and the code cannot be entered now e error 1 error 2 and error 3 will be displayed respectively to indicate an incorrect u
5. DIEBOLD SHANGHAI Shanghai Diebold Security Equipment Co Ltd Thank you for choosing Shanghai Diebold LCD electronic lock container In order for you to use this product well please read this User s Manual carefully before using this product This is a new generation of LCD electronic lock container series developed meticulously by Shanghai Diebold with succinct appearance and reliable structure Patented bolts and their locking mechanism have super anti attack ability All functioning indicators on LCD are clear to read and make it easy to operate Blue backlit display is pleasant to users Shanghai Diebold Security Equipment Co Ltd SDSEC is a joint venture with foreign partner the world famous multinational corporation Diebold Inc and is licensed to use the Diebold patents and the world famous trademark lt EBOLD For over one hundred years Diebold has been the world market leader in security products and financial equipment industry SDSEC regards high tech high standard and high quality as its basis and excellent service and good reputation as its root Note This User s Manual applies to models G1 110 G1 210 G1 310 G1 410 G1 510 G1 610 G1 710 G1 810S No B 05036 IEBOLD DIEBOLD De A First Time Operation Ll Turn the LCD mounting disc counterclockwise and remove it from the panel Figure 6 P 8 in User s Manual Locate the override keyhole behind the disc Insert the overri
6. de key Figure 3 P 5 in User s Manual into its keyhole and turn it counterclockwise to the end then insert the main key into the main lock keyhole Figure4 P 5 in User s Manual and turn it clockwise to the end to open the door Model G1 410 G1 510 G1 610 and G1 710 need to turn the knob clockwise to open the door Ll Take out four AA batteries from inside the container Locate the battery compartment in the back of the door and remove the compartment cover Figure 5 P 5 in User s Manual Install the batteries into the compartment as per polarity marks indicated inside the compartment and replace the cover To download our English User s Manual please visit our website www diebold cn JEBOLD te CONTENTS Illustrated LCD Electronic Lock Container Button and LCD Screen Key and Knob Panel and Battery Compartment Operations To Operate for the First Time To Open Close To Open in Emergency To Replace the Batteries To Change the Number Entered To Use Spyproof Function Beeper Indication Trouble Shooting To Use Alarm Function Customer Support Electrical Parameters and Accessories List cee cee eee Maintenance Guarantee 13 14 DEBOLD SAFE WITH ELECTRONIC COMBINATION LOCK Body eee a Koyo LCD Screen Door Figure 1 1 Body Inner door Inner door Bolt lock Door J Shelves Emme l Battery
7. ey 2 pieces 2 keys for each upper door and lower door of model G1 810S O Override key 2 pieces 2 keys for each upper door and lower door of model G1 810S Q Conformity Certificate 1 piece L Bolt down hardware 2 Sets O AA batteries 4 piece 4 piece for each upper door and lower door of model G1 810S Ll Inner Door Key 2PCS Only for Model G1 310 G1 410 G1 510 G1 610 G1 710 and G1 810S 13 _DEBOLD MAINTENANCE GUARANTEE This product is guaranteed for one year from the date when it is purchased This guarantee only applies to the product quality problems occurring under normal operating conditions except man made damages e g damages incurred from improper operation or carelessness damages incurred from assemble or disassemble repair and improper installation without permission from our company and damages incurred from force majeure The original invoice that is issued when this product is purchased must be presented when guaranteed maintenance service is provided Maintenance Record Calling Date Service Date Trouble amp Cause Action amp Result Repairer DIEBOLD tl TO AFFIX THE INVOICE Please affix the invoice or copy for this product in this place in order to present it to our customer support personnel and get assistance without delay DIEBOLD tt MEMO
8. ser code is entered once twice and three times IEBOLD a KEYS Keys Description Main Key fe Override Key Knob Figure 3 PANEL AND BATTERY COMPARTMENT Main Lock Keyhole LCD Screen Figure 4 Panel User Code Changing Button Mark Le Ail GERS a Compartment Cover Moving Direction Compartment Cover Removing amp Replacing Directions Figure 5 Removing the Compartment Cover MIEBOLD a TO OPERATE FOR THE FIRST TIME If this product is put into use for the first time please open the safe according to TO OPEN IN EMERGENCY P 8 and install the batteries according to TO REPLACE THE BATTERIES P 9 Then change the factory code according to the following procedures 1 Insert the main key See Figure 3 of the container into its keyhole in the panel followed by entering the factory code 1 5 9 2 Press the GD button and the prompt ef will be displayed on the LCD screen See Figure 2 3 Turn the main key clockwise Model G1 410 G1 510 G1 610 and G1 710 need to turn the knob clockwise sk to open the container door 4 Locate the battery compartment in the door back Remove its cover according to Figure 5 Press the user code changing button The prompt See Figure 2 will be displayed on the LCD screen with two beeps to indicate that its in process of changing the
9. sh and remove the battery compartment cover according to Figure 5 Take out the old batteries and install the new ones properly into the compartment as the polarity marks show Put and push the compartment cover into place A Special Recommendation Under the circumstance that you won t be using this container for a long term it is recommended that you should remove the batteries and reinstall them whenever you want to use it again Your user code won t be lost TO CHANGE THE NUMBER ENTERED If a wrong number is entered when you are entering the user code press the GO button to clear the last number entered and continue to enter the right numbers Repeat pressing the button to clear all numbers entered one by one until no number is displayed on the LCD screen TO USE SPYPROOF FUNCTION Press the G gt button before entering your user code and the _ prompt will be displayed on the LCD screen instead of your user code After completion of one operation this function will exit for next operation and the user code will be displayed on the LCD screen again MIEBOLD a BEEPER INDICATION One beep may indicates that One button is pressed or e The user code has been successfully changed after the numbers displayed on the LCD screen flash three times at completion of changing the user code or e The correct user code has been entered the electronic combination lock is unlocked while the E is displayed on
10. the LCD screen or e The batteries have been replaced Two beeps indicate that it is in process of changing the user code after pressing the user code changing button while the prompt Qs is displayed on the LCD screen Three beeps indicate that an incorrect user code is entered Six beeps indicate that some failure has happened to the circuit TROUBLE SHOOTING No Trouble Cause Solution No batteries installed 2 Install the conformity batteries No reaction 1 upon button Batteries installed incorrectly with refer to TO REPLACE THE pressing wrong polarity placement or BATTERIES non conformity batteries Wrong key or incorrect insert Use the right key see Figure 3 direction and insert it in the right direction Replace the old batteries with Low batteries new conformity batteries refer to Lock TO REPLACE THE BATTERIES 2 cannot Incorrect user code Enter the right user code open Refer to P 7 TO OPEN IN EMERGENCY and unlock the safe by a override key and a main key With the door open perform step 4 amp 5 to set up your new code according to P 5 TO OPERATE FOR THE FIRST TIME User code is forgotten 10 IEBOLD i a TO USE ALARM FUNCTION O Turn on the function for shock alarm Recommend to press any numeral button then G button to turn on the shock alarm function or press any button except G5 button to turn on this function and LCD screen will

Download Pdf Manuals

image

Related Search

Related Contents

SoftWall Finishing Systems SW322318030 Installation Guide  2 - Canon  Bedienungsanleitung 8in1 Touchscreen Universal  Samsung GT-E1205I User Manual(OPEN)  Samsung Galaxy Y Duos  Benutzerhandbuch für Bootsanhänger  Philips PDCC-JS-JW-0734 User's Manual  Samsung BCD-252MMGR 用户手册  Guide to the MVI56-WA-EIP User Manual  Untitled  

Copyright © All rights reserved.
Failed to retrieve file