Home

User manual - Wassermann Dental

image

Contents

1. buttons as described below to set the function This allows you to check and or change stored values 6 1 2 Setting the time eS me WAPO MAT e Omm 8 O O 9 EE eG WASSERMANN DENTAL MASCHINEN Press and hold Time 2 then press Start Stop 9 once The first character on the display 8 flashes to indicate that the value can be changed by pressing Set Point 4 or True Value 5 while Time 2 is held on Release all three buttons to store the changed value Store the value by simultaneously pressing Polymerisation 1 and Set Point 4 For the second value press and hold Time 2 again then press Start Stop 9 once The second character on the display flashes Follow the same sequence as above The procedure is the same for the third display character Each change needs to be stored If Time 2 is pressed and held and Start Stop 9 pressed a fourth time the total of the three individual times is displayed Times assigned the value zero 0 are ignored 1 WASSERMANN DENTAL MASCHINEN 6 1 3 Setting the temperature Press and hold Temperature 3 then press Start Stop 9 once The first character on the display 8 flashes to indicate that the value can be changed by pressing Set Point 4 or True Value 5 while Temperature 3 is held on Release all three buttons to store the changed value The value is stored by simultaneously p
2. interference with the unit by unauthorized persons Spare parts and accessories Spare parts Item no Name 170601 Button cover 170625 Cover compl 392008 Rubber foot 32 x 32 H6 black 511091 Rocker switch green Accessories Name PVC hose 19 x 4 1500 mm long Hose protector 20 32 x 12 2 Kalk Ex 1000 ccm 320030 322017 655002 id WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 1 Repairs Servicing or repairs to the equipment must only be carried out by trained technicians Only original Wassermann spares are to be used Responsibility for the product is voided if altered by unauthorised persons or if inappropriate components are installed 10 Technical specifications 170998 WAPO MAT Voltage 220 240 V 50 60 Hz Power consumption 8A Output 1800 W Capacity 18 5 L Overall dimensions Width 330 mm Height 460 mm Depth 530 mm Weight 18 5 kg Noise emission lt 70 dB A Li We reserve the right to make technical changes FI WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 11 EC CONFORMITY CERTIFICATE in accordance with 2006 95 EG low voltage guidelines and 2004 108 EG EMV guidelines and 98 37 EG Machinery guidelines Manufacturer WASSERMANN Product description Polymeriser for dental Dental Maschinen GmbH applications Rudorffweg 15 17 D 21031 Ham
3. the water level is always above the white plastic ring inside tank otherwise the heater will shut off automatically On addition there is a safety step the heating stops automatically when the temperature of the heating is higher than 99 C Li If the equipment is not to be used for an extended period disconnect the power plug from the mains switch WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 Use 6 1 Operation Turn on the main switch green rocker switch N Check the water level the orange low water light 7 should not be on or flashing Place the prepared moulds in the holder Set the desired polymerisation time 2 see 6 2 Set the desired temperature 3 see 6 2 Press the Start Stop button 9 to start polymerisation The yellow LED 6 comes on during heating N DOO The unit switches off automatically at the end of the polymeriation time Note The red LEDs indicate the active controls N Polymerisation 1 d y 1 l 8 LED display Q Time 2 u a 4 Default Plus Temperature 3 e ie m o 5 Current Minus O Heating 6 aT 9 Start Stop Low water 7 WASSERMANN DENTAL MASCHINEN Es WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 1 1 Polymerisation choice of 3 times and 3 temperatures The Polymerisation 1 and Set Point 4 LEDs must be on but not Start Stop 9 Use the
4. 1h 30 m 95 C 11 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 7 Troubleshooting Correcting errors Fault Likely cause Likely solution WAPO MAT does not heat up Dirty level sensor Clean level sensor Water level too low Add water Water level LED comes on and warning tone sounds Dirty level sensor Clean level sensor Water level too low Add water until red LED goes out and tone stops Multi function display not working correctly Variations in mains voltage 220 240 V 50 60 Hz Turn of main switch and turn on again in about 1 minute Multifunction display shows A Water temperature above 100 C A3 means 103 C faulty temperature sensor faulty control board Turn off the water supply switch off the unit completely contact service Multifunction display shows F 1 Short circuit Faulty electrial component Turn off the water supply switch off the unit completely contact service Multifunction display shows F 2 Faulty temperature sensor Turn off the water supply switch off the unit completely contact service Li If the above measures do not solve the problem contact your dental depot or our service department MUS WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 Maintenance 8 1 Cleaning The equipment should be cleaned regularly ie clean every 4 weeks with Kalk
5. 2 FORYOUR SAEETY i ee eee eoe ee eu reete eere e e pensa 3 2 1 YOUR USER aeska Eri Se 3 2 2 SAFETY GUIDELINES 4 2 3 RESPONSIBILITY FOR OPERATION AND 4 3 APPLICATION ccsccissssscsiscsssscsocecscesacssssessssesssecscctecscecdessesssscsuacscesesdeseces 5 4 BEFORE YOU START cscssssssssssssscsssscssccscsssscssssssscscccccccccssccssessees 5 4 1 UNPACKING TRANSPORT 5 4 2 SET UPY STORAGE 2 8 Se ee een 5 S ERR EE EEE 6 AE 7 6 1 OPERATION PM 7 6 1 1 Polymerisation choice of 3 times and 3 temperatures esses 8 612 Setting th me escena ere Heb deter re ee ER Pete peii perte e 8 6 1 3 Setting the temperature ne Oe oce e OR I UR reddet 9 6 2 STORING SETTINGS ein ea rese ete arbe ee pedea epe nece e n 10 7 TROUBLESHOOTING CORRECTING ERRORS 11 8 MAINTENANQUG PE ee ee eee eoi EE eee seeker etra ERR isos 12 8 1 uis Ich 12 8 2 MAINTENANGE 13 9 WARRANTY de cose cocessssdusenssescececeta
6. Ex to guarantee problem free operation Quantity approx 300ccm Kalk Ex per full tank 18 5 litres water If there is considerable limescale present increase the amount of Kalk Ex appropriately The initial supply of Kalk Ex comes with the machine Clean the level sensor white plastic ring in the tank using a nailbrush for example Clean the outside of the unit and any accessories with a sponge and or a soft cloth and mild detergent The model plate must always be legible and must not be removed Warning Leave KALK EX to work for a maximum 12 hours Then drain the tank and rinse thoroughly Warning Please clean the water level sensor every 14 days with a brush water level sensor aahaaannan gt gt r YYY r un WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 2 Maintenance The WAPO MAT does not require any special maintenance You just need to keep it clean 9 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our Service department Your polymeriser should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed The warranty does not cover damage caused by improper use external mechanical causes transport damage or
7. L MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com
8. User manual Polymerisation unit WAPO MAT in Figure 1 WAPO MAT C Die Basis f r Ihr Labor is WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann dental equipment incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this instruction manual carefully before you connect this device and start work and operate the device according to the recommended guidelines The operation safety and the functionality of this device can only be guaranteed if you follow both the general safety guidelines and the applying laws to prevent accidents as well as the precautions given in this instruction manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using this device has read and understood this instruction manual Keep this instruction manual in a safe place where it can be referred to as required at any time Company address Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Germany Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 E mail info wassermann dental com URL http www wassermann dental com cn WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Contents 1 OO WLUL HN OC 3
9. burg Model WAPO MAT 170998 Applicable standards DIN EN 61010 1 2004 DIN EN 61000 6 3 2005 DIN EN 61000 6 1 2002 DIN 45635 1 1984 DIN EN 60335 1 2007 Hiermit wird best tigt da die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erkl rung wird ung ltig falls die Maschine ohne unsere Zustimmung ver ndert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communit Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta maquina anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg 20 07 2007 Company stamp Signed Wilfried Wassermann 955 N GMBH Fu ray Qe oe ENAN Ham we pudort Managing Director WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTA
10. e it is connected to the correct power supply Disconnect the power cord before carrying out maintenance or cleaning work 2 3 Responsibility for operation and damage The responsibility for operating the equipment lies exclusively with the owner or user if said equipment is incorrectly serviced maintained or altered by persons not employed by an authorized dealer or if the equipment is used in a manner contrary to its specified purpose The equipment must be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the non observance of these instructions Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions Li Ensure that this user manual is accessible at all times and has been read and understood ae WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 3 Application The WAPO MAT is designed for water bath polymerisation All readily available plastics can be polymerised fully automatically slowly up to 12 hours and at high temperature 95 C Only use the device for this type of application 4 Before you start 4 1 Unpacking Transport Remove the packing materials and place the unit on a firm level surface Check the accessories are correct see 8 4 When moving the unit ensure that you have disconnected th
11. e power cord Use appropriate packing materials to avoid accidental damage 4 2 Set up Storage Set the machine up on a level surface Use the clip to attach the drain hose supplied firmly to the housing to ensure there is adequate drainage Always set up the equipment with sufficient space around it for working and servicing take its dimensions into consideration Do not set it up out of doors f the unit is to be stored for an extended period protect it from moisture and dust We recommend installing the polymeriser directly to the Li drainage system because the water draining from it can be very hot approx 95 C This also makes it much easier to empty the tank completely for cleaning for example de WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 5 Start up Plug in the power cable 220 240 V 50 60 Hz Fill the tank with water up to the white plastic ring max 18 5 litres Turn on the main switch green rocker switch The unit starts heating up immediately to the last stored temperature When the desired temperature is reached the yellow LED goes out and the unit is ready for use N Use heat resistant gloves when working with the WAPO MAT The WAPO MAT has a dry run cut out in order to prevent the heater burning out when there is insufficient water in the tank orange LED A warning signal also sounds while the program is running Make sure that
12. ressing Polymerisation 1 and Set Point 4 For the second value press and hold Temperature 3 then press Start Stop 9 once The second character on the display flashes Follow the same sequence as above Die Basis f r Ihr Labor 3 e Wapo MaT e 4 Q 463 4 3 WO 9 WASSERMANN DENTAL MASCHINEN Nes 4 The procedure is the same for the third display character Each change needs to be stored 5 If Temperature 3 is pressed and held and Start Stop 9 pressed a fourth time the first of the three individual temperatures is displayed dide WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor All recommendations for the use of this equipment whether in the form of verbal or written instructions or examples are based on our own experience and testing and can only be regarded as guidelines 6 2 Storing settings Individual settings can be stored by simultaneously pressing the Polymerisation 1 and Default 4 buttons When you store a setting a YES appears on the LED display The old setting is overwritten each time you store a new one Note You can return to the Wassermann default settings by pressing Polymerisation 1 and Current 5 simultaneously When you store them by pressing Polymerisation 1 and Plus 4 this is confirmed by a YES on the display Polymerisation default settings Time Temperature 6h 30 m 70 C 0h 00 m 0 C
13. vectecse 13 SPARE PARTS AND ACCESSORIES ecce eee eese eee eee eee eee 13 9 1 RM 14 10 TECHNICAL SPECIFICATIONS ccccccccccscsscsssssssssssssssseees 14 n WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 Features The well proven WAPO MAT polymeriser now with an easy clean multifunction display is a very compact tabletop unit designed for slow high temperature polymerising in a water bath Up to 9 moulds can be cured fully automatically during each polymerisation procedure The unit s stainless steel housing and tank guarantee a long service life It also has a safety cut out to protect the heater in case the water level drops too low 2 For your safety 2 1 Your user manual Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application Important safety symbols used in this manual Warning A This is a warning of risk situations and dangers Failure to observe this warning could be life threatening These warnings must be heeded Information il This symbol draws your attention to specific features which should be noted A WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 2 2 Safety guidelines This equipment is designed for 220 240 V 50 60 Hz A Make sur