1. ADVANCED DRUG KIT INFORMATION BOOKLET PLEASE READ BEFORE USE OR WARRANTY MAY BE VOID INTRODUCTION The following booklet is a users guide to using the NEANN ADK Advanced Drug Kit This kit has been selected by the Ambulance Service Of N S W under tender document ES 02 for introduction throughout the State of N S W Officers need to read this booklet carefully before setting up and using the ADK E NW Qu Hm aun wee qs un EQUIPMENT LAYOUT GUIDES The ADK has been designed to comply with the current equipment list provided by the Ambulance Service Of N S W all in a neat well laid out user friendly manner designed to remove the need of SEARCH amp SELECT ACTIVITIES This layout has specifically been designed to achieve the following Items of similar use have where possible been grouped and stored together Most equipment has been given it s own pocket elastic or division wherever possible to ease and reduce time spent on equipment checks and accessing equipment Divisions and elastics are designed for quick and easy access to all items of equipment essential in an emergency Equipment storage and pocket layouts have been specifically designed to allow easy viewing and access as soon as the bag is opened There are no hidden areas Equipment checks are easy and fast as missing equipment stands out It is therefore REQUIRED that the following layout guides be used for the setting up of y
2. EAL KIT ATTACHMENT lt was recognised that only a small number of crews will require the Endotracheal Kit and to build an external pocket would get in the way of most crews by increasing bulk of the ADK lt was also recognised that there is a need to have one standard ADK throughout the Ambulance Service Of N S W that can be used by all levels of qualification The ADK therefore comes with 3 clips for securing an Endotracheal Kit When not required the clips are secured out of the way by elastic and a velcro strap A separate presentation and booklet is provided on this Endotracheal Kit Attached CD relating to the Endotracheal Kit used by the Ambulance Service Of N S W ZIPPER LiFTING TAB To assist in opening the ADK the ADK comes with a red lifting tab on the lid This will help prevent the zipper from jamming during opening and closing and will prolong the life of the zips Lifting Tab VEHICLE STORAGE amp REMOVAL The ADK is designed to be stored in all Ambulance Service Of N S W vehicles The ADK needs to be stored in the vehicle storage unit with the Sharps Container facing outwards A red pull tab is provided to assist with the removal of the ADK out of the storage unit It is NOT to be used as a lifting tab Red Removal Tab LAYOUT GUIDE A layout guide for equipment storage in the kit has been provided to assist Officers in maintaining the correct equipment storage lt is found unde
3. it s new look and to remove scuff marks Nifty Spray amp Wipe can be used e lt a Tm Vironfrie Is Used Both Internally And Externally CLEANING INSTRUCTIONS All fabrics used in the ADK are designed to comply with the Australian Standards on Laundry Practice AS 4146 1994 for the removal and killing of HIV Hepatitis B and Vegetative Organisms A cleaning program that complies with the Australian Standards is available directly from RAPP Australia Pty Ltd for cleaning blood vomit and other substances off the ADK For those wishing to undertake in house cleaning at you own risk including risk to warranty some basic guidelines are listed below e he cleaner in keeping with normal practices should put on personal protective equipment such as gloves safety glasses face masks etc e Small areas of contamination Blood Soak by placing a wet sponge on stain immediately after contact If available an antibacterial solution Virkon should be added to the water Repeat as necessary then gently clean off residual stains with light spray of Nifty Allow to dry thoroughly before use Vomit Gently sponge with hot water immediately after contact If available an antibacterial solution Virkon should be added to the water Repeat as necessary then gently clean off residual stains with light spray of Nifty Allow to dry thoroughly before use e Larger areas of contamination Initially Remove resu
4. ll allow for the IV Access equipment to be placed close to the patient when work areas near the patient are too limited to allow for close placement of the ADK A lifting tab is provided on the bottom of the panel to assist in the panel s removal Lifting Tab To Assist removal Of The IV Access Panel REMOVABLE SHARPS CONTAINER A removable Sharps Container Panel which velcros into place has been designed to allow for the Sharps Container to be placed close to the patient when work areas near the patient are too limited to allow for close placement of the ADK The removable sharps container will also allow for varying types of Sharps Containers and for future expected changes Sharps Conataner Removed From Main Kit Sharps Contaner Attached CARRY HANDLES The ADK carry handles come with a thick foam padded section to make carrying the bag comfortable even over long distances Velcro closure to join the handles has been chosen for speed and ease of use The carry handle design will allow the ADK to be picked up and carried short distances in urgent situations without the need to zip the ADK closed Carry Handles uie e NN mu um A nu a aa SHOULDER STRAP A detachable quick release ergonomically designed non slip shoulder strap offers an additional carrying choice The shoulder strap can be either attached or detached for storage Shoulder Strap Shoulder Strap Stored Attached ENDOTRACH
5. one 03 5284 0222 Fax 03 5282 4892 AUSTRALIAN MADE NEANN ADK ADVANCED DRUG KIT USER SURVEY To help RAPP improve the product amp training information supplied please complete the following survey by circling the appropriate number next to the question Additional comments are most welcome Name Loe c ccc cccccccccccecccucucucuvuvavuvuvuvavavavavanans i E O o O c O O Station IPAE gt S E gt Q oO O gt O oO x lt gt A lt O gt LLI Contact Phone number cR 1 Was the powerpoint training package adequate 1 2 3 4 5 6 Sein ENIRO TOT o o oo ER A 2 Was this information booklet adequate 1 2 3 4 5 6 Sen TER T UU 3 Are you pleased with the manufacturing quality 1 2 3 4 5 6 Comment tico 4 Does all the equipment fit properly into the kit 1 2 3 4 5 6 eei t mmm mmm mt mmm um mmm mmm 5 Is eguipment easy to access 1 2 3 4 5 6 Sess TEN em 6 Does the kit work well in the field 1 2 3 4 5 6 Comment sssessseessen n nennen vaas enne maneas sae sas ses ssse sees sse sse sss sas esae ns 7 Are you pleased with the kit overall 1 2 3 4 5 6 Comment ccc cece cceccceccccccucceucceueceueteuetauecanetanetanteueteneteuesnneteuetnnetenenanngs Once complete please fax to the NEANN Office on 03 5282 4892
6. our kit to obtain maximum function of the ADK and to allow for a standard layout of kits on all Ambulances through out the State of NSW NEANN ADK LAYOUT GUIDE PLEASE NOTE This layout guide must be strictly adhered to This will ensure a standard configuration throughout the whole of the Ambulance Service Of N S W Overloading of the ADK may potentially result in excessive weight placing Officers at risk of injury Incorrect placement of equipment WILL damage the elastics and pockets For OH amp S reasons all equipment must be stored in it s original packaging Alcohol Swabs Jelcos Reflux Valves NaCl x8 x4 x4 A Torniquet x 2 i Opsite x6 Nacl x 1 Shaver x 1 Syringe 10 ml x 6 Micropore 129 61 1 Syringe 3 ml x 4 Gauze x 1 Drawing Up Syringe 1 ml x 4 Needle x 5 21 g Needle x 3 Drugs 23 g Needle x 3 25 g Needle x 2 Coban x 1 Aspirin amp Syringe 50ml x 1 Anginine Penthrox Inhaler x 1 Gauze x4 Nasogastric Tubes x 3 Chest Needle Equipment Glucagon x 1 Intra Osseous Kit Nacl 10 ml Crepe 7 5 cm Hartmanns 1000 x 2 Metriset Giving Set x 2 x6 x2 Arm Splint x 1 Pump Set x 1 REMOVABLE IV ACCESS PANEL An IV Access Panel has been designed to place equipment on the panel in order of usage for gaining IV access Equipment Laid Out In Order Of Usage On The IV Access Panel Velcros Into Place The IV Access Panel is velcroed into place to allow the panel to be removable This wi
7. r the removable IV panel Layout Guide REFLECTIVE TAPE For maximum safety the ADK features full length reflective tape on sides and lid of the kit to enhance night time visibility during carrying and usage Reflexite On All Sides And Lid For Maximum Safety REMOVABLE BASES Removable bases have been placed on the two working surfaces of ADK to protect the main bag from wear and tear and to extend the life of the ADK These removable bases velcro into place lt is accepted that these bases will get worn and need replacing after a period of time Replacements can be ordered through Stores Officers need to ensure that both removable bases are always on the ADK for prehospital use and that replacements are ordered when required to maintain protection to the main bag ee dr a CD Removable Bases Velcros Into Place FABRIC All fabrics used in the ADK are designed to comply with the Australian Standards on Laundry Practice AS 4146 1994 The ADK is made of a new special formulated material known as Vironfrie which is a heavy duty easy to clean wipe down material This material while not as durable as the previous Cordura material used by the Ambulance Service Of N S W has been chosen due to it s significantly improved cleaning and OH amp S characteristics which allows the kit to be quickly washed and dried for reintroduction into Service and is less likely to absorb blood and other body contaminants To maintain
8. scitator components carefully Remove stiffening corflute from effected panels Blood Soak by placing effected panels in cold water An antibacterial solution Virkon should be added to the water Let effected part soak for 20 minutes Using Nifty gently sponge of residual stains Allow to ary thoroughly before use Vomit Soak by placing in hot water An antibacterial solution Virkon should be added to the water Using Nifty gently sponge of residual stains Allow to dry thoroughly before use In very heavy saturation the ADK can be dismantled soaked in cold water with an antibacterial solution Virkon for 2 hours rinsed and then emersed again and brought up to a temperature of 90 degrees Celsius and maintained for 10 minutes Using Nifty gently sponge of residual stains Dry thoroughly before reassembly and use Failure to comply with proper cleaning instructions may damage material and void warranty WARRANTY With 25 years of manufacturing experience and a commitment to using only the highest quality materials Neann s range of medical bags are guaranteed against faulty workmanship for the life of the bag This means if the bag fails due to a manufacturing fault it will be repaired or replaced at the manufacturers option This of course excludes fair wear and tear or misuse of the bag against manufacturers guidelines NEANN EMERGENCY CARE PRODUCTS By RAPP Australia Pty Ltd P O Box Lara Victoria 3212 Ph