Home

Leica TS02&06/09 plus Quick Guide

image

Contents

1. Leica TSO02 amp 06 09 plus Quick Guide Version 1 0 English 7 when it has to be right eca Geosystems TSO2 amp 06 09 plus Important Information about your Instrument 1 AW S Laser products Important Information about your Instrument Read and follow the User Manual on the accompanying CD before using the product or the accessories delivered with the product Keep for future reference e Measuring horizontal and vertical angles e Measuring distances e Visualising the aiming direction and vertical axis The instruments contain the following laser products Laser product Laser class EDM Electronic Distance Measurement module e measurements with reflectors Class 1 e measurements without reflectors Class 3R EGL Electronic Guide Light Exempt Group Laser plummet Class 2 optional laser product e The classification for the EDM and Laser plummet is in accordance with IEC 60825 1 2007 03 e The classification for the EGL is in accordance with IEC 62471 2006 07 A CAUTION From a Safety perspective class 3R laser products should be treated as potentially hazardous Precautions 1 Prevent direct eye exposure to the beam 2 Do not direct the beam at other people A CAUTION From a Safety perspective class 2 laser products are not inherently safe for the eyes Precautions 1 Avoid staring into the beam 2 Avoid pointing the beam at other people TSO2 amp 06
2. Icon AASA ae aa Description Displays the selected prism icon the EDM measurement activity icon or the active laser pointer icon For C amp T Tapping the icon opens the EDM Settings screen I ORG MG Displays the telescope position face or face II or the compensator status on off or out of range For C amp T Tapping the icon opens the Level amp Plummet screen maD me iD E c auto mO lt es Displays the keypad mode numeric or alphanumeric The icon is displayed when an editable field is highlighted For C amp T Tapping the icon switches the keypad mode Displays the communication port icon RS232 Bluetooth or USB or auto detect communication icon For C amp T Tapping the icon opens the Interface Settings screen Displays the status of the battery For C amp T Tapping the icon opens the Info screen AN b Displays that offset is active Horizontal angle is set to left side angle measurement Main Menu A b C a Gd T D r b c Programs d 5 f el e Transfer Setti f S_TSOX_004 Quick Survey program to begin meas uring immediately To select and start programs To manage jobs data codelists formats system memory and USB memory stick files To export and import data To change EDM configurations communication parameters and general instrument settings To access instrument related tools such as check and adjust personal startup settings P
3. P Long gt 4 0 km For long range distance measurements with prisms 5 mm 2 ppm NP Precise NP Tracking For distance measurements without prisms 2 mm 2 ppm gt 500 m 4 mm 2 ppm For continuous distance measurements without prisms 5mm 3 ppm TS02 amp 06 09 plus Operation 17 TSO2 amp 06 09 plus Operation Prism type 18 Round GPR Mini GMP Leica Const 0 0 mm Leica Const 17 5 mm MiniO GMP111 0 Leica Const 0 0 mm Leica Const 34 4 mm Jp Mini SMP222 360 GRZ4 Leica Const 23 1 mm Leica Const 30 0 mm 360 Mini GRZ101 Tape GZM None Leica Const 34 4 mm Leica Const 34 4 mm User 1 User 2 For any prism modes the user can define two of their own prisms Constants can be entered in mm in either Leica Const or Abs Const For example User prism constant 30 0 mm Leica Const 4 4 mm 34 4 30 4 4 Abs Const 30 0 mm Menu Tree Q Survey Programs Station Setup Survey Stakeout Tie Distance COGO Area amp DTM Volume Remote Height Traverse Reference Line Reference Arc Reference Plane Road 2D Road 3D Manage Job Fixpoints Meas Data Codes Formats Del Data USB Stick Transfer Export Import Settings Work Regional Data Screen EDM Interface Tools Ad
4. 09 plus Important Information about your Instrument 3 TSO2 amp 06 09 plus Important Information about your Instrument Locations of laser apertures 003975 001 LED beam red EGL LED beam yellow EGL Laser beam EDM Laser beam Laser plummet Exit for laser beam Laser plummet Conformity to national regula tions Products without Communi cation side cover Conformity to national regula tions Products with Communica tion side cover The product must not be disposed with household waste ance with the essential requirements and other relevant provisions of applicable European Directives The declaration of conformity may be consulted at http www leica geosystems com ce C Hereby Leica Geosystems AG declares that the instrument is in compli e FCC Part 15 applicable in US e Hereby Leica Geosystems AG declares that the instrument with Communication side cover is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC and other applicable European Directives The declaration of conformity may be consulted at http www leica geosys tems com ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can C 4 be placed on the market and be put into service without restrictions in any EEA Member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive
5. 1999 5 EC has to be approved prior to use and operation TSO2 amp 06 09 plus Important Information about your Instrument 5 TSO02 amp 06 09 plus Instrument Components 2 Instrument Components Instrument compo nents part 1 of 2 Compartment for USB memory stick and USB cable ports Bluetooth antenna Optical sight Detachable carrying handle with mounting screw Electronic Guide Light EGL Objective with integrated Electronic Distance Measurement EDM Exit for EDM laser beam Vertical drive On Off key Trigger key Horizontal drive Second keyboard Optional for TSO6 plus Optional for TSO6 plus TSO9 plus Instrument compo m nents part 2 of 2 TSOX_009b n O P q r S TS02 amp 06 09 plus Instrument Components Focusing telescope image Eyepiece focusing graticule Battery cover Serial interface RS232 Foot screw Display Keyboard model may vary depending on instrument Stylus TSO2 amp 06 09 plus Instrument Components Keyboard Color amp Touch keyboard I B 11 ABC DEF GHI 1 I 1 ye HJKL MNO POR I n 1 n 1 n i a u STU VWX YZ 1 TSOX_139 Standard keyboard TSOX_011 Alphanumeric keyboard Fixed keys Navigation key ENTER key ESC key Function keys F1 to F4 Alphanumeric keypad Stylus Keys TS02
6. IN code settings licence keys system information and firmware upload Despite an automatic defragmentation the memory gets fragmented after a while Please format the internal memory periodically to maintain the instrument perform ance TSO2 amp 06 09 plus Operation 15 TSO2 amp 06 09 plus Operation 16 Q Survey program Quick Survey E After switching on and setting up correctly the instrument is immediately ready for measuring 50 0000 g 66 6667 g Meas Dist Store Meas To start measurements and save the measured values Dist To start measurements and display the measured values Store To save the displayed values Code To find enter codes Available on page 4 4 or Code Or on any page press the FNC Favourites key and select Coding 4 Station To enter station data and set the station Set Hz To set the orientation to a user defined horizontal direction 3 Hz 4a Hz To set the horizontal angle reading to the left anticlockwise or to the right clockwise EDM Settings EDM mode P Preciset Fine measuring mode for highest precision measurements with prisms 1 5 mm 2 ppm P Precise amp Fast Quick measuring mode with prisms with higher measuring speed and high accuracy 2 mm 2 ppm for TSO2 3mm 2ppm P Tracking Tape For continuous distance measurements with prisms 3 mm 2 ppm For distance measurements using Retro reflective targets 5mm 2 ppm
7. amp 06 09 plus Instrument Components Key Description Page key Displays the next screen when several screens are avail able Ne x FNC Favourites key Quick access to measurement supporting O O functions a a2 User key 1 User key 2 Programmable with a function from the Favourites menu Navigation key Controls the focus bar within the screen and the entry bar within a field ENTER key Confirms an entry and continues to the next field Turns off the instrument when held for 3 seconds ESC key Quits a screen or edit mode without saving changes O Returns to next higher level GD Function keys F1 to F4 that are assigned the variable functions displayed at the bottom of the screen 5655660 Alphanumeric keys for entry of text and numerical values TSO02 amp 06 09 plus Instrument Components 10 Container contents a io j a Battery charger b Diagonal eyepiece c Data cable USB RS232 d Clip on bubble e Holder for height meter f Flat prism g Mini prism pole h Height meter i Protective cover Lens hood Cleaning cloth j Data cable USB mini USB k Mini prism I Adjustment tools m Batteries n Flat or mini prism adapter o Leica industrial grade USB memory stick p Battery q Tip for mini prism pole r Counterweight diagonal eyepiece s Instrument t Manuals Optional 3 Technical Data Environmental Temp
8. erature specifications Operating temperature C Storage temperature C 20 to 50 40 to 70 Protection against water dust and sand IP55 IEC 60529 Humidity Max 95 non condensing The effects of condensation are to be effectively counteracted by periodically drying out the instrument 4 Care and Transport Care and transport Carry the product in its original container or carry the tripod with its legs splayed across your shoulder to protect the product against shock and vibration e Periodically carry out test measurements and perform the field adjustments indi cated in the User Manual particularly after the product has been dropped stored for long periods or transported TSO2 amp 06 09 plus Technical Data 11 12 TSO2 amp 06 09 plus Operation Operation The battery must be charged before using it for the first time Turning on and off the instrument Screen a Hz o 50 0000 g i KD y z 66 6667 g d _ n 1 lt i ea a peas nT Meas Dist i a e Meas Dist Store a Title of screen a Status icons b Focus in screen Active field b Title of screen c Status icons c Focus in screen Active field d Fields d Fields e Softkeys e Softkeys CS Tapon an icon field or tab to run a function TSO2 amp 06 09 plus Operation 13 TSO2 amp 06 09 plus Operation Icons 14
9. just Startup Info Licence PIN Load FW TSO2 amp 06 09 plus Operation 19 Total Quality Management Our commitment to total customer satisfaction Leica Geosystems AG Heerbrugg Switzerland has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems ISO standard 9001 and Environmental ISO 9001 1SO 14001 Management Systems ISO standard 14001 Ask your local Leica Geosystems dealer for more information about our TQM program Leica Geosystems AG Heinrich Wild Strasse CH 9435 Heerbrugg Switzerland Phone 41 71 727 3131 www leica geosystems com when it has to be right C REV O O55 Cass O S S s 1 O wh N y a oi KN 7S O g M lt x va E w T A O w UO g S N re O N Geosystems

Download Pdf Manuals

image

Related Search

Related Contents

Ilford FP4 PLUS  Dicota 30027  TS65_32_Collect:Layout 1.qxd  Manual do Proprietário  Transition Networks CSEFE10XX-10X User's Manual  ECO-TRAP  CMX CRC 7210  

Copyright © All rights reserved.