USER`S MANUAL - Assured Automation

image

Contents

1. Press RESET twice dEC 22 will appear 2 3 Press and hold down RESET for 2 seconds program will appear 2 4 Press RESET to set the decimal point to 1st 2nd 3rd or no decimal place e g 11111 1 1 decimal place 2 5 Press and hold down RESET until program disappears to accept setting 2 6 Press RESET for five seconds to return the meter to the operating mode 3 23 RESETABLE ACCUM TOTAL unit 23 set units 3 1 Press and hold down RESET for 5 seconds until totL2 appears 3 2 Press RESET three times unit 23 will appear 3 3 Press and hold down RESET for 2 seconds program will appear 3 4 Press RESET to scroll through the settings ltr gal qrt to the desired units 3 5 Press and hold down RESET until program disappears to accept setting 3 6 Press RESET for five seconds to return the meter to the operating mode Contact us for the most recent product and technical information Visit our website for more details assuredautomation com 2 ASSURED AUTOMATION 4 24 RESETABLE ACCUM TOTAL dEC 24 set decimal point 4 1 Press and hold down RESET for 5 seconds until totL2 appears 4 2 Press RESET four times dEC 24 will appear 4 3 Press and hold down RESET for 2 seconds program will appear 4 4 Press RESET to set the decimal point to 1st 2nd 3rd or no decimal place e g 11111 1 1 decimal place 4 5 Press and hold down RESET until program disappears
2. mode 35 FLOW Cut 35 set minumum measurable flowrate This value is the maximum time sec to measure the number of pulses set in nuM 34 5 1 Press and hold down RESET for 5 seconds until totL2 appears 5 2 Press the DISP button once to reach rAtE 3 5 3 Press RESET five times Cut 35 will appear 5 4 Press and hold down RESET for 2 seconds program will appear and the digit will flash To change press RESET 5 5 Press DISP to go to the next digit To change press RESET Note Total number is 999 9 5 6 Press and hold down RESET until program disappears to accept setting 5 7 Press RESET for five seconds to return the meter to the operating mode Display 1 41 SLEEP MODE SLP 41 set sleep mode 1 1 Press and hold down RESET for 5 seconds until totL2 appears 1 800 899 0553 assuredautomation com 1 2 Press the DISP button twice to reach diSP 4 1 3 Press RESET SLP 41 will appear 1 4 Press and hold down RESET for 2 seconds program will appear 1 5 Press RESET to select sleep setting no sleep sleep 1 6 Press and hold down RESET until program disappears to accept setting 1 7 Press RESET for five seconds to return the meter to the operating mode 2 42 UNIT unit 42 set default display Note The display will reset to the default units after a time which is set in time 43 If no units are set the display will remain as selected 2 1 Pr
3. ASSURED Pe NN AUTOMATION 1 800 899 0553 assuredautomation com Lube Oil Flow Meter USER S MANUAL Installation amp Maintenance Assured Automation 19 Walnut Avenue Clark New Jersey 07066 Tel 732 381 2255 Fax 732 381 2383 ASSURED AUTOMATION 1 INTRODUCTION The LM Series flow meter has incorporated the oval rotor principal into its design This has proven to be a highly reliable and highly accurate method of measuring flow providing exceptional repeatability and high accuracy This meter is designed for inline use with engine oil amp ATF up to a maximum viscosity of SAE 140 diesel amp water glycol mixtures with a maximum water content of less than 50 2 INSTALLATION Do not over tighten connections Assured Automation recommends that if you are using your meter as an inline application you should install a filter before the inlet of the meter 3 OPERATION Display Button Each press of the DISP button will allow you to scroll through the meter options Resetable Batch Total Resetable Accumulative Total Non Resetable Accumulative Total Flowrate Reset Button The RESET button allows you to reset the Batch Total or the Resettable Acumulative Total to zero To reset either the Batch total or Resetable Acumulative total Press the DISP button to scroll to either the Batch or Resetable total When the required total is displayed Press reset to zero the totalizer Flowrate This d
4. an the meter cover plate and place it on the body Take care not to damage the o ring Install the eight screws and tighten in a diagonal pattern to 1 nm 0 73 ft lb Visual check that the cap has been pulled down evenly Test the meter by turning the rotors with a finger or by applying low air pressure no more than a good breath to the inlet port of the meter This will confirm the meter is operating correctly Parts Diagram Meter Body Rotors O ring Seal Meter Cover Plate Eight 8 philips head screws _ 4 1 800 899 0553 assuredautomation com 6 TROUBLE SHOOTING Problem No fluid passing through the meter 1 Cause Dirt particles jamming the rotors Remedy Remove rotors and remove any dirt or contamination Problem The meter is not registering fluid output 1 Cause Flat battery Remedy Replace battery Cause No signal from rotor the magnets Remedy Check magnets and replace rotors if required Cause Damaged computer reed switch unit Remedy Replace meter Problem Meter not accurate 1 Cause Flow rate outside recommended flow rate Remedy Adjust flow rate 2 Cause K factor incorrect Remedy Reset K factor to factory setting 112 00 pulses Contact us for the most recent product and technical information Visit our website for more details assuredautomation com 6
5. as soon as the battery indicator on the LCD is displayed Only use Alkaline batteries 1 Remove the plastic protector shroud see Fig 1 from the meter body 2 Remove the battery cover 3 Replace the two AAA Alkaline batteries Refer to the front of the meter for correct battery orientation 4 Replace the battery cover and re fit the plastic shroud Meter Disassembly Caution Ensure the fluid supply to the meter is disconnected and the line pressure is released before disassembly 1 Remove the eight philips head screws from the meter cover 2 Remove the meter cover and o ring 3 Remove both rotors Contact us for the most recent product and technical information Visit our website for more details assuredautomation com ASSURED AUTOMATION 4 Clean and inspect all parts Replace any suspect worn or damaged components Meter Reassembly Note Ensure the rotor with the magnets is assembled on the same side as the batteries The magnets in the rotor must face towards the electronic display 1 Fig 2 Replace both rotors so as they are at 90 to each other see Fig 2 Check the rotor rotation by turning either of the rotors If the rotors are not in mesh correctly or do not rotate freely remove one of the rotors and replace it correctly at 90 to the other rotor Recheck the operation of the rotors Lightly grease the o ring and place it on the meter body Cle
6. ess RESET digit will flash to change digit press RESET Press DISP to scroll to the next number Press RESET to change the value To change the decimal point press DISP until it is in the required position Press RESET to set the decimal point 7 5 Press and hold down RESET until program disappears to accept setting 7 6 Press RESET for five seconds to return the meter to the operating mode Flow Rate 1 31 UNITS unit 31 set units 1 1 Press and hold down RESET for 5 seconds until totL2 appears 1 2 Press the DISP button once to reach rAtE 3 1 3 Press RESET unit 31 will appear 1 4 Press and hold down RESET for 2 seconds program will appear 1 5 Press RESET to scroll through the settings ltr gal qrt to the desired units 1 6 Press and hold down RESET until program disappears to accept setting 1 7 Press RESET for five seconds to return the meter to the operating mode 32 DECIMAL POINT dEC 32 decimal point setting 2 1 Press and hold down RESET for 5 seconds until totL2 appears 2 2 Press the DISP button once to reach rAtE 3 2 3 Press RESET twice dEC 32 will appear 2 4 Press and hold down RESET for 2 seconds program will appear 2 5 Press RESET to set the decimal point to 1st 2nd 3rd or no decimal place e g 11111 1 1 decimal place 2 6 Press and hold down RESET until program disappears to accept setting 2 7 Press RESET
7. ess and hold down RESET for 5 seconds until totL2 appears 2 2 Press the DISP button twice to reach diSP 4 2 3 Press RESET twice unit 42 will appear 2 4 Press and hold down RESET for 2 seconds program will appear 2 5 Press RESET to select required display batch reset total total rate blank 2 6 Press and hold down RESET until program disappears to accept setting 2 7 Press RESET for five seconds to return the meter to the operating mode 3 43 TIME tiME 43 time to revert to default display 3 1 Press and hold down RESET for 5 seconds until totL2 appears 3 2 Press the DISP button twice to reach diSP 4 3 4 Press RESET three times tiME 43 will appear 3 5 Press and hold down RESET for 2 seconds program will appear 3 6 Press RESET to select default time 5 to 20 seconds 3 7 Press and hold down RESET until program disappears to accept setting 3 8 Press RESET for five seconds to return the meter to the operating mode Calibration Note Provides calibration adjustment up to 5 of reading You will need to calculate the percentage adjustment you require If the meter is reading over you will need to enter a minus figure If the meter is reading under you will need to enter a plus figure Contact us for the most recent product and technical information Visit our website for more details assuredautomation com 4 ASSURED AUTOMATION 1 Reset the ba
8. for five seconds to return the meter to the operating mode 33 TIME tiME 33 rate time base 3 1 Press and hold down RESET for 5 seconds until totL2 appears 3 2 Press the DISP button once to reach rAtE 3 Contact us for the most recent product and technical information Visit our website for more details assuredautomation com 3 ASSURED AUTOMATION 3 4 Press RESET three times tiME 33 will appear 3 5 Press and hold down RESET for 2 seconds program will appear 3 6 Press RESET to set time base seconds minutes hours 3 7 Press and hold down RESET until program disappears to accept setting 3 8 Press RESET for five seconds to return the meter to the operating mode 34 NUMBER OF PULSES nuM 34 number of pulses used to calculate flowrate Note When there is fluctuating flowrate present increasing the number will give a more accurate flowrate reading number range is O to 299 4 1 Press and hold down RESET for 5 seconds until totL2 appears 4 2 Press the DISP button once to reach rAtE 3 4 3 Press RESET four times nuM 34 will appear 4 4 Press and hold down RESET for 2 seconds program will appear and the digit will flash To change press RESET 4 5 Press DISP to go to the next digit To change press RESET 4 6 Press and hold down RESET until program disappears to accept setting 4 7 Press RESET for five seconds to return the meter to the operating
9. he screen will flash between SEr and the 6 figure serial number at 2 second intervals 1 7 Press RESET MAN plus manufacturer number 1 8 Press RESET the screen will flash between CONFIG and the configuration number at 2 second intervals 1 9 Press RESET for five seconds to return the meter to the operating mode 1 800 899 0553 assuredautomation com Diagnostics 1 71 DIAGNOSTICS dlA 7 diagnostic mode 1 1 Press and hold down RESET for 5 seconds until totL2 appears 1 2 Press the DISP button five times to reach dIA 7 1 3 Press and hold down RESET for 2 seconds Program will appear then all the segments should be displayed 1 4 Press the DISP button diSP to check that the display button is working properly 1 5 Press the RESET button RESEt to check that the reset button is working properly 1 6 Press and hold down RESET for 2 seconds program will disappear check the condition of the reed switch Note The display shows Hxx rYY when fluid flows through the meter YY is the sensitivity of the reed switch The condition of the reed switch can only be checked when there is liquid flowing through the meter The reed switch should be reading between 50 to 80 1 7 Press RESET for five seconds to return the meter to the operating mode 5 MAINTENANCE Battery Replacement All data will be saved when the batteries are removed Note Replace the batteries
10. isplay option shows the flowrate of the fluid passing through the meter Sleep Mode If NO flow goes through the meter for 60 seconds the display will go into sleep mode blank The display will automatically wake if the buttons are pressed or flow occurs Electronic Module Programming Details Note As the decimal point does not float we recommend that a maximum of 2 decimal places be used see below for details The electronic module has been set up as follows 1 Ensure the meter is awake before trying to enter the programming mode 2 If the meter goes into sleep mode during programming it will automatically return to operating mode 1 800 899 0553 assuredautomation com 3 To access the programs and settings hold down the RESET button for 5 seconds 4 To scroll through the setting options press the DISP button Totals 1 21 BATCH TOTAL unit 21 set units 1 1 Press and hold down RESET for 5 seconds until totL2 appears 1 2 Press RESET unit 21 will appear 1 3 Press and hold down RESET for 2 seconds program will appear 1 4 Press RESET to scroll through the settings Itr gal qrt to the desired units 1 5 Press and hold down RESET until program disappears to accept setting 1 6 Press RESET for five seconds to return the meter to the operating mode 2 22 BATCH TOTAL dEC 22 set decimal point 2 1 Press and hold down RESET for 5 seconds until totL2 appears 2 2
11. tch reading to zero 2 Dispence at least 5 liters using a constant flow rate into a graduated calibrated container 3 Take the reading from the meter 4 Calculate the error as follows error container volume meter volume container volume x 100 5 Enter the error into the meter as calculated if the value is negative enter a negative number 6 51 CALIBRATION CALI 51 adjust calibration 5 6 1 Press and hold down RESET for 5 seconds until totL2 appears 6 2 Press the DISP button three times to reach CALI 5 6 3 Press RESET CALI 51 will appear 6 4 Press and hold down RESET for 2 seconds program will appear 6 5 Press RESET to change number Press DISP to change the decimal point position or go to the next number Press the RESET button to set the negative value 6 6 Press and hold down RESET until program disappears to accept setting 6 7 Press RESET for five seconds to return the meter to the operating mode Configuration 1 61 CONFIGURATION CONF 6 configuration details 1 1 Press and hold down RESET for 5 seconds until totL2 appears 1 2 Press the DISP button four times to reach CONF 6 1 3 Press RESET MOD plus model number will appear 1 4 Press RESET REL plus hardware release number will appear 1 5 Press RESET the screen will flash between SOFT and the software release number at 2 second intervals 1 6 Press RESET t
12. to accept setting 4 6 Press RESET for five seconds to return the meter to the operating mode 5 25 NON RESET ACCUM TOTAL unit 25 set units 5 1 Press and hold down RESET for 5 seconds until totL2 appears 5 2 Press RESET five times unit 25 will appear 5 3 Press and hold down RESET for 2 seconds program will appear 5 4 Press RESET to scroll through the settings Itr gal qrt to the desired units 5 5 Press and hold down RESET until program disappears to accept setting 5 6 Press RESET for five seconds to return the meter to the operating mode 6 26 NON RESET ACCUM TOTAL dEC 26 set decimal point 6 1 Press and hold down RESET for 5 seconds until totL2 appears 6 2 Press RESET six times dEC 26 will appear 6 3 Press and hold down RESET for 2 seconds program will appear 6 4 Press RESET to set the decimal point to 1st 2nd 3rd or no decimal place e g 11111 1 1 decimal place 6 5 Press and hold down RESET until program disappears to accept setting 6 6 Press RESET for five seconds to return the meter to the operating mode 7 27 K FACTOR kFac 27 normal setting is 112 00 pulses 7 1 Press and hold down RESET for 5 seconds until totL2 appears 7 2 Press RESET seven times kFac 27 will appear 7 3 Press and hold down RESET for 2 seconds program will appear 1 800 899 0553 assuredautomation com 7 4 To change the Kk factor pr

Download Pdf Manuals

image

Related Search

Related Contents

White Rodgers 1F79 Thermostat User Manual  7220 Group USER`S MANUAL  Ronds-points : l`exception française  Backup & Restore  Dossier de presse - Les Cahiers pédagogiques  User Manual  ColorEdge CG275W Manuel d`utilisation  Grille d`analyse des publics et de leurs motifs d`éloignement Public  Samsung 941MP Korisničko uputstvo  Bedienungsanleitung Universal-Probenpumpe Katalognr  