1.  REC     on the top line  a value in the middle  and below it the letter    P    on the left and a number  from 1 to 99 on the same line to the right  The number indicates the position on the SD  card that will be used to store manually logged data     Now press the LOGGER A button  This will cause the beeper to sound and the term     LOGGER    to briefly appear at the upper right of the display  As in automatic datalogging  mode  in this mode the instrument is storing measurements and their time stamps on the  SD card     In manual datalogging mode  however  measurements are being stored continuously   with a sampling time of zero   and their locations on the card can be changed     8    5  To change the storage location of manually logged data  press the SET W button  once  this causes the    P    to disappear from the left side of the display and the value on  its line to begin flashing  Once the flashing begins  you can use the SET W and LOGGER  A buttons to change the flashing value to any number between 1 and 99  Once you have  chosen the storage location  press the REC ENTER button to save the setting  This causes  the value to stop flashing and the    P    to return     6  To end manual datalogging  press the REC ENTER button and hold it for at least three  seconds  This action causes the    REC    message to disappear from the top line of the  display     a TO B Lc    ae s  PA oe  _1  Piace Date Time  Value ni  TRANSFERRING 2 1 2009 12 11 09 55 56 2 37 UVA mWiem2  DA
2.  button for at least three  seconds  until the term    REC    disappears from the top line of the display  The display will  then revert to showing the current reading     AUTOMATIC VS  MANUAL DATALOGGING    The UV254SD can automatically log data using any of 11 sampling times from 1 second to  1 hour  To view the sampling time for which the instrument was set up  press the LOGGER  A button once  To change the sampling time  press the SET W button to enter setup mode  and perform Step 9 of the setup procedure     1  To start automatic datalogging  press the REC ENTER button once  The top line of the  display will then show the term    REC     Pressing the LOGGER button at this point will  make REC flash and add the flashing term    LOGGER    at the top right of the display  This  indicates that the instrument is currently storing measured values and their time stamps  in memory     2  To pause automatic datalogging  press the LOGGER A button once  this action makes  the flashing term LOGGER disappear from the top right of the display and changes the  term    REC    from flashing to constant  Pressing the LOGGER A button again resumes  automatic datalogging     3  To end automatic datalogging  press the REC ENTER button and hold it for at least  two seconds  This action causes the    REC    message to disappear     4  To log data manually  set the sampling time to zero using Step 9 of the setup  procedure  Then press the REC ENTER button once  The display will show the term   
3.  for at least five  seconds  until    SEt dAtE    appears on the display  Quickly  within three seconds  press  the REC ENTER button  The word    dAtE    will appear in the center of the display  along  with the flashing value    00 00 00    at the lower left  above    yy mm dd         If you press buttons too slowly in setup mode  the screen will revert to the normal display   To return to the setup sequence  press and hold the SET W button again  To move ahead to  the next field in the sequence or to the next parameter  press the FUNC  HOLD NEXT button   callout 1 3       Set the current year by pressing the SET W or LOGGER A button repeatedly until the  correct value appears above    yy     Quickly  within three seconds   press the REC ENTER  button to store the setting  The next screen that appears will have the value above    mm     flashing  Use the SET W or LOGGER A button to navigate to the current month and press  the REC ENTER button to store the setting  When the next screen flashes the value above     dd     again use the SET W or LOGGER A button to navigate to the current day and press  the REC ENTER button to store the setting     Once you have set the date  the display will prompt you to set the hour  minute and second  of the current time  Again use the SET W or LOGGER A buttons to navigate to the correct  values  and the REC ENTER button to store the settings     4  Choose a period or a comma to represent the decimal division between integers and  fractions  
4.  type Liquid crystal with green backlight  Display size 2 05 x 1 5 in   52 x 38mm    UV light types measured UVA  UVC   Measurement range 240nm to 390nm    Measurement accuracy  Full scale autoranges     4  of full scale reading   2 digits  2 mW cm  and 20 mW  cm        Stored readings  Datalogging sampling times  SD card capacity    Maximum  minimum  1 second to 1 hour  automatic mode   1 GB to 16 GB       Settable parameters    Date  time  auto power off  beep sound  temperature unit     F or   C   sampling time  thermocouple type  K or J    decimal point or comma       Operating temperature  Operating relative humidity    32   to 122  F  0   to 50  C   0 to 85        Power source    6 Alkaline    AA    batteries or optional 9 VDC AC adapter       Power consumption    Dimensions of meter  Weight of meter    6 5 mADC  normal operation  with backlight off and SD  card not saving data  30 mADC with backlight on     6 97 x 2 68 x 1 77 in   177 x 68 x 45mm   12 38 0z   351g        Dimensions of UVA probe head  Dimensions of UVA probe handle    1 77 in   diagonal  x 1 26 in   L   45 x 32mm   0 94 in   diagonal  x 4 92 in   L   24 x 125mm           Weight of UVA probe 3 53 oz   100g   Dimensions of UVC probe 1 50  diagonal  x 0 98 in   L   88 x 25mm   Weight of UVC probe 3 63 02   103g     MAINTENANCE  amp  TROUBLESHOOTING TIPS    Keep the UV light probes clean and their sensors under their protective covers when not in use     When the icon cx  appears in the left corner of the d
5. GENERAL    UV254SD  USER   S MANUAL       UVA AND UVC LIGHT METER  WITH DATALOGGING SD CARD    Please read this manual carefully and thoroughly before using this product     TABLE OF CONTENTS    INTFOCUENON fence Ge oe ee ee oe ee ees 3  Key FO AUS ic ciuiiose oes aha a ete aed ee ee ee ee 3  Operating Instructions                0000000  4 9  What s in the Case          0ccceee eens 4  SOUP iui au aaa aa ates asus 5 6  Normal Operation             000ecee enna 7  Holding and Storing Measurements           8  Automatic vs  Manual Datalogging         8 9  Transferring Data from the SD Card  toa Computer          ccc cece eee eee 9  Specifications 222k ee eee es 10  Maintenance  amp  Troubleshooting Tips         10 11  Replacement Parts  amp  Optional Accessories        11  Warranty Information              0000eeeeeees 11    Return for Repair Policy              000eeeeee 11    INTRODUCTION    Thank you for purchasing General Tools  amp  Instruments    UV254SD UVA and UVC Light Meter  with Datalogging SD Card  Please read this user   s manual carefully and thoroughly before  using the instrument     Many industrial and commercial applications require or can benefit from measurement of  the intensity of UVA and or UVC light  Among them are welding  to minimize exposure to     blue light    radiation   UV sterilization of food  photochemical matching  erasure of  electrically programmable read only memory  EPROM  chips  production of graphic arts  products  exposure of photoresi
6. T W or LOGGER A  button until the unit you prefer     F    for Fahrenheit     C    for Celsius     is displayed  Then  press the REC ENTER button to store the selection as the default     9  Set the datalogging sampling time  Once the thermocouple type has been selected  and stored  the display will show a value above the letters    SP t     Press the SET W or  LOGGER A button to decrease or increase the value until the desired sampling time  appears above    SP t     The options are 0  1  2  5  10  30  60  120  300  600  1800 and  3600 seconds  0 seconds to 1 hour      10  Format the SD card  Once the sampling time has been set and stored  the term    Sd F     will appear in the lower half of the display  Press the REC ENTER button     Pressing the REC ENTER button causes the word    no    or    yES    to appear over the term     Sd F     Press the W button to make a selection  Choose    yES    whenever a new SD card is  being used  or when a used card is being repurposed  from use with another SD card  instrument or a camera  for example  and all data on it is to be erased  Choose    no    to  preserve any data on a card previously used with this instrument     If you choose    yES     after you press the REC ENTER button the instrument will prompt you  to confirm that decision by displaying the term    Ent    below    yES    and sounding three  beeps  To confirm that you want to begin the erasure formatting procedure  press the  REC ENTER button     Ent    will then flash 
7. TA FROM IHE  EE 3 2000 12 11 09 3600  248 UVA mWieuz  4    56  mW   SD CARD TO A s   4 2009 12 11 09 56 02 3 29 UVA mW em2  COMPUTER 6  5 2009 12 11 09 56 04 3 74 UVA mW cm2    Z  6 2009 12 11 09 56 06 3 89 UVA mW em2  After automatic or g  7 2009 12 11 09 56 08 3 14 UVA mW cm2  j      8 2009 12 11 09 56 10 2 23 UVA mW cm2  MAPE ise aloe o 9 2009 12 11 09 56 12 0 953 UVA mW cm2   10    56  m  measurements  remove ii 10 2009 12 11 09 56 14 1 011 UVA mW cm2  the SD card from the 12   11 2009 12 11 09 56 16 0 981 UVA mW cm2  UV254SD and plug it 33 12 2009 12 11 09 56 18 0 673 UVA mW cm2    Ta 13 2009 12 11 09 56 20 0 892 UVA mW cm2  into your computer 15  14 2009 12 11 09 56 22 2 16 UVA mW cm2  either directly  if it has 16 15 2009 12 11 09 56 24 3 55 UVA mW cm2  17   16 2009 12 11 09 56 26 3 97 UVA mW cm2  an SD card port  or 18 17 2009 12 11 09 56 28 3 94 UVA mW cm2  through an SD card 19   18 2009 12 11 09 56 30 3 94 UVA mW cm2  reader  20   19 2009 12 11 09 56 32 3 94 UVA mW cm2  21 20 2009 12 11 09 56 34 3 95 UVA mW cm2    Because the files  containing the time   stamped data logs  have the extension  Xls   they open in Microsofts      Excel application   Figures 2 and 3 show  two kinds of Excel  presentations  a  data only screen and   a graphics only screen     Fig  2  Typical Excel data only screen    mW cm2                            Fig  3  Typical Excel graphics only screen    SPECIFICATIONS    Embedded microcontroller    Custom one chip LSI device             Display
8. W button  Doing so causes both values to appear briefly  at the lower left of the display     2  To measure the intensity of UVA light  seat the UVA probe  with its cap on  in the  socket at the top of the UV254SD  callout 1 7  and use the FUNC HOLD NEXT button to  select UVA measurement mode  If the display shows a value other than zero  press the  LOGGER button  which has the word    Zero    stenciled above it  and hold it for at least  three seconds until you hear a beep  Then remove the cap from the probe     Holding the probe by its handle  point the sensor at its end directly at the light source  The  display will read out the intensity of the source   s UVA light component in units of mW cm      3  To measure the intensity of UVC light  seat the UVC probe  with its cap on  in the  socket at the top of the UV254SD and use the FUNC HOLD NEXT button to select UVC  measurement mode  If the display shows a value other than zero  press the LOGGER  amp   button  which has the word    Zero    stenciled above it  and hold it for at least three  seconds until you hear a beep  Then remove the cap from the probe     Holding the probe by its handle  point the sensor at its end directly at the light source  The  display will read out the intensity of the source   s UVC light component in units of mW cm      4  To measure temperature  first make sure neither the UVA nor the UVC probe is plugged  into the instrument  Then use the FUNC HOLD NEXT button to select temperature  measuremen
9. com  www generaltools com  UV254SD User   s Manual  Specifications subject to change without notice      2010 GENERAL TOOLS  amp  INSTRUMENTS  NOTICE   WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS   MAN UV254SD 12 03 10    
10. empted  repair by non authorized personnel or misuse  alterations  normal wear and tear  or  accidental damage  The defective unit must be returned to General Tools  amp  Instruments or  to a General authorized service center  freight prepaid and insured     Acceptance of the exclusive repair and replacement remedies described herein is a  condition of the contract for purchase of this product  In no event shall General be liable for  any incidental  special  consequential or punitive damages  or for any cost  attorneys    fees   expenses  or losses alleged to be a consequence of any damage due to failure of  or defect  in any product including  but not limited to  any claims for loss of profits     RETURN FOR REPAIR POLICY    Every effort has been made to provide you with a reliable product of superior quality   However  in the event your instrument requires repair  please contact our Customer Service  to obtain an RGA  Return Goods Authorization  number before forwarding the unit via  prepaid freight to the attention of our Service Center at this address     General Tools  amp  Instruments  80 White Street   New York  NY 10013  212 431 6100    Remember to include a copy of your proof of purchase  your return address  and your  phone number and or e mail address     Specialty Tools  amp  Instruments       GENERAL TOOLS  amp  INSTRUMENTS  80 White Street   New York  NY 10013 3567   PHONE  212  431 6100  FAX  212  431 6499  TOLL FREE  800  697 8665  e mail  sales generaltools 
11. for example  American style 20 88 vs  European style 20 88   Press the SET  Y button to make    bASIC     American style  or    Euro    appear in the upper display  as  desired  Press the REC ENTER button to store the selection     5  Enable or disable auto power off  Once the format of decimal divisions has been set  and stored  the display will show the word    yES    over the term    PoFF     Press the SET  Y button until the desired automatic power off management scheme     yES    for enable      no    for disable  is displayed  Press the REC ENTER button to store the selection  If  enabled  the power off function shuts off the UV254SD after a period of inactivity of ten  minutes     6  Enable or disable the beeper  Once the desired power management function has been  set and stored  the display will show the word    yES    over the word    bEEP     Press the  SET V button until the desired setting     yES    or    no     is displayed  and then press the  REC ENTER button to store the selection     7  Select the thermocouple type  Once the beeper has been enabled or disabled  the  display will show the word    Set    over the word    type     Press the SET W button until  your optional thermocouple   s type  K or J  appears on the right side of the display  Then  press the REC ENTER button to store the selection     8  Select the temperature unit  Once the thermocouple type has been set and stored  the  lower part of the display will show the term    t CF     Press the SE
12. isplay  it   s time to replace the six     AA    batteries that power the instrument  although measurements will remain valid for  several hours after the low battery indicator first appears   Replacing the batteries requires  removing the two screws that hold the battery compartment cover in place  as explained in  Step 1of the setup procedure on page 5  After inserting fresh batteries in the correct  orientation  tighten the screws to secure the cover     10    If the meter    freezes     like a computer  and buttons become unresponsive  try resetting the  instrument by pushing the RESET button on its right side  callout 1 11 of Fig  1  with the  end of a paper clip     Remove the batteries when storing this product for an extended period of time   Do not drop or disassemble the instrument or immerse it in water     REPLACEMENT PARTS  amp  OPTIONAL ACCESSORIES  e Type K and Type J thermocouples  e 9 VDC adapter for 110VAC power supply  e Spare UVA probe  e Spare UVC probe    WARRANTY INFORMATION    General Tools  amp  Instruments     General   s  UV254SD UVA and UVC Light Meter with  Datalogging SD Card is warranted to the original purchaser to be free from defects in  material and workmanship  Subject to certain restrictions  General will repair or replace this  instrument if  after examination  the company determines it to be defective in material or  workmanship for a period of one year     This warranty does not apply to damages that General determines to be from an att
13. r housing   1 19 UVC sensor   1 20 UVA probe handle   1 21 UVA sensor   1 22 UVA probe plug   1 23 UVA sensor cap    SETUP    1  Choose the power source  Before using the UV254SD  be sure it is powered by fresh  batteries or an optional 9VDC AC adapter plugged into the bottom jack on its right side   callout 1 12      To remove the battery compartment cover  remove the two screws holding it in place   callout 1 14   Then install six    AA    batteries in the correct orientation  using the polarity  marks on the inside of the compartment as a guide  Replace the cover by replacing the  two screws     2  Install an SD card  To prepare for setup  also install the supplied 2 GB SD memory card  or another card with a capacity from 1 GB to 16 GB in the socket on the bottom of the  UV254SD  callout 1 9   When installing the card  make sure its gold contacts are facing  front and push the card into the socket until you hear a click  To remove the card  push it  in until you hear a click and the card pops out     Now power on the instrument by pressing the POWER ESC button  callout 1 2  to generate  a short beep   To power off the UV254SD  press the POWER ESC button and hold it until the  instrument responds with a long beep      When the meter powers on  a series of transient startup screens will briefly appear  Once  the display has stabilized  perform the following eight setup steps in the order presented     3  Set the date and time  Press the SET W button  callout 1 5  and hold it
14. several times and the instrument will sound  another three beeps to confirm that the SD card has been erased and formatted     Once the SD card has been formatted  or not   the display will either return to the first of the  eight steps in the setup sequence   setting the current date and time   or show the term     ESC     If    ESC    appears  press the POWER ESC button to exit the setup procedure and  enter normal operating mode     NORMAL OPERATION  The UV254SD can measure and store three different kinds of values     e The intensity  in mW cm   of UVA light  e The intensity  in mW cm2  of UVC light  e Temperature  in   F or   C   as sensed by a Type K or Type J thermocouple    Pressing and holding the FUNC  HOLD NEXT button will bring up  in order  three blank  five digit displays above the terms    A     for UVA light      C     for UVC light  and    tP     for  temperature   Each display also automatically shows the correct unit for the parameter     1  To select the measurement mode  release the FUNC  HOLD NEXT button when the  desired parameter appears  This becomes the meter   s default measurement mode until  you change it     Whenever the UV254SD is in measurement mode  you can turn off the backlight  which is  on by default  by briefly pressing  but not holding  the POWER ESC button  To reactivate the  backlight  briefly press the button again     Whenever the meter is in measurement mode  you also can check the current date and  time by briefly pressing the SET 
15. sts  and curing of inks  adhesives and coatings     The UV254SD has the performance and features needed to satisfy the most demanding  aspects of these applications  For example  it combines the capabilities of UVA  black light  in the long wave 365 nm band  and UVC  short waves in the 254 nm band  measurement  in one instrument  The meter also can measure surface temperature  if mated with a Type K  or Type J thermocouple  A UVA probe and a UVC probe are supplied with the instrument     Because it is microprocessor based  the UV254SD can make full use of the portability   reliability and large storage capacities that SD memory cards offer  Measurements of light  intensity or temperature can be made automatically at any of 11 sampling rates between  one second and one hour  After time stamping and storing the measurements on an SD  card plugged into the instrument  a process called datalogging   the user can remove the  card and transfer the measurements to a laptop or desktop computer either directly or via a  USB card reader     The UV254SD has a backlit 2 1 2 in  diagonal display and is powered by six    AA    Alkaline  batteries or an optional 9 VDC AC adapter     KEY FEATURES  e Includes UVA and UVC probes    e Measures light intensity within two automatically switched full scale ranges   2 mW cm  and 20 mW cm     e Displays maximum and minimum readings    e Performs real time automatic datalogging at sampling time settable from  1 second to 1 hour    e Also supports man
16. t mode     Obtain a Type K or Type J thermocouple and seat it in the socket  callout 1 8  on the top of  the UV254SD  The display will read out the sensed temperature in degrees F or C    depending on the setting chosen during setup   along with the type of thermocouple it is  configured for     To change the unit of measurement  press the SET W button to enter setup mode and  perform Step 8 of the setup procedure  To configure the meter for use with a Type J  thermocouple  Type K is the default   press the SET W button to enter setup mode and  perform Step 7 of the setup procedure     HOLDING AND STORING MEASUREMENTS    1  To hold a measured value of light intensity or temperature  press the FUNC  HOLD NEXT  button during the measurement  Doing so will cause the word    HOLD    to appear at the  top of the display  Pressing the FUNC  HOLD NEXT button again releases the hold     2  To record and recall readings  press the REC ENTER button while making  measurements  This will make the term    REC    appear at the top of the display  Pressing  the REC ENTER button again  briefly  will make the term    MAX    appear to the right of     REC    and switch the display to the maximum value stored in memory during the last  recording session  Pressing the REC ENTER button again  briefly  will make the term     MIN    appear to the right of    REC    and switch the display to the minimum value stored  during the last session     3  To exit recording mode  press and hold the REC ENTER
17. ual logging and changing of card storage location  e Comes with 2 GB SD memory card  but works with cards up to 16 GB  e Big  2 5 in  diagonal  front panel green backlit LCD is easy to read   e Auto power off function   e Powered by six    AA    batteries or 9V AC DC adapter    OPERATING INSTRUCTIONS    WHAT   S IN THE CASE    The UV254SD comes fully assembled in a carrying case along with a UVA probe  a UVC  probe  a 2 GB SD memory card and this user   s manual     Figure 1 shows all of the controls and indicators on the front  back  top  bottom and right  side of the UV254SD  It also shows the main components of the supplied UVA and UVC  probes  Familiarize yourself with their positions and functions before moving on to the setup                                        procedure   TOP  rte OF     18    lt  N  mO    FRONT  4 2  1 5 4 17     U  BOTTOM RIGHT BACK UVC  4 9 SIDE PROBE UVA  PROBE    Fig  1  The controls and indicators and other physical features of the UV254SD and its    two supplied probes  1 1 Liquid crystal display  1 2 POWER ESC button  1 3 FUNC  HOLD NEXT button  1 4 REC ENTER button  1 5 SET W button  1 6 LOGGER A button  1 7 Socket for UVA and UVC probes    1 8 Socket for Type K or Type J  thermocouple    1 9 SD card socket  1 10 RS232 output jack  1 11 RESET button    4    1 12 Socket for 9VDC AC adapter  1 13 Battery compartment cover  1 14 Battery compartment cover screws  1 15 Kickstand   1 16 Tripod attachment nut   1 17 UVC probe plug   1 18 UVC senso
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
referência do produto recolha de lixo separado  G4 Snowmobile user guide  User`s Manual 9410500, Rev A, Protector Premier  SensAlarm Plus Remote Kit manual  MANIFIESTO DE CARGA FERROVIARIO  Customer Ser Customer Service 1111 Brookpark Rd. Cleveland OH  POWERbreathe K-Series Model Features Table  Lighting Control Console User Manual    Copyright © All rights reserved. 