1. etc are reported to main controller or not Available configuration parameters data type is 1 Byte DEC e default value 1 e 0 reporting to controller is disabled e 1 reporting to controller is enabled Parameter no 85 Power consumption max delay time This parameter defines the max time before motor power consumption is read after one of the relays is switched ON If there is no power consumption during this max time motor not connected damaged or requires higher time to start motor in end position the relay will switch OFF Available configuration parameters data type is 1 Byte DEC e default value 0 time is set automatically e 3 50 0 3seconds 5seconds 100ms resolution Parameter no 90 Relay delay time This parameter defines the time delay between output relay switching time between switching up down and vice versa Available configuration parameters data type is 1 Byte DEC e default value 5 500ms e 1 30 0 1seconds 3seconds 100ms resolution Technical Specifications 110 230 VAC 10 50 60Hz 24 30VDC output resistive load output resistive load Output circuit power of AC output resistive load Output circuit power of DC output resistive load accuracy P gt 200W 3 Digital temperature 50 125 C sensor range Sensor must be ordered separately Distance up to 30 m indoors depending on building materials Dimensions WxHxD
2. package 79x52x22 In case of load other than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Max current for cos o 0 4 is 2A at 250VAC 3A at 24VDC Note Do not connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Z Wave Device Class BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL Z Wave Supported Command Classes COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_ SWITCH_BINARY COMMAND_CLASS_METER_V3 COMMAND_CLASS_SENSOR_MULTILEVEL_V3 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ MANUFACTURER_ SPECIFIC COMMAND_CLASS_ VERSION COMMAND_CLASS_ MARK COMMAND_CLASS _BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Endpoint1 COMMAND_CLASS _BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_ SWITCH_BINARY COMMAND_CLASS_METER_V3 COMMAND_CLASS_SENSOR_MULTILEVEL_V3 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ MANUFACTURER_ SPECIFIC COMMAND_CLASS_ VERSION COMMAND_CLASS_MARK COMMAND_CLASS_SWITCH_MULTILEVEL_V3 This product can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All constantly powered nodes
3. in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network Important disclaimer Z wave wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its function Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without notice NOTE User manual is valid for Shutter module with SW version S6 and above SW version is part of P N Example P N ZMNHCAX H1S6P1 K CE Qubino Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Date 22 4 2015 Document Qubino_ Flush shutter user manual_V9 0_eng
4. mode on main controller e press service button S for more than 6 second or e press push button I1 five times within 3s 5 times change switch state within 3 seconds in the first 60 seconds after the module is connected to the power supply By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but configuration parameters are not set to default values Removing Associations Association enables Flush shutter module to transfer commands inside Z wave network directly without main controller to other Z Wave modules Associated Groups Group 1 basic on off triggered at change of the input 11 state and reflecting its state up to 16 nodes Group 2 basic on off triggered at change of the input 12 state and reflecting its state up to 16 nodes Group 3 multilevel triggered at changes of value of the Flush shutter position up to 16 nodes Group 4 multilevel triggered at changes of value of slats tilting position up to 16 nodes Group 5 default reporting group reserved for the main controller Automatic calibration Automatic calibration is a process during which the Flush shutter learns the position of the limit switches Shutter positioning calibration par 71 set to 0 There are two procedures of calibration e Calibration through main controller UI 1 Include the module into
5. position To change shutter lower position below already set manual recalibration parameter 74 must be set to 0 and repeat the procedure described above In case shutter has limit switches but anyhow you would like to limit opening closing position by time you can still do it In case you put time that is longer that opening closing real time limited by limit switches shutter will stop at limit switch but the module relay will switch off after define time not by shutter limit switch Take in consideration that in this condition the positioning with slider through UI will not show correct shutter position Parameter no 76 Motor operation detection Power threshold to be interpreted when motor reach the limit switch Available configuration parameters data type is 1 Byte DEC e default value 10 10W e Available settings O 127 0 127 W Note The value 0 means reaching a limit switch will not be detected Parameter no 78 Forced Shutter calibration By modifying the parameters setting from 0 to 1a Shutter enters the calibration mode Available configuration parameters data type is 1 Byte DEC e default value 0 e 1 Start calibration process after shutter performs the calibration process completing full cycle up down and up set the parameter 78 Forced Shutter calibration value back to 0 Parameter no 80 Reporting to controller This parameter defines if reports regarding power level multilevel
6. the Z wave network according to module inclusion instructions 2 Set the parameter 78 Forced Flush shutter calibration value to 1 3 Flush shutter performs the calibration process completing full cycle up down and up again 4 Set the parameter 78 Forced Flush shutter calibration value to 0 e Calibration through the switch keys I1 12 1 Include the module into the Z Wave network according to module inclusion instructions 2 Quick press the switch key connected to l1 input and wait until the shutter reach upper limit switch 3 Quick press the switch key connected to 12 input and wait until the shutter reach lower limit switch 4 Quick press the switch key connected to 11 input and wait until the shutter reach upper limit switch Slates tilting position calibration par 71 setto 1 When enabling venetian blind mode beside position calibration also slats tilting calibration must be done After that blind position and angle of slates can be set By default full turn for slates is set to 1 5s This value can be changed according to slates types and time by set value in parameter 72 1 Include and calibrate module according to section Shutter positioning calibration 2 Set parameter 71 to 1 Venetian blinds 3 Reconfigure node using main controller 4 After module reconfiguration beside main shutter widget another widget for slates control will appear on UI 5 Repeat Shutter positioning
7. Qubino The INNOVATIVE and SMALLEST Flush shutter ORDERING CODE Z WAVE FREQUENCY ZMNHCA2 868 4 MHz ZMNHCA3 921 4 MHz ZMNHCA4 908 4 MHz ZMNHCAS5 869 0 MHz ZMNHCA6 916 0 MHz Flush Shutter module is used to control the motor of blinds rollers shades garage doors gates venetian blinds including slates tilting positioning etc The module can be controlled either through a Z Wave network or through the wall switch Precise positioning is supported for motors equipped with mechanical or electronic end switches The module is designed to be mounted inside a flush mounting box hidden behind a traditional wall switch Module measures power consumption of motor and support connection of digital temperature sensor It is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches Installation e Before the installation disconnect power supply e Connect the module according to electrical diagram e Locate the antenna far from metal elements as far as possible e Do not shorten the antenna Danger of electrocution e Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician e Even when the module is turned off voltage may be present on its terminals Any works on configuration changes related to connection mode or load must be
8. always performed by disconnected power supply disable the fuse Package contents e Flush shutter Electrical diagram 230VAC L T ees ETE Notes for the diagram N Neutral lead L Live lead Q1 Output for motor UP open Q2 Output for motor DOWN close 12 Input for switch push button DOWN close l1 Input for switch push button UP open TS Terminal for digital temperature sensor only for Flush shutter module compatible digital temperature sensor which must be ordered separately S Service button used to add or remove module from the Z Wave network Durability of the device depends on applied load For resistive load light bulbs etc and 4A current consumption of each individual electrical device the durability exceeds 70 000 switches of each individual electrical device Module Inclusion Adding to Z wave network e Connect module to power supply with temperature sensor connected if purchased e bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e auto inclusion 80 minutes after connected to power supply or e press service button S for more than 2 second or e press push button I1 three times within 3s 3 times change switch state within 3 seconds Module Exclusion Reset from Z Wave network e Connect module to power supply e bring module within maximum 1 meter 3 feet of the main controller e enable add remove
9. calibration 6 By default full turn movement is set to 1 5s If this time is too long after slates full cycle shutter starts moving up or down decrease this time defined with parameter 72 Manual operation for shutter par 71 set to 0 Module allows connecting of push buttons mono stable or switches bi stable to 11 and 12 terminals Clicking up button lt 2s connected to l1 initiates up movement Clicking down button lt 2s connected to 12 initiates down movement If the shutter is moving each click of any button will stop the movement Keep pressed button gt 2s connected to l1 initiates up movement until the button is released Keep pressed button gt 2s connected to 12 initiates down movement until the button is released Manual operation for venetian blinds par 71 set to 1 Slates on start position Clicking up button for time lt full turn slate time par 72 connected to 11 initiates turning slates into stop direction until the button is released Clicking down button for time lt full turn slate time par 72 connected to 12 shutter initiates down movement If the shutter is moving each click of any button will stop the movement Slates on end position Clicking up button for time lt full turn slate time par 72 connected to 11 shutter initiates up movement If the shutter is moving each click of any button will stop the movement Clicking down button for time lt ful
10. h this will result that after full slats turn shutter will start move up or down for time remaining Parameter no 73 Slats position This parameter defines slats position after up down movement through UI or push buttons Configuration parameters data type is 1 Byte DEC e default value 2 e 0 e 1 0 Slats return to previously set position only in case of UI control 1 Slats return to previously set position in case of UI control push button operation or when the limit switch is reached 2 Slats return to previously set position in case of UI control push button when the limit switch is reached or after receiving a STOP control frame Switch Multilevel Stop Level Change from Ul Parameter no 74 Motor moving up down time This parameter defines shutter motor moving time for complete opening or complete closing Available configuration parameters data type is 2 Byte DEC e default value 0 e 0 moving time disabled working with limit switches e 1 32767 0 1seconds 3276 7seconds After that time motor is stopped relay goes to off state Set parameter 74 to 0 and move the shutter using up down push buttons or main controller UI to desired lower position On this shutter position set parameter 74 to time for complete opening or complete closing At this point shutter can be moved up open for set time but can t be moved down because this position is already set as lower shutter
11. l turn slate time par 72 connected to 12 initiates turning slates into start direction until the button is released Keep pressed button for time gt full turn slate time par 72 connected to l1 initiates full turn slate and up movement until the button is released Keep pressed button for time gt full turn slate time par 72 connected to 12 initiates full turn movement and down movement until the button is released Configuration parameters Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available configuration parameters data type is 2 Byte DEC e default value 255 e 255 ALL ON active ALL OFF active e 0 ALLON is not active ALL OFF is not active e 1 ALLON is not active ALL OFF active e 2 ALLON is not active ALL OFF is not active Module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 40 Power reporting in Watts on power change for Q1 or Q2 Set value means percentage set value from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC e default value 1 e 0 Reporting Disabled e 1 100 1 100 Reporting enabled Power report is send push only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed inde
12. pendent of percentage set Parameter no 42 Power reporting in Watts by time interval for Q1 or Q2 Set value means time interval 0 32767 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC e default value 300 power report in Watts is send each 300s e 0 Reporting Disabled e 1 32767 1 second 32767 seconds Reporting enabled power report is send with time interval set by entered value Parameter no 45 Self measurement Module may include power and energy used by module itself in reports sent to the main controller Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 Self measurement disabled e 1 Self measurement enable Parameter no 71 Operating modes This parameter defines selection between two available operating modes Configuration parameters data type is 1 Byte DEC e default value 0 e 0 Shutter mode e 1 Venetian mode up down and slate rotation NOTE After setting parameter module needs to be reconfigured Please check detailed description in this manual Parameter no 72 Slats tilting full turn time This parameter defines the time necessary for slats to make full turn 180 degrees Configuration parameters data type is 2 Byte DEC e default value 150 1 5 seconds e 0 Tilting time disabled e 1 32767 0 01seconds 327 67 seconds NOTE If time set is too hig
Download Pdf Manuals
Related Search
Related Contents
Panel de descarga manual Serie 755 30.41-SPAL Bosch TKN68E75UC User's Manual Cables Direct RB-528 power cable Microfinance et financement de l`agriculture familiale 前 言 Guía para el usuario 関連PDF1 KP-06 プリンター 取扱説明書 製品安全データシート - 株式会社 ペルセウスプロテオミクス BioPlus 2B for Canada whey 6_03 Copyright © All rights reserved.