2711E-UM003B-EN-P, PanelView e Transfer Utility User Manual
Contents
1. 1770 KFC PanelView 1400e with 1784 KTCX or 1784 KTCS card 25041 Publication 2711E UM003B EN P 2 10 Working with the PanelView e Transfer Utility 32 Figure 2 6 ControlNet Network Download with 1784 KTC or KTCX card Development Computer with KTCX Card PanelView 1400e with 1784 KTCX15 or 1784 KTCS card Publication 2711E UM003B EN P Working with the PanelView e Transfer Utility 32 2 11 Figure 2 7 ControlNet Network Download with Logix55xx Development Computer Logix55XX ControlNet DH RIO Power Supply Ethernet x STR LTT J aa Allen Bradley a Law Lai ein J ROX X ControlNet amp gt gt f Connection J3 O S I KT connection DH PanelView 1400e Touch with 1784 KTCX15 or 1784 KTCS card ae sae 1786 TPS 52 Coaxial cable N Ny y ol 25043 Publication 2711E UM003B EN P 2 12 Working with the PanelView e Transfer Utility 32 Publication 2711E UM003B EN P Remote I O Pass Through Transfers The Remote I O Pass Through feature enables you to download a PanelBuilder Remote I O application file from your computer over the Data Highway Plus DH ControlNet or Ethernet networks and then over the Remote I O network to a PanelView terminal You can do this withou
2. The Transfer Utility s download upload dialog box is displayed Exiting the PanelView e When you have finished transferring applications exit the Transfer Transfer Utility 32 Utility To exit the Transfer Utility gt Choose Close from the File menu press ALT F4 or click the Close button Publication 2711E UM003B EN P Starting the PanelView 1400e Transfer Utility Version 3 FTU Working with the PanelView e Transfer Utility 32 2 29 The Panel View 1200 1400e Transfer Utility Version 3 FTU includes two utilities that can be accessed from the same icon the Transfer Utility for the PanelView 1000e 1200e 1400e terminals that is activated from toolbar buttons the PanelView 1200 Transfer Utility that can be selected from the Transfer menu bar This section describes how to start the program from Windows 3 x and Windows 95 Screen illustrations in this manual are from the Windows 3 1 environment Functionality of the transfer utility is the same for Windows 3 x and Windows 95 To start FTU from Windows 3 x 1 Double click the PanelBuilder 1400e program group or the program group you selected when you installed the software 2 Double click the Panel View 1200 1400e Transfer Utility icon If you have problems running the File Transfer Utility check the Readme txt file for potential system conflicts and contact Allen Bradley Technical Support For Technical Support information see the Preface in th
3. Important The application file to be uploaded must be the Current Application in the PanelView terminal For more information refer to Selecting an Application in Chapter 5 Configuring PanelView Terminals in your Panel View 1000e 1200e and 1400e Operator Terminals User Manual Publication Number 2711E 6 17 To prepare the PanelView terminal for a network or Remote I O Pass Through upload 1 Ensure the application file to be uploaded is the Current Application in the Panel View terminal The Current Application is a file that is currently selected and running on the Panel View terminal If you do not want to make changes to the Current Application s transfer parameters follow the next procedure to configure the Transfer Utility for an upload If you want to change the Current Application s transfer parameters switch the Panel View terminal to Configure mode using the hardware keyswitch or the Goto Configure Mode button Uploading 1000e 1200e 1400e Application Files and Alarm History Files 2 In the Terminal Configuration screen choose the Terminal Network Setup button to display the Terminal Network Setup screen For DH applications you can change both the baud rate and the terminal network address Terminal Network Setup Network Type DH Terminal Network Address 57 6K 0 77 octal Baud Rate Station Timeout msec Enabled 70 3000 Yes cot For ControlNet applications you
4. See solutions for items marked in the previous table Possible corrupt application file Try backup file or demo file Serial cable becomes disconnected during a serial download Ensure the serial cable is properly connected and try the download again 6 10 Troubleshooting for the PanelView e Transfer Utility 32 Message Cause What to do Might not be accessing COM port Check other program or devices that use the COM port and ensure that they do not conflict with the interrupt request IRQ or the COM settings Parity error detected Serial cable becomes disconnected during Ensure the serial cable is properly a serial download connected and try the download again Cannot obtain com port The wrong COM port has been chosen with the native serial driver either Serial 1 or Serial 2 Select the correct COM port The COM portis assigned to an enabled INTERCHANGE port and is trying to be used with the native serial driver Serial 1 or Serial 2 Choose the INTERCHANGE port Or disable INTERCHANGE reboot and choose the native serial driver Unable to communicate with terminal During a serial upload download the PanelView terminal is not in the Transfer Application screen Check that you are in configure mode On the PanelView terminal check that you are in the Transfer Application screen and you have selected the Serial tab Wrong baud rate Check that the baud rate p
5. Multiple DH Networks Connected by a Pyramid Integrator PI The format of the transfer path on a remote DH network is Transfer Path Format Valid Entries ll rrrrr ss I local PI address 0 77 octal rrrrr PI Link number 0 65535 decimal ss PanelView address on remote DH 0 77 octal The Pyramid Integrator PI Link number for each DH network must be unique Use your PI Programming Software to configure link numbers A PI chassis contains one RM module with two network channels It can also contain up to four KA modules each with two network channels Using the RM and four KA modules the Panel View e Transfer Utility 32 can transfer files on any or all of 10 DH networks The figure on the following page shows a development computer connected to a DH network The PI routes file transfers among four DH networks The valid transfer paths for the various Panel View terminals in the figure are PanelView Address Valid Transfer Path 12 12 3 6 2 3 23 6 3 23 10 6 4 10 Constructing the Transfer Path A 5 Figure A 2 Multiple DH Networks Connected by a PI Link PI Chassis Bridge Address PanelView 1400e Terminal Link 3 PanelView 1400e Terminal Link 2 PanelView 1400e Terminal Link 1 PanelView 1400e Terminal Development Computer Index Publication 2711E 6 16 Symbols csv file 3 8 pvd file 1 3 Numbers 1770 KF2 2 4 1770 K
6. 4 Using the hardware keyswitch or the Goto Configure Mode button switch the PanelView terminal to the Configure mode In the Terminal Configuration screen choose the Transfer Setup button to display the Transfer Setup screen Transter Setup Serial Network F17 F18 Baud Rate F1 F2 Error F3 Cancel OK F15 F16 To change the settings choose the Baud Rate Parity or Error buttons to move the check mark to the setting you want Baud Rate The speed at which data is transmitted over the serial cable The default setting for a serial transfer is 9600 baud e Parity Used to check for accurate transmission of the data between the development computer and terminal The default setting is None e Error Used to check for errors in the data transmission Error transmission is either CRC cyclical or cyclic redundancy check BCC block check character BCC is the default setting The settings that are defined in the Transfer Setup screen must match the Transfer Utility s settings When you have selected the required settings choose OK to exit this screen Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 3 5 To transfer an application serially in the Terminal Configuration screen choose the Transfer Application button to display the Transfer Application screen Transter Application Serial Memory Card F17 F18 Ready for Transfer
7. recommends that you close all open Windows applications If you have done that choose Next In the registration window enter the required information Registration information is on the software registration card included with your PanelBuilder 1400e package Choose Next Choose the drive and directory in which the FTU will be installed By default this is C AB PB1400E FTU To change the destination drive or directory type the new drive and or directory in the Program Files field Then choose Next Choose the program folder program group in which you want to install the FTU s icons which include a Readme file icon the Transfer Utility icon and an Uninstall icon By default the icons are installed in the PanelBuilder 1400e program folder Then choose Next Choose whether the installation utility will modify the AUTOEXEC BAT file The entry C RSI CMN is required in the PATH variable for the FTU to work correctly Then choose Next The setup utility shows a summary of the choices you made in the preceding dialog boxes To make any changes choose the Back button Otherwise choose Next to begin the installation Installing the FTU32 from the PanelView 1200 1400e Transfer Utilities CD on Windows NT or Windows 95 Working with the PanelView e Transfer Utility 32 2 23 13 After all the applications have completed installing you are prompted to reboot your computer You can reboot immediately or later
8. 4 2 He o Alarm History files Transferring application files downloading 1 3 illustrations 2 12 types of files 1 3 uploading 1 3 Troubleshooting 6 1 U Upload application selection from menu 3 6 3 14 Upload Download cable 2 3 5 9 5 11 5 15 Uploading 1 3 Alarm History files 1 3 DH RIO Pass Through 1 4 tips 1 4 1 7 W WINtelligent LINX drivers 1 7 port selected 5 11 5 14 Reach us now at www rockwellautomation com Wherever you need us Rockwell Automation brings together leading brands in industrial automation including Allen Bradley controls Reliance Electric power transmission products Dodge mechanical power transmission components and Rockwell Software Rockwell Automation s unique flexible approach to helping customers achieve a competitive advantage is supported by thousands of authorized partners distributors and system integrators around the world Allen Bradley EELANCEIS DODGE Americas Headquarters 1201 South Second Street Milwaukee WI 53204 USA Tel 1 414 382 2000 Fax 1 414 382 4444 ROCKWELL ES R kw Ii European Headquarters SA NV avenue Herrmann Debroux 46 1160 Brussels Belgium Tel 32 2 663 06 00 Fax 32 2 663 06 40 oc e Asia Pacific Headquarters 27 F Citicorp Centre 18 Whitfield Road Causeway Bay Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Automation Publication 2711E UM003B EN P September 2001 PN 410
9. Warning 3103 PCMCIA card ejected The card is ejected from the PanelView Insert the PCMCIA card into the PanelView Error 3108 terminal terminal or select another terminal storage area Then try the transfer again The download file already exists on the PanelView terminal Do you want to overwrite it on the PanelView terminal An application with the same name may already exist in the PanelView terminal Choose Yes to overwrite the download file on the PanelView terminal Choose No to cancel the file transfer Warning 3111 PCMCIA card is write protected The card is write protected Disable write protection Or select another Error 3114 Storage area Alarm History is empty therefore no file was You cannot upload an empty alarm history Wait for alarm entries in the alarm history uploaded file file Warning 3120 The download file already exists on the PanelView terminal Do you want to overwrite it on the PanelView terminal and make the application current Warning 3121 Either an application with an identical name already exists in the PanelView terminal or there is not enough space or you did not choose to make the application current Choose Yes to overwrite the application file on the PanelView terminal and make the application current Choose No to cancel the file transfer 6 4 Troubleshooting for the PanelView e Transfer Utility 32 pvd File Errors Use the following table
10. be downloaded is compatible with the terminal The application must be made current Choose Yes to continue the Make Current option is automatically selected Choose No to cancel Driver Errors Problem Troubleshooting for the PanelView e Transfer Utility 32 6 9 Cause Use the following table to identify Transfer Utility problems you may encounter due to driver selection What to do The Rockwell Software RSLinx communication software is not currently running This software package is required in order to perform file transfers Error 4300 RSLinx communication software is not installed Install R SLinx The selected driver is a Rockwell Software RSLinx network driver Use the RSLinx software package in order to configure the communication network driver Error 4331 The driver in RSLinx is not configured Use the RSLinx communication software to configure the driver Incorrect routing address could corrupt data ina non PanelView device Verify the correct address has been specified Do you want to continue Warning 4332 This will occur for network and Remote 1 0 transfers The routing address may be incorrect Check that the address is correct Choose Yes to continue Choose No to cancel The driver is not properly configured Check whether RSLinx is installed or how the driver is configured Error 4333 The third party RS Linx communication package may not
11. refer to the PanelView 1000e 1200e and 1400e Operator Terminals User Manual Publication Number 2711E 6 17 Remote I O Pass Through Using Remote I O Pass Through you can upload application files and Alarm History files over Remote I O and then over DH ControlNet or Ethernet You can download a Remote I O application between the Panel View terminal and computer without taking the terminal out of Run mode or changing the terminal s serial cabling Since the serial port is not used for Remote I O Pass Through transfers you can print from the Panel View terminal without changing the serial cabling of the terminal To do Remote I O Pass Through downloads you can use RSLinx drivers RSLinx is included with your Transfer Utility software package however you must install RSLinx separately Refer to the table in Chapter 5 for a complete list of hardware and driver requirements Read this section when preparing to perform an application file transfer General e For application file transfers over ControlNet or DH be sure the Panel View terminal address is correct or for file transfers over Remote I O Pass Through be sure the terminal address and control byte are correct otherwise the transfer could corrupt data used by another device on the network such as the PLC e For application file transfers serial or network the communication parameters of the Panel View e Transfer Utility 32 driver must match those being us
12. 1200e 1400e Application Files and Alarm History Files This chapter describes how to upload Panel View application files and alarm history files from the PanelView terminal to your computer using the various transfer methods You can upload application files using either a serial connection a network connection or a Remote I O connection For serial transfers you must connect the Panel View terminal to a computer with the Upload Download cable Allen Bradley Catalog Numbers 2706 NC13 2711 NC13 2711 NC14 for PanelView 1000e terminals 2711 NC1 for Panel View 1200e 1400e terminals For network transfers you must connect the PanelView terminal to the computer over a DH or ControlNet network For Remote I O transfers you must connect the Panel View terminal to the PLC over a Remote I O network and connect the PLC to the computer over a DH ControlNet or Ethernet network To upload application files you must complete these steps in order e prepare the PanelView terminal for a serial network or RIO Pass Through upload Important For network uploads you do not need to configure the parameters on the Panel View terminal PanelView uses the parameter settings for the currently selected file e configure the PanelView e Transfer Utility 32 for the upload e initiate the application file upload 3 2 Uploading 1000e 1200e 1400e Application Files and Alarm History Files To prepare the PanelView terminal for a serial upload 1
13. Select another terminal storage area and try again Or check that the download file is not made current and try again There is no current selected application on the PanelView terminal for uploading Error 4228 There is no selected application running in the PanelView terminal for uploading Make sure you select the correct application file on the PanelView terminal There is not enough disk space for the uploaded application Error 4229 There is not enough disk space to store uploaded applications Select another disk or free some space on the current disk This version firmware s does not support upload alarm history Error 4230 The current P anelView firmware does not support uploading alarm history data Make sure you have firmware version 2 or later The file s already exists Do you want to overwrite it Warning 4232 An application with an identical name already exists in that upload directory Choose Yes to overwrite the file Choose No to cancel RSLinx version 2 0 or greater must be installed to execute the Station Browse functionality Error 4233 You do not have RS Linx Version 2 or later Install RSLinx Version 2 or later The application to be downloaded must be made current Do you want to continue Warning 4234 The user has not selected the Make Current option the PanelView terminal does not have an application selected and the file to
14. as the transfer method the driver is the only option you can configure end Sema Greci Tiarate beacon Daor ddj Fariba ted bestrter mra FE aed Flores isreny wis 2 peel 0 FT connection re atl Dako s Toria Denver Sana 2 Fanei iew Temirai CH Erias Ba he banged Fae ipa Deiridh 1 Seba bo math yor PE p peed prag E inie Taming Coniigunebaa reje jai in Fhar H gadel 4 Dap rgthe Trais ppicsion green bo pasos seisi kargie repai To select the driver 1 Click the Refresh List button to refresh the list of drivers 2 Select a serial driver from the list of available drivers Serial 2 Driver options are Serial 1 or Serial 2 Serial 1 and Serial 2 drivers enable you to configure two different serial setups for example baud rates Also they can accommodate the two communication ports on many computers Refer to the physical communication ports on your computer to determine the correct port for your application Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 5 9 3 Select the Configure Driver button For Serial 1 or Serial 2 the Communication Driver Configuration dialog box appears Communication Onver Condiquration Diba Serial 7 Bayt e z Faiy Eii Pot om e e m pe T Even i CAC 4 Define the settings in the Communication Driver Configuration dialog box as follows Baud Specify the data transfer rate between your computer and the PanelView terminal This must
15. be installed Install R SLinx The RS Linx driver used for the transfer may not be configured properly Use the RSLinx communication software to configure the driver No selection was made from the Station Browser Error 4340 A device was not selected in Station Browse Select a device in Station Browse or press Cancel The selection must be a Pass Through device e g PLC or ControlLogix RIO Module for RIO Pass Through transfers Error 4341 An invalid device was selected Select a Pass Through device or press Cancel The selection must be a PanelView terminal for network transfers Error 4342 An invalid device was selected Select a PanelView terminal or press Cancel PanelView 1400e Transfer Utility Error Messages FTU Version 3 Message Cause Consult the following table to identify and respond to some common error messages that can appear on the screen when you upload or download data or upload Alarm History files What to do Data received too fast from PanelView terminal Upload speed too high Reduce baud rate Invalid baud Might not be accessing COM port Check other program or devices that use the COM port If there is one check to see that the internal modem is turned off No response from PanelView terminal Baud rate too high Reduce baud rate Other possible causes are the same as the items marked in the previous table
16. be started For PV 1200 Upload Download configurations refer to PV 1200 Transfer Utility Manual publication 2711 UM010B EN P The following information and table will help you determine which driver packages and drivers you need for your particular system configuration and what the appropriate transfer link will be for your communication hardware setup You need to know e what hardware you have e what transfer link you re using e which driver package you re using e which driver options must be configured Table 5 A provides a matrix to help determine your hardware and driver requirements For DF1 Direct transfers choose the internal drivers Serial 1 or Serial 2 For DH use RSLinx if you do not have RSLinx use the Serial 1 or Serial 2 driver to communicate over the KF2 module For ControlNet use RSLinx if you do not have RSLinx use the Serial 1 or Serial 2 driver to communicate over the KFC module For Remote I O Pass Through use whichever driver you would use for DH ControlNet or Ethernet Note Modbus supports only serial transfers 5 2 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Communication FTU32 Version 5 Transfer Method Table 5 A Table of PC Host Hardware and Applicable Drivers Network Accessed Driver Packages Corresponding Driver Hardware and Transfer Path PC COM Port RS 232 Serial DF1 Di
17. but you must reboot before you can run the Transfer Utility or other applications successfully If you want to upload or download Panel View files over the PLC networks after you finish installing the Transfer Utility you also need to install INTERCHANGE or WINtelligent LINX software If you do not have this software contact Allen Bradley Technical Support for assistance Do not cancel the installation while it is in progress If you want to undo the installation let the installation finish then use Uninstall Transfer Utility to remove all the installed files and to update the Windows registry For information on how to start and exit from the Panel View 1200 1400e Transfer Utility see the PanelView 1200 1400e Transfer Utility User Manual A B Publication Number 2711E 6 8 Panel View e Transfer Utility 32 FTU32 Version 5 is provided in the Transfer Utility kit A B Catalog Number 2711E ND7 on CD You can create your own 3 5 inch floppy disks from the CD For instructions on how to create floppy disks of the software from the CD refer to the Floppies txt file in the root directory of the PanelBuilder 1400e CD To install the FTU32 1 Start Windows NT or Windows 95 If you re already in Windows close all open Windows applications 2 Insert the CD in the drive 3 Browse the CD for file FTU_V5 Browse Disk 1 Run SETUP EXE 4 The Welcome dialog box for the Transfer Utility recommends that you close all
18. can change the terminal network address not the baud rate The first screen shows the Terminal Network Setup screen for ControlNet KTCX application with no scheduled tags assigned The second screen shows the Terminal Network Setup screen for ControlNet KTCS application with scheduled tags assigned Terminal Network Setup Network Type ControlNet KTCX Terminal Network Address ET Station Timeout msec Enabled 68 3000 Yes Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 5 Terminal Network Setup Network Type ControlNet KTCS Terminal Network Address ET Prey F20 Next F21 For Remote I O applications you can change the baud rate The following shows the Terminal Network Setup screen for a Remote I O application Terminal Network Setup Network Type Remote I O Device Type PLC 5 15 integral Baud Rate F1 File Rack Word Byte Usage Size Access 1 0 Low Write 24 Full 2 1 Low Write 24 Full 3 2 Low Write 24 Full 4 0 Low Read 24 Full Block Transfer Files F3 Pass Through Control Byte Rack 3 Word 7 Byte Cancel OK F15 F16 3 When you have selected the required settings choose OK to exit the screen 4 Switch the Panel View terminal to Run mode The application starts to run You can now transfer application files over the selected network Uploading 1000e 1200e 1400e Application Files and Alarm History Files To co
19. corrupt data used by another device on the network such as the PLC You can download files using either a serial connection a network connection or a Remote I O connection For serial transfers you must connect the PanelView terminal to a computer with the Upload Download cable Allen Bradley Catalog Numbers 2706 NC13 2711 NC13 2711 NC14 for PanelView 1000e terminals 2711 NC1 for PanelView 1200e 1400e terminals For network transfers you must connect the PanelView terminal to the computer over a DH or ControlNet network For Remote I O transfers you must connect the Panel View terminal to the PLC over a Remote I O network and connect the PLC to the computer over a DH ControlNet or Ethernet network To download application files you must complete these steps in order e prepare the PanelView terminal for the download This section explains how to prepare a Panel View terminal for a serial network or Remote I O Pass Through download e configure the PanelView e Transfer Utility 32 for the download e initiate the application file download 4 2 Downloading 1000e 1200e 1400e Application Files To prepare the PanelView terminal for a serial download 1 4 Using the hardware keyswitch or the Goto Configure Mode button switch the PanelView terminal to the Configure mode In the Terminal Configuration screen choose the Transfer Setup button to display the Transfer Setup screen Transter Setup Serial Netw
20. match the baud rate configured for the PanelView terminal The default setting is 9600 Port Specify COM1 COM2 COM3 or COM4 as the serial port used to connect the serial cable to the PanelView terminal The default setting is COM1 Parity Specify None or Even for the type of error checking to be used This must match the parity configured for the PanelView terminal The default setting is None Error Specify the error detection protocol used by the device BCC is Block Check Character and CRC is Cyclic Redundancy Check This must match the error checking protocol configured for the PanelView terminal The default setting is BCC For details about PanelView terminal transfer configuration settings see Transferring Application Files in Chapter 5 Configuring PanelView Terminals in your Panel View 1000e 1200e and 1400e Operator Terminals User Manual Publication Number 2711E 6 17 5 10 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Network Transfer Method Network and Driver Configuration When you select Network as the transfer method Network Accessed Driver and Transfer Path are the options you can configure Teanga dels bevesen your PE are b Paneer honni en 4 imal i rete Mulls rairai can ba connected vis badger call i Select 4 Hehagk inser Hamak doosist bH Taci Spach the naket fo eheh pour PE Smail fathead bp aed abet askark dha tal be cued bor p
21. on your hard drive for the FTU32 and copies all necessary files to it By default the drive and directory is C AB PB 1400E FTU32 You can change this default You can also create your own floppy disks of the Panel View e Transfer Utility 32 software from the CD this manual was on For instructions on how to create floppy disks of the software from the CD refer to the Floppies txt file in the root directory of the CD To install FTU32 1 Start Windows 2000 SP2 NT 95 If you re already in Windows close all open Windows applications Insert the CD ROM in the drive The CD ROM begins to run automatically If the install does not start automatically choose Run from the Start button and select setup exe from the CD ROM drive or select setup exe from Windows Explorer In the Welcome dialog box choose Next If you are installing on Windows 95 the Select Version dialog box appears Trees Whi dba Deski be itera ree koe ade etc ere Publication 2711E UM003B EN P 2 18 Working with the PanelView e Transfer Utility 32 Publication 2711E UM003B EN P The CD ROM includes two install versions for the Transfer Utility software e Version 3 This version offers you the Transfer Utility for Windows 3 1 or later or Windows 95 Version 3 supports Panel View application file transfers over networks using INTERCHANGE and WINtelligent LINX software drivers e Version 5 This version offers you the Transfer Utility for W
22. pvd file from which you want to get the values for the communication parameters or choose Browse to find the pvd file 3 Click Preview Contents to view the communication parameters of the pvd file you have selected Burie FAY Fie Funders Fila E Appr keh FH aries pra Eroen Broene Spari te wiring Parole aniraa ie iron tich cormnericaion parte ae lo ae aSa PM Eraghth Larabee Teria Tipe Farra 130e beach gii Tegai Fees 10 red atayan Fiama LA ippinsion PseT bacugh asi Her T Pi AiD Bari 57E Flees Pach Though ease FLOSS niigi Tanira Be Dindir Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 5 7 4 Click Apply The transfer path network type and driver values from the pvd file are placed in the appropriate boxes in the Configure Transfer Method dialog box If you are performing a Remote I O Pass Through transfer the Pass Through device type rack word and byte values from the pvd file are placed in the appropriate boxes in the Configure Transfer Method dialog box The transfer method is entered in the main download upload dialog box If you selected Application as your transfer method do not exit using OK or Apply Instead click Close Clicking OK or Apply removes Application as your transfer method Configure Transfer Parameters Manually 1 For uploads select Serial Network or Remote I O Pass Through from the drop down list box For downloads select Seria
23. s alarm history serially in the Terminal Configuration screen choose the Transfer Application button to display the Transfer Application screen Transter Application Serial Memory Card F17 F18 Ready for Transfer To prepare the PanelView terminal for a network or Remote I O Pass Through upload 1 Ensure the alarm history file to be uploaded is the Current Application in the Panel View terminal The Current Application is a file that is currently selected and running on the Panel View terminal If you do not want to make changes to the Current Application s transfer parameters follow the next procedure to configure the Transfer Utility for an upload If you want to change the Current Application s transfer parameters switch the Panel View terminal to Configure mode using the hardware keyswitch or the Goto Configure Mode button 3 12 Uploading 1000e 1200e 1400e Application Files and Alarm History Files 2 In the Terminal Configuration screen choose the Terminal Network Setup button to display the Terminal Network Setup screen For DH application files you can change both the baud rate and the terminal network address Terminal Network Setup Network Type DH Terminal Network Address 57 6K 0 77 octal Baud Rate Station Timeout msec Enabled 70 3000 Yes For ControlNet application files you can change the terminal network address not the baud rate The first screen shows the Terminal
24. specified upload directory S cannot be used as a valid upload destination Ensure that it is not write protected and there is sufficient disk space on the drive If necessary free up some disk space and try again Error 4124 The upload location either does not exist is write protected or does not have enough space Check that the location exists and is not write protected or free up some space and try again Troubleshooting for the PanelView e Transfer Utility 32 6 5 Problem Cause What to do Unable to read application header details from The runtime application may be corrupt Ensure your file is a pvd file and that it is the PVD file s not corrupted This file may be corrupt or incorrectly used Error 4126 Unable to read file transfer details from the PVD The runtime application may be corrupt Ensure your file is a pvd file and that it is file s not corrupted This file may be corrupt or incorrectly used Error 4127 The upload destination directory is blank You must specify a directory to upload to Enter an upload destination or press Enter a valid upload directory path Browse to search for one and try again Error 4128 Some of the alarms may not be acknowledged You have chosen to clear the alarms in the Choose Yes to clear the alarms Choose No Do you still want to clear the uploaded alarms alarm history after uploading to not clear the alarms from the
25. terminal s Alarm History screen Warning 4130 The transfer parameters in the application file to The transfer method is Application and the Load the pvd file in PanelBuilder Check be downloaded are invalid file that you are downloading does not have thatthe transfer parameters are set up Error 4131 the transfer parameters set up properly properly in PanelBuilder for example the Pass Through Control Byte has been defined ibili se the following table to identi ransfer Utility problems you Compatibility Errors Use the following table to identify Transfer Utility problems y may encounter due to incompatibility between the pvd file and the Panel View terminal Problem Cause What to do Transfer inhibit bit is set The application that is running on the Check the PLC inhibit bit and reset the bit Error 4200 PanelView terminal may be inhibiting file transfers No Remote I O driver found on PanelView A required Remote I O driver is not installed Choose Yes to continue Choose No to terminal in the PanelView terminal cancel the file transfer The application will The download application cannot be made not be selected current when download completes Do you want to continue Warning 4201 No DH driver found on PanelView terminal A required DH driver is not installed in the Choose Yes to continue Choose No to The download application cannot be made PanelView terminal cancel the file transfer The application
26. the following items that were originally in the downloaded application are not uploaded unused nodes unused scan classes unused tags unused tag folders unused graphic images tag descriptions variable names comments in expressions unused scheduled files When the PanelView e Transfer Utility 32 uploads an application file it creates a pvd file PanelBuilder can open the pvd file to create a pvc file When pvd files are opened in PanelBuilder the pvd files are always regenerated as pvc files with a private tag database Introducing the PanelView e Transfer Utility 32 FTU Version 3 PanelView e Transfer Utility 32 and RSLinx The Transfer Utility supports RSLinx network drivers RSLinx Lite Version 2 0 or later is included with your PanelBuilder 1400e software package A B Catalog Number 2711E ND1 or Transfer Utility software package A B Catalog Number 2711E ND7 The Panel View e Transfer Utility 32 supports a subset of the RSLinx drivers which are used by DH or ControlNet You can use these drivers to transfer files over DH ControlNet Remote I O Pass Through or serial connection networks For more information refer to the RSLinx user documentation If you use RSLinx drivers install them before setting up communications for application file transfers The Panel View e Transfer Utility 32 displays the RSLinx drivers as driver options but you can use them only if they are installed Make sure the dr
27. the Transfer Utility to configure your selected driver Refer to the WINtelligent LINX for Allen Bradley Programmable Controllers User s Guide Publication Number 9352 WABUG for complete information Important The PanelView 1200 1400e Transfer Utility works with INTERCHANGE only WINtelligent LINX only or with both INTERCHANGE and WINtelligent LINX installed on the same computer System Requirements Chapter 2 Working with the PanelView e Transfer Utility 32 This chapter provides instructions for setting up and using the Panel View e Transfer Utility 32 including e minimum hardware and software requirements e installing and starting the PanelView e Transfer Utility 32 e exiting from the PanelView e Transfer Utility 32 The Panel View e Transfer Utility 32 has context sensitive online help that you can access at any time by pressing the Help button F1 on your keyboard or by clicking the Help menu item You can also click the icon SS in the utility s toolbar Auto Help automatically displays help information as you work with the utility from one application window to another For version information and information about obtaining technical support click the icon r in the utility s toolbar You need the following hardware and software to install the PanelView e Transfer Utility 32 Table 2 A Hardware and Software Requirements System Requirements Hardware A personal computer with a 66 MHz 486 DX or h
28. to identify Transfer Utility problems you may encounter due to pvd files In the following error or warning messages s is the name of the file Problem Cause What to do Unable to access specified file s Cause An unspecified error occurred 01 Error 4100 The specified application file cannot be read Ensure the specified application file exists and is not corrupted The upload download destination may not be valid or is write protected Ensure the path is correct and that it is not write protected Unable to access specified file s Cause The file could not be located 02 Error 4100 The specified application file cannot be read Ensure the specified application file exists and is not corrupted The upload download destination may not be valid or is write protected Ensure the path is correct and that it is not write protected Unable to access specified file s Cause All or part of the path is invalid 03 Error 4100 The path or file name is invalid Ensure the path and file name is correct and exists Unable to access specified file s Cause The file could not be accessed 05 Error 4100 The file is read only Either change the location change the file name or change the file properties to make the file writeable Unable to access specified file s Cause The disk is full 13 Error 4100 There is not enough disk
29. 0 KF2 1785 KE e 1784 KL 1784 KT e 1784 KT2 e 1784 KTK1 1784 PCMK e 1784 KTX You can transfer applications over a DH network using RSLinx drivers or Serial or Serial 2 drivers if the transfer is over a KF2 module To download over a DH network the development computer and Panel View terminal can be on the same network or on two different bridged DH networks File transfers over one ControlLogix bridge can be supported You can transfer files from the development computer over a DH ControlNet or Ethernet network to a ControlLogix gateway module and then bridged to the Panel View terminal over a DH or ControlNet network ControlLogix gateway modules are 1756 DH RIO 1756 CNB and 1756 ENET Working with the PanelView e Transfer Utility 32 2 5 Figure 2 2 DH Network Download with KF2 Development Computer E TANIA 1770 KF2 MAT RS 232 Serial Port RS 232 _ 9 pin 25 pin RS 232 link 25038 Publication 2711E UM003B EN P 2 6 Working with the PanelView e Transfer Utility 32 Figure 2 3 DH Network Download with 1784 KT card Development Computer MMUVNNHUNAL MAA PanelView 1400e 1784 CP Cable DH 25039 Publication 2711E UM003B EN P Working with the PanelView e Transfer Utility 32 2 7 Figure 2 4 DH Network Download with Logix55xx Dev
30. 1000e 1200e 1400e Application Files 4 7 To configure the PanelView e Transfer Utility 32 for the download 1 In the PanelView e Transfer Utility 32 choose the Download tab from the main dialog box T PanelView e Transfer Utility 32 Eile Transfer Method Parameters Options View Help fe gt S JE 3 system Be Teh cg l ahi Download Upload Source Download Destination File E AppFiles FileName pvd Terminal Storage Memory Partition 2 z Specify file to download Specify target partition in terminal to PV terminal Browse Transfer Method Select download method Serial X Configure Method Transfer Topology Currently Configured Download Options E Serial connection m Download from your PC to a P terminal via a direct serial connection Serial driver Serial 1 For Help press F1 NUM 7 2 In the Source File box type the full path and file name of the download file or choose Browse to locate a file on the disk The file must be a pvd file created by PanelBuilder 1400e A pvd file may already be displayed in the Source File box If you started the Transfer Utility from PanelBuilder 1400e the source file defaults to the current application in PanelBuilder If you started the Transfer Utility separately the source file defaults to the last source file you had saved using Auto Save All Settings 3 In the Terminal Storage box choose the memory area whe
31. 11E K10C15 ControlNet 1 5 enhanced 2711E K10C6 terminal 1000e Keypad Termina 2711E T14C6 1400e Touch Screen Terminal Color display stud mount NEMA 4X indoor use only 2711E K14C6 1400e Keypad Terminal Color display stud mount NEMA 4X indoor use only 2711E T14C15 1400e Touch Screen Terminal ControlNet 1 5 enhanced 2711E T14C6 terminal 2711E K14C15 1400e Keypad Terminal ControlNet 1 5 enhanced 2711E K14C6 terminal 2711 NC1 Upload Download Cable For 1200e 1400e Series E and earlier terminals Includes a 9 pin to 25 pin RS 232 serial cable Upload Download cable to transfer files between terminal and development computer The cable is 10 ft 3 1 m long 2711 NC13 Upload Download Cable For 1000e 1400e Series F and later terminals Includes a 9 pin RS 232 serial cable Upload Download cable to transfer files between terminal and development computer The cable is 16 4 ft 5 m long 2711 NC14 Upload Download Cable For 1000e 1400e Series F and later terminals Includes a 9 pin RS 232 serial cable Upload Download cable to transfer files between terminal and development computer The cable is 32 7 ft 10 m long 2706 NC 13 Upload Download Cable For 1000e 1400e Series F and later terminals Includes a 9 pin RS 232 serial cable Upload Download cable to transfer files between terminal and development computer The cable is 10 ft 3 m long Publication 2711E UM00
32. 3B EN P Equipment Required for Transferring Applications Working with the PanelView e Transfer Utility 32 2 3 This section describes the equipment required to perform the following application transfers serial transfer e DH network transfer ControlNet network transfer Remote I O Pass Through transfer Serial Upload Download To transfer applications serially you need an RS 232 Serial Upload Download cable A B Catalog Numbers 2706 NC13 2711 NC13 2711 NC14 for Panel View 1000e 1400e Series F and later terminals 2711 NC1 for PanelView 1200e 1400e terminals Series E and earlier for connecting the computer to the Panel View terminal The Transfer Utility can transfer applications serially without using the RSLinx drivers Figure 2 1 Connecting the Upload Download Cable Computer running the PanelView e Transfer Utility PanelView 1400e Touch s Screen Terminal Let a x La ta ey v JOL z RS 232 9 pin RS 232 Upload Download Cable se seres or s 2711 NC13 series F or later PPINSengs E orearen 25037 2711 NC1 series E or earlier Publication 2711E UM003B EN P 2 4 Working with the PanelView e Transfer Utility 32 Publication 2711E UM003B EN P DH Network Transfers You need one of the following Allen Bradley Data Highway Plus DH interface modules installed in the development computer to transfer applications over a DH network e 177
33. 40 646 5801 for technical support between 8 AM and 5 pM EST Monday to Friday Allen Bradley provides support services worldwide with over 75 Sales Support Offices 512 authorized Distributors and 260 authorized Systems Integrators located throughout the United States alone plus Allen Bradley representatives in every major country in the world Local Product Support Contact your local Allen Bradley representative for sales and order support e product technical training e warranty support support service agreements The following conventions are used throughout this manual bulleted lists such as this one provide information not procedural steps numbered lists provide sequential steps or hierarchical information e italic type is used for emphasis textin this font indicates words or phrases you should type We also use this arrow to call attention to helpful information About the PanelView e File Transfer Utility 32 Chapter 1 Introducing the PanelView e Transfer Utility 32 This chapter introduces you to the PanelView e Transfer Utility 32 version 5 including e what the Transfer Utility is used for the methods of transferring application files tips for transferring files Use the PanelView e Transfer Utility 32 to transfer PanelBuilder application files between a computer and the Panel View terminal You can transfer application files created in PanelBuilder 1400e for Windows You
34. 61 138 01 2 Supersedes Publication 2711 E 6 16 November 1999 2001 Rockwell International Corporation Printed inthe U S A
35. 8 If you have this Decide which Select Network Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Choose one of these Select the corresponding driver communication transfer link to use Type and driver packages hardware Address 1784 KT KT2 PCMK Network Direct DH WIN LINX 1784 KT KT2 PCMK to DH WIN LINX using INTERCHANGE to DH INTERCHANGE Interchange Port 1 8 Remote 1 0 DH WIN LINX 1784 KT KT2 PCMK to DH Pass Through WIN LINX using INTERCHANGE to DH INTERCHANGE Interchange Port 1 8 1784 KTX Network Direct DH WIN LINX 1784 KTX to DH WIN LINX using INTERCHANGE to DH INTERCHANGE Interchange Port 1 8 Remote 1 0 DH WIN LINX 1784 KTX to DH Pass Through WIN LINX using INTERCHANGE to DH INTERCHANGE Interchange Port 1 8 SS Technologies Network Direct DH WIN LINX SS Technologies 5136 SD to DH 5136 5D Remote 1 0 DH WIN LINX SS Technologies 5136 SD to DH Pass Through SS Technologies Network Direct DH WIN LINX SS Technologies 5136 SD2 to DH DH 5136 5D2 Remote 1 0 DH WIN LINX SS Technologies 5136 SD2 to DH DH Pass Through 1770 KFC Network Direct ControlNet Internal File Transfer Serial 1 or 2 Utility WIN LINX 1770 KFC to ControlNet DH Mode WIN LINX using INTERCHANGE to ControlNet INTERCHANGE Interchange Port 1 8 Remote 1 0 ControlNet Internal File Transfer Serial 1 or 2 Pass Through Utility W
36. 9 starting FTU 2 29 Accessing PanelView e Transfer Utility 32 1 1 Icon PanelView e Transfer Utility 32 1 1 PanelView e Transfer Utility 32 about 1 1 Starting FTU32 2 26 Starting FTU32 from PanelBuilder 1400e 2 28 Panel View terminals catalog numbers 2 2 Parity 3 2 3 10 4 2 5 9 5 12 5 15 Pass Through Byte Definition Byte 5 16 Rack number 5 16 Word 5 16 Pass Through equipment required 2 12 PI Programming Software A 4 PLC logic corruption 1 4 4 1 Port selecting serial 5 9 5 11 5 15 Private tag database 1 5 Publication 2711E 6 16 Index Publication 2711E 6 16 Publications related P 2 Pyramid Integrator bridging DH networks A 4 R Rack assignments 1 5 Refresh List button 5 11 5 14 Remote station address DH A 1 RIO Pass Through 1 4 RM modules A 4 RSLinx 2 4 2 8 2 12 drivers 1 6 Invoke RSLinx 5 11 5 14 S Settings changing 3 2 3 10 4 2 Software requirements minimum 2 1 Starting Transfer Utility from PanelBuilder 1400e 2 28 from Windows 3 x 2 26 2 29 from Windows 95 2 29 Support services P 4 System requirements 2 1 T Technical support services P 4 Transfer Application screen doing serial transfers 3 3 3 11 4 2 Transfer link selecting 5 1 Transfer method selecting 5 5 Transfer Setup screen 3 2 3 10
37. Allen Bradley PanelView e Transfer Utility Cat No 2711E ND7 User M anual Automation Important User Information Because of the variety of uses for the products described in this publication those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements including any applicable laws regulations codes and standards The illustrations charts sample programs and layout examples shown in this guide are intended solely for purposes of example Since there are many variables and requirements associated with any particular installation Allen Bradley does not assume responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication Allen Bradley publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Allen Bradley office describes some important differences between solid state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication Reproduction of the contents of this copyrighted publication in whole or part without written permission of Rockwell Automation is prohibited Throughout this manual we use notes to make yo
38. FC 2 8 1784 KL 2 4 1784 KTC 2 8 1784 KTCX 2 8 1784 KTK1 2 4 1784 KT 2 4 1784 KT2 2 4 1784 KTX 2 4 1784 PCMK 2 4 1785 KA A 2 bridging DH networks A 2 1785 KE 2 4 A Alarm History configuring communications 5 4 record 3 8 uploading 3 10 Alarm trigger value 3 9 Allen Bradley PI Programming Software A 4 Application downloading tips 1 4 1 7 uploading tips 1 4 1 7 AUTOEXEC BAT file 2 20 2 22 2 24 2 25 B Baud rate 5 9 5 11 5 14 default 3 2 3 10 4 2 BCC error detection protocol 5 9 5 16 Block Check Character See BCC Bridged DH networks with 1785 KA A 2 with Pyramid Integrator A 4 C Communication Driver Configuration dialog box 5 9 5 11 5 14 Communications settings saving 5 16 ControlLogix bridging 2 4 2 8 ControlNet direct transfers 2 8 equipment required for transfer 2 12 selecting driver 5 1 ControlNet addressing local station address A 1 Logix55xx address A 1 CRC error detection protocol 5 9 5 12 5 15 5 16 Cyclic Redundancy Check See CRC D Data Transmission errors 3 2 3 10 4 2 Devices local station addressing A 1 Logix55xx addressing A 1 remote station address A 1 DH 2 4 equipment required for transfer 2 12 Pass Through transfers 2 12 remote station address bridged by 1785 KA A 2 bridged by Pyramid Integrato
39. Firmware version incompatibility Check firmware version compatibility Obtain the PanelView terminal version from the Terminal Configuration screen Refer to Appendix E Version Control in the PanelBuilder 1400e Configuration Software for Windows User Manual Terminal type incompatibility keypad application versus touch screen applications Check terminal type Obtain this information from the Application window inside the PanelBuilder window Messages General Types of Messages Troubleshooting for the PanelView e Transfer Utility 32 Cause What to do Communications hardware or driver not present Check for supported communications network information which resides in the PanelView terminal by pressing the Terminal Information button on the Terminal Configuration screen For details see Chapter 5 in the PanelView 1000e 1200e and 1400e Operator Terminals User Manual For ControlNet check that the KTCX card is installed in the terminal By default Remote 1 0 ControlNet and DH drivers are the available drivers To install another driver use the Serial Firmware Upgrade Utility KTC Control Net Driver Card did not go online ControlNet Version 1 5 KTC card is not ControlNet Version 1 5 is currently not Perhaps network keeper is inoperative recognized by WINtelligent LINX supported Use ControlNet Version 1 25 until further notice Driver Serial 1 Cannot obt
40. IN LINX 1770 KFC to ControlNet DH Mode WIN LINX using INTERCHANGE to ControlNet INTERCHANGE Interchange Port 1 8 1784 KTC Network Direct ControlNet WIN LINX 1784 KTC to ControlNet DH Mode WIN LINX using INTERCHANGE to ControlNet INTERCHANGE Interchange Port 1 8 Remote 1 0 ControlNet WIN LINX 1784 KTC to ControlNet DH Mode Pass Through WIN LINX using INTERCHANGE to ControlNet INTERCHANGE Interchange Port 1 8 5 4 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers If you have this Decide which Select Network Choose one of these Select the corresponding driver communication transfer link to use Type and driver packages hardware Address 1784 KTCX Network Direct ControlNet WIN LINX 1784 KTC to ControlNet DH Mode WIN LINX using INTERCHANGE to ControlNet INTERCHANGE Interchange Port 1 8 Remote 1 0 ControlNet WIN LINX 1784 KTC to ControlNet DH Mode Pass Through WIN LINX using INTERCHANGE to ControlNet INTERCHANGE Interchange Port 1 8 Configuring Communications The procedure and dialog boxes are the same for application downloads application uploads and alarm history uploads Configuring communication settings involves the following steps e selecting the transfer method e configuring the transfer parameters e saving the communication settings Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 5 5 Sel
41. Network Setup screen for ControlNet KTCX alarm history file with no scheduled tags assigned The second screen shows the Terminal Network Setup screen for ControlNet KTCS application file with scheduled tags assigned Terminal Network Setup Network Type ControlNet KTCX Terminal Network Address RET 1 99 decimal Station Timeout msec Enabled Cancel OK F15 F16 Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 13 Terminal Network Setup Network Type ControlNet KTCS Terminal Network Address ET Prey F20 Next F21 For Remote I O application files you can change the baud rate The following shows the Terminal Network Setup screen for a Remote I O application file Terminal Network Setup Network Type Remote I O Device Type PLC 5 15 integral Baud Rate F1 File Rack Word Byte Usage Size Access 1 0 Low Write 24 Full 2 1 Low Write 24 Full 3 2 Low Write 24 Full 4 0 Low Read 24 Full Block Transfer Files F3 Pass Through Control Byte Rack 3 Word 7 Byte Low Cancel OK F15 F16 3 When you have selected the required settings choose OK to exit the screen 4 Switch the Panel View terminal to Run mode The application file starts to run You can now transfer alarm history files over the selected network 3 14 Uploading 1000e 1200e 1400e Application Files and Alarm History Files To configure the PanelView e Trans
42. Support Services 0 cece eee eee P 4 Allen Bradley Support 000 c cece eee eee eee eee P 4 Local Product SUpport 2 0 2cc decidir ae eeiwt reintre P 4 Conventions Used in This Manual 00 cee ee eeee P 4 Chapter 1 About the PanelView e File Transfer Utility 32 0 1 1 Types of Applications 00 eect ene 1 3 Types of Transfers ses cna Ft acne oe keen See a eRe as 1 3 Methods of Downloading and Uploading Applications and Alarm History Files 24 002 2 02s08 ve eeeeasaneae ad wen eee 1 3 Fil Transter TIPS en 26 diros ceases RELEE seein es eed 1 4 G neral nescera erni den Arr neeaae tate eE Aa 1 4 For PanelView 1000e 1200e or 1400e Terminals Transfers 1 5 PanelView e Transfer Utility 32 and RSLinx 1 6 Chapter 2 System Requirements 40d iced iwdowede oeiee tees 2 1 PanelBuilder Applications 000c ee eee 2 2 PanelView Terminals 5 2ic0v0dsicuvi titers widivwcusve 2 2 Equipment Required for Transferring Applications 2 3 Serial Upload Download 2 cc ics cn ceca cea eee ceas ee es 2 3 DH Network Transfers 00 cece eee eee 2 4 ControlNet Network Transfers 0 00 cece eee eee 2 8 Remote I O Pass Through Transfers 00ee0 ue 2 12 General Installation Information 000 cc cece eens 2 16 Installing FTU32 from CD ROM on Windows NT or Windows 95 2 17 Installing the FTU from CD ROM on Windows 95 or W
43. The Transfer Application screen must also be displayed at the terminal Switch the PanelView terminal to Configure mode Select Transfer Application from the Terminal Configuration screen Then select the Serial tab For serial transfers The development computer s baud rate does not match the baud rate defined in the PanelView terminal Ensure the baud rate in the PanelView terminal matches the baud rate in the Transfer Utility To check the terminal s baud rate select Transfer Setup from the Terminal Configuration screen Then select the Serial tab For serial transfers The serial cable may be disconnected or the wrong cable is being used Ensure the serial cable is properly connected and try the file transfer again For network transfers The specified transfer path may not match the transfer path defined in the PanelView terminal s Transfer Setup screen Ensure the transfer path in the PanelView terminal matches the transfer path in the Transfer Utility To check the terminal s transfer path with an application selected select Terminal Network Setup from the Terminal Configuration screen To check the terminal s transfer path without an application selected select Transfer Setup from the Terminal Configuration screen Then select the Network tab For network transfers A network cable may be disconnected or the wrong cable is being used Ensure the network cable is properly connect
44. View e Transfer Utility 32 2 25 Browse the CD for file FTU_V3 Browse Disk 1 Run SETUP EXE If you are running on Windows 3 x choose Run from the File menu In the Run window command line type E FTU_V3 DISK1 SETUP EXE where E is the drive containing the PanelView 1200 1400e Transfer Utility disk and press Enter A window appears recommending you close all open Windows applications If you followed step 1 choose Next otherwise close all open Windows applications then choose Next The File Transfer Utility Installation Program runs automatically In the registration window enter registration information about your copy of the FTU Registration information is on the software registration card in your PanelBuilder 1400e or Panel View 1200 1400e Transfer Utility package Choose the drive and directory in which the FTU will be installed By default this is C AB PB1400E FTU To change the destination drive or directory type the new drive and or directory in the Program Files box Then choose Next Choose the program folder program group in which you want to install the FTU s icons which include a Readme file icon the Transfer Utility icon and an Uninstall icon By default the icons are installed in the PanelBuilder 1400e program folder Then choose Next Choose whether the installation utility will modify the AUTOEXEC BAT file The entry C RSI CMN is required in the PATH variable for the FTU to wo
45. a To select the network gt Specify DH ControlNet or Ethernet as the network to which your PC is connected To select the driver 1 Click the Refresh List button to refresh the list of drivers 2 Select a driver from the list of available drivers Senal 1 Senia 2 5 14 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Driver options include serial and RSLinx ports When selecting a driver Serial 1 and Serial 2 are available to communicate directly with the PanelView terminal serial port or with a 1770 KF2 KE or 1770 KFC without using RSLinx The other driver selections need RSLinx which can be installed on the computer being used Before the RSLinx driver appears in the driver list you must first configure the RSLinx driver and then refresh the list of available drivers To configure an RSLinx driver you must start RSLinx by clicking the Invoke RSLinx button To refresh the list of available drivers click the Refresh List button Note Serial 1 and Serial 2 drivers enable you to configure two different serial setups for example baud rates Also they can accommodate the two communication ports on many computers Refer to the physical communication ports on your computer to determine the correct port for your application Select the Configure Driver button If you have selected an RSLinx port choosing the Configure Driver button opens the RSLinx utility When you return to t
46. ain COM Port ControlNet Version 1 5 KFC card is not ControlNet Version 1 5 is currently not Transfer aborted recognized by WINtelligent LINX or supported Use ControlNet Version 1 25 INTERCHANGE until further notice Driver KFC to CNet Problem with ControlNet Version 1 5 KFC card is not ControlNet Version 1 5 is currently not communication Transfer aborted recognized by WINtelligent LINX or supported Use ControlNet Version 1 25 INTERCHANGE until further notice No application has been selected on the PanelView terminal Cannot upload You have not selected an application Select an application on the PanelView terminal before uploading Insufficient disk space for the uploaded application The host PC s hard drive does not have enough disk space Provide the host PC s hard drive with more disk space or select another hard drive Invalid name for the alarm history file that is being uploaded The alarm history file that is being uploaded does not have a valid name Specify the name for the alarm history file that is being uploaded This firmware version does not support the alarm history upload feature The current firmware does not support the alarm history upload feature Upgrade the firmware to Version 2 or later Unable to format the terminal storage An application is currently running on the PanelView terminal You are attempting to fo
47. alue Message delimited by a pair of double quotes Double quote character in the message text is translated to 2 double quotes For Version 02 00 00 and later applications the character sequence n backslash n in the message text is translated to n For Version 02 00 00 and later applications the newline character in the message text is translated to a backslash character followed by the letter n n Trigger Date Each field is separated by a forward slash 4 digit year 1980 to 2043 it month 1 to 12 it day 1 to 31 De 2 aaa Trigger Time m w io g field is separated by a colon it hour 0 to 23 it minute 0 to 59 it second 0 to 59 De 2 Q aaa Acknowledge Date Each field is separated by a forward slash If the alarm is not acknowledged no text follows the alarm event data 4 digit year 1980 to 2043 2 digit month 1 to 12 2 digit day 1 to 31 Acknowledge Time Each field is separated by a colon If the alarm is not acknowledged no text follows the alarm event data 2 digit hour 0 to 23 2 digit minute 0 to 59 2 digit second 0 to 59 Refer to the PanelBuilder 1400e Configuration Software for Windows User Manual for information about message formats and limits 3 10 Uploading 1000e 1200e 1400e Application Files and Alarm History Files Uploading the Alarm History Files To upload alarm history files you must complete these steps in orde
48. arity and error settings on the Transfer Setup screen correspond with the host computer settings You cannot perform a serial download Check that the COM port you are using is enabled by your Windows operating system This can be done by checking the Ports settings under Control Panel For more information refer to your Windows 3 1 Windows 95 or Windows NT user documentation Check if you are using the same COM port that your mouse is using Typically the mouse is plugged into COM 1 however it may be plugged into COM 2 Check the labelling on the rear of your computer to determine which port the mouse is hooked up to and which port your upload download cable is hooked up to Check if the COM port you are using is using the same IRQ number as another device in your system Possible causes of conflict are PCMCIA device cards Ethernet cards sound cards or other PC add on cards To determine the IRQ settings for your serial port refer to your computer s user documentation Check the settings for the port in the Control Panel and check that the settings match Then check the IRQ settings for the other devices listed above to ensure there is nota conflict If you have been using another software package to access the serial port such as a communications package A B 6200 software or even INTERCHANGE you may need to restart the computer To do this close the application using the serial port disconnect
49. artition 2 C 0 0 Storage not formatted Help 4 Determine the destination file name for the application file you are downloading by pressing the Download Options button or clicking 2 from the toolbar The File Transfer Options dialog box is displayed File Transfer Options x Download Options Upload Options 7 PE Configure runtime behaviour for download file transfers Before Download Starts I Prompt Download Destination Prompt user to enter a new destination filename in the P terminal During the Download I Overwrite Existing File Overwrite any existing files in the P terminal with the same name T Format If Full Format P terminal destination storage if full l Download If Newer Download only if source file is newer than the one in the PV terminal F Ignore Compatibility Wamimnags Ignore any terminal incompatibility and mismatch warnings during transfer After Download Completes V Make Application Current Make downloaded application the current one in PY terminal after transfer If you want the file to download with the same name as the selected download file then clear the Prompt Download Destination box If you want to enter a new name for the download file select Prompt Download Destination All DOS file naming restrictions apply Downloading 1000e 1200e 1400e Application Files 4 9 5 Select or clear the following download options Download Option De
50. ated in PanelBuilder 1400e for Windows Files are initially created and edited as pvc You then must save the file as a pvd to download it These are Panel View enhanced 1200 Series F and later and 1000e 1200e 1400e terminal files The Panel View e Transfer Utility 32 does the following types of transfers downloading an application file Transferring an application file from the development computer to a Panel View terminal so the application can be run PanelView enhanced 1200 Series F and later and Panel View 1000e 1200e 1400e applications can be downloaded uploading an application file Transferring an application file from the PanelView terminal to the development computer that the Panel View e Transfer Utility 32 is on so the application can be edited or archived Panel View enhanced 1200 Series F and later and PanelView 1000e 1200e 1400e applications can be uploaded uploading alarm history files Transferring the Alarm History File from the Panel View terminal to the development computer so the files can be analyzed or archived Only Panel View enhanced 1200 Series F and later and 1000e 1200e 1400e V02 00 00 and later Alarm History files can be uploaded There are three methods for downloading and uploading applications and alarm history files Serial RS 232 Upload Download To transfer applications serially you need an RS 232 Serial Upload Download cable A B Cat no 2706 NC 13 2711 NC13 or 2711 NC14 fo
51. can also use this utility to upload alarm history information from a PanelView 1000e 1200e 1400e terminal to the computer that the Transfer Utility runs on Only Version 2 and later alarm history files can be uploaded To start the PanelView e Transfer Utility 32 double click the following icon in Windows NT or Windows 95 Bs Panety ie e Trangler Litility 32 After you start the application the following splash screen is displayed momentarily PanelView e Transfer Utility 32 peralies uneka lainey 1 2 Introducing the PanelView e Transfer Utility 32 When the splash screen disappears the following main download upload dialog box is displayed The PanelView e Transfer Utility 32 can also be accessed from the PanelBuilder 1400e software In the main PanelBuilder 1400e dialog box choose Download or Upload from the File menu The Transfer Utility s main download upload dialog box is displayed automatically pe Note PanelBuilder software does not need to be installed in order to do file transfers You need only PanelView e Transfer Utility 32 and a PanelView application file saved in a pvd format Types of Applications Types of Transfers Methods of Downloading and Uploading Applications and Alarm History Files Introducing the PanelView e Transfer Utility 32 1 3 You can transfer terminal application files whose names end in pvd using the Panel View e Transfer Utility 32 The pvd files are cre
52. communication device and settings Refer to the INTERCHANGE Device Configuration Utility user documentation for information on using the utility FTU Version 3 Introducing the PanelView e Transfer Utility 32 1 7 If your version of INTERCHANGE is earlier than 6 1 0 you must view and configure the ports outside of the Panel View 1200 1400e Transfer Utility Refer to your INTERCHANGE user documentation Again make sure the port you select is configured correctly for your communication device and settings PanelView 1200 1400e Transfer Utility and WINtelligent LINX The Panel View 1200 1400e Transfer Utility Version 3 supports WINtelligent LINX network drivers Version 5 20 00 or later The PanelView 1200 1400e Transfer Utility supports a subset of the WINtelligent LINX drivers those used for appropriate DH ControlNet and serial transfers You can use these drivers to transfer files over DH ControlNet RIO Pass Through or serial connection networks Contact your Allen Bradley Sales Representative for more information on WINtelligent LINX To use the WINtelligent LINX drivers install them before setting up transfer communications The PanelView 1200 1400e Transfer Utility displays the WINtelligent LINX drivers as driver options but you can use them only if they are installed Make sure the driver you select is configured correctly for the communication device and settings You can open the WINtelligent LINX configuration utility from
53. cribes how to start the program from Windows NT or Windows 95 and how to start the program from PanelBuilder 1400e To start the FTU32 from Windows NT or Windows 95 1 Click the Start button on the taskbar 2 Choose Programs then choose PanelBuilder 1400e or the folder you specified when you installed the program 3 Choose PanelView e Transfer Utility 32 The following dialog box is displayed Ele Trerhted Bassai Tyke ie 1 piei ga aja Upper eet aera etre ees 1 PEPENE e n E a epean a a ee og a ie ee ee itn irma Working with the PanelView e Transfer Utility 32 2 27 If you have problems running the Transfer Utility and you have had previous versions of the Transfer Utility on your computer we recommend you select Uninstall Panel View e Transfer Utility 32 in the PanelBuilder 1400e folder The Uninstall Panel View e Transfer Utility 32 program deletes any of the shared files and windows system file conflicts that may exist from earlier installations You will then have to reinstall the Transfer Utility software If problems still exist contact Allen Bradley Technical Support For information about obtaining Technical Support see the Preface in this manual Publication 2711E UM003B EN P 2 28 Working with the PanelView e Transfer Utility 32 To start the FTU32 from PanelBuilder 1400e p gt Inthe PanelBuilder 1400e main dialog box choose Download or Upload from the File menu
54. d continue 9 The setup utility shows a summary of the choices you made in the preceding dialog boxes To make any changes choose the Back button Otherwise choose Next to begin the installation 10 After all the applications have completed installing you are prompted to reboot your computer You can reboot immediately or later but you must reboot before you can run the Transfer Utility or other applications successfully If you want to upload or download PanelView files over the PLC networks after you finish installing the Transfer Utility you also need to install RSLinx Lite software Version 2 0 or later See the RSLinx user documentation provided for installation procedures Do not cancel the installation while it is in progress If you want to undo the installation let the installation finish then use Uninstall Panel View e Transfer Utility to remove all the installed files and to update the registration Panel View 1200 1400e Transfer Utility FTU Version 3 is provided in the Panel View 1200 1400e Transfer Utility kit 2711E ND7 on CD You can create your own 3 5 inch floppy disks from the CD For instructions on how to create floppy disks of the software from the CD refer to the Floppies txt file in the root directory of the CD To install the FTU 1 Start Windows 95 or Windows 3 x If you re already in Windows close all open Windows applications 2 Insert the CD in the drive 10 Working with the Panel
55. e DH networks can be bridged by a 1785 KA interface module or by a Pyramid Integrator that has an RM or KA module A 2 DH Networks Bridged by a 1785 KA Constructing the Transfer Path The format of the transfer path on remote DH networks is Transfer Path Format Valid Entries ll rrr ss I local KA address 0 77 octal rrr remote KA address 0 376 octal ss PanelView address on remote DH 0 77 octal or You can shorten the offlink address by combining the remote KA address and remote transfer path into one three digit number The system reads only the first digit of the remote KA address and adds the two digit remote PanelView address to produce a shorter address ll rss I local bridge address 0 77 octal rss combined remote KA address and remote PanelView 0 376 octal address The following figure shows a development computer connected to a DH network The local DH network is bridged to a remote DH network which is bridged to a second remote DH network The 1785 KA interface modules are used to bridge the networks Constructing the Transfer Path A 3 The valid transfer paths for the various PanelView terminals in the figure are PanelView Address Valid Transfer Path 21 7 310 21 or 7 321 Figure A 1 DH Network Bridged by a KA Interface Module Remote DH 21 PanelView 1400e Terminal Remote DH Local DH 10 Development Computer A 4 Constructing the Transfer Path
56. e changes and continue The setup utility shows a summary of the choices you made in the preceding dialog boxes To make any changes choose the Back button Otherwise choose Next to begin the installation After all the applications have completed installing you are prompted to reboot your computer You can reboot immediately or later but you must reboot before you can run the Transfer Utility or other applications successfully If you want to upload or download Panel View files over the PLC networks you also need to install RSLinx Lite software Version 2 0 or later See the RSLinx user documentation provided for installation procedures Do not cancel the installation while it is in progress If you want to undo the installation let the installation finish then use Uninstall Panel View e Transfer Utility to remove all the installed files and to update the Windows registry Installing the FTU from PanelBuilder 1400e CD ROM on Windows 95 or Windows 3 x Working with the PanelView e Transfer Utility 32 2 21 Panel View 1200 1400e Transfer Utility FTU Version 3 is provided on the PanelBuilder 1400e CD ROM The software installation program creates a directory on your hard drive for the FTU and copies all necessary files to it By default the drive and directory is C AB PB1400E FTU You can change this default You can create your own 3 5 inch floppy disks from the CD For instructions on how to create floppy disks of the softwa
57. e is displayed if the application you are downloading to the PanelView terminal is incompatible with the terminal s type or its firmware version If this box is checked the warning message is not displayed By default this box is unchecked and a warning message is displayed Note Although an incompatible file can be downloaded it cannot be selected as the current application If the Make Application Current box is selected the Ignore Compatibility Warnings option is not available Make Application Current This box is selected by default When selected the newly downloaded application will become the currently active application When the terminal is switched to Run mode the current application is executed Clear this check box if you don t want the downloaded file to be selected automatically as the current application Note The application file is automatically selected after a successful download if there is no current application in the terminal whether this option is enabled or not 4 10 Downloading 1000e 1200e 1400e Application Files 6 Click OK to save the settings and exit from the File Transfer Options dialog box 7 Configure communications settings for the transfer following instructions in Chapter 5 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 8 To save the settings in the Download main dialog box choose System Options from the Options menu or Be from the to
58. ecting the Transfer Method Configuring the Transfer Parameters To select the transfer method p gt Inthe main download upload dialog box select the download upload transfer method Pii Mpe dey Hir H mm ped jl Trma Hin aa E pme r aan a imiy bee paren r berama Taunt eed T jj Daign Heie Parnim 1 arp ml es a ema og aii rere ore aai eirin You can configure the transfer parameters using either of the following methods e obtain transfer parameter values from an application file e manually select the transfer parameter values Obtain Transfer Parameters from an Application File An application file is a pvd file that runs on a PanelView terminal It is also called a runtime PV file When selected all the transfer parameter values from the pvd file are placed in the appropriate transfer parameters in the Configure Transfer Method dialog box For ControlLogix bridging you cannot obtain transfer parameter values from an application file Configuring Communications Settings for 1000e 1200e 1400e Application Transfers To obtain transfer parameter values using an application file 1 Choose Get Transfer Parameters From in the Parameters menu or choose Bis from the toolbar The Runtime PV File tab in the Get Transfer Parameters From dialog box is displayed Fanina Fes Fila Spenty the sudny Pane view perme Bebo wiih commuraton Paes ae ibe sree Ceo _ oe 2 Enter the name of the
59. ed and try the file transfer again For network transfers The wrong development computer network driver may be used or incorrectly configured Ensure the correct network driver is used and use the communication software to configure the network driver For network transfers The terminal is incorrectly in the Configure mode it must be in Run mode Switch the P anelView terminal to Run mode For Remote I O Pass Through transfers The configured Pass Through control byte does not match the control byte setting in the P anelview terminal Ensure the control byte in the PanelView terminal matches the control byte in the Transfer Utility To check the terminal s control byte with an application selected select Terminal Network Setup from the Terminal Configuration screen To check the terminal s control byte without an application selected select Transfer Setup from the Terminal Configuration screen Select the Network tab and then press the Block Transfer Files button For Remote I O Pass Through transfers A network cable may be disconnected or the wrong cable is being used Ensure the network cable is properly connected and try the file transfer again Problem Troubleshooting for the PanelView e Transfer Utility 32 Cause What to do Host PC failed to communicate with PanelView terminal Error code RDM number 0x X Error 4209 continued For Remote I O Pass Through transfer
60. ed by the Panel View terminal Do not interrupt a download by cycling power during the operation Introducing the PanelView e Transfer Utility 32 1 5 e Do not try to download application files from two development computers to the same location at the same time Results are unpredictable e During the download the PanelView terminal ignores all operator inputs and PLC outputs The current application screen is removed and the Transfer screen and progress bar are displayed e The rack assignments for Remote I O applications or terminal network address for DH and ControlNet remain as they were set for the previous current application until the download is complete For PanelView 1000e 1200e or 1400e Terminals Transfers e Before you download to PanelView 1000e 1200e or 1400e terminals check the size of the application file the pvd file to ensure it will fit in the terminal s memory or on the PCMCIA memory card For more information refer to Chapter 3 Working with Applications in the PanelBuilder 1400e Configuration Software for Windows User Manual Publication Number 2711E 819 e When you upload an application from the PanelView 1000e 1200e or 1400e terminals using the PanelView e Transfer Utility 32 the initial tag values of the application are uploaded not the application s current values e When you upload an application from the PanelView 1000e 1200e or 1400e terminals to edit it in PanelBuilder many of
61. elopment Computer Hill 1784 KT Logix55XX ControlNet DH RIO Power Supply Ethernet PanelView 1400e Allen Bradley ControlNet 7 Connection 1784 CP Cable DH 25040 Publication 2711E UM003B EN P 2 8 Working with the PanelView e Transfer Utility 32 Publication 2711E UM003B EN P ControlNet Network Transfers The 1200e terminals are not compatible with ControlNet You need the following Allen Bradley ControlNet Interface modules installed in the development computer to transfer applications over ControlNet 1784 KTCX Series B or later e 1784 KTC e 1770 KFC You can transfer applications over a ControlNet network using RSLinx drivers or Serial 1 or Serial 2 drivers if the transfer is over a KFC module To download over a ControlNet network the Panel View terminal must be active on the same network as the development computer File transfers over one ControlLogix bridge can be supported You can transfer files from the development computer over a DH ControlNet or Ethernet network to a ControlLogix gateway module and then bridged to the Panel View terminal over a DH or ControlNet network ControlLogix gateway modules are 1756 DH RIO 1756 CNB and 1756 ENET Working with the PanelView e Transfer Utility 32 2 9 Figure 2 5 ControlNet Network Download with 1770 KFC Development Computer
62. etwork Type F1 Important After a successful download of an application file over DH or ControlNet the terminal automatically resets the Address Source to Application uses the application file parameters and discards the Manual Address parameters 5 Make changes to the transfer parameters For DH transfer setups you can change both the baud rate and the terminal network address For ControlNet transfer setups you can change the terminal network address not the baud rate 6 Choose OK The Current Application is deselected Downloading 1000e 1200e 1400e Application Files 4 5 7 Switch the Panel View terminal to Run mode The Application Transfer screen is displayed You can now transfer application files over the network Application Transfer Ready for Transfer Resume Run Mode F21 Return to Config Mode FIZ To prepare the PanelView terminal for a Remote I O Pass Through download 1 To use the Current Application s transfer parameters make sure the Panel View terminal is in Run mode to start running the application and then follow the next procedure to configure the Panel View e Transfer Utility 32 for a download A Current Application is a file that is currently selected and running on the Panel View terminal To view the Current Application s transfer parameters switch the Panel View terminal to Configure mode At the Panel View terminal choose the Terminal Network Setup button
63. fer Method Driver Configuration Network Transfer Method Network and Driver Configuration 00 eee eee eee eee Remote I O Pass Through Network Driver and Pass Through Setup Configuration Saving the Communication Settings 0 eee eee Chapter 6 General Upload Download Problems 00000 Communication Errors s s cess es aeesee aaa dada cae dnss pvd File Errors ve cicecdus vin shee SE deend be we eta ends Compatibility Errors 3c ccleucbeied ohh eteredtceteceduass Driver EMMONS ais ace Stand ashen a a atin watloe Mia E ants Appendix A ControlNet Addressing ei weet a cde neds kbs e bee eee eea wees DH Addressing i ao eibanaec eae aaheenae nagres maseenen DH Networks Bridged by a1785 KA 000 aa Multiple DH Networks Connected by a Pyramid Integrator Pl Index Before You Begin Purpose of This Manual Preface Preface Welcome to the Allen Bradley Panel View e Transfer Utility 32 With this software you can transfer PanelBuilder applications to and from an IBM compatible personal computer and Panel View 1000e and 1400e operator terminals This utility is referred to as FTU 32 in this manual and supports RSLinx drivers There are references to FTU ver 3 in this manual which is a 16 bit PV e upload download program designed to be used on computers with Windows 3 1 or Windows 95 operating systems along with Interc
64. fer Utility 32 for the upload 1 In the PanelView e Transfer Utility 32 choose the Upload tab from the main dialog box H PanelView e Transfer Utility 32 2 In the Path box type the name of the directory to which the uploaded application file will be saved or choose Browse to find a directory 3 In the Data to Upload box select Alarm History 4 Determine the destination file name for the alarm history file you are uploading by pressing the Upload Options button or clicking from the toolbar The File Transfer Options dialog box is displayed File Transfer Options Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 15 If you want the file to upload with the same name as the selected upload file then clear the Prompt Upload Destination box If you want to enter a new name for the uploaded file select Prompt Upload Destination Windows NT or Windows 95 file naming restrictions apply The file name can exceed 8 characters but the Panel View firmware truncates file names that exceed 8 characters 5 Select or clear the following upload options Upload Option Description Clear Alarm History after Upload This option allows you to clear alarms in the alarm history after an alarm history upload If selected only those alarms triggered before the upload are cleared Alarms triggered after the upload is initiated are not cleared Clear the check box if you do not wan
65. fer path using one of the following methods e enter the transfer path manually e use Station Browse to start RSWho use the transfer path value from a runtime PV file To set the transfer path manually p gt If you know the transfer path enter it in the Transfer Path box See Appendix A for transfer path formats You cannot enter a transfer path manually for file transfers over ControlLogix Gateway bridging To set the transfer path using Station Browse 1 Click Station Browse to start RSWho 2 Highlight the device name 3 Click OK The transfer path you selected in RSWho is displayed in the Transfer Path box in the Configure Transfer Method dialog box To set the transfer path using Runtime PV File gt See Obtain Transfer Parameters from an Application File in this chapter for details Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 5 13 Remote I O Pass Through Network Driver and Pass Through Setup Configuration When you select Remote I O Pass Through as the transfer method Network Accessed Driver and Pass Through Setup Device Type Transfer Path Rack Word and Byte are the options you can configure cal Hietesark Fesili LO Pucis T hough berma 1A0 Pace Tihemagh Trangher Ceacripton Transfer dats babesen pour PE nd qt pee ae Tie Pse Thapagh dyare mut cupped s Fi connection Paraben rang Pe E Telti a Heban Duis Herk deramat Cerna a Seal i Saaz to
66. hange or WinLinx drivers FTU ver 3 is included on the CD with both PanelBuilder 1400e 2711E ND1 and the separate upload download utility package 2711E ND7 In addition the PV 1200 DOS upload download utility is also included with catalog number 2711E ND7 to support the original 12 CRT based PanelView 1200 This can be installed on the same computer and accessed from FTU ver 3 above See publication 2711 UM010B EN P PanelBuilder 1200 Transfer Utility manual for additional information Note In all cases the associated PanelBuilder software must be used to save the file in downloadable format pvd for PV e and cfg for PV 1200 before the download utility is used Before you begin you should be familiar with e Microsoft Windows 2000 Microsoft Windows NT 4 0 Microsoft Windows 95 or Microsoft Windows 3 x operating system The PanelView e Transfer Utility User Manual describes the methods of transferring application and alarm history files between the computer and the Panel View terminal The computer must have the Panel View e Transfer Utility installed This user manual also provides step by step instructions for each method P 2 Preface Contents of This Manual Chapter Title Contents Preface An overview of this manual and a list of related publications 1 Introducing the Introduces the PanelView e Transfer Utility 32 PanelView e Transfer and the methods of transferring P anelB
67. he Transfer Utility choose the Refresh List button to refresh the list of drivers Refer to the RSLinx user documentation for information on using the utility If you have selected Serial 1 or Serial 2 the Communication Driver Configuration dialog box appears Goinminboniion Driver Caigua i Creer Bena i zue M Paiky Ems Fod com Hane E gic i T Even r CAC Coca a Define the settings in the Communication Driver Configuration dialog box as follows Baud Specify the data transfer rate between your computer and the 1770 KF2 KE or 1770 KFC This must match the baud rate configured for the Panel View terminal The default setting is 9600 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 5 15 Port Specify COM1 COM2 COMS3 or COM4 as the serial port used to connect the serial cable to the 1770 KF2 KE or 1770 KEFC The default setting is COM1 Parity Specify None or Even for the type of error checking to be used This must match the parity configured for the 1770 KF2 KE or 1770 KFC The default setting is None Error Specify the error detection protocol used by the device BCC is Block Check Character and CRC is Cyclic Redundancy Check This must match the error checking protocol configured for the 1770 KF2 KE or 1770 KFC The default setting is BCC To set the device type p Select a device type from the list The device type is the PLC to which the Panel View term
68. he PanelView terminal and the host PC The PanelView terminal is not in transfer State Set the PanelView terminal to a transfer State General Download and Upload Error Messages Consult the following table to identify and respond to some common error messages that can appear on the screen when you upload or download data or upload alarm history Messages General Types of Messages Cause What to do File path name error messages for either source file or destination file Either no file name was entered or an incorrect file name was entered Be sure you ve entered a valid source or destination file name in the File and Path fields Must have a valid 8 character DOS file name a valid DOS path and a valid extension none pvd to upload download applications or csv to upload alarm history The download as file name must also satisfy the above conditions Selected source file cannot be accessed Check that the source file path name is correct or that it exists Destination file already exists Do you want to overwrite it Informational or prompt message Select Yes to overwrite the destination file Select No to abort the upload download Destination file cannot be created Probably a problem with the PCMCIA card or flash memory Reformat the card or try another card If there is still a problem contact your A B Sales Representative Incompatibility messages
69. ial tab Wrong baud rate Check that the baud rate parity and error Settings on the Transfer Setup screen correspond with the host computer settings FTU32 Ver 5 Communication Errors Problem Troubleshooting for the PanelView e Transfer Utility 32 6 3 Cause Use the following table to identify communication problems you may encounter What to do Cannot start any transfer command Channel is The PanelView terminal may currently be Wait for the PanelView terminal to complete busy busy its current process and try again Error 2103 File was not found The specified download application file Ensure the specified download application Error 2112 cannot be read file exists and is not corrupted Could not create specified upload file Error 2113 The specified upload application file cannot be written Ensure the directory exists and there is enough disk space No current application file exists Error 2114 There is no current application selected in the PanelView terminal Ensure a current application is selected in the terminal Could not read data from download file Error 2115 The specified download application file cannot be read Ensure the specified download application file exists and is not corrupted It is now too late to abort the file transfer Warning 2117 All packets are sent you cannot cancel the file transfer at this point If yo
70. igher microprocessor with a recommended minimum of 16 MB RAM for Windows 95 operating system or 32 MB RAM for Windows 2000 SP2 NT operating system CD ROM drive recommended A hard disk with 10 MB of free space and 15 MB for RS Linx Lite An 8 MB swap file A 3 5 inch high density 1 44 MB disk drive An RS 232 serial port for uploading or downloading applications or other communication cards listed later in this chapter A standard VGA 640 by 480 display adapter configured for at least 16 colors A mouse or pointing device supported by Windows S oftware Microsoft Windows 2000 SP2 Windows NT Version 4 0 or Windows 95 Publication 2711E UM003B EN P 2 2 Working with the PanelView e Transfer Utility 32 Catalog Number PanelBuilder Applications For details about PanelBuilder applications see Types of Applications in Chapter 1 of this manual PanelView Terminals To transfer files using the Panel View e Transfer Utility 32 you must have one or more of the following Panel View terminals Table 2 B lists the terminal products and their catalog numbers Table 2 B PanelView Terminal Products and Catalog Numbers Product Description 2711E T10C6 1000e Touch Screen Terminal Color display clip mount NEMA 4X 2711E K10C6 1000e Keypad Termina Color display clip mount NEMA 4X 2711E T10C15 1000e Touch Screen Terminal ControlNet 1 5 enhanced 2711E T10C6 terminal 27
71. in the Terminal Configuration screen to display the Terminal Network Setup screen Exit the screen after you finish viewing the transfer parameters Go to step 6 To download with transfer parameters different from those of the Current Application or if you don t have a Current Application selected switch the PanelView terminal to Configure mode At the Panel View terminal choose the Transfer Setup button Go to step 2 2 Select the Network tab 4 6 Downloading 1000e 1200e 1400e Application Files 3 Choose RIO Pass Through as the Address Source When you choose RIO Pass Through the configuration parameters for the currently selected application file are disabled Transfer Setup Serial Network F17 F18 l Application RIO Pass Through Network Direct Network Setup Rack Definition PLC 5 80 230 4K Device Baud Rack Numi Type Rate F1 F2 Control Byte Module Groups ber EE E T e 6 7 F8 Last Chassis FS 4 Make changes to the transfer parameters For Remote I O Pass Through applications you can change the baud rate device type and the control byte 5 Choose OK The Current Application is deselected 6 Switch the PanelView terminal to Run mode The Application Transfer screen is displayed You can now transfer application files over the network Application Transfer Ready for Transfer Resume Run Mode F21 Return to Config Mode FIF Downloading
72. inal is connected over Remote I O For DH Remote I O Pass Through the default device is PLC 5 11 Integral For ControlNet Remote Pass Through the default device is PLC 5 20 For Ethernet Remote Pass Through the default device is PLC 5 20 To set the transfer path Set the transfer path using one of the following methods enter the transfer path manually e use Station Browse to start RSWho use the transfer path value from a runtime PV file To set the transfer path manually p If you know the transfer path enter it in the Transfer Path box See Appendix A for transfer path formats You cannot enter a transfer path manually for file transfers over ControlLogix Gateway bridging To set the transfer path using Station Browse 1 Click Station Browse to start RS Who 2 Highlight the device name 3 Click OK The transfer path you selected in RSWho is displayed in the Transfer Path box in the Configure Transfer Method dialog box 5 16 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Saving the Communication Settings To set the transfer path using Runtime PV File gt See Obtain Transfer Parameters from Application File in this chapter for details To configure Pass Through Byte Definition parameters p gt Specify Pass Through settings as follows Rack Select the rack number that contains the Pass Through control byte Your selection should match the rack number configured i
73. indows 3 x 2 21 Installing the FTU32 from Floppy Disks on Windows NT OF WINGGWS 95 c2cccatuud cen suaeeens aha eae ets eas 2 23 Installing the FTU from Floppy Disks on Windows 95 OF WINGGWS OX tein tecesiad aterea tabe ne eels 2 24 Starting the PanelView e Transfer Utility 32 Version 5 FTU32 2 26 Exiting the PanelView e Transfer Utility 32 05 2 28 Publication 2711E 6 16 toc ii Table of Contents Uploading 1000e 1200e 1400e Application Files and Alarm History Files Downloading 1000e 1200e 1400e Application Files Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Troubleshooting for the PanelView e Transfer Utility 32 Constructing the Transfer Path Publication 2711E 6 16 Chapter 3 Uploading PanelView 1000e 1200e 1400e Application Files Uploading the PanelView 1000e 1200e 1400e Alarm History File Alarm History Information 00 0 0 cee eee eee ee Uploading the Alarm History Files 0 00000 ee Chapter 4 Downloading PanelView 1000e 1200e 1400e Application Files Chapter 5 Selecting Communication Hardware and Driver Packages Configuring Communications 0 0 eee Selecting the Transfer Method 0 cece eee ees Configuring the Transfer Parameters 0 00 ee uee Obtain Transfer Parameters from an Application File Configure Transfer Parameters Manually Serial Trans
74. indows 95 or Windows NT Version 5 supports Panel View application file transfers over networks using RSLinx software drivers Version 5 for the Windows 95 operating system is recommended If you are installing on Windows NT 2000 the Select Version dialog box does not appear Version 5 is automatically selected In the PanelBuilder Installation dialog box choose either to install products or to view online manuals Then choose Next Panel iakisi Init alai If you select View Online Manuals Adobe Acrobat is automatically started and you can view the manuals from the CD ROM In Adobe Acrobat you can select which online manual you want to display If you select Install Products the Choose Applications dialog box is displayed Working with the PanelView e Transfer Utility 32 2 19 6 In the Choose Applications dialog box choose to install the 10 Transfer Utility You can choose to install more than one application Then choose Next Chose the moicaora t priat MPR D Turia Lit D Geis Fresas pge D Ori Hiri me u l a In the registration window enter your user name company name and serial number You can obtain registration information from the software registration card that is in your PanelBuilder 1400e package A B Catalog Number 2711E ND1 or Transfer Utility package A B Catalog Number 2711E ND7 Choose Next In the confirmation window verify the user information you have entered Select Yes t
75. ing with the PanelView e Transfer Utility 32 2 13 Figure 2 8 Remote I O Pass Through on a DH Network Development Computer EANNAN TAMU PanelView 1400e 1784 CP RIO 25044 Publication 2711E UM003B EN P 2 14 Working with the PanelView e Transfer Utility 32 Figure 2 9 Remote I O Pass Through on a ControlNet Network with 1770 KFC Development Computer E TAMIAMI a 1770 KFC 1786 TPS PanelView 1400e PLC 5C or PLC 5C15 rO Coo 0000 ae E oo 3 ee ead mg D Y Publication 2711E UM003B EN P Working with the PanelView e Transfer Utility 32 2 15 Figure 2 10 Ethernet Remote I O Pass Through Development Computer PLC 5E or 1785 ENet sidecar ISA ethernet card G il oom 10 BASET HUB or Ethernet Link Dd A Patch Panel PanelView 1400e Touch Screen Terminal Remote I O 25046 Publication 2711E UM003B EN P 2 16 Working with the PanelView e Transfer Utility 32 General Installation Information Publication 2711E UM003B EN P You can install the PanelView e Transfer Utility 32 software using the CD ROM provided in the PanelBuilder 1400e software kit A B Catalog Number 2711E ND1 or using the CD provided in the Transfer Utility
76. is manual To start FTU from Windows 95 1 Click the Start button from the taskbar 2 Choose Programs and choose PanelBuilder 1400e or the folder you specified when you installed the program 3 Choose PanelView 1200 1400e Transfer Utility The following dialog box is displayed Panelview P00 1400 Tranaler Utility Be Publication 2711E UM003B EN P 2 30 Working with the PanelView e Transfer Utility 32 If you have problems running the File Transfer Utility and you have had previous versions of the File Transfer Utility on your computer we recommend you select Uninstall Transfer Utility in the PanelBuilder 1400e folder The Uninstall Transfer Utility program deletes any of the shared files and windows system file conflicts that may exist from earlier installations You will then have to reinstall the File Transfer Utility software again If problems still exist contact Allen Bradley Technical Support For Technical Support information see the Preface in this manual Starting the PanelView The procedure to start the Panel View 1200 Transfer Utility is the 1200 Transfer Utility same for Windows 95 and Windows 3 x This utility available in FTU Version 3 and earlier is used to transfer an application created in PanelBuilder Development Software for DOS or PanelBuilder 1200 Configuration Software for Windows Refer to the PanelView 1200 Transfer Utility User Manual Publication Number Transfer 2711 UM010B EN P f
77. iver you select is configured correctly for the communication device and settings You can open the RSLinx configuration utility from the Transfer Utility to configure the selected driver PanelView 1200 1400e Transfer Utility and INTERCHANGE The PanelView 1200 1400e Transfer Utility Version 3 supports the full range of INTERCHANGE serial and network drivers The INTERCHANGE drivers allow ports and communication devices to be shared between PanelBuilder and other Allen Bradley products such as the 6200 series PLC 5 Programming Software and PanelBuilder 900 INTERCHANGE drivers also support communication cards such as the KT and PCMK for DH communication Contact your Allen Bradley representative for more information on INTERCHANGE To use the INTERCHANGE drivers install INTERCHANGE before setting up file transfer communications The transfer utility displays the INTERCHANGE drivers as driver options but you can use them only if INTERCHANGE is installed The driver options INTERCHANGE Port 1 to INTERCHANGE Port 8 map to the eight ports supported by INTERCHANGE If you have INTERCHANGE Version 6 1 0 or later you can select one of these options and call up the INTERCHANGE Device Configuration Utility from the Panel View 1200 1400e Transfer Utility From the configuration utility you can view and change the configuration of any of the eight INTERCHANGE ports Make sure the port you select for your driver is configured correctly for the
78. l Network Remote I O Pass Through or Application from the drop down list box Typically the communication hardware in your computer determines your transfer method options To identify transfer method options for your computer host hardware refer to Table 5 A Table of PC Host Hardware and Applicable Drivers The Serial option is used when you perform a transfer using the COM port on your PC and the serial port on a Panel View terminal The Network option performs a transfer over DH or ControlNet The Remote I O Pass Through option performs transfers over DH ControlNet or Ethernet between the PC and PLC and over Remote I O from the PLC to the Panel View terminal The Application option available for downloads only allows the Transfer Utility to use the transfer parameters from the application file The application file to be downloaded is specified in the Source File box 2 If you selected Application click Start Download If you selected Serial Network or Remote I O Pass Through choose the Configure Method button select Configure from the Transfer Method menu or choose Th from the toolbar The Configure Transfer Method dialog box is displayed The system automatically takes you to the tab that corresponds with the transfer method you selected in step 1 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Serial Transfer Method Driver Configuration When you select Serial
79. n your application file or in the PanelView terminal The default rack is 3 Word Select the word in the rack that will contain the Pass Through control byte Your selection should match the word configured in your application file or in the Panel View terminal The default word is 0 Byte Specify the High or Low byte of the word that will be used as the Pass Through control byte Your selection should match the byte configured in your application file or in the Panel View terminal The default byte is Low For details about Panel View terminal transfer configuration settings see Transferring Application Files in Chapter 5 Configuring Panel View Terminals in your PanelView 1000e 1200e and 1400e Operator Terminals User Manual Publication Number 2711E 6 17 To save the communication settings for the current session choose Apply in the Configure Transfer Method dialog box To save the communications settings for the current session and exit from the Configure Transfer Method dialog box choose OK To exit without saving the settings choose Cancel To save the settings permanently choose System Options from the Options menu or from the toolbar In the General tab of the System Options dialog box select Auto Save All Settings to automatically save all settings when you exit You only need to select this check box option once because your selection becomes the application default If Auto Save All Settings is n
80. nfigure the PanelView e Transfer Utility 32 for the upload 1 In the PanelView e Transfer Utility 32 choose the Upload tab from the main dialog box A PanelView e Transfer Utility 32 gleis ge aL 2 In the Path box type the name of the directory to which the uploaded application file will be saved or choose Browse to find a directory 3 In the Data to Upload box select Application file 4 Determine the destination file name for the application file you are uploading by pressing the Upload Options button or clicking from the toolbar The File Transfer Options dialog box is displayed File Transfer Options Ignore Gear Confirmation Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 7 If you want the file to upload with the same name as the selected upload file then clear the Prompt Upload Destination box If you want to enter a new name for the uploaded file select Prompt Upload Destination Windows NT or Windows 95 file naming restrictions apply The file name can exceed 8 characters but the Panel View firmware truncates file names that exceed 8 characters 5 Click OK to save your settings and exit from the File Transfer Options dialog box 6 Configure communications settings for the transfer following instructions in Chapter 5 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 7 To save your settings choose System Options f
81. nstalled in the PanelView terminal Choose Yes to continue Choose No to cancel the file transfer The application will not be selected The KTCs driver cannot be used with a KTCs card and the KTCs driver cannot be used with a KTCx card The download application cannot be made current when download completes Do you want to continue The driver and the card do not match The KTCx driver requires the KTCx card and the KTCs driver requires the KTCs card Choose Yes to continue Choose No to cancel the file transfer The application will not be selected Warning 4215 The application to be downloaded The download application is not newer than Choose Yes to continue Choose No to s S the one currently running in the PanelView cancel the file transfer is not newer than the current application in the terminal S S Do you want to continue Warning 4221 terminal PanelView terminal has an earlier version s than the download application s s targeted version s and up The application cannot be made current after download Do you want to continue Warning 4222 The PanelView terminal is running an earlier firmware version that does not support the download application s targeted firmware version Choose Yes to continue Choose No to cancel the file transfer The application will not be selected The application s network type s is not supported for this version s s PanelView te
82. nsure the PanelView terminal is in Configure mode then press the Transfer Application button on the Terminal Configuration screen The PanelView terminal is not in Run mode when you attempt a network file transfer Put PanelView in Run mode The computer s serial port does not work Ensure the serial port is working by testing it with another device such as a printer Possible corrupt application file Try backup file or demo file download and upload Some other device may be using the serial port Check your hardware connections and reconfigure the serial port Pass through configuration is not properly Set up For more information about configuring pass through application file transfers see Chapter 5 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers in this manual You have not selected Transfer Application from the PanelView terminal s Configuration menu Choose Transfer Application from the Configuration menu Faulty network connection Check the network connection in PanelBuilder and or to the PanelView terminal Check the communication drivers setup Unable to communicate with terminal During a serial upload download the PanelView terminal is not in the Transfer Application screen Check that you are in configure mode On the PanelView terminal check that you are in the Transfer Application screen and you have selected the Ser
83. o proceed or No to edit the user information The Welcome dialog box for the Transfer Utility recommends that you close all open Windows applications If you have done that choose Next If you have chosen to install more than one application the first selected application begins installing automatically Choose the drive and directory in which the FTU32 will be installed By default this is C AB PB1400E FTU32 To change the destination drive or directory type the new drive and or directory in the Program Files box Or click the Browse button to select an installation directory Then choose Next Publication 2711E UM003B EN P 2 20 Working with the PanelView e Transfer Utility 32 Publication 2711E UM003B EN P 11 12 13 14 Choose the program folder program group in which you want to install the FTU32 s icons which includes a Readme file icon the Transfer Utility icon and an Uninstall icon By default the icons are installed in the PanelBuilder 1400e program folder Then choose Next Choose whether the installation utility will modify the AUTOEXEC BAT file If you are installing on Windows 95 the entry C Progra 1 Rockwe 1 RDM Paths is required in the PATH variable for the FTU32 to work correctly If you are installing on Windows NT the entry C Program Files Rockwell Software RDM is required in the PATH variable in the Environment tab of the System Properties dialog box Choose Next to approve th
84. oad A Current Application is a file that is currently selected and running on the Panel View terminal To view the Current Application s transfer parameters switch the Panel View terminal to Configure mode At the Panel View terminal choose the Terminal Network Setup button in the Terminal Configuration screen to display the Terminal Network Setup screen Exit the screen after you finish viewing the transfer parameters Go to step 7 To download with transfer parameters different from those of the Current Application or if you don t have a Current Application selected switch the PanelView terminal to Configure mode At the PanelView terminal choose the Transfer Setup button Go to step 2 2 Select the Network tab 3 Choose Network Direct as the Address Source When you choose Network Direct the configuration parameters from the application file are disabled 4 Select DH or ControlNet as the network type 4 4 Downloading 1000e 1200e 1400e Application Files In the examples below the first screen displays a ControlNet transfer setup The second screen displays a DH transfer setup Transfer Setup Address Application B Yes Auto Source _ RIO Pass Through No Restart F20 Network Direct F21 ControlNet Terminal Network Address 1 99 decimal Network Type F1 Transfer Setup Address Application Source RIO Pass Through F20 Network Direct DH Terminal Network Address 0 77 octal N
85. olbar In the General tab of the System Options dialog box select Auto Save All Settings to automatically save all settings when you exit You only need to select this check box once because your selection becomes the application default If Auto Save All Settings is not selected there is a Save Settings button in the main download dialog box If Auto Save All Settings is selected the Save Settings button is hidden To initiate the application file download gt Choose the Start Download button A progress dialog box appears that shows the status of the download Download Application In Progress Source FileName pvd 689257 bytes Destination FileName pyd on Memory Partition 2 HERRERO RRR Started 8 25 98 11 29 54 AM Estimated time to completion 12 seconds Abort Transmission Details Checking compatability Formatting destination Working If an error occurs during the download process see Chapter 6 Troubleshooting for the PanelView e Transfer Utility 32 Selecting Communication Hardware and Driver Packages Chapter 5 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers This chapter provides instructions for configuring communications settings when planning to transfer application files and Alarm History files between the Panel View 1000e 1200e 1400e terminals and the development computer The communication settings must be configured before a transfer can
86. one Paneiview Teaninal C Tirik Patty j Siseon Prena 5 hey bout fora pon PIC hy thes PT bearer pera sites appl reals Shadian frare te doled pout diinon aoe To select the network gt Specify DH or ControlNet as the network to which your PC is connected To select the driver 1 Click the Refresh List button to refresh the list of drivers 2 Select a driver from the list of available drivers Driver options include serial and RSLinx ports When selecting a driver Serial 1 and Serial 2 can be used to communicate directly with a 1770 KF2 KE or 1770 KFC without using RSLinx The other driver selections need RSLinx which can be installed on the development computer For details about installing RSLinx see the RSLinx user documentation Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 5 11 Before the RSLinx driver appears on the driver list you must first configure the RSLinx driver and then refresh the list of available drivers To configure an RSLinx driver you must start RSLinx by clicking the Invoke RSLinx button To refresh the list of available drivers choose the Refresh List button p Note Serial 1 and Serial 2 drivers enable you to configure two different serial setups for example baud rates Also they can accommodate the two communication ports on many computers Refer to the physical communication ports on your computer to determine the correct port for your ap
87. open Windows applications If you have done that choose Next 5 In the registration window enter registration information about your copy of the FTU32 Registration information is on the software registration card in your PanelBuilder 1400e or Transfer Utility package 6 Choose the drive and directory in which the FTU32 will be installed By default this is C AB PB1400E FTU32 To change the destination drive or directory type the new drive and or directory in the Program Files box Then choose Next Publication 2711E UM003B EN P 2 24 Working with the PanelView e Transfer Utility 32 Installing the FTU from the PanelView 1200 1400e Transfer Utilities CD on Windows 95 or Windows 3 x Publication 2711E UM003B EN P 7 Choose the program folder program group in which you want to install the FTU32 s icons which include a Readme file icon the Transfer Utility icon and an Uninstall icon By default the icons are installed in the PanelBuilder 1400e program folder Then choose Next 8 Choose whether the installation utility will modify the AUTOEXEC BAT file If you are installing on Windows 95 the entry C Progra 1 Rockwe 1 RDM Paths is required in the PATH variable for the FTU32 to work correctly If you are installing on Windows NT the entry C Program Files Rockwell Software RDM is required in the PATH variable in the Environment tab of the System Properties dialog Choose Next to approve the changes an
88. or more information rary pre rg aah 1 Start the PanelView 1200 1400e Transfer Utility using the method previously described for your operating system Upload Manm History Ci Paneview 1700 Tranaker CinleP i Ala 2 Choose PanelView 1200 Transfer from the Transfer menu The i following screen is displayed Publication 2711E UM003B EN P Working with the PanelView e Transfer Utility 32 2 31 Exiting the PanelView 1200 When you have finished transferring applications exit the Panel View Transfer Utility 1200 Transfer Utility To exit the PanelView 1200 Transfer Utility 1 Choose Exit from the menu bar The Exit menu appears Transfer Exit Yes exit Cancel Exit 2 Choose Yes exit and press ENTER You will return to the PanelView 1200 1400e Transfer Utility screen If you don t want to quit choose Cancel Exit The Panel View 1200 Transfer Utility remains active 3 Quit the Panel View 1200 1400e Transfer Utility by choosing Exit from the Transfer menu pressing ALT F4 or clicking on the Close button Exiting the PanelView When you have finished transferring applications exit the Panel View 1200 1400e Transfer Utility 1200 1400e Transfer Utility To exit the PanelView 1200 1400e Transfer Utility gt Choose Exit from the Transfer menu press ALT F4 or click on the Close button Publication 2711E UM003B EN P Uploading PanelView 1000e 1200e 1400e Application Files Chapter 3 Uploading 1000e
89. ork F17 F18 Baud Rate F1 F2 Error F3 Cancel OK F15 F16 To change the settings choose the Baud Rate Parity or Error buttons to move the check mark to the setting you want Baud Rate The speed at which data is transmitted over the serial cable The default setting for a serial transfer is 9600 baud e Parity Used to check for accurate transmission of the data between the development computer and terminal The default setting is None e Error Used to check for errors in the data transmission Error checking is either CRC cyclical or cyclic redundancy check BCC block check character BCC is the default setting The settings that are defined in the Transfer Setup screen must match the Transfer Utility s settings When you have selected the required settings choose OK to exit this screen To download an application serially in the Terminal Configuration screen choose the Transfer Application button to display the Transfer Application screen Downloading 1000e 1200e 1400e Application Files 4 3 Transfer Application Serial Memory Card F17 F18 Ready for Transfer To prepare the PanelView terminal for a network download 1 To use the Current Application s transfer parameters make sure the Panel View terminal is in Run mode to start running the application and then follow the next procedure to configure the PanelView e Transfer Utility 32 for the downl
90. ot selected there is a Save Settings button in the main download dialog box If Auto Save All Settings is selected the Save Settings button is hidden Chapter 6 General Upload Download Problems Troubleshooting for the PanelView e Transfer Utility 32 This chapter describes how to diagnose and solve problems you might encounter while transferring applications to Panel View 1000e 1200e 1400e terminals Panel View e Transfer Utility 32 has context sensitive online help When an error message appears during any stage of file or application transfer press F1 on the keyboard to display probable causes of the error In Panel View e Transfer Utility 32 errors are categorized as either warnings or problems Error messages are preceded by a colored icon that indicates the severity of the error Icon Description Indicates a problem you may encounter while uploading or downloading E3 PanelView application files or uploading alarm history files For problems the file transfer is immediately halted Indicates a warning you may receive during a file transfer advising you to 4 take or avoid a specific action For warnings you have the option of ignoring them and continuing with the file transfer For all Panel View communication problems the Panel View e Transfer Utility 32 waits for a period of time called a timeout before displaying a communication error message You can change this timeout duration by selecting System Op
91. plication 3 Choose the Configure Driver button If you have selected an RSLinx port choose the Configure Driver button to open the RSLinx utility When you return to the Transfer Utility choose the Refresh List button to refresh the list of drivers Refer to the RSLinx user documentation for information on using the utility If you have selected Serial 1 or Serial 2 the Communication Driver Configuration dialog box appears Comm ikomion Driver Caig aiia 4 Define the settings in the Communication Driver Configuration dialog box as follows Baud Specify the data transfer rate between your computer and the 1770 KF2 KE or 1770 KFC This must match the baud rate configured for the 1770 KF2 KE or 1770 KFC The default setting is 9600 Port Specify COM1 COM2 COM3 or COM4 as the serial port used to connect the serial cable to the 1770 KF2 KE or 1770 KFC The default setting is COM1 5 12 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers Parity Specify None or Even for the type of error checking to be used This must match the parity configured for the 1770 KF2 KE or 1770 KFC The default setting is None Error Specify the error detection protocol used by the device BCC is Block Check Character and CRC is Cyclic Redundancy Check This must match the error checking protocol configured for the 1770 KF2 KE or 1770 KFC The default setting is BCC To set the transfer path Set the trans
92. pth information about the objects that you Pane Builder 1400e Configuration Software for Windows 2711E 6 15 can create for application screens Reference Manual Information about installing configuring PanelView 1000e 1200e and 1400e Operator Terminals 2711E 6 17 maintaining and troubleshooting PanelView 1000e 1200e and 1400e operator terminals Also includes specifications for the terminals User Manual For See Preface P 3 Publication Number A complete list of current Allen Bradley documentation including ordering instructions Also indicates whether the documents are available on CD ROM or in multiple languages Allen Bradley Publication Index D499 A glossary of industrial automation terms and abbreviations Allen Bradley Industrial Automation Glossary AG 7 1 P 4 Preface Technical Support Services Allen Bradley Support Conventions Used in This Manual If you have questions about the PanelView e Transfer Utility 32 consult the online help and user documentation first If you can t find the answer take advantage of our Technical Support Fax Back system available 24 hours a day 7 days a week at 1 440 646 6701 Or browse our technical document library on the World Wide Web at http www ab com mem technotes kbhome html Alternatively contact Allen Bradley Technical Support 1 Allen Bradley Drive Mayfield Heights Ohio 44124 6118 or call 1 440 646 5800 or fax 1 4
93. r prepare the Panel View terminal for the upload e configure the Panel View e Transfer Utility 32 for the upload e initiate the alarm history file upload To prepare the PanelView terminal for a serial upload 1 Using the hardware keyswitch or the Goto Configure Mode button switch the PanelView terminal to the Configure mode 2 In the Terminal Configuration screen choose the Transfer Setup button to display the Transfer Setup screen Transfer Setup Serial Network F17 F18 Baud Rate F1 Parity F2 Error F3 Cancel OK F15 F16 3 To change the settings choose the Baud Rate Parity or Error buttons to move the check mark to the setting you want e Baud Rate The speed at which data is transmitted over the serial cable The default setting for a serial transfer is 9600 baud e Parity Used to check for accurate transmission of the data between the development computer and terminal The default setting is None e Error Used to check for errors in data transmission Error checking is either CRC cyclical or cyclic redundancy check BCC block check character BCC is the default setting The settings that are defined in the Transfer Setup screen must match the Transfer Utility s settings Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 11 4 When you have selected the required settings choose OK to exit this screen 5 To upload the terminal
94. r A 4 RIO Pass Through 2 12 selecting driver 5 1 DH addresing remote station address A 1 DH addressing local station address A 1 Logix55xx address A 1 DH RIO Pass Through 2 12 Direct transfers 1 4 Downloading 1 3 DH RIO Pass Through 1 4 methods 1 3 tips 1 4 1 7 Driver packages selecting 5 1 E Error checking 5 9 5 12 5 15 Error message 6 1 Error detection protocol 5 9 5 12 5 15 Ethernet equipment required for transfer 2 12 selecting driver 5 1 Exiting from Transfer Utility 2 28 2 31 H Hardware requirements minimum 2 1 Help See Online help Installation requirements 2 1 Installing FTU floppy disks on Windows 3 x 2 21 2 24 on Windows 95 2 17 2 21 2 23 2 24 on Windows NT 2 17 2 23 INTERCHANGE software 1 6 1 7 and device drivers 1 6 Invoke RSLinx 5 11 5 14 K KA modules A 4 L Local station address ControlNet A 1 DH A 1 Logix55xx address ControlNet A 1 DH A 1 M Modules KA A 4 Index 2 RM A 4 N Network accessed 5 10 5 13 O Offlink address A 2 Online help P 4 2 1 6 1 P PanelBuilder 1400e support services P 4 PanelBuilder software 2 2 for doing file transfers P 1 1 2 PanelView 1200 1400e Transfer Utility exiting 2 31 starting 2 30 from Windows 3 x 2 29 from Windows 95 2 2
95. r PanelView 1000e 1400e Series F and later terminals 2711 NC1 for PanelView 1200e 1400e terminals Series E and earlier for connecting the computer to the terminal Alarm History files directly by connecting the serial ports on the computer and Panel View terminal This is a serial file transfer Network Upload Download You can upload applications or Alarm History files once you have connected the Panel View terminal and computer to the DH or ControlNet network You can download applications between the computer running the Transfer Utility and the Panel View terminal over the DH or ControlNet network without taking the terminal out of Run mode Since the serial port is not used for network transfers you can print from the PanelView terminal without changing the serial cabling of the terminal 1 4 Introducing the PanelView e Transfer Utility 32 File Transfer Tips To do network downloads you can use RSLinx drivers RSLinx Lite is included on floppy disks with your PanelBuilder 1400e software package A B Catalog Number 2711E ND1 or Transfer Utility software package A B Catalog Number 2711E ND7 you must install RSLinx separately For RSLinx installation procedures see the RSLinx user documentation provided For a complete list of hardware and driver requirements refer to the table in Chapter 5 Note For information about the ControlNet Communication Interface Card requirements for uploading and downloading over ControlNet
96. re from the CD refer to the Floppies txt file in the root directory of the CD To install the FTU 1 Start Windows 95 or Windows 3 x If you re already in Windows close all open Windows applications 2 Insert the CD ROM in the drive The CD ROM begins to run automatically 3 If the install does not start automatically and you are running on Windows 95 choose Run from the Start button and select setup exe from the CD ROM drive or select setup exe from Windows Explorer If you are running on Windows 3 x choose Run from the File menu In the Run dialog box type d setup where d is the drive containing the File Transfer Utility CD ROM and press Enter Hun Current Deectory CAPPS Lonmin aired Lina O Rue Minimize 4 In the Welcome dialog box choose Next 5 If you are installing on Windows 95 the Select Version dialog box appears Choose Version 3 and then choose Next If you are installing on Windows 3 x the Select Version dialog box does not appear Version 3 is automatically selected Publication 2711E UM003B EN P 2 22 Working with the PanelView e Transfer Utility 32 Publication 2711E UM003B EN P 6 10 11 12 In the Choose Applications dialog box choose File Transfer Utility as the application you want to install You can choose more than one application to install Then choose Next E Fite Trewern l Sent rw Upped The Welcome dialog box for the File Transfer Utility
97. re the downloaded application will be stored The default is Memory Partition 2 Memory Partition 1 is the terminal s first memory partition It is typically used for firmware storage and is not available for application file storage unless the firmware is located on a PCMCIA card Memory Partition 2 is the terminal s second memory partition It can only be used for application file storage Card Partition 1 is the first partition on a card with two application partitions or the partition on the card with a single partition If the firmware is located on a PCMCIA card then this storage area is not available for applications Card Partition 2 is the second partition on a card with two application partitions 4 8 Downloading 1000e 1200e 1400e Application Files If you do not want to format the storage area or if you cannot format the storage area the following pop up window is displayed to provide information about the storage area Insufficient Free Space in Download Destination or Partition Not Available The file FileName pyd 689257 bytes is too big to fit in Memory Partition 2 or the partition is not available Select another PY Terminal Storage Destination Space Free Max Size PY Terminal Storage bytes bytes Status Memory Partition 1 1 0 1815040 Storage reserved Memon Partition 2 78848 257024 Insufficient space in storage Card Partition 1 ce 0 1815040 Storage selectable Card P
98. rect Modbus Internal Drivers Serial 1 or 2 1770 KF 2 KE Network DH Internal Drivers Serial 1 or 2 RSLinx AB_DF1 Remote 1 0 DH Internal Drivers Serial 1 or 2 Pass Through RSLinx AB DF1 1784 KT 1784 KTX Network DH RSLinx AB_KT PCMK Remote 1 0 DH RSLinx AB KT Pass Through 1770 KFC Network ControlNet Internal Drivers Serial 1 or 2 RSLinx AB_DF1 Remote 1 0 ControlNet Internal Drivers Serial 1 or 2 Pass Through RS Linx AB DF1 1784 KTC Network ControlNet RSLinx AB KTC 1784 KTCX Remote 1 0 ControlNet RSLinx AB KTC Pass Through Ethernet Network Card Remote I O Ethernet RSLinx AB_ETH Pass Through If you have this FTU Version 3 Decide which Table 5 B Table of PC Host Hardware and Applicable Drivers Select Network Choose one of these Select the corresponding driver communication transfer link to use Type and driver packages hardware Address PC COM Port RS 232 Serial DF 1 Direct Internal File Transfer Serial 1 or 2 Utility WIN LINX 1770 KF 2 KE to DH DH amp PLC 5 CHO INTERCHANGE INTERCHANGE Port1 8 1770 KF2 KE Network Direct DH Internal File Transfer Serial 1 or 2 Utility WIN LINX 1770 KF 2 KE to DH DH amp PLC 5 CHO WIN LINX using INTERCHANGE to DH INTERCHANGE Interchange Port 1 8 Remote 1 0 DH Internal File Transfer Serial 1 or 2 Pass Through Utility WIN LINX 1770 KF 2 KE to DH DH amp PLC 5 CHO WIN LINX using INTERCHANGE to DH INTERCHANGE Interchange Port 1
99. rk correctly Choose Next to approve the changes and continue The setup utility shows a summary of the choices you made in the preceding dialog boxes To make any changes choose the Back button Otherwise choose Next to begin the installation After all the applications have completed installing you are prompted to reboot your computer You may reboot immediately or later but you must reboot before you can run the Transfer Utility or other applications successfully If you want to upload or download PanelView files over the PLC networks after you finish installing the Transfer Utility you also need to install INTERCHANGE or WINtelligent LINX software If you do not have this software contact Allen Bradley Technical Support for assistance Publication 2711E UM003B EN P 2 26 Working with the PanelView e Transfer Utility 32 Starting the PanelView e Transfer Utility 32 Version 5 FTU32 Publication 2711E UM003B EN P Do not cancel the installation while it is in progress If you want to undo the installation let the installation finish then use the Uninstall Transfer Utility to remove all the installed files and to update the registration For information on how to start and exit from the PanelView 1200 Transfer Utility see the PanelView 1200 Transfer Utility User Manual Publication Number 2711 UM010B EN P PanelView e Transfer Utility 32 FTU32 Version 5 runs on Windows NT 2000 SP2 or Windows 95 This section des
100. rmat the terminal storage while a selected application is running Deselect the application that is running if you can Or download the application to another terminal storage ControlNet Addressing DH Addressing Appendix A Constructing the Transfer Path This appendix explains how to construct the transfer path in the Panel View e Transfer Utility 32 for network and Remote I O Pass Through file transfers This appendix explains the different transfer path formats if you are entering the transfer path manually Local Station Addressing For a development computer connected to the same ControlNet network as the Panel View terminal valid station numbers are between and 99 decimal Logix55xx Addressing For a Logix55xx connected to a Panel View terminal on a ControlNet network valid station numbers are Station Address Valid Entries Il b ss I address of CNB module for CNet applications 1 99 decimal b backplane address 1 ss slot number of Logix55xx Processor depends on chassis size Local Station Addressing For a development computer connected to the same DH network as the PanelView terminal valid transfer paths are between 0 and 77 octal Logix55xx Addressing For a Logix55xx connected to a Panel View terminal on a DH network valid station numbers are between 0 and 77 octal Remote Station Addressing A development computer can communicate with Panel View terminals on remote DH networks Remot
101. rminal The download application cannot be made current after download Do you want to continue Warning 4223 The download application s network type is not supported by the PanelView terminal s firmware Choose Yes to continue Choose No to cancel the file transfer The application will not be selected Problem Troubleshooting for the PanelView e Transfer Utility 32 Cause What to do The application s of s type cannot run ona s type terminal The application cannot be made current after download Do you want to continue Warning 4224 The download application s type is incompatible with the PanelView terminal s type Choose Yes to continue Choose No to cancel the file transfer The application will not be selected The application is not a 1200e touch screen application It cannot run on this 1200e touch screen terminal The application cannot be made current after download Do you want to continue Warning 4225 The download application s type is incompatible with the PanelView terminal s type Choose Yes to continue Choose No to cancel the file transfer The application will not be selected Unable to format the terminal storage s The current selected application is running on the PanelView terminal Error 4227 The storage cannot be formatted because the current application is running from that storage and the download file is not to be made current
102. rom the Options menu or g from the toolbar System In the General tab of the System Options dialog box select Auto Save All Settings to automatically save all settings when you exit You only need to select this check box once because your selection becomes the application default If the Auto Save All Settings option is not selected there is a Save Settings button in the main download dialog box If Auto Save All Settings box is selected the Save Settings button is hidden To initiate the application file upload gt Choose the Start Upload button A progress dialog box appears that shows the status of the upload Upload Application In Progress Source FileName pvd 10929 bytes on Memory Partition 2 Destination E 4ppFiles FileName pvd Started 8 25 98 11 37 18 AM Ended 8 25 98 11 37 36 AM Transfer failed Abort Transmission Details Determining terminal status Done Checking compatability Done Transferring file Failed Possible Causes The P terminal must be in the Transfer Application Serial screen The termin The baud rate of the PC s serial driver may not match the settings of the PY termir The serial cable may be dis connected or the wrong cable is being used f If an error occurs during the upload see Chapter 6 Troubleshooting for the PanelView e Transfer Utility 32 3 8 Uploading 1000e 1200e 1400e Application Files and Alarm History Files Uploading
103. s The specified transfer path may be incorrect for the target Pass Through device Check the Pass Through device for its address Ensure it matches the Transfer Utility s transfer path For Remote I O Pass Through transfers The wrong development computer network driver may be used or incorrectly configured Ensure the correct network driver is used and use the communication software to configure the network driver For Remote I O Pass Through transfers The terminal is incorrectly in the Configure mode it must be in Run mode Switch the P anelView terminal to Run mode No KTCx card found on PanelView terminal The download application cannot be made current when download completes Do you want to continue Warning 4211 A required KTCx card is not installed in the PanelView terminal Choose Yes to continue Choose No to cancel the file transfer The application will not be selected No serial card found on PanelView terminal The download application cannot be made current when download completes Do you want to continue Warning 4212 A required serial card is not installed in the PanelView terminal Choose Yes to continue Choose No to cancel the file transfer The application will not be selected No KTCs card found on PanelView terminal The download application cannot be made current when download completes Do you want to continue Warning 4213 A required KTCs card is not i
104. scription Overwrite Existing File If a file of the same name already exists in the terminal s storage it will be erased automatically Clear the check box if you want to be warned before the existing file is erased The default is to prompt before overwriting the existing file Format If Full All files downloaded to the terminal occupy space even if they are erased The only way to free up space is to format the terminal storage If Format If Full is selected the terminal s storage will automatically be formatted if there is not enough space to accommodate the downloaded file Clear the check box if you want to be warned before the terminal storage is reformatted or if you want to be able to select another storage location if the selected one is full The default is No Important The terminal s storage can hold more than one application file If you select Format If Full all files in the selected storage will be removed Ensure you have backups of any files you do not want to delete See the instructions for uploading files in Chapter 3 to back up terminal files Download If Newer When this box is checked the application file is downloaded only if it is newer than the file of the same name in the terminal s memory The default is No If the Make Application Current box is not selected the Download If Newer option is not available Ignore Compatibility Warnings When this box is cleared a warning messag
105. se your selection becomes the application default If Auto Save All Settings option is not selected there is a Save Settings button in the main download dialog box If the Auto Save All Settings is selected the Save Settings button is hidden To start the alarm history file upload gt Choose the Start Upload button A progress dialog box appears that shows the status of the upload Upload Alarm History In Progress Source Alarm History on Panel iew Terminal Destination E AppFiles FileName csv HERR RROR RRR RRR RRR RRR RRR 100 Started 8 25 98 11 44 08 AM Ended 8 25 98 11 44 44 AM Upload complete Abort i Transmission Details Determining terminal status Done Checking compatability Done Transferring file Done Summary Statistics Data transferred 12137 bytes Transfer duration O minutes 36 seconds Data throughput 337 bytes second If an error occurs during the upload process see Chapter 6 Troubleshooting for the PanelView e Transfer Utility 32 Downloading PanelView 1000e 1200e 1400e Application Files Chapter 4 Downloading 1000e 1200e 1400e Application Files This chapter describes how to download application files using the various transfer methods described in Chapter 2 Working with the PanelView e Transfer Utility 32 For file transfers over ControlNet DH or Remote I O Pass Through be sure the Panel View terminal address is correct otherwise the transfer could
106. software package A B Catalog Number 2711E ND7 You can also create your own floppy disks of the Panel View e Transfer Utility 32 software from the CD this manual was on For instructions on how to create floppy disks of the software from the CD refer to the Floppies txt file in the root directory of the CD The CD ROM includes two install versions for the Transfer Utility software e Version 3 This version offers you the PanelView 1200 1400e Transfer Utility FTU on an operating system that uses Windows 3 x or Windows 95 Version 3 supports INTERCHANGE and WINtelligent LINX drivers for Panel View 1000e 1200 1200e and 1400e file transfers e Version 5 This version offers you the PanelView e Transfer Utility 32 FTU32 software on an operating system that uses Windows 95 or Windows NT Version 5 supports RSLinx drivers for Panel View 1000e 1200e and 1400e file transfers If your operating system is Windows 3 x the CD ROM will install FTU Version 3 If your operating system is Windows 95 you have a choice of installing FTU Version 3 or Version 5 If your operating system is Windows NT the CD ROM will install FTU Version 5 also called FTU32 Installing FTU32 from PanelBuilder 1400e CD ROM on Windows 2000 SP2 NT 95 Working with the PanelView e Transfer Utility 32 2 17 Panel View e Transfer Utility 32 FTU32 Version 5 is provided on the PanelBuilder 1400e CD ROM The software installation program creates a directory
107. space Choose another drive that has available disk space or free up some space on the disk drive that is full You must specify a source file name to download Error 4117 A source file name was not specified Enter the source file name to download or press Browse to select the file to download The terminal application filename s is too long It will be truncated to 8 characters before being downloaded Warning 4118 The file name exceeds the maximum 8 characters The file name is automatically truncated to 8 characters The PanelBuilder PVC file s cannot be used to retrieve communication transfer parameters Specify valid PanelView terminal runtime PVD files only Error 4121 PanelBuilder pvc files cannot be downloaded to the terminal Specify valid P anelView terminal runtime pvd files only You must specify a valid runtime terminal file from which transfer parameters are to be retrieved These parameters will be used to configure the current file transfer Error 4122 Either the file name is blank the file is not a valid pvd file or the file does not exist Enter a valid runtime file or press Browse to search for one Unable to display the release notes for this application The text file located at S cannot be accessed Error 4123 The Readme ttt file from the install cannot be found Reinstall the application and try again The
108. t connecting the serial cable to the terminal and without going from terminal to terminal with a PC You need the same equipment for Remote I O Pass Through transfers over either DH ControlNet or Ethernet as listed previously for the DH and ControlNet networks In addition you need one of the following e for a DH transfer a PLC 5 or SLC 5 04 processor is required for PLC SLC series revision requirements refer to Chapter 5 of the PanelView 1000e 1200e and 1400e Operator Terminals User Manual e for a ControlNet transfer a PLC 5C or PLC5C15 processor is required for PLC series revision requirements refer to Chapter 5 of the PanelView 1000e 1200e and 1400e Operator Terminals User Manual e for an Ethernet transfer a PLC 5E processor or a 1785 ENET sidecar module is required for PLC series revision requirements refer to Chapter 5 of the PanelView 1000e 1200e and 1400e Operator Terminals User Manual You also need RSLinx Lite software Version 2 0 or later RSLinx Lite is included with your PanelBuilder 1400e software package A B Catalog Number 2711E ND1 or Transfer Utility software package A B Catalog Number 2711E ND7 Figures 2 8 and 2 9 show how the application file is transferred from the development computer to the PLC and then to the Panel View terminal Figure 2 10 shows how the application file is transferred through an Ethernet link over the Remote I O network and then to the Panel View terminal Work
109. t to clear the alarms Ignore Clear Confirmation The Ignore Clear Confirmation option is enabled if Clear Alarm History after Upload option is selected This option is grayed out and disabled if the Clear Alarm History after Upload option is not selected If this box is not selected a confirmation dialog box is displayed at the beginning of the upload Press Yes to indicate you want to clear unacknowledged alarms in your alarm history Press No to indicate you do not want to clear the alarms After the confirmation the alarm history upload continues to completion If this box is selected the confirmation dialog box is not displayed Important If you need to turn off a relay or buzzer to acknowledge alarms we recommend that you do not use this feature To switch off this feature select Ignore Clear Confirmation 6 Click OK to save your settings and exit from the File Transfer Options dialog box 7 Configure communications settings for the transfer following instructions in Chapter 5 Configuring Communications Settings for 1000e 1200e 1400e Application Transfers 3 16 Uploading 1000e 1200e 1400e Application Files and Alarm History Files 8 To save your settings choose System Options from the Options menu or Be from the toolbar In the General tab of the System Options dialog box select Auto save All Settings to automatically save all settings when you exit You only need to select this check box once becau
110. the PanelView 1000e 1200e 1400e Alarm History File The Panel View e Transfer Utility 32 allows you to upload an application s historical alarm data from Panel View 1000e 1200e 1400e terminals The Alarm History file can be uploaded using any of the upload methods Serial Network or Remote I O Pass Through Note The Upload Alarm History function works only for PanelView 1000e 1200e 1400e terminals with Version 02 00 00 or later firmware Alarm History Information The uploaded alarm history information is in comma separated values format csv which is ASCII text compatible The header information with the name of the terminal s current application file number of alarms and the time and date of the upload is the first line in the uploaded file An example of the alarm history header is as follows my_app 128 97 06 20 23 59 59 The header is followed by a line that lists the boxes for the alarm record information For example Alarm Trigger Alarm Message Trigger Date Trigger Time Acknowledge Date Acknowledge Time The third and subsequent lines include the alarm records each on a separate line starting with the most recent alarm See the following table for the format of each box in the alarm record Uploading 1000e 1200e 1400e Application Files and Alarm History Files 3 9 Box Data Alarm Trigger Signed long integer value Alarm Message The alarm message associated with the trigger v
111. the cable attach the PanelView upload download cable restart your computer and retry the download Message Troubleshooting for the PanelView e Transfer Utility 32 6 11 Cause What to do During a pass through download or upload the DH cable is not connected correctly Check the cable connections During a pass through download or upload the terminal is not in pass through mode that is not in the application transfer screen On the PanelView terminal go to the Transfer Setup screen select the Network tab define an RIO Pass Through and then switch the terminal into Run mode During a pass through download or upload the DH network address is not correct Check the PLC s correct network address For details on PLC network addresses see your PLC documentation Cannot load Linx Dynamic Link Library You have chosen a WINtelligent LINX or RS Linx driver that is not installed Choose a native serial driver Problem with communication driver or hardware You have chosen the wrong INTERCHANGE port Choose the correct port You have chosen an INTERCHANGE port that is set up incorrectly Check that your configuration settings are correct your network addresses are correct and you are using the correct equipment Host PC failed to communicate with PanelView terminal There is no link between the PanelView terminal and the host PC Check the link between t
112. tions from the Options menu Then select the General tab in the System Options dialog box In the Communication Timeout Duration field specify how long you want the transfer utility to wait before displaying a message after a communication error has occurred Use the following table to identify problems you may encounter while trying to upload or download Panel View application files or upload alarm history Problem Cause What to do Application file won t download or upload You are using the wrong serial cable Check the serial cable The application file is too large Ensure the memory size of the application file does not exceed the User Memory Limit For information on application file size see Chapter 1 Introducing PanelView Terminals in the PanelView 1000e 1200e 1400e Operator Terminals User Manual 6 2 Troubleshooting for the PanelView e Transfer Utility 32 Problem Cause What to do Application file won t download or upload con t The computer is not connected to the PanelView terminal Connect the computer to the PanelView terminal The terminal s serial communication port is not configured for upload download Configure the serial communication port for upload download The PanelView terminal is turned off Turn on the PanelView terminal The PanelView terminal is in the wrong mode when a Serial upload download is attempted To transfer an application file serially e
113. u aware of safety considerations ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attention statements help you to e identify a hazard e avoid a hazard recognize the consequences IMPORTANT Identifies information that is critical for successful application and understanding of the product PanelBuilder PanelView Data Highway Plus DH SLC SLC 500 RSLinx WINtelligent LINX and INTERCHANGE are trademarks and PLC PLC 2 and PLC 3 are registered trademarks of Rockwell Automation IBM PC AT XT PS 2 and PC DOS are registered trademarks of International Business Corporation Microsoft Windows Windows NT and Windows 2000 are trademarks and Microsoft MS and MS DOS are registered trademarks of Microsoft Corporation Ethernet is a registered trademark of Digital Equipment Corporation Intel and Xerox Corporation All other brand and product names are trademarks or registered trademarks of their respective companies and are hereeby acknowledged Table of Contents Introducing the PanelView e Transfer Utility 32 Working with the PanelView e Transfer Utility 32 Preface Before You Begin nc ccd 2csicu oS weeds Suse deve ceceees as P 1 Purpose of This Manual 00 cece eee teas P 1 Contents of This Manual 000 eee eee eee P 2 Related Publications svec cociekiawebwecevesenveveuees P 2 Technical
114. u want to delete the transferred application start the file transfer again with the same application Immediately cancel the file transfer The second file transfer overwrites the first file transfer Bad communication PV missed a download packet Error 2118 There may be an unrecoverable error Exit and run the program again Could not write data to the upload file Error 2119 The specified upload application file cannot be written Choose another drive that has available disk space or free up some space on the disk drive that is full The destination drive has insufficient free space to perform the requested operation Free up some disk space on the target drive and try The destination drive has insufficient free disk space Choose another drive that has available disk space or free up some space on the disk drive that is full again Error 2120 PLC Inhibit bit is set The application that is currently running in Check the PLC inhibit bit Reset the bit if Error 3101 the PanelView terminal may be inhibiting file you want to continue with the transfer transfers The selected terminal storage is out of space for the download application Do you want to select another terminal storage The selected terminal storage area has insufficient storage space in the PanelView terminal Choose Yes to select another terminal storage area Choose No to cancel the download
115. uilder Utility 32 applications 2 Working with the Step by step instructions for installing the PanelView e Transfer PanelView e Transfer Utility 32 and starting it Utility 32 for the first time Also includes instructions for exiting from the utility 3 Uploading Explains how to upload application files and 1000e 1200e 1400e alarm history files using serial transfer network Application Files and transfer for DH and ControlNet and Alarm History Files Remote I O Pass Through transfers 4 Downloading Explains how to download application files 1000e 1200e 1400e using the various transfer methods Application Files 5 Configuring Explains how to set the common Communications communication parameters for uploading and Settings for downloading files 1000e 1200e 1400e Application Transfers 6 Troubleshooting for the Explains how to diagnose and solve problems PanelView e Transfer Utility 32 you might encounter when using the PanelView e Transfer Utility 32 Related Publications The following publications contain additional information about the PanelBuilder application as well as about Panel View terminals operation Contact your local Allen Bradley office or distributor for copies of any of these publications For See Publication Number Comprehensive instructions for working with the PanelBuilder 1400e Configuration Software for Windows User 2711E 6 14 PanelBuilder 1400e Configuration Software Manual application In de
116. will current when download completes not be selected Do you want to continue Warning 4202 No ControlNet KTCx driver found on PanelView A required ControlNet Unscheduled driver is Choose Yes to continue Choose No to terminal not installed in the PanelView terminal cancel the file transfer The application will The download application cannot be made not be selected current when download completes Do you want to continue Warning 4203 No Modbus driver found on PanelView terminal A required Modbus driver is not installed in Choose Yes to continue Choose No to The download application cannot be made the PanelView terminal cancel the file transfer The application will current when download completes not be selected Do you want to continue Warning 4204 6 6 Troubleshooting for the PanelView e Transfer Utility 32 Problem Cause What to do No ControlNet KTCs driver found on PanelView terminal The download application cannot be made current when download completes Do you want to continue Warning 4205 A required ControlNet Scheduled driver is not installed in the PanelView terminal Choose Yes to continue Choose No to cancel the file transfer The application will not be selected Host PC failed to communicate with PanelView terminal Error code RDM number 0x X Error 4209 For serial transfers The PanelView terminal is incorrectly in Run mode it must be in Configure mode