F940GOT Series( F94*GOT-*WD

image

Contents

1. FOGT 40LTS FOGT 40UMB Data exchange cable GOT lt Personal computer lt 9 pin D sub gt Battery for Alarm history sampling and current time data retertion Transparent protection sheet for F940GOT 5 pieces Backlight for F940GOT Data transfer adapter F9GT 40FMB Data transfer adapter Flash memory built in Caution During abnormal communication including cable breakages when monitor is executed within the GOT communication between the GOT and programmable controller CPU is interrupted It is then impossible to operate switches or devices in the PLC through the GOT Communication and normal operation resumes when the GOT system is correctly configured DO NOT configure emergency stop or safety features to operate through the GOT and be sure that there is no adverse consequences in the event of a GOT PLC communications malfunction Note AN e Do not lay signal cables near high voltage power cables or allow them to share the same trunking duct otherwise effects of noise or surge induction are likely to take please Keep a safe distance of more than 100 mm from these wires e Operate touch switches on the display screen by hand DO NOT use excessive force or attempt operate them with hard or pointed objects The tip of a screw driver pen or similar object for example may break the screen 1 2 Dimensions and Each Part Name Dime
2. Fixing the GOT Put hooks of the mounting brackets supplied in to the mounting holes of the GOT Tighten mounting bolts also supplied until the GOT is securely fixed Fix mounting bolts in all four positions above and below the GOT a Clamping bolt b Mounting bracket Note Make sure to tighten the clamping bolts with a torque of 0 3 0 5 Nm 4 Dimensions required inside the panel for installation lt ees gt When installing the GOT make sure that the inner dimensions shown on the right are available a PLC connection cable b Packing seal 5 0 20 or less b 4 Power Supply Wiring Caution A Cut OFF all external phases of power before installation or wiring to avoid electric shock or serious damage to the product Note e Wire the power supply using electric wires of 0 75 mm or more so that voltage drop will not occur Use M8 size crimp style terminals Securely tighten crimp style terminals with a torque of 0 5 0 8 N m so that errors can be avoided e Insure correct termination of the DC power source incorrect connection may result in unit failure or serious damage to the GOT being burnt e Attach a fuse of 2 A to the 24V DC power supply e Perform Class D 1002 or less grounding with an electric wire of at least 1 25 mm Never perform common grounding of the GOT and a strong power system Note e Use an external power supply to provide 24V DC The s
3. F943GOT OWD 3 Installation Note AN e Do not mount the GOT in an environment that contains dust soot corrosive or conducive dust corrosive or flammable gas or expose the unit to high temperatures dew condensation rain wind or impact and vibration If the GOT is used in such a place electrical shock fire malfunction damages or deterioration may occur e Never drop cutting chips or electric wire chips into the ventilation window of the GOT when drilling screw holes or performing wiring Such chips may cause fire failure or malfunction e Turn off the power before securely connecting any cables Poor connection may cause malfunction The GOT is designed to be mounted in a panel Install it using the following procedure 1 Preparing the panel surface On the panel surface cut a rectangular mounting slot of the Unit mm inches dimensions shown on the right a At this time space of 10 mm is required at each of the top F So and the bottom of the slot inside the panel for metal fixtures E AE X 5 as shown in 4 Dimensions required inside the panel for x installation ny 1 0 04 j 153 6 02 Note Make sure that the thickness of the panel surface is no more than 5 mm 0 20 2 Inserting the GOT into the panel surface Attach the packing seal to the GOT and insert the GOT from the front face of the panel surface a Packing seal b GOT c Mounting slot 3
4. for F9GT 40FMB Cautions A e Correctly connect the battery for memory backup Never charge disassemble heat burn or short circuit the battery If the battery is handled in such a way or fire may be caused e Always power OFF and remove the GOT from the panel before starting replacement of the backlight and battery If this is not the case the backlight may be dropped and cause injury or electrical shock sustained e Never disassemble or modify the GOT Disassembly or modification may cause failure malfunction or fire For repair please contact a service representative Note Turn OFF the power before connecting disconnecting cables Connecting disconnecting cables while the power is turned on will cause failure or malfunction caused When repairing liquid crystal screen please contact a service representative 6 1 Battery Replacement When the battery voltage drops a control device system information set by the screen design software turns ON The control device interlocks with an auxiliary relay in the PLC It is recommended to provide a lamp while utilizing the output of the PLC so that voltage drop can be monitored outside the GOT For details of control devices refer to the GOT F900 Series Operation Manual Note For approximately one month after the control device for battery voltage drop turns ON the battery will back up the alarm history sampling and the current time When the control device system informatio
5. ATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100 8310 HIMEJI WORKS 840 CHIYODA CHO HIMEuJI JAPAN
6. a MITSUBISHI GRAPHIC OPERATION TERMINALS MELSEGGOT cor F900 Changes for the Better F940GOT Series F94 GOT WD E Installation Manual JY992D94201D This manual contains text diagrams and explanations which will guide the reader in the correct installation safe use and operation of the F94 GOT WD E and should be read and understood before attempting to install or use the unit Further information can be found in the associated manuals list below Specifications are subject to change without notice Guidelines for the Safety of the User and Protection of the F94 GOT WD E This manual has been written to be used by trained and competent personnel The definition of such a person or persons is as follows a Any engineer using the product associated with this manual should be of a competent nature trained and qualified to the local and national standards These engineers should be fully aware of all aspects of safety with regards to automated equipment b Any commissioning or service engineer must be of a competent nature trained and qualified to the local and national standards c All operators of the completed equipment should be trained to use that product in a safe and co ordinated manner in compliance to established safety practices Note The term completed equipment refers to a third party constructed device which contains or uses the product associated with this manual Note s on the Symbols Us
7. e volume JY992D94701 separate volume JY992D94801 separate volume PDF files on CD ROM included with product PDF files on CD ROM included with product Included with the screen creation software JY992D68301 included with the screen creation software JY992D98601 Describes the specifications wiring and installation of F940GOT Series graphic operation terminal hardware Describes the operation and use of the GOT F900 Series graphic operation terminals and GT Designer2 Describes the operation and use of the GOT F900 Series graphic operation terminals GT Designer and FX PCS DU WIN E Describes wiring and installation of the GOT F900 Series graphic operation terminals Describes the operation of GT Designer2 SW D5C GTD2 E and data transfer to the GOT 900 Series Describes the specifications and setting of object functions in GT Designer2 SW D5C GTD2 E Describes the operation of GT Designer SW D5C GOTR PACKE and data transfer to the GOT 900 Series Refer to the help file Describes the operation of FX PCS DU WIN E screen creation software This manual contains explanations for installation and operating procedure of F9GT 40FMB data transfer adapter Manua Name Manual Number This manual contains explanations for F9GT 40UMB JY992D74101 Manual installation and operating procedure of F9GT 40UMB data transfer adapter Indispensable manual O Either manual i
8. ed in this Manual At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of equipment damage A 1 Indicates that the identified danger WILL cause physical and property damage Indicates that the identified danger could POSSIBLY cause physical and property e Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment All examples and diagrams shown in this manual are intended only as an aid to understanding the text not to guarantee operation Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples e Owing to the very great variety in possible application of this equipment you must satisfy yourself as to its suitability for your specific application Associated Manuals J Manual Name Manual Number Description F940GOT Series F94 GOT WD E Installation Manual GOT F900 OPERATION MANUAL describes GT Designer2 GOT F900 Series Operation Manual GOT F900 Series Hardware Manual connection diagram GT Designer2 Version1 Operating Manual GT Designer2 Version1 Reference Manual GT Designer Operating Manual FX PCS DU WIN E SOFTWARE MANUAL FOGT 40FMB User s Manual JY997D94201 JY992D09101 separat
9. en creation software ee eee SWOPC FXDU WIN E version 2 00 or later 1 1 Product Lists Production Name F940GOT SWD E Description Graphic operation terminal main unit SWD 8 colors LWD White and black Communication cable GOT lt CPU port in FXo FXos FX1s FXoNn FX1N FX2N or FX2Nc series PLC The connector on the GOT side is wired straight Cable length is 3m 9 10 Communication cable GOT lt gt CPU port in FXo FXos FX1S FXoN FX1N FX2N or FX2Nc series PLC The connector on the GOT side is wired straight Cable length is 3m 9 10 Communication cable GOT lt gt CPU port in FXo FXos FX1S FXoN FX1N FX2N or FX2Nc series PLC The connector on the GOT side is wired straight M is cable length 1M 1m 3 3 10M 10m 82 9 20M 20m 65 7 30M 30m 98 5 Communication cable GOT lt gt CPU port in FX FX2c A or QnA series PLC The connector on the GOT side is wired straight Cable length is 3m 9 10 Communication cable GOT lt gt CPU port in FX FX2c A or QnA series PLC The connector on the GOT side is wired straight M is cable length 10M 10m 32 9 20M 20m 65 7 30M 30m 98 5 Communication cable GOT lt gt CPU port in Q series PLC The connector on the GOT side is wired straight Cable length is 3m 9 10 F940GOT LWD E FX 50DU CABO FX 50DU CABO EN FX 50DU CABO M FX 40DU CAB FX 40DU CAB M QC30R2 FX 232CAB 1 PM 20BL FOGT 40PSC
10. ervice power supply of the programmable controller cannot be used e Even if instantaneous power interruption of less than 5 ms occurs the GOT continues to operate When power interruption for considerable period of time or voltage drop occurs the GOT stops its operation However when the power supply is recovered the GOT automatically restarts its operation The screen displayed just after recovery is determined by the working environment originally set 24V DC external power supply Grounding resistance 100Q or less class D Fuse 2A L24V DC PLC GOT 5 Expansion Module 6 Maintenance a F9OGT 40UMB The data transfer adaptor F9GT 40UMB is used to store the user screen data in the EPROM for user screen data FX EPROM 4M to the flush memory in the GOT The user screen data can be written to the EPROM using the screen design software This adaptor is useful when the same screen data is transferred to two or more GOT units For the operating procedure of F9GT 40UMB please see the manual of F9GT 40UMB b F9OGT 40FMB FOGT 40FMB has a built in flash memory and can transfer screen data when installed in the GOT When installed in OS versions either than 6 40 screen display is not available while transferring data from F9OGT 40FMB to the GOT For operating procedures and specifications refer to the manual
11. ing Temperature Humidity Vibration Resistance intermittent vibration Vibration Resistance Continuous vibration 2 2 Power Supply Specifications F94 GOT SWD E F94 GOT LWD E Power Supply Voltage Power Supply Ripple Current Consumption Fuse Fuse built in GOT impossible to change Max Allowable Momentary 5 ms If less than 5 ms the GOT will continue operation If 5 ms or Power Supply Failure period more the GOT will shut down Built in PM 20BL type lithium battery Approximately 5 years battery life Guaranteed term is 1 year 2 3 Screen Hardware Specifications F94 GOT SWD E F94 GOT LWD E STN colours liquid crystal 320 x 240 dot 40 characters x 15 lines 0 36 mm 0 014 Horizontal x 0 36 mm 0 014 Vertical 115 mm 4 53 x 86 mm 3 39 6 5 7 inch type Approximately 50 000 hours Operating temperature 25 C 77 F Guaranteed term is 1 year Backlight Cold cathode tube 40 000 hours or more Operating temperature 25 C 77 F Guaranteed term is 1 year Touch Keys Maximum 50 touch keys screen 20 x 12 matrix Display Device Resolution Dot Pitch Effective Display Size Number of Colours Life of liquid crystal Life of Backlight RS 422 Conforming to RS 422 Interface l RS 232C Conforming to RS 232C Nirmberorecreene User screen 500 screens or less System screen Allocated screens No 1001 1030 Flash memory 512 KB built in RS 422 for F940GOT OWD RS 232C for
12. n turns ON replace the battery PM 20BL as soon as possible The screen data is stored in the flash memory Even if the battery is totally worn out the screen data will remain even after severe battery voltage loss 6 1 1 Replacement Procedure PM 20BL 1 Turn off the power to the GOT and remove the battery holder cover waa SS 2 Remove the existing battery from the battery holder and disconnect 3 Within 30 seconds connect a new battery 4 Insert the new battery into the battery holder and attach the cover 6 2 Backlight Replacement Replace the backlight F9GT 40LTS using the following procedure Note Removing Rear Panel If the rear panel is pulled using an excessive force the cable connecting the rear panel and the front panel may be disconnected or the PCB may be damaged Be careful 6 2 1 Replacement procedure 1 Make sure that the power of the GOT is turned OFF Remove the mounting screws a located at 4 corners and slowly remove the rear panel 2 Disconnect the backlight connector b 3 Remove the backlight F9GT 40LTS c from the backlight fixing holder d It is recommended to insert a screwdriver into the holder Then the backlight can be taken out easily 4 Attach a new backlight F9GT 40LTS c Put it into the GOT by performing the steps 1 3 in the reverse order Manual number JY992D94201 Manual revision D March 2003 Date a MITSUBISHI ELECTRIC CORPOR
13. nsions mm inches MASS Weight 1 kg 2 2 Ibs Accessory Mounting brackets Tightening bolt M3 6 bolts Packing seal for dust and water resistance a 5 N VV 23 0 91 23 0 91 152 5 98 a Display b Mounting bracket hole c Communication ports Description RS 422 Port for connecting either a PLC including1 N connection or communication computer link unit lt 9 pin D sub gt RS 232C port for connecting eirher a personal computer printer bar code reader or 1 N connection lt 9 pin D sub gt RS 422 for F940GOT OWD RS 232C for F943GOT OWD PM 20BL battery DC power supply terminal M3 Packing seal d Mounting bracket and tightening bolt f Expansion interface g h Communication cable i 2 Specifications 2 1 General Specifications tem Specifications S 0 50 C 32 122 F With expansion module 0 40 C 32 104 F Storage Temperature 20 60 C 4 140 F Humidity 35 85 Relative Humidity No condensation 85 Relative Humidity No condensation Conforms to IEC 1131 2 10 57 Hz 0 075 mm Half Amplitude 57 150 Hz 9 8 m s Acceleration Sweep Count for X Y Z 10 times 80 min in each direction Conforms to IEC 1131 2 10 57 Hz 0 035 mm Half Amplitude 57 150 Hz 4 9 m s Acceleration Sweep Count for X Y Z 10 times 80 min in each direction 3 times in each direction X Y and Z Grounding resistance of 100 Q or less class D Operat
14. s necessary O Refer if necessary please Refer to the manual of the connected programmable controller for details concerning that unit 1 Introduction The F940GOT WD E hereafter called GOT or F940GOT is to be mounted on the face of a control panel or operations panel PLC and connected to the programming port CPU port or the communication port communication port of a PLC Various devices can be monitored and PLC data changed via the Programming GOT screens Several display screens are built in to the GOT port and additional personalized screens can be created by the user 1 The GOT can connect to MELSEC FX A QnA and Q PLCs as well as a host of third party manufactured units Further information can be found in GOT F900 Series Hardware Manual GOT 2 PLC user programs can be downloaded uploaded and monitored using programming software GX Developer or FX PCS WIN E on a personal computer via the GOT Further information can be found in the GOT F900 Series Operation Manual 3 Display screens are created using the following software Software Name GT Designer2 SWUID5C GTD2 E 0O indicates version Version GOT F900 and GOT A900 Series for Windows screen creation software GT Designer l l SWOID5C GOTR PACKE GOT F900 and GOT A900 Series for Windows screen creation software ae SW1 A edition of SW1D5C GOTR PACKE or later 0O indicates version GOT F900 Series for Windows scre

Download Pdf Manuals

image

Related Search

Related Contents

Origin Storage 1TB 2.5" NLSATA  DRYPOINT XCp Series [PDF 2 MB]  Finisar FTRJ1621S1MCL network transceiver module  TELSTRA T-BOX™  User Manual Invacare PreciseR ™ Pediatric Flowmeter  Vidikron 130 User's Manual  Page 1 Page 2 この取扱説明は、 セッ トメーカ様を対象に作成しており  Hélico Syma-S800G  Service Manual V1.0  Hamilton Beach 840141302 User's Manual  