CD295 - Campbell Scientific

image

Contents

1. Appendix A CD295 Door Kit Assembly Diagram Appendix B CD295 Mounting Template NOT TO SCALE REFER TO MOUNTING TEMPLATE SUPPLIED WITH CD295 L ALIGN TOP OF PAGE WITH TOP EDGE OF ENCLOSURE DataView Mounting Template Package Contents Package Contents CD295 DataView II Display CD294 DataView Display CD295 Programming Cable L CD294 Programming Cable CD295 Power cable Mounting Template Mounting Template _ 4 x screws washers nuts and rubber washers C 4 x screws washers nuts and rubber washers N A AN CUT OUT j WARNING It is highly recommended that the Stainless Steel Cover Plate is fitted to any installation where the DataView will be exposed to the elements especially UV Failure to do so may void warranty I Align the top of this mounting template with the top edge of the enclosure 2 Using a sharp marker scribe accurately mark the enclosure through the template at all 8 Points 3 Remove the template and draw lines to join the 4 inner points A B C and D This will indicating the section to be cut out 4 Remove the CUT OUT from the enclosure using the appropriate tools 5 Drill the 4 outer points 1 2 3 and 4 using a 4mm drill bit 6 Mount the DataView display and the Stainless Steel Cover Plate as per supplied diagram B 1 Appendix C Using Time Stamps At the time of release of this document the CRx000 series of dataloggers d
2. in a few but not all screens Explanation This message indicates that the DataView requested a public variable from the datalogger but has not yet received a response If some screens function correctly then the logger address 1s correct and the datalogger 1s answering requests correctly 19 DataView Il CD295 Dual Line Display Things to check Is this the right version of the DataView program for the datalogger program It 1s Important that the program that is running in the datalogger is the same as the one used when the DataView II program was written If not then the DataView II program may need to be re written e Symptom After sending a program to the DataView Il it displays No program and won t show any of my screens Explanation The No program message indicates that the current program in the DataView II is incomplete or incorrect No permanent harm is done by sending an incorrect file however it will not execute Things to check Did you download the correct file It is very important that you select the DV2 file that you created with PC295 and not the 295 file which is only created for internal use by the PC295 software itself or any other file on your computer Try downloading again Could your DV2 file be corrupt No software other than PC295 should be used to edit DV2 files Even a slight change to the file is enough to cause the CD295 to reject the program Try recreati
3. 0121 0 11 6 PA Po po O 11 4 2 1 1 Establishing a Connection 11 4 2 1 2 Downloading a PrograM oooooonnnncnnnnnnnnonononononnnnnnncnnnnnonononononnnnns 12 AD RA EEE e e p n e bi 13 4 2 1 4 Upgrading the Operating System OS eeeeeeooooooooooononenooon 14 5 Mounting in Enclosure Door 16 6 SRIPPINOIME race 17 Le REC UC alcalina 18 8 Problem S io 19 9 Temperature Extremes and LCD Adjustment 20 Appendices A CD295 Door Kit Assembly Diagram B CD295 Mounting Template C Using Time Stamps DataView II CD295 Dual Line Display 1 Introduction NOTE The DataView II is a two line 32 character LCD that displays real time values from a CR2xx series datalogger along with a pre defined description string and units string Two buttons allow the user to scroll through the programmed locations that are updated as often as they are measured When the user has not pressed a button within a user defined period default 120 seconds the DataView II switches to low power mode drawing a current of less than 1mA The DataView II is easily configured using the Windows based PC295W and DevConfig packages Throughout this document the terms DataView II CD295 and DataView2 are used interchangeably 1 1 Changes from Version 1 to Version 2 The original release of the CD295 operating system
4. Apply a thin coating of neutral cure silicon sealant between the flange of the CD295 and enclosure door Use the screws and nuts provided to attach the CD295 Insert the head of the screw followed by a flat washer through the front of the CD295 On the inside of the enclosure fit the rubber o ring washer then the second flat washer followed by the dome nut If fitted remove the nut bolt and washers from the top left mounting hole of the CD295 front panel Remove the nylock nut stainless steel and rubber washers from the bolt assembly fixed to the CD295 door At this point the Bolt assembly holding tag should be exposed Insert the bolt assembly through the top left mounting hole of the CD295 front panel From the inside of the enclosure fit the rubber washer stainless steel washer and nylock nut onto the stainless steel bolt assembly After confirming that all hardware has been fitted in the correct order tear off the Bolt Assembly Holding Tag 10 Tighten the nylock nut until the black rubber washer is tightly compressed NOTE 6 Shipping Kit User Manual If you are fitting the CD295 door kit only 3 bolts are required to be fitted at this step The bolt in the top left corner of the CD295 front panel is not required In this case only fit the remaining three bolts and use the longer 30 mm bolt supplied in the door kit in the top left hole Do not over tighten as this will cause damage to ru
5. displap Mir onese Bookean Yansbie Display Dpiian 7 OTF Description 040 ToelFalre limas 11 0 Decemal Maces Long integer data types are used to store both integer whole numbers and time stamps Choose Numeric for the Display Option if your long integer variable is a whole number Several display options are offered for time stamps see below AOS Heridas 20 Dis tito Screen Hume Li Auk Seren Dette Screen Long Vanisble Display Options C Humanc Value DI NICH Ma FileName beet EMI MIMO MEA Dataview 3 Malrach Main 1 sconta C MMMH IMMM SS HDD IEAM So Maitabla to dieplop DIC 2 sel DecenaiPizces Bocte an Vaneble Display Options The date stamp will only show meaningful values if the long integers are created correctly For more information refer to Appendix C 7 If at any time you would like to return to an earlier screen you can do so by using the Screen Number drop down Also if you would like to delete a screen you can select the screen you would like to delete from the Screen Number drop down and click the Delete Screen button User Manual After entering all of the screens in your DataView II program you will probably want to save your work Click File gt Save As and this will open a dialog in which you can specify a filename and save your DataView II program If you are modifying an existing program or have already saved you
6. on request It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment in support of this policy a Declaration of Hazardous Material and Decontamination form will be issued for completion When returning equipment the Repair Reference Number must be clearly marked on the outside of the package Complete the Declaration of Hazardous Material and Decontamination form and ensure a completed copy is returned with your goods Please note your Repair may not be processed if you do not include a copy of this form and Campbell Scientific Ltd reserves the right to return goods at the customers expense Note that goods sent air freight are subject to Customs clearance fees which Campbell Scientific will charge to customers In many cases these charges are greater than the cost of the repair CAMPBELL SCIENTIFIC EUROPE WHEN MEASUREMENTS MATTER Campbell Scientific Ltd Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UK Tel 44 0 1509 601141 Fax 44 0 1509 601091 Email support campbellsci co uk www campbellsci co uk PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc primarily for the North American market Some spellings weights and measures may reflect this origin Some useful conversion factors Area 1 in square inch 645 mm Mass l oz ounce 28 35 g 1 l
7. that you close any applications you may be running Exit Setup 3 The next screen asks where you would like PC295 installed on your hard disk If you wish to install into a path other than the default click Change Directory and use the windows dialog to choose a suitable location Once the path 1s correct click the Install icon in the top left corner of the window 2 PC295 Setup 3 x Begin the installation by clicking the button below Click this button to install PC295 software to the specified destination i directory Directory C Program FilesiPC295 Change Directory Exit Setup DataView Il CD295 Dual Line Display 4 The next dialog to appear asks which program group on the start menu you would like to add PC295 The default is usually acceptable however if not you are free to choose your preferred program group in this step Click Continue e PC295 Choose Program Group 1 x Setup will add items to the group shown in the Program Group box You can enter a new group name or select one from the Existing Groups list Program Group i g 5 Existing Groups Accessories Administrative Tools Eridge Builder PLZIHN wl Z Z PEFO7 v2 0 Quote Manager Quote Writer SmartDraw Startup once 5 File copying will now begin 2 PC295 Setup q x Destination File Ci Program Files PC2951test 295 6 Once the Setup is comp
8. the products life should be removed from the product and also be sent to an appropriate recycling facility a 3 Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases asa arrange collection and the correct disposal of it although charges may apply for some items or territories For further advice or support please contact Campbell Scientific Ltd or your local agent CAMPBELL SCIENTIFIC EUROPE WHEN MEASUREMENTS MATTER Campbell S cientific Ltd Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UK Tel 44 0 1509 601141 Fax 44 0 1509 601091 E mail support campbellsci co uk www campbellsci co uk Contents PDF viewers note These page numbers refer to the printed version of this document Use the Adobe Acrobat bookmarks tab for links to specific sections i INroguetion a sr a 1 1 1 Changes from Version 1 to Version 2 i l li 2 Normal Opera om Overy Wi l 2 Installation Procedure nennen 2 Ji SOMWA O ici 3 3 1 Computer System Requirements oooonncnnccnnnnncncccnononnnnnnnnnnnnnnnnnnnnnnnnononnnnnos 3 3 1 1 Minimum Configuration 3 3 1 2 Recommended Configuration i 3 3 2 Soll ware AAA ko a ke a a a aa kr poo aa 3 A Programming aaa 4 DIP rile 4 Al Oper ON ae ua ka 5 4 12 Online FAC IP ti lea 10 4 2 Device Configuration DEVCONFIG rr 11 42 GE
9. DataView Il CD295 Dual Line Display User Manual Issued 1 11 10 Copyright 2005 2010 Campbell Scientific Inc Printed under licence by Campbell Scientific Ltd CSL 572 Guarantee This equipment is guaranteed against defects in materials and workmanship This guarantee applies for twelve months from date of delivery We will repair or replace products which prove to be defective during the guarantee period provided they are returned to us prepaid The guarantee will not apply to e Equipment which has been modified or altered in any way without the written permission of Campbell Scientific e Batteries e Any product which has been subjected to misuse neglect acts of God or damage in transit Campbell Scientific will return guaranteed equipment by surface carrier prepaid Campbell Scientific will not reimburse the claimant for costs incurred in removing and or reinstalling equipment This guarantee and the Company s obligation thereunder 1s in lieu of all other guarantees expressed or implied including those of suitability and fitness for a particular purpose Campbell Scientific s not liable for consequential damage Please inform us before returning equipment and obtain a Repair Reference Number whether the repair is under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period 1t should be accompanied by a purchase order Quotations for repairs can be given
10. V1 0 and PC295 V1 0 supported the CR200 series dataloggers only Version 2 of the CD295 operating system and PC295 added support for our CR1000 CR800 CR850 and CR3000 dataloggers as well as support for their new data types long integers Booleans strings and time stamps To use the new capabilities both the CD295 operating system OS and PC295 software needs to be upgraded to Version 2 Refer to Section 4 2 1 4 to upgrade the CD295 OS To upgrade PC295 uninstall previous software versions and then follow the procedure provided in Section 3 2 1 2 Normal Operation Overview Below is a general description of normal operation of the DataView II CD295 When first powered up the DataView II displays the following greeting Campbell SCIENCLFLE and the backlight will be lit After a program has been successfully downloaded the CD295 is configured and connected to the datalogger it is ready for general use Pressing one of the buttons on the CD295 will cause the LCD to display something like the example below DataView Il CD295 Dual Line Display geen Description Temperature Pras 14 294 deg Fe Value Units The top line contains a string referred to as the Description and the second line contains both the value retrieved from a Public Variable in the datalogger and a string referred to as Units The value displayed on the second line can be displayed with a user selectable number of decimal places Tog
11. a DataView II program is to select Create new DataView2 Program from the File menu This will open a file browser window which will allow you to locate the datalogger program with CRI CR2 CR3 or CR8 extension When the correct datalogger program is selected click Open If you already have created a DataView II program that you wish to edit select Open Existing DataView2 Program in the File Menu A file browse window will appear Locate your DataView II program 295 extension and click Open DataView Il CD295 Dual Line Display p ausw ihik a PAT A mn ya pio ETP 4 Ifyou have chosen to Create a new DataView2 program a file browse window will appear To operate correctly your DataView II needs some information about the program running in the datalogger to which 1t will be connected PC295 reads the datalogger program file you select at this step and extracts information such as the Scan Interval and the list of Public variable names Locate the datalogger program and select Open prectxisting da tinta informatica fie EEE T AEN 5 5 User Manual PC295 will now return to the main screen however the CRX FileName and DataView 2 Refresh Rate will no longer be blank PC295 has read your datalogger program and is now ready for you to create a DataView II program Select the Add Screen button Variable to Display has a drop down list from whi
12. b pound weight 0 454 kg Length 1 in inch 25 4 mm 1 ft foot 304 8 mm Pressure 1 psi Ib in 68 95 mb 1 yard 0 914 m 1 mile 1 609 km Volume 1 UK pint 568 3 ml 1 UK gallon 4 546 litres 1 US gallon 3 785 litres In addition while most of the information in the manual is correct for all countries certain information 1s specific to the North American market and so may not be applicable to European users Differences include the U S standard external power supply details where some information for example the AC transformer input voltage will not be applicable for British European use Please note however that when a power supply adapter is ordered it will be suitable for use in your country Reference to some radio transmitters digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some cases alternatives are offered Details of the alternatives will be covered in separate manuals Part numbers prefixed with a symbol are special order parts for use with non EU variants or for special installations Please quote the full part number with the when ordering Recycling information At the end of this product s life it should not be put in commercial or domestic refuse but sent for recycling Any batteries contained within the product or used during
13. bber washer See Appendix A for the assembly diagram for the CD293 door kit The CD295 DataView II Shipping Kit includes e CD295 DataView II display e CD295 programming cable e PC295 software on CD e CD295 Manual e CD295 Mounting Template e 4x stainless steel mounting screws dome nuts stainless steel and rubber washers If the CD295 is to be mounted in the front door of an enclosure the CD295 door kit will also be included This kit includes e CD295 stainless steel door e stainless steel screw with nylon spacer PTFE rubber and stainless steel washers and nylock nut e CD295 door mounting diagram 17 DataView Il CD295 Dual Line Display 7 Hardware 18 SPECIFICATIONS Physical Width 130 mm Height 100 mm Depth 30 mm Weight 235 g Power Supply 8 16 Vdc 12 V nominal Power Consumption at 12 Vdc Active with backlight 30 mA Active without backlight 3 mA Asleep 1 mA Communications Physical protocol RS232 DTE Network protocol PakBus Configuration protocol DevConfig Environmental Temperature Operating 20 C to 55 C Asleep 25 C to 70 C Humidity IP65 when mounted in enclosure door with supplied sealant General No of screens 30 max Value update interval 1 65535 sec Backlight period 0 60 secs default 10 Power down period 5 254 secs default 120 255 never sleep CD295 address 1 4094 default 4090 Logger address 1 4094 defaul
14. ch you are able to choose a Public Variable used in the datalogger program IPC Versen 20 Die tito Soren Mumbe 1 diaman Detto Seren Long Variable Dinples Options Aa FileName kari DI DataVian 2 Melrach Main 1 seconda Bonen Yansbie Display Uptiona The Description and Units fields are free form text strings that are displayed on the CD295 along with the value collected from the datalogger These fields can be used to provide a user friendly description and engineering units of the value displayed It is also possible to choose the number of decimal places to be used when displaying the value Complete the Description Units and Decimal places APC Verein 20 Dis ee Soren Humbe disc ekte Geco Long Variable Display Options Ma FileName tect ENI Deia 2 Matrach Mato 1 acond LI u i Bonen Yansbie Display Dpiian You can now continue adding screens by repeating steps 5 and 6 as many times as necessary DataView Il CD295 Dual Line Display NOTE If the variable you have chosen is not floating point the Display Options panes on the right side of the screen will provide multiple options for displaying the variable The example below shows the Display Options for a Boolean variable PC Verse 10 Ei ee Sermon Humbe e disco Peteco Long Vanse Display Options Aa FileName tect CAN Mainin Metrach Main 1 recondita Vasiablo to
15. e window 13 DataView Il CD295 Dual Line Display 14 2 After all changes are complete Click Apply to send the new settings to the DataView II After the settings are applied DevConfig will show the new values of the Settings from the CD295 ETSI Device Configuration Utility B Dinvico Type Program Control Send 05 Settings Ector k sion COA Address Lope Address I Lose Security Code Q Powe Doen Time 120 Se al Murer 1045 Eset Time if Version Gerin Port This is the Operating System Wersion Huber This field is read only ah date Eockoy Dito Bird Files Dany 3 If after editing a setting you wish to discard the changes Click Cancel DevConfig will show the current values of the settings in order for you to verify that the changes were discarded 4 Itis possible to return the DataView II to its factory default settings To do this Click Factory Defaults 4 2 1 4 Upgrading the Operating System OS NOTE From time to time new operating system s for the DataView II may be released to correct errors in the operating system or to add new functionality To take advantage of this it is necessary to send the new operating system OS to the DataView II 1 If you need to send a Operating System to your DataView2 open the Send OS tab in Device Configuration and select the Send OS button at the bottom of the window It is not necessary t
16. ellsci com Campbell Scientific Africa Pty Ltd CSAf PO Box 2450 Somerset West 7129 SOUTH AFRICA www csafrica co za e sales csafrica co za Campbell Scientific Australia Pty Ltd CSA PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www campbellsci com au e info campbellsci com au Campbell Scientific do Brazil Ltda CSB Rua Luisa Crapsi Orsi 15 Butant CEP 005543 000 S o Paulo SP BRAZIL www campbellsci com br e suporte Ocampbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca e dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc e info campbellsci cc Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk e sales campbellsci co uk Campbell Scientific Ltd France 3 Avenue de la Division Leclerc 92160 ANTONY FRANCE www campbellsci fr e info campbellsci fr Campbell Scientific Spain S L Avda Pompeu Fabra 7 9 Local 1 08024 BARCELONA SPAIN www campbellsci es e info campbellsci es Campbell Scientific Ltd Germany Fahrenheitstrasse13 D 28359 Bremen GERMANY www campbellsci de e info campbellsci de Please visit www campbellsci com to obtain contact information for your local US or International representative
17. end OS Settings Editor Logget Program Last Compie 06721705 14 07 40 Device Type Laut Comple Rests A file browser window will appear Locate the DV2 file you wish to download and Click Open NOTE User Manual When a DataView II program is created PC295 creates two files the DV2 file for download to your DataView II and a 295 file which contains internal configuration information for the PC295 program You should only send the DV2 file to your CD295 Look in la Dataview 2 vi o 2 egan Fe Dataview DYZ My Recent Documents Desktop My Documents sE My Computer MI File name v LW Va Files of type Program Files dw2 _ Cancel Places TT Open as read only 3 DevConfig will download your program to the DataView II and return to Program Control PCS Device Configuration Utility Program Control Send 05 Steigen Editor Program Send Bistum fa Care Program io sera a ram program 4 2 1 3 Modifying Settings NOTE 1 The Settings Editor tab allows you to read modify any device specific settings in the CD295 To change a setting double click the settings you wish to change and type the new value Repeat for as many settings as necessary Some settings are read only and others have limits on the range of acceptable values A description along with the maximum and minimum values appears in the comments box at the bottom of th
18. ether the combination of Description Public Variable Units and number of decimal places is referred to as a screen The CD295 is capable of holding and displaying up to 30 screens There are no limitations on the order of screens or which Public Variables are displayed Pressing the buttons on the front panel of the DataView II will cause the next or previous screen to be displayed The CD295 will attempt to collect anew value from the datalogger under the following conditions e The user has changed screen e The scan interval of the datalogger has expired After some time default 10 secs the backlight will turn off however the text will remain visible until the unit enters sleep mode default 120 secs Whenever one of the buttons on the front panel is pressed these two timers Backlight timer and Power Down timer are both reset As a result the DataView II can be woken from sleep mode by pressing either of the buttons While in sleep mode the DataView II will continue to respond to PakBus communications however the LCD is turned off and no requests are sent to the datalogger 2 Installation Procedure Below is a general guide to the steps involved in configuring and programming a DataView Il CD295 1 Using the CD from the CD295 shipping kit install PC295W and DevConfig on your computer 2 Connect the programming cable s 9 pin D connector into the CD295 data cable and the other end in
19. lete the following window is displayed You are now ready to start using PC295 Click OK PC295 Setup W x PC295 Setup was completed successfully 4 Programming 4 1 PC295 PC295 software is a freeware utility provided by Campbell Scientific Australia to write programs for the DataView II PC295 first reads the datalogger program to generate the list of Public Variables and to determine the scan rate of the datalogger Once this information has been determined the user is able to choose a public variable to display and can associate Description and Units strings with it to form a screen A group of 4 1 1 Operation User Manual screens forms a user program and PC295 saves this program to disk in a DV2 file By default the first part of the filename is the same as the datalogger program from which it was generated So for example if you opened station cr2 to create the DataView II program PC295 would save the program as stationl dv2 This naming convention is strongly recommended but not mandatory 1 To start PC295 Click Start gt Programs gt PC295W DataView2 Programming Software gt PC295W DataView2 Programming Software 2 Once the PC295 program starts you will see the main screen APC Verse 20 Dio tito Ennan Muses da Long Yoriable Display Options Ma Fa kana iman Melrech Main Wauisbin ta dinplap Bootean Yaneble Display Options 3 The first step in creating
20. nect button 11 DataView Il CD295 Dual Line Display 2091 Device Configuration Ley File Hele Deven Type CD295 In order to configure the COZ power must be supplied to Ihe COSS 12 Walls DC via the power cable provided Connect the COSSS sanal cable to the computer serial port When these raquiramente have bean mat select the appropriate senal port in ihe left panel and press ihe Connect button E CIS Designed and Manufadiunid by Campbell Scient Australia ef wee Campbellsci corn au DevConfig will automatically detect the connection speed and PakBus address of the DataView II Once detection is complete 3 tabs should appear in the window on the right hand side These are Program Control Send OS and Settings Editor The Program Control tab is used to send a program to the DataView II and is the most commonly used of the three tabs As the name suggests the Send OS tab is used to send an Operating System OS to the DataView II This is used to upgrade the firmware of the CD295 The Settings Editor tab is used to read modify the addresses and timers mentioned above 4 2 1 2 Downloading a Program l 12 To download a program ensure that you are already connected to the CD295 and the Program Control tab is selected Click the Send Program button CSI Device Configuration Utility 2101 x Program Control S
21. ng the DV2 file in PC295 and download it again 9 Temperature Extremes and LCD Adjustment 20 The CD295 has been tested to 20 C It will perform at this temperature although the display may be sluggish and dim Under temperature extremes the CD295 s liquid crystal display LCD may become difficult to read LCD contrast can be adjusted by inserting a small jeweller s screwdriver preferably plastic into the round hole on the back of the CD295 cover and adjusting the LCD contrast potentiometer anoqe suononu su sad se ajejd JSAOD 9913 ssajuie s Uy MAlAV LYG YO 109 Gununonw 1437 dOL nowe suonejjejsum Gunsixe UN Jaysem Buyeag saqqny 0 abewep asnes m siy se uajybruaao zou og pessesdwoo WI Si oysem Y398NY NOLIE VEUL OS INN MOOTAN ves MIA HITS 0 paseype aq jsnw syed jo Japio 3 LON weu e p sad se ajqwassy SNOILLINALSNI Thy Y3IVAS VOJ N SHYM Wup uo N YIHSVM 199qNy 498 98 JUO L SYIHSVM SSajule15 JUO Z SY3HSYM NOT3JL BUM O Z N INN MOOTAN AUO L 1708 papeauul ssajules wwog AYO L 3LYTd YZAOD SSajule S uo L LIM SNILNNOWN 31W1d 30V MAUAWLIVO ousem SISUSEM s6u y62 GI leas Y3AANY SSIINIVIS P Y yj 43109 13318 SS3INIVIS j Fall y ACU CH i ANANN Aa an Wa SONYA OT v q s ausem JOUSEM NO 1431 IMUM 1295 HIGANY Jededs NOTAN Willy AN 3UNSOTON3 LNSWNYLSNI
22. o Connect using DevConfig to send an operating system CAUTION User Manual 2 A file browser window will appear Locate the operating system file A43 extension provided by your supplier and Click Open 3 After selecting the operating system file 1t will be necessary to power cycle the DataView II Disconnect the power from the CD295 and reconnect it 4 The download will begin and progress bar should begin to fill It is VERY important that the power cable and programming cable remain connected while the download is underway Failure to do so may cause permanent damage to the CD295 15 DataView Il CD295 Dual Line Display 5 6 When the download is complete DevConfig will display a popup to confirm the success or to notify 1f there was an error 05 Send Complete x The 05 C cd295_1 00 a43 has been sent to the CD295 Its signature is 43650 Oxaa82 Once the download is complete disconnect power from the CD295 for at least 30 seconds to ensure that it has been completely reset After this the new operating system will run 5 Mounting in Enclosure Door If the DataView II will be exposed to the elements it is important to fit the CD295 door kit as explained below 16 l Use the template provided to mark out the four mounting holes and cut out for the CD295 Drill the four corner holes using a 4 5mm drill and cut out the mounting hole using ajig saw or nibbler
23. o not support variables of a date type Dates are currently recorded in a long integer as the number of seconds that have elapsed since 1 1 1990 00 00 00 The DataView II is capable of displaying these values in Gregorian Date format 1 e Day Month Y ear etc in a number of different representations Below is an example CR1000 program to record a timestamp for display on a CD295 Public Time as Long BeginProg Scar dl Sec 07 0 Time Public TimeStamp 1 1 Nextscan EndProg In this case when creating the DataView program in PC295 for this variable the user should select one of the date representations instead of Numeric Value as per the screenshot below T PC295W Version 2 0 ll ioj xj File Help Screen Number 2 Add Screen Delete Screen Long Variable Display Options Numeric Value i DD MMAYrt HH MM CRx FileName test ER1 CC MM DDANYYY HH MM C DD MM HH HH 55 C MM DD HH HH 55 DataYiew 2 Refresh Rate 1 second s Yarable to display public ts Description Timestamp Boolean Yanable Display Options In this case the DataView II would display the time as below Timestamp 24 01 2007 9 34 Please Note If this value is displayed using Numeric Value the DataView II would show something like this Timestamp 538479240 C 1 CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific Inc CSI 815 West 1800 North Logan Utah 84321 UNITED STATES www campbellsci com e info campb
24. r work you can select the Save option which will not prompt for a new filename DataView Il CD295 Dual Line Display 10 NOTE 4 1 2 Online Help Save DataYiew2 file to disk Save in E Dataview 2 de t My Recent Documents Desktop S My Documents I er My Computer Mi File name Dataview 233 LTW ki Network Save as type 235 Files 5 295 Cancel F aces Zi 9 Once you have completed and saved the DataView II program you are ready to download the program into the DataView II itself To do this you must have the Device Configuration utility installed on your computer Please ensure that it is installed before proceeding To continue with programming the DataView I CD295 please refer to Section 4 2 Device Configuration From within PC295 Device Configuration can be started through the file menu Click File gt Program a DataView2 with a DV2 file EOE alla Pil Pp Crame a Mer Dara program Long Manable Display Upton Tp ari mn tra Dia rin aa an o Numero Value Rosa ari Cameri a Cabe I prograre ened vi amp DD MEA HH MA aa THEY HH MW I U Z DDAN rit W55 PC295 has two items on the Help menu PC295 and About About lists the version number of the PC295 software and PC295 contains online help to guide you through operation of the software It is a simple step by step guide to writing your Da
25. t 1 Description string 16 chars max Units string 8 chars max Decimals O 6 digits after decimal 8 Problems User Manual Symptom The DataView II displays Waiting in every location Explanation This message indicates that the DataView requested a public variable from the datalogger but has not yet received a response Things to check Is the DataView II connected to the datalogger Check the serial cable from the DataView II to the datalogger Does the datalogger have power Check the power supply to the datalogger Does the PakBus address of the datalogger match the Logger Address in the CD295 Using DevConfig check that the Logger Address setting in the DataView II and the PakBus address of the datalogger match refer to your datalogger manual Is the baud rate of the datalogger s RS 232 port set to 9600 or auto By default the datalogger s serial port speed should be suitable for the CD295 If it has been manually changed it may need to be adjusted Is this the right version of the DataView program for the datalogger program It is important that the program that is running in the datalogger is the same as the one used when the DataView II program was written If not then the DataView II program may need to be re written Could the datalogger be too busy to answer Consider the execution of the datalogger program and modify if necessary Symptom The DataView II displays Waiting
26. taView II program User Manual 4 2 Device Configuration DEVCONFIG Device Configuration DevConfig is a freeware utility provided by Campbell Scientific for the configuration of PakBus devices This tool allows the user to send programs upgrade firmware in the device and modify device settings In the case of the CD295 DevConfig allows you to download your program and read modify the following settings Version the operating system version number CD295 Address the PakBus address of the DataView II Logger address the PakBus address of the datalogger from which the CD295 should collect values Logger Security Code the security of the datalogger this should always be O for the CR200 Power Down Timer the period of time after which the CD295 should return to sleep mode Serial Number the serial number of the DataView Backlight Timer the period of time to keep the backlight on Before using DevConfig it is important to provide power to your DataView II CD295 and connect the serial port of your computer to the CD295 using the programming cable provided see figure below fj CAMPBELL pr SCIENTIFIC Ey DataViaw Ni e ko ip kopi E la a 4 2 1 Operation 4 2 1 1 Establishing a Connection 1 Start the Device Configuration utility 2 Select CD295 from the Device Type on the left hand side of the window Verify the Serial Port in the bottom left of the window is correct and Click the Con
27. to your PC s serial COM port 3 Using PC295W and the datalogger program configure your screens of your DataView II DV2 file 4 Using DevConfig send the DataView II program DV2 file and change any settings e g PakBus Address Remove the programming cable Mount the CD295 into your datalogger enclosure Connect the CD295 data cable to the datalogger s RS 232 port YE DW D SA Power up the datalogger and CD295 and verify correct operation User Manual 3 Software 3 1 Computer System Requirements 3 1 1 Minimum Configuration PENTIUM class machine with 64 MB RAM running Windows 98 3 1 2 Recommended Configuration PENTIUM class machine with 128 MB RAM running Windows 2000 XP 3 2 Software Installation 1 To begin the installation of the PC295 software insert the PC295 CD into your computer and locate and open the setup exe file which contains the software to be used Help ci Dre S EX 35 x Size Type DateModfied O m 1 895 KB Winzip File 27 06 2005 2 30 PM 138KB Application 18 06 1998 12 00 AM SKB LST File 27 06 2005 2 30 PM Type Application Size 137 KB 2 After starting Setup exe you will be presented with a welcome screen giving a brief introduction to the software Click OK 2 PC295 Setup i x A Welcome to the PC295 installation program de Setup cannot install system files or update shared files if they are in use Before proceeding we recommend