        User Manual M-WRG-S _28-3-2011
         Contents
1.     D 82239 Alling     info meltem com     www meltem com      10            Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG       Deckeldrehpunkte    MIT UNS L  FTEN SIE RICHTIG    Meltem    L  FTUNG  amp  WARMER  CKGEWINNUNG       5  Trouble shooting    Problem Reason    M WRG S ventilation unit does   Installation error Let a certified electrician test the  not work connecting wires    M WRG S ventilation unit does   Power switch  motor or Let a certified electrician test the  not work main control is are defective ventilation unit    Air flaps do not open once the If the M WRG S ventilation unit   The M WRG S ventilation unit  M WRG S ventilation unit is is not operated for a longer should be switched ON and OFF  switched ON period of time or operated for the   again by the operator   first time  the motor may not   receive power    Air flaps do not open once the Air flaps may be clogged  e g  Hemove any clogging material   unit is switched ON dirt  polystyrene  plaster  etc   remove cover to do so see User  Manual section filter  replacement     M WRG S ventilation unit starts   The M WRG S ventilation unit Replace the filters  see User  to beep in intervals signals a soon to be done filter   Manual  section filter  replacement replacement        6  Antifreeze Protection    The M WRG S ventilation unit is equipped with an antifreeze protection  In case of very low exterior  temperatures  the M WRG S ventilation unit will automatically start up the anti freeze protection mo
2.  CKGEWINNUNG       e Never cover the M WRG S ventilation unit or any  part of it with e g  cabinets  blinds or curtains  A  minimum distance of 30 cm to any furniture is  required  in order for the M WRG S ventilation  unit to remain fully operable     The M WRG S ventilation unit has been  designed for continuous operation and a long  lifespan  During cold seasons  the M WRG S  ventilation unit should be operated continuously   High efficient DC motors and innovative  electronics ensure a very low power consumption  of approx  3 8 Watt at ventilation rate    Only a  continuous operation achieves a permanent  extraction of moisture and condensation  If this  does not occur  it is possible that condensate will  gather in the unit     e  f a high concentration of moisture occurs  we  recommend to regularly ventilating the room at  the highest ventilation level for 10 minutes  in  order to eliminate any possible condensation  inside the unit     e  n order to guarantee a smooth operation   especially during low exterior temperatures   below  5      you should avoid interior  temperatures below 15        Caution  In case of exterior temperatures below  OC  icicles may form at the facade covers   These should be removed for safety purposes     Filter replacement    The ventilation unit automatically monitors the filter  status  An acoustic warning signal will inform you   when the filters need to be replaced     However  for hygienic reasons  it is strongly  recommended to replace
3.  the filters at least once  per year  ideally before the heating season     For a reliable operation of the units and for your  own safety  only original and certified parts  from Meltem shall be used  Otherwise this may  void the warranty and Meltem will not be liable  for any damages     We hope you will enjoy your new M WRG home  ventilation system with heat recovery     MIT UNS L  FTEN SIE RICHTIG    Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG    Contents  1  YOU have made th   potter  4   MEE AN CUNY E  4   1 2        does the M WRG S ventilation unit work Ve  5   13  M WRG S ventilation unit Ovenlew   6   2  Stari up                               deme ER                  7    3  Fiter                    Ke                                                 8   3 1 mz COM ct ave tc m E TU xm  8   3 2 Replacement of Filters                                             8                  LMM COV                       Pos acd nie              8    9322           old    E   9    9 283           ci FIEIS               9    324  PACK ON COV SM                        E   10    4  Cleaning the M WRG S ventilation unit                       00000000000nnnnnnnnnnnnnnnnnnnnnnn nen nnnn nn nun nnnnnnnnnnnnnnnnnnnnnn   10    5  Trouble SNOG O      ee E ol   11    6                     PFOLECHON                                              11    7 Technical                                                                            12    Meltem Warmeriickgewinnung GmbH  amp             M
4. IT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info meltem com     www meltem com    3  E      Meltem    L  FTUNG  amp  WARMER  CKGEWINNUNG       1  You have made the right choice     With the M WRG S decentralized ventilation unit with heat recovery  you acquired a high quality product   M WRG S stands for Meltem     heat recovery     with comfort  Meltem s    know how    of more than 30 years  developing and producing decentralized ventilation systems is now combined with their innovate heat recovery  process    Ventilation by opening windows especially during cold seasons  belong to the past  From now on  fresh and  filtered air is supplied fully automated  The stale air is extracted from your home and while passing through the  heat exchanger its warmth is transferred to the fresh air  While doing so  the M WRG units have a minimum  power consumption  You save heating costs  increase the comfort of your home and at the same time reduce  the impact on the environment by reducing CO2 emissions    The system is constructed for continuous operation  We guarantee an effective operation as well as a long  lifespan of the system if it is correctly used  We hope you will enjoy your new M WRG home ventilation system  with heat recovery     1 1 Safety and Security    e The M WRG S ventilation unit may only be operated once installed correctly   e For correct installation of the system please follow the instructions of the assembly manual     e The M WRG S ventil
5. Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG    HOME VENTILATION WITH HEAT RECOVERY       Ventilation Unit M WRG S                    e       L     1 ben           e        USER MANUAL    Best Nr  5302 00 01 03 2011  Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info meltem com     www meltem com       Important user information    Ventilation with heat recovery    M WRG S is a decentralized ventilation system with  heat recovery from Meltem  It adds to the value of  your home and creates a healthier indoor climate   and is a protective measure against moisture and  mold damages in your home    Ventilation by opening windows especially during  cold seasons  belong to the past  From now on   fresh and filtered air is supplied fully automated   The stale air is extracted from your home and while  passing through the heat exchanger its warmth is  transferred to the fresh air  While doing so  the M   WRG S ventilation units have minimum power  consumption  You save heating costs  increase the  comfort of your home and at the same time reduce  the impact on the environment by reducing CO2  emissions    Of course you still may open your windows    especially during warmer days     A family of four produces daily an average of 10 14  litres of moisture  due to cooking  laundry  personal  hygiene  and breathing of inhabitants  plants and  animals  This excessive amount of moisture  within  the interior air  is extra
6. ation unit may only be used for the ventilation of living space and interior rooms   Kitchens  bathrooms  basements  offices  etc   With rooms that have an excessive build up of dust and  corrosive gas emissions  the M WRG S ventilation unit may be limited and or damaged in its operating  capacity     e Please familiarize yourself with the operating modes and procedures of the M WRG S ventilation unit     e The M WRG S ventilation unit is especially suitable for the drying phase after the building is constructed  and the inhabitants have moved in  It is not suitable for drying a building during construction or to  ventilate a building while interior renovations are in progress  A continuously high concentration of dust  and or moisture will clog the filters additionally and overwork the automated extraction of condensate     e Never operate the M WRG S ventilation unit without the suitable filters  The filters protect your health  and your living space from exterior environmental influences  Only with the suitable filters  the M WRG S  ventilation unit will remain clean  Additionally it will prevent the pollution of the electrical components and  the heat converter  as well as reduce or prevent full operating capacity of the M WRG S ventilation unit     e Do not install the M WRG S ventilation unit into the interior of a cabinet or other furniture  Do not cover  the M WRG S ventilation unit with a any type of fabric  towel  curtains  etc   or any other objects   furniture  bl
7. cted through the M WRG  ventilation unit and therefore prevents the forming  of mold and resulting building damages  At the  same time  fumes from floors  furniture and a too  high CO2 concentration in the air  which can lead to  fatigue and health issues  will be extracted from the  interior rooms and replaced by fresh and clean air     Directions for correct usage    Please read this manual carefully and follow the  instructions contained in this manual  Familiarize  yourself with the M WRG S ventilation unit  and pay  attention to the warnings and cautions contained in  this manual     e Never operate the M WRG S ventilation unit  without filters  Only with the original filters from  Meltem  the units will remain clean  fully  operative  and have a long lifespan     e The M WRG S ventilation unit may only be  operated once installed correctly     e When ventilating basements or similar rooms we  advise to be cautious  especially during the  summer season and warm weather   due to the  fact that the moisture in the air will condense on  cold interior walls and   despite ventilation      moisture damages can occur  Therefore only  ventilate at night during warm weather seasons  If  you would like to ventilate such rooms with a M   WRG ventilation system  please consult with the  manufacturer prior to purchase     Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG  Am Hartholz 4     D 82239 Alling     info pmeltem com     www meltem com     2     Meillet    L  FTUNG  amp  W  RMER 
8. de  Due to  these reasons we advise not to turn the M WRG S ventilation unit off during cold seasons  In case the M WRG   S ventilation unit has to be turned off  you must operate the M WRG S ventilation unit for a minimum of 10  minutes at ventilation level Ill  in order to remove any remaining moisture in the unit     During cold seasons  we recommend to keep the bedrooms where the M WRG S ventilation unit is installed  tempered at minimum of 166      186 to ensure prope    operation  Higher interior temperatures guarantee a  larger amount of heat recovery     Meltem Warmeriickgewinnung GmbH  amp  Co  KG MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info pmeltem com     www meltem com    a E     M    7  Technical Data       Technical Data M WRG S Ventilation Unit    15 30 60    aluminium plate cross flow heat exchanger    Ventilation air volume  m   h   Fan speed  Heat exchange core  Heat recovery rate  96   Air Leakage  96   an  Power consumption  W   Specific Power consumption  W m  h   Max  current  A   Power cable  mm      Operating voltage  V Hz     Noise level  Lp in dB  A  10 m    concealed  installation    Noise level  Lp in dB  A  10 m    wall mounted  Weight  kg    Air duct diameter  mm    Ventilation unit dimensions  Wx H x D  in mm  Filter class   filter surface in m    Standard filter   Allergy filter  optional     Activated carbon filter  optional     Fully automatic air flap control  even during  blackouts    Condensate drainage  Filter 
9. eltem com     3 2 Replacement of Filters    No tools are required for filter replacement  Both filters  should be replaced at the same time     3 2 1 Remove unit cover         urn OFF the M WRG S ventilation unit  The  air flaps will close automatically     e With both thumbs  press down the two hooks  on the bottom of the M WRG S ventilation unit  and at the same time grab the edge of the  cover with both index fingers and then  carefully lift the cover up and towards you     Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG  Am Hartholz 4     D 82239 Alling     info pmeltem com     www meltem com     8        Meltem    L  FTUNG  amp  WARMER  CKGEWINNUNG       Caution        Always turn the M WRG S  ventilation unit off before you open  the cover and replace the filters     Always replace both filters at the  same time     The efficiency of the unit depends  on the permeability of both filters     mem pere em    5571 Standard filter   M WRG FS  5572 Allergy filter M WRG FA    5573 Activated M WRG FK    Carbon filter             MIT UNS L  FTEN SIE RICHTIG    m CUM Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG    3 2 2 Remove old Filters    e Twist left the filter covers and detach  e Remove old filters and discard        Clean the cap with a damp cloth       3 2 3 Insert new Filters    e Insert new filters  Abluftfilter Zuluftfilter                       mh Sm o v    e Insert the filter covers  making sure the  marked arrows on case and cover are aligned   and turn right       L
10. hrough the air ducts of the   outgoing warm stale air to temper the fresh inflowing heat exchanger core  heat is transferred from the   air  The unit has two fans  one fan extracts the warm warm passage to the cold  while the airstreams are   stale air from the interior and the other fan draws in never combined  The cooled stale air is led out and   fresh air from the exterior  the pre tempered fresh air then streams into the room  without causing a draft            Interior  Exterior     Stale Air Intake Fresh Air Intake                N   N       i               Supply Air Outlet       Exhaust Air Outlet                Stale Air Filter  Supply Air Filter    Heat Exchanger  Stale Air Fan    Supply Air Fan          Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info meltem com     www meltem com      5     m cm Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG        1 3 M WRG S ventilation unit overview    Casing    Cover    Dual switch      p      Power switch ON OFF wm    3 level switch for Ventilation Rate    Supply Air Outlet  Stale Air Intake  Ring Cover for Stale Air Filter    Cover for Supply Air Filter    Facade Cover  Ventilation Hood    Fresh Air Intake    Exhaust Air Outlet       Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info meltem com     www meltem com     n E SM    M WRG S User Manual    2  Start up and Operation    Please ensu
11. inds  etc       e Please follow the instructions contained in this user manual   e Please follow the maintenance instructions contained in this user manual     e Important Indication according to DIN EN 60335  This M WRG S ventilation unit is not to be operated  by persons  including children  with limited physical  sensory or mental capabilities  or lack of experience  and or lack of knowledge  Except if they are supervised  or were given instructions how to use the  M WRG S ventilation unit  by a legal guardian responsible for their safety and security  Children should  be supervised  in order to ensure that they are not playing with the M WRG S ventilation unit     e  fthese Safety and Security regulations are not regarded  Meltem will not be held liable     Safety Advice for installing the M WRG S ventilation unit in rooms with open fire places  For planning and  installation of the ventilation system  the fireplace safety regulations  i e FeuVo  have to be met  Before  operating the M WRG S ventilation unit  the fireplace regulations have to be discussed and approved by the  responsible official authorities and the chimney sweeper     Meltem Warmeriickgewinnung GmbH  amp  Co  KG MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info pmeltem com     www meltem com    A E     NM    m CUM Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG    1 2 How does the M WRG S ventilation unit work     The heat exchanger core uses the heat of the As the air streams move t
12. iu        e  he marking  arrow  on the cap has to align  with the marking on the M WRG S ventilation  unit   e Make sure the covers sit flat and tight on the  cover    e Repeat this process for both supply and stale  air filter caps        Note    Allergy Filter or Activated Carbon Filter need to be  installed for the supply air only  on the right side of  the unit     Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info meltem com     www meltem com    ei E     NM    M WRG S User Manual    3 2 4 Put back on cover    Grab the cover with both hands and position it  as the illustration demonstrates    Move the cover downwards and ensure the  edges snap properly into the rotation screws     Close the cover all the way until it sits loose in  place    Carefully push the cover closed on the bottom  edge until the hooks on each side snap into  place     Turn the M WRG S ventilation unit back on  with the power switch    4  Cleaning the M WRG S  ventilation unit    The M WRG S ventilation unit is made of high quality  synthetic material and only needs little cleaning   From time to time we recommend to clean the  surface of the unit with a damp cloth  In order to  preserve the parts we recommend only to use mild  cleaning detergents     Caution  Never use cleaning detergents that  contain acids or corrosives  Never use a high  pressure or steam cleaners     Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG  Am Hartholz 4 
13. re switching it ON again     Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG  Am Hartholz 4     D 82239 Alling     info meltem com     www meltem com     7     Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG    AUS 11 15           EIN m  30m3 h    60m  h          Flaps closed                MIT UNS L  FTEN SIE RICHTIG    3  Filter Replacement    The clogging of the filters is monitored automatically  by the M WRG S ventilation unit  In case the filters  need to be replaced  an acoustic signal will inform 2   3  weeks prior to the replacement  The intervals of the  acoustic signal will shorten over the time period when  the filter replacement is necessary  You must change  the filters if the acoustic signal sounds for a period of  one second per hour     3 1 Filter selection    e For the M WRG S ventilation unit you have  multiple filter options  For normal operation the  Standard Filter  G4  is sufficient     e For persons suffering from allergies  you may  choose to install the Allergy Filter  F7    only  needed for supply air      e In order to prevent unpleasant odours and  emissions or even harmful gases  gasoline   nitrogen oxides  etc   from entering your  home  you may choose to install the Activated  Carbon Filter  F6    only needed for supply air     e Only use original filters from Meltem   Otherwise Meltem cannot guarantee a smooth  operation and may not be held liable for any  malfunctions     Replacement filters can be ordered at your local  HVAC supplier or at www m
14. re that the M WRG S ventilation unit has  been properly installed by an expert  according to the  assembly instructions and that the exterior of the unit  is not damaged  The interior and exterior intakes and  outlets must not be covered or obstructed     Turn on the M WRG S ventilation unit by switching  the Power ON OFF switch on the left bottom side of  the unit to ON and select a ventilation rate with the  alongside positioned 3 level switch     To ensure a well ventilated and healthy room climate  it is recommended to run the M WRG S ventilation  unit continuously at ventilation level   or    If  needed  switch for a limited period of time to  ventilation level Ill     During the winter season  it is recommended to  ventilate the room once daily for 10 minutes at the  highest ventilation rate  Ill   in order to avoid any  condensate buildup inside the M WRG S ventilation  unit     Caution  Before turning off the M WRG S ventilation  unit while exterior temperatures are below OC  the  unit has to be run for a minimum of 10 minutes at  level III for antifreeze protection     Air flaps    The air flaps will be automatically opened or closed if  the M WRG S ventilation unit is switched ON or OFF   In case of a malfunction make sure the flaps are not  blocked and repeat once again to switch the unit ON  or OFF  In case of a power outage the air flaps will  be closed automatically    After the M WRG S ventilation unit is switched  OFF  please wait a minimum of 15 seconds  befo
15. replacement indicator  Antifreeze protection    International Protection Rating  IP     Approved by German Institute for Civil  Engineering  DIBt            certified  CE     TUV    PRODUCT SERVICE       Meltem W  rmer  ckgewinnung GmbH  amp  Co  KG           high efficiency radial fan with long life DC motor    3 8  5 2  12 5    230   50    G4   0 36    F7 0 32  F6 0 12    through exhaust air duct  Z 51 3 138    IP X1   IP X4       M WRG S K    Z 51 3 138    TUV  GS    PRODUCT SERVICE       MIT UNS L  FTEN SIE RICHTIG    Am Hartholz 4     D 82239 Alling     info pmeltem com     www meltem com      12      Meltem    L  FTUNG  amp  W  RMER  CKGEWINNUNG    
    