1. CAUTION Check We are not responsible for any malfunction or trouble caused by the use of our AN Cracks may develop in the unit casing if it comes into contact with hazardous product or by any problem caused by the malfunction of our unit Please be fully substances such as oil products If this appears all data that was stored in the Logger will have been erased If the unit is being used in an environment where there is a possibility of oil spraying or splashing T amp D advises protecting the unit by placing it in a polyethylene bag aware of this before using our product This product has been designed for private or industrial use only This will be displayed under the following conditions The first time a battery was inserted after purchase If the battery is replaced after having been taken out for a long period Products Specifications Unit type RTR 501 RTR 501L RTR 502 RTR 502L RTR 503 RTR 503L Measurement Channel 1 Temperature Channel 1 Temperature Channel Temperature 1 ruimiaiy Channel Channel Sensor niemal Temo Sensi External Temp Sensor External Temp and Humidity Sensor p TR 5106 TR 3310 15 minutes Approx 30 Sec in air i L Type 25 minutes Approx 4 Sec in agitated water Thermal Time Constant Sensor Response Time ADOUAT P 90 response Measurement Range 40 to 80 C 60 to 155 C 0 to 55 C 10 to 95 RH Avg 0 3 C at 20 to 80 C Avg 0 3 C 5 RH Avg 0 5 C
2. Measurement Accuracy Avg 0 5 C at 40 to 20 C 80 to 110 C Avg 1 0 C at 60 to 40 C 110 to 155 C ai i 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes Total of 15 choices at 25 C and 50 RH Measurement Display O Resolution 1 RH Recording Interval 8 000 Readings Recording Capacity x 2 Channels 16 000 Readings 16 000 Readings x 1 Channel x 1 Channel Recording Mode 4 Endless Overwrite oldest data when capacity is full One time Stop recording when capacity is full LCD Display Items Current Readings Recording Status Battery Life Warning Messages Unit of Measurement Lithium Battery LS14250 SAFT x 1 for L type Large Capacity Battery Adaptor Kit RTR 500B1 x 1 1 External Power Adaptor Kit RTR 500A1 sold separately Approx 10 months L type Approx 4 years FCC Part15 Section247 IC RSS 210 Frequency Range 902 to 928MHz Approx 150m 500ft May vary with conditions Power Battery Life 2 Wireless Specifications Transmission Range Interface Wireless Communication Optical Communication Collection of a full unit of data Wireless communication about 2 minutes Optical communication about 160 seconds IP64 rated for use in daily life 3 H62mm x W 47mm x D19mm Communication Speed Water Resistance IP67 immersion proof Dimensions L Type with Large Capacity Battery Pack D 50mm excluding protrusions antenna
3. QEA ON Displayed during recording or when FULL of data BLINKING Waiting for programmed start Not ON Recording has been stopped 2 Battery Life Warning N Displayed when time to change the battery 3 Measurement and Message Display Area Current measurements or operational messages will appear here 4 Unit of Measurement For details about the message area see the back of this manual correct and re insert the battery e After inserting the battery for the first time nothing may appear or occur for about 10 seconds this is not a malfunction e f plus and minus are mistaken or if the battery terminals and are shorted the recorded data that is stored in the logger will be lost e Make sure no water or foreign objects get inside the case e To maintain water resistibility when changing batteries we suggest also changing the rubber packing and the drying agent About Lithium Batteries e Lithium batteries CR2 sold in stores may also be used but if you are using in an environment below 20 C above 60 C or in a situation such as transportation where continued vibration is likely to occur we strongly suggest the purchase and use of the our lithium battery LS14250 Please purchase optional part 11P2 e When using an LS14250 type lithium battery even though a new battery has been inserted the BAT indicator may remain on for a short time This is due to a special characteristic of the ba
4. length 23mm Weight Approx 56g including 1 lithium battery L Type with Large Capacity Battery Pack Approx 109g Resistance 30 to 80 C Unit temp resistance and measurement range is 40 to 80 C but wireless communication cannot occur in an environment of less than 30 C Unit Temp Resistance Others In order to download data via wireless communication it is necessary to purchase Base Unit 1 When using RTR 500B1 it is necessary to purchase Lithium Battery LS26500 For details contact your local authorized representative 2 The stated battery life is for when it is used in an environment of 25 C 77 F and recorded data is downloaded at a rate of once a day or Monitoring Current Readings occurs at a rate of once every 10 minutes Battery life depends on measurement environment recording interval and battery performance 3 The stated water resistance rating is for when the sensor is connected to the unit However this does not include the sensor areas for the RTR 503 503L models Not for continued immersion 4 When using RTR 500GSM RTR 500NW or RTR 500AW as a Base Unit only Endless can be selected TR 5106 Fluoropolymer Coated Sensor for RTR 502 600 26 i Tal 4 2 2 D Water proof Unit mm Cable Length 0 6m Thermal Time Constant Approx 30 Sec in air Approx 4 Sec in agitated water Possible Temperature Measurement Range 60 to 155 C Sensor Temperature Resi
5. mistakes errors or unclear explanations in this manual specified capacity recording will T amp D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product l l l l l l l stop and FU LL will be displayed This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or Measurement Range Exceeded for RTR 502 indirectly intermittently with the current g This User s Manual cannot be reissued so please keep it in a safe place temperature RTR 502 Celsius The temperature display blinks when Please carefully tead this User s Manual and Warranty p 7 the temperature goes below 60 C or Safety Precautions and Instructions Please carefully observe the following safety measures when using our product Data Capacity Estimate of time until FULL is displayed 1 i Ma a m C lt above tea C 76 F or 311 F To prevent any loss or damage to our customers other people and or property and to ensure the proper use of our products we ask that before using our product you carefully a r T read understand and follow the safety rules and precautions for our products as outlined below Sk cere pees RTR 501 about 4 hours about 5 days about 166 days jabout 1 year and a RTR 502 and 26 minutes and13hours ___jand 16 hours _ 10 months Do not tak
6. e products nor be liable in any manner for legal consequences stemming from the usage of these wireless products in unapproved areas It is not for use in situations where strict safety precautions are necessary such as in AN Pay attention to water leakage or foreign objects entering into the unit case as in the following cases The case was closed with dust hair etc on the rubber packing or in the groove for the packing The rubber packing was damaged In this case please purchase the optional maintenance set The unit suffered from significant temperature change while wet especially if the temperature change was from high to low Do not use or store the unit in places such as listed below It may cause electrocution fire or damage to the unit or to your computer Areas exposed to direct sunlight Areas exposed to water or high pressure water flow Areas exposed to organic solvents and corrosive gas Areas exposed to strong magnetic fields Areas exposed to static electricity Areas exposed to fire or overheating Areas exposed to excessive dust or smoke
7. e apart repair or modify the main unit Store all batteries sensors and Thermo Recorder units out of the reach of children It may cause fire electrocution or damage Ask the shop where you purchased the products or No Sensor It is dangerous to swallow batteries RTR 503 T amp D Corporation to carry out any repairs about 2 hours about 2 days about 83 days shane at monhe and 13 minutes jand 18 hours and 8 hours RTR 501 RTR 502 16 000 data readings x 1ch EX Recording Interval of 30 seconds x Data readings of 16 000 480 000 seconds about 5 days and 13 hours RTR 503 8 000 data readings x 2 ch EX Recording Interval of 30 seconds x Data readings of 8000 240 000 seconds If any smoke or strange smells are emitted from the unit immediately cease using it A Please be careful when using in overly hot or cold environments touching the units Continued use may cause fire electrocution or damage may cause burns or frostbite Do not use any batteries other than those that are recommended The RTR 501 502 are devices to measure temperature The RTR 503 is a device to It may cause fire or damage measure temperature and humidity Do not use these units for any other purpose Displayed when a sensor has not been connected or the wire has been broken Measurement and recording will continue and battery power consumed If water or a foreign object enters the case immediately cease using it about 2 days and 18 hours
8. ea Memory FULL Notices about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Wireless Communication If recording under the ONE This will appear when data is being sent TANDD T amp D and the logo of T amp D Corporation are all registered property of T amp D Corporation i Specifications design and other contents outlined in this manual are subject to change without notice TI M E MODE when the number via wireless communication to the Base We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our Unit product of data readings reaches the On screen messages in this manual may vary slightly from the actual messages ifi i i i Please notify the shop where you purchased this product or T amp D Corporation of any
9. m batteries LS 14250 for long periods at temperatures over 60 C The battery life may be signifi cantly decreased Operate the units with the latest version of Software The latest version software can be downloaded from our home page gt OP OO bb SP A Notes about Sensors TR 5106 the standard Sensor for RTR 502 Do no fold the sensor tip section or expose it to a strong impact This may cause trouble or break the wire The sensor and the cable are shielded by Tefl on If the shield has a defect or tear the waterproof capacity is lost as the shield is very thin Inspect it before operation Insert the sensor tip of least 5cm or more to obtain on accurate temperture measurement Only use the sensor within the sensor heat durability range TR 3310 the standard temperature and humidity sensor for RTR 503 Use the sensor only within the measurable temperature and humidity range Temperature 0 C to 55 C and Humidity 10 to 95 RH The Temperature Humidity sensor cable cannot be extended When the sensor is not used put it in the attached plastic bag with a drying agent and keep it in cool dark place at 5 C to 25 C and 30 RH or less The service life of humidity sensors can vary greatly depending on operating environment Periodic calibration may be required A Compliance Information FCC Statement This device complies with Part 15 of the Federal Communications Commission FCC rules Operation is s
10. nit connect the data logger to the computer For details about how to connect the unit see the Introductory Guide that comes with the Base Unit or see the application s Help Battery Inserted into tube Make sure to use the proper size and type of screwdriver A Phillips 1 head screwdriver is best If using a CR2 lithium battery the tube is not necessary If dirt or scratches are present on the rubber packing water resistance will be reduced Be sure to completely close the cover Make sure not to over tighten the screws Appropriate torque 20N cm 30N cm 2Kgf cm 3Kgf cm 1 Part Names RTR 501 RTR 502 503 2 Connecting a Sensor Make sure that the sensor or sensor adaptor is inserted until you hear a click sound Antenna Communication errors may occur in environments where temperatures are very high or very low If the battery level of the data logger is very low communication may be broken or may not be possible LCD Display Notes about Battery Installation e f a new battery has been installed and recording does not immediately start nothing appears in the display or any other such malfunction please remove the battery check to make sure plus and minus are Optical Communication Area Sensor Jack LCD Display When being used in very cold or hot environments the display may become difficult to read This is not a malfunction Recording Status
11. on 3 Installing the Batter When a battery is installed temperature measurement will start at the factory default settings or the previously set ones 4 Battery Replacement Mark When the replacement mark Zig appears try to replace the battery with a new one as soon as possible 1 When it is time for the battery to be replaced the Zig mark will appear What is a Wireless Thermo Recorder These products are data loggers designed to measure and record temperature and humidity with built in wireless communication capability No longer it is necessary to manually gather the data loggers Rather via our special radio communication function data download settings analysis and the saving of data can all be done via a wireless Base Unit connected to your PC Factory Default Settings Recording Mode Endless Wireless Thermo Recorder User s Manual RTR 501 RTR 502 RTR 503 Recording Interval 10 minutes Recording Start Immediate Start If you do not change the battery and continue using the unit the temperature display will intermittently display bAtt 1 Remove the screws and open the case 2 Insert the tubed battery into the case as shown in the diagram below Check the rubber packing for any cuts or scratches and replace the cover as it was when opened RTR 501 RTR 502 RTR 503 With Internal With External Temperature With External Temperature Temperature Sensor Sensor TR 5106 Included Humidity Sen
12. sor TR 3310 Included 3 After this point the downloading of data can no longer be done via wireless Communication Without changing the battery and attempting to use optical communication to download data the communication may be broken and if so all recorded data may be lost If the battery is changed at this point recording will continue after it has been changed 3 If the battery is further left unchanged the display will automatically shut off SDHEL If at this time the battery is changed CHEC will appear in the display after which recording will begin again using the previously set recording conditions Common Items Included Lithium Battery LS14250 x 1 inserted into a tube Strap x 1 User s Manual Warranty x 1 T amp D Corporation http www tandd com Shimadachi 817 1 Matsumoto Nagano JAPAN 390 0852 Fax 81 263 40 3152 We have prepared an array of Remote Units to meet your needs RTR 501 502 503 These Remote Units cannot be used without a Base Unit Base Units must be purchased separately All of the recorded data up until that point will be erased 5 Communicating with a PC Copyright T amp D Corporation All rights reserved A If you are using a This is printed using recycled paper commercially purchased battery please place it in the 2011 08 16504590015 4th Edition tube To register a data logger as a Remote U
13. stance 70 to 180 C Temp Measurement Accuracy Avg 0 3 C at 20 to 80 C Avg 0 5 C at 40 to 20 C 80 to 110 C Avg 1 0 C at 60 to 40 C 110 to 155 C Water Resistance The fluoropolymer coated section is waterproof Other sections are immersion proof IPX4 Materials Thermistor Fluoropolymer coated Electrical Wire TR 3310 Temp Humidity Sensor for RTR 503 700 63 4 26 Tal Unit mm Cable Length 0 7m Possible Temperature Measurement Range 0 to 55 C Possible Humidity Measurement Range 10 to 95 RH Sensor Temperature Resistance 10 to 60 C Measurement Accuracy Temperature Avg 0 3 C At 25 C 50 RH Humidity Avg 5 RH At 25 C 50 RH Conditions for Use Under conditions without condensation water leakage or effects from corrosive gas or organic solvents Water Resistance None Materials Temperature Humidity Sensor Polypropylene Resin Vinyl Chloride Coated Electrical Wire connection with medical equipment whether directly or indirectly Do not drop or expose the unit to strong impact Do not put your fingers or foreign matter into the sensor connection Battery terminals may provide insufficient contact due to age or vibration Please be careful not to lose data due to insufficient contact Battery life depends on the measurement environment communication frequency recording interval and battery quality Avoid using the lithiu
14. ttery Note that the longer the battery has been in storage the longer the amount of time from 10 minutes to about 1 hour the BAT indicator will remain on If during that time the Base Unit is used to get the Current Status of the Remote Unit the remaining battery level will show that the battery level is low e Please store the Lithium Battery LS14250 in a place that is 20 C or less Estimating Lithium Battery Life A new battery should last about one year if it is used in an environment of 25 C 77 F and recorded data is downloaded at a rate of once a day or Warning Monitoring occurs as a rate of once every 10 minutes About using in Low and High Temperature environments Use in Low temperature environments will result in a shortening of the battery life 20 C 4 F one half of life compared to normal temperatures 30 C 22 F one third of life compared to normal temperatures In normal temperature environments the GZ mark may not appear but under low temperatures this mark may appear and communication may be impossible Use in High temperature environments will also causer battery life to be shortened 60 C 140 F one half of life compared to normal temperatures In environments of 60C or higher not only will battery life be shortened but the unit itself and its parts will deteriorate more rapidly Please do not use in such environments for prolonged periods of time 6 Message Ar
15. ubject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note about Antenna Usage This device has been designed to operate with the supplied antenna only Use of any other antenna is strictly prohibited IC Statement This device complies with RSS 210 of the Industry Canada IC Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Ce dispositif est conforme a la norme RSS 210 d Industrie Canada Lutilisation de ce dispositif est autoris e seulement aux conditions suivantes 1 il ne doit pas produire de brouillage et 2 l utilisateur du dispositif doit tre pr t a accepter tout brouillage radio lectrique re u m me si ce brouillage est susceptible de compromettre le fonctionnement du dispositif A Important Notice Wireless products cannot be used in countries other than where those products have been approved for use according to that country s wireless regulations T amp D Corporation shall in no manner whatsoever take responsibility for the usage of thes