Home
DGT60 Repeater - Mettron Weighing Ltd
Contents
1. of outputs activation thresholds 350 Ohm minimum applicable voltage resistance 10 Reading Writing of Alibi Memory kohm DGT60BC and DGT60AN models Reading of microvolts or ADC converter for all the channels Message display Printing Setting of APW in counting mode Simulation of PRIUS US kir ae d u key pressure MODBUS serial protocol e Version with specific program for use of the indicator as a e THROUGH 16 bit ANALOGUE OUTPUT DGT60AN universal weight repeater or as a multi scale repeater Analogue output proportional to the net or gross weight MASTER in combination with DFW DGT MCW either positive in loading or negative in unloading e FUNCTIONING MODES Multi scale repeater MASTER function which allows to repeat up to 32 independent scales with the possibility of managing their functions or displaying and printing the sum of the weighs of all the scales UNIVERSAL weight repeater function which allows to repeat the weight of any scales through the configuration of the input string OPTIONS ONLY AVAILABLE AT TIME OF ORDER e Option Box with thermal printer e Ethernet interface e External 868Mhz radio modem e 433MHz radiofrequency remote control e Real time clock e Alibi Memory Available versions Code Description DGT60BC Weight indicator with IP68 stainless steel case 5 key keypad and 60 mm LED display DGT60AN Weight indicator with IP68 stainless steel case 5 key keypad 60 mm LED displa
2. DGT60 MAXI GOLIAH WEIGHT INDICATOR REPEATER DGT60 indicator repeater 165 mm 185 mm Dimensions in mm DGT60BC DGT60AN DGT60PB FUNCTIONS THROUGH KEYBOARD Zeroing Semi automatic and presettable tare print and or data transmission ON Stand by SELECTABLE High Resolution Weighing x 10 Net Gross or Ib kg conversion Weighs totalisation Formulation Approved transmission of the weight to PC PLC with ALMEM Alibi memory option Counting In Out Truck weighing Hold e Peak EXTERNAL INPUT Simulation of key pressure Keyboard lock MOSFET OUTPUT Set Point Control on the weight either positive in loading or negative in unloading or on the pieces counting mode with programmable enabling disabling thresholds as direct check or upon weight stability SERIAL PORTS On all models Reading of the net gross and tare weights Clearing Semi automatic and presettable tare Weight indicator repeater with large matrix display composed of very intense bright LEDs Particularly suitable for use outdoors also in full sunlight and where it s necessary to view from a distance at any angle Case completely in IP68 stainless steel CE M approvable OIML R 76 EN 45501 MAIN FEATURES Functional 5 key waterproof keypad Large 6 digit display 60 mm high with very efficient SMD LEDs software adjustment of the brightness intensity complete of 6 Leds for indication of active functions vis
3. ible from over 25 m with viewing angle up to 120 and with power up to 750 mcd IP68 stainless steel case complete of wall fixing bracket Dimensions 410 x 67 x 165 mm Calibration Set Up parameters configurable from keyboard or from PC with DINI TOOLS Max 10 000e or multirange 2 x 3000e 0 3 uV d in CE M approved version for legal for trade use Max 800 000d viewable with internal resolution up to 3 000 000 points Up to 8 signal linearisation points with DINITOOLS A D 24 bit sigma delta 4 channel conversion max 200 conv sec with automatic selection Connectable with up to 16 analogue load cells with 350 Ohm input resistance Management of a weighing system with up to 4 cells with digital equalisation or management of up to 4 independent weighing systems Power supply from 12 to 24 Vdc with 110 240 Vac internal power supplier Available as Scale or as Repeater version I O SECTION RS232 C bidirectional port configurable for connection to printer PC or other external units RS485 bidirectional port configurable for connection to PC PLC or other external units PROFIBUS serial interface DGT60PB model 2 photomosfet outputs 150 mA 48 Vac 150 mA 60 Vdc NO with configurable functions 2 optoisolator photocouplers 12 24 Vdc 5 mA min 20 mA max with configurable functions 16 bit analogue output DGT60AN model 4 20mA 0 5Vdc 0 10Vdc at choice maximum applicable voltage Scale switch Setting
4. oors 150m outdoors 50 configurable channels OBRFUSB must be combined with another radio module 868 MHz radio frequency module for PC ABS IP65 protecting box 3 m RS232 connecting cable complete with DB9 pin connector and external power supply Max functioning distance in appropriate environmental and installation conditions 70m indoors 150m outdoors 50 configurable channels OBRF232 must be combined with another radio module Real time clock for printing displaying of the date and time Alibi memory fiscal memory max 120 000 weighs for approved transmission of the weight to PC PLC Real time clock integrated for print of the date time 433MHz radio frequency remote control with 6 keys for use up to 50 m of distance in appropriate environmental conditions Integrated Ethernet interface with speed from 10 to 100 Mbps TCP UDP IP ARP ICMP Ethernet Mac protocols Ethernet cable 1 5 m long for connection between indicator and PC network Made up of fairlead Shielded cable for platform 50 cm female connector to be soldered Shielded cable for platform I 50 cm 5 m extension cable Shielded cable for platform 50 cm cable 10 m extension cable RS232 C cable 1 5 m for the connection of the weight indicator to PC made up of 9 pole female connector on PC side and wires for terminal connection on indicator side RS232 connection cable 5 m for the connection of the weight indicator to a weight repeater witho
5. ut connectors RS232 C cable 10 m for the connection of the weight indicator to a weight repeater without connectors Kit of 3 passive safety zener barriers for up to 4 load cells of 350 ohm housed in an ABS box for intrinsic protection weighing systems in a hazardous area Marking of the single barrier ATEX II 1 GD Ex ia IIC Ex iaD Marking of the whole box with three Zener barriers ATEX II 3G Ex nA II T4 IP65 20 C lt Ta lt 40 C Declaration of ATEX conformity of the whole Ex II 2GD IIC T6 T125 C X system with relative label of whole system for NON ATEX weight indicator connected to Dini Argeo zener barriers connected to mechanical structure with ATEX load cells each cell must be certified with CCATEX option ATEX CONFORMITY DECLARATIONS will be supplied in English Technical assistance by telephone or at our premises for instrument configuration and printout formatting NET HOURLY PRICE Description Stainless steel fixing bracket for mounting the weight indicator on wall with adjustable inclination Power adapter from Schuko to BS1363 Printed technical manual free if downloaded from the web NET PRICE Printed user manual free if downloaded from the web and available in the CD fitted with the product NET PRICE
6. y and 16 bit analogue output DGT60PB Weight indicator with IP68 stainless steel case 5 key keypad 60 mm LED display and PROFIBUS interface DGT60R Weight repeater with IP68 stainless steel case 5 key keypad 60 mm LED display and configurable protocol Options only available at time of order Code Description KCEM Kit of plates and Welmec form for the approval of the system for legal for trade use for each provided platform weighing system connected to Dini Argeo indicator VENT Air valve for regulating the humidity and the pressure inside the indicator advised for IP68 applications OBTPRI60 Thermal printer for mounting attached to weight indicator with stainless steel case connection cable internal power adapter for mounting inside the indicator Combinable with DGT60 series indicator OBRF External 868 MHz radio frequency module ABS IP65 protecting box 3 m cable power supply from weight indicator Max distance in appropriate environmental and installation conditions 70m indoors 150m outdoors 50 configurable channels OBRFUSB OBRF232 DFCLK ALMEM TLR ETH ETHCBRJ LCCBC LCCB5C LCCB10C RSCBPC RSCB5 RSCB10 KMB4 DCATEXMB4 TECSUP Accessories Code STFR UKPLUG TECMAN UMAN 868 MHz radio frequency module for PC with PVC box and 1 m USB mini USB connecting cable power supply directly from the USB port Max functioning distance in appropriate environmental and installation conditions 70m ind
Download Pdf Manuals
Related Search
Related Contents
Onkyo TX-NR747 Product Sheet Model 5725 VelociCalc Manual DigitalFlow™ XGF868i Service Manual CodeReporter 1 yaskawa a1000 guia rapida de inicio VERRES CAPITOLATO SPECIALE D`APPALTO PMP 8600 554 kB S.O. Windows98, NT, 2000, ME, XP Mises en garde Copyright © All rights reserved.
Failed to retrieve file