1. ACFW1 STANDARD DOOR WINDOW CONTACT USER MANUAL gt Z Magnet Eo Features EXTRA Low current draw S M D Technology Excellent false alarm suppression Introduction The Wireless Magnetic Contact uses a magnetically operated switch to sense the opening of the door or window The Wireless Magnetic Contact is easy to install without connecting any cables from the security Control Unit Detector The Wireless Magnetic Contact is compact attractive and easy to install it can be mounted on a window or a door The Wireless Magnetic Contact is ideal for commercial office and residential applications The Wireless Magnetic Contact detects intrusion by determining open or close of the magnetically operated switch Please follow the following steps in order to ensure you correctly install 1 Installing the batteries in the Detector s Note Do not use rechargeable zinc carbon or zinc chloride batteries in the detectors 1 Slacken screw on base of detector and lift off cover 2 Remove screw from battery cover and remove cover 3 Insert two AAA size alkaline batteries as shown Taking care to observe correct polarity Illustration 1 4 Replace battery compartment cover and screw Terminals for connecting to Wired Contact Batteries AAA size x2 Note The Magnetic Contact is able to expand by adding on a Illustration 1 Wired Magnetic Door Window Contact Accessory DC2 aia 2 Programming the detector into
2. Easy Set Module APFES APFW10 eae S en ea aero 5 LRO3 size 1 5V b 2 1 Press Learn button on APFES APFW 10 board it gives two beeps then yellow LED is on to indicate learn mode now after release off greater than 40mm A 2 2 Under learn mode of APFES APFW10 trigger unregistered wireless detector RED LED on APFES APFW10 will flash fast twice and give two beeps to indicate OK 3 Power OFF the CU Power OFF the CU completely after the Detector s have been learnt by isolating the backup power battery and mains power adaptor to prevent the tamper function of the Detector s from triggering the alarm of the CU when mounting 4 Mounting Location This product contains a radio transmitter and should not be sited on or near large metal objects The detector consists of two parts It is designed to detect a door or window opening For optimum radio range the detector should be mounted as high on the door as possible Mounting the detector There are two parts to the detector The larger section is actual detector and contains the batteries and the electronics The smaller section is simply a magnet Illustration 2 1 2 5 6 Choose where on the door or window you wish to locate the unit The transmitter unit is usually mounted on the frame and should be positioned such that the red LED is closest to the door or window edge The magnet should be fitted as shown Illustration 3 with one narrow edge level with the
3. flat top on the detector housing The gap between the magnet and detector should be no more than 10mm with the arrow on the magnet pointing directly towards the arrow on the detector If there is insufficient room to mount the detector on the frame then it can be fixed to the door or window instead with the magnet fixed to the frame alongside it For reliable operation the front face of the magnet should be no more than 8mm below the front face of the detector in some cases it may be necessary to place packing behind the magnet or detector to achieve this Remove and retain the screw from the bottom of the detector Illustration 4 Using a small drill or screw driver to make two fixing holes in the backplate as a template mark and drill two fixing holes Fix the backplate in position using the screws provided O e A ED AE e Mounting Holes DOOR WI NDOW FRAME Les el ee 8mm MAX S Illustration 2 Illustration 3 Illustration 4 Locate the detector on the backplate and replace the retaining screw at the base off the unit Align the magnet as described above and fix in position with the two screws provided Note If you are fitting the unit to a PVC door or window you may wish to use STRONG double sided tape to fix both the detector and magnet in position 5 Power the CU again Power up the CU again The system will return to standby ready for use Specifications Type Magnetica
4. lly activated switch with option for external wired contact detectors Housing ABS Transmission range 150 metres open air with direct line of sight Transmission frequency 433MHz LED Transmission indication Power Supply 3Vdc 2 x 1 5V AAA Alkaline battery Battery Life Approx 18months Distributed by Challenger Security Products 4 Arkwright Court Fylde Industrial Estate Blackpool FY4 5DR Tel 01253 792898 Fax 01253 791887 Email Enquiries challenger adivision co uk Web www challenger co uk
Download Pdf Manuals
Related Search
Related Contents
Manual - Tramontina お客様へのお知らせ/シーズンオフメンテナンスのご案内 SCBT-MR Annual Course Ritz Carlton New Orleans, LA September 3010 Installation Manual UDC 2500 - Perceptive Industries 10000506353 R02 S Usuario CFW-11 Mec E.indd Notice - Deaco METTLER TOLEDO Impact S® User`s Guide Copyright © All rights reserved.
Failed to retrieve file