Home

ATS22 - Electronic Power Solutions

image

Contents

1. Quick start guide Altistart 22 HNM Preliminary information S1A1038801 Information below is designed to use for simple applications with 2 wire control mode and freewheel stop If you need more information or for other applications see the User manual on www schneider electric com For a hard copy contact your local sales Office or Schneider Electric representative Note DO NOT USE this guide for Altistart 22 connected inside the delta of the motor it means Altistart 22 connected to the motor with delta connections in series with each motor windings In this case see User manual on www schneider electric com Read and understand these instructions before performing any procedure with this soft starter A A DANGER HAZARD OF ELECTRIC SHOCK EXPLOSION AND ARC FLASH Read and understand this manual before installing or operating the Altistart 22 starter Installation adjustment repair and maintenance must be performed by qualified personnel e The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all equipment e Many parts of this soft starter including the printed circuit boards operate at the line voltage DO NOT TOUCH Use only electrically insulated tools e DO NOT touch unshielded components or terminal strip screw connections with voltage present e Before servicing the starter Disconnect all power including external control power that wi
2. Control voltage Volts Soft starter control voltage range _____ Volts S gt 100 mm 3 9 In Mount the soft starter vertically For a surrounding air temperature up to 40 C 104 F A DANGER HAZARD OF ELECTRIC SHOCK EXPLOSION AND ARC FLASH ATS22 soft starters are open devices and must be mounted in a suitable enclosure Pe acm Failure to follow these instructions will result in death or serious injury For other thermal conditions see user manual on www schneider electric com a Schneider fP Electric S gt 100 mm 3 9 In www schneider electric com 1 4 S1A10388 08 2009 Connect the soft starter For ATS22e0eQO or ATS22ee0eS6 Ground connection 2 wire control freewheel stop AL YAI E l i l 4 a Connect Power 4 Wire the soft starter to the ground 4 Wire the soft starter to the line supply 1 L1 3 L2 5 L3 L Check that the motor voltage is compatible with the soft starter voltage H Wire the soft starter to the motor L a Check the operating limits of the contact 2 Select a voltage transformer in accordance with the mains voltage sS Check that the control supply IS 2 5 OV for CL1 and CL2 Remove the red sticker which covers the CL1 CL2 terminals Wire control supply CL1 and CL2 Wire logical inputs LI1 and LI2 Wire the relay R2A and R2C Note For additional information in order to size the protective and control de
3. limit ISU oF In ELS Max start time ISs SEE Adjustments ALL Acceleration time IOs dEL Deceleration time F r E E Freewheel EdLl Final torque ij EHF Motor thermal protection O IEC class 10 r d H soft starter ready when power and control voltage are present and the motor is not operating n r d 4 when power is not supplied and control voltage is supplied or when power and control voltage are present with LI1 not connected and LI2 present run command Short circuit rating and branch circuit protection use in place of Q1 shown on page 2 and 3 Recommended fuse ratings for UL and CSA requirements Components for use together in accordance with standard UL508 a E a a area Soft starter 208 600 V 60 Hz 10 15 Standard rating product rating SCCR X Z1 1 ATS22D170660 Suitable for use on a circuit capable of delivering not more than ATS22D32000 ___X____ rms symmetrical Amperes 575 Volts maximum when protected by ___Z 1____ with a maximum rating of___Z 2___ ATS22D62e0e AJT125 1 Ferraz Shawmut manufacturer ATS22D75eee AJT175 ATS22D88ee0e AJT200 2 x AJT350 2x 350A ATS22C4 1000 2 x AJT400 2x 400A ATS22C48e0e 2 x AJT500 2x 500A ATS22C59eee 30 kA 2 x AJT600 2x 600A www schneider electric com 4 4 S1A10388 08 2009
4. ll be present Place a DO NOT TURN ON label on all power disconnects Lock all power disconnects in the open position e Before applying power section close the enclosure Failure to follow these instructions will result in death or serious injury Electrical equipment should be installed operated serviced and maintained only by qualified personnel No responsibility is assumed by Schneider Electric for any consequences out of the use of this material Check the delivery of the soft starter suet TE For rating and protection refer to installation Remove Altistart 22 from the packaging and check that it has not been damaged Ctri WV FH Cu AWG12 75 C 19 110115 50 60 4 5lb in 0 5Nm A WARNING Icl 17A 208 600V 3 50 60Hz v 208 230 400 440 460 500 575 DAMAGED SOFT STARTER EQUIPMENT 3 Pe JUE 1EC60947 4 2 Do not operate or install any soft starter or soft starter accessory that appears damaged Motor overioad protection class 10 A Cu AWG10 75 C 26lb in 3NM Failure to follow these instructions can result in death serious injury or equipment CECEO damage Check that the soft starter reference on the nameplate is similar to the purchase order delivery note T owosozo000 Check the line voltage compatibility Check that the line voltage is compatible with the supply range of the soft starter Line voltage Volts Soft starter voltage range Volts
5. t L m line voltage Adjust nm motor rated current e Push scroll down button W to reach c on F menu Inc on F menu e Push ent button e Push scroll down button W toreach n parameter e Push scroll down button W to reach U In parameter e See Nominal Motor Current on Motor Nameplate e Set LI n to the main line voltage ac value using scroll Up down Motor Full Load Amps in STAR connection note the Amps value e Push ENT button to validate the U n value A Vv e Set n to this value using scroll Up down Push ent button to validate the n value Apply power to the Altistart 22 and start the motor e Close the enclosure e Push S2 button e The soft starter displays r d Y e Close S3 the motor starts Factory settings The Altistart 22 is factory configured for most standard applications If the factory configuration is not suitable for your application refer to User manual on www schneider electric com Here is the list of writable parameters in an easy start up mode Menu Code Description Factory setting Customer setting ICL Soft starter rated current According to the soft starter rating dLEA Connection type Line or delta L Tae U In ees ere ATS22 e0 range 4 O O Vac canF J ATS22 eS6 S6U ranges 4 B O Vac Configuration A In Motor rated current According to the soft starter rating Cod Setting lock nl oL Not locked LAC Advanced mode HFF Egi Initial voltage J O of input voltage ILE Current
6. vices refer to the catalog or the user manual available on www schneider electric com www schneider electric com 2 4 S1A10388 08 2009 Connect the soft starter For ATS22eeeS6U Ground connection J AUS UAI wire control freewheel stop O H soree ual O l a Connect Power 4 Wire the soft starter to the ground 4 Wire the soft starter to the line supply 1 L1 3 L2 5 L3 V Check that the motor voltage is compatible with the soft starter voltage L Wire the soft starter to the motor L Pad INN AAN s Ground connection P p I o I I Q2 110V L 2 1 2 aA a sd 2 1 Q3 2 A o e eTa O oO oo 2 P O A Q 0Q O 0 0 O0 O 1 Check the operating limits of the contact L 2 Select a voltage transformer in accordance with I the mains voltage L ay gt Check that the control supply IS 1 1 OV for CL1 and CL2 4 Remove the red sticker which covers the CL1 CL2 terminals 1 Wire control supply CL1 and CL2 Wire logical inputs LI1 and LI2 Wire the relay R2A and R2C Note For additional information in order to size the protective and control devices refer to the catalog or the user manual available on www schneider electric com www schneider electric com 3 4 S1A10388 08 2009 Power on the control e Check that S3 is open e Switch on Q1 Q2 Q3 and Q4 e The soft starter displays nr d 9 Adjus

Download Pdf Manuals

image

Related Search

Related Contents

Hardware interconnection of the STM32™, SPEAr™3xx, and ST75xx  MANUAL DE INSTALACIÓN EN CAMPO    service manual fm/am cassette car stereo  Kodak M200 User's Manual  Manual  Working with BR-Receipts  USER MANUAL 5.0    FAQs - Central Washington University  

Copyright © All rights reserved.
Failed to retrieve file