1. Pa rd nap NanRRNRRRARRRRRRARERERRRERRRRRRRRRAREEERREARRRRRRRRRRRRRRNRARRRG UT 1 GENERAL I NFORMATI ON dehumidifiers provide an effective and efficient solution to humidity control Ikeno high teraperature type dehumidifiers 10 3750 are designed Tor airflow of 3000CMH and easily instailation Moreover the units are designed for duct installation so that there are more option for system installation Model ID series designed by our company is the most reliable unit in the range It dehumidifies air by dropping air temperature below its dew point to condensate out moisture vapor The condensation water is discharged out by drainage hose and air temperature is raised going through condenser coil Ikeno dehumidifier can keep the air dry reduce the cost of heating restrain the growing speed of germ fungi maintain the suitable humidity and reduce the cost caused by dampness The ID standard type dehumidifiers are widely used in places where the relative humidity must be controlled and room temperature is a bit higher than ambient such as low drying kiln non insulation storage in hot climate area other special hot and humid working storage places PRODUCT DESCRi PTI ON 1 MAIN FEATURES e he enciosed compressor is made in Europe U S A and Japan The SAGINOMIYA humidity controller and SAGINOMIYA pressure protection switch e A wide applicability It can be used in a low temperature high humidit
2. Subject to change without prior notice 5 SPECI FI CATI ON STANDARD MODEL Capacity D lt J ee Note N Nominal working condition 27 0 C DB 21 2 C WB Low temperature working condition 5 0 C f DB 2 1 C WB High temperature working condition 500C 6 MOI STURE REMOVAL CAPACI TY MOISTURE REMGVAL CAPACITY kg h ROOM RELATIVE HUMIDITY I KENO INDUSTRIAL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice 7 ELECTRI CAL DI AGRAM L1 Lo z LTP Low pressure switch COMP Compressor HTP High pressure switch TR1 Time relay 3 min MCL Main insulator amp coil TR2 Time relay 30 min FU Fuse 1 KENO I NDUSTRI AL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice INSTALLATION 1 Receiving inspection Remove the shipment packing and inspect unit to ensure that no damage has occurred during transportation and storage Any visible damage must be reported to nearest Ikeno representative 2 Working Environment The unit should be installed stablv There should be one meter of space in front of the inflow and outflow There should be no large obstacle around it The machine set should be far from heat Source and inflammable gas The condensed water could be drained out of the room or into a pail Itis advisable to not to install it in a place
3. a little neutral detergent to wash it or to brush it and then wash with clear water Attention a The air filter should not be exposed directiv to sun of fire to avoid deforming b The air filter should be fixed before startirg the dehumidifier VI TROUBLES AND COUNTERMEASURES Problem Cause Solution Unit does not operate Power failure Check and solve problem Power source is not switched not well plugged Fuse is broken Unit dees not operate Room humidity has lower Turn humidistat to higher although there sn power than set humidity value to see whether the problemn humidistat unit re operate the reset initial position Capacity reduction Air filter dusted Clean air filter i Breined water leaks out Drain pipe is blocked Remove the front panel and wipe off dirt from the pipe VII POINTS TO REMEMBER 1 Its outlet dry air temperature is higher than inlet air temperature but outlet aire moisture content is lower When the dried air is sent to one space it soon will mix with the space s wet air and absorb the numidity So normally space s humidity will decrease after half an hour of operation However temperature of the space will be little bit higher if the space uses dehumidifier for drying for a long time 2 Before being used the whole set of dehumidifier should be earthed 3 After opeing the packing pls check whether there is any damage of t
4. of heavy dust or serious paliution Power source The power shouid bDe suppiied with a special wire Provide automatic circuit breaker There shoutd be reliable electrical grounding 4 W Other requirement Skilled professional personnel should perform maintenance of the unit Parking inclination of the unit should not exceed 10 IV OPERAT ON PROCEDURES 1 Turn on Switch on the main insulator provided by contractor The power lamp 2 is on Turn hurnidistat knob 5 to desired value Puep ON button 3 to start the unit Notice in case the unit has iust been stopped for less than 3 minute the delay relay keeps the turn on for 3 minutes to protect compressor The Operation lamp 1 is on and unit starts working 2 Turn off Push OFF button 4 to turn the unit off Switch off main insulator Notice Vapor pressure gauge 6 used to check compressor performance technical personal only V MAINTENANCE Switch off the power source before maintenance Due to the accumulation of dusts the air filter should be cleaned to avoid effecting dehumidifying and going wrong periodically at least once a month IKENO I NDUSTRI AL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice 1 Clean the air filter When cleaning gently tap the air filter or remove the dust with a vacuum cleaner or you can put the air filter in warm water lt 40 C add
5. al USER S MANUAL T Eu IN Mil DU ll Mods 10 3750 Standard type I KENO DEHUMIDIFIER CONTENTS Page I GENERAL INFORMATION 2 I PRODUCT DESCRIPTION 1 MAIN FEATURES PO 2 COMPONENT IDENTIFICATI ON 3 3 WORKING PRINCIPLE 3 4 DIMENSION 4 5 SPECIFICATION 5 6 MOISTURE REMOVAL CAPACITY 5 7 ELECTRICAL DIAGRAM 6 IN INSTALLATION 1 RECEIVING INSPECTION 7 2 WORKING ENVIRONMENT 7 3 POWER SOURCE 7 4 OTHER REQUIREMENT 7 IV OPERATI ON PROCEDURES 7 V MAINTENANCE 7 V FROUBLES AND COUNTERMEASUREMENTS 8 VI POINTS TO REMEMBER 8 I KENO INDUSTRIAL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice 099 3 3RERERRERRRERRRRRERRERREERERRERERRRERRRRERRRERERRRRERRA NESCONURSRRERRERRERERREREERERRERGG bh n NOTICE Please read and follow the instruction in this manual carefully and keep it in a suitable place for further references e Warrantee 12 months from commissiening date in the condition that the unit are operated and maintained according to those instructions in this manual e Safety information D series high temperature type dehumidifiers are designed and built witi carefulness to ensure that most of the safety requirements by international institution However the users must be responsible for general safety rules to protect himself and the units TTT ef We e Deennnnnnntannnnnnnnnnnnnnnnnnneeg
6. e machine should be far from heat sources inflammable and explosive gases 12 Try to be far away from dustv environment or the place where it is polluted seriously by acid alkali chemical 13 For three phases machine set you should be sure that the running direction of fan is correct The running direction of fan wheel points to machine s fron face 14 Adjust humidity controller set one required humicity value 15 Press ON button to start Fan 16 The compressor will start after 3 minutes time delay 17 When the machine just start or surrounding temperature is low the red lamp will turn on This situation is normal 18 When humidity reduces to the setting value dehumidifier s compressor will stop when temperature increases it wil restart 19 Drain pipe can connect with ether pipe to drain the water out 20 Before using you should pay attention to check whether electricity power is suitable for machine s power requitement 21 The electricity parts should be far away from rain or water with the purpose to avoide electric leakage f the above situation happens you should have some dry treatment 22 ou sbould clean the surface periodically But decontamination reagent or other organic solvent to clean it 23 The A Filter for inlet air should be cleaned once a week If surrounding environment is much dusty the cleaning time should be shorter 24 When the machine is moved to another place the machine should be
7. he machine due to transoort whether the connecting line of each electric parts is tip off loosen or cut off It there is please try to repair it 4 Dehumidifier should be avoided from sunlight and other heat sources such as burner Please let its surrounding air be circulating especially inlet air entrance 5 Drain pipe should lead to cloacae lengthened by rubber pipes so that coagulate water can be moved out If no cloaca then the coagulate water have to be drained outside 6 Turn the knob of humidity controller to required value of relative humidity then the compressor can start or stop based on this value circulating fan will operate continuously I KENO INDUSTRIAL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice 7 The machine should be stopped if the operating situation is against the following points Otherwise the machine will be easily damaged The fluctuating scope of voltage cannot be over 10 of thie rating voltage The interval of each operation cannot be less than 5 minutes otherwise it would cause damage to compressor Moreover operation times cannot be more than 6 times per hour 8 The dehumidifier has time delay protection 9 Even in a satisfied working environment humidity s setting value should be a little bit higher 10 Make sure that the setting of the whole machine should be stable and there is no other big obstruction around the machine 11 Th
8. n the dew point temperature of the air the water content in the air is CERAM CONDENSATED WATER condensed and drained from the machine The dehumidified air is then heated by the condenser and is discharged into the room by the centrifugal fan Thus the air goes through the cycle and the water in the air gets condensed so as to achieve dehumidification SCH When the environment temperature is lower 5 18 C during running the surface of the evaporator will be frosted due to lower temperature The computer will judge and IKENO I NDUSTRI AL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice send the defrosting command automatically as the situation After defrosting the dehumidifier will turn back to run normally order to protect the unit from severe damage during operation the unit is equipped with such a safety features such as low pressure cut off compressor overload protection defrost cycle main short circuit fuse 4 DIMENSION 1160 317 535 1420 535 173 276 276 238 530 197 I KENO INDUSTRI AL DEHUMI DI FI ER USER S MANUAL Model I D series
9. s limited to a free exchange complete with free freight of faulty units or components which have failed as a of faulty quality or defects in manufacture Ikeno guarantees that the delivered unit has undergone rigid testing to ensure that the specificatoins stated here are fulfilled All claims on warranty must verify that the fault has occurred within the guarantee period plus that the unit has been used within its operating range as stated in the specification All claims must include the unit type and manufacturing number Conformity with directives and standards The ikeno dehumidifier is designed and manufactured by an EN ISO 9001 accredited development and manufacturing organization The unit conforms with the specifications in the Machinery Directive 98 37 EEC the Low Voltage Directive 73 23 EEC as amended by Directive 93 68 EEC and the EMC Directive 89 336 EEC as amended by Directives 92 31 EEC and 93 68 EEC The standards applied are listed in the EC Declaration of Conformity FK 2K ok 2K ok K 2K K 2K K ok ok ok ok ok ok FK FK ok ok ok ok ok ok FK ok FK K FK K ok ok ok FK K ok ok ok ok 2K ok FK 2K FK FK K FK ok ok ok FK ok K ok ok ok ok ok FK 2K 2K ok I KENO INDUSTRIAL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice
10. with vertical position If it need to lean the angle with the horizon should be less than 45 degree I KENO INDUSTRIAL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice 10 25 When turn on the machine if it cannot work then you shouid check the connecting wires are in a normal situation or not For circuit drawing please see the attached picture 26 If the refrigerating system works normally please do not open it For is is the closed type it is no need to add cryogen 27 When the machine is under operation if there is metal colliding sound you should stop the machine and check whether the screws of Fan is loosened or disengaged 28 After 20 minutes operation the drain bipe will have some water to be drained out Refrigerating water should be Sun of the basin so that it will be drained out Jr the temperature humidity is lower th time needed will be longer This is normal If the troubles have not been removed yet please contact the dealer IMPORTANT USER I NFORMAT Intended use of the unit The ID series dehumidifier is inteneded to be used for the dehumidification of air All other uses of the equipment or use which is contrary to the instructions given in this manual can cause personal injury and or machine damage Warranty and obligations The warranty period is 12 moriths from cammissioning date unless otherwise advised in writing The warranty i
11. y and a high temperature high humidity environment e Automatically control humidity It can save operation cost by automatically controlling the operation based on the humidity setting I KENO INDUSTRIAL DEHUMI DI FI ER USER S MANUAL Model I D series Subject to change without prior notice e The unit can be installed conveniently The conventional type and the wall hanging type can be installed on anyplace in the room and can be used after being powered The unit installed outside must be covered under shield to avoid sunlight and rain e The wall hanging type is suitable for the narrow place needing be dehumidified for its small cubic e The high temperature type can be used to dehumidify the room where the primary materials of drying food chemical marine product farming product printed matter crude drug etc 2 COMPONENT I DENTI FI CATI ON Return air inlet Drainage outlet Humidistat S Control panel Dry air outlet Partial condenser 1 RU 3 WORKI NG PRI NCI PLE Main working components are WARM amp DRY AIR high efficient compressor accumulator magnetic flow control 1 f valve evaporator coil condenser coil capillary tube centrifugal fan N temperature sensor humidity sensor and electrical wiring The centrifugal fan makes wet air entering into the evaporator through air filter then the air is cooled down When the surface temperature of the evaporator is lower tha