1. 5 Carry out a function test Section 7 34 4 Operating and alarm signals General Acoustic signal Light ring Meaning Loud intermittent Flashes rapidly Local alarm signal 85 dB A Smoke or heat in 60 sec cycle in 5 sec cycle 8 short signals Flashes 8x Fault soiling Cannot be in 60 sec cycle in 8 sec cycle deactivated 2 short signals Flashes 1x Battery change due local 1 sec continuous signal 73 dB A Continously on previous event was an alarm Function test local activated by pressing the function button for at least 4 s Section 7 1 sec continuous signal 73 dB A Flashes rapidly previous event was not an alarm If using the 230 V base please follow the instructions in the corresponding Installation and User Manual Different signals are used to indicate Fault Soiling and Battery change due 1 Light ring 2 Function button Function test local activated by pressing the function button for at least 4 s Section 7 35 For wired or radio networked if equipped with optional radio module smoke alarm devices The signals generated by the smoke alarm device that triggers the alarm are as described above The other smoke alarm devices will also emit the following signals Acoustic signal Light ring Meaning Loud intermittent Alarm at networked smoke signal 85 dB A detectors smoke or heat 2 short signals o
2. 5 C or rise above 50 C less than 6 m away from hot air vents A Attention Do not mount the smoke alarm device in a vertical position on a wall This can cause it to malfunction 29 3 Installation and commissioning 1 30 Depending on the design the smoke detector will be fitted using a mounting plate only for battery operation or an optional 230 V base battery as backup power If using a 230 V base please follow the instructions in the corresponding Installation and User Manual 1 Before attaching the mounting plate cut out the prepunched slot for the cable feed using a suitable knife 2 Mount the mounting plate with the enclosed mounting material 1 Dowel 2 Mounting plate 3 Cable slot pre punched 4 Screws 5 Module interface 6 Block battery 9 V 7 Smoke alarm device 3 Use the spacers if the cable for networking several smoke alarm devices has to be surface laid Gira Product Number 2342 00 4 If necessary network several smoke alarm devices Section 3 1 5 If appropriate disable smoke detection Section 3 2 6 Insert a radio or relay module if required see corresponding Installation and User Manual 7 Connect the 9 V battery to the battery connection and insert the battery in the battery compartment 8 To prevent unauthorised removal of the smoke alarm device if necessary activate removal protection to lock the smoke alarm device on the mounting pla
3. FITT 10210 Issue 1 1 Product features e Battery operated combined smoke alarm device and thermal detector maximum and differential function for the protection of residential buildings apartments or rooms with similar purpose in accordance with DIN 14676 e Smoke detection can be disabled for rooms where the ambient conditions are not favourable for the smoke alarm device such as kitchens vapour from cooking e Automatic selftest of smoke evaluation with impurities indicator e When dark up to 12 hours delayed indication of battery replacement display or technical fault e Wired networking of up to 40 smoke detectors e Loud intermittent warning tone minimum 85 dB A e Battery replacement display e Soiling fault display e Built in button for function test e Battery compartment interlock if the smoke detector does not have a battery fitted then it is not possible to lock it into place in the mounting plate or 230 V base e 1 module interface for fitting one of the optionally available modules the network terminals remain available for use e Polarity reversal protection The unit cannot be destroyed due to incorrect battery connection e Can be retrofitted with 230 V base for Smoke alarm device Dual VdS product no 2331 02 25 2 Installation location 2 1 Example for an apartment co Le amp o odho ii E3 Minimum protection one smoke
4. alarm device in the corridor or stairwell es j Optimum protection one B smoke alarm device in each bedroom and living room Smoke detectors should ideally be installed in front of or inside bedrooms so that the occupants will be woken up if there is a fire at night For optimum performance install the smoke alarm device in the middle of the room under the ceiling If this is not possible observe a minimum distance of 50 cm to the walls The smoke detector can monitor rooms with a floor area up to a maximum of 60 m and a maximum height of 4 5 m In rooms with unfavourable conditions for smoke alarm devices such as kitchens vapour from cooking bathrooms condensation garages or very dusty areas smoke detection can be disabled in order to avoid false alarms Section 3 2 In this case only the thermal function will remain active 26 2 2 Example for a residential building Minimum protection one smoke alarm device in the corridor or stairwell of each floor Optimum protection one smoke alarm device in each bedroom living room and basement room In buildings with several storeys install at least one smoke alarm device in the corridor of each storey Use several networked smoke alarm devices in larger houses in order to cover the entire living area If smoke is detected by a smoke alarm device it triggers an alarm and activates all the connected smoke alarm devic
5. ating correctly e If no signal is emitted replace the battery 2 Then carry out the function test again If a signal is still not emitted then the smoke detector is faulty and must be replaced 3 Stop the function test by pressing the function button until the acknowledgement signal is heard If a function test is carried out on wired or radio networked smoke alarm devices all the connected smoke alarm devices emit an acoustic alarm If this does not occur please check the batteries of all the smoke alarm devices and the connections and state of the network cables 39 8 Manual suppression of signals 8 1 Suppressing the smoke detection alarm Smoke detection can be deactivated for 15 minutes e as a preventative measure to suppress an unwanted alarm when carrying out activities that generate dust sweeping a dusty room sweeping the chimney etc e to shut off the alarm if you detect non hazardous smoke To do this press the function button briefly lt 3 seconds until a short acknowledgement signal is heard and then muted again The light ring now flashes every 2 seconds i Note Thermal detection is still active 8 2 Suppressing the event display A photovoltaic cell is used to suppress the Detection head dirty and Battery change due warnings Section 4 for up to 12 h during hours of darkness This has no influence on the alarm functionality provided by the smoke detector If the Replace batter
6. es which then also emit an alarm This ensures for example that you are woken during the night in your bedroom by your networked smoke alarm device if the smoke alarm device in the basement detects smoke The same requirements apply to the installation of individual smoke alarm devices in rooms and the use of the thermal detection function as those described for installation in an apartment Section 2 1 27 2 3 Examples for particular room geometries max 15 m 28 In L shaped rooms or corridors the smoke alarm devices should be installed on the centred intersections of the two sections In the case of large L shaped rooms each section is regarded as a separate room 2 4 Unsuitable installation locations In order to avoid false alarms do not install the smoke alarm device e with active smoke detection in rooms in which a lot of steam dust or smoke occur under normal conditions Section 3 2 e near fireplaces or open fires e directly on a metal surface e less than 1 m away from air conditioning units and ventilation shafts as the air flow may prevent the smoke and or heat from reaching the alarm e at least 50 cm away from electrical ballasts low voltage transformers fluorescent lights and energy saving lights e in rooms which are higher than 4 5 m less than 30 cm away from the roof apex only in rooms where the temperature does not fall below
7. he old battery in an environmentally friendly way 37 6 Maintenance and care In order to ensure the functional reliability of the smoke alarm device for a longer period you should carry out maintenance once a month or immediately when a fault message occurs 1 Remove the smoke alarm device from the mounting plate turn counter clockwise and remove any dust 2 Wipe the smoke alarm device with a damp lint free cloth 3 Insert the smoke alarm device back into the mounting plate and turn it clockwise until it is secured 4 Carry out a function test Section 7 i Note Replace the smoke alarm device on the date specified on the device label If carrying out renovations in the room the smoke alarm device must be completely covered with the plastic cover supplied Do not forget to remove the plastic cover again after completing the renovation work A Attention The smoke alarm device must not be painted 38 7 Function test When carrying out a manual test the smoke alarm device emits a muffled signal However you should still prewarn neighbours Stay at least 50 cm away from the smoke alarm device during a function test Carry out the function test once a month and especially after long periods of absence 1 Press the function button for at least 4 seconds e If an audible signal is emitted following a short acknowledgement sound and the light ring comes on Section 4 then the smoke alarm device is oper
8. nly for wireless networks in 60 sec cycle Battery change due remote signal Function test remote signal 1 sec continuous alarm signal activated by pressing the function 73 dB A followed button for at least 4 s Section 7 by 2 s pause 5 Battery test Changing the battery The smoke detector is powered from a 9 V block battery if a 230 V base is used then only when there is an interruption to the mains power The battery test automatically checks the supply voltage at regular intervals If the battery voltage drops below a defined level the smoke alarm device signals for 30 days that the battery has to be replaced The smoke alarm device is completely functional during this period 36 To replace the battery proceed as follows 1 To do this release the locking mechanism with a screwdriver and turn the smoke detector anticlockwise 2 Remove the old battery from the compartment and disconnect the connector from the battery connection 3 Connect the new 9 V battery to the battery connection and insert the battery in the battery compartment 4 Reinsert the smoke detector into the mounting plate or 230 V base and lock in place by turning gently clockwise i Insert battery The smoke alarm device cannot be secured on the mounting plate or base unless the battery is inserted 5 Carry out a function test Only replace the old battery with a new battery of the same type Dispose of t
9. rmwald Germany 42 11 Warranty We provide a warranty as provided for by law Please send the unit postage free with a description of the defect to our central customer service via your specialised dealer Gira Giersiepen GmbH amp Co KG Service Center Dahlienstrake 12 42477 Radevormwald Deutschland 43
10. te To do this cut out the prepunched slot on the alarm housing using a suitable knife see figure The locking mechanism can now only be opened using a suitable tool 31 9 Insert the smoke alarm device into the mounting plate and secure it by turning it clockwise slightly 10 Carry out a function test i Insert battery The alarm cannot be secured on the mounting plate or base unless the battery is inserted 3 1 Wired networking of smoke alarm devices Up to 40 Gira Dual VdS smoke detectors can be connected together in a network to allow an alarm to be sounded by all the smoke detectors in a dwelling Connect the smoke alarm devices in parallel with a two conductor cable e g phone cable J Y St Y 2 x 2 x 0 6 mm When a maximum wire cross section of 1 5 mm is used the total cable length can be up to 400 m To network the smoke alarm devices proceed as follows 1 Connect the 3 pin terminal block to the cable as shown in the figure Signal_ i N fl N n 2 2 Detector 1 Detector 2 Detector n 32 2 Insert the terminal block in the corresponding holder in the mounting plate For wired networks where the 230 V base is used please refer to the corresponding Installation and User Manual It is not possible to create a wired network with modular VdS smoke detectors 3 2 Thermal detector function deactivating the smoke detector The thermal detector operates on
11. the temperature rise principle and triggers an alarm if e the rate of heating of the surrounding air exceeds the normal range e the temperature of the surroundings reaches a value between 54 C and 70 C Because it is possible to deactivate smoke detection on the Dual VdS smoke detectors they are also suitable for installation in areas where conventional smoke detectors cannot be used e in rooms where smoke detection is not appropriate such as kitchens steam from cooking and bathrooms condensation e rooms where there is a lot of dust e g garages In such cases it can make sense to deactivate the smoke detection in order to avoid false alarms In such cases the smoke detector will only function as a thermal detector Proceed as follows to deactivate smoke detection deactivation is not permitted while an alarm is ongoing 1 If necessary remove the battery as the slide switch is located on the PCB under the battery compartment 2 Break out the cover over the slide switch using a suitable tool 33 A Attention Breaking out the slide switch cover will invalidate the CE conformity of the smoke detector in accordance with EN14604 and invalidate the German Association of Property Insurers VdS Approval 3 Set both slide switches to the ON position see figure to deactivate smoke detection 4 Reconnect the 9 V block battery to the battery connector and insert the battery into the battery holder
12. y or Fault soiling message occurs at an inopportune time it can be deferred by 8 hours each day for a maximum of 7 days To do this press the function button briefly until the first signal tone is muted However remove the source of the fault as soon as possible Please contact your installer to rectify cause of the problem 40 9 Technical specifications Nominal voltage Battery Battery failure signal Optical indication Acoustic alarm indication Volume Housing dimensions Plastic material Operating temperature Storage temperature Weight without battery Degree of protection VdS approval 9VDC 9 V block alkaline type DURACELL PLUS 6LR61 Lifetime approx 5 years with radio module approx 2 years 9 V block lithium type ULTRALIFE U9VL J Lifetime approx 10 years with radio module approx 5 years 60 sec cycle 30 days Light ring red piezo primary detector Intermittent Min 85 dB A at 3 m 125 x 48 mm x H PC ASA 5 C to 50 C 20 C to 65 C Approx 120 g IP42 See rating plate on smoke detector 41 10 CE declaration of conformity Please note that CE conformance in accordance with EN14604 is only valid if smoke detection is not deactivated Section 3 2 CE 09 0786 CPD 20896 VdS approval number G209202 EN14604 2005 Smoke alarm device Dual VdS Giersiepen GmbH amp Co KG Dahlienstrake 12 42477 Radevo